Loading...
HomeMy WebLinkAboutNCG080430_COMPLETE FILE - HISTORICAL_20110301STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /V C O� DOC TYPE ffr'HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ 3()Il 0.3 w YYYYMMDD Rea HCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary February 22"d, 2011 YRC, Inc. Attn: John P. Sypek 1077 George Boulevard, Suite B-471 Akron, OH 44310-2408 Subject: REPRESENTATIVE OUTFALL STATUS REQUEST NPDES General Stormwater Permit NCG080000 Certificate of Coverage NCGO80430 YRC, Inc. - Kernersvifle Forsyth County Dear Mr. Sypek: The Winston-Salem Regional Office staff have reviewed your request dated February 29th, 2008 for a determination that stormwater discharge outfall (SDO) 007 be granted representative outfall status for stormwater outfalls 003, 005 and 006. Based on the information and maps provided as well as a site visit by Ron Boone, of this office, on February 17th, 2011, we are approving this request. In accordance with 40 CFR §122.21(g)(7), you are authorized to sample outfall number 007 as a representative outfall. This approval is effective with the next sampling event. We also want to remind you that the permit still requires Qualitative Monitoring be performed at all SDOs, regardless of representative status. Also, please remember that any actions you initiate in response to benchmark exceedences as directed in the tiered response provisions of your permit must address all drainage areas represented by SDO 007, where appropriate. Please append this letter to your Stormwater Pollution Prevention Plan (SPPP) or permit to document that representative outfall status has been approved. If changes in drainage areas, structures, processes, storage practices, or other activities occur that significantly alter the basis of this approval, representative outfall status may no longer be valid. You should either resume sampling at all SDOs, or reapply to this office for representative outfall status based on updated information. If you have any questions or comments concerning this letter, please contact me at (336) 771-4967 or at ron.boone@ncdenr.gov. Sincerely, W. Corey asinger Interim Regional Supervisor Surface Water Protection Section cc: Winston-Salem Regional Office CCentFa—I'OffscelStorrnwafer Permitting Q7 ii Central North Carolina Division of Water Quality, Winslon-Salem Regional Office Location: 585 Waughtown 5t. Winston-Salem, North Carolina 27107 Phone: 336-771.50001 FAX: 336.771-46301 Customer Service: 1-877-623.6748 Intemet: www.newaterqual;ty.org An Equal Opportunity 1 Affirmative Action Employer NorthCarolina Naturalloy 4� NC®ENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary February 22rid , 2011 YRC, Inc. Attn: John P. Sypek 1077 George Boulevard, Suite B-471 Akron, OH 44310-2408 Subject: REPRESENTATIVE OUTFALL STATUS REQUEST NPDES General Stormwater Permit NCGO80000 Certificate of Coverage NCG080430 YRC, Inc. - Kernersville Forsyth County Dear Mr. Sypek: The Winston-Salem Regional Office staff have reviewed your'request dated February 29"', 2008 for a determination that stormwater discharge outfall (SDO) 007 be granted representative outfall status for stormwater outfalls 003, 005 and 006. Based on the information and maps provided as well as a site visit by Ron Boone, of this office, on February 171h, 2011, we are approving this request. In accordance with 40 CFR §122.21(g)(7), you are authorized to sample outfall number 007 as a representative outfall. This approval is effective with the next sampling event. We also want to remind you that the permit still requires Qualitative Monitoring be performed at all SDOs, regardless of representative status. Also, please remember that any actions you initiate in response to benchmark exceedences as directed in the tiered response provisions of your permit must address all drainage areas represented by SDO 007, where appropriate. Please append this letter to your Stormwater Pollution Prevention Plan (SPPP) or permit to document that representative outfall status has been approved. If changes in drainage areas, structures, processes, storage practices, or other activities occur that significantly alter the basis of this approval, representative outfall status may no longer be valid. You should either resume sampling at all SDOs, or reapply to this office for representative outfall status based on updated information. If you have any questions or comments concerning this letter, please contact me at (336) 771-4967 or at ron.boone@ncdenr.gov. Sincerely, ' W. Corey �asinger Interim Regional Supervisor Surface Water Protection Section cc: Winston-Salem.Regional_Office C nene #rat Office/Stormwater Permitting Unit Central Files North Carolina Division of Water OuaRy, Winston-Salem Regional Office Location, 585 Waughtown St. Winston-Salem, North Carolina 27107 Phone: 336-771-50001 FAX: 336-771-45301 Customer Service: 1-877.623-6748 Internet www,navaterquality.org An Equal opportunity 1 Affirmative Action Employer None rthCarolina Naturally NC®ENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary February 22nd, 2011 YRC, Inc. Attn: John P. Sypek 1077 George Boulevard, Suite B-471 Akron, OH 44310-2408 Subject: Compliance Evaluation Inspection NPDES General Stormwater Permit NCG080000 Certificate of Coverage NCG080430 YRC, Inc. - Kernersville Forsyth County Dear Mr. Sypek: 1. Ron Boone of the Winston-Salem Regional Office of the NC Division of Water Quality (DWQ) conducted a compliance evaluation inspection (CEI) at the subject facility on February 17tn, 2011. The assistance and cooperation of Pete Navarro, Cliff Evans and James Frei during the inspection, was greatly appreciated. An inspection checklist is attached for your records and the inspection findings are summarized below. 2. The facility is located at 1255 NC Hwy 66 South, in Kernersville, Forsyth County, North Carolina. Stormwater related to industrial activity is discharged from the site to the West Fork Deep River, which is currently classified as Class WS-IV (water supply) waters in the Cape Fear River basin. Documentation & Monitoring Review 3. The Stormwater Pollution Prevention Plan (SP3) is complete, current and has been implemented. You are reminded of the annual SP3 reviews and everything the permit requires as part of the annual reviews. Please review that section of the general permit in detail. Also, the site plan only reflects four oil/water separators (OWS), but in actuality there are six. Please update the site,.plan to show all six OWSs. Lastly, please begin keeping records of the maintenance of the O11VSs, including documentation of when you have the units pumped out. Training records were excellent and the actual SP3 was very well written. 4. The facility has performed analytical monitoring (AM) at stormwater discharge outfall (SDO) 007 only. This is the result of a request for Representative Outfall Status (ROS) submitted to the Division in 2008. A letter from the Division approving the ROS request was not available at the time of the inspection and is not in our files. However, Mr. Boone has agreed, in accordance with the 2008 request, that the sampling of SDO 007 is representative of the other SDOs (003, 005 and 006). Therefore, effective immediately, you are hereby granted ROS to AM SDO 007 as North Carolina Division of Water Quality, Winston-Salem Regional Office Location: 585 Waughtown St. Winston-Salem, North Carolina 27107 One Phone: 336-771-5000 l FAX: 336-771 A630 k Customer Service: 1-877.623-6748 North C arol ina Internet: www.ncwaterquality.org 'jVatumlly An Equal opportunity 4 Affirmative Action Employer `/ "J YRC, Inc. Attn: John P. sypek Compliance Evaluation Inspection, NCGO80430 2/2212011 Page 2 of 2 representative of all SDOs. Should site conditions change in the future such that this is no longer the case, you are obliged to contact this regional office for a review of your ROS. 5. Furthermore, for future reference, please realize that unless a permittee has signed documentation from the Division granting them an official waiver from the performance of any permit condition, then they are not relieved from those requirements. A permittee must hold written documentation from the Division relieving them of the responsibility of performing any specific permit requirements. if they do not hold such written documentation, failure to meet the permit condition is a violation of the permit. Site Review 6. The site was very clean and well maintained. Mr. Boone noted no violations or discrepancies. It is believed that you have minimized exposure of industrial activities to the maximum extent practical. 7. You are reminded that violations of the NCGO80000 general permit are subject to civil penalty assessments not to exceed $25,000 per day, per violation. Please correct any deficiencies noted above as soon as practical. Thank you for your cooperation in this matter. Should you have any questions, please feel free to contact Mr. Boone or me at (336) 771-5000. Sincerely, W. Corey Basinger Interim Regional Supervisor Surface Water Protection Section Attachments: 1. BIMS Inspection Checklist cc: SWP�W..SROO. Central Files Stormwater Permitting Unit Permit: NCGO80430 SOC: County: Forsyth Region: Winston-Salem Compliance Inspection Report Effective: 11/01/07 Expiration: 10/31/12 Owner: Y R C Inc Effective: Expiration: Facility: YRC, Inc:-Kernersville 1255 NC Hwy 66 S Contact Person: Jean Godwin Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 02/1712011 Primary Inspector: Ron Boone Secondary Inspector(s): Title: Entry Time: 09:00 AM &%4-- Kernersville NC 27284 Phone: 330-384-2324 Certification: Exit Time: 11:00 AM G /22-/// Phone: Phone: 704-663-1699 Ext2202 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Transportation wNehicle Maintenance/Petroleum Bulk/Oil Water Separator Stormwater Discharge COC Facility Status: Q Compliant ■ Not Compliant Question Areas: ® Storm Water (See attachment summary) Page: 1 k, Permit: NCGO80430 owner - Facility: Y R C Inc Inspection Date: 02/17/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Please refer to the attached inspection summary fetter. Page: 2 Permit: NCGO80430 owner - Facility: Y R C Inc Inspection Date: 02117/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ® n n n # Does the Plan include a General Location (USGS) map? ■ n n n # Does the Plan include a'Narrative Description of Practices'? ■ n n n # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ n n n # Does the Plan include a list of significant spills occurring during the past 3 years? © n n n # Has the facility evaluated feasible alternatives to current practices? ■ n n n # Does the facility provide all necessary secondary containment? ■ n n n # Does the Plan include a BMA summary? ■ n n n # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ fl n 0 # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ® n n n # Does the facility provide and document Employee Training? ■ n n n # Does the Plan include a list of Responsible Party(s)? ■ n n Cl # Is the Plan reviewed and updated annually? # Does the Plan include a Stormwater Facility Inspection Program? ■ n n n Has the Stormwater Pollution Prevention Plan been implemented? ■ n n n. Comment: Facility has a very good stormwater pollution prevention plan (SP3). Please refer to the attached inspection summary letter. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? e n n n Comment: Please refer to the attached inspection summary letter. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ■ n n Lj # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ■ n n n Comment: Not all monitoring has been done as required. Facility thought they had approved ROS status. Please refer to the attached inspection summary letter. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ n n n # Were all outfalls observed during the inspection? ■ n n n # If the facility has representative outfall status, is it properly documented by the Division? n ■ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ® n n n Page: 3 Permit: NCGO80430 owner - Facility: Y R C Inc Inspection pate: 0211712011 Inspection Type: Compliance Evaluation Reason for Visit: Routine Comment: Please refer to the attached inspection summary letter. Page: 4 1 r N.G. Dev%- of ENR JUN 0 J 20 �.�..... NCDENR YVin�tors 5al� North Carolina Department of Environment 1i09kenAi C' and Natural Reseurees-- -- Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary May 21, 2009 John Sypek . YRC, Inc. 1077 Gorge Blvd. Akron, OI-i 44310 Subject: NPDES General Permit NCG080000 _____Certificate,of _ Coverage-NCG0804.3 YRC, Inc. -Conover Formerly Roadway Express, Inc. Forsyth County Dear Mr. Sypek: On May 19, 2009, Division personnel received your request to revise your stormwater permit Certificate of Coverage to accurately include you new company name. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental .Protection Agency. If you have any questions, please contact the Sarah Young in the Stormwater Penmitting Unit at 919-807-6303. Sincerely, #v Coleen H. Sullins cc: DWQ Central Files Mooresv' a ffice Stor nwater Permitting Unit Wetlands and stormwater Branch 1617 Mail Service Center, Raleigh, Noah Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 9IM07-6300 4 FAX: 919-807.64941 Customer 5ervice:1-B77-623-6748 Internet: www.ncwaterquality.org IV M Ay 2 6 2009 Lt :rot ert,�z �L1i�n One NorthCarolina An Equal opportunity 1A imrat ve Action Employer rf STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCGO80000 CERTIFICATE OF COVERAGE No. NCGO80430 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Enviro_nmentai_Managemer�t - - - - Commission, and the_l.edera! %Vater-Poliution=Cdiited Act, as amended, ��^ YRC, INC. is hereby authorized to discharge stormwater from a facility located at YRC, INC. 1255 NC HIGHWAY 66 SOUTH KERNERSVILLE FORSYTH COUNTY to receivin waters designated as the West Fork Deep River, a class WS-IV strewn, in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in.Parts 1, 11, 111, 1V, V, and VI of General Permit No. NCGO80000 as attached. This certificate of coverage shall become effective May 21, 2009. This Certificate of Coverage shall remain in effect for the duration of the General Permit, Signed this day May 21, 2009. 4/aColeen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission 14 fr .'' CDEHR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director May 21, 2009 John Sypek YRC, Inc. 1077 Gorge Blvd. _ Akron, OH 44310 Dear Mr. Sypek: Dee Freeman Secretary Subject: NPDES General Permit NCG080000 Certificate-ofCoverage'NCG08043Q _ -- YRC, 1nc.-Conover Formerly Roadway Express, Inc. Forsyth County On May 19, 2009, Division personnel received your request to revise your stortnwater permit Certificate of Coverage to accurately include you new company name. Please find enclosed the revised Certificate of Coverage. The teens and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.I and the Memorandum of Agreement between North Carolina and the U.S. Environmental .Protection Agency. If you have any questions, please contact the Sarah Young in the Stormwater Permitting Unit at 9I9-807-6303. Sincerely, f' 4."Jg"� #fir Coleen H. Sullins cc: DWQ Central Files Mooresville Regional Office Stormwater Permitting Unit' Wetlands and Store water Branch 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 91M07-63001 FAX: 919-807-6494 4 Customer Service: 1$77.623-6748 Internet; www.nmaterquality.org An Equal Opportunity 4 Affirmative Action Employer Natimally NorthCawllna f STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO, NCG080000 CERTIFICATE OF COVERAGE No. NCGO80430 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental.Managemertt-- - - - �= - Commission, siid the_I ederal Water-Pollution=Control Act; s amended, YRC, INC, is hereby authorized to discharge stomiwater from a facility located at' YRC, INC. 1255 NC HIGHWAY 66 SOUTH KERNERSVI.LLE FORSYTH COUNTY to receiving waters designated as the West Fork Deep River, a class WS-IV stream, in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 11,111, IV, V, and VI of General Permit No. NCGO80000 as attached. This certificate of coverage shall become effective May 21, 2009, This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day May 21, 2009. -taColeen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission I4 r Services Grou February 29, 2008 8916 Oregon Inlet Ct. Raleigh, North Carolina 27603 Phone: 919.661.9954 Fax: 919.661.8108 Bradley Bennett, PE Stormwater Permitting Unit NCDENR-DWQ y 1617 MSC p Raleigh NC 27699-1617 o� RE: Roadway Express, Inc. — Winston-Salem NCG080430 �s Petition for Representative Outfall Status Dear Mr. Bennett: On behalf of my client, I am submitting this petition letter requesting representative outfall status for SDO-007. Refer to the enclosed Map 2 for the locations and drainage areas of this facility's outfalls. The following are our reasons for choosing SDO-007: SDO-007 has a variety of industrial activity within its drainage area, consisting of a portion of the terminal docks, the truck garage, covered service/ wash bay, fueling station, and tractor parking. Its drainage area is 939,444 sf and is 95% impervious. The end of the pipe is easily and safely accessible. We want to monitor this outfall because it gives a good representation of BMP effectiveness in the vicinity of the Garage. SDO-003 drainage area is limited to the terminal docks and trailer parking. SDO-006 drainage area, the smallest at this facility, is limited to trailer parking. SDO-005 drainage area is limited to terminal docks, trailer parking, and a portion of the facility maintenance shop. This outfall discharges from a wet detention pond, and usually has a flow throughout the year due to groundwater infiltration into the outfall's internal pipes. We have sampled the discharge from SDO-005 twice during the past Permit term; both times the parameters were significantly less than the benchmark values. We believe qualitative monitoring will suffice to detect any pollutant problems at SDO-005. In our opinion, SDO-007 is the preferable choice for analytical monitoring. There are no outfalls labeled SDO-001, SDO-002, or SDO-004. An old map indicated these points, but our field investigation showed that they were not separate point source discharges. We kept the same nomenclature for continuity. Mr. Bennett, Page 2 Representative Outfall Petition SpwSG We will assume that if no response from your office is forthcoming within 45 days following the receipt of this letter, then this petition is granted. In the meantime, if you have any questions, do not hesitate to call me. Sincerely, 7ames WATER SERVICES GROUP, LLC - AIC- D. Frei Senior Project Manager Enclosure. cc: Jean Godwin, YRC Worldwide (Akron, OH) Cliff Evans, Roadway Express (Winston-Salem, NC) File moo PROPER L Z E ------------------------------------------------r'—_-------------- — — — — — — — — — — — — — - — — — — — — — op of I NEW TERMINAL DOCK Lf ------------ I \\ f \ I .�• i `.. IMMMNM��NMI�MN MM.... N•....HpM................................................................... N.M ~~' ,,,� '•'— — — — — — — — — — 0 ---------+-------------------------� I I , EXPOSEDDRUMS AST-4 ti��� ......... It OVS# \ PAL.LM I \ I I � \ I� I 1 I \ f GARAGE i I rl FUELEM \�\\\ STTmN i • �I A --------------Q--•+ti .-.N t1 Y1 y---�....—�.-- ` ClIIf72 r AST G�, 00 > > o P 1 J W i-------4 1 EXPOSED ENGINES 1 1 1 1 a 1 1 a 1 > It C9871 ! �' � 1 of 1 l S DO-007 DA = 939,444 sf Imp = 95% OLD TERMINAL DOCK Y' CBM32 -----------•------------------+---------� ----- �......�1...................................... Y I L Y, IV TRANS I 1 !K AREA I Y TRAILER PARKING CBIl31 Y Y5 SDO-003 DA = 436,805 sf Imp = 100% WOODED �„�» EP RIVER TRIG TO VEST FORK DE PROPERT LINE CBN61 i I I Detention PoW FACILITY MAINTENANCE SHOP SDO-006 DA = 67, 406 sf Imp = i 00% WOODED WOODED 30 100 204 300 SDO-005 DA = 745,242 sf Imp = 95% 400 dew1oped for ROADWAY EXPRESS, INC. Winston -Sales G991T671 I V PMSi Stomw.d. Perm& No. NOCAOM9 Map Datm May u, 2047 llnwu Or n. FM i Mop Scaled See Mr Seale Owdied JWp Jbn Frei I SwSG SI..t. S.M. Group, LLC R.W* NC (919) 661-9954 1x 0 A Stormwater Services Group, LLC 8916 Oregon Inlet Ct. Raleigh, North Carolina 27603 Phone: 919.661.9954 Fax: 919.661.8108 February 29, 2008 Bradley Bennett, PE Stormwater Permitting Unit NCDENR-DWQ 1617 MSC Raleigh NC 27699-1617 RE: Roadway Express, Inc. — Winston-Salem NCG080430 Petition for Representative Outfall Status Dear Mr. Bennett: On behalf of my client, I am submitting this petition letter requesting representative outfall status for SDO-007. Refer to the enclosed Map 2 for the locations and drainage areas of this facility's outfalls. The following are our reasons for choosing SDO-007: SDO-007 has a variety of industrial activity within its drainage area, consisting of a portion of the terminal docks, the truck garage, covered service/ wash bay, fueling station, and tractor parking. Its drainage area is 939,444 sf and is 95% impervious. The end of the pipe is easily and safely accessible. We want to monitor this outfall because it gives a good representation of BN P effectiveness in the vicinity of the Garage. SDO-003 drainage area is limited to the terminal docks and trailer parking. SDO-006 drainage area, the smallest at this facility, is limited to trailer parking. SDO-005 drainage area is limited to terminal docks, trailer parking, and a portion of the facility maintenance shop. This outfall discharges from a wet detention pond, and usually has a flow throughout the year due ,to groundwater infiltration into the outfall's internal pipes. We have sampled the discharge from SDO-005 twice during the past Permit term; both times the parameters were significantly less than the benchmark values. We believe qualitative monitoring will suffice to detect any pollutant problems at SDO-005. In our opinion, SDO-007 is the preferable choice for analytical monitoring. There are no outfalls labeled SDO-001, SDO-002, or SDO-004. An old map indicated these points, but our field investigation showed that they were not separate point source discharges. We kept the same nomenclature for continuity. Mr. Bennett, Page 2 Representative Outfall Petition S"G We will assume'that if no response from your office is forthcoming within 45 days following the receipt of this letter, then this petition is granted. In the meantime, if you have any questions, do not hesitate to call me. Sincerely, STAR WATER S ERVICES GROUP, LLC games D. Frei Senior Project Manager Enclosure. cc: Jean Godwin, YRC Worldwide (Akron, OH) Cliff Evans, Roadway Express (Winston-Salem, NC) File WATT Michael F. Easley, Governor `O�� '9pG William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources UJ � [ Alan W. Klimek, P.E., Director Division of Water Quality 0 � August 23, 2002 ROBERT E ZIMMERMAN ROADWAY EXPRESS INC- KERNERS V ILLET671 1077 GORGE BLVD AKRON, OH 44309 Subject: NPDES Stormwater Permit Renewal Roadway Express Inc-Kernersville T671 COC Number NCGO80430 Forsyth County Dear Permittee: In response to your renewal application for continued coverage under general permit NCG080000, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency. dated December 6, 1981 The following information is included with your permit package: A new Certificate of Coverage A copy of General Stormwater Permit NCGO80000 A copy of a Technical Bulletin for the general permit Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact Delonda Alexander of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 584 Sincerely, Bradley Bennett, Supervisor Stormwater and General Permits Unit cc: Central Files Stormwater & General Permits Unit Files Winston-Salem Regional Office NCDENR Customer Service 1.800-623.7748 N. C. Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG080000 CERTIFICATE OF COVERAGE No. NCC080430 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, ROADWAY EXPRESS INC is hereby authorized to discharge stormwater from a facility located at ROADWAY EXPRESS INC- KERNERSVILL'E T671 1255 NC HWY 66 SOUTH KERNERSVILLE F'ORSYTH COUNTY to receiving waters designated as the West Fork Deep River, a class WS-IV stream, in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 1I, II1. IV, V, and VI of General Permit No. NCG080000 as attached. This certificate of coverage shall become effective September 1, 2002, This Certificate of Coverage-sball remain in effect for the duration of the General Permit. Signed this day August 23, 2002. for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Michael E. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources O`aOF W A r R0BERT E ZIN1?%,IIERIMAN ROADWAY I-XPRESS INC-KERNERSVIL 1072 GORGE BLVD AKRON, Ohl 44309 Dear Perrnitlec: Gregory J. Thorpe, Ph.D. Acting Director Division of Water Quality Dcccnlber 27.2001 Subject: NPDES Slormtvater Permit Renewal ROADWAY F,'XPRFvSS INC-KERNERSVII- COC Number- NCG080430 Forsyth County Your facility is currently COvcrcd for stornnvalcr disch[trge under Genera! Permit NCG080000. "Phis permitexpires on Au"ust 3l. 2002. The Division staff is currently in the process of rewriling this permit and is scheduled to h.ne the permit WiSSued by late: summer of 2002. Once the permit is r'CISSueCI, your facility would be eligible for cnntinuccl covcragc under the reissued permit - In order to assure your continued covcra-c under the general permit, you must apply 1O the Division of Water Quality (DWQ) fix- renewal ol'your permit coverage. To make this renewal process easier, we arc informing you in advance that your permit will be expiring. 1 ncloscd you will Find a Genera! Permit Coverage Renewal Application Form, The application must be completed and returned by March 4, 2002 in order to assure continued coverage under the gencrat permit. Failure to request renewal within this Lillie period nrty result in a civil assessment of at least $250.00. Larger penalties may be assessed depending on the delinquency of the request. Discharge of stormwatcr from your facility without covert,c under a valid stormwatcr NPDES permit would constitute a violation of NCGS 143-215.1 and could result in assessments 01' civil penalties of up to $10.000 per day. Please note that recent Iederal IeLIslation has extended the "no cxposurc exclusion° to all operators o! induS16,11 facilities in any crf the I I categories of "storni water discharges associated with industrial activity." (except consu-uct 011 ctcli%'16CS), if you feel your facility can certify a condition of "no exposure", i.e. the facilty industrial materials and operations are not exposed to stormwatcr, you can apply for the no exposure exclusion. for additional information contact the Central Office Storrs xater Staff mcmhcr lisled below or check the Storm.%vater SL General Permits Unit Weh Site [11 htlp://h2o.cur..sttrtC.nCus/su/Stormwatcr.htmt []'the suhject stormwaler discharge to waters ol' the slate has been terminated, please complete the enclosed Rescission Request Form. 11Mallin4 instructions are listed on the bottom of the form. You will be notified when the rescission process has been completed. Il'you have any questions regarding the hCrmit renewal procedures please contact Corey B LSinLTer of the' Winston-Salem Rc,ional Office at 3 36-771-4600 or Delonda Alexander Of the Central Office SLormwaler Unil at (919) 733- 08i , cxt. 584 Sincerely. I ` Bradlev Bennett- Supervisor Stormwater and GCr1CrLrl Permits Unit cc: CCnlrlll Files Winston-Salem Reglortnl Office ern NCDENR N. C. Division of Water Quality 1617 Mail Service Center Raleigh, NO 27699-1617 ' (919) 733-7015 Customer Service 1- 800-623-7748 State` -of North Carolina 156partment of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr,, Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director November 3, 1995 Ll Demastus Roadway Express Inc Box 471 Akron, OH 44309 Subject: General Permit No. NCG080000 Roadway Express Inc COC NCGO80430 Forsyth County Dear LI Demastus : In accordance with your application for discharge permit received on September 25, 1995, we are forwarding herewith the subject certificate of coverage to discharge under the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .l and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, this certificate of coverage shall be final and binding. Please take notice that this certificate of coverage is not transferable except after notice to the Division of Environmental Management. The Division of Environmental Management may require modification or revocation and reissuance of the certificate of coverage. This, permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any question concerning this permit. please contact MR. ANTONIO EVANS at telephone number 919/733-5083. cc: Winston-Salem Regional Office P.O. Box 29535, Raleigh, North Carolina 27626-0535 An Equal Opportunity Affirmative Action Employer Sincerely, OPJGlNAt_ SIGNED BY B ADLEY BENNER A. Preston Howard, Jr. F.E. Telephone 919-733-7015 FAX 919-733-2496 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO. NCG080000 CERTIFICATE OF COVERAGE No. NCG080430 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Roadway Express, Inc. is hereby authorized to continue operation of an oil water separator and discharge stormwater from a facility located at Roadway Express, Inc. 1255 N.C. Highway 66 South Kernersville, NC Forsyth County to receiving waters designated as West Fork Deep River in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I. IT, I[] and IV of General Permit No. NCGO80000 as attached. This certificate of coverage shall become effective November 3, 1995. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day November 3, 1995, G, -101NA . SIGNEO BY UPPADL EY EENNM A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Comnssion 1 STATE OF NORTH CAROLINA • DEPARTMENT OF CONSERVATION AND DEVELOPMENT RALEIGH. NORTH CAROLINA STANLEYVILL£ rS iM' E6,tgfE Z R 583 car. aioGF 6 Mr 150 44 (9E:LEWCREEK) 585 586 2'30" .i: r - C_ ••.•- •� = J. r, • rry water Ga+lp m 0231 •Wi -`� ••i•' �•..i+��r . �� �r��jn� I . Ft 06 • : /- 4WT 1501 ow WEISZ _ ! r L • I `a PTO. 8M 971 4 4�/ it "� - _- • - cl �`' � :mow U ___ •• -sp - ' '� \ 1 950c • y 41- - - ■c �=- n` t'#Bmker liilf_ •_ u' .� ,off Ch .-J 0 _ r 161 s .yy .t 1i iD ]" FACILITY: R dFjfl W pN L x ��L�S T oc, CouNTY: F C) ,r5 �4 k NPDES: N CCU U a 6'-t 3 C) MAP#• G l s 5 G DSN FLOW: N/A Sus BASIN: U 3 - C; — CU(9 LATITUDE: 3(I 6 O (D ! I S r/ LONGITUDE: S 04 U 3! 3 r n RECENING STREAM: We,-,k Fv r k Deep R t L)4 ' STREAM CLASS: W S DISCHARGE CLASS: STORMWATER EXPIRATION DATE: 6 /,3 / / � 7 1-4 C PROPERT LINE ----------y------------ r_------ � / I y I NEW TERMINAL DOCK r r I t T t I a � r � I k-----_.-__--- r-----,..--_--r-._--_--_-_.�---_-----__--- __--._-_.T__�.-_-- _-_^"-l- L r rL 'v`«....«........... ....DRAINAGE DIVIDE ......... CBM33 i %b\ \ r ♦ f -�'- �y.l CBN74 ................M... AST-1 , — `� ` OVSr4 t } I a ttt PALLETS I � I I C !/ ri I CBM73 —, ar+s�t ; { I y I \t } GARAGE YE ! FUELING tl I STATION I` i ii k a -co 11 yHy i ♦♦ �7a77 �� y y 1 1--_-__--_-- WASH BAY ly 1 l y = a 4 � E � yl CB#71 y, ��"" '"�'� i l'}VSll3 y i OVS02 + GUARD SHACK f O -���.-•""�'' y TRUCK ENTRANCE � L.. \ SDO-007 DA = 939,444 sf Imp = 95% OLD TERMINAL DOCK \ SCRAP DIN l ` \ cDl13a t�------------------------------•-------- ---i----r-REMOTE LURE I STATION 1V TRANS X AREA I I TRAILER PARKING SDO-003 DA = 436,805 sf Imp = 100% WOODED TR1B T4 VEST FORK DEEP PROPERTY LINE «1 CBMb1 H /r /r • •''�•� .'��� SDO-005 1 DA 745,242 sf k Imp - 95% I r Detention Pond C9055 t t: t ....�.r WOODED �• 5 FACILITY MAINTENANCE SHOP \ SD0 6 DA = 67, 406 sf Imp = 100% t i I I� i' i r` I WMUED t t 'i 0 50 too 200 300 400 30a �-Z_j .PLAN - ! I I developed for ROADWAY EXPRESS, INC. Winston-Salem G991 T671 NPDFS SbwmwwW Permh No. NCtiO>RIM Map Duct October 30, 2008 Draft By. JIm Feel Map scale: See By Beale meew By: Am Fret SwSG i9,.—ter slerrlees Q—P, uc R-w#►, me v19)rAt.m4