Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20001177 Ver 1_COMPLETE FILE_20000913
7 F- ENGINEERING CONSULTING SERVICES, LTD. Geotechnical • Construction Materials • Environmental September 5, 2000 Mr. John Domey North Carolina Department of Environment and Natural Resources Division of Water Quality Wetland/401 Unit 1621 Mail Service Center Raleigh, North Carolina 27699-1621 Subject: Revised Pre-Construction Notification Application Proposed Commercial Building Winston-Salem, Forsyth County, North Carolina ECS Project G-3434F Dear Mr. Dorney: ?r• Mon Please find seven copies of the revised Pre-Construction Notification Application for the above referenced site. Both Mr. Todd St. John and Ms. Jennifer Frye are familiar with the site. The site is approximately 10 acres in area and is located on Westbrook Plaza Drive in Winston-Salem (Figure 1). The site is to be developed with a three story commercial building and associated parking areas. A 401 Water Quality Certification was issued for the project on February 22, 2000 (DWQ Project # 000253). A copy of this certification is included with this package. Tributaries of Little Creek cross the site. Approximately 294 linear feet of intermittent stream channel will be impacted by the construction of a stormwater pond. The stream will be diverted around the pond in order to avoid treating off-site stormwater in the pond. The intermittent stream channel will be graded during construction of the pond. The stream currently enters the site through a 30" RCP. The stream was designated as intermittent by Ms. Jennifer Frye of the North Carolina Division of Water Quality in October 1999. Approximately 147.5 linear feet of perennial stream channel will be impacted by the construction of a roadway/dam. In order to minimize the impact to the perennial portion of the stream, the roadway/dam have been combined. The proposed development is illustrated on the attached Grading and Erosion Control Plan prepared by Stimmel Associates, P.A. We are requesting a 401 Water Quality Certification for the impact to 294 linear feet of intermittent stream channel and 147.5 linear feet of perennial stream channel. As the impact to the perennial portion of the stream channel is less than 150 linear feet, we are not including a mitigation plan with this request. A stormwater management plan has been designed to remove 85 % total suspended solids. The intermittent stream on the site is very low quality. It is our opinion, that the stormwater pond will be 5-C Dundas Circle, Greensboro, NC 27407 • (336) 856-7150 • Fax (336) 856-7160 Offices: Aberdeen, MD • Atlanta, GA • Austin, TX • Baltimore, MD • Chantilly, VA • Charlotte, NC • Chicago, IL • Frederick, MD • Fredericksburg, VA • Greensboro, NC • Greenville, SC • Norfolk, VA • Raleigh, NC • Richmond, VA • Roanoke, VA • Williamsburg, VA • Wilmington, NC Section 401 Permitting Proposed Commercial Building ECS Project G-3434F more effective in preserving water quality. The stormwater pond design specifications have been forwarded to Mr. Todd St. John for his review. Please feel free to contact me at (336) 856-7150 if you have any questions concerning this request or if additional information is required. Thank you in advance for your timely consideration of this matter. Sincerely, ENGINEERING CONSULTING SERVICES, LTD. 6 _: . - /??_S Denise M. Poulos, LSS Principal Scientist Attachment: Pre-Construction Notification Application $475.00 Application Fee 2 DWQ ID: _ CORPS ACTION ID: NATIONWIDE PERMIT REQUESTED (PROVIDE NATIONWIDE PERMIT #) 14,26 PRE-CONSTRUCTION NOTIFICATION APPLICATION FOR NATIONWIDE PERMITS THAT REQUIRE: 1. NOTIFICATION TO THE CORPS OF ENGINEERS 2. APPLICATION FOR SECTION 401 CERTIFICATION 3. COORDINATION WITH THE NC DIVISION OF COASTAL MANAGEMENT SEND THE ORIGINAL AND (1) COPY OF THIS COMPLETED FORM TO THE APPROPRIATE FIELD OFFICE OF THE CORPS OF ENGINEERS (SEE AGENCY ADDRESSES SHEET). SEVEN (7) COPIES MUST BE SENT TO THE NC DIVISION OF WATER QUALITY ATTN• JOHN DORNEY, 4401 REEDY CREEK ROAD, RALEIGH, NC 27607. PLEASE PRINT OR TYPE. 1. OWNER'S NAME: Mr. Scott Boldt, KDA Financial 2. MAILING ADDRESS: 350 Franklin Road SUBDIVISION NAME CITY: Marietta STATE: Geor is ZIP CODE: 30067 PROJECT LOCATION ADDRESS, INCLUDING SUBDIVISION NAME (IF DIFFERENT FROM MAILING ADDRESS ABOVE): The ro'ect is located on Westbrook Plaza Drive in Winston-Salem. 3. TELEPHONE NUMBER: (HOME) _ (WORK) (770) 421-1532 4. IF APPLICABLE: AGENT'S NAME OR RESPONSIBLE CORPORATE OFFICIAL, ADDRESS, PHONE NUMBER: Denise M Poulos Engineering Consulting Services Ltd 5-C Dundas Circle Greensboro NC 27407. (336) 85.6-7150 5. LOCATION OF WORK (PROVIDE A MAP, PREFERABLY A COPY OF USGS TOPOGRAPHIC MAP OR AERIAL PHOTOGRAPHY WITH SCALE): COUNTY: Forsyth - NEAREST TOWN: Winston-Salem SPECIFIC LOCATION (INCLUDE ROAD NUMBERS, LANDMARKS, ETC.) The site is located on Westbrook Plaza Drive in Winston-Salem. 6. IMPACTED OR NEAREST STREAM/RIVER: Little Creek/Muddy Creek RIVER BASIN: Yadkin/PeeDee 7. (a) IS PROJECT LOCATED NEAR WATER CLASSIFIED AS TROUT, TIDAL SALTWATER, (SA), HIGH QUALITY WATERS (HQW), OUTSTANDING RESOURCE WATERS (ORW), WATER SUPPLY (WS-1 OR WS-II)? YES ? NO X IF YES, EXPLAIN: LOCATED (b) IS THE PROJECT NORTH CAROLINA O COASTAL MANAGEMENT AREA OF ENVIRONMENTAL CONCERN (AEC)? YES ? NO ? (c) IF THE PROJECT IS COASTAL COUNTIES), WHAT ISD THE LAND USE PLAN (LOUP) DESIGNATION?FOR LIST OF C 8. (a) HAVE ANY SECTION 404 PERMITS BEEN PREVIOUSLY REQUESTED FOR USE ON THIS PROJECT? YES X NO IF YES, PROVIDE ACTION I.D. NUMBER OF PREVIOUS PERMIT AND ANY ADDITIONAL INFORMATION (INCLUDE PHOTOCOPY OF 401 CERTIFICATION): 200020694 (b) ARE ADDITIONAL PERMIT REQUESTS EXPECTED FOR THIS PROPERTY IN THE FUTURE? YES ? NO X IF YES, DESCRIBE ANTICIPATED WORK: 9. (a) ESTIMATED TOTAL NUMBERS OF ACRES IN TRACT OF LAND: 10 Acres (b) ESTIMATED TOTAL NUMBER OF ACRES OF WETLANDS LOCATED ON PROJECT SITE: A tributary of Little Creek crosses the site There are no wetlands present on the site. 10. (a) NUMBER OF ACRES OF WETLANDS IMPACTED BY THE PROPOSED PROJECT BY: FILLING: _ EXCAVATION: FLOODING: _ OTHER: DRAINAGE: TOTAL ACRES TO BE IMPACTED: NA (b) (1) STREAM CHANNEL TO BE IMPACTED BY THE PROPOSED PROJECT (IF RELOCATED, PROVIDE DISTANCE BOTH BEFORE AND AFTER RELOCATION: LENGTH BEFORE: _ FT AFTER: - FT WIDTH BEFORE (based on normal high water contours): _ FT AVERAGE DEPTH BEFORE: _ FT AFTER: _ FT (b) (2) STREAM CHANNEL IMPACTS WILL RESULT FROM: (CHECK ALL THAT APPLY) OPEN CHANNEL RELOCATION: _ PLACEMENT OF PIPE IN CHANNEL: X CHANNEL EXCAVATION: _ CONSTRUCTION OF A DAM/FLOODING: X OTHER: Diversion 11. IF CONSTRUCTION OF A POND IS PROPOSED, WHAT IS THE SIZE OF THE WATERSHED DRAINING TO THE POND? 30.3 acres WHAT IS THE EXPECTED POND SURFACE AREA? 0.5 acres 12. DESCRIPTION OF PROPOSED WORK INCLUDING DISCUSSION OF TYPE OF MECHANICAL EQUIPMENT TO BE USED? (ATTACH PLANS; 81/2 BY I I DRAWINGS ONLY) The site is to be developed with a three stow office building and parking lots The building and parking lots will be constructed in high ground Only a stormwater pond and a roadway will impact the stream located on the site Truck loaders excavators backhoes bulldozers etc will be used to develop the site. 13. PURPOSE OF PROPOSED WORK: The site is to be developed with a three story office building and a stormwater pond. 14. STATE REASONS WHY IT IS BELIEVED THAT THIS ACTIVITY MUST BE CARRIED OUT IN WETLANDS (INCLUDE ANY MEASURES TAKEN TO MINIMIZE WETLAND IMPACTS) Due to the topography of the site a stormwater pond will be constructed near the eastern boundary. This will im act approximately 294 If of intermittent stream channel due to diversion and fill. To minimize impacts the dam/access road have been combined The dam/road will impact approximately 147.5 If of perennial stream channel. 15. YOU ARE REQUIRED TO CONTACT THE US FISH AND WILDLIFE SERVICE AND/OR NATIONAL MARINE FISHERIES SERVICE REGARDING THE PRESENCE OF ANY FEDERALLY LISTED OR PROPOSED FOR LISTING ENDANGERED OR THREATENED SPECIES OR CRITICAL HABITAT IN THE PERMIT AREA THAT MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED: 16. YOU ARE REQUIRED TO CONTACT THE STATE HISTORIC PRESERVATION OFFICER (SHPO) REGARDING THE PRESENCE OF HISTORIC PROPERTIES IN THE PERMIT AREA WHICH MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED _. Feb -07-00 04p;a35P P_ 01 rcm-tMGIMEERIMG CCMSULTIMG SRVS LTD +3368567160 1-163 A. 002/002 F-346 ». DOES THE PROJECT INVOLVE AN EXPENDITURE OF PUBLIC FUNDS OR THE USE OF PUBLIC (STATE) LAND? YES ? NO X (IF NO, GO TO 16) (a) IF YES, DOES THE PROJECT REQUIRE PREPARATION OF AN ENVIRONMENTAL DOCUMENT PURSUANT TO THE REQUIREMENTS OF THENORTH CAROLINA ENVIRONMENTAL POLICY ACT? YES ? NO ? (b) IF YES, HAS THE DOCUMENT BEEN REVIEWED THROUGH THE NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CLEARINGHOUSE YES ? NO ? IF ANSWER 17b IS YES, THEN SUBMIT APPROPRIATE DOCUMENTATION FROM THE STATE CLEARINGHOUSE WITH THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT, QUESTIONS REGARDING THE STATE CLEARINGHOUSE REVIEW PROCESS SHOULD BE DIRECTED TO MS. CHRYS BAGGETT, DIRECTOR STATE CLEARINGHOUSE, NORTH CAROLINA DEPARTMENT OF ADMIMSTRATTON, 116 WEST JONES STREET, RALEIGH, NORTH CAROLINA 27603-8003. TELEPHONE (919) 733-6369. 18 THE FOLLOWING ITEMS SHOULD BE INCLUDED WITH THIS APPLICATION IF PROPOSED ACTIVITY INVOLVES THE DISCHARGE OF EXCAVATED OF FILL MATERIAL INTO WETLANDS: (a) WETLAND DELINEATION MAP SHOWING ALL WETLANDS, STREAMS, LAKES, AND PONDS ON THE PROPERTY (FOR NATIONWIDE PERMIT NUMBERS 14, 18, 21, 26, 29, AND 38). ALL STREAM (IINIT:RMIT'I ENT AND PERMANENT) ON THE PROPERTY MUST BE SHOWN ON THE MAP. MAP SCALES SHOULD BE 1 INCH EQUALS SO FEET OF I INCH EQUALS 100 FEET OF THEIR EQUIVALENT. (b) IF AVAILABLE, REPRESENTATIVE PHOTOGRAPH OF WETLANDS TO BE IMPACTED BY PROR=. (c) IF DELINEATION WAS PERFORMED BY A CONSULTANT, INCLUDE ALL DATA SHEETS RELEVANT TO THE PLACEMENT OF THE DELINEATION LINE. (d) ATTACH A COPY OF THE STORMWATER MANAGEMENT PLAN IF REQUIRED. (c) WHAT IS LAND USE OF SURROUNDING PROPERTY? RcsidentiaUcommomial (I) IF APPLICABLE, WHAT IS PROPOSED METHOD OF SEWAGE DISPOSAL? Sanitary sewer svstem• SIGNED AND DATED AGENT AUTHORIZATION LETTER, IF APPLICABLE. NOTE: WETLANDS OR WATERS OF TEE US MAY NOT BE IMPACTED PRIOR TO: 1. ISSUANCE OF A SECTION 404 CORPS OF ENGINEERS PERMIT. 2. EITHER THE ISSUANCE OR WAIVER OF A 401 DIVISION OF WATER QUALITY CERTIFICATION, AND 3. (IN' THE TWENTY COASTAL COUNTIES ONLY), A LETTER FROM THE NORTH LIMA DIVISION OF COASTAL MANAGEMENT STATING THE PROPOSED t TY LS CONSISTENT WITH THE NORTH CAROLINA COASTAL MANAGEMENT n oa SIGNATURE DATE (AGENT'S SIGNATURE VALID ONLY IF AUTHORIZATION LETTER FROM THE OWNER IS PROVIDED). Feb-28-00 05:31P State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director 16 WA 1 Pka • NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES February 22, 2000 I?orsyth County mvQ Project # 000253 APPROVAL of 401 Water Quality Certification with Additional Conditions Scutt Boldt, KDA Financial 330 Franklin Road Marietta. GA 30067 P.02 Dear Mr. Boldt: You have our approval, in accordance with the attached conditions and those listed below, to construct a pond and a road crossing which will impact a total of 452 feet of stream channel for the purpose of commercial construction in Forsyth County, as you described in your application received by the Division of Water Quality on February 11, 2000. After reviewing your application, we have decided that this action is covered by General Water Quality Certification Numbers 3103 and 3108. This certification allows you to use Nationwide Permit Numbers 14 and 26 when the Corps of Engineers issues it. In addition, you should get any other federal, state or local permits before you go ahead with your project including (but not limited to) Sediment and Erosion Control, Coastal Stormwater, Non-Discharge and Water Supply Water shed regulations. This approval will expire when the accompanying 404 or CAMA permit expires unless otherwise specified in the General Certification. This approval is only valid for the purpose and design that you described in your application. If you change your project, you must notify us and you may be required to send us a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter and is thereby responsible for complying with all conditions. If total wetland fills for this project (now or in the future) exceed one acre, compensatory mitigation may he required as described in 15A NCAC ZH .0506 (h) (6) and (7). For this approval to be valid you must follow the conditions below and those listed in the attached certification. 1. An additional condition is that a final, written stormwater management plan shall be approved by this Office before the impacts specified in this Certification occur. The stormwater management plan must include plans and specifications for stormwater management facilities designed to remove 85% TSS according to the most recent version of the NC DENR Sturmwater Best Management Practices Manual. Also, before any permanent building is occupied at the subject site, the facilities, as approved by this Office, shall be constructed and operational, and the stortnwater management plan, as approved by this Office, shall be implemented. If you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter 1508 of the North Carolina General Statutes to the Office of Administrative Hearings, P,O. Box 27447, Raleigh, N.C. 276 1 1-7447. This certification and its conditions arc final and binding unless you ask for a hearing. This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone John Dorney at 919-733-9646. Attachment cc: Corps of Engineers Raleigh Field Office Winston-Salem DWQ Regional Office Denis Poulos, Engineering Consulting Services, 5-C Dundas Circle, Greensboro. NC 27407 File Copy Central Files 000253 \,? r. i ; •il y?,i t ' .'?riii _ r Leo S? ro ? _ ?'Y?`(? a ? \` (lti '?• ? ICJ ???'? • . \ ? 'ilr I'"?• •.? 1? J,, ?? ? ? JAI `v Jam,. • ,,, ?• ? `? `???1 ,' Ll?? ,.,? •, /,• a ?; 6. IV" jam. .. y : SOURCE: CIS FIGURE 1 USGS TOPOGRAPHIC MAP, LTD SITE LOCATION MAP WINSTON-SALEM WEST, NC PROPOSED COMMERCIAL QUADRANGLE, DATED 1950 AND BUILDING REVISED 1994 ENGINEERING WINSTON-SALEM, NC SCALE: I"= 2,000' CONSULTING ECS PROJECT G-3434F SERVICES,LTD DATA FORM ROUTINE WETLA24•D DETERMII` ATION 1987 COE Wetlands Delineation Manual) Project/Site: Approximate 12 Acre Tract - I-40 @ Stratford Road Project Yo: Date: October 4, 1999 Applicant/Owner: KDA Financial County: Forsyth Investigators: Denise M. Poulos/ ECS, LTD. G-3434 State: North Carolina Plot ID: Data Point I Do Normal Circumstances exist on the site? Yes No Community ID: Is the site significantly disturbed (Atypical Situation:)? Yes No Transect ID: Is the area a potential Problem Area? Yes No Field Location: Near SB-20 (If needed, explain on the reverse side) VEGETATION Dominant Plant Species (Latin/Common) Stratum Indicator Plant Species (Latin/Common) Stratum Indicator atiens s I p. mp Touch-me-not Herb FACW on radicans d d i T en r co ox Poison ivy onica i L Herb FAC cera jap on Japanese honeysuckle dif li t V i Vine FAC- a o un s ro it Muscadine grape Vine FAC Percent of Dominant Species that are OBL, FACW or FAC: FAC Neutral: (excluding FAC-) 100% Numeric Index: Remarks: The dominant vegetation is hydro hytic. HYDROLOGY Recorded Data (Describe in Remarks): Stream, Lake or Tide Gauge Aerial Photographs Other X No Recorded Data Field Observations Depth of Surface Water: 0" Depth to Free Water in Pit: >12" Depth to Saturated Soil: 6" Remarks: Wetland Hydrology Indicators Primary Indicators Inundated X Saturated in Upper 12 Inches Water Marks Drift Lines X Sediment Deposits Drainage Patterns in Wetlands Secondary Indicators Oxidized Root Channels in Upper 12 Inches Water-Stained Leaves Local Soil Survey Data FAC-Neutral Test Other (Explain in Remarks) 11 Wetland hydrology indicators were observed. Page 1 of 2 ' W erform) SOIL S 11 Map Unit Name (Series and Phase): Pacolet fine sandy loam Mapped Hydric Inclusion? Yes No Map Symbol: PaC Drainage Class: Well Drained Field Observations Confirm vlapped Type: Yes No Taxonomy (Subgroup): Typic hapludults Profile Descri tion Depth (inches) Horizon Matrix Color Nitinsell Moist) Mottle Color (Munsell Moist) Mottle Abundance/Contrast Texture, Concretions, Structure, etc. 0-12 1OYR 6/6 Loamy sand Hvdric Soil Indicators: Concretions Histosol High Organic Content in Surface Layer in Sandy Soils Histic Epipedon Organic Streaking in Sandy Soils Sulfidic Odor Listed on Local Hydric Soils List Aquic Moisture Regime Listed on National Hydric Soils List Reducing Conditions Gleved or Low Chroma Colors Other (Explain in Remarks) Remarks: Hydric soil indicators were not observed. I 11 WETLAND DETERIN LNATION Hydrophytic Vegetation Present? Yes No Is the Sampling Point within the Wetland? Yes No Wetland Hydrology Present? Yes No Hvdric Soils Present? Yes Yo Remarks: The wetland criteria were not present. The sampling point is not located within a wetland. Page 2 of 2 ENGINEERING CONSULTING SERVICES, LTD. Geotechnical - Construction Materials - Environmental September 5, 2000 Mr hn borney r= N?off! Department of Environment and Natural Resources Division of Water Quality Qs;:. V1jtland/461'Unit lj4`1 Mil-,rvice Center ., . Raleigh, 4:1 h Carolina 27699-1621 - Subject: Revised Pre-Construction Notification Application Proposed Commercial Building Winston-Salem, Forsyth County, North Carolina ECS Project G-3434F Dear Mr. Dorney: Please find seven copies of the revised Pre-Construction Notification Application for the above referenced site. Both Mr. Todd St. John and Ms. Jennifer Frye are familiar with the site. The site is approximately 10 acres in area and is located on Westbrook Plaza Drive in Winston-Salem (Figure 1). The site is to be developed with a three story commercial building and associated parking areas. A 401 Water Quality Certification was issued for the project on February 22, 2000 (DWQ Project # 000253). A copy of this certification is included with this package. Tributaries of Little Creek cross the site. Approximately 294 linear feet of intermittent stream channel will be impacted by the construction of a stormwater pond. The stream will be diverted around the pond in order to avoid treating off-site stormwater in the pond. The intermittent stream channel will be graded during construction of the pond. The stream currently enters the site through a 30" RCP. The stream was designated as intermittent by Ms. Jennifer Frye of the North Carolina Division of Water Quality in October 1999. Approximately 147.5 linear feet of perennial stream channel will be impacted by the construction of a roadway/dam. In order to minimize the impact to the perennial portion of the stream, the roadway/dam have been combined. The proposed development is illustrated on the attached Grading and Erosion Control Plan prepared by Stimmel Associates, P.A. We are requesting a 401 Water Quality Certification for the, impact to 294 linear feet of intermittent stream channel and 147.5 linear feet of perennial stream channel. As the impact to the perennial portion of the stream channel is less than 150 linear feet, we are not including a mitigation plan with this request. A stormwater management plan has been designed to remove 85 % total suspended solids. The intermittent stream on the site is very low quality. It is our opinion, that the stormwater pond will be 5-C Dundas Circle, Greensboro, NC 27407 - (336) 856-7150 - Fax (336) 856-7160 Offices: Aberdeen, MD - Atlanta, GA - Austin, TX - Baltimore, MD - Chantilly, VA - Charlotte, NC - Chicago, IL - Frederick, MD - Fredericksburg, VA - Greensboro, NC - Greenville, SC - Norfolk, VA - Raleigh, NC - Richmond, VA - Roanoke, VA - Williamsburg, VA - Wilmington, NC ` Section 401 Permitting Proposed Commercial Building ECS Project G-3434F more effective in preserving water quality. The stormwater pond design specifications have been forwarded to Mr. Todd St. John for his review. Please feel free to contact me at (336) 856-7150 if you have any questions concerning this request or if additional information is required. Thank you in advance for your timely consideration of this matter. Sincerely, ENGINEERING CONSULTING SERVICES, LTD. GG? Cenise Poulos, LSS Principal Scientist Attachment: Pre-Construction Notification Application $475.00 Application Fee 2 DWQ ID: _ CORPS ACTION ID: NATIONWIDE PERMIT REQUESTED (PROVIDE NATIONWIDE PERMIT #) 14,26 PRE-CONSTRUCTION NOTIFICATION APPLICATION FOR NATIONWIDE PERMITS THAT REQUIRE: 1. NOTIFICATION TO THE CORPS OF ENGINEERS 2. APPLICATION FOR SECTION 401 CERTIFICATION 3. COORDINATION WITH THE NC DIVISION OF COASTAL MANAGEMENT SEND THE ORIGINAL AND (1) COPY OF THIS COMPLETED FORM TO THE APPROPRIATE FIELD OFFICE OF THE CORPS OF ENGINEERS (SEE AGENCY ADDRESSES SHEET). SEVEN (7) COPIES MUST BE SENT TO THE NC DIVISION OF WATER QUALITY ATTN• JOHN DORNEY, 4401 REEDY CREEK ROAD, RALEIGH, NC 27607. PLEASE PRINT OR TYPE. 1. OWNER'S NAME: Mr. Scott Boldt, KDA Financial 2. MAILING ADDRESS: 350 Franklin Road SUBDIVISION NAME CITY: Marietta STATE: Georgia ZIP CODE: 30067 PROJECT LOCATION ADDRESS, INCLUDING SUBDIVISION NAME (IF DIFFERENT FROM MAILING ADDRESS ABOVE): The protect is located on Westbrook Plaza Drive in Winston-Salem. 3. TELEPHONE NUMBER: (HOME) _ (WORK) (770) 421-1532 4. IF APPLICABLE: AGENT'S NAME OR RESPONSIBLE CORPORATE OFFICIAL, ADDRESS, PHONE NUMBER: Denise M Poulos Engineering Consulting Services Ltd 5-C Dundas Circle Greensboro NC 27407, (336) 856-7150 5. LOCATION OF WORK (PROVIDE A MAP, PREFERABLY A COPY OF USGS TOPOGRAPHIC MAP OR AERIAL PHOTOGRAPHY WITH SCALE): COUNTY: Forsyth - NEAREST TOWN: Winston-Salem SPECIFIC LOCATION (INCLUDE ROAD NUMBERS, LANDMARKS, ETC.) The site is located on Westbrook Plaza Drive in Winston-Salem. 6. IMPACTED OR NEAREST STREAM/RIVER: Little Creek/Muddy Creek RIVER BASIN: Yadkin/PeeDee 7. (a) IS PROJECT LOCATED NEAR WATER CLASSIFIED AS TROUT, TIDAL SALTWATER, (SA), HIGH QUALITY WATERS (HQW), OUTSTANDING RESOURCE WATERS (ORW), WATER SUPPLY (WS-I OR WS-II)? YES ? NO X IF YES, EXPLAIN: (b) IS THE PROJECT LOCATED WITHIN A NORTH CAROLINA DIVISION OF COASTAL MANAGEMENT AREA OF ENVIRONMENTAL CONCERN (AEC)? YES ? NO ? (c) IF THE PROJECT IS LOCATED WITHIN A COASTAL COUNTY (SEE PAGE 7 FOR LIST OF COASTAL COUNTIES), WHAT IS THE LAND USE PLAN (LUP) DESIGNATION? 8. (a) HAVE ANY SECTION 404 PERMITS BEEN PREVIOUSLY REQUESTED FOR USE ON THIS PROJECT? YES X NO IF YES, PROVIDE ACTION I.D. NUMBER OF PREVIOUS PERMIT AND ANY ADDITIONAL INFORMATION (INCLUDE PHOTOCOPY OF 401 CERTIFICATION): 200020694 (b) ARE ADDITIONAL PERMIT REQUESTS EXPECTED FOR THIS PROPERTY IN THE FUTURE? YES ? NO X IF YES, DESCRIBE ANTICIPATED WORK: 9. (a) ESTIMATED TOTAL NUMBERS OF ACRES IN TRACT OF LAND: 10 Acres (b) ESTIMATED TOTAL NUMBER OF ACRES OF WETLANDS LOCATED ON PROJECT SITE: A tributary of Little Creek crosses the site There are no wetlands present on the site. 10. (a) NUMBER OF ACRES OF WETLANDS IMPACTED BY THE PROPOSED PROJECT BY: FILLING: _ EXCAVATION: FLOODING: OTHER: DRAINAGE: TOTAL ACRES TO BE IMPACTED: NA (b) (1) STREAM CHANNEL TO BE IMPACTED BY THE PROPOSED PROJECT (IF RELOCATED, PROVIDE DISTANCE BOTH BEFORE AND AFTER RELOCATION: LENGTH BEFORE: _ FT AFTER: _ FT WIDTH BEFORE (based on normal high water contours):_ FT AVERAGE DEPTH BEFORE: _ FT AFTER: _ FT (b) (2) STREAM CHANNEL IMPACTS WILL RESULT FROM: (CHECK ALL THAT APPLY) OPEN CHANNEL RELOCATION: _ PLACEMENT OF PIPE IN CHANNEL: X CHANNEL EXCAVATION: _ CONSTRUCTION OF A DAM/FLOODING: X OTHER: Diversion 11. IF CONSTRUCTION OF A POND IS PROPOSED, WHAT IS THE SIZE OF THE WATERSHED DRAINING TO THE POND? 30.3 acres WHAT IS THE EXPECTED POND SURFACE AREA? 0.5 acres 12. DESCRIPTION OF PROPOSED WORK INCLUDING DISCUSSION OF TYPE OF MECHANICAL EQUIPMENT TO BE USED? (ATTACH PLANS; 81/2 BY 1 I DRAWINGS ONLY) The site is to be developed with a three story office building and parking lots. The building and parking lots will be constructed in high ground Only a stormwater pond and a roadway will impact the stream located on the site Truck loaders excavators backhoes bulldozers etc will be used to develop the site. 13. PURPOSE OF PROPOSED WORK: The site is to be developed with a three storyyoffiice building and a stormwater pond. 14. STATE REASONS WHY IT IS BELIEVED THAT THIS ACTIVITY MUST BE CARRIED OUT IN WETLANDS (INCLUDE ANY MEASURES TAKEN TO MINIMIZE WETLAND IMPACTS) Due to the topography of the site a stormwater pond will be constructed near the eastern boundary. This will impact approximately 294 If of intermittent stream channel due to diversion and fill. To minimize impacts the dam/access road have been combined The dam/road will impact approximately 147.5 If of perennial stream channel. 15. YOU ARE REQUIRED TO CONTACT THE US FISH AND WILDLIFE SERVICE AND/OR NATIONAL MARINE FISHERIES SERVICE REGARDING THE PRESENCE OF ANY FEDERALLY LISTED OR PROPOSED FOR LISTING ENDANGERED OR THREATENED SPECIES OR CRITICAL HABITAT IN THE PERMIT AREA THAT MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED: 16. YOU ARE REQUIRED TO CONTACT THE STATE HISTORIC PRESERVATION OFFICER (SHPO) REGARDING THE PRESENCE OF HISTORIC PROPERTIES IN THE PERMIT AREA WHICH MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED _. Feb-07-00 04:35P P_Ol rla-vi-cuuu ii:coaa rr m-tMGINEERIAG CCNSULTIMG SRVS LTD •13368567160 T-163 P.002J002 F-346 ». DOES THE PROJECT INVOLVE AN EXPENDITURE OF PUBLIC FU14DS OR THE USE OF PUBLIC (STATE) LAND? YES ? NO X (IF NO, GO TO 16) (a) IF YES, DOES THE PROJECT REQUIRE PREPARATION OF AN ENVIRONMENTAL DOCUMENT PURSUANT TO THE REQUIREMENTS OF THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT? YES ? NO ? (b) IF YES, HAS THE DOCUMENT BEEN REVIEWED THROUGH THE NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CLEARINGHOUSE YES ? NO ? IF ANSWER 17b IS YES, THEN SUBMIT APPROPRIATE DOCUMENTATION FROM THE STATE CLEARINGHOUSE WITH THE NORTH CAROLINA E14VIRONMEENTAL POLICY ACT. QUESTIONS REGARDING THE STATE CLEARINGHOUSE REVIEW PROCESS SHOULD BE DIRECTED TO MS. CHRYS BAGGETT, DIRECTOR STATE CLEARINGHOUSE, NORTH CAROLINA DEPARTMENT OF ADMINISTRATION, 116 WEST JONES STREET, RALEIGH, NORTH CAROLINA 27603-8003. TELEPHONE (919) 733-6369. 18THE FOLLOWING ITEMS SHOULD BE INCLUDED WITH THIS APPLICATION IF PROPOSED ACTIVITY INVOLVES THE DISCHARGE OF EXCAVATED OF FILL MATERIAL INTO WETLANDS: (a) WETLAND DELINEATION MAP SHOWING ALL WETLANDS, STREAMS, LAKES, AND PONDS ON THE PROPERTY (FOR NATIONWIDE PERMIT NUMBERS 14, 18, 21, 26, 29, AND 33). ALL STREAM (INTERMITTENT AND PERMANENT) ON THE PROPERTY MUST BE SHOWN ON THE MAP. MAP SCALES SHOULD BE 1 INCH EQUALS 50 FEET OF I INCH EQUALS 100 FEET OF THEIR EQUIVALENT. (b) IF AVAILABLE, REPRESENTATIVE PHOTOGRAPH OF WETLANDS TO BE IMPACTED BY PROJECT. (c) IF DELINEATION WAS PERFORMED BY A CONSULTANT, INCLUDE ALL DATA SHEETS RELEVANT TO THE PLACEMENT OF THE DELINEATION LINE. (d) ATTACH A COPY OF TIIE STORMWATER MANAGEMENT PLAN IF REQUIRED. (c) WHAT IS LAND USE OF SURROUNDING PROPERTY" RokcatfaUcammorvial (1) IF APPLICABLE, WHAT IS PROPOSED METHOD OF SEWAGE DISPOSAL? Sani sewer system. SIGNED AND DATED AGENT AUTHORIZATION LETTER, IF APPLICABLE. ' NOTE: WETLANDS OR WATERS OF THE US MAY NOT BE IMPACTED PRIOR TO: I. ISSUANCE OF A SECTION 404 CORPS OF ENGINEERS PERMIT, 2. EITHER THE ISSUANCE OR WAIVER OF A 401 DIVISION OF WATER QUALITY CERTIFICATION, AND 3. (IN' THE TWENTY COASTAL COUNTIES ONLY), A LETTER FROM THE NORTH C LIMA DIVISION OF COASTAL MANAGEMENT STATING THE PROPOSED F TY IS CONSISTENT WITH THE NORTH CAROLINA COASTAL MANAGEMENT all 100 SIGNATURE DATE (AGENT'S SIGNATURE VALID ONLY IF AUTHORIZATION LETTER FROM THE OWNER IS PROVIDED). Feb-28-00 05:31P State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director ? 1 • a AM. NCDENR NORTH CAROL-INA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES February 22, 2000 Forsyth County DWQ Project t# 000253 APPROVAL of 401 Water Quality Certification with Additional Conditions Scutt Buldt, KDA Financial 350 Franklin Road Marietta, GA 30067 P-02 Dear Mr. Buldt: You have our approval, in accordance with the attached conditions and those listed below, to construct a pond and a road crossing which will impact a total of 452 feet of stream channel for the purpose of commercial construction in Forsyth County, as you described in your application received by the Division of Water Quality on February 11. 2000. After reviewing your application, we have decided that this action is covered by General Water Quality Certification Numbers 3103 and 3 108. This certification allows you to use Nationwide Permit Numbers 14 and 26 when the Corps of Engineers issues it. In addition, you should get any other federal, state or local permits before you go ahead with your project including (but not limited to) Sediment and Erosion Control, Coastal Stormwater, Non-Discharge and Water Supply Water shell regulations. This approval will expire when the accompanying 404 or CAMA permit expires unless otherwise specified in the General Certification. This approval is only valid for the purpose and design that you described in your application. If you change your project, you must notify us and you may be required to send us a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter and is thereby responsible for complying with all conditions. If total wetland fills for this project (now or in the future) exceed one acre, compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to be valid you must follow the conditions below and those listed in the attached certification. I. An additional condition is that a final, written stormwater management plan shall be approved by this Office before the impacts specified in this Certification occur. The stormwater management plan must include plans and specifications for stormwater management facilities designed to remove 85% TSS according to the most recent version of the NC DENR Starm?vater Best Management Practices Manual. Also, before any permanent building is occupied at the subject site, the facilities, as approved by this Office, shall be constructed and operational, and the stormwater management plan, as approved by this Office, shall be implemented. If you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter 150B of the North Carolina General Statutes to the Office of Administrative Hearings, P.O. Box 27447, Raleigh, N.C. 27611-7447. This certification and its conditions arc final and binding unless you ask for a hearing. This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone John Dorney at 919-733-9646. Attachment cc: Corps of Engineers Raleigh Field Office Winston-Salem DWQ Regional Office Denis Poulos, Engineering Consulting Services, 5-C Dundas Circle. Greensboro File Copy Central Files NC 27407 000253 •_ ? ??? .?- .... 1?• V ?'t ? Ili I opt 19 fli ---I ,? fir' ? I i ?? ??• _1i?' ? ? l??'¦ ?? ? ! '\ ??'(/j? 85? / ?.,? ??? ?)\ _ ???/? ? °a. X11 I I? 1I1/C??\ ? 9 ??• ? •? ? J ?? pi -?1 ? I i,? ? ... I \ ?_. !`I'.?' ,•, ? . /.-ice-/ ' ? (? ?.??,,?? .\?... /'`1r•??i (fir '//' ? ?' I _- . ^ (:'? 1;0 o SOURCE: C FIGURE 1 USGS TOPOGRAPHIC MAP, 's LTD SITE LOCATION MAP WINSTON-SALEM WEST, NC PROPOSED COMMERCIAL QUADRANGLE, DATED 1950 AND ENGINEERING BUILDING NC WINSTON-SALEM REVISED 1994 SCALE: I"= 2 000' CONSULTING , ECS PROJECT G-3434F , SERVICES,LTD DATA FORM ROUTINE WETLAND DETERMINATION (1987 COE Wetlands Delineation Manual) Project/Site: Approximate 12 Acre Tract - I-30 @ Stratford Road Project No: Date: October 4, 1999 Applicant/Owner: KDA Financial County: Forsyth Investigators: Denise :V1. Poulos/ ECS, LTD. G-3434 State: North Carolina Plot ID: Data Point I Do Normal Circumstances exist on the site? Yes No Community ID: Is the site significantly disturbed (Atypical Situation:)? Yes No Transect ID: Is the area a potential Problem Area.' Yes Yo Field Location: Near SB-20 (If needed, explain on the reverse side) Dominant Plant Species (Latin/Common) Stratum Indicator Plant Species (Latin/Common) Stratum Indicator atiens s I p. mp Touch-me-not Herb FACW dendron radicans i T co ox Poison ivy Herb FAC onica a ja i L p cer on Japanese honeysuckle difolia t Viti Vine FAC- un s ro Muscadine grape Vine FAC Percent of Dominant Species that are OBL, FACW or FAC: FAC Neutral: (excluding FAC-) 100% Numeric Index: Remarks: The dominant vegetation is hydro hytic. HYDROLOGY Recorded Data (Describe in Remarks): Wetland Hydrology Indicators Stream, Lake or Tide Gauge Primary Indicators Aerial Photographs Inundated Other X Saturated in Upper 12 Inches Water Marks X No Recorded Data Drift Lines X Sediment Deposits Field Observations Drainage Patterns in Wetlands Secondary Indicators Depth of Surface Water: 0" Oxidized Root Channels in Upper 12 Inches Water-Stained Leaves Depth to Free Water in Pit: >12" Local Soil Survey Data FAC-Neutral Test Depth to Saturated Soil: 6" Other (Explain in Remarks) Remarks: Wetland hydrology indicators were observed. Page 1 of 2 (Wetform) ,SU 1LJ flap Unit Name (Series and Phase): Pacolet fine sandy loam flapped Hydric Inclusion? Yes No flap Symbol: PaC Drainage Class: Well Drained N Field Observations Confirm Mapped Type: Yes o Taxonomy (Subgroup): Typic hapludults Profile Description Depth Matrix Color Mottle Color Mottle (inches) Horizon (Munsell Moist) (Nlunsell Moist) Abundance/Contrast Texture, Concretions, Structure, etc. 0-12 10YR 6/6 Loamy sand I Hydric Soil Indicators: Histosol Concretions High Organic Content in Surface Layer in Sandy Soils Histic Epipedon anic Streaking in Sandy Soils Or Sulfidic Odor g Listed on Local Hydric Soils List Aquic Moisture Regime Listed on National Hydric Soils List Reducing Conditions Gleved or Low Chroma Colors Other (Explain in Remarks) Remarks: Hydric soil indicators were not observed. i WETLAND DETERENATION Hydrophytic Vegetation Present? Yes No Wetland Hydrology Present? Yes No Hydric Soils Present? Yes No Is the Sampling Point within the Wetland? Yes No Remarks: The wetland criteria were not present. The sampling point is not located within a wetland. (Wefform) Page 2 of 2 Zr h,? ENGINEERING CONSULTING SERVICES, LTD. Geotechnical - Construction Materials - Environmental C= MBohn borney NQ4h Carolina Department of Environment and Natural Resources Division of Water Quality W Zand/40-1 Unit 1 Marl 0orvice Center r, t Raleigh,"Ninth Carolina 27699-1621 t . Subject: Revised Pre-Construction Notification Application Proposed Commercial Building Winston-Salem, Forsyth County, North Carolina ECS Project G-3434F Dear Mr. Dorney: September 5, 2000 Please find seven copies of the revised Pre-Construction Notification Application for the above referenced site. Both Mr. Todd St. John and Ms. Jennifer Frye are familiar with the site. The site is approximately 10 acres in area and is located on Westbrook Plaza Drive in Winston-Salem (Figure 1). The site is to be developed with a three story commercial building and associated parking areas. A 401 Water Quality Certification was issued for the project on February 22, 2000 (DWQ Project # 000253). A copy of this certification is included with this package. Tributaries of Little Creek cross the site. Approximately 294 linear feet of intermittent stream channel will be impacted by the construction of a stormwater pond. The stream will be diverted around the pond in order to avoid treating off-site stormwater in the pond. The intermittent stream channel will be graded during construction of the pond. The stream currently enters the site through a 30" RCP. The stream was designated as intermittent by Ms. Jennifer Frye of the North Carolina Division of Water Quality in October 1999. Approximately 147.5 linear feet of perennial stream channel will be impacted by the construction of a roadway/dam. In order to minimize the impact to the perennial portion of the stream, the roadway/dam have been combined. The proposed development is illustrated on the attached Grading and Erosion Control Plan prepared by Stimmel Associates, P.A. We are requesting a 401 Water Quality Certification for the impact to 294 linear feet of intermittent stream channel and 147.5 linear feet of perennial stream channel. As the impact to the perennial portion of the stream channel is less than 150 linear feet, we are not including a mitigation plan with this request. A stormwater management plan has been designed to remove 85 % total suspended solids. The intermittent stream on the site is very low quality. It is our opinion, that the stormwater pond will be 5-C Dundas Circle, Greensboro, NC 27407 - (336) 856-7150 - Fax (336) 856-7160 Offices: Aberdeen, MD - Atlanta, GA - Austin, TX - Baltimore, MD - Chantilly, VA - Charlotte, NC - Chicago, IL - Frederick, MD - Fredericksburg, VA - Greensboro, NC - Greenville, SC - Norfolk, VA - Raleigh, NC - Richmond, VA - Roanoke, VA - Williamsburg, VA - Wilmington, NC Section 401 Permitting Proposed Commercial Building ECS Project G-3434F more effective in preserving water quality. The stormwater pond design specifications have been forwarded to Mr. Todd St. John for his review. Please feel free to contact me at (336) 856-7150 if you have any questions concerning this request or if additional information is required. Thank you in advance for your timely consideration of this matter. Sincerely, ENGINEERING CONSULTING SERVICES, LTD. enise M. Poulos, LSS Principal Scientist Attachment: Pre-Construction Notification Application $475.00 Application Fee 2 DWQ ID: _ CORPS ACTION ID: NATIONWIDE PERMIT REQUESTED (PROVIDE NATIONWIDE PERMIT #) 14,26 PRE-CONSTRUCTION NOTIFICATION APPLICATION FOR NATIONWIDE PERMITS THAT REQUIRE: 1. NOTIFICATION TO THE CORPS OF ENGINEERS 2. APPLICATION FOR SECTION 401 CERTIFICATION 3. COORDINATION WITH THE NC DIVISION OF COASTAL MANAGEMENT SEND THE ORIGINAL AND (1) COPY OF THIS COMPLETED FORM TO THE APPROPRIATE FIELD OFFICE OF THE CORPS OF ENGINEERS (SEE AGENCY ADDRESSES SHEET). SEVEN (7) COPIES MUST BE SENT TO THE NC DIVISION OF WATER QUALITY ATTN• JOHN DORNEY, 4401 REEDY CREEK ROAD, RALEIGH, NC 27607. PLEASE PRINT OR TYPE. 1. OWNER'S NAME: Mr. Scott Boldt, KDA Financial 2. MAILING ADDRESS: 350 Franklin Road SUBDIVISION NAME CITY: Marietta STATE: Geor is ZIP CODE: 30067 PROJECT LOCATION ADDRESS, INCLUDING SUBDIVISION NAME (IF DIFFERENT FROM MAILING ADDRESS ABOVE): The proiect is located on Westbrook Plaza Drive in Winston-Salem. 3. TELEPHONE NUMBER: (HOME) _ (WORK) (770) 421-1532 4. IF APPLICABLE: AGENT'S NAME OR RESPONSIBLE CORPORATE OFFICIAL, ADDRESS, PHONE NUMBER: Denise M Poulos Engineering Consulting Services Ltd 5-C Dundas Circle Greensboro NC 27407, (336) 856-7150 5. LOCATION OF WORK (PROVIDE A MAP, PREFERABLY A COPY OF USGS TOPOGRAPHIC MAP OR AERIAL PHOTOGRAPHY WITH SCALE): COUNTY: Forsyth - NEAREST TOWN: Winston-Salem SPECIFIC LOCATION (INCLUDE ROAD NUMBERS, LANDMARKS, ETC.) The site is located on Westbrook Plaza Drive in Winston-Salem. 6. IMPACTED OR NEAREST STREAM/RIVER: Little Creek/Muddy Creek RIVER BASIN: Yadkin/PeeDee 7. (a) IS PROJECT LOCATED NEAR WATER CLASSIFIED AS TROUT, TIDAL SALTWATER, (SA), HIGH QUALITY WATERS (HQW), OUTSTANDING RESOURCE WATERS (ORW), WATER SUPPLY (WS-I OR WS-II)? YES ? NO X IF YES, EXPLAIN: (b) IS THE PROJECT LOCATED WITHIN A NORTH CAROLINA DIVISION OF COASTAL MANAGEMENT AREA OF ENVIRONMENTAL CONCERN (AEC)? YES ? NO ? (c) IF THE PROJECT IS LOCATED WITHIN A COASTAL COUNTY (SEE PAGE 7 FOR LIST OF COASTAL COUNTIES), WHAT IS THE LAND USE PLAN (LUP) DESIGNATION? 8. (a) HAVE ANY SECTION 404 PERMITS BEEN PREVIOUSLY REQUESTED FOR USE ON THIS PROJECT? YES X NO IF YES, PROVIDE ACTION I.D. NUMBER OF PREVIOUS PERMIT AND ANY ADDITIONAL INFORMATION (INCLUDE PHOTOCOPY OF 401 CERTIFICATION): 200020694 (b) ARE ADDITIONAL PERMIT REQUESTS EXPECTED FOR THIS PROPERTY IN THE FUTURE? YES ? NO X IF YES, DESCRIBE ANTICIPATED WORK: (a) ESTIMATED TOTAL NUMBERS OF ACRES IN TRACT OF LAND: 10 Acres (b) ESTIMATED TOTAL NUMBER OF ACRES OF WETLANDS LOCATED ON PROJECT SITE: A tributary of Little Creek crosses the site There are no wetlands present on the site. 10. (a) NUMBER OF ACRES OF WETLANDS IMPACTED BY THE PROPOSED PROJECT BY: FILLING: _ EXCAVATION: FLOODING: OTHER: DRAINAGE : TOTAL ACRES TO BE IMPACTED: NA (b) (1) STREAM CHANNEL TO BE IMPACTED BY THE PROPOSED PROJECT (IF RELOCATED, PROVIDE DISTANCE BOTH BEFORE AND AFTER RELOCATION: LENGTH BEFORE: _ FT AFTER: - FT WIDTH BEFORE (based on normal high water contours):_ FT AVERAGE DEPTH BEFORE: _ FT AFTER: - FT (b) (2) STREAM CHANNEL IMPACTS WILL RESULT FROM: (CHECK ALL THAT APPLY) OPEN CHANNEL RELOCATION: _ PLACEMENT OF PIPE IN CHANNEL: X CHANNEL EXCAVATION: CONSTRUCTION OF A DAM/FLOODING: X OTHER: Diversion I l. IF CONSTRUCTION OF A POND IS PROPOSED, WHAT IS THE SIZE OF THE WATERSHED DRAINING TO THE POND? 30.3 acres WHAT IS THE EXPECTED POND SURFACE AREA? 0.5 acres 12. DESCRIPTION OF PROPOSED WORK INCLUDING DISCUSSION OF TYPE OF MECHANICAL EQUIPMENT TO BE USED? (ATTACH PLANS; 81/2 BY 1 1 DRAWINGS ONLY) The site is to be developed with a three story office building and parking lots. The building and parking lots will be constructed in high ground Only a stormwater pond and a roadway will impact the stream located on the site Truck loaders excavators backhoes bulldozers etc. will be used to develop the site. 13. PURPOSE OF PROPOSED WORK: The site is to be developed with a three story office building and a stormwater pond. 14. STATE REASONS WHY IT IS BELIEVED THAT THIS ACTIVITY MUST BE CARRIED OUT IN WETLANDS (INCLUDE ANY MEASURES TAKEN TO MINIMIZE WETLAND IMPACTS) Due to the topography of the site a stormwater pond will be constructed near the eastern boundary. This will impact approximately 294 If of intermittent stream channel due to diversion and fill. To minimize impacts the dam/access road have been combined The dam/road will impact approximately 147.5 If of perennial stream channel. 15. YOU ARE REQUIRED TO CONTACT THE US FISH AND WILDLIFE SERVICE AND/OR NATIONAL MARINE FISHERIES SERVICE REGARDING THE PRESENCE OF ANY FEDERALLY LISTED OR PROPOSED FOR LISTING ENDANGERED OR THREATENED SPECIES OR CRITICAL HABITAT IN THE PERMIT AREA THAT MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED: 16. YOU ARE REQUIRED TO CONTACT THE STATE HISTORIC PRESERVATION OFFICER (SHPO) REGARDING THE PRESENCE OF HISTORIC PROPERTIES IN THE PERMIT AREA WHICH MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED _. Feb-07-00 04:35P P_01 rvo-ur-cuuu 1I:[D2a tr=-tMGINEERinG 0fSULTIMG SRVS LTD +3368567160 T-163 P.0021002 F-346 ». DOES THE PROJECT INVOLVE AN EXPENDITURE OF PUBLIC FUNDS OR THE USE OF PUBLIC (STATE) LAND? YES ? NO X (IF NO, GO TO 16) (a) IF YES, DOES THE PROJECT REQUIRE PREPARATION OF AN ENVIRONMENTAL DOCUMENT PURSUANT TO THE REQUIREMENTS OF THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT? YES ? NO ? (b) IF YES, HAS THE DOCUMENT BEEN REVIEWED THROUGH THE NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CLEARINGHOUSE YES ? NO ? IF ANSWER 17b IS YES, THEN SUBMIT APPROPRIATE DOCUMENTATION FROM THE STATE CLEARINGHOUSE WITH THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT, QUESTIONS REGARDING THE STATE CLEARINGHOUSE REVIEW PROCESS SHOULD BE DIRECTED TO MS. CHRYS BAGGETT, DIRECTOR STATE CLEARINGHOUSE, NORTH CAROLINA DEPARTMENT OF ADMINISTRATTON, 116 WEST JONES STREET, RALEIGH, NORTH CAROLINA 27603-8003, TELEPHONE (919) 733-6369. 18 THE FOLLOWING ITEMS SHOULD BE INCLUDED WITH THIS APPLICATION IF PROPOSED ACTIVITY INVOLVES THE DISCHARGE OF EXCAVATED OF FILL MATERIAL INTO WETLANDS: (a) WETLAND DELINEATION MAP SHOWING ALL WETLANDS, STREAMS, LAKES, AND PONDS ON THE PROPERTY (FOR NATIONWIDE PERMIT NUMBERS 14,13,21,26,29, AND 38). ALL STREAM (INTERMITTENT AND PERMANENT) ON THE PROPERTY MUST BE SHOWN ON THE MAP. MAP SCALES SHOULD BE 1 INCH EQUALS 50 FEET OF I INCH EQUALS 100 FEET OF THEIR EQUIVALENT. (b) IF AVAILABLE, REPRESENTATIVE PHOTOGRAPH OF WETLANDS TO BE IMPACTED BY PROJECT. (0 IF DELINEATION WAS PERFORMED BY A CONSULTANT, INCLUDE ALL DATA SHEETS RELEVANT TO THE PLACEMENT OF THE DELINEATION LINE. (d) ATTACH A COPY OF THE STORMWATER MANAGEMENT PLAN IF REQUIRED. (c) WHAT IS LAND USE OF SURROUNDING PROPERTY:' RcsWentia /m mmomial (I) IF APPLICABLE, WHAT IS PROPOSED METHOD OF SEWAGE DISPOSAL? Sanitwy sewer system. SIGNED AND DATED' AGENT AUTHORIZATION LETTER, IF APPLICABLE. NOTE: WETLANDS OR WATERS OF TIM US MAY NOT BE IMPACTED PRIOR TO: 1. ISSUANCE OF A SECTION 404 CORPS OF ENGINEERS PERMIT. 2. EITHER THE ISSUANCE OR WAIVER OF A 401 DIVISION OF WATER QUALITY CERTIFICATION, AND 3. (IN THE TWENTY COASTAL COUNTIES ONLY), A LETTER FROM THE NORTH LIMA DIVISION OF COASTAL MANAGEMENT STATING THE PROPOSED t Ty IS CONSISTENT WITH THE NORTH CAROLINA COASTAL MANAGEMENT oa SIGNATURE DATE (AGENT'S SIGNATURE VALID ONLY IF AUTHORIZATION LETTER FROM THE OWNER IS PROVIDED). Feb-28-00 05:31P State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director L19WAA / • NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES February 22, 2000 f4irsyth County DWQ Project 4 000253 APPROVAL of 401 Water Quality Certification with Additional Conditions Scutt Boldt, KDA Financial 350 Franklin Road Marietta, GA 30067 P_02 Dear Mr. Boldt: You have our approval, in accordance with the attached conditions and those listed below, to construct a pond and a road crossing which will impact a total of 452 feet of stream channel for the purpose of cummcrcial construction in Forsyth County, a, you described in your application received by the Division of Water Quality on February 11, 2000. After reviewing your application, we have decided that this action is covered by General Water Quality Certification Numbers 3103 and 3108. This certification allows you to use Nationwide Permit Numbers 14 and 26 when the Corps of Engineers issues it. In addition, you should get any other federal, state or local permits before you go ahead with your project including (but not limited to) Sediment and Erosion Control, Coastal Stormwater, Non-Discharge and Water Supply Watershed regulations. This approval will expire when the accompanying 404 or CAMA permit expires unless otherwise specified in the General Certification. This approval is only valid for the purpose and design that you described in your application. If you change your project, you must notify us and you may be required to send us a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter and is thereby responsible for complying with all conditions. If total wetland fills for this project (now or in the future) exceed one acre, compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to be valid you must follow the conditions below and those listed in the attached certification. I. An additional condition is that a final, written stormwater management plan shall be approved by this Office before the impacts specified in this Certification occur. The stormwater management plan must include plans and specifications for stormwater management facilities designed to remove 85% TSS according to the most recent version of the NC DENR Srormwater Best Management Practices Manual. Also, before any permanent building is occupied at the subject site, the facilities, as approved by this Office, shall be constructed and operational, and the stormwater management plan, as approved by this Office, shall be implemented. ll' you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter I50B of the North Carolina General Statutes to the Office of Administrative Hearings, P.O. Box 27147, Raleigh, N.C. 27 6 1 1-7447. This certification and its conditions arc final and binding unless you ask for a hearing. This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone John Dorney at 919-733-9646. Attachment cc: Corps of Engineers Raleigh Field Office Winston-Salem DWQ Regional Office Denis Poulos, Engineering Consulting Services, 5-C Dundas Circle, Greensboro. NC 27407 File Copy Central Files 000253 L L; ice.;;,' ? r ?•'•r°• • :,,: J -.?IJ? ?' . .? ? 80 i l'? ?•. ? r i1 ll: ` n I 81c _ ? 4 \1 L,. e I Pln . • 1 ?!- ' r-?;?/ ' i .fit?Gr' ?_'??'` ?i 1 I (?? ` i ^ ? / 1 ?::% ?• ? `?. D??? C ?`••? "`ice C/? i (? / i r e SOURCE: C's FIGURE 1 USGS TOPOGRAPHIC MAP, LTD SITE LOCATION MAP WINSTON-SALEM WEST, NC PROPOSED COMMERCIAL QUADRANGLE, DATED 1950 AND BUILDING REVISED 1994 ENGINEERING WINSTON-SALEM, NC SCALE: I"= 2,000• CONSULTING ECS PROJECT G-3434F SERVICES,LTD DATA FORNI ROUTINE WETLAND DETERMINATION 1987 COE Wetlands Delineation Manual) Project/Site: Approximate 12 Acre Tract - I-40 @ Stratford Road Project No: Date: October 4, 1999 Applicant/Owner: KDA Financial County: Forsyth Investigators: Denise M. Poulos/ ECS, LTD. G-3434 State: North Carolina Plot ID: Data Point I Do Normal Circumstances exist on the site? Yes No Community ID: Is the site significantly disturbed (Atypical Situation:):' Yes vo Transect ID: Is the area a potential Problem Area.? Yes No Field Location: Near SB-20 (If needed, explain on the reverse side) HYDROLOGY Recorded Data (Describe in Remarks): Wetland Hydrology Indicators Stream, Lake or Tide Gauge Primary Indicators Aerial Photographs Inundated Other X Saturated in Upper 12 Inches Water blarks X No Recorded Data Drift Lines X Sediment Deposits Field Observations Drainage Patterns in Wetlands Secondary Indicators Depth of Surface Water: 0" Oxidized Root Channels in Upper 12 Inches Water-Stained Leaves Depth to Free Water in Pit: >12" Local Soil Survey Data FAC-Neutral Test Depth to Saturated Soil: 6" Other (Explain in Remarks) Remarks: Wetland hydrology indicators were observed. Page 1 of 2 Wetform) Jig lt6 flap Unit Name (Series and Phase): Pacolet fine sandy loam Mapped Hydric Inclusion? Yes Yo Map Symbol: PaC Drainage Class: Well Drained N Field Observations Confirm Mapped Type: Yes o Taxonomy (Subgroup): Typic hapludults Profile Description Depth Matrix Color Mottle Color ivlottle (inches) Horizon OvItinsell Moist) (Munsell Moist) Abundance/Contrast Texture. Concretions, Structure, etc. 0-12 10YR 6/6 Loamy sand I I L Hydric Soil Indicators: Histosol Concretions High Organic Content in Surface Layer in Sandy Soils Histic Epipedon Sulfidic Odor Organic Streaking in Sandy Soils Aquic Moisture Regime Listed on Local Hvdric Soils List Reducing Conditions Listed on National Hydric Soils List Gle ed or Low Chroma Colors Other (Explain in Remarks) Remarks: Hydric soil indicators were not observed. i WETLAND DETERiN[INATION Hydrophytic Vegetation Present? Yes No Is the Sampling Point within the Wetland? Yes No Wetland Hydrology Present? Yes No Hydric Soils Present? Yes No Remarks: The wetland criteria were not present. The sampling point is not located within a wetland. Page 2 of 2 (Wetform) r;. y r. e ENGINEERING CONSULTING SERVICES, LTD. Geotechnical • Construction Materials • Environmental ;ohn Dorney t. , rlt?t Carolina Department of Environment and Natural Resources Jet -4621 Mai( Service Center Subject: Revised Pre-Construction Notification Application Proposed Commercial Building Winston-Salem, Forsyth County, North Carolina ECS Project G-3434F ion of Water Quality and/401 Unit Raleigh, North Carolina 27699-1621 Dear Mr. Dorney: September 5, 2000 Please find seven copies of the revised Pre-Construction Notification Application for the above referenced site. Both Mr. Todd St. John and Ms. Jennifer Frye are familiar with the site. The site is approximately 10 acres in area and is located on Westbrook Plaza Drive in Winston-Salem (Figure 1). The site is to be developed with a three story commercial building and associated parking areas. A 401 Water Quality Certification was issued for the project on February 22, 2000 (DWQ Project # 000253). A copy of this certification is included with this package. Tributaries of Little Creek cross the site. Approximately 294 linear feet of intermittent stream channel will be impacted by the construction of a stormwater pond. The stream will be diverted around the pond in order to avoid treating off-site stormwater in the pond. The intermittent stream channel will be graded during construction of the pond. The stream currently enters the site through a 30" RCP. The stream was designated as intermittent by Ms. Jennifer Frye of the North Carolina Division of Water Quality in October 1999. Approximately 147.5 linear feet of perennial stream channel will be impacted by the construction of a roadway/dam. In order to minimize the impact to the perennial portion of the stream, the roadway/dam have been combined. The proposed development is illustrated on the attached Grading and Erosion Control Plan prepared by Stimmel Associates, P.A. We are requesting a 401 Water Quality Certification for the impact to 294 linear feet of intermittent stream channel and 147.5 linear feet of perennial stream channel. As the impact to the perennial portion of the stream channel is less than 150 linear feet, we are not including a mitigation plan with this request. A stormwater management plan has been designed to remove 85 % total suspended solids. The intermittent stream on the site is very low quality. It is our opinion, that the stormwater pond will be 5-C Dundas Circle, Greensboro, NC 27407 • (336) 856-7150 • Fax (336) 856-7160 Offices: Aberdeen, MD • Atlanta, GA • Austin, TX • Baltimore, MD • Chantilly, VA • Charlotte, NC • Chicago, IL • Frederick, MD • Fredericksburg, VA • Greensboro, NC • Greenville, SC • Norfolk, VA • Raleigh, NC • Richmond, VA • Roanoke, VA • Williamsburg, VA • Wilmington, NC Section 401 Permitting Proposed Commercial Building ECS Project G-3434F more effective in preserving water quality. The stormwater pond design specifications have been forwarded to Mr. Todd St. John for his review. Please feel free to contact me at (336) 856-7150 if you have any questions concerning this request or if additional information is required. Thank you in advance for your timely consideration of this matter. Sincerely, ENGINEERING CONSULTING SERVICES, LTD. Denise M. Poulos, LSS Principal Scientist Attachment: Pre-Construction Notification Application $475.00 Application Fee 2 DWQ ID: _ CORPS ACTION ID: NATIONWIDE PERMIT REQUESTED (PROVIDE NATIONWIDE PERMIT #) 14,26 PRE-CONSTRUCTION NOTIFICATION APPLICATION FOR NATIONWIDE PERMITS THAT REQUIRE: 1. NOTIFICATION TO THE CORPS OF ENGINEERS 2. APPLICATION FOR SECTION 401 CERTIFICATION 3. COORDINATION WITH THE NC DIVISION OF COASTAL MANAGEMENT SEND THE ORIGINAL AND (1) COPY OF THIS COMPLETED FORM TO THE APPROPRIATE FIELD OFFICE OF THE CORPS OF ENGINEERS (SEE AGENCY ADDRESSES SHEET). SEVEN (7) COPIES MUST BE SENT TO THE NC DIVISION OF WATER QUALITY ATTN• JOHN DORNEY, 4401 REEDY CREEK ROAD, RALEIGH, NC 27607. PLEASE PRINT OR TYPE. 1. OWNER'S NAME: Mr Scott Boldt, KDA Financial 2. MAILING ADDRESS: 350 Franklin Road SUBDIVISION NAME CITY: Marietta STATE: Georeia ZIP CODE: 30067 PROJECT LOCATION ADDRESS, INCLUDING SUBDIVISION NAME (IF DIFFERENT FROM MAILING ADDRESS ABOVE): The project is located on Westbrook Plaza Drive in Winston-Salem. 3. TELEPHONE NUMBER: (HOME) _ (WORK) (770) 421-1532 4. IF APPLICABLE: AGENT'S NAME OR RESPONSIBLE CORPORATE OFFICIAL, ADDRESS, PHONE NUMBER: Denise M Poulos Engineering Consulting Services Ltd 5-C Dundas Circle Greensboro NC 27407, (336) 856-7150 5. LOCATION OF WORK (PROVIDE A MAP, PREFERABLY A COPY OF USGS TOPOGRAPHIC MAP OR AERIAL PHOTOGRAPHY WITH SCALE): COUNTY: Forsyth - NEAREST TOWN: Winston-Salem SPECIFIC LOCATION (INCLUDE ROAD NUMBERS, LANDMARKS, ETC.) The site is located on Westbrook Plaza Drive in Winston-Salem. 6. IMPACTED OR NEAREST STREAM/RIVER: Little Creek/Muddy Creek RIVER BASIN: Yadkin/PeeDee 7. (a) IS PROJECT LOCATED NEAR WATER CLASSIFIED AS TROUT, TIDAL SALTWATER, (SA), HIGH QUALITY WATERS (HQW), OUTSTANDING RESOURCE WATERS (ORW), WATER SUPPLY (WS-I OR WS-II)? YES ? NO X IF YES, EXPLAIN: (b) IS THE PROJECT LOCATED WITHIN A NORTH CAROLINA DIVISION OF COASTAL MANAGEMENT AREA OF ENVIRONMENTAL CONCERN (AEC)? YES ? NO ? (c) IF THE PROJECT IS LOCATED WITHIN A COASTAL COUNTY (SEE PAGE 7 FOR LIST OF COASTAL COUNTIES), WHAT IS THE LAND USE PLAN (LUP) DESIGNATION? 8. (a) HAVE ANY SECTION 404 PERMITS BEEN PREVIOUSLY REQUESTED FOR USE ON THIS PROJECT? YES X NO IF YES, PROVIDE ACTION I.D. NUMBER OF PREVIOUS PERMIT AND ANY ADDITIONAL INFORMATION (INCLUDE PHOTOCOPY OF 401 CERTIFICATION): 200020694 (b) ARE ADDITIONAL PERMIT REQUESTS EXPECTED FOR THIS PROPERTY IN THE FUTURE? YES ? NO X IF YES, DESCRIBE ANTICIPATED WORK: (a) ESTIMATED TOTAL NUMBERS OF ACRES IN TRACT OF LAND: 10 Acres (b) ESTIMATED TOTAL NUMBER OF ACRES OF WETLANDS LOCATED ON PROJECT SITE: A tributary of Little Creek crosses the site There are no wetlands present on the site. 10. (a) NUMBER OF ACRES OF WETLANDS IMPACTED BY THE PROPOSED PROJECT BY: FILLING: _ EXCAVATION: FLOODING: OTHER: DRAINAGE : TOTAL ACRES TO BE IMPACTED: NA (b) (1) STREAM CHANNEL TO BE IMPACTED BY THE PROPOSED PROJECT (IF RELOCATED, PROVIDE DISTANCE BOTH BEFORE AND AFTER RELOCATION: LENGTH BEFORE: _ FT AFTER: _ FT WIDTH BEFORE (based on normal high water contours): _ FT AVERAGE DEPTH BEFORE: _ FT AFTER: _ FT (b) (2) STREAM CHANNEL IMPACTS WILL RESULT FROM: (CHECK ALL THAT APPLY) OPEN CHANNEL RELOCATION: _ PLACEMENT OF PIPE IN CHANNEL: X CHANNEL EXCAVATION: - CONSTRUCTION OF A DAM/FLOODING: X OTHER: Diversion 11. IF CONSTRUCTION OF A POND IS PROPOSED, WHAT IS THE SIZE OF THE WATERSHED DRAINING TO THE POND? 30.3 acres WHAT IS THE EXPECTED POND SURFACE AREA? 0.5 acres 12. DESCRIPTION OF PROPOSED WORK INCLUDING DISCUSSION OF TYPE OF MECHANICAL EQUIPMENT TO BE USED? (ATTACH PLANS; 81/2 BY 1 1 DRAWINGS ONLY) The site is to be developed with a three storyoffiice building and parkins lots The building and parking lots will be constructed in high ground Only a stormwater pond and a roadway will impact the stream located on the site Truck loaders excavators backhoes bulldozers etc will be used to develop the site. 13. PURPOSE OF PROPOSED WORK: The site is to be developed with a three story office building and a stormwater pond. 14. STATE REASONS WHY IT IS BELIEVED THAT THIS ACTIVITY MUST BE CARRIED OUT IN WETLANDS (INCLUDE ANY MEASURES TAKEN TO MINIMIZE WETLAND IMPACTS) Due to the topography of the site a stormwater pond will be constructed near the eastern boundary. This will impact approximately 294 If of intermittent stream channel due to diversion and fill. To minimize impacts the dam/access road have been combined The dam/road will impact approximately 147.5 If of perennial stream channel. 15. YOU ARE REQUIRED TO CONTACT THE US FISH AND WILDLIFE SERVICE AND/OR NATIONAL MARINE FISHERIES SERVICE REGARDING THE PRESENCE OF ANY FEDERALLY LISTED OR PROPOSED FOR LISTING ENDANGERED OR THREATENED SPECIES OR CRITICAL HABITAT IN THE PERMIT AREA THAT MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED: 16. YOU ARE REQUIRED TO CONTACT THE STATE HISTORIC PRESERVATION OFFICER (SHPO) REGARDING THE PRESENCE OF HISTORIC PROPERTIES IN THE PERMIT AREA WHICH MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED _. Feb -07-00 04p:a35P P.Ol rcnrtNGiMEERING ONSULTING SRVS LTD +3368567160 T-153 P-002 O02 F-346 17. DOES THE PROJECT INVOLVE AN EXPENDITURE OF PUBLIC FUNDS OR THE USE OF PUBLIC (STATE) LAND? YES ? NO X (IF NO, GO TO 16) (a) IF YES, DOES TIM PROJECT REQUIRE PREPARATION OF AN ENVIRONMENTAL DOCUMENT PURSUANT TO THE REQUIREMENTS OF THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT? YES ? NO ? (b) IF YES, HAS THE DOCUMENT BEEN REVIEWED THROUGH THE NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CLEARINGHOUSE YES ? NO ? IF ANSWER 17b IS YES, T}IEN SUBMIT APPROPRIATE DOCUMENTATION FROM THE STATE CLEARINGHOUSE WITH THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT, QUESTIONS REGARDING TIE STATE CLEARINGHOUSE REVIEW PROCESS SHOULD BE DIRECTED TO MS. CHRYS BAGGETT, DIRECTOR STATE CLEARINGHOUS1w NORTH CAROLINA DEPARTMENT OF ADMINISTRATION, 116 WEST JONES STREET, RALEIGH, NORTH CAROLINA 27603-8003. TELEPHONE (919) 733-6369. 1 B THE FOLLOWING ITEMS SHOULD BE INCLUDED WITH THIS APPLICATION IF PROPOSED ACTIVITY INVOLVES IBM DISCHARGE OF EXCAVATED OF FILL MATERIAL INTO WETLANDS: (a) WETLAND DELINEATION MAP SHOWING ALL WETLANDS, STREAMS, LAKES, AND PONDS ON THE PROPERTY (FOR NATIONWIDE PERMIT NUMBERS 14, 13, 21, 26, 29, AND 38). ALL STREAM (INTERMITTENT AND PERMANENT) ON THE PROPERTY MUST BE SHOWN ON THE MAP. MAP SCALES SHOULD BE 1 INCH EQUALS SO FEET OF 1 INCH EQUALS 100 FEET OF THEIR EQUIVALENT. (b) IF AVAILABLE, REPRESENTATIVE PHOTOGRAPH OF WETLANDS TO BE IMPACTED BY PROJECT. (c) IF DELINEATION WAS PERFORMED BY A CONSULTANT, INCLUDE ALL DATA SHEETS RELEVANT TO THE PLACEMENT OF THE DELINEATION LINE. (d) ATTACH A COPY OF THE STORMWATER MANAGEMENT PLAN IF REQUIRED. (c) WHAT IS LAND USE OF SURROUNDING PROPERTY? RcsWcadaUc=rnorcial M IF APPLICABLE, WHAT IS PROPOSED METHOD OF SEWAGE DISPOSAL? Sani sewer system. SIGNED AND DATMAGENT AUTHORIZATION LETTER, IF APPLICABLE. NOTE: WETLANDS OR WATERS Of THE US MAY NOT BE IMPACTED PRIOR TO: 1. ISSUANCE OF A SECTION 404 CORPS OF ENGINEERS PERMIT, 2. EITHER THE ISSUANCE OR WAIVER OF A 401 DIVISION OF WATER QUALITY CERTIFICATION, AND 3. (IN THE TWENTY COASTAL COUNTIES ONLY), A LETTER FROM THE NORTH LIMA DIVISION OF COASTAL MANAGEMENT STATING THE PROPOSED t ITY IS CONSISTENT WTIH THE NORTH CAROLINA COASTAL MANAGEMENT all 100 SIGNA (AGENT'S SIGNATURE VALID ONLY IF AUTHORIZATION LETTER FROM THE OWNER IS PROVIDED). Feb-28-00 05:31P State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director ffl?wx'A 1 • A NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES February 22, 2000 Ftlrsvth County D) VQ Project ># 000253 APPROVAL of 401 Water Quality Certification with Additional Conditions Scott Buldt, KDA Financial 330 Franklin Road Marietta. GA 30067 P.02 Dear Mr. Buldt: You have our approval, in accordance with the attached conditions and those listed below, to construct a pond and a road crossing, which will impact a total of 452 feet of stream channel for the purpose of commercial construction in Forsyth County, as you described in your application received by the Division of Water Quality on February 11, 2000. After reviewing your application, we have decided that this action is covered by General Water Quality Certification Numbers 3103 and 3108. This certification allows you to use Nationwide Permit Numbers 14 and 26 when the Corps of Engineers issues it. In addition, you should get any other federal, state or local permits before you gu ahead with your project including (but not limited to) Sediment and Erosion Control. Coastal Stormwater, Non-Discharge and Water Supply Water shed regulations. This approval will expire when the accompanying 404 or CAMA permit expires unless otherwise specified in the General Certification. This approval is only valid for the purpose and design that you described in your application. If you change your project, you must notify us and you may be required to send us a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter and is thereby responsible for complying with all conditions. [['total wetland fills for this pmject (now or in the future) exceed one acre, compensatory mitigation may be n:quired as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to be valid you must follow the conditions below and those listed in the attached certification. 1. An additional condition is that a final, written stormwater management plan shall be approved by this Office before the impacts specified in this Certification occur. The stormwater management plan must include plans and specifications for stormwater management facilities designed to remove 85%n TSS according to the most recent version of the NC DENR Starmwater Best Management Practices Manual. Also, before any permanent building is occupied at the subject site, the facilities, as approved by this Office, shall be constructed and operational, and the stormwater management plan, as approved by this Oft ice, shall be implemented. Il' you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter 1508 of the North Carolina General Statutes to the Office of Administrative Hearings, P.O. Box 27447, Raleigh, N.C. 276 1 1-7447. This certification and its conditions arc final and binding unless you ask for a hearing. This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone John Dorney at 919-733-9646. Attachment cc: Corps of Engineers Raleigh Field Office Winston-Salem DWQ Regional Office Denis Poulos, Engineering Consulting services, 5-C Dundas Circle, Greensboro, NC 27407 File Copy Central Files 000253 ? u •? ~,?-.r ` (' ..rte .? • - ? ? \ \ ? ,r/Il J?/?i?,".?I ??t;, ( `-'.?? \? j ' .,?. s0 i ??'• 1 ???.•. ?•, ? ?'¦ii? is y v ???:,J, n. ? 'Irk ,/?• a r;-,.; -x, is j c'- c `? ?'." % ? ???? 1 .Xrm = T_.? 111 .??//? l?i..,I I ?..??F ? ? • y ,.rQ _ --• ????? ?? ???'.?i/"`"-/?'..r`' '?? ? ? ? •s???. aye' \_ !. ? d ° ?'?, • ..rr? IV. ¦ SOURCE: FIGURE 1 USGS TOPOGRAPHIC MAP, LTD SITE LOCATION MAP WINSTON-SALEM WEST, NC PROPOSED COMMERCIAL QUADRANGLE, DATED 1950 AND BUILDING REVISED 1994 ENGINEERING WINSTON-SALEM, NC SCALE: I"= 2,000, CONSULTING ECS PROJECT G-3434F SERVICES,LTD DATA FORM ROUTINE WETLAND DETERMINATION 1987 COE Wetlands Delineation Manual) Project/Site: Approximate 12 Acre Tract - I-30 @ Stratford Road Project No: Date: October 4, 1999 Applicant/Owner: KDA Financial County: Forsyth Investigators: Denise M. Poulos/ ECS, LTD. G-3433 State: North Carolina Plot ID: Data Point I Do Normal Circumstances exist on the site? Yes No Community ID: Is the site significantly disturbed (Atypical Situation:)? Yes No Transect ID: Is the area a potential Problem Area? Yes No Field Location: Near SB-20 (If needed, explain on the reverse side) V LUL I A 11UP4 Dominant Plant Species (Latin/Common) Stratum Indicator Plant Species (Latin/Common) Stratum Indicator s s ti I p. en mpa Touch-me-not Herb FACW i on radicans d d i T r en co ox Poison ivy onica i Herb FAC cera jap Lon Japanese honeysuckle lia dif t V Vine FAC- un o itis ro Muscadine grape Vine FAC Percent of Dominant Species that are OBL, FACW or FAC: FAC Neutral: (excluding FAC-) 100% Numeric Index: E;emarks: The dominant vegetation is hydro h ic. HYDROLOGY Recorded Data (Describe in Remarks): Stream, Lake or Tide Gauge Aerial Photographs Other X No Recorded Data Field Observations Depth of Surface Water: 0" Depth to Free Water in Pit: >12" Depth to Saturated Soil: 6" Remarks: Wetland Hydrology Indicators Primary Indicators Inundated X Saturated in Upper 12 Inches Water Marks Drift Lines X Sediment Deposits Drainage Patterns in Wetlands Secondary Indicators Oxidized Root Channels in Upper 12 Inches Water-Stained Leaves Local Soil Survey Data FAC-Neutral Test Other (Explain in Remarks) 11 Wetland hydrology indicators were ooserveu. Page 1 of 2 (Wetform) Jli LLJ Map Unit Name (Series and Phase): Pacolet fine sandy loam Map Symbol: PaC Drainage Class: Well Drained Mapped Hydric Inclusion? Yes No Taxonomy (Subgroup): Typic hapludults Field Observations Confirm Mapped Type: Yes No Profile Descri tion Depth Matrix Color Mottle Color Mottle (inches) Horizon Munsell Moist) (Munsell Moist) Abundance/Contrast Texture, Concretions, Structure, etc. 0_12 10YR 6/6 Loamy sand I i Hydric Soil Indicators: Histosol Concretions Histic Epipedon High Organic Content in Surface Layer in Sandy Soils Sulfidic Odor Organic Streaking in Sandy Soils Aquic Moisture Regime Listed on Local Hydric Soils List Reducing Conditions Listed on National Hydric Soils List Gleved or Low Chroma Colors Other (Explain in Remarks) Remarks: Hydric soil indicators were not observed. I I VVC,1Lr?`1L LLtr.ntrui?:-% liviI Is the Sampling Point within the Wetland? Yes No Hydrophytic Vegetation Present? Yes No Wetland Hydrology Present? Yes No Hydric Soils Present? Yes No Remarks: The wetland criteria were not present. The sampling point is not located within a wetland. Page 2 of 2 Wetform) ENGINEERING CONSULTING SERVICES, LTD. Geotechnical - Construction Materials - Environmental W_ I c^Y ' N6','? lohn Dorney ?f To>aCarolina Department of Environment and Natural Resources ?=:6ivision of Water Quality Wetland/401 Unit 1621 Mail Service Center Raleigh, North Carolina 27699-1621 Subject: Revised Pre-Construction Notification Application Proposed Commercial Building Winston-Salem, Forsyth County, North Carolina ECS Project G-3434F Dear Mr. Dorney: September 5, 2000 Please find seven copies of the revised Pre-Construction Notification Application for the above referenced site. Both Mr. Todd St. John and Ms. Jennifer Frye are familiar with the site. The site is approximately 10 acres in area and is located on Westbrook Plaza Drive in Winston-Salem (Figure 1). The site is to be developed with a three story commercial building and associated parking areas. A 401 Water Quality Certification was issued for the project on February 22, 2000 (DWQ Project # 000253). A copy of this certification is included with this package. Tributaries of Little Creek cross the site. Approximately 294 linear feet of intermittent stream channel will be impacted by the construction of a stormwater pond. The stream will be diverted around the pond in order to avoid treating off-site stormwater in the pond. The intermittent stream channel will be graded during construction of the pond. The stream currently enters the site through a 30" RCP. The stream was designated as intermittent by Ms. Jennifer Frye of the North Carolina Division of Water Quality in October 1999. Approximately 147.5 linear feet of perennial stream channel will be impacted by the construction of a roadway/dam. In order to minimize the impact to the perennial portion of the stream, the roadway/dam have been combined. The proposed development is illustrated on the attached Grading and Erosion Control Plan prepared by Stimmel Associates, P.A. We are requesting a 401 Water Quality Certification for the impact to 294 linear feet of intermittent stream channel and 147.5 linear feet of perennial stream channel. As the impact to the perennial portion of the stream channel is less than 150 linear feet, we are not including a mitigation plan with this request. A stormwater management plan has been designed to remove 85 % total suspended solids. The intermittent stream on the site is very low quality. It is our opinion, that the stormwater pond will be 5-C Dundas Circle, Greensboro, NC 27407 - (336) 856-7150 - Fax (336) 856-7160 Offices: Aberdeen, MD - Atlanta, GA - Austin, TX - Baltimore, MD - Chantilly, VA - Charlotte, NC - Chicago, IL - Frederick, MD - Fredericksburg, VA - Greensboro, NC - Greenville, SC - Norfolk, VA - Raleigh, NC - Richmond, VA - Roanoke, VA - Williamsburg, VA - Wilmington, NC Section 401 Permitting Proposed Commercial Building ECS Project G-3434F more effective in preserving water quality. The stormwater pond design specifications have been forwarded to Mr. Todd St. John for his review. Please feel free to contact me at (336) 856-7150 if you have any questions concerning this request or if additional information is required. Thank you in advance for your timely consideration of this matter. Sincerely, ENGINEERING CONSULTING SERVICES, LTD. enise M. Poulos, LSS Principal Scientist Attachment: Pre-Construction Notification Application $475.00 Application Fee 2 DWQ ID: _ CORPS ACTION ID: NATIONWIDE PERMIT REQUESTED (PROVIDE NATIONWIDE PERMIT #) 14,26 PRE-CONSTRUCTION NOTIFICATION APPLICATION FOR NATIONWIDE PERMITS THAT REQUIRE: 1. NOTIFICATION TO THE CORPS OF ENGINEERS 2. APPLICATION FOR SECTION 401 CERTIFICATION 3. COORDINATION WITH THE NC DIVISION OF COASTAL MANAGEMENT SEND THE ORIGINAL AND (1) COPY OF THIS COMPLETED FORM TO THE APPROPRIATE FIELD OFFICE OF THE CORPS OF ENGINEERS (SEE AGENCY ADDRESSES SHEET). SEVEN (7) COPIES MUST BE SENT TO THE NC DIVISION OF WATER QUALITY ATTN• JOHN DORNEY, 4401 REEDY CREEK ROAD, RALEIGH, NC 27607. PLEASE PRINT OR TYPE. 1. OWNER'S NAME: Mr. Scott Boldt. KDA Financial 2. MAILING ADDRESS: 350 Franklin Road SUBDIVISION NAME CITY: Marietta STATE: Georgia ZIP CODE: 30067 PROJECT LOCATION ADDRESS, INCLUDING SUBDIVISION NAME (IF DIFFERENT FROM MAILING ADDRESS ABOVE): The proiect is located on Westbrook Plaza Drive in Winston-Salem. 3. TELEPHONE NUMBER: (HOME) _ (WORK) (770) 421-1532 4. IF APPLICABLE: AGENT'S NAME OR RESPONSIBLE CORPORATE OFFICIAL, ADDRESS, PHONE NUMBER: Denise M Poulos Engineering Consulting Services Ltd 5-C Dundas Circle Greensboro NC 27407, (336) 856-7150 5. LOCATION OF WORK (PROVIDE A MAP, PREFERABLY A COPY OF USGS TOPOGRAPHIC MAP OR AERIAL PHOTOGRAPHY WITH SCALE): COUNTY: Forsyth - NEAREST TOWN: Winston-Salem SPECIFIC LOCATION (INCLUDE ROAD NUMBERS, LANDMARKS, ETC.) The site is located on Westbrook Plaza Drive in Winston-Salem. 6. IMPACTED OR NEAREST STREAM/RIVER: Little Creek/Muddy Creek RIVER BASIN: Yadkin/PeeDee 7. (a) IS PROJECT LOCATED NEAR WATER CLASSIFIED AS TROUT, TIDAL SALTWATER, (SA), HIGH QUALITY WATERS (HQW), OUTSTANDING RESOURCE WATERS (ORW), WATER SUPPLY (WS-I OR WS-II)? YES ? NO X IF YES, EXPLAIN: COASTAL (b) IS THE OAREA OF ENVIRONMENTAL CONCERN (AC)? YES [] NO Q MANAGEMENT (c) IF THE PROJECT IS LOCATED WITHIN A COASTAL COUNTY (SEE PAGE 7 FOR LIST OF COASTAL COUNTIES), WHAT IS THE LAND USE PLAN (LUP) DESIGNATION? 8. (a) HAVE ANY SECTION 404 PERMITS BEEN PREVIOUSLY REQUESTED FOR USE ON THIS PROJECT? YES X NO IF YES, PROVIDE ACTION I.D. NUMBER OF PREVIOUS PERMIT AND ANY ADDITIONAL INFORMATION (INCLUDE PHOTOCOPY OF 401 CERTIFICATION): 200020694 (b) ARE ADDITIONAL PERMIT REQUESTS EXPECTED FOR THIS PROPERTY IN THE FUTURE? YES ? NO X IF YES, DESCRIBE ANTICIPATED WORK: 9. (a) ESTIMATED TOTAL NUMBERS OF ACRES IN TRACT OF LAND: 10 Acres (b) ESTIMATED TOTAL NUMBER OF ACRES OF WETLANDS LOCATED ON PROJECT SITE: A tributary of Little Creek crosses the site. There are no wetlands present on the site. 10. (a) NUMBER OF ACRES OF WETLANDS IMPACTED BY THE PROPOSED PROJECT BY: FILLING: _ EXCAVATION: FLOODING: OTHER: DRAINAGE : TOTAL ACRES TO BE IMPACTED: NA (b) (1) STREAM CHANNEL TO BE IMPACTED BY THE PROPOSED PROJECT (IF RELOCATED, PROVIDE DISTANCE BOTH BEFORE AND AFTER RELOCATION: LENGTH BEFORE: _ FT AFTER: - FT WIDTH BEFORE (based on normal high water contours): _ FT AVERAGE DEPTH BEFORE: _ FT AFTER: - FT (b) (2) STREAM CHANNEL IMPACTS WILL RESULT FROM: (CHECK ALL THAT APPLY) OPEN CHANNEL RELOCATION: - PLACEMENT OF PIPE IN CHANNEL: X CHANNEL EXCAVATION: - CONSTRUCTION OF A DAM/FLOODING: X OTHER: Diversion 11. IF CONSTRUCTION OF A POND IS PROPOSED, WHAT IS THE SIZE OF THE WATERSHED DRAINING TO THE POND? 30.3 acres WHAT IS THE EXPECTED POND SURFACE AREA? 0.5 acres 12. DESCRIPTION OF PROPOSED WORK INCLUDING DISCUSSION OF TYPE OF MECHANICAL EQUIPMENT TO BE USED? (ATTACH PLANS; 81/2 BY 11 DRAWINGS ONLY) The site is to be developed with a three story office building and parkins lots The building and parkins; lots will be constructed in high ground Only a stormwater pond and a roadway will impact the stream located on the site Truck loaders excavators backhoes bulldozers etc will be used to develop the site. 13. PURPOSE OF PROPOSED WORK: The site is to be developed with a three story office building and a stormwaterpond. 14. STATE REASONS WHY IT IS BELIEVED THAT THIS ACTIVITY MUST BE CARRIED OUT IN WETLANDS (INCLUDE ANY MEASURES TAKEN TO MINIMIZE WETLAND IMPACTS) Due to the topography of the site a stormwater pond will be constructed near the eastern boundary. This will impact approximately 294 If of intermittent stream channel due to diversion and fill. To minimize impacts the dam/access road have been combined The dam/road will impact approximately 147.5 If of perennial stream channel. 15. YOU ARE REQUIRED TO CONTACT THE US FISH AND WILDLIFE SERVICE AND/OR NATIONAL MARINE FISHERIES SERVICE REGARDING THE PRESENCE OF ANY FEDERALLY LISTED OR PROPOSED FOR LISTING ENDANGERED OR THREATENED SPECIES OR CRITICAL HABITAT IN THE PERMIT AREA THAT MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED: 16. YOU ARE REQUIRED TO CONTACT THE STATE HISTORIC PRESERVATION OFFICER (SHPO) REGARDING THE PRESENCE OF HISTORIC PROPERTIES IN THE PERMIT AREA WHICH MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED _. Feb-07-00 04:35P P_01 r?c-ur-cuuu 11:40101 rr=-tnGlnEExlnG GGNSULTING SRVS LTD +3368567160 T-163 P.0021002 F-346 17. DOES THE PROJECT INVOLVE AN EJGaENDfTURE OF PUBLIC FUNDS OR THE USE OF PUBLIC (STATE) LAND? YES ? NO X (IF NO, GO TO 16) (a) IF YES, DOES THE PROJECT REQUIRE PREPARATION OF AN ENVIRONMENTAL DOCUMENT PURSUANT TO THE REQUIREMENTS OF THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT? YES ? NO ? (b) IF YES, HAS THE DOCUMENT BEEN REVIEWED THROUGH THE NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CLEARINGHOUSE YES ? NO ? IF ANSWER 17b IS YES, THEN SUBMIT APPROPRIATE DOCUMENTATION FROM THE STATE CLEARINGHOUSE WITH THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT, QUESTIONS REGARDING THE STATE CLEARINGHOUSE REVIEW PROCESS SHOULD BE DIRECTED TO MS. CHRYS BAGGETT, DIRECTOR STATE CLEARINGHOUSE, NORTH CAROLINA DEPARTMENT OF ADMINISTRATTON, 116 WEST JONES STREET, RALEIGH, NORTH CAROLINA 27603-8003, TELEPHONE (919) 733-6369. i 8 THE FOLLOWING ITEMS SHOULD BE INCLUDED WAIT THIS APPLICATION IF PROPOSED ACTIVITY INVOLVES THE DISCHARGE OF EXCAVATED OF FILL MATERIAL INTO WETLANDS: (a) WETLAND DELINEATION MAP SHOWING ALL WETLANDS, STREAMS, LAKES, AND PONDS ON THE PROPERTY (FOR NATIONWIDE PERMIT NUMBERS 14,13,21,26,29, AND 33). ALL STREAM (INTERMITTENT AND PERMANENT) ON THE PROPERTY MUST BE SHOWN ON THE MAP. MAP SCALES SHOULD BE 1 INCH EQUALS 50 FEET OF I INCH EQUALS 100 FEET OF THEIR EQUIVALENT. (b) 7 AVAILABLE, REPRESENTATIVE PHOTOGRAPH OF WETLANDS TO BE IMPACTED BY PROJECT. (c) IF DELINEATION WAS PERFORMED BY A CONSULTANT, INCLUDE ALL DATA SHEETS RELEVANT TO THE PLACEMENT OF THE DELINEATION LINE. (d) ATTACH A COPY OF THE STORMWATER MANAGEMENT PLAN IF REQUIRED. (c) WHAT IS LAND USE OF SURItOUNDING PROPERTY? RgsidentfaUcommomial (f) IF APPLICABLE, WHAT IS PROPOSED METHOD OF SEWAGE DISPOSAL? Sani sewer system. SIGNED AND DATED AGENT AUTHORIZATION LETTER, IF APPLICABLE. NOTE: WETLANDS OR WATERS OF THE US MAY NOT BE IMPACTED PRIOR TO: 1. ISSUANCE OF A SECTION 404 CORPS OF ENGINEERS PERMIT. 2. EITHER THE ISSUANCE OR WAIVER OF A 401 DIVISION OF WATER QUALITY CERTIFICATION, AND 3. (IN THE TWENTY COASTAL COUNTIES ONLY), A LETTER FROM THE NORTH LIMA DMSION OF COASTAL MANAGEMENT STATING THE PROPOSED F TY IS CONSISTENT WITH THE NORTH CAROLINA COASTAL MANAGEMENT all oa 0 GENTS SIGNATURE DATE (AGENT'S SIGNATURE VALID ONLY IF AUTHORIZATION LETTER FROM THE OWNER IS PROVIDED). Feb-28-00 05:31P State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director ILT?WJA / • , AM. NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES February 22, 2000 Forsyth County DWQ Project # 000253 APPROVAL of 401 Water Quality Certification with Additional Conditions Scott Boldt, KDA Financial 350 Franklin Road Marietta, GA 30067 P.02 Dear Mr. Buidt: You have our approval, in accordance with the attached conditions and those listed below, to construct a pond and a road crossing which will impact a total of 452 feet of stream channel for the purpose of commercial construction in Forsyth County, as you described in your application received by the Division of Water Quality on February 11, 2000. After reviewing your application, we have decided that this action is covered by General Water Quality Certification Numbers 3103 and 3108. This certification allows you to use Nationwide Permit Numbers 14 and 26 when the Corps of Engineers issues it. In addition, you should get any other federal, state or local permits before you go ahead with your project including (but not limited to) Sediment and Erosion Control, Coastal Stormwater, Non-Discharge and Water Supply Water shed regulations. This approval will expire when the accompanying 404 or CAMA permit expires unless otherwise specified in the General Certification. This approval is only valid for the purpose and design that you described in your application. If you change your project, you must notify us and you may be required to send us a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter and is thereby responsible for complying with all conditions. if total wetland rills for this project (now or in the future) exceed one acre, compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to be valid you must follow the conditions below and those listed in the attached certification. I. An additional condition is that a final, written stormwatermanagement plan shall be approved by this Office before the impacts specified in this Certification occur. The stormwater management plan must include plans and specifications for stormwater management facilities designed to remove 85% TSS according to the most recent version of the NC DENR Stormwater Best Management Practices Manual. Also, before any permanent building is occupied at the subject site, the facilities, as approved by this Office, shall be constructed and operational, and the stormwater management plan, as approved by this Office, shall be implemented. 11' you do not accept any of the conditions of this certification, you may ask for an adjudicatory he:uino. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter 1506 of the North Carolina General Statutes to the Office of Administrative Hearings, P,O. Box 27447, Raleigh, N.C. 276 1 1-7447. This certification and its conditions arc final and binding unless you ask for a hearing. This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone John Dorney at 919-733-9646. Attachment cc: Corps of Engineers Raleigh Field Office Winston-Salem DWQ Regional Office Denis Poulos, Engineering Consulting Services, 5-C Dundas Circle, Greensboro. NC 27407 File Copy Central Files 000253 ? i e -•`v ?..3 fl, -I ?; •?`•` III /r " r 1.4 J/rr?U, J n. !l. `?? „G, ° ?.a,? , ,.x , . I . 'I ,r. t --?'• ?.j ??// ?r? G _ 1TE j X/ Irk\? ? ?? -?;f ;; ? - ?r? `, ?J r/ ? • ,,ter-• \•??^??r? ?il? \,? 1. uQ5'? _r ?? _- F? ( i-:U _r J,, ! ??l ??•_ I arm- /; r ? a ? ^•? ? , i i . ISL.`. ; ??'? t?y? ??.1 \i? ?~ • ? • \ti ? /? ,/ ? ? ? : \ 1 ? l?i"-/++` ^ 1. ,•I i ?? ? - •:?\ `? i•' ?i ?`" ? ? ?? ?`? a ?• ?0 /? p\? 11 ?,?,. ? `L? ?? / '?':. \ /,'iQ pel 1 .7 SOURCE: FIGURE 1 USGS TOPOGRAPHIC MAP, LTD SITE LOCATION MAP WINSTON-SALEM WEST, NC PROPOSED COMMERCIAL QUADRANGLE, DATED 1950 AND BUILDING REVISED 1994 ENGINEERING WINSTON-SALEM, NC SCALE: I"= 2,000' CONSULTING ECS PROJECT G-3434F SERVICES,LTD DATA FORM ROUTINE 1NVETLAIND DETERMINATION (1987 COE Wetlands Delineation Manual) Project/Site: Approximate 12 Acre Tract - I-40 @ Stratford Road Project Yo: Date: October 4, 1999 Applicant/Owner: KDA Financial i County: Forsyth Investigators: Denise M. Poulos/ ECS, LTD. G-3434 State: North Carolina Plot ID: Data Point I Do Normal Circumstances exist on the site? Yes No Community ID: Is the site significantly disturbed (Atypical Situation:)? Yes Yo Transect ID: Is the area a potential Problem Area? • Yes No Field Location: Year SB-20 (If needed, explain on the reverse side) r. T . TT A IT V r ur.1H 11V1I Dominant Plant Species (Latin/Common) Stratum Indicator Plant Species (Latin/Common) Stratum Indicator Impatiens sp. Touch-me-not Herb FACW Toxicodendron radicans Poison ivy Herb FAC Lonicera japonica Japanese honeysuckle Vine FAC- Vitis rotundifolia Muscadine grape Vine FAC Percent of Dominant Species that are OBL, FACW or FAC: (excluding FAC-) 100% FAC Neutral: Numeric Index: Remarks: The dominant vegetation is hydro hytic. HYDKULUUY Recorded Data (Describe in Remarks): Wetland Hydrology Indicators Stream, Lake or Tide Gauge Primary Indicators Aerial Photographs Inundated Other X Saturated in Upper 12 Inches Water Marks X No Recorded Data Drift Lines Y Sediment Deposits Field Observations Drainage Patterns in Wetlands Secondary Indicators Depth of Surface Water: 0" Oxidized Root Channels in Upper 12 Inches Water-Stained Leaves Depth to Free Water in Pit: >12" Local Soil Survey Data FAC-Neutral Test Depth to Saturated Soil: 6" Other (Explain in Remarks) Remarks: Wetland hydrology indicators were observed. Page 1 of 2 Wetform) SOILS Map Unit Name (Series and Phase): Pacolet fine sandy loam Mapped Hydric Inclusion? Yes No Map Symbol: PaC Drainage Class: Well Drained Field Observations Confirm Mapped Type: Yes No Taxonomy (Subgroup): Typic hapludults Profile Description Depth (inches) Horizon Matrix Color Munsell Moist) Mottle Color (NIunsell Moist) Mottle Abundance/Contrast Texture, Concretions, Structure, etc. 0-12 10YR 6/6 Loamv sand Hydric Soil Indicators: Histosol Concretions h Organic Content in Surface Layer in Sandy Soils Hi Histic Epipedon g Organic Streaking in Sandy Soils Sulfidic Odor Listed on Local Hydric Soils List Aquic Moisture Regime Listed on National Hydric Soils List Reducing Conditions Gle ed or Low Chroma Colors Other (Explain in Remarks) Remarks: Hydric soil indicators were not observed. WETLAND DETERNVIINATION Hydrophytic Vegetation Present? Yes No Is the Sampling Point within the Wetland? Yes No Wetland Hydrology Present? Yes No Hydric Soils Present? Yes No Remarks: The wetland criteria were not present. The sampling point is not located within a wetland. Page 2 of 2 wAre?r.,,? ENGINEERING CONSULTING SERVICES, LTD. Geotechnical • Construction Materials • Environmental r 1,: John Dorsey =?=No h Carolina Department of Environment and Natural Resources Di fiision of Water Quality Wetland/401 Unit 1621 Mail Service Center Raleigh, North Carolina 27699-1621 Subject: Revised Pre-Construction Notification Application Proposed Commercial Building Winston-Salem, Forsyth County, North Carolina ECS Project G-3434F Dear Mr. Dorsey: September 5, 2000 Please find seven copies of the revised Pre-Construction Notification Application for the above referenced site. Both Mr. Todd St. John and Ms. Jennifer Frye are familiar with the site. The site is approximately 10 acres in area and is located on Westbrook Plaza Drive in Winston-Salem (Figure 1). The site is to be developed with a three story commercial building and associated parking areas. A 401 Water Quality Certification was issued for the project on February 22, 2000 (DWQ Project # 000253). A copy of this certification is included with this package. Tributaries of Little Creek cross the site. Approximately 294 linear feet of intermittent stream channel will be impacted by the construction of a stormwater pond. The stream will be diverted around the pond in order to avoid treating off-site stormwater in the pond. The intermittent stream channel will be graded during construction of the pond. The stream currently enters the site through a 30" RCP. The stream was designated as intermittent by Ms. Jennifer Frye of the North Carolina Division of Water Quality in October 1999. Approximately 147.5 linear feet of perennial stream channel will be impacted by the construction of a roadway/dam. In order to minimize the impact to the perennial portion of the stream, the roadway/dam have been combined. The proposed development is illustrated on the attached Grading and Erosion Control Plan prepared by Stimmel Associates, P.A. We are requesting a 401 Water Quality Certification for the impact to 294 linear feet of intermittent stream channel and 147.5 linear feet of perennial stream channel. As the impact to the perennial portion of the stream channel is less than 150 linear feet, we are not including a mitigation plan with this request. A stormwater management plan has been designed to remove 85 % total suspended solids. The intermittent stream on the site is very low quality. It is our opinion, that the stormwater pond will be 5-C Dundas Circle, Greensboro, NC 27407 • (336) 856-7150 • Fax (336) 856-7160 Offices: Aberdeen, MD • Atlanta, GA • Austin, TX • Baltimore, MD • Chantilly, VA • Charlotte, NC • Chicago, IL • Frederick, MD • Fredericksburg, VA • Greensboro, NC • Greenville, SC • Norfolk, VA • Raleigh, NC • Richmond, VA • Roanoke, VA • Williamsburg, VA • Wilmington, NC Section 401 Permitting Proposed Commercial Building ECS Project G-3434F more effective in preserving water quality. The stormwater pond design specifications have been forwarded to Mr. Todd St. John for his review. Please feel free to contact me at (336) 856-7150 if you have any questions concerning this request or if additional information is required. Thank you in advance for your timely consideration of this matter. Sincerely, ENGINEERING CONSULTING SERVICES, LTD. 0W Denise M. Poulos, LSS Principal Scientist Attachment: Pre-Construction Notification Application $475.00 Application Fee 2 DWQ ID: _ CORPS ACTION ID: NATIONWIDE PERMIT REQUESTED (PROVIDE NATIONWIDE PERMIT #) 14,26 PRE-CONSTRUCTION NOTIFICATION APPLICATION FOR NATIONWIDE PERMITS THAT REQUIRE: 1. NOTIFICATION TO THE CORPS OF ENGINEERS 2. APPLICATION FOR SECTION 401 CERTIFICATION 3. COORDINATION WITH THE NC DIVISION OF COASTAL MANAGEMENT SEND THE ORIGINAL AND (1) COPY OF THIS COMPLETED FORM TO THE APPROPRIATE FIELD OFFICE OF THE CORPS OF ENGINEERS (SEE AGENCY ADDRESSES SHEET). SEVEN (7) COPIES MUST BE SENT TO THE NC DIVISION OF WATER QUALITY ATTN• JOHN DORNEY, 4401 REEDY CREEK ROAD, RALEIGH, NC 27607. PLEASE PRINT OR TYPE. 1. OWNER'S NAME: Mr Scott Boldt, KDA Financial 2. MAILING ADDRESS: 350 Franklin Road SUBDIVISION NAME CITY: Marietta STATE: Geor is ZIP CODE: 30067 PROJECT LOCATION ADDRESS, INCLUDING SUBDIVISION NAME (IF DIFFERENT FROM MAILING ADDRESS ABOVE): The proiect is located on Westbrook Plaza Drive in Winston-Salem. 3. TELEPHONE NUMBER: (HOME) _ (WORK) (770) 421-1532 4. IF APPLICABLE: AGENT'S NAME OR RESPONSIBLE CORPORATE OFFICIAL, ADDRESS, PHONE NUMBER: Denise M Poulos Engineering Consulting Services Ltd 5-C Dundas Circle Greensboro NC 27407, (336) 856-7150 5. LOCATION OF WORK (PROVIDE A MAP, PREFERABLY A COPY OF USGS TOPOGRAPHIC MAP OR AERIAL PHOTOGRAPHY WITH SCALE): COUNTY: Forsyth - NEAREST TOWN: Winston-Salem SPECIFIC LOCATION (INCLUDE ROAD NUMBERS, LANDMARKS, ETC.) The site is located on Westbrook Plaza Drive in Winston-Salem. 6. IMPACTED OR NEAREST STREAM/RIVER: Little Creek/Muddy Creek RIVER BASIN: Yadkin/PeeDee 7. (a) IS PROJECT LOCATED NEAR WATER CLASSIFIED AS TROUT, TIDAL SALTWATER, (SA), HIGH QUALITY WATERS (HQW), OUTSTANDING RESOURCE WATERS (ORW), WATER SUPPLY (WS-I OR WS-II)? YES ? NO X IF YES, EXPLAIN: (b) IS THE PROJECT LOCATED WITHIN A NORTH CAROLINA DIVISION OF COASTAL MANAGEMENT AREA OF ENVIRONMENTAL CONCERN (AEC)? YES ? NO ? (c) IF THE PROJECT IS LOCATED WITHIN A COASTAL COUNTY (SEE PAGE 7 FOR LIST OF COASTAL COUNTIES), WHAT IS THE LAND USE PLAN (LUP) DESIGNATION? 8. (a) HAVE ANY SECTION 404 PERMITS BEEN PREVIOUSLY REQUESTED FOR USE ON THIS PROJECT? YES X NO IF YES, PROVIDE ACTION I.D. NUMBER OF PREVIOUS PERMIT AND ANY ADDITIONAL INFORMATION (INCLUDE PHOTOCOPY OF 401 CERTIFICATION): 200020694 (b) ARE ADDITIONAL PERMIT REQUESTS EXPECTED FOR THIS PROPERTY IN THE FUTURE? YES ? NO X IF YES, DESCRIBE ANTICIPATED WORK: (a) ESTIMATED TOTAL NUMBERS OF ACRES IN TRACT OF LAND: 10 Acres (b) ESTIMATED TOTAL NUMBER OF ACRES OF WETLANDS LOCATED ON PROJECT SITE: A tributary of Little Creek crosses the site. There are no wetlands present on the site. 10. (a) NUMBER OF ACRES OF WETLANDS IMPACTED BY THE PROPOSED PROJECT BY: FILLING: _ EXCAVATION: FLOODING: OTHER: DRAINAGE: TOTAL ACRES TO BE IMPACTED: NA (b) (1) STREAM CHANNEL TO BE IMPACTED BY THE PROPOSED PROJECT (IF RELOCATED, PROVIDE DISTANCE BOTH BEFORE AND AFTER RELOCATION: LENGTH BEFORE: _ FT AFTER: _ FT WIDTH BEFORE (based on normal high water contours):_ FT AVERAGE DEPTH BEFORE: _ FT AFTER: _ FT (b) (2) STREAM CHANNEL IMPACTS WILL RESULT FROM: (CHECK ALL THAT APPLY) OPEN CHANNEL RELOCATION: _ PLACEMENT OF PIPE IN CHANNEL: X CHANNEL EXCAVATION: CONSTRUCTION OF A DAM/FLOODING: X OTHER: Diversion 11. IF CONSTRUCTION OF A POND IS PROPOSED, WHAT IS THE SIZE OF THE WATERSHED DRAINING TO THE POND? 30.3 acres WHAT IS THE EXPECTED POND SURFACE AREA? 0.5 acres 12. DESCRIPTION OF PROPOSED WORK INCLUDING DISCUSSION OF TYPE OF MECHANICAL EQUIPMENT TO BE USED? (ATTACH PLANS; 81/2 BY 1 1 DRAWINGS ONLY) The site is to be developed with a three story office building and parking lots. The building and parking lots will be constructed in high ground Only a stormwater pond and a roadway will impact the stream located on the site Truck loaders excavators backhoes bulldozers etc will be used to develop the site. 13. PURPOSE OF PROPOSED WORK: The site is to be developed with a three story office building and a stormwater pond. 14. STATE REASONS WHY IT IS BELIEVED THAT THIS ACTIVITY MUST BE CARRIED OUT IN WETLANDS (INCLUDE ANY MEASURES TAKEN TO MINIMIZE WETLAND IMPACTS) Due to the topography of the site a stormwater pond will be constructed near the eastern boundary. This will impact approximately 294 if of intermittent stream channel due to diversion and fill. To minimize impacts the dam/access road have been combined The dam/road will impact approximately 147.5 If of perennial stream channel. 15. YOU ARE REQUIRED TO CONTACT THE US FISH AND WILDLIFE SERVICE AND/OR NATIONAL MARINE FISHERIES SERVICE REGARDING THE PRESENCE OF ANY FEDERALLY LISTED OR PROPOSED FOR LISTING ENDANGERED OR THREATENED SPECIES OR CRITICAL HABITAT IN THE PERMIT AREA THAT MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED: 16. YOU ARE REQUIRED TO CONTACT THE STATE HISTORIC PRESERVATION OFFICER (SHPO) REGARDING THE PRESENCE OF HISTORIC PROPERTIES IN THE PERMIT AREA WHICH MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED Feb-07-00 04:35P P.Ol rto-ur-cuuu ii:[oaa rrw-tMGINEERIMG CCMSULTIMG SRVS LTD +3368557160 T-163 P.002/002 F-346 l7_ DOES THE PROJECT INVOLVE AN EJO?ENDTTURE OF PUBLIC FUNDS OR THE USE OF PUBLIC (STATE) LAND? YES ? NO X (IF NO, GO TO 16) (a) IF YES, DOES THE PROJECT REQUIRE PREPARATION OF AN ENVIRONMENTAL DOCUMENT PURSUANT TO THE REQUIREMENTS OF THE NORT7 i CAROLINA ENVIRONMENTAL POLICY ACT? YES ? NO ? (b) IF YES, HAS THE DOCUMENT BEEN REVIEWED THROUGH THE NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CLEARINGHOUSE YES ? NO ? IF ANSWER 17b IS YES, THEN SUBMIT APPROPRIATE DOCUMENTATION FROM THE STATE CLEARINGHOUSE WITH THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT, QUESTIONS REGARDING THE STATE CLEARINGHOUSE REVIEW PROCESS SHOULD BE DIRECTED TO MS. CHRYS BAGGETT, DIRECTOR STATE CLEARINGHOUSE, NORTH CAROLINA DEPARTMENT OF ADMINISTRATION, I I6 WEST JONES STREET, RALEIGH, NORTH CAROLINA 27603-8003. TELEPHONE (919) 733-6369. 8 THE FOLLOWING ITEMS SHOULD BE INCLUDED WITH THIS APPLICATION IF PROPOSED ACTIVITY INVOLVES THE DISCHARGE OF EXCAVATED OF FILL MATERIAL INTO WETLANDS: (a) WETLAND DELINEATION MAP SHOWING ALL WETLANDS, STREAMS, LAKES, AND PONDS ON THE PROPERTY (FOR NATIONWIDE PERMIT NUMBERS 14, 13, 21, 26, 29, AND 33). ALL STREAM (INTERMITTENT AND PERMANENT) ON THE PROPERTY MUST BE SHOWN ON THE MAP. MAP SCALES SHOULD BE 1 INCH EQUALS 50 FEET OF 1 INCH EQUALS 100 FEET OF THEIR EQUIVALENT. (b) IF AVAILABLE, REPRESENTATIVE PHOTOGRAPH OF WETLANDS TO BE IMPACTED BY PROJECT. (c) IF DELINEATION WAS PERFORMED BY A CONSULTANT, INCLUDE ALL DATA SHEETS RELEVANT TO THE PLACEMENT OF THE DELINEATION LINE. (d) ATTACH A COPY OF THE STORMWATER MANAGEMENT PLAN IF REQUIRED. (e) WHAT IS LAND USE OF SURROUNDING PROPERTY" RcsidewfaUcommomial (I) IF APPLICABLE, WHAT IS PROPOSED METHOD OF SEWAGE DISPOSAL? Sani sewer svstmn SIGNED AND DATM AGENT AUTHORIZATION LETTER, IF APPLICABLE. NOTE: WETLANDS OR WATERS OF TEE US MAY NOT BE IMPACTED PRIOR TO: 1. ISSUANCE OF A SECTION 404 CORPS OF ENGINEERS PERMIT. 2. ETTHBR THE ISSUANCE OR WAIVER OF A 401 DMSION OF WATER QUALITY CERTIFICATION, AND 3. (IM THE TWENTY COASTAL COUNTIES ONLY), A LETTER FROM THE NORTH LIMA DIVISION OF COASTAL MANAGEMENT STATING THE PROPOSED t TY IS CONSISTENT WITH THE NORTH CAROLINA COASTAL MANAGEMENT oa SIGNATURE DATE (AGENTS SIGNATURE VALID ONLY IF AUTHORIZATION LETTER FROM THE OWNER IS PROVIDED). Feb-28-00 05:31P State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director Opm h mom NCDENR NORTH CAROI..INA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES February 22, 2000 Forsyth County DWQ Project (1000253 APPROVAL of 401 Water Quality Certification with Additional Conditions Scutt Boldt, KDA Financial 350 Franklin Road Marietta. GA 30067 P.02 Dear Mr. Buldt: You have our approval, in accordance with the attached conditions and those listed below, to construct a pond and a road crossing which will impact a total of 452 feet of stream channel for the purpose of commercial construction in Forsyth County, as you described in your application received by the Division of Water Quality on February 11, 2000. After reviewing your application, we have decided that this action is covered by General Water Quality Certification Numbers 3103 and 3108. This certification allows you to use Nationwide Permit Numbers 14 and 26 when the Corps of Engineers issues it. In addition, you should get any other federal, state or local permits before you go ahead with your project including (but not limited to) Sediment and Erosion Control. Coastal Stormwater, Non-Discharge and Water Supply Water shed regulations. This approval will expire when the accompanying 404 or CAMA permit expires unless otherwise specified in the General Certification. This approval is only valid for the purpose and design that you described in your application. If you change your project, you must notify us and you may be required to send us a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter and is thereby responsible for complying with all conditions. if total wetland rills for this pmject (now or in the future) exceed one acre, compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to be valid you must follow the conditions below and those listed in the attached certification. 1. An additional condition is that a final, written stormwatermanagemcnt plan shall be approved by this Office before the impacts specified in this Certification occur. The stormwater management plan must include plans and specifications for stormwater management facilities designed to remove 85176 TSS according to the most recent version of the NC DENR Stormwater Best Management Practices Manual. Also, before any pcrn=cnt building is occupied at the subject site, the facilities, as approved by this Office, shall be constructed and operational, and the stormwater management plan, as approved by this Office, shall be implemented. If you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter 1508 of the North Carolina General Statutes to the Office of Administrative Hearings, P.O. Box 27447, Raleigh, N.C. 276 1 1-7447. This certification and its conditions arc final and binding unless you ask for a hearing. This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone John Dorney at 919-733-9646. Attachment cc: Corps of Engineers Raleigh Field Office Winston-Salem DWQ Regional Office Denis Poulos, Engineering Cunsulting Services, 5-C Dundas Circle, Greensboro. NC 27407 File Copy Central Files 000253 ( mw ?'1? lO noes f ? ?? •,`?"_.?? ? ,\ \ '?/\y .•_ >?-?' -- ? ? N? ?' G \• ?1 _ ? ,r% ?i: may': t ?? ? `?\ \ ?? ?? ? \•?\ ? -? ?r "` rte; ,r,?, .'?ii? ? ?1 .'?\'` „I •'ll• ?'l'1? _?.??. it ` ; /• •? 1 l 1. /?( ^? ~? 838 III /r © u O J ? L ? f •/'k .- 1. SOURCE: C FIGURE 1 USGS TOPOGRAPHIC MAP, 's LTD SITE LOCATION MAP WINSTON-SALEM WEST, NC PROPOSED COMMERCIAL QUADRANGLE, DATED 1950 AND REVISED 1994 ENGINEERING BUILDING WINSTON-SALEM, NC SCALE: I"= 2,000' CONSULTING SERVICES,LTD ECS PROJECT G-3434F DATA FORM ROUTINE WETLAND DETERMINATION (1987 COE Wetlands Delineation Manual) Project/Site: Approximate 12 Acre Tract - I-40 @ Stratford Road Project No: Date: October 4, 1999 Applicant/Owner: KDA Financial County: Forsyth Investigators: Denise M. Poulos/ ECS, LTD. G-3434 State: North Carolina Plot ID: Data Point I Do Normal Circumstances exist on the site? Yes Yo Community ID: Is the site significantly disturbed (Atypical Situation:)'. Yes No Transect ID: Is the area a potential Problem Area? Yes No Field Location: Near SB-20 (If needed, explain on the reverse side) VEGETATION Dominant Plant Species (Latin/Common) Stratum Indicator Plant Species (Latin/Common) Stratum Indicator i I ens sp. mpat Touch-me-not Herb FACW n radicans d d i T ro en co ox Poison ivy Herb FAC nica i L cera japo on Japanese honeysuckle lia dif t V i Vine FAC- o un s ro it Muscadine grape Vine FAC Percent of Dominant Species that are OBL, FACW or FAC: FAC Neutral: (excluding FAC-) 100% Numeric Index: Remarks: The dominant vegetation is hydro hytic. HYDROLOGY Recorded Data (Describe in Remarks): Wetland Hydrology Indicators Stream, Lake or Tide Gauge Primary Indicators Aerial Photographs Inundated Other K Saturated in Upper 12 Inches Water Nlarks X No Recorded Data Drift Lines X Sediment Deposits Field Observations Drainage Patterns in Wetlands Secondary Indicators Depth of Surface Water: 0" Oxidized Root Channels in Upper 12 Inches Water-Stained Leaves Depth to Free Water in Pit: >12" Local Soil Survey Data FAC-Neutral Test Depth to Saturated Soil: 6" Other (Explain in Remarks) Remarks: 11 Wetland hydrology indicators were ooservea. Page 1 of 2 Wetform) SOILS Map Unit Name (Series and Phase): Pacolet fine sandy loam Mapped Hydric Inclusion? Yes Yo Map Symbol: PaC Drainage Class: Well Drained Field Observations Confirm Mapped Type: Yes No Taxonomy (Subgroup): Typic hapludults Profile Description Depth (inches) Horizon Matrix Color NIunsell Moist) Mottle Color (llunsell Moist) Mottle Abundance/Contrast Texture, Concretions, Structure, etc.- 0-12 10YR 6/6 Loamv sand I I Hydric Soil Indicators: Concretions Histosol h Organic Content in Surface Layer in Sandy Soils Hi Histic Epipedon g Organic Streaking in Sandy Soils Sulfidic Odor Listed on Local Hydric Soils List Aquic Moisture Regime Listed on National Hydric Soils List Reducing Conditions Gle ed or Low Chroma Colors Other (Explain in Remarks) Remarks: Hydric soil indicators were not observed. WETLAND DETERNUNATION Is the Sampling Point within the Wetland? Yes Yo phytic Vegetation Present? Yes 7 d Hydrology Present'. Yes 1; 4 F 4 Soils Present? Yes Remarks: The wetland criteria were not present. The sampling point is not located within a wetland. 1 11 Page 2 of 2 ENGINEERING CONSULTING SERVICES, LTD. Geotechnical • Construction Materials • Environmental 17 i 0) ;M?_'John Dorney ?:I am lrrh Carolina Department of Environment and Natural Resources p?.vision of Water Quality W?tland/401 Unit 1621 Mail Service Center Raleigh, North Carolina 27699-1621 Subject: Revised Pre-Construction Notification Application Proposed Commercial Building Winston-Salem, Forsyth County, North Carolina ECS Project G-3434F Dear Mr. Dorney: September 5, 2000 Please find seven copies of the revised Pre-Construction Notification Application for the above referenced site. Both Mr. Todd St. John and Ms. Jennifer Frye are familiar with the site. The site is approximately 10 acres in area and is located on Westbrook Plaza Drive in Winston-Salem (Figure 1). The site is to be developed with a three story commercial building and associated parking areas. A 401 Water Quality Certification was issued for the project on February 22, 2000 (DWQ Project # 000253). A copy of this certification is included with this package. Tributaries of Little Creek cross the site. Approximately 294 linear feet of intermittent stream channel will be impacted by the construction of a stormwater pond. The stream will be diverted around the pond in order to avoid treating off-site stormwater in the pond. The intermittent stream channel will be graded during construction of the pond. The stream currently enters the site through a 30" RCP. The stream was designated as intermittent by Ms. Jennifer Frye of the North Carolina Division of Water Quality in October 1999. Approximately 147.5 linear feet of perennial stream channel will be impacted by the construction of a roadway/dam. In order to minimize the impact to the perennial portion of the stream, the roadway/dam have been combined. The proposed development is illustrated on the attached Grading and Erosion Control Plan prepared by Stimmel Associates, P.A. We are requesting a 401 Water Quality Certification for the impact to 294 linear feet of intermittent stream channel and 147.5 linear feet of perennial stream channel. As the impact to the perennial portion of the stream channel is less than 150 linear feet, we are not including a mitigation plan with this request. A stormwater management plan has been designed to remove 85 % total suspended solids. The intermittent stream on the site is very low quality. It is our opinion, that the stormwater pond will be 5-C Dundas Circle, Greensboro, NC 27407 • (336) 856-7150 • Fax (336) 856-7160 Offices: Aberdeen, MD • Atlanta, GA • Austin, TX • Baltimore, MD • Chantilly, VA • Charlotte, NC • Chicago, IL • Frederick, MD • Fredericksburg, VA • Greensboro, NC • Greenville, SC • Norfolk, VA • Raleigh, NC • Richmond, VA • Roanoke, VA • Williamsburg, VA • Wilmington, NC Section 401 Permitting Proposed Commercial Building ECS Project G-3434F more effective in preserving water quality. The stormwater pond design specifications have been forwarded to Mr. Todd St. John for his review. Please feel free to contact me at (336) 856-7150 if you have any questions concerning this request or if additional information is required. Thank you in advance for your timely consideration of this matter.' Sincerely, ENGINEERING CONSULTING SERVICES, LTD. , Denise M. Poulos, LSS Principal Scientist Attachment: Pre-Construction Notification Application $475.00 Application Fee 2 DWQ ID: _ CORPS ACTION ID: NATIONWIDE PERMIT REQUESTED (PROVIDE NATIONWIDE PERMIT #) 14,26 PRE-CONSTRUCTION NOTIFICATION APPLICATION FOR NATIONWIDE PERMITS THAT REQUIRE: 1. NOTIFICATION TO THE CORPS OF ENGINEERS 2. APPLICATION FOR SECTION 401 CERTIFICATION 3. COORDINATION WITH THE NC DIVISION OF COASTAL MANAGEMENT SEND THE ORIGINAL AND (1) COPY OF THIS COMPLETED FORM TO THE APPROPRIATE FIELD OFFICE OF THE CORPS OF ENGINEERS (SEE AGENCY ADDRESSES SHEET). SEVEN (7) COPIES MUST BE SENT TO THE NC DIVISION OF WATER QUALITY ATTN• JOHN DORNEY, 4401 REEDY CREEK ROAD, RALEIGH, NC 27607. PLEASE PRINT OR TYPE. 1. OWNER'S NAME: Mr. Scott Boldt, KDA Financial 2. MAILING ADDRESS: 350 Franklin Road SUBDIVISION NAME CITY: Marietta STATE: Geor is ZIP CODE: 30067 PROJECT LOCATION ADDRESS, INCLUDING SUBDIVISION NAME (IF DIFFERENT FROM MAILING ADDRESS ABOVE): The project is located on Westbrook Plaza Drive in Winston-Salem. 3. TELEPHONE NUMBER: (HOME) _ (WORK) (770) 421-1532 4. IF APPLICABLE: AGENT'S NAME OR RESPONSIBLE CORPORATE OFFICIAL, ADDRESS, PHONE NUMBER: Denise M Poulos Engineerine Consulting Services Ltd 5-C Dundas Circle Greensboro NC 27407, (336) 856-7150 5. LOCATION OF WORK (PROVIDE A MAP, PREFERABLY A COPY OF USGS TOPOGRAPHIC MAP OR AERIAL PHOTOGRAPHY WITH SCALE): COUNTY: Forsyth - NEAREST TOWN: Winston-Salem SPECIFIC LOCATION (INCLUDE ROAD NUMBERS, LANDMARKS, ETC.) The site is located on Westbrook Plaza Drive in Winston-Salem. 6. IMPACTED OR NEAREST STREAM/RIVER: Little Creek/Muddy Creek RIVER BASIN: Yadkin/PeeDee 7. (a) IS PROJECT LOCATED NEAR WATER CLASSIFIED AS TROUT, TIDAL SALTWATER, (SA), HIGH QUALITY WATERS (HQW), OUTSTANDING RESOURCE WATERS (ORW), WATER SUPPLY (WS-I OR WS-II)? YES ? NO X IF YES, EXPLAIN: (b) IS THE PROJECT LOCATED WITHIN A NORTH CAROLINA DIVISION OF COASTAL MANAGEMENT AREA OF ENVIRONMENTAL CONCERN (AEC)? YES ? NO ? (c) IF THE PROJECT IS LOCATED WITHIN A COASTAL COUNTY (SEE PAGE 7 FOR LIST OF COASTAL COUNTIES), WHAT IS THE LAND USE PLAN (LUP) DESIGNATION? 8. (a) HAVE ANY SECTION 404 PERMITS BEEN PREVIOUSLY REQUESTED FOR USE ON THIS PROJECT? YES X NO IF YES, PROVIDE ACTION I.D. NUMBER OF PREVIOUS PERMIT AND ANY ADDITIONAL INFORMATION (INCLUDE PHOTOCOPY OF 401 CERTIFICATION): 200020694 (b) ARE ADDITIONAL PERMIT REQUESTS EXPECTED FOR THIS PROPERTY IN THE FUTURE? YES ? NO X IF YES, DESCRIBE ANTICIPATED WORK: (a) ESTIMATED TOTAL NUMBERS OF ACRES IN TRACT OF LAND: 10 Acres (b) ESTIMATED TOTAL NUMBER OF ACRES OF WETLANDS LOCATED ON PROJECT SITE: A tributary of Little Creek crosses the site There are no wetlands present on the site. 10. (a) NUMBER OF ACRES OF WETLANDS IMPACTED BY THE PROPOSED PROJECT BY: FILLING: _ EXCAVATION: FLOODING: _ OTHER: DRAINAGE: TOTAL ACRES TO BE IMPACTED: NA (b) (1) STREAM CHANNEL TO BE IMPACTED BY THE PROPOSED PROJECT (IF RELOCATED, PROVIDE DISTANCE BOTH BEFORE AND AFTER RELOCATION: LENGTH BEFORE: _ FT AFTER: _ FT WIDTH BEFORE (based on normal high water contours): _ FT AVERAGE DEPTH BEFORE: _ FT AFTER: - FT (b) (2) STREAM CHANNEL IMPACTS WILL RESULT FROM: (CHECK ALL THAT APPLY) OPEN CHANNEL RELOCATION: - PLACEMENT OF PIPE IN CHANNEL: X CHANNEL EXCAVATION: _ CONSTRUCTION OF A DAM/FLOODING: X OTHER: Diversion 11. IF CONSTRUCTION OF A POND IS PROPOSED, WHAT IS THE SIZE OF THE WATERSHED DRAINING TO THE POND? 30.3 acres WHAT IS THE EXPECTED POND SURFACE AREA? 0.5 acres 12. DESCRIPTION OF PROPOSED WORK INCLUDING DISCUSSION OF TYPE OF MECHANICAL EQUIPMENT TO BE USED? (ATTACH PLANS; 81/2 BY I I DRAWINGS ONLY) The site is to be developed with a three story office building and parking lots The building and parking lots will be constructed in high ground Only a stormwater pond and a roadway will impact the strea_m located on the site Truck loaders excavators backhoes bulldozers etc will be used to develop the site. 13. PURPOSE OF PROPOSED WORK: The site is to be developed with a three story office building and a stormwater pond. 14. STATE REASONS WHY IT IS BELIEVED THAT THIS ACTIVITY MUST BE CARRIED OUT IN WETLANDS (INCLUDE ANY MEASURES TAKEN TO MINIMIZE WETLAND IMPACTS) Due to the topography of the site a stormwater pond will be constructed near the eastern boundary. This will impact a roximatel 294 If of intermittent stream channel due to diversion and fill. To minimize impacts the dam/access road have been combined The dam/road will impact approximately 147.5 If of perennial stream channel. 15. YOU ARE REQUIRED TO CONTACT THE US FISH AND WILDLIFE SERVICE AND/OR NATIONAL MARINE FISHERIES SERVICE REGARDING THE PRESENCE OF ANY FEDERALLY LISTED OR PROPOSED FOR LISTING ENDANGERED OR THREATENED SPECIES OR CRITICAL HABITAT IN THE PERMIT AREA THAT MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED: 16. YOU ARE REQUIRED TO CONTACT THE STATE HISTORIC PRESERVATION OFFICER (SHPO) REGARDING THE PRESENCE OF HISTORIC PROPERTIES IN THE PERMIT AREA WHICH MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED _. Feb-07-00 04:35P P.0 1 r?o-v?-cuuu ii:cnaa wont-tMGIf1EERIMG CCMSULTIMG SRVS LTD +3366567160 T-163 P.002/002 F-346 l7. DOES THE PROJECT INVOLVE AN E7 PENDfTURE OF PUBLIC FUNDS OR THE USE OF PUBLIC (STATE) LAND? YES ? NO X (IF NO, GO TO 16) (a) IF YES, DOES THE PROJECT REQUIRE PREPARATION OF AN ENVIRONMENTAL DOCUMENT PURSUANT TO THE REQUIREMENTS OF THE NORTH CAROLINA ENVIRONMENTAL POLICY ACTT YES ? NO ? (b) IF YES, HAS THE DOCUMENT BEEN REVIEWED THROUGH THE NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CLEARINGHOUSE YES ? NO ? IF ANSWER 17b IS YES, THEN SUBMIT APPROPRIATE DOCUMENTATION FROM THE STATE CLEARINGHOUSE WITH THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT, QUESTIONS REGARDING THE STATE CLEARINGHOUSE REVIEW PROCESS SHOULD BE DIRECTED TO MS. CHRYS BAGGETT, DIRECTOR STATE CLEARINGHOUSE, NORTH CAROLINA DEPARTMENT OF ADMINISTRATTON, 116 WEST JONES STREET, RALEIGH, NORTH CAROLINA 27603-8003. TELEPHONE (919) 733-6369. 1& THE FOLLOWING ITEMS SHOULD BE INCLUDED WITH THIS APPLICATION IF PROPOSED ACTIVITY INVOLVES THE DISCHARGE OF EXCAVATED OF FILL MATERIAL INTO WETLANDS: (a) WETLAND DELINEATION MAP SHOWING ALL WETLANDS, STREAMS, LAKES, AND PONDS ON THE PROPERTY (FOR NATIONWIDE PERMIT NUMBERS 14,13,21,26,29, AND 33). ALL STREAM (INTIUM I IE'N I AND PERMANENT) ON THE PROPERTY MUST BE SHOWN ON THE MAP. MAP SCALES SHOULD BE 1 INCH EQUALS 50 FEET OF I INCH EQUALS 100 FEET OF THEIR EQUIVALENT. (b) IF AVAILABLE, REPRESENTATIVE PHOTOGRAPH OF WETLANDS TO BE IMPACTED BY PROJECT. (c) IP DELINEATION WAS PERFORMED BY A CONSULTANT, INCLUDE ALL DATA SHEETS RELEVANT TO THE PLACEMENT OF THE DELINEATION LINE. (d) ATTACH A COPY OF T13E STORMWATER MANAGEMENT PLAN IF REQUIRED. (c) WHAT IS LAND USE OF SURROUNDING PROPERTY? RaWcatfaUcammarcial M IF APPLICABLE, WHAT IS PROPOSED METHOD OF SEWAGE DISPOSAL? Sani sewer system. SIGNED AND DATED AGENT AUTHORIZATION LETTER, IF APPLICABLE. NOTE: WETLANDS OR WATERS OF THE US MAY NOT BE IMPACTED PRIOR TO- I. ISSUANCE OF A SECTION 404 CORPS OF ENGINEERS PERMIT. 2. EITHER THE ISSUANCE OR WAIVER OF A 401 DIVISION OF WATER QUALITY CERTIFICATION, AND 3. (III THE TWENTY COASTAL COUNTIES ONLY), A LETTER FROM THE NORTH LIMA DIVISION OF COASTAL MANAGEMENT STATING THE PROPOSED F TY IS CONSISTENT WITH THE NORTH CAROLINA COASTAL MANAGEMENT all oa 0 GENTS SIGNATURE DATE (AGENT'S SIGNATURE VALID ONLY IF AUTHORIZATION LETTER FROM THE OWNER IS PROVIDED). Feb-28-00 05:31P State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES' Fchruury 22, 2000 l.-ursyth County DWQ Project # 000253 APPROVAL of 401 Water Quality Certification with Additional Conditions Scott Boldl, KDA Financial 350 Franklin Road Maricttn. GA 30067 P.02 Dear Nir. Boldt: You have our approval, in accordance with the attached conditions and those listed below, to construct a pond and a road crossing which will impact a total of 452 feet of stream channel for the purpose of commercial construction in Forsyth County, as you described in your application received by the Division of Water Quality on February 11, 2000. After reviewing your application. we have decided that this action is covered by General Water Quality Certification Numbers 3103 and 3108. This certification allows you to use Nationwide Permit Numbers 14 and 26 when the Corps of Engineers issues it. In addition, you should get any other federal, state or local permits before you go ahead with your project including (but not limited to) Sediment and Erosion Control, Coastal Stormwater, Non-Discharge and Water Supply Water shed regulations. This approval will expire when the accompanying 404 or CAMA permit expires unless otherwise specified in the General Certification. This approval is only valid for the purpose and design that you described in your application. If you change your project, you must notify us and you may be required to send us a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter and is thereby responsible for complying with all conditions. If total wetland rills for this pmject (now or in the future) exceed one acre, compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to be valid you must follow the conditions below and those listed in the attached certification. I. An additional condition is that a final, written storrawatermanagemcnt plan shall be approved by this Office before the impacts specified in this Certification occur. The stormwater management plan must include plans and specifications for stormwater management facilities designed to remove 85% TSS according to the most recent version of the NC DENR Stormwater Best Management Practices Manual. Also, before any permanent building is occupied at the subject site, the facilities, as approved by this Office, shitll be constructed and operational, and the stormwater management plan, as approved by this Of lice, shall be implemented. If you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter 1508 of the North Carolina General Statutes to the Office of Administrative Hearings, P.O. Box 27447, Raleigh, N.C. 276 1 1-7447. This certification and its conditions arc final and binding unless you ask for a hearing. This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone John Dorney at 919-733-9646. Attachment cc: Corp-, of Engineers Raleigh Field Office Winston-Salem DWQ Regional Office Denis Poulos, Engineering Consulting Services, 5-C Dundas Circle, Greensboro. NC 27407 File Copy Central Files 000253 ? I ?Z.`.// -y fry ?•? ? `? \ 10 862 v1? j t' i ??.. ??\??/ ?I G/ ? ? ? ?,???? •? 1?? 1 ???''? •?' mil: l? ,7 ?\ il? ?r u / a SOURCE: FIGURE 1 USGS TOPOGRAPHIC MAP, LTD SITE LOCATION MAP WINSTON-SALEM WEST, NC PROPOSED COMMERCIAL QUADRANGLE, DATED 1950 AND REVISED 1994 ENGINEERING BUILDING WINSTON-SALEM, NC SCALE: I"= 2,000' CONSULTING SERVICES,LTD ECS PROJECT G-3434F DATA FORM ROUTINE WETLAND DETERI IINATION 1987 COE Wetlands Delineation Manual) Project/Site: Approximate 12 Acre Tract - I-40 @ Stratford Road Project No: Date: October 4, 1999 Applicant/Owner: KDA Financial County: Forsyth Investigators: Denise M. Poulos/ ECS, LTD. G-3434 State: North Carolina Plot ID: Data Point I Do Normal Circumstances exist on the site? Yes No Community ID: Is the site significantly disturbed (Atypical Situation:)? Yes Yo Transect ID: Is the area a potential Problem Area? Yes Yo Field Location: Near SB-20 (If needed, explain on the reverse side) VLULIA11VIl Dominant Plant Species (Latin/Common) Stratum Indicator Plant Species (Latin/Common) Stratum Indicator atiens s Im p. p Touch-me-not Herb FACW icodendron radicans T ox Poison ivy Herb FAC onica icera ja L p on Japanese honeysuckle otundifolia Viti Vine FAC- s r Muscadine grape Vine FAC Percent of Dominant Species that are OBL, FACW or FAC: (excluding FAC-) 100% FAC Neutral: Numeric Index: Remarks: The dominant vegetation is hydro hytic. HYDROLOGY Recorded Data (Describe in Remarks): Wetland Hydrology Indicators Stream, Lake or Tide Gauge Primary Indicators Aerial Photographs Inundated Other X Saturated in Upper 12 Inches Water Marks X No Recorded Data Drift Lines X Sediment Deposits Field Observations Drainage Patterns in Wetlands Secondary Indicators " Oxidized Root Channels in Upper 12 Inches Depth of Surface Water: 0 Water-Stained Leaves Depth to Free Water in Pit: >12" Local Soil Survey Data FAC-Neutral Test Depth to Saturated Soil: 6" Other (Explain in Remarks) Remarks: Wetland hydrology indicators were observed. Page 1 of 2 W etform) SOILS Map Unit Name (Series and Phase): Pacolet fine sandy loam Mapped Hydric Inclusion? Yes No Map Symbol: PaC Drainage Class: Well Drained Field Observations Confirm Mapped Type: Yes No Taxonomy (Subgroup): Typic hapludults Profile Description Depth Matrix Color Mottle Color Mottle (inches) Horizon (Munsell Moist) (Munsell Moist) Abundance/Contrast Texture, Concretions, Structure, etc. 0-12 IOYR 6/6 Loamv sand Hydric Soil Indicators: Histosol Concretions High Organic Content in Surface Layer in Sandy Soils Histic Epipedon anic Streaking in Sandy Soils Or Sulfidic Odor g Listed on Local Hydric Soils List Aquic Moisture Regime Listed on National Hydric Soils List Reducing Conditions Gleved or Low Chroma Colors Other (Explain in Remarks) Remarks: Hydric soil indicators were not observed. I WE1LAIN UUL' lt1AUy1LVAl1Vi Hydrophytic Vegetation Present? Yes No Is the Sampling Point within the Wetland? Yes No Wetland Hydrology Present? Yes No Hydric Soils Present? Yes No Remarks: The wetland criteria were not present. The sampling point is not located within a wetland. Page 2 of 2 f Werform) ENGINEERING CONSULTING SERVICES, LTD. Geotechnical • Construction Materials • Environmental 00117.1 September 5, 2000 Mr. John Dorney North Carolina Department of Environment and Natural Resources Division of Water Quality Wetland/401 Unit 1621 Mail Service Center Raleigh, North Carolina 27699-1621, Subject: Revised Pre-Construction Notification Application Proposed Commercial Building Winston-Salem, Forsyth County, North Carolina ECS Project G-3434F Dear Mr. Domey: PAYMENr RECEiVEQ Please find seven copies of the revised Pre-Construction Notification Application for the above referenced site. Both Mr. Todd St. John and Ms. Jennifer Frye are familiar with the site. The site is approximately 10 acres in area and is located on Westbrook Plaza Drive in Winston-Salem (Figure 1). The site is to be developed with a three story commercial building and associated parking areas. A 401 Water Quality Certification was issued for the project on February 22, 2000 (DWQ Project # 000253). A copy of this certification is included with this package. Tributaries of Little Creek cross the site. Approximately 294 linear feet of intermittent stream channel will be impacted by the construction of a stormwater pond. The stream will be diverted around the pond in order to avoid treating off-site stormwater in the pond. The intermittent stream channel will be graded during construction of the pond. The stream currently enters the site through a 30" RCP. The stream was designated as intermittent by Ms. Jennifer Frye of the North Carolina Division of Water Quality in October 1999. Approximately 147.5 linear feet of perennial stream channel will be impacted by the construction of a roadway/dam. In order to minimize the impact to the perennial portion of the stream, the roadway/dam have been combined. The proposed development is illustrated on the attached Grading and Erosion Control Plan prepared by Stimmel Associates, P.A. We are requesting a 401 Water Quality Certification for the impact to 294 linear feet of intermittent stream channel and 147.5 linear feet of perennial stream channel. As the impact to the perennial portion of the stream channel is less than 150 linear feet, we are not including a mitigation plan with this request. A stormwater management plan to has been designed to remove 85 % total suspended solids. The 5-C Dundas Circle, Greensboro, NC 27407 • (336) 856-7150 • Fax (336) 856-7160 Offices: Aberdeen, MD • Atlanta, GA • Austin, TX • Baltimore, MD • Chantilly, VA • Charlotte, NC • Chicago, IL • Frederick, MD • Fredericksburg, VA • Greensboro, NC • Greenville, SC • Norfolk, VA • Raleigh, NC • Richmond, VA • Roanoke, VA • Williamsburg, VA • Wilmington, NC Section 401 Permitting Proposed Commercial Building ECS Project G-3434F intermittent stream on the site is very low quality. It is our opinion, that the stormwater pond will be more effective in preserving water quality. The stormwater pond design specifications have been forwarded to Mr. Todd St. John for his review. Please feel free to contact me at (336) 856-7150 if you have any questions concerning this request or if additional information is required. Thank you in advance for your timely consideration of this matter. Sincerely, ENGINEERING CONSULTING SERVICES, LTD. Denise M. Poulos, LSS Principal Scientist Attachment: Pre-Construction Notification Application $475.00 Application Fee 2 oa1?? DWQ ID: _ CORPS ACTION ID: NATIONWIDE PERMIT REQUESTED (PROVIDE NATIONWIDE PERMIT #) 14,26 PRE-CONSTRUCTION NOTIFICATION APPLICATION FOR NATIONWIDE PERMITS THAT REQUIRE: 1. NOTIFICATION TO THE CORPS OF ENGINEERS 2. APPLICATION FOR SECTION 401 CERTIFICATION 3. COORDINATION WITH THE NC DIVISION OF COASTAL MANAGEMENT SEND THE ORIGINAL AND (1) COPY OF THIS COMPLETED FORM TO THE APPROPRIATE FIELD OFFICE OF THE CORPS OF ENGINEERS (SEE AGENCY ADDRESSES SHEET). SEVEN (7) COPIES MUST BE SENT TO THE NC DIVISION OF WATER QUALITY ATTN• JOHN DORNEY, 4401 REEDY CREEK ROAD, RALEIGH, NC 27607. PLEASE PRINT OR TYPE. 1. OWNER'S NAME: Mr. Scott Boldt, KDA Financial 2. MAILING ADDRESS: 350 Franklin Road SUBDIVISION NAME CITY: Marietta STATE: Georgia ZIP CODE: 30067 PROJECT LOCATION ADDRESS, INCLUDING SUBDIVISION NAME (IF DIFFERENT FROM MAILING ADDRESS ABOVE): The proiect is located on Westbrook Plaza Drive in Winston-Salem. 3. TELEPHONE NUMBER: (HOME) _ (WORK) (770) 421-1532 4. IF APPLICABLE: AGENT'S NAME OR RESPONSIBLE CORPORATE OFFICIAL, ADDRESS, PHONE NUMBER: Denise M Poulos Engineering Consulting Services Ltd 5-C Dundas Circle Greensboro NC 27407, (336) 856-7150 5. LOCATION OF WORK (PROVIDE A MAP, PREFERABLY A COPY OF USGS TOPOGRAPHIC MAP OR AERIAL PHOTOGRAPHY WITH SCALE): COUNTY: Forsyth - NEAREST TOWN: Winston-Salem SPECIFIC LOCATION (INCLUDE ROAD NUMBERS, LANDMARKS, ETC.) The site is located on Westbrook Plaza Drive in Winston-Salem. 6. IMPACTED OR NEAREST STREAM/RIVER: Little Creek/Muddy Creek RIVER BASIN: Yadkin/PeeDee 7. (a) IS PROJECT LOCATED NEAR WATER CLASSIFIED AS TROUT, TIDAL SALTWATER, (SA), HIGH QUALITY WATERS (HQW), OUTSTANDING RESOURCE WATERS (ORW), WATER SUPPLY (WS-I OR WS-II)? YES ? NO X IF YES, EXPLAIN: (b) IS THE PROJECT LOCATED WITHIN A NORTH CAROLINA DIVISION OF COASTAL MANAGEMENT AREA OF ENVIRONMENTAL CONCERN (AEC)? YES E] NO ? (c) IF THE PROJECT IS LOCATED WITHIN A COASTAL COUNTY (SEE PAGE 7 FOR LIST OF COASTAL COUNTIES), WHAT IS THE LAND USE PLAN (LUP) DESIGNATION? 8. (a) HAVE ANY SECTION 404 PERMITS BEEN PREVIOUSLY REQUESTED FOR USE ON THIS PROJECT? YES X NO IF YES, PROVIDE ACTION I.D. NUMBER OF PREVIOUS PERMIT AND ANY ADDITIONAL INFORMATION (INCLUDE PHOTOCOPY OF 401 CERTIFICATION): 200020694 (b) ARE ADDITIONAL PERMIT REQUESTS EXPECTED FOR THIS PROPERTY IN THE FUTURE? YES ? NO X IF YES, DESCRIBE ANTICIPATED WORK: (a) ESTIMATED TOTAL NUMBERS OF ACRES IN TRACT OF LAND: 10 Acres (b) ESTIMATED TOTAL NUMBER OF ACRES OF WETLANDS LOCATED ON PROJECT SITE: A tributary of Little Creek crosses the site There are no wetlands present on the site. 10. (a) NUMBER OF ACRES OF WETLANDS IMPACTED BY THE PROPOSED PROJECT BY: FILLING: _ EXCAVATION: FLOODING: OTHER : DRAINAGE : TOTAL ACRES TO BE IMPACTED: NA (b) (1) STREAM CHANNEL TO BE IMPACTED BY THE PROPOSED PROJECT (IF RELOCATED, PROVIDE DISTANCE BOTH BEFORE AND AFTER RELOCATION: LENGTH BEFORE: _ FT AFTER: _ FT WIDTH BEFORE (based on normal high water contours): _ FT AVERAGE DEPTH BEFORE: _ FT AFTER: _ FT (b) (2) STREAM CHANNEL IMPACTS WILL RESULT FROM: (CHECK ALL THAT APPLY) OPEN CHANNEL RELOCATION: _ PLACEMENT OF PIPE IN CHANNEL: X CHANNEL EXCAVATION: _ CONSTRUCTION OF A DAM/FLOODING: X OTHER: Diversion 11. IF CONSTRUCTION OF A POND IS PROPOSED, WHAT IS THE SIZE OF THE WATERSHED DRAINING TO THE POND? 30.3 acres WHAT IS THE EXPECTED POND SURFACE AREA? 0.5 acres 12. DESCRIPTION OF PROPOSED WORK INCLUDING DISCUSSION OF TYPE OF MECHANICAL EQUIPMENT TO BE USED? (ATTACH PLANS; 81/2 BY 11 DRAWINGS ONLY) The site is to be developed with a three story office building and parking lots. The building and parking lots will be constructed in high ground Only a stormwater pond and a roadway will impact the stream located on the site Truck loaders excavators backhoes bulldozers etc will be used to develop the site. 13. PURPOSE OF PROPOSED WORK: The site is to be developed with a three story office building and a stormwater pond. 14. STATE REASONS WHY IT IS BELIEVED THAT THIS ACTIVITY MUST BE CARRIED OUT IN WETLANDS (INCLUDE ANY MEASURES TAKEN TO MINIMIZE WETLAND IMPACTS) Due to the topography of the site a stormwater pond will be constructed near the eastern boundary. This will impact approximately 294 If of intermittent stream channel due to diversion and fill. To minimize impacts the dam/access road have been combined The dam/road will impact approximately 147.5 If of perennial stream channel. 15. YOU ARE REQUIRED TO CONTACT THE US FISH AND WILDLIFE SERVICE AND/OR NATIONAL MARINE FISHERIES SERVICE REGARDING THE PRESENCE OF ANY FEDERALLY LISTED OR PROPOSED FOR LISTING ENDANGERED OR THREATENED SPECIES OR CRITICAL HABITAT IN THE PERMIT AREA THAT MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED: 16. YOU ARE REQUIRED TO CONTACT THE STATE HISTORIC PRESERVATION OFFICER (SHPO) REGARDING THE PRESENCE OF HISTORIC PROPERTIES IN THE PERMIT AREA WHICH MAY BE AFFECTED BY THE PROPOSED PROJECT. DATE CONTACTED _. Feb va-vi-0o 04:35P P P_Ol o rcv-tnGIMEERING CONSULTING SRVS LTD #3368567160 T-163 P.002/002 F-346 ?7. DOES THE PROJECT INVOLVE AN E 0MITURE OF PUBLIC FUNDS OR THE USE OF PUBLIC (STATE) LAND? YES ? NO X (IF NO, GO TO 16) (a) IF YES, DOES THE PROJECT REQUIRE PREPARATION OF AN ENVIRONMENTAL DOCUMENT PURSUANT TO THE REQUIREMENTS OF THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT? YES ? NO ? (b) IF YES, HAS THE DOCUMENT BEEN REVIEWED THROUGH THE NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CLEARINGHOUSE YES ? NO [] IF ANSWER 17b IS YES, THEN SUBMIT APPROPRIATE DOCUMENTATION FROM THE STATE CLEARINGHOUSE WITH THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT. QUESTIONS REGARDING THE STATE CLEARINGHOUSE REVIEW PROCESS SHOULD BE DIRECTED TO MS. CHRYS BAGGETT, DIRECTOR STATE CLEARINGHOUSE, NORTH CAROLINA DEPARTMENT OF ADMIMSTRATTON, 116 WEST JONES STREET, RALEIGH, NORTH CAROLINA 27603-8003. TELEPHONE (919) 733-6369. 1 B THE FOLLOWING ITEMS SHOULD BE INCLUDED WITH THIS APPLICATION IF PROPOSED ACTIVITY INVOLVES THE DISCHARGE OF EXCAVATED OF FILL MATERIAL INTO WETLANDS: (a) WETLAND DELINEATION MAP SHOWING ALL WETLANDS, STREAMS, LAKES, AND PONDS ON THE PROPERTY (FOR NATIONWIDE PERMIT NUMBERS 14,1$,21,26,29, AND 38). ALL STREAM (DfIM MITTENT AND PERMANENT) ON THE PROPERTY MUST BE SHOWN ON THE MAP. MAP SCALES SHOULD BE 1 INCH EQUALS 50 FEET OF I INCH EQUALS 100 FEET OF THEIR EQUIVALENT. (b) IF AVAILABLE, REPRESENTATIVE PHOTOGRAPH OF WETLANDS TO BE IMPACTED BY PROJECT. (c) IF DELINEATION WAS PERFORMED BY A CONSULTANT, INCLUDE ALL DATA SHEETS RELEVANT TO THE PLACEMENT OF THE DELINEATION LINE. (d) ATTACH A COPY OF THE STORMWATER MANAGEMENT PLAN IF REQUIRED. (c) WHAT IS LAND USE OF SURROUNDING PROPERTY? RoWentlaVcommercial (f) IF APPLICABLE, WHAT IS PROPOSED METHOD OF SEWAGE DISPOSAL? an3 = sewer system. SIGNED AND DAZED AGENT AUTHORIZATION LETTER, IF APPLICABLE. NOTE: WETLANDS OR WATERS OF THE US MAY NOT BE IMPACTED PRIOR TO: 1. ISSUANCE OF A SECTION 404 CORPS OF ENGINEERS PERMIT. 2. EITHER THE ISSUANCE OR WAIVER OF A 401 DIVISION OF WATER QUALITY CERTIFICATION, AND 3. (IN THE TWENTY COASTAL COU111 B ONLY), A LETTER FROM THE NORTH CAWLINA DMSION OF COASTAL MANAGEMENT STATING THE PROPOSED yt- S CONSISTENT WITH THE NORTH CAROLINA COASTAL MANAGEMENT oa SIGNATURE DATE (AGENT'S SIGNATURE VALID ONLY IF AUTHORIZATION LETTER FROM THE OWNER IS PROVIDED). Feb-28-00 05:31P State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director 1 ! • NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES February 22, 2000 I'ursyth County DWQ Project # 000253 APPROVAL of 401 Water Quality Certification with Additional Conditions Scutt Boldt, KDA Financial 350 Franklin Road Marietta. GA 30067 P.02 Dear Mr. Boldt: You have our approval, in accordance with the attached conditions and those listed below, to construct a pond and a road crossing which will impact a total of 452 feet of stream channel for the purpose of commercial construction in Forsyth County, as you described in your application received by the Division of Water Quality on February 11, 2000. After reviewing your application, we have decided that this action is covered by General Water Quality Certification Numbers 3103 and 3108. This certification allows you to use Nationwide Permit Numbers 14 and 26 when the Corps of Engineers issues it. In addition, you should get any other federal, state or local permits before you go ahead with your project including (but not limited to) Sediment and Erosion Control, Coastal Stormwater, Non-Discharge and Water Supply Water shed regulations. This approval will expire when the accompanying 404 or CAMA permit expires unless otherwise specified in the General Certification. This approval is only valid for the purpose and design that you described in your application. If you change your project, you must notify us and you may be required to send us a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter and is thereby responsible for complying with all conditions. If total wetland fills for this pmject (now or in the future) exceed one acre, compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to be valid you must follow the conditions below and those listed in the attached certification. 1. An additional condition is that a final, written stormwater management plan shall be approved by this Office before the impacts specified in this Certification occur. The stormwater management plan must include plans and specifications for stormwater management facilities designed to remove 85% TSS according to the most recent version of the NC DENR Stormwater Best Management Practices Manual. Also, before any permanent building is occupied at the subject site, the facilities, as approved by this Office, shall be constructed and operational, and the stormwater management plan, as approved by this Office, shall be implemented. ll' you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter 1506 of the North Carolina General Statutes to the Office of Administrative Hearings, P.O. Box 27447, Raleigh, N.C. 276 1 1-7447. This certification and its conditions are final and binding unless you ask for a hearing. This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone John Domey at 919-733-9646. Attachment cc: Corps of Engineers Raleigh Field Office Winston-Salem DWQ Regional Office Denis Poulos, Engineering Consulting Services, 5-C Dundas Circle, Greensboro, NC 27407 File Copy Central Files 000253 I •? ? ? ?, '^?? - ??? ?????? ? iii - ' '. ? ? / , ? , ITE J -___? J -??? /' ,fit ? ?\ .\5,.:1???. , •? it '. r• •r I ?(/ I V?-? ,.?J.\? .u,z '?? ?? ,'`? t ,ez?•• a .?? o / i ?l\ ?'Jlr llrra! 0 SOURCE: 9 FIGURE 1 USGS TOPOGRAPHIC MAP, SLTD SITE LOCATION MAP WINSTON-SALEM WEST, NC PROPOSED COMMERCIAL QUADRANGLE, DATED 1950 AND E N G I N E E R I N G BUILDING NC WINSTON-SALEM REVISED 1994 000' SCALE: I"= 2 CONSULTING , ECS PROJECT G-3434F , SERVICES,LTD DATA FORXN1 ROUTINE WETLAND DETERMINATION 1987 COE Wetlands Delineation Manual Project/Site: Approximate 12 Acre Tract - I40 @ Stratford Road Project No: Date: October 4, 1999 Applicant/Owner: KDA Financial County: Forsyth Investigators: Denise M. Poulos/ ECS, LTD. G-3434 State: North Carolina Plot ID: Data Point I HYDROLOGY Recorded Data (Describe in Remarks): Wetland Hydrology Indicators Stream, Lake or Tide Gauge Primary Indicators Aerial Photographs Inundated Other _X Saturated in Upper 12 Inches Water Marks X No Recorded Data Drift Lines X Sediment Deposits Field Observations Drainage Patterns in Wetlands Secondary Indicators Depth of Surface Water: 0" Oxidized Root Channels in Upper 12 Inches Water-Stained Leaves Depth to Free Water in Pit: >12" Local Soil Survey Data FAC-Neutral Test Depth to Saturated Soil: 6" Other (Explain in Remarks) Remarks: Wetland hydrology indicators were observed. (Wetform) Page 1 of 2 Do Normal Circumstances exist on the site? Yes No Community ID: Is the site significantly disturbed (Atypical Situation:)? Yes No Transect ID: Is the area a potential Problem Area? Yes No Field Location: Near SB-20 (If needed, explain on the reverse side) SOILS Map Unit Name (Series and Phase): Pacolet fine sandy loam Mapped Hydric Inclusion? Yes No Map Symbol: PaC Drainage Class: Well Drained Field Observations Confirm Mapped Type: Yes No Taxonomy (Subgroup): Typic hapludults Profile Descri tion Depth (inches) Horizon Matrix Color Munsell Moist) Mottle Color Munsell Moist) Mottle Abundance/Contrast Texture, Concretions, Structure, etc. 0-12 10YR 6/6 Loam sand L Hydric Soil Indicators: Concretions Histosol High Organic Content in Surface Layer in Sandy Soils Histic Epipedon Organic Streaking in Sandy Soils Sulfidic Odor Listed on Local Hydric Soils List Aquic Moisture Regime Listed on National Hydric Soils List Reducing Conditions Gle ed or Low Chroma Colors Other (Explain in Remarks) Remarks: Hydric soil indicators were not observed. 11 - WETLAND DETERiINE[NATION rH drophytic Vegetation Present? Yes No Is the Sampling Point within the Wetland? Yes No tland Hydrology Present? Yes No dricSoils Present? Yes No Remarks: The wetland criteria were not present. The sampling point is not located within a wetland. Page 2 of 2 (Wetform)