HomeMy WebLinkAbout20070295 Ver 6_8.08 Energy Dissipation Culvert 2_20191220HY-8 Energy Dissipation Report
External Energy Dissipator
Parameter
Value
Units
Select Culvert and Flow
Crossing
Crossing 2
Culvert
Culvert 2
Flow
240.30
cfs
Culvert Data
Culvert Width (including multiple
barrels)
7.0
ft
Culvert Height
7.0
ft
Outlet Depth
3.57
ft
Outlet Velocity
10.39
ft/s
Froude Number
0.97
Tailwater Depth
3.57
ft
Tailwater Velocity
5.59
ft/s
Tailwater Slope (SO)
0.0134
External Dissipator Data
External Dissipator Category
Streambed Level Structures
External Dissipator Type
Riprap Basin
Restrictions
Froude Number
<3
Input Data
Condition to be used to Compute
Basin Outlet Velocity
Best Fit Curve
D50 of the Riprap Mixture
Note:
Minimum HS/D50 = 2 is Obtained if
D50 = 0.350 ft
D50 of the Riprap Mixture
1.167
ft
DMax of the Riprap Mixture
1.917
ft
Results
Brink Depth
3.812
ft
Brink Velocity
11.222
ft/s
Depth (YE)
3.400
ft
Riprap Thickness
2.876
ft
Riprap Foreslope
3.8340
ft
Check HS/D50
Note:
OK if HS/D50 > 2.0
HS/D50
0.000
HS/D50 Check
HS/D50 is NOT OK
Check D50/YE
Note:
OK if 0.1 < D50/YE < 0.7
Check D50/YE
0.343
D50/YE Check
D50NE is OK
Basin Length (LB)
28.000
ft
Basin Width
25.667
ft
Apron Length
7.000
ft
Pool Length
21.000
ft
Pool Depth (HS)
0.000
ft
TW/YE
1.050
Tailwater Depth TW
3.570
ft
Average Velocity with TW
2.052
ft/s
Critical Depth (Yc)
1.347
ft
Average Velocity with Yc
6.291
ft/s
Downstream Riprap for High TW
Distance: 1 LB
Velocity
8.985
ft/s
Size
0.526
ft
Distance: 2 LB
Velocity
6.119
ft/s
Size
0.244
ft
Distance: 3 LB
Velocity
4.068
ft/s
Size
0.108
ft
Distance: 4 LB
Velocity
3.044
ft/s
Size
0.060
ft