Loading...
HomeMy WebLinkAboutWinston Salem 421 Quarry-FIG-1 EXISTING SITE FENCING DETAILP.- � 310-000 � 314-511 � —CADD � Dwg � CVO1 FIG—CVO1—EXIS77NG FENCE DETAIL. dwg(F1G-1 EXISTING FENCEI LS.•(11/8/2021 — mrjohnson) — LP.- 111812021 4.02 PM TOP RAIL OR TENSION WIRE LINE POSE BRACE RAIL GRAIN—UNK /FABRIC (9 GAGE, 2 MESH) F LINE POST ^� CORNER, END, OR PULL POST E WIRES R CUPS 5 ; OF FAABRIC 7FN�SION ' TR ' 2" (3/8USS" MINROD. DN.) •.,' rWI _ p T. 1 1/2" MIN GRADE HOG RINGS (TYP.) 16" MIN. DIA. I CONCRETE BASE I 2 1/2" MAX II 10" MIN. DIA. CHAIN -LINK SECURITY FENCE DETAIL TENSION BAND (15" O.C. MAX. NU tiUALL AND WITHIN 4" FROM TOP AND BOTTOM OF FABRIC) FABRIC TRUSS ROD (3/8" MIN. DIA. CONCRETE BASE 1 1/2" (TYP) TRUSS ROD AND BAND TOP RAIL OR TENSION WIRE PULL LINE POST BRACE RAILS- 7 TRUSS ROD TRI STEEL POST SCHEDULE MINIMUM OUTSIDE DIMENSIONS NOMINAL USE AND SECTION FABRIC WIDTH 72" OR LESS FABRIC WIDTH 64" TO 96" FABRIC WIDTH 108" AND OVER CORNER, END & PULL POSTS 2.375" O.D. 2.875" O.D. 4.00" O.D. TUBULAR - ROUND TUBULAR - SQUARE 2.00" SQ. 2.50" SQ. 3.00" SQ. C-SECTION (ROLL -FORMED) 3.50" X 3.50" 3.50" X 3.50" LINE POSTS TUBULAR - ROUND 1.90" O.D. 2.375" O.D. 2.875" O.D. H-SECTION 2.25' X 1.70" 2.25" X 1.70" 2.25" X 1.70" C-SECTION (ROLL -FORMED) 1.875" X 1.625" 2.25" X 1.70" TOP, BOTTOM & BRACE RAILS 1.66" O.D. TUBULAR - ROUND 1.50" SQ. TUBULAR - SQUARE 1.625" X 1.50" H-SECTION 1.625" X 1.25" C-SECTION (ROLL -FORMED) TENSION BAND TENSION BAR TO ENGAGE EACH FABRIC LINK TENSION BAR TRUSS ROD CARRIAGE BOLT (3/8" MIN. DIA.) ROUND POST END OR GATE POST DETAIL BARBED WIRE OR TENSION WIRE H-BEAM BRACE RAIL CLAMP DETAILS TENSION BAND DETAIL FASTENING DETAILS NO SCALE LINE POST BRACE RAILS TENSION WIRE - 3/4" DIA. COPPER -CLAD STEEL GROUND ROD FENCE POST #8 AWG SOLID COPPER WIRE -0" MOLDED EXOTHERMIC WELD OR APPROVED CLAMP -TYPE FITTING OF COPPER 10,-0" BRACE PANEL DETAIL NOTE: NO SCALE PROVIDE BRACE PANEL GROUNDING DETAIL WHENEVER STRAIGHT NO SCALE RUNS EXCEED 500 FEET. CHAIN LINK FENCE NOT TO SCALE 9-GAGE STEEL TIE WIRES (2'-0" O.C. MAX.) FABRIC TOP OR BRACE RAIL ATTACHMENT NOTES, 1. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND ARE NOT INTENDED TO LIMIT OTHER TYPES OF FENCE SECTIONS AND METHODS OF INSTALLATION THAT COMPLY WITH THE SPECIFICATIONS. 2. WIRE TIES, RAILS, POSTS, AND BRACES SHALL BE CONSTRUCTED ON THE SECURE SIDE OF THE FENCE ALIGNMENT. CHAIN -LINK FABRIC SHALL BE PLACED ON THE SIDE OPPOSITE THE SECURE AREA. 3. UNLESS SPECIFICALLY SHOWN OR SPECIFIED, ALL FENCE SHALL HAVE AN APRON EXTENDED OUTWARD FROM THE AREA BEING PROTECTED. 4. C-SECTION POSTS SHALL BE INSTALLED SO THAT THE VOID INSIDE THE POST IS COMPLETELY FILLED WITH CONCRETE UP TO THE TOP OF THE FOUNDATION. STEEL TM WIRE 9—GAGE STEEL nE WIRE 4;.—.E 15" O.C. MAX. AND (15" O.C. MAX. AND WITHIN 4" FROM TOP WITHIN 4" FROM TOP AND BOTTOM OF FABRIC) AND BOTTOM OF FABRIC) H-BEAM ROUND POST LINE POST ATTACHMENTS NO SCALE VULCAN MATERIALS OMPANY F7 11MM'"YAWAV � WI STON SALEM 421 QUARRY Civil & Environmental Consultants, Inc. FORSYTH COUNTY, NORTH CAROLINA 3701 Arco Corporate Drive • Suite 400 - Charlotte, NC 28273 Ph: 980.237.0373 • Fax: 980.237.0372 EXISTING CHAIN LINK FENCE DETAIL www.cecinc.com DRAWN BY: MRJ CHECKED BY: SWW I APPROVED BY: SWW FIGURE NO.: DATE: NOVEMBER 2021 DWG SCALE: N.T.S. I PROJECT NO: 314-511