Loading...
HomeMy WebLinkAboutNC0070289_Fact Sheet_20200228FACT SHEET FOR EXPEDITED PERMIT RENEWALS This form must be completed by Permit Writers for all expedited permits which do not require full Fact Sheets. Expedited permits are generally simple 100% domestics (e.g., schools, mobile home parks, etc) that can be administratively renewed with minor changes, but can include facilities with more complex issues (Special Conditions, 303(d) listed water, toxicity testing, instream monitoring, compliance concerns). Basic Information for Expedited Permit Renewals Permit Writer / Date Sydney Carpenter 8/29/2019 Permit Number NCO070289 Facility Name / Facility Class Ridgewood Farms at Stones Throw WWTP / WW-2 Basin Name / Sub -basin number Yadkin Pee -Dee / 03-07-11 Receiving Stream / HUC Caldwell Creek / 0304010503 Stream Classification in Permit C / Index: 13-17-8-5 Does permit need Daily Max NH3 limits? No — already resent Does permit need TRC limits/language? No — already resent Does permit have toxicity testing? No Does permit have Special Conditions? No Does permit have instream monitoring? Dissolved Oxygen and Temperature Is the stream impaired on 303 d list)? Yes — Impaired for Benthos Any obvious compliance concerns? Multiple enforcement cases and NOVs across a number of parameters, with both limit and monitoring violations. Any permit modifications since lastpermit? None. New expiration date 1 l /30/2023 Comments on Draft Permit ➢ Added regulatory citations. ➢ Updated eDMR footnote and Section A. (4) Changes from draft to final: • After discussions between the Central Office and Mooresville Regional Office, the following conditions have been added; o Added Section A. (3.) Engineering Assessment requiring the permittee to hire a professional, NC licensed engineer to perform a structural integrity evaluation as the facility has numerous issues that need repair, as evidenced by the Compliance Inspection on May 21, 2019. NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100 % domestic wastewaters <1.0 MOD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit NCO070289 If you are completing this form in computer use the TAB key or the up - down arrows to moue from one field to the next. To check the boxes, click your mouse on top of the bar. Otherwise, please print or type. 1. Contact Infernuatiom Owner Name Stones Throw HOA (Wayne Huntley) Facility Name Ridgewood Farms at Stones Throw Mailing Address PO Hoe 690725 City Charlotte State / Zip Code NC/28227 Telephone Number 704-607-3506 (Verlene) Fax Number 704-545-3374 e-mail Address Verlenehpl@netzero.net 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road Olde Creek Trail end of cul-de-sac City Concord State / Zip Code NC/28025 County Cabarrus 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Environmental Process Solutions PLLC Mailing Address 7000 Stinson Hartis Rd, Suite F City Indian Trail State / Zip Code NC/28079 Telephone Number (980)202-2377 Fax Number (none) e-mail Address info@cpscharlotte.com 1 d 3 Fms.0111Q NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters s l.0 MGD 4. Description of wastewater: Facility Generating Wastevrater(check all that applyk Industrial ❑ Number of Employees Commercial ❑ Number of Employees Residential E Number of Homes 1 5 School ❑ Number of Students/Staff Other ❑ Explain: Describe the source(s) of wastewater )example: subdivision, mobile home park, shopping centers, restaurants, etc.): Mobile Home Park subdivision Number of persons served: 170 S. Type of collection system N Separate )sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification numbers) 001 Is the outfall equipped with a diffuser? ❑ Yes E No 7. Name of receiving stream(s) (NEW applicants: Provide a map showing the exact location of each outfall}. Caldwell Creek which flows into Rocky River S. Frequency of Discharge: N Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: _ 9. Describe the treatment system List all installed components, including capacities, provide design removal far BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. Duplex influent pump station Narsereen Aerobic sludge holding/thickening tank with pumped decant Extended aeration Clarifier Tablet chlorination/dechlorination Post treatment reaeration to comply with effluent DO 2 of 3 FamO 11112 NPDES APPLICATION - FORM D For privately -owned treatment systems treating 100% domestic wastewaters <1.0 MOD 10. Flow Information: Treatment Plant Design floor 0.05 MOD Annual Average daily floor 0.025 MOD (for the previous 3 years) Maximum daily floor 0.264 MOD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes M No 12. Effluent Data NEW APPLfCAMS: Provide data for the parameters baled Fecal Cohforrn, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. RENEWAL APPLICANTS: Provide the highest single reading (Daily Maximum) and Monthly Average over the anst 36 months for Parameters currently in uour Permit. Mark other parameters "NIA'. Parameter Daily Maximum Monthly Average Anita of Measurement Biochemical Oxygen Demand (HODS) 48 17 mg/L Fecal Coliform 925 52 N/ 100ml Total Suspended Solids 243 68 rag/L Temperature (Summer) 30 23.5 C Temperature (Winter) 24 17.7 C pH 8.3 N/A SU 13. List all permits, construction approvals and/or applications: Type Permit Number Type Permit Number Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping (MPRSA) NPDES NCO070289 Dredge or fdi (Section 404 or CWA) PSD (CAA) Other Non -attainment program (CAA) 14. APPLICANT CERTIFICATION I certify that I am familiar with the information contained in the application and that to the beet of my knowledge and belief such information is true, complete, and accurate. 2 tea name of Signature of Apt North Carolina General Statute 143-215.6 (b)(2) states'. Any pamn who knawingly makes any Islas statement representation, or certification in any appkation, record, report plan, a other document files or requited to be mantained under Article 21 m regulations of the Environmental Management Commission imptarrentlng that Ancle, or who falsifies, tampers War, a knowingly renders inaccurate any iexceling a monilanng device or method required to be cleated or maintained under Artois 21 or regulations of the Environmental Management Canmisson implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, a by imprisonment not to exceed six months, a by both. (18 U.S.C. Secton 1001 provides a punishment by a fine of not more than $25,000 or impnsarnment not more than 5 years, or both, for a similar offense.) 3 of 3 Forni 11112 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 1 3 I NCO070289 111 12 I 19/05/21 I17 18 I C I 19 I s I 201 21I1I1II IIIIIIIII II IIIIIII I I IIIII IIIIIIIII II f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 671 70 [,J 71 ] 72 n73 I——!74 751 I I I I 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 10:02AM 19/05/21 14/02/01 Ridgewood Farms Subdivision Olde Creek Trl Exit Time/Date Permit Expiration Date Concord NC 28025 11:31AM 19/05/21 18/11/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Braden Joshua Cook/ORC/704-788-4164/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Braden Joshua Cook,7000 Stinson Hartis Rd Indian Trail NC 28079/ORC/980-202-2377/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Compliance Schedules Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date DocuSigned by: Roberto Scheller S�e,uati MRO WQ//252-946-6481/ 6/5/2019 91C2A007838943E- Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger Division of Water Quality//704-2' EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. EDocuSigned by: a� 6/5/2019 AlaccsalAFvazs . Page# NPDES yr/mo/day Inspection Type N C O070289 I11 121 19/05/21 117 18 I"I Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) - As of the date of this inspection the Division has not received a complete renewal permit application. - Diffusers in aeration basin require repair or replacement. - Bulkhead between aeration basin and sludge holding tank requires repairs. - Holes rusted through treatment unit require repairs. - Facility has two (2) outstanding civil penalties LV-2019-0309 and LV-2019-0325. Page# Permit: NCO070289 Owner - Facility: Ridgewood Farms Subdivision Inspection Date: 05/21/2019 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ 0 ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Facility is operating under permit that expired on November 30, 2018. A complete permit renewal application has not been submitted. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ 0 ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ 0 ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? 0 ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: All records reviewed were current and available for review. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Page# 3 Permit: NCO070289 Owner - Facility: Ridgewood Farms Subdivision Inspection Date: 05/21/2019 Inspection Type: Compliance Evaluation Laboratory Yes No NA NE Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ 0 ❑ Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ 0 ❑ Comment: Field Darameters are conducted under Field Certification #5695. K&W Laboratories (Certification #559) is used as the contract lab. Compliance Schedules Yes No NA NE Is there a compliance schedule for this facility? ❑ ❑ 0 ❑ Is the facility compliant with the permit and conditions for the review period? ❑ 0 ❑ ❑ Comment: Review of compliance history from April 2018 throuah March 2019 show three (3) Notice of Violations issued for the subject facility: 4/2018 NOV-2018-LV-0633, 10/2018 NOV-2018-LV-0861, 11/2018 NOV-2019-LV-0021 Review of compliance history also found two civil penaltys issued to subject facility; Case Number LV-2017-0309 issued on November 3, 2017 for the amount of $453.62 and Case Number LV-2017-0325 issued on November 28, 2017 for the amount of $703.62. Both of the civil penalties remain unpaid. Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical ❑ Are the bars adequately screening debris? 0 ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? ❑ ❑ 0 ❑ Page# 4 Permit: NCO070289 Inspection Date: 05/21/2019 Owner - Facility: Ridgewood Farms Subdivision Inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ ❑ Comment: Diffusers should be repaired or replaced in aeration basin. Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? 0 ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? ❑ ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ 0 ❑ Is the return rate acceptable (low turbulence)? M ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) ❑ ❑ ❑ Comment: Scum baffle should be cleaned out. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? 2 Is the level of chlorine residual acceptable? M ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? 0 ❑ ❑ ❑ Comment: De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ 0 ❑ Is storage appropriate for cylinders? ❑ ❑ 0 ❑ Page# 5 Permit: NCO070289 Owner - Facility: Ridgewood Farms Subdivision Inspection Date: 05/21/2019 Inspection Type: Compliance Evaluation De -chlorination Yes No NA NE # Is de -chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Comment: Are the tablets the proper size and type? M ❑ ❑ ❑ Are tablet de -chlorinators operational? M ❑ ❑ ❑ Number of tubes in use? 4 Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? M ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? 0 ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? 0 ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: At time of inspection sample storage was recorded at 4 degrees Celsius. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? 0 ❑ ❑ ❑ Comment: At time of inspection effluent was clear with few visible suspended soids. Aerobic Digester Yes No NA NE Is the capacity adequate? ❑ ❑ 0 ❑ Is the mixing adequate? ❑ ❑ 0 ❑ Page# 6 Permit: NCO070289 Owner - Facility: Ridgewood Farms Subdivision Inspection Date: 05/21/2019 Inspection Type: Compliance Evaluation Aerobic Digester Yes No NA NE Is the site free of excessive foaming in the tank? 0 ❑ ❑ ❑ # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? ❑ 0 ❑ ❑ Comment: TOD of bulkhead between diaester and aeration basin has rusted out and bulkhead ma collapse if digester is pumped out. Rusted out holes in bulkhead makes it ineffective to waste and dewater sludge at this facility. Holes rusted through end of treatment unit allows waste to exit treatment unit via holes during high flow. Rusted out holes in treatment plant that allows untreated wastewater to excape is considered a by-pass of treatment and a violation of your NPDES permit. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: At time of inspection facility appeared to be well operated. It was noted that rusted out holes in treatment plant and issues with diffusers in areation basin hamper plant performance and the ability of operator to effectively and efficiently operate WWTP at peak performance. Page# 7 ROY COOPER [atwer,r9ur K41CHAEL S. REGAN Secrl_vr ary LINDA CULPEPPER Dfr{> a NORTH CAROUNA Environmental Quallrr Certified Mail # 7017 2620 0000 6788 5702 Return Receipt Requested June 05, 2019 Mr. Wayne Huntley Stones Throw Homeowners Association Post Office Box 690725 Charlotte, NC 28227 SUBJECT: Compliance Inspection Report Ridgewood Farms Subdivision NPDES WW Permit No. NCO070289 Cabarrus County Dear Mr. Huntly: The North Carolina Division of Water Resources conducted an inspection of the Ridgewood Farms Subdivision on May 21, 2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0070289. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". Please respond in writing to this office within 30 days of your receipt of this letter regarding your plans or measures to be taken to address the following issues: • As of the date of the subject inspection, the Division has not received a complete permit renewal application. • Diffusers in aeration basin require repair or replacement. • Bulkhead between aeration basin and sludge holding tank requires repairs. • Holes rusted through treatment unit allowing wastewater to by-pass treatment require repairs. • Facility has two (2) outstanding civil penalties LV-2017-0309 and LV-2019-0325. This Office should be contacted as soon as possible regarding these civil penalties. NorthCaro -na Depart meRtofErr:raeraerts Qua!rty I DbAsvn of Water Resoumes Wo+oresv �_- R fl•xna; Offs e 1 610 East :�r'ter avenue, Suite W1 I IVooresv �.e, North Csrohns 25115 a iaapz 704.663-1699 If you should have any questions, please do not hesitate to contact Roberto Scheller with the Water Quality Regional Operations Section in the Mooresville Regional Office at 704-663-1699 or via email at roberto.scheller@ncdenr.gov. Sincerely, DocuAASigned by: �i A14CC681AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Mooresville Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File Laserfiche NorthCaro- na Depart meRtof Erv:rorr ents� I D:vsoRof Water Resomres Wo+oresv eR fl•ona;Off: ce1610 East Z�-rster Ave nue,SLteW1IIV. ooresv;e,North£rero-,Pa28115 aura.., 7f�4.663-16'6� October 17, 2019 NCDEQ-DWR Water Quality Permitting Section 1617 Mail Services Center Raleigh, NC 27699-1617 Attn: Sydney Carpenter RE: NPDES Permit NCO070289 - Ridgewood Farms at Stones Throw WWTP Dear Ms. Carpenter, My husband and I own a home in the Ridgewood Farms development in Cabarrus County, NC. This neighborhood was developed in the late 1980's and early 1990's by FW Huntley Construction Company, Inc., of which the owner and president is Mr. Franklin Wayne Huntley. Our home was built in 1989. We have been the current owners since October, 2015. At the time our home was constructed, it was connected by Mr. Huntley to a wastewater treatment plant in the adjoining neighborhood of Stones Throw, which he also developed. Our home is one of approximately 100 homes in three neighborhoods connected to this system. We recently learned that Mr. Huntley and Stones Throw Homeowners Association have submitted an application to renew the permit to continue operating the wastewater treatment plant servicing our home. As one of the many residents reliant on this system for access to sewer services, we are very concerned about what might happen to our homes and property values in the event that the permit was not renewed. As part of your review of the permit application, please consider the fate of all of us residents who would be affected if the permit were denied and services discontinued. What other options would be available? Would our homes be condemned? None of us want to risk losing their homes over this. What can be done to insure that won't occur? Our hope is that the concerns expressed above will help guide your decisions about operation of the wastewater treatment plant serving our communities. Awareness of our connection to an aging system has been the cause of significant stress for my family, and many of our neighbors. We are hopeful that there will be an opportunity to work together to come up with an acceptable solution for any problems that may exist with the system, and to keep it operational and compliant for many years to come. Sincerely, (:�A M "k4r Sharon Hartz Resident, Ridgewood Farms 416 Mammoth Oaks Drive Concord, NC 28025 (980)258-0794 Independent Tribune Advertising Affidavit PO Box 968 Hickory, NC 28603 NCDEO/DWR ATTN: WREN THEDFORD 1617 MAIL SERVICE CENTER RALEIGH, NC 27699-1617 Account Number 3611028 Date September 18, 2019 Date Category Description Ad Number Ad Size 09/18/2019 Legal Notices PURiC NO110E North Carolina Enreanme�nnl Maeyemeot Canm¢vo_ 1617 Mail Service Center Raleigh, NC 27699-1617 Notice of Ndentto Issue a WM Wariewater Permit The North Carolina Environmental Management Commission pmposts to issue a NPOES wastewater discharge permit to the personis) listed below. Written comments regarding NR proposed permit will be accepted until 30 days after the publish date of this entice. The Director of the RC Divio lion of Water Resources (TWR) may hold a public hearing should there be a siphicam degree of public interest Please mal comments and/or infor• mation requests to DWR at the above address. Interested persons may wit R the DWR at 512 N. Wbbury Street, Raleigh, NC to review information on file. Additional information on 110 ppeermita and this notice may be found on nor wehsite: hh�J/dMAC._W/Z Vdivisions/walerre oum /water-murces-oermNsiwastewaM-0rancVnpdes•waAewater/oudir notices, or br calling (919) 707-3601. Shares Throw HOA of Caherms Courdy has applied for renewal of NCO070289 fro gldgewood Tama at Stones Thmw WWTP; Cahams Courty discharging treated wastewater to Caldwell Creek;Yad&lphae Dee River Basin River Basin. Rdfnh: SepOmha 18, 2019. Public Notice North Carolina Environmental Management Comi 0000597303 2 x 24 L Publisher of Independent Tribune Cabarrus County Before the undersigned, a Notary Public oL k"ei;-County, North Carolina, duly commissioned, qualified, and authorized by law to administer oaths, in said County and State; that he/she is authorized to make this affidavit and swom statement; that the notice or other legal advertisement, a copy of which is attached hereto, was published in the Independent Tribune on the following dates: 09/18/2019 and that the said newspaper in which such notice, or legal advertisement was published, was a newspaper meeting all the requirements and qualifications of Section 1-597 of the General Statutes of North Carolina. Assistant Bookkeeper Newspaper reference: 0000597303 Sworn to and subscribed before me, this —Leday of 4Z 2019 . �saaaan narrtr MC K/N Nota�Pu �AgY pi �a p �G C My Commission expires: ��= i�iO.Z�Cr (/ B �• 2 THIS IS NOT A BILL. PLEASE PAY FROM INVOICE. THANK YOU 'rrt 0/4 Cu ` From: Scheller, Roberto To: Caroenter, Sydney Subject: RE: DRAFT Permit Conditions for Stones Throw WWTP (NC0070289) Date: Monday, January 27, 2020 4:52:08 PM Attachments: imaae001.a_na Miss Sydney: Comments on Subject Draft Permit NC0070289. In Draft Permit page 3 of 7 and 4 of 7 under Footnotes: 1. [see A. (5.)]. Need to change 3 to 5., the additional Engineering Assessment and Sewer Moratorium has pushed the Electronic Reporting forward two spaces. Thankyou Roberto L. Scheller NC Dept. of Environmental Quality Division of Water Resources Water Quality Regional Operations Section 610 E. Center Ave., Sute 301 Mooresville, NC 28115 Ph:704-235-2204 Fax:704-663-6040 From: Carpenter, Sydney Sent: Tuesday, January 21, 2020 4:52 PM To: Scheller, Roberto <roberto.scheller@ncdenr.gov>; Basinger, Corey <corey.basinger@ncdenr.gov>; Hennessy, John <john.hennessy@ncdenr.gov>; Denard, Derek <derek.denard@ncdenr.gov> Subject: DRAFT Permit Conditions for Stones Throw WWTP (NC0070289) Hello, I have a draft permit for Ridgewood Farms at Stones Throw WWTP (NC0070289) ready for y'alls review. As I understood it, we wanted to include special conditions in their permit renewal which would require an engineering assessment and initiate a tap moratorium. Please see the attached draft permit for the conditions I have drafted and let me know what y'all think! Apologies for the delay in getting this to y'all for review. Thanks, Sydney Carpenter Environmental Specialist 1 Compliance and Expedited Permitting Branch Division of Water Resources NC Department of Environmental Quality Office: 919-707-3712 Sydney. carpenter(cDncdenr.gov 1617 Mail Service Center Raleigh, NC 27699-1617 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties.