Loading...
HomeMy WebLinkAboutWQ0004332_Compliance Evaluation Inspection_20191018ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director Anne -Marie Knighton Town of Edenton PO Box 300 Edenton, NC 27932-0300 NORTH CAROLINA Environmental Quality October 18, 2019 SUBJECT: Compliance Inspection Report Town of Edenton WWTF Non -discharge Permit No. WQ0004332 Chowan County Dear Ms. Knighton: The North Carolina Division of Water Resources conducted an inspection of the Town of Edenton WWTF on 10/02/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0004332. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact Sarah Toppen with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at Sarah.Toppen@ncdenr.gov. Sincerely, Ismah Joppv� Sarah Toppen, Environmental Specialist Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: WQS Washington Regional Office - Enforcement File NON -DISCHARGE Compliance/Enforcement Unit - Enforcement File North Caro ra Departmert of Ery for rrems Qrs tp I D vsorof Water Resources Wash rgtor. Reg'oraDffoe 1943 Wash rgtor SaLsre Ma' I Wash rgtor, North Caro^ra 27889 252-e48-6481 Compliance Inspection Report Permit: WQ0004332 Effective: 12/01/14 Expiration: 11/30/19 Owner : Town of Edenton SOC: Effective: Expiration: Facility: Town of Edenton VWVfF 614 Macedonia Rd County: Chowan Region: Washington Edenton NC 27932 Contact Person: Anne -Marie Knighton Title: Phone: 252-482-7352 Directions to Facility: System Classifications: SI, Primary ORC: David Wayne Myers Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 10/02/2019 Primary Inspector: Sarah A Toppen Secondary Inspector(s): Entry Time: 09:50AM Robert B Tankard Reason for Inspection: Routine Permit Inspection Type: Wastewater Irrigation Facility Status: ❑ Compliant N Not Compliant Question Areas: Certification: 1001733 Phone: 252-333-8105 Exit Time: 12:OOPM Phone: 252-946-6481 Phone :252-946-6481 Ext.233 Inspection Type: Compliance Evaluation Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Flow Measurement -Water Treatment Barscreen Record Keeping Use Records Treatment Lagoons End Use -Irrigation Treatment Disinfection Treatment Flow Measurement Wells (See attachment summary) Page 1 of 5 Permit: W00004332 Owner - Facility: Town of Edenton Inspection Date: 10/02/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary A Compliance Evaluation was completed on October 2, 2019, with Sarah Topper, Robert Tankard, and Megan Davis present with NC Division of Water Resources. Present with the town was David Myer, ORC and Corey Gooden for there part of the inspection. The facility is currently under a Special Order by Consent(SOC) due to poor field conditions. The ORC is spraying on the field less (only 2-2.5 hours at a time) than before the SOC and it seems to be helping. There are still sections that have surface runoff, ponding and vegetative crop issues. There was six feet of freeboard at the lagoon. The ORC spoke about becoming Field Laboratory Certified. To find out more information about this certification call Tom Halvosa at 919-733-3908 Ext. 273. The facility is in noncompliance due to the conditions of the fields. Keep following the SOC time schedules. If you have any questions let us know. Page 2 of 5 Permit: w00004332 Owner - Facility: Town of Edenton Inspection Date: 10/02/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Reuse (Quality) ❑ Infiltration System ❑ Activated Sludge Spray, LR ❑ Single Family Spray, LR ❑ Activated Sludge Drip, LR ❑ Activated Sludge Spray, HR ❑ Recycle/Reuse ❑ Single Family Drip ❑ Lagoon Spray, LR Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? 0 ❑ ❑ ❑ Is flowmeter operating property? M ❑ ❑ ❑ Does flowmeter monitor continuously? 0 ❑ ❑ ❑ Does flowmeter record flow? M ❑ ❑ ❑ Does flowmeter appear to monitor accurately? 0 ❑ ❑ ❑ Comment: The flow meter was calibrated on 11-28-2018 by CIS Treatment Flow Measurement -Water Use Records Yes No NA NE Is water use metered? 0 ❑ ❑ ❑ Are the daily average values properly calculated? 0 ❑ ❑ ❑ Comment: Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ Comment: The flow meter was calibrated on 11-28-2018 by CIS. Treatment Barscreen Yes No NA NE Is it free of excessive debris? M ❑ ❑ ❑ Is disposal of screenings in compliance? 0 ❑ ❑ ❑ Are the bars spaced properly? M ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment Page 3 of 5 WI ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Z ■ ■ ■ ■ ■ ■ ■ Z ■ 'EMEMEME00000000 Cl. O U w C N� 'N N 6 Cl' +U 7 w y C m O E N 0 d O f0 M a) � II fl_ Q) a) C <0 23 N C C O 75 O 01 N O N C O N U ), as E- W O iBE U 'v £ w NN N 0 a) N EN O O) N � N N cl- C:' CD o N N N U Q U m m O L m C N C a7 O U N Z N ca L O7 y WIDDOODOODOODDOOD cl- Q' N Q Z ca > C N N a d S 0 c C j O N. U C � C i O 0 a C Z 0 O U E U m N Q 3 a a N .n N LD Cl. > N > a) U N d 7 p_ a N a O cl. N d f0 a7 > L U -0 m U O a) 7 M C N a N d O a c (7 O O J C N N C O O U O N D E h n Y a) Q Q Q N 'O N C (0 a) U x aD C O c U C U C () VE a) O 0 L % cc > d (0 3 N a 0 0 Q N N 'O 0 0 U (n m Z 7 Q c d cc N N Q Q # # y9: 11 Permit: W00004332 Owner - Facility: Town of Edenton Inspection Date: 10/02/2019 Inspection Type: Compliance Evaluation Reason for Visit: Routine If so, has it been applied? ❑ ❑ Are operational logs present? E ❑ ❑ ❑ Are lab sheets available for review? 0❑ ❑ ❑ Do lab sheets support data reported on NDMR? N ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? 0 ❑ ❑ ❑ Are Operational and Maintenance records present? 0 El El ❑ Were Operational and Maintenance records complete? 0 ❑ ❑ Has permittee been free of public complaints in last 12 months? ❑ ❑ El E Is a copy of the SOC readily available? ❑ ❑ ❑ 0 No treatment units bypassed since last inspection? E ❑ ❑ ❑ Comment: April 2019 spot check was completed. The soils report was dated August 9 2019 and all the lops and paperwork appear to be avaliabe and in order. End Use -Irrigation Yes No NA NE Are buffers adequate? ❑ ❑ Is the cover crop type specified in permit? ❑ 0 ❑ ❑ Is the crop cover acceptable? ❑ ❑ Is the site condition adequate? El 0 ❑ ❑ Is the site free of runoff / ponding? ❑ E ❑ ❑ Is the acreage specified in the permit being utilized? ❑ 0 ❑ Is the application equipment present? 0❑ ❑ ❑ Is the application equipment operational? 0❑ 11 ❑ Is the disposal field free of limiting slopes? 0 ❑ ❑ ❑ Is access restricted and/or signs posted during active site use? 0 ❑ ❑ El Are any supply wells within the CB? ❑ ❑ El N Are any supply wells within 250' of the CB? ❑ ❑ How close is the closest water supply well? El ❑ El E Is municipal water available in the area? 0 ❑ ❑ ❑ # Info only: Does the permit call for monitoring wells? ❑ ❑ Are GW monitoring wells located properly w/ respect to RB and CB? ❑ ❑ ❑ Are GW monitoring wells properly constructed, including screened interval? 0 ❑ ❑ Are monitoring wells damaged? ❑ 0 El ❑ Comment: the facility is currently under an SOC because the spray irrigation fields have surface runoff, ponding and vegetative crop issues. MW-2 was locked and appeared to be in good condition. Page 5 of 5