HomeMy WebLinkAbout19990902 Ver 1_COMPLETE FILE_19990819MEMORANDUM TO: John Dorney Regional Contact: Brad Shaver Non-Discharge Branch WO Supervisor: Jim Mulligan Date: SUBJECT: WETLAND STAFF REPORT AND RECOMMENDATIONS Facility Name US Coast Guard Sewage Pumps County Pasquotank Project Number 99 0902 County2 Recvd From DCM Region Washington Received Date 8/9/99 Recvd By Region 9/9/99 Project Type emergency generator Certificates Stream Stream Impacts (ft.) Permit Wetland Wetland Wetland Stream Class Acres Feet Vii= Type Type Impact Score Index Prim. Supp. Basin Req. Req. ?- O Y O N ? 30-34-7 sc 30,150. F ?- Mitigation Wetland MitigationType Type Acres Feet Is Wetland Rating Sheet Attached? O Y *N Did you request more info? O Y p N Have Project Changes/Conditions Been Discussed With Applicant? O Y 4 N Is Mitigation required? O Y O N Recommendation: OQ Issue O Issue/fond O Deny Provided by Region: Latitude (ddmmss) Longitude (ddmmss) Comments: This pro*ect does not involve any wetland acreage- This project wants the Divisions opinion on a diesel fuel tank for hack-up power to service a wastewater pip station. The tank is a 2,50 gallon tank with internal secondary containment, cc: Regional Office Central Office Page Number 1 Facility Name US Coast Guard Sewage Pumps County Pasquotank Project Number 99 0902 Regional Contact: Brad Shaver Date: Comments (continued from page 1): cc: Regional Office Central Office Page Number 2 f USCG Support Center Elizabeth City, NC New Emergency Generator and Fuel Storage Tank Sewage Lift Station Building # 29 (C(DPY L U.S. Department of Transportation United States Coast Guard s Commanding Officer Support Center U.S. Coast Guard Elizabeth City, NC 27909-5006 5535 Mr. Steve Benton NCDENR, Division of Coastal Management P.O. Box 27687 77 Raleigh, NC 27611-7687 JUL 2 2 1998 Dear Mr. Benton: Please accept this letter as an official request for consistency determination on the enclosed project. This project falls within the Areas of Environmental Concern (AECs) for Pasquotank County, North Carolina. The proposed project would install a generator with a 250 gallon diesel fuel tank to provide emergency electrical power to sewage lift pumps located in Building 29. This building is the main collection point for all wastewater generated on the facility. Wastewater collected at Building 29 is pumped to the City of Elizabeth City Publically-Owned Treatment Works under an locally issued wastewater permit. Presently, storage capacity at Building 29 is approximately 2 hours during peak flow periods and 5 hours during off-peak times. Infiltration from heavy rains greatly affects wastewater storage capacity. The proximity of Building 29 to the Pasquotank River and. the threat of overflow during an extended power outage provides emphasis to the importance of this project. Coast Guard Support Center Elizabeth City is a federal facility and is exempt from all CAMA permit requirements under NCAC Title 15, Chapter 7, Section .0402. If you have questions concerning this request, please contact CDR Mike Herring at (252) 335- 6356. Sincerely, r R Captain, U. S. Coast Guard Copy: w/o enclosure CDR M.E. Herring, SCEC CDR M. Valerio, SCEC ■ rag -nt sir C6 ':?z:. 4 ?_ "'? N .r: "' '. Ivry. ?. . ?.. _ , ? a, pc.: ? 1 S;? ? ?' .:A1T ??"? ilCOl9B5??'?1? W z 3 L 1 4) O C) Cl) m Cn LLJ m x c F- 3 L6 m z 0 w 0 ?aP U• ?r • m` o 0 0 op . o + m • O fip? . ` ?M O w m V c W C W C W 0 O Q Q. ? N N N !o L: C ccul = O www m CL W N ._ CL m . N Z U) L: m o .>_ L V V - Q V Cl) rML C? N y W O w m i N m V c W to a D i Y ? I L F = 0 ova N 4 N O N z 0 V! N a# E a E L 9 ame ?m a? 'O W rg N T- O O co 0 0 0 O tD O O O -? --, - -- -- W0396%22 P.11 r Dlsgover the Advantages 1 of Hoover Vault Tanks: - UL 2085 Protected Secondary Containment Listed ! 2 hour fire rating using lightwei ht concret j • Two-hour fire rating reduces distance requirements g e True 360° "pressure testable" sCCAndary containment i under all national fire codes • Vehicle Impact Protection • Lightweight tank design minimizes freight charges and foundation construction • Ballistiic protection Mounted on 2" supports for complete visual _ _ • Built-in leak detection tube inspection • Meets requirements of all National Fire Codes 30 year warranty UPC Articles 52 and 79, A '• ppendix II F and • Fiberglass clad exterior - 30 year maintenance free Standard A-11-F- l warranty NFPA Standards 30 and 30A BOLA i • Factory Installed Equipment Packages: SSCCE Motor fuel dispensing. emergency generator/Fuel oil • CARB'Certified for Stage I and. LI Vap(r Recovery . used oil collection (Others available upon request.) • Underwriters Labordtcnies of Canada (ULC) Listed Tank capacities from 2,50 to 20,000 gallons VAULT TANK Pitched Roor EPoxy Exterior Coating fOPIIONAL: Fberglass? bidding} SECTION ,r-- Inner Steel Tank J--• tight Weight Insulating Concrete Second Steel Tank (Pressure Testable) /- Supports with Anchoring Holes PROTECTED SECONDI U.L Standard 2085-INSULATED SECONDARY FOR FLAMMABLE UQU1L CONTAINMENT MATNMENT ABOVEGROUND TANKS PROTE TYPES r D--p- ndabl- Envit- if ycxt arc concerned about the impact fuel storage has on your hfotwrn livw.1owk at the aboveground advantages of Hoover C.'onkrinmeni. tictover tanker provide safe, aria-dabic solutions for the storageof ycmr.ttammable and combustible liquids. Hoover Vault Tanks meet all national fire code rcquircments for "fire rated" nbovegmund storage tanks. Vault Tanks are labOod according to Underwriters Laboratories 2085 "Protected Secondary Contain- mcnt" for aboveground storage tanks containing flamnwble liquids. m Mal Pr "I=?cti n Hoover Vault Tanks and FiberVaults are currently being used for the °. storage and dispcusltng of gasoline and diesel fuel and the collection of used oil and wasto solvents in a variety of locations. Including: * MotorPivils * Flight Lines * Mainlommcc Shops * golf Courses * Fire/Rmme Operations i * Air Buses * Shipyards Vwd! Tank Hoover Pauli Tbakr tuilm a pareMeK UL Listcd, &mbkwall teak design with "Ughtwelght iaantasiaa ntaterW surn'rusg!Eing tlx: imur tank. A -pressure us *W sacw l steel tank sus wards the insulst ing amerid. providks to tlic material and wcondary leak contdmnx t for the pewwa tsar L A leak detccxion tube, hotailed in the Utsuie ttg material. has boat M=W and listod by UL to allow detection of loaking fluids from the toner tank. FiberVault ? Radar Sites * Standby Power Generation Marine Fueling i * Grounds Maintenance * Research Laboratories Hospitals { * Oil Heating Systems * RecyctinglReutilization Desalts GSA Cust miews under Contract Number 05-07F-91146 Indude: * Mllltar'y - All Branches * National Guard x Coast Guard Fish & Wildlife Service * Departroent of Agriculture * Forost Service * Federal Aviation Administration * National Park Service * Postal Service if your facility is exposed to corrosive cnvironments. such as salt water spray. Hoover has your solution - Fibervauft. FiborVault istant fiberglass cladding around all sides of provides a UV i !es Hoover Vault Tnnk&. The cladding protects the outer steel tank and is resistant to crac?kiag due to cold temperatures. FiberVautt has a "Maintenance Free Exterior Warranty". Hoover Containment, Inc. Is the largest national manufacturer of rectangular aboveground storage tanks. Hoover provides fire rated and non-fire rated tanks from eight, regionally located manufacturing facilities. These facilities allow Hoover to provide quality products to companies concerned with implementing national tank replacement programs. Hoover tatnks are built to aevornmodate your aboveground liquid storage needs. In addition to the standard doublewall fire rated construction, we offer: - * Factory Installed Equipment Packages for: Fuel, ]Dispensing, Standby Generators, Used pit, Steps and Platforms, etc- * 'Dank Capadtles 750 to 20,040 Gallons * Internal coatings compatible with aviation fuels and deicing fluids * Dual compartments available in all capacities ,JUN-17-1998 11:46 7703968622 P.02 STANDARD PORT ARRANGEMENT Secondary 1$" Manhole Containment (Tanks 5,000i. gallons .?- ".l Working Vent r) Primary 'funk 1 m .- Crgency Vent and W* Pharr 1 ® Suction Pump .'= a.. '•r Vapor Recovery i (spare.) ?; ;.•.; Ida" '" 'r:vs i Seconds „ 3;'s Optional: IS gait. Secondary i. ;.... Spt11 C onlainmenl Containment I':. /Lc?ck:iblc 1_itl ?„..'.. f F.merg enCy vent :.: ik? a AdapLeT& b "; 'i Cap, nr Submersible Sr . , 1/2" uin w/Threaded O Brass "T" Plu o Pump Nipple g (spare) FidI _ O i r. Monitoring Pipe Le !?•'t- Suction Pump tit t7 u..:i Mechanical O p p (share) ?-?a=.:?;.• Level Gauge 0 (9 Fire-Rated Material Fill._ Electronic (as required) Level Gauge Primary Tank Standby Working Vent Iiuel (spare) F TC'¢F vrEw ADDMONAL Fl'rMCS 7h ; =.;r 5, AVATT,ABIX L'I'ON REQUES'T' :vit'T•-S,:P..?.""•.? :,, ? ?°aix" s' "'S.afri : : ^ 3' i?? Si4?t'! •r. :?Ty, ?ri:?7:x::'?? r:: .aF?"; i'?! ? i 7! .•'X.+???'.I?-:'?: sY '`g'?i'i?x'.- ' .'L .?; ? ?,. .. a>T , i Y' 3 k ^ ? F _ rya.,: •: xa..«.. 'l .:,a.,+? ? I??, '? ? ?•?, ?.?.">', `?' ?'••? (I' a`?t?l..t•,,w.: _'r'aa., ? ? ? . i -a;?x???,z3; •+ a •..•'- r r? ? i?.?i'.;:`: i, f3 C. y S'tar>adar+d nO ' a Contawni wnt '7i NEL3? ; b• i:=r3'Wr .o>k.s'L•i_f•t'?': 's t Y! t(i" Vau? Tank - ,# ?,'?i.'.d- ++':'?`r 'Y.l'3??i','"i;;•p'S'.. ?.,r.::,: TANK ONMRIWL DIMENSIONS t, { I: 1 1 r i s. F1 x VP x H ;i rr-r •z CAPACtTS' WtstGIST !as3•y,ur1.'? i JR. M?rtrM,`r ;C 254 4'9" x 3'7"x 3'9" 3300#: 500. 6'8" x 4:'7"x 3'9" 5.OW# ' 1,000 79' x 5'7"x 4'9" 7,500# • I ,500 I 0'7' x S' H .l Nx 4'9" _ 1 {1,{ }( i;7 :; • ' e?', 7:.?' • , , ref'?` • h" 43. er `:r .?'4•-•9"?e r• f, 2,000. l 1.1f1" x b11 '_x 49' 12.5(X)# K)# ? ?•?? tr? ,, y s 2,50 9'5' x ftl I"x 7'1 13.800#f 3,000 9'8" x T'11 x 71" 15.8Q0# • ,dal ' '_? .;:. fiza? ?, •i.', :• ? ,.,• y ,()E10 12'8" x !'I Ih 7'1'v 19,400#i~ .41 1.6 5.000 1$'S' x 7'1 I'x 7'1' 23'Ot ...t ks :' ; ` . ? • :::? ';; ? yyn • ?' , 8,000 18 8' x 711 x 7,1 2fi,7(X)!# ..:q ; I` • e?,%.. i Pr Ax 8,000 24'9' x 9' 11 "x 7'l " 34,(xx)#F 10.000 30'8' x t'l 1"x 7'I" 4E,3{x 12,000 36'8" x 11". 7`1 48,200# 15.000 45°8" x ?'i I"x 7'I" 59-'500# yt y' 20 000. 60'8" x?' I I "x 7'l " 75 00(1f1 s v ?.-r,.•Y w "ZIA ,:7'+'=.-v:.c? . ': S' .@•' ` of < r ?,3s n s ? 1 K : '* ?4Y 1?4J _ :y L:"J! )4?. •5 '?lY.? De.?^3'' .rr7ar; .. ? .Pr +S ..•S;ct <N•+? a.c i^'if' ? '?' ??.s ,?Y~>3. r. !• S„`C? < " fi,'7.Ti:. it.? xR' ? t fay ??ytt.??t???,??..??, ? }`' . N ' ? ?' ???.}.??..F 'i tY '? •?. 1 ':5?f ?l'C•,it'.! , .. • ?(i'lii3 ` ?. 7.7? .?, ? ? s S.'? L;y '?t x ?f'`; J..? TOTAL P.02 7 s Q? • r Nil N ' 90'd ?9896?0LL ' a M ..- Ism 1114 i 1 lei I t I p t Rid 9M em ?. JUN-17-i999 11:33 7703968622 P.04 ssLECT:E g MOVMR IIL o The complete Hoover vault tank assembly including fire barrier is manufactured, tested, 'and labeled per Underwriters Laboratories UL 2085 BZCONDARILY coHTAIRp PRp =CTSO TYPE vault tank standard t provide built-in secondary containment, two ho1ar fire resistance, ballistic prote tios't,. and Vehicle impact resistance required by.fire codes for the safe storage of flammable/combustible lisauids, o The hoover vault inner and outer tanks are built, tested, and labeled per Underwriters Laboratories DL-142, ag part of the UL-2065 listing, for quality .assurance and structural integrity. E ch tank is pressure-tested prior to shipment. o Hoover vault tanks include an outer ¢?eel jacket which is UL- e t s-ahlp to ensure true 360 degree secondary containment of the primary inner tank. Alternate exposed concrete designs are generally not UL-listed for secondary containment since they rely on a lastie membrane around the inner tank for secondary containment. The Hoover outer steel jacket also protects the fire barrier fr'a weathering, cracking, spalling, or shrinking that can occur with exposed concrete designs . 0 Hoover vault i*+**e tank is constructed of minimum 3/2.6" thick steel with continuous welds on all sides, inside as well s outside. Extra steel thickness maximizes resistance to pinpoint corrosion f m bacteria build-up in stored petroleum products. i 0 309ver vault tanks utilize a special lightweight material as the internal fire barrier, res=lting in a 25W lower wei?ht compared to exposed concrete dessigns;.- a Lois-pratile rectasagular c3esif9a uini aes need for stairs to access fill box and diapesa s=r on tog of tasnsk. freer-flat top design provides safe, stable personnel platforw for routine tank n=itoringland maintenance. Safer and easier to access th4n cylimdrical taTeks. o Ali Hoover vault to kc include st leak detector tube to enable monitoring betweea the i=aer primary tank and otter secondary containment tank. The UL-2095 s Y CO , listing provides assurance that the fire resistive luring will not hinder the tection of leaks. 0 optional fiberglass exterior clad - -i (Fibervault) provides guaranteed thirty year sssalntenance free exterior and additional protection from harsh environmental caisdi bons . o xoever vault tanks include standard at no additional cost. o Hoover carries comprehensive liabilitiy insurance of $11 million to ensure future cult-w r support (copy of insurance a rtifieate available upon request). o Hoover vault tanks meet requirementsFof NFPA Sections 30 and 30A for aboveground storage tanks, as well as the uniform Fire Code Articles 52, 79, Appendix IIP;.._ SttnAArd A-11-P-1. o Hoover vault tanks can be grounded in accordance with NFPA-780. - - o All steel tank openings are NM three ed, including leak detector tube. 1 i r _ 7703968622 P.05 ?, ;(;ROU= The safe aboveground storage of fuel and other flammable Ii such as Uniform Fire Code (UPC) Articles 52, 79, guide is regulated by fire cot Appendix IIF, Standard A-11-F-1 and t National : Fire Protection Association (NFPA Section 30 and 30A.. These codes inclu stringent performance requirements to ensure a tank design includes proper seconda containment, two hour fire resistance, ballie is protection, and vehicle impact reaistanc How can ;a customer determine if a part cular tank design requirements? Fortunately, Underwriters L rata meets these tough. t ry (UL) has developed a test standard f aboveground storage tanks caller! M-2085 88 NDARILY C'ONT AII4SD, ..P1iOT8CTBa TYPE. If a to design iii submitted to UL and passes the stri6t series of tests required by the fire code UL authorizes the tank manufacturer to plac? a UL-2085 SZCO=A3tILY COHTA33MD, PROTECT. TYPE label on each tank built using the apiiroved design. re lato ? c purchasing Thus, a customer can achis• 9u x}' ompliance with the fire codes by a tank with a UL-2085 lSBMIMARI. G0?iTATl?SI1, PROTSCTED TYPE label, such as t Zee manufactured by Hoover Group under G; Contract #QS-07F-9114G. An earlier UL test standard, UL-2085 X=VLATRD, FrAn RSSZSTJU TYPE, doffs not meet all the new fire code quirements. Additionally, many common fit protected tank models are not lasted for se ondary containment. Therefore, the custom( must be sure which UL label will be provided by the manufacturer. State of North Carolina Department of Environment, Health and Natural Resources Division of Coastal Management James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Donna D. Moffitt, Director Mr. John R. Dorney NC DENR Division of Water Quality P.O. Box 27687 Raleigh, NC 27611 REFERENCE: CD99-11 Applicant/Sponsor: U.S. Coast Building 29 Emergency Generator Dear Mr. Dorney: 07/27/99 V K., County: Pasquotank Guard for Sewage Pumps The attached Consistency Determination, dated 07122199 describing a proposed Federal Activity is being circulated to State agencies for comments concerning the proposal's consistency with the North Carolina Coastal Management Program. Please indicate your viewpoint on the proposal and return this form to me before 08117199 Si Ven r ? Stenton Con sistency Coordinator REPLY This office objects to the project as proposed. Comments on this project are attached. This office supports the project proposal. No comment. Signed Date QEHNR P.O. Box 27687, Raleigh, North Carolina 2761 1-7687 Telephone 919-733-2293 An Equal Opportunity Affirmative Action Employer 50% Recycled / 10% Post-consumer Paper USCG Support Center Elizabeth City, NC New Emergency Generator and Fuel Storage Tank Sewage Lift Station Building # 29 COPY o L t i U. S. Department of Transportation United States _ Coast Guard /J1 Commanding Officer Support Center U.S. Coast Guard Elizabeth City, NC 27909-5006 5535 Mr. Steve Benton NCDENR, Division of Coastal Management P.O. Box 27687 Raleigh, NC 27611-7687 Dear Mr. Benton: JUL 2 2 1998 Please accept this letter as an official request for consistency determination on the enclosed project. This project falls within the Areas of Environmental Concern (AECs) for Pasquotank County, North Carolina. `1 The proposed project would install a generator with a 250 gallon diesel fuel tank to provide emergency electrical power to sewage lift pumps located in Building 29. This building is the main collection point for all wastewater generated on the facility. Wastewater collected at Building 29 is pumped to the City of Elizabeth City Publically-Owned Treatment Works under an locally issued wastewater permit. Presently, storage capacity at Building 29 is approximately 2 hours during peak flow periods and 5 hours during off-peak times. Infiltration from heavy rains greatly affects wastewater storage capacity. The proximity of Building 29 to the Pasquotank River and. the threat of overflow during an extended power outage provides emphasis to the importance of this project. Coast Guard Support Center Elizabeth City is a federal facility and is exempt from all CAMA permit requirements under NCAC Title 15, Chapter 7, Section.0402. If you have questions concerning this request, please contact CDR Mike Herring at (252) 335- 6356. Sincerely, R Captain, U.S. Coast Guard Copy: w/o enclosure CDR M.E. Herring, SCEC CDR M. Valerio, SCEC s i ?t W z C/) 3 L _4) Z V 0 C3 C O.Jc 4w 4) CO m C? N Cl) LU x c W 3 m z C ff llepn U•. i L ? c w 9 d • 44 4 . f, m o t w •« m .? t3 w c W C O Q. Q. c?NyN C 0 o > ZL7 w z L V Z V Q V v/ C? N as c 0 0 CL Q. N ? _ N N N 3 'a L: > ;o? mm? m 0 O C 7 dl m IL E? V W of V C O O i F C 0 cr) OW CV N D ? C O w W IL E C 9 W ? a m 19 C W 4) N r O O co 0 0 0 0 co 0 0 0 ?. i --, --, .. -, ? no37bCbi_'? P. 11 I Dlsgover the Advantages of Hoover Vault Tanks: 1 • UL 2085 Protected Secondary Containment Listed ! • Two-hour fire rating reduces distance requirements 2 hour fire rating using lightweight concrete under all national fire codes True 360° "pressure testable" secondary containment i • Lightweight tank design minimizes freight charges • Vehicle Impact Protection and foundation construction • Ballistri protection • Built-in' leak detection tube • Meets requirements of all National Fire Codes UFC Articles 52 and 79, Appendix II F and Standard A-11-17- I NFPA Standards 30 and 30A BOCA SECCI • CARB'Certified for Stage I and If Vapor Recovery • Underwri ters Labordtories of Canada (ULC) Listed • Mounted on 2" supports for complete visual inspection • 30 year warranty • Fiberglass clad exterior - 30 year maintenance free warranty • Factory Installed Equipment Packages: Motor fuel dispensing. emergency generator/fuel oil, used oil collection (Others available upon request.) • Tank capacities from 2,50 to 20,00(} gallons VAULT TANK CRASS SECTION Pitched Root r-1 1 Inner Steel Tank i Light Weight Ppoxy Exterior Coating Insulating Concrete (OMONAL: Fiberglass dwidmg) Second Steel Tank (Pressure 't'estable) Supports with Anchoring Holes PROTECTED SECOND Y CONTADWMfENT U.L. Standard 2085-INSULATED SECONDARY ONTATNUENT ABOVEGROUND TANKS FOR FLAMMABLE UQU S. PRMCIEU TYPES r' J U1Y-1 f _.L:= 11 - J r ndabl- Envir Om_-ntal P ti ° qm If you = concerned about the impact fuel storage has on your boom line, look at the aboveground advantages of Hoover - Gontainmext. Hcovee woka provide safe, affordable solutions for the storage of your.tlammabio and combustible liquids. Hoover Vault 'B'anks meet all national fi code rcquircracots for "fire rand" aboveground storage tanks. Vault Tanks are labeled according to Underwriters Laboratories 2085 "Protected Secondary Contain- awnt" for aboveground storage tanks containing flammable liquids- Hoover Vault Tanks and FiberVaults are currently being used Yoe the storage and dispensing of gasoline and diesel fuel and the collection of used oil and wasto solvents in a variety of locations, Including: 1 * MotorPlxils f * Flight Lines * Maimena uc Shops * Golf Courses * FirctRewue Operations * Air Bases Vein! 'drink No-or vault 74nkr utilize a panted, UL Listed, tkmblewall tank design wkh "I4hrweigttr" inw Wag, rnaweiw surrounding tbo inner tank. A "pres4rre Neste seeawW Acd tank surrounds the insulat- ing material. pmvidmg p to alai matcaal toad sccandary leak Containment for the prim my triode- A leak detection tube. installed in the insulating matmial, has been um and and listed by UL to allow datecuon of leaking fluids from the inner tank. Flbervault if your facility is exposed to corrosive environments, such as salt water spray, Hoover has your solution - isi°berVaa t. FburVault provides a UV iesinant fiberglass cladding around all sides of Hoover Vault Tanks. The cladding protects the outer steel tank and is resistant to cras dng due to cold temperatures. FiberVault has a "Maintenance Free Fxteriorwarrunty". Hoover Contafnmen4 Inc. Is the largest national manufacturer of rectangular aboveground storage tanks. Hoover provides fire rated and non-fire rated tanks from eight, regionally located manufacturing facilities. These facilities allow Hoover to provide quality products to companies concerned with implementing national tank replacement programs. Hoover tanks are built to am.ommodate your aboveground liquid storage needs. In addition to the standard doublewall fire rated construction, we offer: a Factory Installed Equipment Packages for: Fuel Dispensing, Standby Generators, Used 011, Steps and Platforms, etc. * rank Capacities 250 to 20,000 Gallons * Internal coatings compattMe with aviation fuels and deicing fluids * Dual compartments available in all capacities * Shipyards * Radar Sites * Standby Power Generation Marine Fueling " Grounds Maintenance * Research Laboratories Hospitals * Oil Heating Systems Reaycling/Reutili7ation Depots GSA Cusiomers under Contract Number GS-07F-9114G Include: * Military -All Branches * National Guard * Coast Guard * Fish & Wildlife Service * Department of Agriculture * Forest Service * Federal Aviation Administration * National Park Service * Postal Service 0 JU]1-1 l-t77th 11%4b STANDARD PORT ARRANGEMENT Sccondary l $" ManhVlz Containment (Tanks 5,000 gallons Working Vent and lar*r) Pharr 1 Vapor Recovery ® i Optional: 15 gal, Spill C.ontainmcnt O wulck-able Lici, Cap, Adapter & o i 1 /2" Drai n wn hreaded /1 r Brass "T" Plug LJ l Fill o Monitoring Pipe Mechanical 0 O 0 Level Gauge j Electronic -? - Level Gauge Primary Tank Working Vent TdP VLEW Primary 'rank Emergency Vent Suction Pump ® (space) Secondary Containment Emergency Vent Submersible Pump Nipple (spare) Suction Pump (spare) Fire-Rated Material Fill ¦ Standby (as required) Duel (span;) ADDMONAL FITTINGS AVAILABLE UPON REQUFST Standard Daulle Containment Vau Tank TANK OYE1tALiL j)DZ VSIONS CAPACITY 0 x W x H WEIGH' 0 255 V9* x 3'7"x 3'9" 0 # .9.20 / 500 6'8" x 4:'7"x Y9, ?/ ?? (, 51000# 1,000 7'c3" x 5'7"x 4'9" 7,500# 1,500 10'r x S' I I "x 4'9" l (),CXM 2,000 11'[ CY' x 611 'x 4'9' 12.5(X)# 2,500 9'5" x 1 I"x 7'1" 13.800# 3,(X10 9'8° x I -x 71" 151800# 4,000 12'8" x !'I I "x 711A' 19,400# 5,000 15'8" x 7'11 "x 7" 1 " 23,000# 61000 18'8" x 7' 1 l "x 7' I" 2fi,7(1()## 8,000 24'8" x it "x 7' 1" 34,(XX) # 10.000 30'8" x I I"x 7'1" 41,3(X)## 12,000 36'8" x 1 I 'x 7'1 " 48,200# 15.000 45'8" x ,7'11"x 71" 59,500# 20,000 60'8" x ' 'I I "x 71 " 75,000# 7703968622 P.02 P.02 1 rY Y I K WA Q?? 11NNNNNN il{ r m O an es ?PII ? E ii 3 a 90'd ZZ9896£0LL a i to af? s 3 A ---?-?-+? t N w Le . 'r _I pill Ell f lag i f b£:TT 866T-LT-Nnr JUN-17-1998 11:33 SELECTION OF • HQOVBR VAULT TAM o The complete Hoover vault tank asses teited,'and labeled per Underwriters PR;;CTED TYPE vault tank standard tC hoiir fire resistance, ballistic protel byfire codes for the safe storage of 77039GBG22 P.04 Sly including fire barrier is manufactured, Laboratories UL 2095 9ZCONDARILY coNTAI1r=, provide built-in secondary containment, two :ion, and vehicle impact resistance required flammable/combustible liquids. o The Hoover vault inner and outer hanks are built, tested, and labeled per Underwriters Laboratories UL-142, al part of the UL-2085 listing, for quality assurance and structural integrity. E ch tank is pressure-tested prior to shipment, o Hoover vault tanks include an outer ¢teel jacket which is UL-lishfLeg and e s a to ensure true 360 degree secondary containment of the primary inner tank- Alternate exposed concrete designs are generally not UL-listed for secondary containment since they rely on a lastio membrane around the inner tank for secondary containment. The Hoover out r steel jacket also protects the fire barrier fro weathering, cracking, spalling, or shrinking that can occur with exposed concrete designs. o Hovvrs vault T tank is constructs of minimum 3/7.611 thick steel with continuous welds on all sides, inside as moll TOM outside. Extra steel thickness maximizes resistance to pinpoint corrosion b acteria build-up in stored petroleum products. i 0 Hoover vault tanks utilize a special lightweight material as the internal fire barrier, resulting in aG 25W lour wei?ht compared to exposed concrete designs. o Lein-profile rcctangWaar design ainialaes need for stairs to access fill box and diapenser on top of t-k. Year-f2.af op design provides safe, stable personnel plat€ors for routine tank monitoring maintenance. Safer and easier to access th#n cylimArical tanks. o AID. Hoover vault tasks include at d leak detector tube to enable monitoring between the inner primary tank and o er aevondary containment tank. The UL-2085 Y , P listing provides assurance that the fire resistive liujmg will not hinder the tection of leaks. 0 Optional fiberglass exterior cladding I (Pibervault) provides guaranteed thirty year maintenance free exterior and additional prpteatioa from harsh environmental 0 All steel tank openings are NPT threaded, including leak detector tube. coaditioxts. o Hoover vault tanks include standard at no additional cost. o Hobver carries comprehensive liability insurance of $11 million to ensure future custoaaer support (copy of insurance certificate available upon request). o HOOVer vault tanks meet requirements of NFPA Sections 30 and 30A for aboveground storage tanks, as well as the Unifo Fire Gods Articles 52, 79, Appendix IIF, standard A-=z-F-1. o Hoover vault tanks can be grounded in accordance with NFPR-780. ` ---_ -- ..? 7703960622 P.05 The safe aboveground storage of fuel and other flammable liquids is regulated by fire codes such as Uniform Fire Code (UFC) Articles 52, 79, Appendix IIF, Standard A-11-F-1 and th( National :Fire Protection Association (NFPA Section 30 and 30A. These codes include stringent performance requirements to ensure a tank design includes proper secondary containment, two hour fire resistance, ballis is protection, and, vehicle impact resistance. How can; a customer determine if a part cular tank design requirements? Fortunately, Underwriters L rato meets these tough lieu ry (UL) has developed a test standard for aboveground storage tanks called UL-logy 82 NLsARILY CONTAnM- PROTECT33D TYPE. If a tank design ie submitted to UL and passes the stri6t series of tests required UL authorizes the tank manufacturer to plack a UL-20B5 SZCOMARZLY CONTA? the firecodes, TYPE label on each tank built using the ap?roved design. Thus, a customer can achieve regulatory compliance with the fire codes by purchasing a tank with a UL-2085 tSSGONDARYL7 CONTAIIPND, PROTRCTED Tres label, such as t ose manufactured by Hoover Group under GSA Contract #Q8-07F-9114G_ An earlier UL test standard, UL-2085 IHSDLATgn, rntm Rg9ISTANT TYRX, doss not meet all the new fire code quirements. Additionally, many common fire protected tari7c models are not 7.isted for se ndary containment. Therefore, the customer must be sure which UL label will be provided by the manufacturer.