Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-Detail Sheets-401-Details
LaBeLLa Powered by partnership. 0 0 � M c Q U Y ,> � U L fn C- Q U OD a�i c_ a Q O F- M co CV C-3 o o � CV Cn ; U-) CO LO M .. O N O CV H o6 } a L Ma_ d BY OTHERS BRIDGE PLAN T/GRADE 0 v CROSS SECTION A -A 5'-0" TOP OF DAM NOTES: • MEASUREMENTS ARE TO THE INSIDE CRESTS OF THE CORRUGATION • DIMENSIONS ARE SUBJECT TO MANUFACTURING TOLERANCES NOTE: THE SETTLING PONDS WILL BE REMOVED WHEN THE RECLAMATION PLAN IS COMPLETED IN THE FIELD. Q 100' WIDTH TOP OF BERM WATER SURFACE ELEVATION = 595 FT FOUNDATION 1L ELEVATION = 594 FT � 1 BY OTHERS 2.5 1 1 2.5 BOTTOM ELEVATION = 579 TAILING POND #1 *PRELIMINARY FOUNDATION DESIGN NOTES: • PRELIMINARY SIZING BASED ON ASSUMED 8000 PSF BEARING CAPACITY, 4'-1" OF COVER, AND CAT 773 LIVE LOADING • SCOUR NOT CONSIDERED IN THIS PRELIMINARY DESIGN • FINAL DESIGN MAY VARY CONTECH METAL ARCH BRIDGE CULVERT NTS 18" RETRIEVAL ROPE SKIMMER PROTECT WEIR WITH FILTER FABRIC AND RIPRAP FILTER FABRIC 3 o w CD D- � M 4" OR 6" PVC 5'x3'x18" 6" STONE APRON WITH FILTER FABRIC NOTES: 1. USE FOR DRAINAGE AREAS NOT EXCEEDING FIVE ACRES. 2. EARTH BERM SHALL BE STABILIZED w/SEEDING ACCORDING TO TOWN SPECIFICATIONS. DESIGN OF SPILLWAYS DRAINAGE AREA WEIR LENGTH 1 (ACRES) (FT) 1 4.0 2 6.0 3 8.0 4 10.0 5 12.0 1DIMENSIONS SHOWN ARE MINIMUM FILTER FABRIC BAFFLES WITH METAL T-POST, WOVEN WIRE FABRIC BACKING AND COIR FIBER NETTING �T z i �-II=1I1-1I1� 11-1II=1II-1II=1II-1II=1_ -1�1 ICI III III ICI III III III III- I LENGTH SKIMMER BASIN CROSS SECTION LINE WEIR WITH RIPRAP WEIR LENGTH PVC I -III -III -III -III -III=' I II PIPE I111-111-I11111 11i111- 11� I�IIIIIII111IIIIIIIIIi� WEIR CROSS SECTION DITCH AND BURY FILTER FABRIC EDGE (MIN. 12" OF FABRIC) MAINTENANCE • INSPECT TEMPORARY SKIMMER BASIN AND EMPTY SKIMMER OF ALL DEBRIS AFTER EACH PERIOD OF SIGNIFICANT RAINFALL. REMOVE SEDIMENT AND RESTORE BASIN TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE BASIN. PLACE THE SEDIMENT THAT IS REMOVED IN A DESIGNATED DISPOSAL AREA. REPAIR BAFFLES. • CHECK THE STRUCTURE FOR DAMAGE FROM EROSION OR PIPING. PERIODICALLY CHECK THE DEPTH OF THE SPILLWAY TO ENSURE IT IS A MINIMUM OF 1.5 FEET BELOW THE LOW POINT OF THE EMBANKMENT. IMMEDIATELY FILL ANY SETTLEMENT OF THE EMBANKMENT TO SLIGHTLY ABOVE DESIGN GRADE. ANY RIPRAP DISPLACED FROM THE SPILLWAY MUST BE REPLACED IMMEDIATELY. • STABILIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE BASIN IMMEDIATELY AFTER CONSTRUCTION WITH SEEDING AND MATTING, AS NEEDED. TEMPORARY SKIMMER BASIN (2 OF 2 NTS 100' WIDTH 10, �_ i TOP OF BERM WATER SURFACE ELEVATION = 591 FT 255 11F ELEVATION = 584 FT -1 12 5 BOTTOM ELEVATION56 F7 TAILING POND #2 NOTE: EACH TAILING POND SHALL HAVE A MINIMUM FREEBOARD OF 1.0 FEET AND SHALL HAVE DIMENSIONS AT THE SURFACE OF 500 FEET LONG BY 100 FEET WIDE. THE SLOPES OF THE OUTER SIDES OF THE TAILING PONDS WILL VARY DEPENDING ON THE SURROUNDING SURFACE. TAILING POND DETAIL NTS BAFFLES WITH METAL T-POST, WOVEN WIRE FABRIC BACKING AND COIR FIBER NETTING - SEE BAFFLE DETAIL (THIS SHEET) BOTTOM ANCHORED WITH STAPLES SKIMMER WITH RETRIEVAL ROPE TOP OF DAM 5'-0"--, , WEI STONE APRON WITH FILTER FABRIC sFo�M��r PERSPECTIVE VIEW TEMPORARY SKIMMER BASIN (1 OF 2 NTS NOTES: 1. SKIMMER IS TO BE A SURFACE DEWATERING DEVICE SUCH AS BMP SKIMMER OR APPROVED DEVICE. 2. SKIMMER SHOULD RISE TO LEVEL OF WEIR HEIGHT IN TEMPORARY BASIN OR TO RISER INLET. 3. ROPE ATTACHED TO SKIMMER TO HELP KEEP CLEAN. 4. SIZING OF ORIFICE TO ALLOW FOR DEWATERING TIME OF 24-72 HOURS. RIGID FLEXIBLE JOINT OUTLET END: CONNECTIO TO OUTLET PIPE OR RIS SKIMMER DETAIL NTS NOTES: 1. DRIVE STEEL FENCE POST AT LEAST 18 INCHES INTO SOLID GROUND. 2. WOOD POST ARE NOT ACCEPTABLE. 3. DIRECT WATER TO TOP OF BASIN USING STABILIZED DITCH, SLOPE DRAIN PIPE OR OTHER APPROVED METHOD. BAFFLE DETAIL CORR FIBER MATTING. SECURE WITH NYLON ZIP TIES. 36" MIN. ZIP TIES I FLOW DIRECTION STAPLES WOVEN WIRE FABRIC - MIN. SECURE WITH NYLON ZIP TIESI T-POST Uf11\I\LL rlrL LVIVVLI\ II If11V JIIV YYIV. NOT INCLUDED WITH SKIMMER SUPPLIED BY USER. )PE 615 St. George Square Suite 300 Winston-Salem, NC 27103 336-842-4065 C#0430 label lapc.com F T 0� F��GoN � T � © 2019 LaBella Associates ALAMANCE AGGREGATES, LLC Mr. Chad Threatt, VP Alamance County Mine N0: DATE: DESCRIPTION: REVISIONS PROJECT NUMBER: 2180544 DRAWN BY: KCG/ATC REVIEWED BY: PAS ISSUED FOR: REVIEW DATE: 5/8/19 DRAWING NAME DRAWING NUMBER: SITE DETAILS C401