HomeMy WebLinkAbout20070295 Ver 6_8.06 Energy Dissipation Culvert 1_20191220HY-8 Energy Dissipation Report
External Energy Dissipator
Parameter
Value
Units
Select Culvert and Flow
Crossing
Crossing 1
Culvert
Culvert 1
Flow
59.25
cfs
Culvert Data
Culvert Width (including multiple
barrels)
4.0
ft
Culvert Height
4.0
ft
Outlet Depth
2.10
ft
Outlet Velocity
7.47
ft/s
Froude Number
0.91
Tailwater Depth
2.10
ft
Tailwater Velocity
5.65
ft/s
Tailwater Slope (SO)
0.0285
External Dissipator Data
External Dissipator Category
Streambed Level Structures
External Dissipator Type
Riprap Basin
Restrictions
Froude Number
<3
Input Data
Condition to be used to Compute
Basin Outlet Velocity
Best Fit Curve
D50 of the Riprap Mixture
Note:
Minimum HS/D50 = 2 is Obtained if
D50 = 0.193 ft
D50 of the Riprap Mixture
1.167
ft
DMax of the Riprap Mixture
1.917
ft
Results
Brink Depth
2.216
ft
Brink Velocity
8.300
ft/s
Depth (YE)
1.992
ft
Riprap Thickness
2.876
ft
Riprap Foreslope
3.8340
ft
Check HS/D50
Note:
OK if HS/D50 > 2.0
HS/D50
0.000
HS/D50 Check
HS/D50 is NOT OK
Check D50/YE
Note:
OK if 0.1 < D50/YE < 0.7
Check D50/YE
0.586
D50/YE Check
D50NE is OK
Basin Length (LB)
16.000
ft
Basin Width
14.667
ft
Apron Length
4.000
ft
Pool Length
12.000
ft
Pool Depth (HS)
0.000
ft
TW/YE
1.055
Tailwater Depth TW
2.101
ft
Average Velocity with TW
1.495
ft/s
Critical Depth (Yc)
0.769
ft
Average Velocity with Yc
4.752
ft/s
Downstream Riprap for High TW
Distance: 1 LB
Velocity
6.497
ft/s
Size
0.275
ft
Distance: 2 LB
Velocity
4.508
ft/s
Size
0.132
ft
Distance: 3 LB
Velocity
2.996
ft/s
Size
0.059
ft
Distance: 4 LB
Velocity
2.243
ft/s
Size
0.033
ft