HomeMy WebLinkAbout20200237 Ver 1_4-P05187_Permit Package Buffer & Surface Water_20200203_20200214CONTRACT SHEET
1 OF XX
PROJECT NO. P-05187
ENGINEERING DIVISION
PROJECT NO. P05187
CONTRACT 2011-067
WATER ............ U?9...............L.F. X $1.50 = $............ A............
SEWER .................................... L.F. X$1.50=$...........................
RDWY......................................L.F. X $1.50 = $ ............................
TOTAL.............................................................. $............ .............
❑ ROADWAY TO BE PRIVATELY INSPECTED
DATE FEES RECEIVED BY CITY OF GREENSBORO ..............................
ALAMANCE CHURCH ROAD IMPROVEMENTS.
BUFFEr& SURFACE I WATER IMPACTS PERMIT
INDEX OF SHEETS
TYPICAL SECTIONS................................................................
F-1 TO F-3
PLAN/PROFILE SHEETS - ALAMANCE CHURCH ROAD .... F-4 TO F-12
PLAN/PROFILE SHEET - BRISTOL ROAD ........................................
F-13
PLAN/PROFILE SHEET - WILLOW ROAD ..........................................
F-14
PROFILE SHEET.................................................................................
F-15
PIPE PROFILE SHEETS .......................................................
F-16 TO F-20
WET POND DETAILS...........................................................
F-21 TO F-23
RETAINING WALL ENVELOPES .........................................
F-24 TO F-25
PAVEMENT MARKING PLANS .....................................
PMP-1 TO PMP-7
EROSION CONTROL PLANS AND DETAILS ....................
EC-1 TO EC-5
TRAFFIC CONTROL PLANS AND DETAILS ................
TMP-1 TO TMP-6
SIGNING PLANS .......................................................
SIGN-1 TO SIGN-14
-J
1
DISTURBED
AREA = 11.0
ACRES
BEFORE YOU DIG!
CONTACT ONE —CALL CENTER
1-800-632-4949 OR'811'
STANDARD TOPO SYMBOLS
CITY OF GREENSBORO
ENGINEERING DESIGN DIVISION
Existing Manhole 118" (labeled)
O
Proposed Manhole 1/8'.........................._......_...
•
Telecommunications Manhole 1/8" (labeled) ..................
Q
Exist Curb Inlet MtT-5/64" ...............................
Prop. Curb Inlet S/32"-516 .
I�
Telephone Booth 3116"-S116".................................
Exist. Telephone Or Power Pole 3132.........................
4
Prop. Telephone Or Power Pole 3132..........................
City Of Greensboro Signal Pole MT (labeled) ..............
® COG
Guy Wire Mt2"..............................................
v
Exist. Hydrant 3132"........................................
Pro,. Hydrant 3/32.... ......................................
water Valve 3132" (labeled)
Taf lc Engineering Signal Box &M.........................
[I COG
Gas Valve 3/32'.............................................
Grate or Drop Inlet (D.I.) 3/32............................
110
Double Gate or Drop Inlet (2GI.D.I.) 3132..............................
Right Of Way Monument 3/32.... ..............................
m
Iron Pipe 3I64".............................................
o EIP
Meter 5/64"
EleNical Outlet 5AM" (labeled) ..... .......... ............
b ELECT.
Telecommunications Box Or Pedestal 5/64" (labeled).........
ID
Exist. Pads, Taveae Point 7/64" (labeled) ...............
¢PTP
18" Or Lees Tree 1M"(Iabeled).............................
Over 20" Tree 5/1 C' Ilabeletl)
20'
Shrub 5/32".................................................
Clean Out 1/16"-1/32" (labeled)
®CO.
Light POIe 3/32" (labeled) ..............................
0 L'GT
Wheelchair Ramp (City Of Greensboro SW. "18)..............
Control Of Access Line 5/16"................................
ExieL Water Line (labeled) .......................
yy
Prop. Water Line (labeled)... ...... ........... ...... ........
W _
Exist. Sanitary Sewer (labeled) .............................
ss
Prop. Sanitary Sewer (labeled) ..............................
�=
Exist. Right Of Way .. ................ .- ................ ....
Proposed Margin
Easement llabeletll..........................................
-
Temporary C-1—ion Easement .............................
Exist. Dirt Streat................ .- ................ ......
E lal. Payment.....
Exist cure pabeled
Exist. Curb & Gutter (1abaled)& ..... .........
I.........
Prop. C8 Gutter (shaded &labeled).d).....................
urb
Survey Line._ ...................
SlopeLine...................................................—
Center Line .................................................
Exist. Stone Sewer (labeled).......... ................... ...
�..�...�..�
Prop. Stone Sewer (labeled)......_........._ ..............
�.. �.. �..�
Gas Line (labeled) ..........................................
G
Transmission Line & Tower ...................................
Underground Telecommunication Cable (labeled
Underground Power Line ......................................
rence pabeled)
Railroad..........................................
hind, (Pmp. Solid & EAaL Broken
/ \
,Q d Box Gulvert (Prop. Solid & ExisL Broken) ...................
O \ Guard HedgeRa011.................._..............................
s r Bushes(labeled).................................. �h
WootlsLine ..................................................
Exist. House .............................................. 1-SBD
VICINITY MAP SCALE: 1 °= 50Dr 2001
BID DATE: AUGUST 29, 2019 EZ,, ,,t,lD,,i,,(..._.. Sad...._.215_.... , , , _
5DD 25D 0 5DD Erosion Control Device (COG SM. No. 2158432).............
-L-
PI Sta 29+47.07
DELTA = 45" 40' 53.5" (LT)
D=7a 50'55.5"
L = 582.02'
T = 307.48'
R = 730.00'
CH = 566.73'
VF\,6S\�>66
\\
N\I\S
>6
EAR�IyEN BE � S S
S\ �S\�60\ \ \\) \ \ \ \ \
I-EOP 0S9\ \\ 6F +S
\ �B\�N\✓'69PDE DITSH5ED\PE\C�CUTCH\ECCERALI 1
\T C\
C_
>OP>✓_ -\-W
�—
.�� sF".���-`�� �1/�I�r�.i��_ d271 � ��1\\ VI�I � i�i� i��/�bYi�lil►w+�� ,I ,
It N 1 .2 US
W
__---_�---- J,
48"
DELTA = 16a 08' 19.6" (LT) \�
D=6°21'58.3"+
L = 253.51'
T = 127.60' \
R=900.00' SITE 3
CH = 252.67'
PI = 30+2
EL = 737.
VC = 300'
K = 254.9
1
3f+35.00
742.55'
VC = 130'
K = 75.0
-L- ALAM 4 tCE CHURCH RD
E —
MITIGABLE
IMPACTS ZONE 1
DENOTES
SURFACix
IMPACTS N
WATER
REVISIONS
PI = 36+25.00
EL = 758,58'
VC = 130
K = 473.0
TYPE
CONTRACT
ICONTRACTORI
AS -BUILT
I AUTH. DATE
I BENCH MARKS NAD 83 / NAD 88
ROADWAY
2011-067
9122114
NORTHING
EASTING
ELEV. (F
SEWER
834457.6481
1770772.1457
733.1370
L66200
835057.9400
1772487.0400
735.6000
WATER
2011-067
10/30/17
830877.8756
1779665.1632
761.2500
SIDEWALK
2011-067
9/22/14
831387.0350
1778431.6022
784.7506
DETAIL 1 CONTRACT SHEET
SPECIAL BACK OF CURB CUT DITCH
(NOT TO SCALE) # OF #
GROUND?
F — — SENSITIVE INFORMAL
Not to be copied or
FROM STA
.28+80 TO STA.30+25 -L- LT distributed without the
FROM STA. 33+20 TO STA. 34+00 -L- LT
FROM STA. 36+75 TO STA. 37+50 -L- LT express written
DETAIL 5 permission of the City
SPECIAL LATERAL BASE DITCH of Greensboro.
I Nee Scale) 'O�4 MUST �y.�
Natural�SPJZ 1l ITY PaO
CENTER
O Min. D=1.0 Ff. ¢ W
O B=Z.O F.
Ar
FROM STA. 30+75 TO STA. 31+90 -L- LT = m
O \ -* BEFORE YOU DIG!
NOTE: ALL PUBLIC °°1--ABD�°�9O '8
W H STORM TO BE INTALLED city Of ror
P w PER NCDOT SPECS (TYP) I ��
wx, NOTE: STORM SEWER `DGw77e 7" 73-`
GUOT —If 73-'c
ASBUILTS REQUIRED. DDG'D°"` 73-`
COG Wat r - ]3-c
SUBMIT TO THE Ta^k"
'Z ENGINEERING DEPT. Door 5t 3
a CALL (336)373-2052
U NOTE: PRIOR TO PUBLIC NPDES
STORM INSTALLATION, General Permit
CONTACT ANDY VINCENT Applies
(336)373-2336 TO SCHEDULE
AN INSPECTOR
\
DISTURBED AREA =
11.0 Acres
GIs DISCLAIMER
Objects on this map shown
with a dotted linestyle were
not surveyed, they were
compiled by photogrammetric
methods, available on the
Geographic Information
System (GIS) software used
by the City of Greensboro.
o��?�?�EESS��N9Ns°o
iv SEAL
$ 026971 f
o°o2AQOFE5` , 5 0o
e v@ SEAL �� a
035663 s a
oo
m
000
oo�0p°° a000�oo �000
39
4O ROADWAY IMPROVEMENTS
JOB NO. P- 05187
CITY OF GREENSBORO
ENGINEERING DIVISION
rFI
DESIGNED 7/10/2017 BY MBF
CONST. SURVEY BY ---
ALAMANCE CHURCH ROAD WIDENING
MARTIN LUTHER KING JR. DRIVE TO
GREENSBORO CITY LIMIT
SHEET NO.
CHECKED BY MBL
3 OF 17
SCALE: 1" = 40' HORIZ 1" = 4' VERT
RIPARIAN BUFFER IMPACTS SUMMARY
IMPACTS
Site
No.
Station
(From/To)
Structure
Size / Type
TYPE
ALLOWABLE
MITIGABLE
BUFFER
REPLACEMENT
ROAD
CROSSING
BRIDGE
PARALLEL
IMPACT
ZONE 1
(ft)
ZONE 2
(ft)
TOTAL
(ft)
ZONE 1
(ft)
ZONE 2
(ft)
TOTAL
(ft)
ZONE 1
(ft)
ZONE 2
(ft)
1
21+40 / 23+45
Temp. Const. Esmt.
x
1821
1821
2
24+00 / 25+80
Temp. Const. Esmt.
x
1751
1751
3
30+90 / 31+30
2@36" RCP
x
333
333
4
72+70 / 74+30
Wet Det. Pond
x
4039
4039
4
72+60 / 74+20
Roadway Crossing
x
4917
1424
6341
TOTALS*:
8489
5463
13952
333
0
333
0
0
NOTES:
1. Site No. 4 Road Crossing Impact = 88 LF
2018 Feb
WETLAND AND SURACE WATER IMPACTS SUMMARY
IMPACTSWETLAND IMPACTS SURFACE WATER
Site
No.
Station
(From/To)
Structure
Size / Type
Permanent
Fill In
Wetlands
(ac)
Temp.
Fill In
Wetlands
(ac)
Excavation
in
Wetlands
(ac)
Mechanized
Clearing
in Wetlands
(ac)
Hand
Clearing
in
Wetlands
(ac)
Permanent
SW
impacts
(ac)
Temp.
SW
impacts
(ac)
Existing
Channel
Impacts
Permanent
(ft)
Existing
Channel
Impacts
Temp.
(ft)
Natural
Stream
Design
(ft)
1
22+87
15" RCP
< 0.01
10
2
25+67
30" RCP
< 0.01
10
3
31+08
2@36" RCP
< 0.01
15
4
73+50
42" RCP
< 0.01
< 0.01
50
33
TOTALS:
< 0.01
1 < 0.01
85
33
0
*Rounded totals are sum of actual impacts
NOTES:
SITE 1 - PERM = 80 SQ FT
SITE 2 - PERM = 80 SQ FT
SITE 3 - PERM = 123 SQ FT
SITE 4 - PERM = 149 SQ FT / TEMP = 100 SQ FT
Revised 2018 Feb