Loading...
HomeMy WebLinkAboutSW1191001_18-161 - Supplemental EZ_11/26/2019SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Rutherfordtoh-Spindele Middle School Project Area ac 91.61 Coastal Wetland Area ac _ N/A Surface Water Area ac N!A Is this ro'ect High or Low Density? High 2 3 4 5 6 Does this project use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of ve etated setbacks provided (feet) j N/A 8 Will the vegetated setback remain vegetated? Yes 9 Is BUA other that as listed in .1003 4 c-d out of the setback? Yes 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 2 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 1 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Im ervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 IStormFilter 0 24 Silva Cell 0 25 Ba ilter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Organization: Kenneth Lorin - Prinet al 28 CLH Design PA 29 Street address: 400 Reaancv Forest Drive Suite 120 30 City, State, Zl : Cafy, NC 31 Phone numbers : 919.319.671E 32 Email: 87516 CCoallitation Slalemenl: aorlo- 7t'..irr"�' ''-I t•'•'illflli �_-:'1 _ .:'i --I: wilh the Inlormamn provided +tare � �4J �Ol ti±��F� ; ' •M1rz i 22 'S SEAL 23953 ••LaQ % Si alure Pf Designer /%•Z 6— Date DRAINAGE AREAS FEveIrsions? a hi h densit roject? Yesnumber of draina a areas/SCMs 2 art of this project subject to previous rule No FORMS LOADED _. , l� a IType of SCM - Wet Pond Wet Pond 5 JTotal BUA in project (sq ft 599243 sf 19ti675 sf 355606 sf 6 New BUA on subdivided lots (subject to ermittin s ft 0 0 0 7permitting) New BUA outside of subdivided lots (subject to sf 599243 sf 196675 st 355606 SF 8 Olisite • to area s9 ft sf sl sf 9 Offsite BUA(sq It) 0 0 0 10 Breakdown of new BUA outside subdivided lots: Parking (sq ft 91719 sf 0 91719 sf Sidewalk It) 67102 st 7778 sf 56516 sl Roof (sq ft 110907 sf 0 110907 sf _ Roadway s it 123753 s[ 30734 st 93019 sf - Future (sq ft 3445 sl 0 3445 st Other, please specify in the comment box below (sq ft 158163•sl 158i63 sl 0 11 New infiltrating permeable pavement on subdivided lots (sq ft 0 0 0 12 New infiltrating permeable pavement outside of subdivided lots (sq ft (} 0 0 13permitting) Exisitng BUA that will remain (not subject to s ft 61075 sf 0 0 14 Existing BUA that is alread armitted 11 0 0 0 15 Existina BUA that will be removed (sq f1 16921 sf 0 0 16 Percent BUA 150% 45% 30% 17 Desi n storm inches 1 1n 1 in 1 in 18 Design volume of SCM cu ft 18709 of 39578 cf 19 Calculet ien method for desig n volume HRT HRT AD1}EiIDHAL FORMATION 20 _ Please use this space to provide any additional information about the drainage aiaa(s): Other BUA Includes the track portion of track and field WET POND ­71Drainage area number I 2 2 Dos[gn volume 61 SCM (cu ftj 16582 of 31409 cf Is the SCM sized to treat the SW from all surfaces at build -out? Yob a es 3 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are The side slopes of the SCM (H:V)? 3:1 3:1 6 Does the SCM have retaining walls, gabton walls or other engineered side slopes? No No 7 Are the 'inlets, outlets, and receiving stream protected from erosion (10-year storm)? Yes Yes a Is there an overflow or bypass for -inflow volume in excess of the design volume? No No 9 What is the method for dewa[ering the SCM for maintenance? Drawdown Orifice Drawdown Orifice i0 If applicable, win [he SCM be cleaned out after construction? No No 11 Does the maintenance access comply with General MDC (8)? Yes Yes 12 Does the drainage easement comply with General MDC (9)? Yes Yes 13 tl the M s on a single family lot, does (will?) the plat comply with General MDC (10)? No No 14 Is there an O&M Agreement that complies with General MDC (11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes Yes 16 Does the SCM follow [he device specific MDC? Yes Yes 17 Was the SCM ft�gried by an NIC Hoen9ed pa sssgrW? WET 18 Meltiod used HRT Yes HRT 19 Has a stage/storage table been provided in the calculations? Yes Yes 20 Elevation of the excavated main pool depth (bottom of sediment removal) (Imsl) 99T00 994-50 21 Elevation of the main pool bottom-(k1p of sediment removal) (fmsl) 997.50 995.00 22 Elevation of the bottom of the vegetated shelf (fmsl) 1003.U 23 Elevation of the permanent pool (fmsl) 1003.0 24 Elevation of the top of the vegetated shelf (fmsl) 1004.0 25 Elevation of the temporary pool (fmsl) 1004.0 26 Surface area 01 the main permanent pool (square feet) 11780:1 2 Volume of the main permanent pool (cubic fee[ 40520of cf 28 Average depth of the main pool (feet) 3.99 Itt 29 Average depth equation used Equationquation 3 30 If using equation 3, main pool perimeter (feet) n/a n/a 31 II using equation 3, width of submerged veg. shelf (feet) Na n/a 32 Volume of the forebay (cubic feet) 6252 cf 18423 cf 33 Is this 15-20 % of the volume in the mainpool? Yes es 34 Clean -out depth for forebay (inches) 6 in Bin 35 Design volume of SCM (cu it) 18709 cf 39578 of 36 Is the outlet an orifice or a weir? Orillice Orifice 37 If orifice, orifice diameter (inches) 2 in 2.5 36 If weir, weir height (inches) n/a n/a 39 If weir, weir e n/a n/a 40 hinthes Drawdown t me Fo[heempo 2.9 4.1 41 Are the inlet(s) and outlet located in a manner that avoids short- circuiting? Yes Yes 42 Are berms or baffles provided to improve the flowpath? No No 43 Depth of forebay at entrance (inches) 54 in 54 in 44 Depth of forebay at exit (inches) 54 in 54 In 45 Does water flow out of the forebay in a non -erosive manner? Yes Yes 46 Width of the vegetated shelf (feet) 6 it 6 rt 47 Slope of vegetated shelf (H:V) 6:1 6:1 48 Does the orifice drawdown from below the top surface of the permanent pool? Yes Yes 49 Does the pond minimize impacts to the receiving channel from the 1 yr, 24-hr storm? Yes Yes 50 Are fountains proposed? (If Y, please provide documentation that MDC(9) is met.) No No 51 Is a trash rack or other device provided to protect the outlet system? Yes Yes 52 Are the dam and embankment planted in non -clumping turfgrass? Yes Yes 53 Species of turf that will be used on the dam and embankment _ a arcing p an peen provided rot the vegetateds os es TIONAL INFORMATION 55 use this space to pfavide any additional infgrmallon abuui the w81Please (s): Wet Pond 4 1:32 PM 11/26/2019