Loading...
HomeMy WebLinkAboutNCG140456_COMPLETE FILE - HISTORICAL_20171026STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. DOC TYPE O. HISTORICAL FILE MONITORING REPORTS DOC DATE � o h / -7 ) a a G. YYYY M M D D Permit Number NCG140456 Central Files: APS _ SWP _ 10/25/2017 Permit Tracking Slip Program Category Status Project Type. NPDES SW In review New Project Permit Type Version Permit Classification Ready Mix Concrete StormwaterNVastewater Discharge COC COC Primary Reviewer Permit Contact Affiliation rick.riddle Coastal SWRuIe RECEIVED O C T 2 6 2017 Permitted Flow CENTRAL FILES Facility OWR SECTION Facility Name MajorlMinor Region Capital Ready Mix Concrete, LLC - Turkey Creek Minor Raleigh Location Address County 270 Moncure Pittsboro Rd Chatham Facility Contact Affiliation Moncure NC 27559 James Lochren 512 Three Sisters Rd Owner Knightdale NC 27545 Owner Name Owner Type Capital Ready Mix Concrete LLC Non -Government Owner Affiliation James Lochren 512 Three Sisters Rd Dates/Events Knightdale NC 27545 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 8/28/2017 Regulated Activities Requested /Received Events Concrete products manufacture RO staff report received 9128117 RO staff report requested 9122/17 Outfall 001 Waterbody Name Streamindex Number Current Class Subbasin Turkey Creek 16-38-4 WS-IV;NSW 03-06-04 Outfall 002 Waterbody Name Streamindex Number Current Class Subbasin Turkey Creek 16-38-4 WS-IV;NSW 03-06-04 Outfall 003 Waterbody Name Streamindex Number Current Class Subbasin Turkey Creek 16-38-4 WS-IV;NSW 03-06-04 Central Fifes: APS _ SWP 10/25/2017 Outfall 004 Waterbody Name Streamindex Number Current Class Subbasin Turkey Creek 16-38-4 WS-IV;NSW 03-06-04 Energy, Mineral & Land Resources ENVIRONM ENTAL QUALITY James Lochren Capital Ready Mix — Turkey Creek LLC 512 Three Sisters Road Knightdale, NC 27545 Dear Mr. Lochren: ROY COOPER Governor MICHAEL S. REGAN Secretary TRACY DAVIS RECEIVED Director October 26, 2017 CENTRAL FILES DWR SECTION Subject: General Permit No. NCG 140000 Capital Ready Mix Turkey Creek LLC COC NCG140456 Chatham County In accordance with your application for a discharge permit received on August 28, 2017, we are forwarding herewith the subject certificate of coverage to discharge under the subject state —NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143- 215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage (COC) is not transferable except after notice to the Division of Energy, Mineral, and Land Resources. The Division may require modification or revocation and reissuance of the certificate of coverage. Please note that NCG 140000 contains effluent limitations for process wastewater discharges (see Part IV, Section D). Wastewater discharges must meet the requirements of these effluent limitations. An exceedance of any of these limitations is a violation of permit conditions. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Energy, Mining, and Land Resources, or permits required by the Division of Water Resources, Coastal Area Management Act, or any other federal or local governmental permit that may be required. If you have any questions concerning this permit, please contact Richard Riddle at telephone number (919) 807-6375. Sincerely, v"L or Tracy E. Davis, P.E., CPM cc: Raleigh Regional Office Central Files Stormwater Permitting Program Files Nothing Cornpares--�, , SState of North Carolina I Environmental Quality I Energy, Mineral and Land Resources 512 N. Salisbury Street ! 1612 Mail Service Center I Raleigh, North Carolina 27699-1612 919 707 9200 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140456 STORMWATER and WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Capital Ready Mix Concrete is hereby authorized to discharge stormwater and process wastewater from a facility located at Capital Ready Mix Concrete -Turkey Creek LLC 270 Moncure Pittsboro Rd Pittsboro Chatham County to receiving waters designated as Turkey Creek, a class WS-IV, NSW water in the Cape Fear River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, and V of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective October 26, 2017. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day October 26, 2017. for Trac�E. Davis, P.E., Director /,"-- Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission _ t P.-vj; iI-", ro- O o • ' Capital Ready Mix Concrete �- 1(00 NCG 14045C N W E S Map Scale 1:24, 000 Capital Ready Mix Concrete Turkey Creek LLC Latitude: 350 42' 11" N Longitude: -790 10' 35" W County: Chatham Receiving Stream: Turkey Creek Stream Class: WS-N, NSW Index Number: 16-38-4 (Cape Fear Basin) Facility Location nCej q0 q G 2 r� NC®ENR Hcyrn, GaM— 0�,,fHT av E..— ..w .0 N.-- Rteawa[s Division of Energy, Mineral and Land Resources Land Quality Section National Pollutant Discharge Elimination System FOR AGENCY USE ONLY Date Received Y. N1on[h Qav Certificate ofCovera ge NICIGW41 W�A n Pcrtn [ Assi t L � � NCG 140000 NOTICE OF INTENT M v National Pollutant Discharge Elimination System application for coverage under General Permittm NCG140000: STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities classifies as: G) SIC (Standard Industrial Classification) Code: 3273 and like activities - Ready Mixed Concrete This NOI may be an application to discharge process wastewater. NCG140000 contains effluent limitations for process wastewater discharges. Wastewater discharges must meet the requirements of these effluent limitations. An exceedence of any of these limitations will result in a violation of the permit conditions. For questions, please contact the DEMLR Central Office or Regional Office in your area. (See page 6) (Please print or type) 1) Mailing address of ownerloperator (official address to which all permit correspondence will be mailed): (Please print or type all entries in this application form.) Legal Owner Name James Lochren (Please attach the most recent Annual Report to the NC Secretary of State showing the current legal name. Alternatively this permit can be given to an individual) Signee's Name (as signed for in question 29 below) Street Address 512 Three Sisters Road City Knightdale Telephone No. 919 999-0345 Alternate Contact Name Sara Lochren Alternate Contact Telephone (if different) 2) Location of facility producing discharge: Facility Name Facility Contact Street Address 70 rn 0 rn rn 0 State NC ZIP Code 27545 Email iim@capitalreadymixconcrete.com Email (if different) sara@ca italread mixconcrete.com Capital Ready Mix Concrete - Turkey Creek LLC Sara Lochren - General Manager 270 Moncure Pittshoro Rd. City Pittshoro State NC ZIP Code 27559 County Chatham County Telephone No. 919 999-0345 Fax: j 3) Physical location information: 35. ! Q q ff Please provide narrative directions to the facility (use street names, sttate road number`s, and distance and direction from a roadway intersection). Heading South on Highway 501 from the '1'own of Pittsboro, take a left hand turn on SR 1012 ,Moncure Pittshoro Road. The Property is located approximately 1,200ft down on the right. (A copy of a county map or USGS quad sheet with facility clearly located on the map is a required part of this application.) 4) Latitude 35°42'10,77"N Longitude 79°10'30.02" w (deg, min, sec) 5) This NPDES Permit Application applies to the following (check all that apply): I] New or Proposed Facility Date operation is to begin June 2018 ❑ Existing Facility Permit # Page 1 of 7 SWU-229-11032011 Last revised 712114 NCG140000 N.O.I. 6) Consultant's application information: Consultant: JD Freeman Consulting Firm: WithersRavenel Mailing Address: 115 MacKenan Drive City: Cary State: NC Zip Code: 27511 Phone: (919 ) 469-3340 Fax: {� Email: jfreeman@withersravenel.com (Optional) Staple Business Card Here: 7) Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility: SIC Code: 3 2 7 3 8) Provide a brief description of the types of industrial activities and products produced at this Facility: (Attach a site diagram showing the process areas present at this facility.) Concrete production will be the main site activity. Please see attached site plan that shows proposed plant location, sediment containers, truck wash station, settling basin, and discharge point. Stormwater Discharge, Wastewater Treatment & Discharge and Permitting Information 9) Discharge points I Receiving waters: Number of discharge points (ditches, pipes, channels, etc.) that convey stormwater and/or wastewater from the property: Stormwater-only: 4 Wastewater -only. 1 Wastewater Commingled with Stormwater., 0 For new facilities: Expected date of commencement of discharge: June 2018 What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater and/or wastewater discharges end up in? Turkey Creek - Stream index: 16-38-4 Receiving water classification(s), if known: WS-IV;NSW If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). N/A Will this facility discharge wastewater to SA (Shellfishing) waters? ❑ Yes I] No Note: Discharge of process wastewater to receiving waters classified as WS-11 to WS-V or SA must be approved by the N.C. Division of Water Resources, Public Water Supply Section. If DWR does not approve, coverage under NCG140000 cannot be granted. No new discharges of process wastewater are permitted in receiving waters classified as WS-1 or freshwater ORW. 10) Each applicant shall provide the following information (attach additional sheets as necessary): • Two (2) site plans depicting the facility or site with numbered outfalls which indicate stormwater and wastewater outfalls. The plans shall legibly show. at a minimum, (existing or proposed): o Outline of drainage areas with topographical lines and features o Stormwater/wastewater treatment structures o Location of numbered stormwater/wastewater outfalls (corresponding to which drainage areas) o Runoff conveyance structures o Areas and acreage where materials are stored o Impervious area acreages a Location(s) of streams and/or wetlands the site is draining to, and any applicable buffers o Site property lines, North Arrow, and bar scale Page 2 of 7 SWU-229-07122011 Last revised 7014 NCG140000 N.01 o If applicable, the 100-year floodplain line o Acreage of each stormwater and wastewater topographical area o Each of the facilities' wastewater or stormwater source and discharge structures and each of its hazardous waste treatment, storage, or disposal facilities o Site location (insert) Site plans shall be 24" x 36" in size. • Line drawing and description: A line drawing of the water flow through the facility. A pictorial description of the nature and amount of any sources of water and any collection and treatment measures. • A narrative description and identification of each type of process, operation, or production area which contributes wastewater to the effluent for each outfall, and a description of the treatment the wastewater receives (or will receive), including the ultimate disposal of any solid or fluid wastes other than by discharge. Processes, operations, or production areas may be described in general terms (e.g. "ash silo"). 11) Does the applicant have any unresolved Notice of Violations (NOVs)? © No ❑ Yes Wastewater. 12) What types of wastewater does your facility generate or discharge? Type of Authorized Wastewater Generate Discharge Sent to WW Treatment System Vehicle and equipment cleaning VE ❑ ❑ ❑ Wetting of raw material stockpiles (RM) ❑ ❑ ❑ Mixing drum cleaning MD ❑ M ❑ Further explanation, if necessary. Truck engine/grease wash downs will NOT be implimented on site. Wetting of aggregate piles will not take place. 13) Will your facility spray -down or actively wet aggregate piles? x❑ No ❑ Yes 14) Does the facility use any of the following on site? ❑ Phosphorus -containing Detergents ❑ Non -Phosphorus -containing Detergents ❑ Brighteners ❑ Other Cleaning Agents ❑ Other: 15) Are wastewater treatment facilities planned in the 100-year flood plain? ff] No ❑ Yes 16) Does your facility use or plan to use a recycle system, or recycle components in your treatment system? ❑ Yes 0 No If yes, what size storm event is the system designed to hold before overflowing? (for example, 1 D-yr, 24-hr) year, 24-hr rainfall event Page 3 of 7 SWU-229-07122011 Last revised 712I14 NCG140000 N.O.I. 17) Will your facility build a closed -loop recycle system that meets design requirements in 15A NCAC 02T f 1000 and hold your facilities' working volume'? ® Yes ❑ No Will your facility discharge wastewater to surface waters? ©Yes ❑No If the facility's treatment system meets the design requirements of 15A NCACO2T .1000 (including holding the 25-year, 24-hour storm plus one foot of freeboard), holds the working volume of your site, and does not discharge wastewater to surface waters, you may not be required to obtain an NPDES permit for wastewater discharges. If you believe this is the case, please contact DEMLR's Aquifer Protection Section Land Application Unit Central Office Supervisor or staff (1636 Mail Service Center, Raleigh, NC 27699-1636) for more information on obtaining the necessary permits or approvals. if you will discharge wastewater or stormwater to surface waters, please continue to apply for a permit to discharge associated with ready -mixed concrete or like operations under NCG140000. For further questions, please contact DEMLR's Stormwater Permitting Unit Staff, 18) A wastewater treatment alternatives review is required by 15A NCAC 2H.0105 (c)(2) for any new or expanding water pollution control facility's discharge in North Carolina. You may attach additional sheets. a) What wastewaters were considered for this alternatives review? ❑ VE ❑ RM 111 MD b) Connection to a Municipal or Regional Sewer Collection System: i) Are there existing sewer lines within a one -mile radius? ..................................... x❑ Yes ❑ No (1) If Yes, will the wastewater treatment plant (WWTP) accept the wastewater? .... El Yes ❑ No (a) If No, please attach a letter documenting that the WWTP will not accept the wastewater. (b) If Yes, is it feasible to connect to the WWTP? Why or why not?* It is not currently feasible to connect tut he WWTP in the Town of Pittsboro. The Town of Pittsboro has a VERY limited capacity in their exsiting WWTP and is not accepting a large amount of "Proposed Flow." The Town would consider accepting a small amount of flow but it would limit the production on site. c) Closed -loop Recycle System (must meet design requirements of 15A NCAC 2T .1000): i) Are you already proposing a closed -loop recycle system (CLRS)? ❑ Yes ® No (1) If Yes, contact DEMLR's Aquifer Protection Section's Land Application Unit (2) If No, is this option technologically feasible (possible)? Why or why not?* This option is technologically feasible and will be im limented as soon as financially feasible. Capital Ready Mix Concrete has been looking into multiple systems that would facilitate recylced water on their wash station. Plans are to add this CLRS in the next 2-5 years. (3) if No, is it feasible to build a CLRS on your site? Why or why not?* Yes, it is feasible and will be implimented in the future. There is enough room and the Engineer has considered spacing in site design. (4) What is the feasibility of building a CLRS compared to direct surface water discharge?* It is feasible to build a closed loop recycled system. The discharee point to surface waters will be used as a— back up or emergency system as well as the initial treatment method while the CLRS is being constructed. d) Surface or Subsurface Disposal System (e.g., spray irrigation): i) Is a surface or subsurface disposal technologically feasible (possible)? ...... .............. ❑ Yes ® No I See DWQ's Aquifer Protection Section Land Application Unit's Water Balance Calculation Policy for more information, on DWQ LAU's website htto://portal.ncdenrportal.ncdenr.org/webl�laps/tau/policies for more information. Page 4 of 7 5WU-220-07122011 Last revised 712114 NCG140000 N.O.I. Why or Why not? Subsurface leach fields are not feasible due to location and size contraints. Surface spray irrigation is not feasible due to lack of neccessity, cost and location. ii) Is a surface or subsurface disposal system feasible to implement?*.......... .............. El Yes M No Why or Why not? iii) What is the feasibility of employing a subsurface or surface discharge as compared to a direct discharge to surface waters?' The proposed settling basin in approximately 100 feet from the surface waters of Turkey Creek, just outside of the 100 year FEMA Floodplain and "Lone 2 Riparian Buffer on a steep slope. The surface irrigation or subsurface irrigation is not feasible due to extremely steep grade down to creek, location constraints, and cost to implement. e) Direct Discharge to Surface Waters: Is discharge to surface waters the most environmentally sound alternative of all reasonably cost-effective options of the wastewaters being considered?*... © Yes ❑ No i) if No, contact DEMLR's Land Application Unit to determine permitting requirements. f) If this review included all wastewater discharge types, would excluding some types (e.g. raw stockpile wetting) make any of the above non -discharge options feasible? ..............❑ Yes ® No You maybe asked to provide further information to support your answers to these questions after the initial review. Feasibility should take into account initial and recurring costs. Stormwater: 19) Does this facility employ any best management practices for Stormwater control? ❑ No I] Yes If yes, please briefly describe. Based on proposed increased impervious area (-2 acres) Capital Ready Mix Concrete is required to treat a drainage area of 1.70 acres. A 6,000 SF dry detention basin has been designed and will be implemented on the southern portion of the site. 20) Does this facility have a Stormwater Pollution Prevention Plan? 0 No ❑ Yes If yes, when was it implemented? 21) Are vehicle maintenance activities (VMA) occurring or planned at this facility? ❑ No I]Yes If yes, does your VMA area discharge into your wastewater treatment device? [K] No ❑ Yes Other/Permittinq: 22) Does this facility have a Division of Land Resources Erosion & Sedimentation Control (E&SC) Permit? 0 No ❑ Yes If yes, list the permit numbers for all current E&SC permits for this facility: 23) Is your facility subject to Phase II Post -Construction Area? ❑ Yes If yes, who is the permitting authority? ® No 24) Is your facility located in one of the 20 Coastal Counties? ❑ Yes ❑x No Is your facility adding more than 10,000 ftz of built -upon area or CAMA Major Permit? ❑ Yes 0 No Page 5 of 7 SWU-229-07122011 Last revised 7t2l14 NCG140000 N.O.I. 25) Is your facility discharging wastewater (treated or untreated) such as water from wetting of aggregate piles, drum rinse -out, or vehicle and equipment cleaning to a stormwater BMP? 0 No ❑ Yes If yes, please attach your approval from the permitting authority to do so. 26) Does this facility have any other NPDES permits? ® No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 27) Does this facility have any Non -Discharge permits (ex: recycle permits)? 0 No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 28) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? 0 No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? 0 No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? 0 No ❑ Yes d) Type(s) of waste: How is material stored: Sediment is stored in square open face containers Where is material stored: Please see attached exhibit "Proposed Material Storage Bins" How many disposal shipments per year: Name of transport 1 disposal vendor: Vendor address: Final Checklist This application will be returned as incomplete unless all of the following items have been included: 0 Check for $100 made payable to NCDENR. `t 0 This completed application and all supporting documentation. See Question 10. ❑x If an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR) or local designee: documentation verifying applicant has developed and submitted that Plan to the governing agency (required per 15A NCAC 02H .0138). l x❑ Two (2) site plans depicting the site plan with numbered outfalls which indicate stormwater and wastewater ti outfalls. See Question 10. 0 A county map or USGS quad sheet with location of facility clearly marked. 29) Signatory Requirements (per40 CFR 122.22) All applications, reports, or information submitted to the Director shall be signed and certified. a. All notices of intent to be covered under this General Permit shall be signed as follows: (S) For a corporation; by a responsible corporate officer. For the purpose of this permit, a responsible corporate officer means: (a) a president, secretary, treasurer or vice president of the corporation in charge of a principal business function, or any other person who performs similar policy or decision making functions for the corporation, or (b) the manager of one or more manufacturing production or operating facilities employing more than 250 persons or having gross annual sales or expenditures exceeding 25 million (in second quarter 1980 dollars), if authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. (2) For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or (3) For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. Page 6 of 7 5WU-229-07122011 Last revised 7/2114 NCG140000 N.O.I. Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article: or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article: or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the (Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars (S10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Sign Title: ,Owner - Capital Ready V of ArooliGA James Lochren crete At, 17 (Date Signed) Notice of Intent must be accompanied by a check or money order for $100.00 made payable to: NCDENR Mail the entire package to: Stormwater Permitting Unit Program Division of Energy, Mineral and Land Resources 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee the issuance of an NPDES permit. For questions, please contact the DEMLR Regional Office for your area. DEMLR Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ... (252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office ......... (919) 807-6300 Page 7 of 7 SWU-229-07122011 Last revised 7/2114 0 WithersRavenel 091 Our People. Your Success. August 21, 2017 NCDENR - Division of Energy, Mineral and Land Resources 217 West Jones Street Raleigh, NC 27603 RE: NPDES General Discharge Permit NCG140000 Narrative To Whom It May Concern: This is a brief narrative to identify and describe the site and operations for the production of ready mix concrete at the proposed concrete plant in the Town of Pittsboro. The proposed property is a 20.75-acre tract located at 270 Moncure Pittsboro Road in Pittsboro, North Carolina (PIN 9741-2071-9128). It is currently zoned as M2 Heavy Industrial. See attached Site Plan for vicinity reference and details. An approved Stormwater Discharge permit has been submitted to the Town of Pittsboro, and a Land Disturbance and Sedimentation & Erosion Control Plan is currently in review by Chatham County. This site was first developed in 1948, and much of the area was deemed to be impervious surface. It was determined by staff at WithersRavenel and the Town of Pittsboro that the site has a large portion of preexisting impervious area grandfathered in with no existing stormwater control measures. It shall be the owner's responsibility to treat any net increase of impervious surface area added to the site. From the site plan it was determined that there would be a net increase of 1.74 acres. The proposed solution is to treat all run off water coming from the area, shaded in light cyan, which is a total drainage area of 2.56 acres. This will be routed to the 6,000 SQFT dry basin in the southern portion of the site. Discharge routed through the pond is treated through a riser structure, level spreader & filter strip, and a high bypass outlet barrel before being discharged into Turkey Creek. The runoff is treated per State and Town requirements. Details can be found in the approved stormwater management plan held at the Town of Pittsboro or at Withers Rave neI's Cary office. Drainage from the rest of the site is routed into four outlet structure outfalIs, some of which were preexisting. The high point of the site is at the 386 contour at the northern most driveway, and the water lines on the site plan depict the flow's path to several catch basins that tie into the storm drainage system. The first outlet structure, labeled Outfall #1, is on the southwest corner of the site at the base of the proposed retaining wall. This outfall takes the sheet flow between the storage bins and the western retaining wall. Outfall #2 takes the flow from the shaded drainage area and is routed and treated in the stormwater control measure (SCM). Outfall #3 is located on the south facing retaining wall towards the eastern portion of the site. This outfall takes the drainage from the storage bin area as well as the center where the concrete plant is located. The last outfall, labeled Outfall #4, is located on the southeast corner of the sitejust behind the settling basin. This outfall takes the flow from the east section of the site, from the 368 contour over. The settling basin outfall, adjacent to the settling basin, is labeled" Proposed Discharge Point." Please see the attached details of the truck wash station, the two settling chambers, and the settling basin. The truck wash station is a three chamber system that forces the heavier aggregates and solids to settle out before reaching the final settling chamber, the stand pipe, and finally the discharge point. The two truck wash stations are 5 feet deep and are connected via a weir that allows water to pass from basin #1 to basin #2. Basin #2 is connected to the largest settle basin which has the FORTRANs unit treatment system. The permanent pool elevation of this basin is 362 with a depth of 3 feet. A 12-inch corrugated metal pipe is used as a stand pipe and serves as the inlet for clean, pH balanced, water which is discharged out through an 8-inch ductile iron pipe outfall. There is a proposed riprap apron and dissipater to mitigate any erosion or point flow coming from 115 MacKenan Drive I Cary, NC 27511 t: 919.469.33401 f: 919.467.6008 www.withersravenel.com I License No. C-0632 Cary I Greensboro Pittsboro I Raleigh I Wilmington ��.. WithersRavenet Our People. Your Success. the basin. T the monitoring station for the monthly and quartile tests is located here. Projections show that in the next few years Capital Ready Mix Concrete will be investing in a closed looped system and the basin will be used as their emergency back up only. Although it will not be immediately brought online, we have included the reuse station in the details. The sediment that is left in the main two chambers will be removed using a front-end loader and transported to a "drying bin" on the west side of the site. Once material has been dewatered and dried, it will be hauled off -site and disposed of accordingly. It is not projected that much sediment will reach the third, large settling basin, but this will be maintained and any solids removed on an as needed basis.,. The large settling basin is concrete in design and has a 6-inch curb that surrounds it. This curb will negate the ability of stormwater to flow into the basin and increase the volume of treated water. The intent of the proposed design is to ensure that all wash water and stormwater will be treated and discharged separately. The stormwater from the eastern portion of the site will be diverted around this basin and discharged from Outfall #4 as show on the attachment. If you have any questions, comments or concerns feel free to reach me via email at ifreeman(@withersravenel.com or at (919)469-3340 by phone. Sincerely WithersRavenel I man PE, LEEDAP Manager - Utilities Group N CA D. • Q SEAL r: Q34425Fik — ��v' A►Gl�fc • t;� i Page 2 of 2 B44016 MY sW e 13ox�1�6 Maf ),0 sW STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT N0. /v I� 0y6 1-0 DOC TYPE 4-1 HISTORICAL FILE MONITORING REPORTS DOC DATE I ❑ ') b I 7 1 0 a L YYYYMMDD Energy, Mineral & Land Resources ENVIRONMENTAL QUALITY James Lochren Capital Ready Mix — Turkey Creek LLC 512 Three Sisters Road Knightdale, NC 27545 Dear Mr. Lochren: ROY COOPER Governor MICHAEL S. REGAN Secretary TRACY DAVIS Director October 26, 2017 Subject: General Permit No. NCG140000 Capital Ready Mix Turkey Creek LLC COC NCG140456 Chatham County In accordance with your application for a discharge permit received on August 28, 2017, we are forwarding herewith the subject certificate of coverage to discharge under the subject state —NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143- 215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage (COC) is not transferable except after notice to the Division of Energy, Mineral, and Land Resources. The Division may require modification or revocation and reissuance of the certificate of coverage. Please note that NCG140000 contains effluent limitations for process wastewater discharges (see Part IV, Section D). Wastewater discharges must meet the requirements of these effluent limitations. An exceedance of any of these limitations is a violation ofpermit conditions. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Energy, Mining, and Land Resources.. or permits required by the Division of Water Resources, Coastal Area Management Act, or any other federal or local governmental permit that may be required. If you have any questions concerning this permit, please contact Richard Riddle at telephone number (919) 807-6375. Sincerely, O rtgi.tal diq*a 4 Rci -zd d. rRw&, &. for Tracy E. Davis, P.E., CPM cc: Raleigh Regional Office Central Files Stormwater Permitting Program Files Nothing Compares--.--- SState of North Carolina i Environmental Quality 1 Energy. Mineral and Land Resources 5I2 N. Salisbury Street 1 1612 Mail Service Center I Raleigh. North Carolina 27699-1612 919 707 9200 y7r s:AX Riddle, Rick L From: Valentine, Thad Sent: Wednesday, September 27, 2017 3:47 PM To: Riddle, Rick L Subject: Turkey Creek Comments Rick From looking at the drawings it appears that most of the site runoff, which includes the concrete loading silo area, flows toward the South to a proposed 6,000ft2 SCM (Stormwater Control Measure) and would be high in pH and acidity. They have a treatment unit for the 2,000ft2 settling basin on the East side of the facility but no type of treatment for that SCM on the South end of the project. I,would say they need another treatment unit at that SCM or provide a diversion berm or Swale to divert that flow to the settling pond. They would need to resize the pond and possible the treatment unit to account for the additional runoff. They should also have permanent diversions on each side of the SCM to divert runoff into the SCM, otherwise most of the runoff goes directly into Turkey creek with no settling. That last part may be more of an erosion control issue but you can weed out any comment that you feel aren't relevant. WT HERS & RAVENEL, INC 3193 ^� 115 MAGKENAN-OR CAR Y, NC 27511 66-tt2J531 Date —AY4^ o Pay To The ; . order of --I+�G�1.� - - I too,Jhq o t? ILI - - - — - Dollars wr Brun I For � �' - •�� ;ti -�x,� z��'�""�... :- xti �' .. _.r...' i. Y _t.-. .. .... - � �. _' MPnT 9E>t 17eY� GRAPHIC SCALE 0 100 200 1 inch s 200 ft. i •y a a I r r r CAPITAL CONCRETE USGS QUAD (2013) - PI I-ISBORO WithersRavenet MONCURE SITE Q Enginre�iP�anM"JSU.,,ey� PITI56 ft) CHATHAM QQk,r%TV NOR III CM.H. BO -4 126 mof �'1 s W L 717 Q0)(,# I �G Mof a�, sW