Loading...
HomeMy WebLinkAbout20230906_Liner_Basis_of_Design_DRAFT P � � ^ ■V,`��� � Piedmont Lithium Carolina, Inc. 42 E Catawba St. LITHIUM Belmont, NC 28012 September 6, 2023 Mr. Adam Parr, PE NC Department of Environmental Quality Division of Energy, Mineral, and Land Resources 1612 Mail Service Center Raleigh, NC 27699-1612 Subject: Piedmont Lithium Carolinas, Inc. Carolina Lithium Project ADI#3—Partial Draft Response Dear Mr. Parr: Piedmont Lithium Carolinas, Inc. (PLCI)submitted a North Carolina Mine Permit Application on August 30, 2021 to the Division of Energy, Mineral, and Land Resources (DEMLR). DEMLR issued an Additional Information request on October 29, 2021 (ADI#1) and PLCI responded to ADI#1 on December 15, 2021. DEMLR issued an ADI#2 on January 14, 2022 and PLCI provided a partial response to ADI#2 on June 20, 2022 with final complete response to ADI#2 on May 1, 2023. On May 30, 2023 DEMLR issued an ADI #3 request in which DEMLR stated the requirement of an engineered liner to be placed under the waste rock pile as a portion of the request. HDR Engineering of the Carolinas, Inc. (HDR) and Marshall Miller & Associates (MMA) have supported PLCI in developing a liner system and monitoring and treatment plan for the waste rock pile area and associated sediment basins. In the following, please find a partial draft response to portions of ADI #3 for review. Should you have any questions or require additional information following your review of the enclosed materials, please contact me, Monique Parker at (704) 813-2301 or mparker(a�piedmontlithium.com. Yours truly, J. Monique Parker, CSP Senior Vice President, Safety, Environment& Health Piedmont Lithium Carolinas, Inc. Page intentionally left blank. PIEDMONT Liner System Basis LITHIUM of Design (Draft) Carolina Lithium Project Piedmont Lithium Carolinas, Inc. Gaston County, North Carolina September 6, 2023 Page intentionally left blank. Piedmont Lithium Carolinas,Inc.I Carolina Lithium Table of Contents Table of Contents Introduction ...................................................................................................................................1 Background ...............................................................................................................................1 Selected Waste Rock Pile Liner System...................................................................................1 Selected Sediment Basin Liner System ....................................................................................2 Monitoring and Treatment Plan.................................................................................................2 DesignEvaluation.........................................................................................................................3 HELPModel Evaluation ............................................................................................................3 HELPModel Assumptions.....................................................................................................3 HELPModel Results..............................................................................................................4 HELPModel Conclusion........................................................................................................4 Sediment Basin Liner Equivalency........................................................................................5 Geotechnical Investigation ........................................................................................................5 GroundwaterSeparation........................................................................................................5 ExistingSoils .........................................................................................................................5 Conclusion ....................................................................................................................................5 Appendix A— Geotechnical Engineering Report Appendix B — Operational Details on Waste Rock Pile Construction and Sequencing (DRAFT) Appendix C —Waste Rock Pile Monitoring and Treatment Plan (DRAFT) Appendix D — Sediment Basin GCL Equivalency i Piedmont Lithium Carolinas,Inc.I Carolina Lithium Table of Contents Page intentionally left blank. H Piedmont Lithium Carolinas,Inc. I Carolina Lithium Introduction Introduction Background On May 30, 2023 DEMLR issued an Additional Information Request # 3 (ADI #3) which stated the requirement of an engineered liner to be placed under the waste rock pile. The following encompasses PLCI's response with support from HDR Engineering of the Carolinas, Inc. (HDR) and Marshall Miller&Associates (MMA)to develop the required liner system and monitoring and treatment plan for the waste rock pile area and associated sediment basins. The waste rock pile area encompasses approximately 120-acre area (Sheets OOC-1, OOC-2, Sheets CS-1 to CS-7, and Sheets 02CO-G005 to 02CO-D005 attached separately). The preparation and construction of the clay liner system is estimated to take 22 months. The subsequent construction of the waste rock pile is expected to take approximately 22 months over two major phases, after which it will be reclaimed and vegetated. There are 10 sediment basins surrounding the waste rock pile that will receive stormwater runoff and contact runoff from the waste rock pile during construction and stormwater runoff and contact runoff during operations. There are seven groundwater monitoring well locations around the waste rock pile to monitor the quality of groundwater. Once the liner system is in place, waste rock from mine pit excavation will be transported via a conveyor system to the waste rock pile area. Concentrator Plant tailings will be intermingled with the waste rock (mixed at transfer points on the conveyor belt) and transported via the same conveyor system to the waste rock pile. Material contained in the waste rock site will consist predominantly of coarse waste rock produced from the mine site, with a small portion of the material consisting of fine waste rock generated from the concentrator plant. The coarse waste rock, which is approximately 93-95% of the material to be placed in the above ground pile, is crushed through a primary jaw crusher to minus 14-inch size. The finer material, the concentrator plant tailings (minus 1 mm material), makes up the remaining approximately 5-7% of material to be placed in the pile. A geotechnical study (Appendix A) was conducted at the Site to include 17 borings in the waste rock pile footprint. The report discusses many parameters pertinent to the development of the liner system including extensive geotechnical testing of on-site soils for parameters such as soil classification and strength, as well as the depth to groundwater at the waste rock pile area. Selected Waste Rock Pile Liner System Based on the short exposure duration of 22 months while the waste rock pile is being constructed and considering the limited potential to produce elevated constituents only for the first flush under specific conditions based on the Leaching Environmental Assessment Framework (LEAF) and Accelerated Weathering of Solid Materials Using a Modified Humidity Cell (ASTM D 5744-96) 1 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Introduction Collaboration Technical Summary,' the decision was made to design a clay liner system as the hydrologic barrier against infiltration into the ground surface beneath the waste rock pile. The selected engineered liner system for evaluation consists of a minimum of two feet of compacted clay conditioned and compacted to achieve a permeability no greater than 1 x 10-7 (1 E-7) cm/sec. The construction of the clay liner system (eight stages) is expected to take approximately 22 months prior to the placement of Phase 1 waste rock (Appendix B).The process for liner construction will be conducted in eight stages with each stage following a stepwise sequence as follows: clear and grub; proof roll the subgrade; place, condition and compact the clay liner; and place, condition and compact the minimum two-foot-thick protective overburden layer. The protective overburden layer is to maintain the clay liner integrity from environmental condition impacts and act as a buffer from waste rock placement operations. Near the end of Phase 1 waste rock placement, Phase 22 will commence and includes structural fill placement to provide groundwater buffer followed by liner placement. Once the Phase 2 liner is in place, the Phase 2 waste rock can be placed. In total, the liner installation and the Phase 1 and Phase 2 waste rock placement will take approximately 44 months (Appendix B). This design was evaluated using the Hydrologic Evaluation of Landfill Performance (HELP) tool distributed by the United States Environmental Protection Agency (USEPA) to model water migration through the stockpile and clay liner system in order to assess the effectiveness of the clay barrier system. Selected Sediment Basin Liner System The waste rock pile has 10 sediment basins around the perimeter that are designed to collect and manage the runoff from a 25-year, 24-hour storm event. These basins will act as the collection point for the erosion and sedimentation control runoff as well as the collection and treatment for contact water from the waste rock during operations. PLCI has decided to line the ponds to enhance the environmental protection in areas where there will be hydraulic head build up and potential contact water treatment. The proposed liner system will consist of a 60-millimeter (mil) High Density Polyethylene (HDPE) membrane over a geosynthetic clay liner (GCL). Monitoring and Treatment Plan To compliment the requirement for a liner under the waste rock pile, a draft Waste Rock Pile Monitoring and Treatment Plan has been developed (Appendix C). The monitoring parameters selected for surface water and groundwater are based on those commonly required in mining ' Leaching Environmental Assessment Framework(LEAF)and Accelerated Weathering of Solid Materials Using a Modified Humidity Cell(ASTM D 5744-96)Collaboration Technical Summary(dated April 2023); prepared by Marshall Miller&Associates 2 In advance of Phase 2 construction activities(structural fill,liner system,waste rock placement),a modification to the existing Clean Water Action Section 404/401 Individual Permit will be required for the stream impact. 2 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Design Evaluation applications, parameters listed in the NCG02 General Permit for Lithium Ore Mining, and the results of the humidity cell and LEAFS test work report. In addition to routine sampling as proposed in the draft Waste Rock Pile Monitoring and Treatment Plan, PLCI will also conduct continuous monitoring of the pH and flow rate at the inflow and outflow of the 10 basins (Sheet CS-5)and weekly monitoring of the pH and water level is proposed in each of the seven groundwater monitoring wells. Design Evaluation HELP Model Evaluation HDR utilized the HELP v4.0 spreadsheet analysis to model the effectiveness of the proposed clay liner barrier system. The HELP model functions by using weather data (precipitation, solar radiation, wind, evapotranspiration, etc.) for an area and a layer building function to model how water moves through the waste rock pile. The user inputs the liner design data in the Soil & Design portion of the application, and the application applies the weather data to determine how much rain falls, how much evaporates, how much is absorbed by plants and soil, how much is collected by lateral drainage layers and eventually, how much of the water builds up and percolates through the liner barrier system. HELP analysis was conducted on the 1 E-7 clay liner configuration, utilizing 150 feet of waste rock, two feet of protective overburden layer and two feet of 1 E-7 clay liner. The Average Annual Totals Summary from the model's output was used to evaluate the clay liner configuration to determine how much of the design precipitation would percolate through the bottommost liner layer in an average year across 25 years of weather data. The results of the model output are presented below. HELP Model Assumptions The model was established on a per acre basis to reflect the entire waste rock pile cross-section. For the purposes of analysis several assumptions were made as follows: Stormwater • This scenario assumes a conservative zero runoff of rainfall in the modeled area and no internal piping in the stockpile for drainage breaks. • Weather data was selected for the Gaston County area. 3 Leaching Environmental Assessment Framework(LEAF)and Accelerated Weathering of Solid Materials Using a Modified Humidity Cell(ASTM D 5744-96)Collaboration Technical Summary(dated April 2023);prepared by Marshall Miller&Associates 3 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Design Evaluation • The model was run for 25-years to be consistent with the stormwater design period for erosion and sedimentation control permitting, however the stockpile will only be operational for 22 months. Material Layers • The topmost layer of the waste rock pile area was assumed to be Waste Rock with an average thickness of 150 feet and a hydraulic conductivity of 1.34E-2 cm/s. • The protective overburden layer was modeled as two feet thick and a hydraulic conductivity of 1 E-4 cm/s for the native, on-site overburden material anticipated to be used for protective cover. • The clay barrier layer was modeled as two feet thick and a hydraulic conductivity of 1 E-7 cm/s. • For each layer, the program material texture was chosen that would best represent the hydraulic conductivity of the selected liner. • These layers are constructed on top of the existing ground surface and will maintain the average natural grade 6.5% slope. HELP Model Results The results characterize the performance of the 1 E-7 clay liner system as protective of the environment by preventing 97.18% of the average annual rainfall from percolating through the clay barrier liner (Table 1). The 2.82% that percolates through the clay barrier system equates to 1.25 inches of water annually. Table 1. HELP Model Results. Liner Avg. Annual Percolation Percentage of Avg. Annual Configuration Through Bottommost Clay Rainfall Percolating (%) Layer inches Clay Liner 1 E-7 1.249 2.82 It should be noted that the model was run for a 25-year period to coincide with the stormwater and erosion control design period and assumed to have zero runoff. However, the waste rock pile is anticipated to be completed within 22 months after the liner system is installed and capped with a soil layer to encourage runoff rather than infiltrating and further reducing the amount of water available to percolate through the clay barrier layer. Given that the protective overburden layer is two feet thick, the clay liner is two feet thick, and the groundwater separation is at minimum five feet in the Phase 2 area (Sheet CS-7) and as much as 50 feet below the existing ground surface in the Phase 1 area, the percolation quantity into groundwater is significantly limited by the function of the clay liner system and its placement on top of the existing ground surface and on top of the structural fill in Phase 2. HELP Model Conclusion The modeled performance of the two-foot thick 1 E-7 clay liner with the two-foot-thick protective overburden layer is environmentally protective of the groundwater, considering the very short life 4 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Conclusion of exposed material in the waste rock pile area (22 months), and the limited volume of water percolating through the clay was modeled at an average of 1.25 inches per year. Sediment Basin Liner Equivalency In the sediment basins (SB1-SB10), a geosynthetic clay liner (GCL) subgrade will be utilized. A 60-mil HDPE geomembrane will provide added protection against Ultraviolet (UV) light degradation and exposure during operations. The USEPA equivalency demonstration comparing two feet of 1 E-7 cm/s clay layer versus a GCL for placement in the sediment basins is included in Appendix D using Darcy's equation. Geotechnical Investigation The geotechnical study conducted at the Site included 17 borings in the waste rock pile footprint (Appendix A). Groundwater and geotechnical information were obtained to aid further in the evaluation. Groundwater Separation Groundwater separation from the bottom of the barrier system is typically required and provides an additional level of environmental protection. Based on the groundwater level readings taken from the borings onsite the groundwater surface ranges from 10.9 feet to 50.0 feet below ground surface. There is an intermittent stream in the Phase 2 area as shown on Sheets CS-1 to CS-4. It is anticipated that a minimum five feet of structural fill material will be placed in this area to provide a buffer from groundwater to the base of the clay barrier liner system. Existing Soils Based on the geotechnical study (Appendix A), surficial soils on the Site range from clays, sandy clays, sandy silts, and silts. Unified Soil Classifications for onsite soils include MH, CL, ML, SM, and SC classification and in depths exceeding 10 feet. The results of the geotechnical report show that many of the on-site surficial soils are the types of materials that could obtain the 1 E-7 cm/s hydraulic conductivity and in sufficient quantities. A detailed material source characterization will need to be conducted to determine the exact location and quantities of suitable materials for use in the clay barrier layer. The geotechnical soils data was also used to confirm the material textures used in the HELP Model analysis. Conclusion The objective of the liner system is to provide a barrier to limit contact water from the waste rock infiltrating into the groundwater. The liner system will take approximately two years to place, followed by approximately 22 months of waste rock pile construction, after which it will be reclaimed and vegetated. Given the short exposure duration, the chosen liner barrier system modeled was two feet of 1 E- 7 cm/s clay. Onsite geotechnical data was used in the HELP modeling to determine average annual percolation rates through the clay barrier liner system. The model was run for a 25-year period to be consistent with the erosion and sedimentation control design storm. 5 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Conclusion The results indicate that the clay barrier system will prevent 97.18% of the average annual rainfall from percolating through the clay barrier liner and only 2.82% may percolate through the clay barrier system. Combined with the separation to groundwater, which ranges from five to 50 feet from the base of the clay barrier liner system, provides significant environmental protection buffer for the minimal percolation rate. In the sediment basins where there will be increased hydraulic head build up, a composite liner system consisting of a GCL overlain by a 60-mil HDPE geomembrane will be installed. In the sediment basins, the GCL will provide equivalency to a standard two-foot 1 E-7 cm/s clay barrier liner and the added geomembrane thickness will help protect against UV light degradation due to exposure. 6 Appendix A — Geotechnical Engineering Report Page intentionally left blank. Geotechnical Engineering Report for Piedmont Concentrator Definitive Feasibility Study Project Gaston County, NC January 13, 2022 January 13, 2022 Mr. Jim Nottingham, PE Senior Project Manager Piedmont Lithium Carolinas, Inc. 5706 Dallas-Cherryville Highway Bessemer City, NC 28016 Reference: Piedmont Concentrator Definitive Feasibility Study (DFS) Gaston County, North Carolina Geotechnical Engineering Report for the Proposed Waste Rock Disposal Area & Stream and Roadway Crossings Dear Mr. Nottingham: HDR Engineering Inc., of the Carolinas (HDR) has completed the subsurface exploration within the Waste Rock Disposal area and at the steam and roadway crossings at the Piedmont Lithium Carolinas, Inc. (PLCI) Project Site. This work was performed in general accordance with HDR's MSA 2019 Task Order Number 03 (PLCI Purchase Order No. PLCI-PO-21-002) dated March 3, 2021. The purpose of this exploration was primarily to provide foundation recommendations for the proposed facilities and structures. This report provides a summary of relevant project information, exploration test methods, test boring logs, laboratory test data, our interpretations and conclusions of the data, and recommendations for the facilities and structures. HDR appreciates the opportunity to provide geotechnical engineering services for this project. If you have any questions or need any additional information, please contact us. Sincerely, HDR ENGINEERING, INC. OF THE CAROLINAS 11 SEAL 039763 •• . I►���:: ' �•- � •'•,,p�v�than° ■•`'++ Paul Zhang, Ph.D., P.E. Kenny R. Bussey, Jr., PE Senior Geotechnical Project Manager Geotechnical Section Manager Mark P. Filardi, LG Project Manager hdrinc.com 555 Fayetteville Street Suites 900&210Raleigh,NC 27601-3034 (919)232-6600 Table of Contents Tableof Contents..................................................................................................................... 3 1.0 Project Description .......................................................................................................... 5 2.0 Purpose and Scope of Services ...................................................................................... 5 3.0 Project Information .......................................................................................................... 5 3.1 Regional Geology ........................................................................................................ 6 4.0 Subsurface Exploration ................................................................................................... 6 4.1 Geotechnical Data Collection....................................................................................... 6 5.0 Subsurface Data.............................................................................................................. 7 5.1 Geotechnical Data ....................................................................................................... 7 5.2 Groundwater Measurements........................................................................................ 9 6.0 Laboratory Testing Results.............................................................................................10 6.1 Classification Testing..................................................................................................10 6.2 Consolidation Test Results .........................................................................................11 6.3 Triaxial Shear Test Results.........................................................................................12 7.0 Engineering Evaluations and Recommendations............................................................12 7.1 WRDA.........................................................................................................................12 7.2 Bridge at Stream Crossing No. 1.................................................................................13 7.3 Whiteside Road Tunnel...............................................................................................14 7.4 Bridge at Stream Crossing No. 2.................................................................................16 7.5 Haul Roads.................................................................................................................17 7.6 Structural Fill Material .................................................................................................17 7.7 Site Preparation and Earthwork ..................................................................................18 7.8 Temporary Excavation and Support............................................................................18 7.9 Groundwater Control and Dewatering.........................................................................19 8.0 Limitations......................................................................................................................19 hdrinc.com 555 Fayetteville Street Suites 900&210Raleigh, NC 27601-3034 (919)232-6600 Tables: Table 5-1 Groundwater Summary.............................................................................................. 9 Table 6-1 Soil Classification Summary......................................................................................11 Table 6-2 Consolidation Test Results........................................................................................12 Table 6-3 Results of Triaxial Shear Testing...............................................................................12 APPENDICES: APPENDIX A— Subsurface Exploration Data • Boring Location Plan • Subsurface Profiles • Legend • Test Boring Logs APPENDIX B — Laboratory Test Results hdrinc.com 555 Fayetteville Street Suites 900&210Raleigh, NC 27601-3034 (919)232-6600 Piedmont Lithium I Geotechnical Engineering Report Project Description 1 .0 Project Description Based upon the site plans and Scope of Geotechnical Services provided by Piedmont Lithium Carolinas, Inc. (PLCI), and our subsequent conversations, HDR understands PLCI is developing an open-pit lithium quarry, located approximately 25 miles west of Charlotte, North Carolina, in the Carolina Tin-Spodumene belt, including a Quarry Concentrator Plant, Non-process Infrastructure, and a Waste Rock Disposal Area (WRDA) containing process tailings, waste rock, and overburden stockpiles. Two arch bridges are proposed along the haul roads at the stream crossings, and one tunnel is proposed underneath the proposed main haul road along Whiteside Road crossing. 2.0 Purpose and Scope of Services The purpose of this investigation is to identify and evaluate subsurface conditions at the PLCI facility within the proposed plant area for the concept site development project. Geotechnical and groundwater data were collected from geotechnical borings advanced during this project. The purpose of this report is to summarize findings from our subsurface exploration and provide site preparation, general construction, and foundation recommendations for the proposed structures and facilities. The following services were provided in support of the preceding objectives: • Executed a program of subsurface exploration consisting of subsurface sampling and field-testing. The program included thirty-six (36) Standard Penetration Test (SPT) borings, and collection of relatively undisturbed "Shelby" tube samples. • Visually classified and tested representative samples using the Unified Soil Classification System (USCS). Visual field classifications were performed in general accordance with the American Society of Testing and Materials (ASTM) standards. • Collected groundwater level measurements after a stabilization period of approximately 24 hours. • Performed laboratory testing (by HDR and our subconsultant Summit Engineering) in general accordance with ASTM Standards. Testing consisted of classification testing (grain size analysis, Atterberg Limits and natural moisture content), consolidation, and triaxial shear (CU). • Analyzed field and laboratory data. • Prepared this formal engineering report, summarizing the course of study pursued, the field and laboratory data generated, subsurface conditions, and geotechnical recommendations for the proposed structures and facilities. 3.0 Project Information The project is located at the PLCI site in Gaston County, North Carolina and is an approximately 1,548-acre tract of land located west of the intersection of Whitesides Road and Hephzibah Church Road, approximately 2.7 miles east of Cherryville, NC. The site, which is being evaluated FN Piedmont Lithium I Geotechnical Engineering Report Subsurface Exploration for development, is predominantly rural agricultural land with residences, outbuildings, ponds, and wooded areas. 3.1 Regional Geology Based on the Geologic Map of North Carolina, the site is located in the Piedmont Physiographic Province, which lies between the Coastal Plain and the Blue Ridge Mountains. Along the border between the Piedmont and the Coastal Plain, elevations range from 300 to 600 feet above sea level. To the west, elevations gradually rise to about 1,500 feet above sea level at the foot of the Blue Ridge Mountains. This site is located within this elevation range with boring collar elevations ranging from approximately 833.5 to 874.5. The Piedmont is characterized by gently rolling, well rounded hills and long low ridges and valleys which contain a network of streams. Within the upland areas away from alluvial deposits, soils within the Piedmont Province are the residual product of in-place chemical and physical weathering of parent rock materials. The typical residual profile consists of finer grained silts and clays near the ground surface which gradually transition to coarser and denser material with depth. The boundary between soil and rock is typically not sharply defined and a transitional zone, termed "weathered rock" is typically encountered overlying the more competent bedrock. Weathering is facilitated by joints, fractures and by the presence of less resistant rock types. Therefore, the profile of residual soil, weathered rock, and rock can be irregular and erratic, even over short distances. Based on the 1985 Geologic Map of North Carolina, the rock type mapped at the project site is the Cherryville Granite, an intrusive rock of the Inner Piedmont Belt. This unit contains pegmatites and is noted as being lithium-bearing on the east side, where the proposed mine would be located. No seismic faults are mapped in the vicinity of the project site. 4.0 Subsurface Exploration 4.1 Geotechnical Data Collection Previously, ECS Carolinas, LLC (ECS) performed 37 geotechnical borings in 2019 within the proposed project area as part of a Preliminary Subsurface Exploration. All of these boring logs are included with the historical ECS geotechnical report. In March and April 2021, HDR performed 10 Geotechnical SPT borings in accordance with ASTM D1586 within the proposed Concentrator Plant area (refer to our Geotechnical Report dated July 13, 2021). In August through October 2021, HDR performed 36 more SPT borings within the footprints of WRDA, at the stream and roadway crossings, and other proposed facilities. Both hollow stem auger and mud rotary with tricone bit drilling techniques were utilized and SPT split spoon drives were performed using an automatic hammer at 2.5-foot intervals in the upper 10 feet of every borehole, and at five-foot intervals below 10 feet. HDR personnel monitored the drilling operations, visually classified the samples, and prepared field logs of the explorations. Most boreholes remained open but covered for 24 hours after drilling to obtain a stabilized groundwater 6 FN Piedmont Lithium I Geotechnical Engineering Report Subsurface Data reading. All boreholes were backfilled with bentonite and sealed either immediately after drilling or after groundwater measurements were obtained. In order to monitor groundwater fluctuation, four monitoring wells were installed at boring locations GT21_4, GT21_7, GT21_11, and GT21_16. Boring collar elevations were interpolated from the existing topography data provided by PLCI and should only be considered approximate. Geotechnical samples were transported to HDR's office for further examination and classification by a geotechnical Engineer. Representative samples were subjected to classification testing. All soil samples were visually reviewed and classified by a North Carolina Professional Engineer (PE) or a North Carolina Licensed Geologist (LG). Final boring logs were prepared and stratified in general accordance with the Unified Soil Classification System (USCS) as described by ASTM D2487. The strata contact lines represent approximate boundaries between the soil types; the actual transition between the soil types in the field may be gradual in both the horizontal and vertical directions. Boring logs and lab testing data are presented in Appendix A and Appendix B, respectively, of this document. 5.0 Subsurface Data 5.1 Geotechnical Data The information contained within this section of the report summarizes the subsurface conditions encountered in the HDR subsurface exploration. WRDA A total of seventeen (17) borings (GT21_1 and GT21_2, GT21_4, GT21_7 through GT21_11, GT21_13, GT21_15 and GT21_16, GT21_19 and GT21_20, GT21_24 and GT21_25, GT21_28 and GT21_28) were drilled within the footprint of the proposed WRDA. Residual soils were encountered below surficial topsoil in all borings to depths ranging from approximately 13 to 174 feet. These soils consist primarily of silts and silty sands (ML, MH, SM). To a lesser extent, sandy clays (CL) were encountered at some locations. SPT N-values within residual soils ranged from 2 to 85 blows per foot. Residual soils appeared moist to wet. Weathered rock was encountered underneath residual soils in all borings and extend to depths ranging from approximately 24 to 174 feet (boring termination depths for some borings). Weathered rock is defined herein as residual material with an N-value of at least 100 blows per foot. Tricone refusal, which indicates competent rock, was encountered in some borings at depths ranging from approximately 60 to 144 feet. Streaming Crossing No. 1 An arch bridge is proposed to cross the stream along the Main Haul Road near Station 13+00 to 14+30. Four (4) borings (RC21_5 through RC21_8) were drilled, two on each side of the stream. On the west side of the stream, alluvial soils were encountered near the ground surface and extended to a depth of approximately 28 feet, consisting of sandy clays (CL), sands with gravel FN Piedmont Lithium I Geotechnical Engineering Report Subsurface Data and boulders, and silty sands (SP, SM). Alluvial soils appeared moist to wet. Residual soils were encountered below alluvium to depths ranging from approximately 30 to 34 feet, consisting of silty sands (SM) and appearing wet. Weathered rock was encountered below residual soils and extended to depths ranging from approximately 34 to 39 feet, at which tricone refusal was encountered indicating competent rock. It should be noted that boulders were encountered at boring RC21_5 between depths of 6 and 10 feet and will most likely affect the construction. On the east side of the stream, alluvial soils were also encountered, but only present in the top 1 to 2 feet, consisting of moist silty sands (SM). Residual soils were encountered below alluvium to depths ranging from approximately 10 to 11 feet, consisting of silts and silty sands (ML, MH, SM) and appeared moist to wet. Weathered rock was encountered below residual soils and extended to a depth of approximately 12 feet, at which tricone refusal was encountered indicating competent rock. Roadway Crossing at Whiteside Road A tunnel is proposed along the existing Whitesides Road to cross underneath the Main Haul Road near Station 35+30. Four (4) borings were proposed, but only two (RC21_1 and RC21_3) were drilled due to property access issues. Residual soils were encountered below surficial topsoil in both borings and extended to a depth of approximately 37 feet on the south side, and to the boring termination depth of 30 feet on the north side. These soils consisted of sandy clays (CL) underlain by sandy silts and silty sands (ML, SM). SPT N-values within residual soils ranged from 4 to 32 blows per foot. Residual soils appeared moist to wet. Weathered rock was encountered below residual soils in boring RC21_1 and extended to a depth of approximately 38 feet, at which tricone refusal was encountered indicating competent rock. Streaming Crossing No. 2 An arch bridge is proposed to cross the stream along the South Pit Haul Road near Station 13+40 to 14+00. Four (4) borings (RC21_9 through RC21_11) were drilled, two on each side of the stream. On the west side of the stream, at boring RC21_9, alluvial soils were encountered near the ground surface and extended to the boring termination depth of approximately 29 feet, at which tricone refusal was encountered indicating potentially competent rock. At boring RC21_12, alluvial soils were encountered near the ground surface and extended to a depth of approximately 19 feet, consisting of sandy silts (ML), silty and clayey sands, and sands with gravel (SM, SC, SP). Alluvial soils appeared dry to wet. Residual soils were encountered below alluvium and extended to the boring termination depth of approximately 49 feet, at which tricone refusal was encountered indicating competent rock. Residual soils consisted of silty sands (SM) and appeared wet. On the east side of the stream, at Boring RC21_10, large boulders were encountered and caused tricone refusal at a depth of approximately 7 feet with three attempts. At Boring RC21_11, large boulders were encountered and caused tricone refusal at a depth of approximately 11 feet with 8 FN Piedmont Lithium I Geotechnical Engineering Report Subsurface Data three attempts. Alluvial soils consisted of sandy clays (CL), silty sands (SM), and boulders, and appeared dry to wet. Miscellaneous Facilities Nine (9) additional borings (GT21_17, GT21_18, GT21_21, GT21_22, GT21_26, GT21_30 through GT21_33) were drilled throughout the site for miscellaneous facilities. Residual soils were encountered below surficial topsoil in all borings at depths ranging from approximately 9 to 60 feet (boring termination depths for some borings). These soils consisted primarily of silts and silty sands (ML, MH, SM). To a lesser extent, sandy clays (CL) were encountered at some locations. SPT N-values within residual soils ranged from 1 to 60 blows per foot. Residual soils appeared moist to saturated. Weathered rock was encountered below residual soils in some borings and extended to depths ranging from approximately 18 to 24 feet (boring termination depths for some borings). Tricone refusal, which indicates competent rock, was encountered in some borings at depths ranging from approximately 24 to 44 feet. It should be noted that the subsurface soil stratification is generalized to highlight major subsurface stratification features and material classifications. Specific details concerning subsurface conditions and materials encountered at each test location may be obtained from the soil test boring logs, and subsurface profiles located in Appendix A. The depths of strata indicated in the boring logs represent approximate boundaries between soil types; however, the actual transition may be gradual. 5.2 Groundwater Measurements Static groundwater elevations on site generally varied with topography and ranged from approximately 806 to 857 feet above sea level. Some boreholes caved in after drilling equipment was extracted, and therefore, static groundwater depth could not be measured. Approximate groundwater elevations and the depths to groundwater from the surface are shown in Table 5-1 below. Table 5-1 Groundwater Summary FBoring Boring ID Collar Groundwater Groundwater Elevation (ft) Depth (ft) Elevation (ft) GT21_1 856.0 50.0 806.0 GT21_4 854.9 43.0 811.9 GT21 7 869.5 28.9 840.6 GT21 9 834.2 17.0 817.2 GT21 11 869.6 13.1 856.5 GT21 13 851.9 10.9 841.0 GT21 16 853.3 45.8 807.5 GT21 19 864.7 12.6 852.1 9 FN Piedmont Lithium I Geotechnical Engineering Report Laboratory Testing Results Fluctuation in groundwater elevations should be expected throughout the year due to varying rainfall and temperature conditions, and perched groundwater should be expected above less permeable fine-grained materials and lenses of weathered rock overlying residual soil. 6.0 Laboratory Testing Results Representative spilt-spoon and Shelby tube samples were selected from the test borings to verify visual field classifications and evaluate engineering properties. Laboratory tests were performed by HDR and Summit Engineering in general accordance with ASTM standards and are summarized below. 6.1 Classification Testing A total of 26 samples were tested for Atterberg limits, natural moisture content, and grain size analysis. The results of these tests, as shown in Table 6-1, indicate that site soils range from silty sand to sandy clay(SM to CL), with moisture content ranging from approximately 9 to 69 percent. Most soils appear to have moisture contents at or above anticipated optimum levels and will likely require drying during construction. In addition, highly plastic soils (MH, CH) are susceptible to shrink and swell with fluctuations in moisture and are not suitable for reuse as structural fill. Refer to the test results in Appendix B for additional information. 10 Piedmont Lithium I Geotechnical Engineering Report Laboratory Testing Results Table 6-1 Soil Classification Summary Natural Passing Atterberg Limit Boring ID Sample Depth (ft) Moisture USCS Content #200 Sieve LL PL PI GT21 17 SS-4 8.5-10 33.1% 69% 53 37 16 MH GT21 21 SS-4 8.5-10 29.0% 54% 34 24 10 CL GT21 31 SS-1 1-2.5 20.5% 80% 48 30 18 ML GT21 31 SS-4 8.5-10 42.0% 61% 52 45 7 MH GT21 33 SS-1 1-2.5 20.7% 70% 49 29 20 ML GT21 18 SS-6 18.5-20 56.6% 71% 61 57 4 MH GT21 25 SS-7 23.5-25 47.4% 46% 46 32 14 SM GT21 26 SS-1 1-2.5 8.9% 38% NP NP NP SM GT21 28 SS-5 13.5-15 43.4% 55% 52 46 6 MH GT21 32 SS-1 1-2.5 20.0% 69% 47 29 18 ML RC21 1 SS-1 1-2.5 27.2% 79% 54 44 10 MH RC21 1 SS-6 18.5-20 60.5% 68% 55 55 NP MH RC21 1 SS-7 23.5-25 54.9% 52% NP NP NP ML RC21 3 SS-1 1-2.5 13.3% 53% 35 23 12 CL RC21 11 SS-2 3.5-5 17.2% 39% 27 18 9 SC RC21 11 SS-4 8.5-10 32.6% 36% NP NP NP SM GT21 20 SS-3 6-7.5 44.6% 84% 56 47 9 MH GT21 20 SS-5 13.5-15 58.0% 69% 51 47 4 MH GT21 24 SS-2 3.5-5 36.0% 69% 50 42 8 MH GT21 13 SS-1 1-2.5 26.9% 57% 46 28 18 ML GT21 13 SS-5 13.5-15 54.7% 58% 58 49 9 MH GT21 9 SS-4 8.5-10 28.1% 66% 56 35 21 MH GT21 9 SS-5 13.5-15 35.8% 53% 54 35 19 MH GT21 19 ST-1 15-17 61.8% 37% 59 58 1 SM GT21 19 ST-2 18-20 69.1% 45% 68 64 4 SM GT21 19 ST-3 21-23 66.7% 53% 63 60 3 MH 6.2 Consolidation Test Results Three (3) laboratory consolidation tests were performed on the low blow count materials (silty fine sand and elastic silt) obtained from boring GT21_19 at depths ranging from approximately 15 to 23 feet. Test results indicate the soils are over-consolidated and have compression index (Cc) values ranging from 0.68 to 0.85, and recompression index values (Cr) ranging from 0.06 to 0.07. The coefficient of consolidation (Cv) ranges from 0.198 to 0.252 square inches per minutes, indicating the soils are fairly drainable. It should be noted that the samples appear to have some disturbance. Therefore, variations in the consolidation properties should be anticipated. Test results are summarized in Table 6-2 below and are provided in Appendix B for reference. FN Piedmont Lithium I Geotechnical Engineering Report Engineering Evaluations and Recommendations Table 6-2 Consolidation Test Results Sample Moisture Depth Soil Type Content Preconsolidation Initial Void C� v Boring No. (ft) (USCS) (nt Pressure(ksf) Ratio eo CrC, (in /min) GT21 19 15-17 SM 61.8% 6.36 1.797 0.83 0.04 0.252 GT21 19 18-20 SM 69.1% 3.58 1.965 0.83 0.04 0.198 GT21 19 21-23 1 MH 66.7% 3.38 1.927 0.85 0.05 0.246 6.3 Triaxial Shear Test Results Triaxial shear testing was performed on the same undisturbed samples obtained for the consolidation tests, (i.e., the low blow count silty fine sand and elastic silt) obtained from boring GT21_19 at depths ranging from approximately 15 to 23 feet, for the purpose of obtaining the shear strength parameters of cohesion and the internal angle of friction (total and effective). Test results indicate that the soils have total cohesion (c) values ranging from 450 to 530 pounds per square foot (psf), total angle of internal friction values ranging from 9.4 to 12.2 degrees, effective cohesion (c') values ranging from 210 to 280 pounds per square foot (psf), and effective angle of internal friction values ranging from 27.8 to 31.8 degrees. Test results are summarized in Table 6-3 below and provided in Appendix B for reference. Table 6-3 Results of Triaxial Shear Testing Sample Moisture Total Total Friction Effective Cohesion Effective Friction Angle Boring No. Depth Soil Type Content Cohesion c Angle T c' cp' (ft) (USCS) (%) (psf) (°) (psf) (°) GT21 19 15-17 SM 61.8% 640 11.7 480 30.0 GT21 19 18-20 SM 69.1% 640 11.1 230 33.5 GT21 19 21-23 MH 66.7% 620 11.1 470 28.0 7.0 Engineering Evaluations and Recommendations Based upon our review of soils and geologic information, and results of the test borings and laboratory analysis, there are several geotechnical considerations which may affect the proposed construction, groundwater control, and reuse of on-site materials. These issues are discussed in greater detail in the following sections. 7.1 WRDA Based upon the provided Plans dated August 25, 2021, the proposed WRDA footprint is approximately 3,700 feet long and 2,100 feet wide. The proposed slope of the WRDA is 2H:1 V and a minimum 20 feet wide bench for every 60 feet horizontally, which results in an effective slope of 3H:1V. The finished grade of the crest is at 1,090 feet, the existing grades within the center of the WRDA footprint are at approximately 862 to 880 feet, which results in approximately 210 to 228 feet of waste rock disposal fill. 12 FN Piedmont Lithium I Geotechnical Engineering Report Engineering Evaluations and Recommendations According to PLCI, the waste rock will be crushed in the pit and conveyed to the WRDA. The top size of the crushed/conveyed material is estimated to be 14 inches. Blasted rock will be transported via a conveyor from the pits to the WRDA. Waste rock from pit excavation will be spread in nearly horizontal lifts using a bulldozer or other earth-moving equipment. The maximum loose lift thickness shall not exceed six (6) feet. Final grading of slopes will be completed with a dozer. The surface of the WRDA will be graded to drain to the approved system of ditches, benches, and flumes. Tailings from the processing plant will be disposed of as backfill into mined pits or in the WRDA. Most tailings are expected to be backfilled into mined pits. Tailings placed in the WRDA will be placed near the center of the fill. Compressible soils (SPT N-values generally < 6) consisting of sandy silts and silty sands exist throughout the WRDA site. To evaluate the compressibility of the soils, HDR performed settlement analyses for the proposed WRDA utilizing elastic and consolidation methods. Parameters for the settlement analyses were obtained from the consolidation testing as well as interpretation from SPT borings and laboratory test results. Settlements in the fine-grained silts and clays versus the coarser-grained sands will occur at different rates. The settlements in coarser grained, non-plastic materials are typically treated as elastic or immediate settlements and will occur upon or shortly after the application of load. The settlements in the finer grained and more plastic layers will occur over a longer period of time and are considered consolidation related settlements. Settlement of new fills is largely unavoidable regardless of the degree of compaction employed by the Contractor. Typically, we have observed properly compacted fills to settle between 2-6% of the total fill height, but sometimes at more than 10% of the fill height. Utilizing the laboratory consolidation testing results, the calculated settlement is anticipated to be on the order of 200 inches. The vast majority of this settlement normally occurs during the construction process. However, we anticipate that some level of crest resurfacing will be required for at least 1-2 years after completion of construction. Per AASHTO, embankment slopes shall meet a Factor of Safety (FOS) of 1.50 or greater for overall stability for long term loading condition, and 1.3 for short term loading condition. Slope stability analyses were performed for WRDA for both total stress condition (short term) and effective stress condition (long term) utilizing the limit equilibrium method that satisfies force and moment equilibrium to compute the critical Factor of Safety (FOS). Soil strength parameters used in stability analyses were estimated based on our subsurface and laboratory results. Calculated results indicate a global FOS of approximately 1.3 for short term loading condition, and 2.3 for long term loading condition. 7.2 Bridge at Stream Crossing No. 1 Based upon the provided Plans dated August 25, 2021, an arch bridge is proposed to cross the stream along the Main Haul Road near Station 13+00 to 14+30. The proposed bottom of footing will be at 780 feet, approximately. Weathered rock was encountered at an approximate elevation of 755 feet on the west side of the stream, and at 777 feet on the east side of the stream. Based upon our previous experience on similar projects within Gaston County, footing on steel HP piles would be a cost-effective option 13 FN Piedmont Lithium I Geotechnical Engineering Report Engineering Evaluations and Recommendations for the footings on the west side of the stream. For a typical HP12x53 pile seated on weathered rock, an allowable pile capacity of 100 tons is anticipated based on a factor of safety of 2. Average HP pile length is on the order of 30 feet. Additional pile capacity may be obtained by utilizing larger steel piles. Settlements of the steel HP piles in weathered rock should be on the order of/2-inch or less. Another option is to use micropiles, which are small diameter(typically less than 12 inches), drilled and grouted non-displacement piles that are typically reinforced. Micropiles should be extended through alluvial soils and embedded into weathered rock. We recommend the micropiles have a minimum diameter of 7 inches and they be socketed a minimum of 10 feet into weathered rock and designed with an allowable pile capacity of 100 kips. Allowable bond strengths of 40 psi (pounds per square inch) may be used for weathered rock. Average micropile length is on the order of 35 feet. Additional pile capacity may be obtained by utilizing larger diameter micropiles and/or longer socket lengths. Settlements of the micropiles in weathered rock should be on the order of/2-inch or less. The minimum center-to center spacing for piles shall be three times their diameter. No reductions of the individual pile axial capacities will be required if piles are spaced center-to-center at three times their diameter or greater. Based upon criteria defined by AASHTO, no reductions of the front row pile lateral capacities will be required if piles are spaced center-to-center at five times their diameter or greater, however, 80% of the lateral capacity shall be used for spacings of three times the diameter. For the back row pile, 70% of the lateral capacities will be required if piles are spaced center-to-center at five times their diameter or greater, and 30% of the lateral capacity shall be used for spacings of three times the diameter. It should be noted that boulders have been encountered at shallow depths at some of the borings and are anticipated to be present at other locations. Therefore, predrilling is anticipated for the installation of steel HP piles. On the east side of the stream, weathered rock is present at depths approximately 3 feet below the proposed bottom of footing. We recommend undercutting the soils to weathered rock and backfilling with flowable fill. Then spread footings can be designed using allowable bearing pressures of 8,000 pounds per square foot (psf). 7.3 Whiteside Road Tunnel Based upon the provided Plans dated August 25, 2021, an ellipse tunnel with an approximate 45.5-foot span and 28-foot rise is proposed along Whitesides Road to cross underneath the Main Haul Road near Station 35+30. The existing grade is approximately 844 feet, and the proposed Haul Road grade is approximately 872 feet. Therefore, up to 28 feet of fill is anticipated to be placed. Residual soils were encountered near existing ground surface and extend to a depth of approximately 37 feet. These soils were underlain by weathered rock and competent rock. Most residual soils were compressible sandy silts with SPT N-values ranging from 4 to 6. 14 FN Piedmont Lithium I Geotechnical Engineering Report Engineering Evaluations and Recommendations HDR performed settlement analyses utilizing elastic and consolidation methods. Parameters for the settlement analyses were obtained from the consolidation testing as well as interpretation from SPT borings and laboratory test results. As described in Section 7.1, settlement of new fills is largely unavoidable regardless of the degree of compaction employed by the Contractor. Typically, we have observed properly compacted fills to settle between 2-6% of the total fill height, but sometimes settlement could be more than 10% of the fill height. Utilizing the laboratory consolidation testing results, the calculated settlement is anticipated to be on the order of 12 inches. The vast majority of this settlement normally occurs during the construction process. The Contractor should monitor settlement during and after fill replacement. Pavement should not be placed until the monitored settlement is less than 0.1 inch over a period of four weeks. If the anticipated settlement is excessive, ground improvements will be required to reduce the settlement. Preloading may be the most cost effective for this site and would not require too much time to complete because the laboratory test results indicate sandy silts are fairly drainable. The objective of preloading is to utilize temporary surcharge loads to consolidate the underlying fine grained silt layer. Preloading may be achieved by placing soil embankment, rockpiles, or concrete blocks that can result in a load equivalent to or greater than the completed structure. Once the settlement exceeds the predicted final settlement or the monitored settlement is less than 0.1 inch over a period of four weeks, the temporary surcharge can be removed. Another option is to use a grid of Rammed Aggregate Piers (RAP), provided by Geopier. Depending on the subsurface conditions, the Geopier system used for a site may consist of either the open-borehole Geopier method, or the impact-displacement Geopier method. For this project, the impact displacement method is considered to be more feasible. The impact-displacement Geopier element is a very stiff compacted aggregate pier created to the full design depth by pushing a special impact apparatus with a relatively large static force augmented by dynamic vertical loading. The hollow-shaft mandrel, filled with open-graded stone, is incrementally raised, permitting the aggregate to be released into the cavity, and then lowered by pushing, ramming or vibrating to densify the aggregate and push it laterally into the adjacent soil. The cycle of raising and lowering the mandrel and impact head is repeated to the ground surface. The final product is a densified aggregate pier of predictable diameter encased in densified and laterally pre-stressed soil. During installation, the hammers that produce the ramming action operate at ranges of 2,000 to 2,400 cycles per minute. These high frequency vibration levels are higher than most other construction activities resulting in a large amount of damping within the reinforced soils at the project site. In the United States, high frequency vibrations levels less than two in/sec at existing building locations are generally considered to be acceptable. For RAP, the peak particle velocities are less than two in/sec at distances on the order of 10 to 15 feet from the pier installation location. Considering that the RAP will generally be located at distances greater than 15 feet from existing structures, construction induced vibration is not anticipated; however, vibration monitoring of adjacent structures should be performed. It should be noted that the installation of RAP will 15 FN Piedmont Lithium I Geotechnical Engineering Report Engineering Evaluations and Recommendations displace soils and may impact utilities located within 3 feet of the RAP. Therefore, existing utility pipes should be exposed prior to RAP installation. RAPs are to be designed and constructed by a Specialty Contractor. Typical RAP construction consists of 24- to 30-inch diameter piers with 3- to 12-foot spacing extending 10 feet beyond the footprint of the structure. RAPs should be extended through the compressible soils to bear on competent residual soils or weathered rock. The estimated capacity for a 20- to 30-foot long RAP is approximately 40 to 50 kips, and the typical total settlement for the RAP system is estimated to be 1 inch or less. The RAP should be designed in proportion to the proposed footing dimensions, anticipated loads, and tolerable settlements. Following RAP installation, proofrolling should also be performed. The actual number, capacity, spacing, and penetration depth, as well as allowable bearing pressure and settlement, should be provided by the Geopier Contractor. It is recommended that a full-scale Modulus Load Test be provided to verify the design capacity. The load test would provide a conservative measure of the stiffness of the element and provide quality control guidelines for the installation procedures. We recommend that HDR be retained to review the design documents and installation plan and monitor the installation. As an alternative to the above-proposed RAP system, stone column installation may also be considered. Stone columns are installed with similar techniques to the RAP, with the exception that water jetting is required. The design and construction of the stone columns should be in accordance with the RAP criteria described above. 7.4 Bridge at Stream Crossing No. 2 Based upon the provided Plans dated August 25, 2021, an arch bridge is proposed to cross the stream along the South Pit Haul Road near Station 13+40 to 14+00. The proposed bottom of footing elevation is approximately 757 feet. Weathered rock was encountered from approximately 717 to 738 feet on the west side of the stream. On the east side, large boulders were encountered and caused tricone refusal at shallow depths after six attempts. Similar to the bridge at Stream Crossing No. 1, footing on steel HP piles would be a cost-effective option for the footings. For a typical HP12x53 pile seated on weathered rock, an allowable pile capacity of 100 tons is anticipated based on a factor of safety of 2. Average HP pile length is on the order of 35 feet. Additional pile capacity may be obtained by utilizing larger steel piles. Settlements of the steel HP piles in weathered rock should be on the order of/2-inch or less. Another option is to use micropiles extended through the alluvial soils and embedded into weathered rock. We recommend the micropiles have a minimum diameter of 7 inches, be socketed a minimum of 10 feet into weathered rock, and designed with an allowable pile capacity of 100 kips. Allowable bond strengths of 40 psi may be used for weathered rock. Average micropile length is on the order of 40 feet. Additional pile capacity may be obtained by utilizing larger diameter micropiles and/or longer socket lengths. Settlement of the micropiles in weathered rock should be on the order of/2-inch or less. 16 FN Piedmont Lithium I Geotechnical Engineering Report Engineering Evaluations and Recommendations Group effects for pile axial and lateral capacity are in accordance with the criteria defined in Section 7.2 above. It should be noted that boulders have been encountered at shallow depths at the borings and are anticipated to be present at other locations. Therefore, predrilling is anticipated for the installation of steel HP piles. 7.5 Haul Roads Based upon the provided Plans dated August 25, 2021, a few haul roads (Main Haul Road, North Pit Haul Road, South Pit Haul Road, etc.)will be constructed throughout the site to facilitate mining activities. Most haul roads will be constructed on proposed embankments. Based upon our investigation, most residual soils consist of micaceous silts and silty sands. These soil types can produce excessive deflection, rutting, and/or reduced resilient modulus if compacted at moisture contents exceeding optimum moisture conditions. Therefore, compaction moisture should be closely monitored during placement and compaction of silt fills. Micaceous silts are best compacted by penetration-type compaction equipment (sheepfoot rollers) operating at slow speeds. Vibratory and pneumatic (rubber-tired) compaction equipment should not be utilized. Compactive effort is best achieved by making more passes with a lighter roller than making fewer passes with a heavy roller. Embankment fill should be placed in loose eight-inch lifts and compacted to 95 percent of Standard Proctor dry density at (±) 2 percent of optimum moisture conditions, as determined by ASTM D-698, except the top 8 inches which should be compacted to 100 percent of maximum density. Adequate drainage is one of the most critical variables in both the life and performance of the road. The necessity of maintaining adequate drainage is heightened considering that most soils at the site are micaceous silts and silty sands, which are prone to soften upon water infiltration. Haul road surface should be designed and installed such that positive drainage is maintained away from the road surface. Following the above recommendations, a California Bearing Ratio (CBR) value of 5 may be used for the haul road pavement section design. 7.6 Structural Fill Material Existing non-highly plastic on-site soils may be used as structural fill provided these soils are free of organic material and within the specified optimum moisture contents. It should be noted that based upon current moisture levels, some the existing site soils are anticipated to be wetter than optimum moisture conditions. Therefore, fill placement and compaction efforts should be conducted in the drier months of the year and scarifying to sufficiently dry the soils should be anticipated. Highly plastic soils (i.e. plasticity indices greater than 25) should not be used as structural fill within 3 feet of subgrade levels due to their shrink/swell potential. These soils may be used in non-structural or landscaped areas. 17 FN Piedmont Lithium I Geotechnical Engineering Report Engineering Evaluations and Recommendations Off-site structural fill materials should be free of organic material, have low to medium plasticity (i.e. plasticity indices less than 25) and a particle size of less than 3 inches. Samples of proposed structural fill materials should be tested for compliance with the above criteria prior to use on-site. All structural fill material should be placed and compacted as described in the section below. 7.7 Site Preparation and Earthwork Initial site preparation should include the following: • Stripping and grubbing of all organic material within proposed construction limits. Topsoil and rootmat on the order of 3 to 6 inches is anticipated. • Subgrades in areas designated to receive fill should be proofrolled to identify zones of instability. Proofrolling should be accomplished using a fully loaded tandem axle dump truck. Areas exhibiting instability should be evaluated by a geotechnical engineer or their qualified representative to determine extent of repair. Following proofrolling, the subgrade areas should be compacted to a minimum depth of 6 inches in accordance with the criteria provided below. • Undercut material, if warranted by the geotechnical engineer, should be replaced with structural fill compacted to at least 95 percent of the soil's maximum dry density as determined by the Standard Proctor method, ASTM D-698. Following the above site preparation recommendations, structural fill and backfilled material should be placed in loose eight-inch lifts and compacted to 95 percent of Standard Proctor dry density at (±) 2 percent of optimum moisture conditions as determined by ASTM D-698. Field density tests should be performed on each lift of fill placed to verify compliance with compaction specifications. Existing on-site soils may be reused as structural fill provided these soils are free of organic material, debris, and are not highly plastic. 7.8 Temporary Excavation and Support Temporary excavations are anticipated for the construction of the foundations and utilities at the site. Excavations deeper than four feet must conform to applicable sections of the Construction Industry Occupational Safety and Health Administration (OSHA) Standards (29CFR1926). In general, compliance will require either sloping back excavations or the use of temporary shoring. If sloping of the excavations is used, slopes should be no steeper than 2:1 (H:V) as discussed below. The referenced (OSHA) standard should be reviewed for requirements regarding use of sloping. It is the Contractor's responsibility to design and construct stable, temporary excavations as part of their safety procedure in accordance with local, state, and federal safety regulations. HDR does not assume responsibility for construction safety or the Contractor's or other party's compliance with applicable safety or other regulations. Provided that the entire excavation is dewatered a minimum of 1 foot below the bottom of the deepest excavation point, and sufficient separation from existing slopes or traffic exists, sloping of the temporary excavations may be performed as described above. Higher groundwater levels or standing water in the excavation may result in unstable slopes. In areas where sufficient separation from existing slopes or traffic does not exist, shoring and/or bracing will be necessary. Based upon the results of the test borings, it is anticipated that site 18 FN Piedmont Lithium I Geotechnical Engineering Report Limitations soils may be retained utilizing conventional shoring techniques such as sheet piles, timber pile and lagging walls or soil nail walls. Shoring should be designed to resist lateral earth pressures from the existing soils and include hydrostatic pressure to account for rises in groundwater levels and/or water infiltrating the retained soils. Once plans are available, HDR should be consulted to review the temporary excavations and shoring designs to ensure they are consistent with the recommendations presented in our report. Excavated soils may be used as backfill provided these soils are free of organic material and within the specified optimum moisture contents. Backfill should be placed and compacted as described in Sections 7.6 and 7.7 above. In addition, it should also be noted that site grades should be designed to provide positive surface drainage away from the proposed excavation. 7.9 Groundwater Control and Dewatering Groundwater levels were measured throughout the site at depths ranging from approximately 11 to 50 feet below ground surface (elevations of 806 to 857 feet). Dewatering of excavations is anticipated at some locations. Water levels should be maintained a minimum of 1 foot below the bottom of proposed excavations at all times. These drawdown levels should be maintained through fill placement and foundation construction. In addition, surface water controls may also be required to prevent saturation and flooding of compacted fills. Surface water controls will need to be designed to collect and drain water from heavy rainfall and/or flooding and may need to include positive draining site grades, sump pumps, gravel lined trenches and other measures. In shallow excavation areas (i.e., 8 feet or less) a gravity drainage system, sump pump, or other conventional dewatering procedure may be used for groundwater control. However, in areas where deeper excavations are planned, dewatering systems consisting of deep wells or well points may be required to properly dewater the site due to the higher water levels. A specialty dewatering contractor should be retained with previous experience in dewatering applications adjacent to structures and should provide alternate methods for reducing drawdown following excavation such as: staged dewatering systems, groundwater recharge, reducing flows from critical areas, etc. 8.0 Limitations This report has been prepared for the exclusive use of PLCI in accordance with generally accepted engineering practices for specific application to this project. Any construction recommendations, wetland, environmental, or contaminant assessment efforts are beyond the scope of this geotechnical exploration; and therefore, those issues are not addressed in this report. No other warranty, expressed or implied, is made. These interpretations and conclusions do not reflect variations in subsurface conditions that could exist intermediate of the test locations or in unexplored areas of the project site. Should such variations become apparent during construction, HDR reserves the right to re-evaluate these interpretations and conclusions based 19 FN Piedmont Lithium I Geotechnical Engineering Report Limitations upon observations of the conditions. In the event changes are made in the proposed construction plans, the information presented in this report shall not be considered valid unless reviewed by HDR and conclusions of this report modified or verified in writing. 20 APPENDIX A: Subsurface Exploration Data Page intentionally left blank. ❑ D 0 ❑❑8 a o \� o WETLAND AREA \ - 0' C3 0 0.06 ACRES 300'SETBACK ° SCREENING BERM r o p t, � I � I-r f �, t; � € � PC29 0 PC30 PC32 >* _ f Gr a - € f — SOLAR FARM �„ ,* F - �. H - o J LANT AREA ENTRANCE Pc 2 C PC8C51 PC96 y ° CONCENTRATE PLANT AND PC52 f4 Q INDUSTRIAL MINERALS PLANT PC79 SEE APPENDIX B ��� NAD-83 Q ♦ o ° s0 NC-SPCS A � LANT AREA ENTRANCE" PC53 'iqA� uj (gipLANT it o 0 ROM PAD PC81 -- ENTRANCE \ S B '/~ � �� DELINEATED WETLAND_:; ENCE 6 FEET HIGH fHIUM HYDROXIDE CONVERSION PLAN . 'tom , J � � I O SEE APPENDIX C / '' ` WATER INTAKE 4 (final alignment to be h q 1p determined) y �pO • Cy NEAREST OCCUPIEgG95 BERM FOR RCN PAD \ 4 PC14 -�6'L I., � PC78 �`• �� DWELLING I PC45 y� PC80 / �� EPHZIBAH CHURCH RD. 1,o29 ft. J. ,P�94 CLOSED i 1 ,n � I PC44 /) jQg�WETLAND A. 1 �/ • 'F 870.0 'UD-4 -PC86 -PC54 I 1 0.11 ACRES Pc7 =`.ems- ,r. �.� / NORTH PIT r300'SETBACK px -STREAM CROSSING NO. 1 '. ryo� '� -PC55 SEE APPENDIX D 100'SETBACK y CONCENTRATE PLANT/CONVERSION PLANT /40 S \k, PC92 / o CONDITIONAL SETBACK(TYP) \ EXISTING CEMETERY SITE-,-----,--, ITE PC43 7J CONVEYOR ACCESS ROAD NO.1 %'• ,� RC 1_ 7 PLANT PC87 OPC93 / > `^ MAINTENANCE YARD ^� �.\' TRANCE,# P 6 NORTH Pn CONVEYOR ACCE66r ` 1 50'CEMETERY SITE BUFFER \ V ROAD P% C _ _5 �� NEAREST OC UPIED ,O(� PC46 RC21 t,8NHAULROAD oy�\ qC DWELLIN EMULSION STORAGE AND �. / — k ° 385 ft. ° BULK TRUCK PARKING r PC59- GT21_3Q, PC91 AREA ACCESS D r�A Pc90 f3T21zo� -- � l� -\ % \A, .sue PC88 LOCKING GATE �� �- z5too _ 1 O C97 GT21 2 —� o0 PC11 - P yr~ 0 1 6 - a RC21_3 G ' \ 100'SETBACK //� PO. PC9 \ � , ti PC PC10 '� � t /x 84 RC�'1_1 PC100 , . NORTH PIT HAUL ROAD l i 100 YEAR FLOOD ZONE ��-\ - "/ - o WETLAND AREA �'�_ -- - _ 1_ _ -------, `, B o WASTE ROCK PILE ��0,. - !'� \.•�" -� GT21 45 Y WHITESIDES ROAD CROSSING'' RC85 ,, ; oo �`\ 98 / { I LINE(TYP) 1.13 ACRES PC$ � ro. ,: ,y SEE APPENDIX B �- ✓ -� �'. y, 7 ', — rJ8 i-PC89 WETLAND AREA7 �� `. •�`� /1 /.' _ I PC62 - %� B o I 100 YEAR FLOOD ZONE P^7., I \` �,`• .i $ , I I t 1.53 ACRES _ `` — 2 I O \PC9 li i 1 2 PC57 9 i I6T21_27 131 ` �--- CB i � _ 60 PC63 s ;` �\ _ - ' �uD-5 � T2 _ q., -' �\ o �r WEST PIT U D 3 G 2 10 T21`2 ``c5 A �,� , ...�, SEE APPENDIX D ��1�� GT21 1 ? "v �. 6eeHndl6�Fee1 Dof3 r- C61 e t t EMULSION STORAGE �����` � ° �� 1 ° ° GT21 31 i �� AND BULK TRUCK PARKING `.,_� -.� TOPSOIL ` �� AREA SEE APPENDIX B 4i o '..•�./;' �� �� MAGAZINE LOCATION 5$o 1 ����� /' / SEE APPENDIX B _ � `� � �� / • ��' TORAGE PILE � PC3 47 �. / ' l PC101 PC2 � ��• .. CONCENTRATE PLANT/CONVERSION PLANT PC PC75 Y4 ��°, GT2,1 2H I �� I CONVEYOR ACCESS ROAD NO.2 — /� 21, 9 " / ` It SOUTH PIT OROAD RACOE66 ' _ r �•I % I 1 ROAD Y. �\ k \.... A O PC4 boa _. r G� �h g" MAIN HAUL ROAD _ Q- 1090`Q X 2 _ 65 soloo - % GT 1 1�; O000 O PC48 PC7 �,'f21 _.$ i �'- — ",.._ - 7 ;PC -- - GT21F_22a�t - i �, ° / e �xo B c I v • / t ;PC67 � �' �. ' , R Z GT21_7 %/ ; \ G �21_11 1' .' \ , * ; I\C EAST PIT AN TOPSOIL PIIF I O �/ i ` `!� GT21 I °�Po HAUL ROADI6HEET2ILIIIE I O �! �. 'C66 ,& a SOUTH PIT HAUL ROAD 121 RC21 9 Cl 15 PC73 Ch.T21 20 STR M CROSSING NO. ' _ PC103 — ; i � RC114 #ZC21 10 m -PC70ii GT21►_19 G1�1_13 318' vV EXISTING STREAM CROSSING WASTE ROCK PILE O o ENTRANCE / ADJACENT PROPERTY OWNERS PC71 NEAREST CCUPIED DWELLING �� GT21 17 / ��72 � 318 ft. � PC113 / 'LOCKING GATE `• �'�'' SOUTH PIT 1 SEE APPENDIX D w -, 3 0 00 J Z Z o N O H Z PC68 0 0 3 C \ 0 0 O 0 ! C 0 PC105 c� c� OD a w n zF- V) PROPOSED BERM GTA_2@ C3 �w v p ° Q EAST PIT 3 � J � Z SEE APPENDIX D W U � J P[=07 0 o c� o � a LL- 0 0 � -- o I/ 0 0 i �E jQ1SILs;=cG °o z Z — J o 6p MINE PIT CONSTRUCTION SEQUENCE Q W SEE NOTES PC112 GT21_I�,qs,/ Z o �csRo = 0- z PC108 ~ Q J o I" clog V O W z z a 0 o ASTINGS RD. F_ � CLOSED _ = Z W PC11� LOCKING GATE o F- �— Q 1 _ LEGEND OU a BORING SAMPLE LOCATION Z Z H 2 O o AERIAL TOPOGRAPHY = 2 FT. CONTOURS Q HEPHZIBAH CHURCH RD. AERIAL MAPPING DATED JANUARY 2021 LLI Q CLOSED (PRIVATE AND EMS ° o AND PROVIDED BY PIEDMONT LITHIUM CAROLINAS, iINC. 0 o u SOUTHERN ENTRANCE) PC110 0 LOCKING GATE O NEAREST OCCUPIED o AERIAL VIEW DWELLING 378 ft. 0 0 0 0 500 1000 1500 SHEET NUMBER 20F2 SCALE 1"=500' Z � 2 H 1100 CRE T Fl PHA.I;F - 1100 O J PROPOSED GRADE �y'` PHASE II ?j Qw H i 3�.w 20 ft. Bench (typically Uj i U IUm � � I� IU)U 1000 I I� 1'If1000 Z PROPOSED GRAD U PHASE I ROADBERM �� ' I 0 Iz joy z 1 aio �' j� I j0 GT21 13 1" Q ROAD DITCH — 10 900 I `L 900 GT 1 28 CONCENTRATE PLANT/CONVERSION PLANT GT21 11 2 DIVERSION U CONVEYOR ACCESS ROAD NO. 1 I GT21 2 — — 7 DITCH DA-19 Iw 1522 mill823 IU w 10 9 7 EXISTING GRADE 11 1 7 1 3 I z g 5 ' 101 6 7 1610 9 7 5 50/0.1 9 6 7 9 5 4 3 19 5 50/0.1 50/0.3 2413 R 17 19 5 6 12 6 DIVERSION DITCH BERM #19 800 50/0.1 7t I 1 800 50/0.1 ROA DITCH 50/0.0 R I M/_-, 8 1 �I 50/0.2 8 1 Z I 50/0.4 8 i < I 50/0.3 42 50/0.4 39 0 50/0.1 9 I I 50/0.5 56 56 50/0.2 4 42 i m I o z 50/0.4 50/0.3 i 50/0.2 50/0.2 700 i R 50/0. 700 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 0 0 z WASTE PILE CROSS SECTION A—A' SCALE: 1" = 100' VE = 1:2 J) z N z p O J = NN O H U LLI V) \ N U U w 000 Q 3 O z W W U O U U LJ J � Z v, a w i a O J w i 2 Q U 0 U 0 (n i li J Q U Q ~ Z Z W J � Q W Z O z Q P J v w W ~ � W_ LEGEND Q v O Cl) > Ell USCS Silt Ell USCS Silty Sand ®Weathered Rock ®USCS Elastic Silt ® Cn ClayS Low Plasticity Z O W USCS High Plasticity ®Clay f-i O � Z HIx —10 a. a U Z � O z0 O 0 W Q F- a. id cn a I hereby certify that this document was prepared by me or under my direct personal supervision and is correct to the best of my PROFILE VIEW knowledge and belief and that I am a duly licensed Professional Engineer under the laws of the State of North Carolina. 0 100 200 300 SHEET NUMBER (Signature) Date: 3 OF 34 SCALE 1 "=100' Z � 2 H of 0 W ROAD DITCH 1100 ROAD BERM _ jQgQ Q 1100 CREST EL. PHASE 1 = 1068.0 20 ft. Bench (typical) PROPOSED GRADE PHASE II '� 1000 1000 A PROPOSED GRADE ? PHASEI :: 900 (� ��� 900 1 18 GT21 _28 106 GT21 24 11 9 10 8 10 8 14 `'7 6 7 EXISTING GRADE 7 GT21 9dT21 10 11 3 4 6 8 6 8 11 4 1114 IY I 7 7 5 8 8 5 9 24 5 4 o g 9 31 3 0 j 4 14 7 4 13 4 Ln 9 6 51 jwa j� 1719 6 4 6 1 A— z800 10 50/0.1 R I r —j 5 /0.1 6 1 800 8 50/0.0 I<� jm 50/0.0 50/01 4 61011I—w IU R 7 8I�0 I W 6 1 4 38 I w Q j 1 11 1 L5e60 3 50/0.4 36 I I Q 1 16 58 50/0.0 R I— j 191 50/0.4 50/0.4 j j U 3 50/0.3 50/0.3 3 � °13 50/0.2 50/0.0 R 4540 700 I z 38 66 700 I j 38 69 I 50/0.4 I co 423 IC0 j 50/0.4 j z 50/0.3 I Q I j R m j Iw z o 0 I I I Iw W U \ O2 J W C0 \ \ (n U7 U w � 000 Q 3 600 _ 600 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 0 z 0 0 � .. w w U 0 U U LJ Ld-1 � Z WASTE PILE CROSS SECTION B-B' w Q � � U 0 SCALE: 1" = 100' VE = 1:2 J Q U Q ~ Z Z W J � Q W Z O z Q P J v w W ~ � W_ LEGEND Q v O Cl) > USCS Silt ®USCS Silty Sand ®Weathered Rock ®USCS Elastic Silt ® Cn ClayS Low Plasticity Z O W USCS High Plasticity J Clay = ~ W O H D J Ix J O a a U Z � O z0 O 0 LU W Q EL a I hereby certify that this document was prepared by me or under my direct personal supervision and is correct to the best of my PROFILE VIEW knowledge and belief and that I am a duly licensed Professional Engineer under the laws of the State of North Carolina. 0 100 200 300 SHEET NUMBER (Signature) Date: 3 OF 34 SCALE 1 "=100' Page intentionally left blank. SOIL CLASSIFICATION CHART MAJOR DIVISIONS SYMBOLS TYPICAL GRAPH LETTER DESCRIPTIONS CLEAN O O CD WELL-GRADED GRAVELS,GRAVEL- GRAVEL GRAVELS a O 0 _ GW SAND MIXTURES, LITTLE OR NO FINES AND O _ O - GRAVELLY �- - SOILS � POORLY-GRADED GRAVELS, (LITTLE OR NO FINES) • i - GP GRAVEL-SAND MIXTURES, LITTLE OR NO FINES COARSE GRAINED GRAVELS WITH SILTY GRAVELS,GRAVEL-SAND- SOILS MORE THAN 50% FINES GM SILT MIXTURES OF COARSE FRACTION RETAINED ON NO. 4 SIEVE (APPRECIABLE GC CLAYEY GRAVELS,GRAVEL-SAND- AMOUNT OF FINES) CLAY MIXTURES CLEAN SANDS SW WELL-GRADED SANDS,GRAVELLY MORE THAN 50% SAND . . . . SANDS,LITTLE OR NO FINES OF MATERIAL IS AND LARGER THAN SANDY POORLY-GRADED SANDS, NO.200 SIEVE SOILS ' SIZE (LITTLE OR NO FINES) . . . SP GRAVELLY SAND,LITTLE OR NO • • • • FINES SANDS WITH SILTY SANDS,SAND-SILT MORE THAN 50% FINES SM MIXTURES OF COARSE FRACTION PASSING ON NO. 4 SIEVE (APPRECIABLE SC CLAYEY SANDS,SAND-CLAY AMOUNT OF FINES) �7 MIXTURES INORGANIC SILTS AND VERY FINE ML SANDS,ROCK FLOUR,SILTY OR CLAYEY FINE SANDS OR CLAYEY SILTS WITH SLIGHT PLASTICITY SILTS INORGANIC CLAYS OF LOW TO FINE AND LIQUID LIMIT MEDIUM PLASTICITY,GRAVELLY GRAINED LESS THAN 50 CL CLAYS,SANDY CLAYS,SILTY CLAYS, CLAYS LEAN CLAYS SOILS OL ORGANIC SILTS AND ORGANIC SILTY CLAYS OF LOW PLASTICITY MORE THAN 50% INORGANIC SILTS,MICACEOUS OR OF MATERIAL IS MH DIATOMACEOUS FINE SAND OR SMALLER THAN SILTY SOILS NO.200 SIEVE SIZE SILTS LIQUID LIMIT INORGANIC CLAYS OF HIGH AND GREATER THAN50 CH PLASTICITY CLAYS ORGANIC CLAYS OF MEDIUM TO OH HIGH PLASTICITY,ORGANIC SILTS HIGHLY ORGANIC SOILS PT PEAT, HUMUS,SWAMP SOILS WITH HIGH ORGANIC CONTENTS NOTE: DUAL SYMBOLS ARE USED TO INDICATE BORDERLINE SOIL CLASSIFICATIONS KEY TO SOIL CLASSIFICATION Correlation of Penetration Resistance with Relative Density and Consistency Sands and Gravels Silts and Clays No. of Relative No. of Relative Blows,N Densi Blows,N Densi 0 - 4 Very loose 0 - 2 Very soft 5 - l 0 Loose 3 - 4 Soft 11 - 30 Medium dense 5 - 8 Firm 31 - 50 Dense 9 - 15 Stiff Over 50 Very dense 16 -30 Very stiff 31 - 50 Hard Over 50 Very hard Particle Size Identification (Unified Classification System) Boulders: Diameter exceeds 8 inches Cobbles: 3 to 8 inches diameter Gravel: Coarse- 3/4 to 3 inches diameter Fine -4.76 mm to 3/4 inch diameter Sand: Coarse-2.0 mm to 4.76 mm diameter Medium-0.42 mm to 2.0 mm diameter Fine -0.074 mm to 0.42 mm diameter Silt and Clay: Less than 0.07 mm(particles cannot be seen with naked eye) Modifiers The modifiers provide our estimate of the amount of silt, clay or sand size particles in the soil sample. Approximate Field Moisture Content Modifiers Description Saturated: Usually liquid; very wet, usually <_ 5%: Trace from below the groundwater table 5%to 12%: Slightly silty, slightly clayey, Wet: Semisolid; requires drying to attain slightly sandy optimum moisture 12%to 30%: Silty,clayey,sandy Moist: Solid; at or near optimum moisture 30%to 50%: Very silty,very clayey,very Dry: Requires additional water to attain sandy optimum moisture F)� — PAGE: 1 of 2 BORING NO.: GT21 1 JOB NO.: 10292406 DATE: 9/27/2021-9/27/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604982.43000 EASTING: 1311200.04000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 856.0 ft COMPLETION DEPTH: 88.9 WATER TABLE IMMEDIATE: WATER TABLE 24hr:50.0 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN o�iz �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z x 2 O W U U S Depth Elevation !n U U) Red and brown,elastic SILT(MH),very 7-9 11 stiff,moist(RESIDUUM) (20) 3.5 _ 852.5 Brown,white,and tan,silty SAND(SM), 6-4-4(8) e.o x loose,moist 1-3-2(5) 8.5 ______ ___ 847.5 Orange,tan,and black,sandy SILT(ML), 2-3-3(6) 10.0 x firm,wet 2-2-4(6) 15.0 18.5 ______________ 837.5 Orange,tan,and white,silty SAND(SM), 2-2-4(6) 20.o micaceous,loose to very dense,wet 2-3-3(6) 25.0 2-3-4(7) 30.0 2-2-4(6) 35.0 2-3-6(9) 40.0 2-4-7 45.0 x (11) 4-5-9 F)� — PAGE: 2 of 2 BORING NO.: GT21 1 JOB NO.: 10292406 DATE: 9/27/2021-9/27/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604982.43000 EASTING: 1311200.04000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 856.0 ft COMPLETION DEPTH: 88.9 WATER TABLE IMMEDIATE: WATER TABLE 24hr:50.0 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) 5-6-9 55.0 x (15) 11-16-15 60.0 x (31) 8-19-26 65.0 x (45) 12-17-25 70.0 x (42) 17-24-45 75.0 (69) n.o 779.0 Gray,brown,WEATHERED ROCK(WR) 25-49- 80.0 50/0.3 (50/0.3) 50/0.4 85.0 (50/0.4) 88.9 767.1 50/0.4 90.0 Boring Terminated at 88.9'in (50/0.4) WEATHERED ROCK(WR) 95.0 Rig chatter encountered at 77.0 ft. — PAGE: 1 of 1 F)� BORING NO.: GT21 2 JOB NO.: 10292406 DATE: 9/29/2021-9/29/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotaryw/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605193.33000 EASTING: 1311915.52000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 841.7 ft COMPLETION DEPTH: 24.3 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo �= U o T B P DESCRIPTION OF MATERIALS m J U)a w(D 0-Z'a H O O U)Z dN o�Z �Q— aiz m m L 0 0 (ft.) L E C1 g o 8-1 Z S O W U U S Depth Elevation U U) Red and brown,elastic SILT(MH),very stiff,moist(RESIDUUM) 6-8-9 (17) 3.5 ----------------- 838.2 Red,black,and yellow,silty SAND(SM), 6-5-5 5.0 micaceous,loose,wet (10) 2-5-4(9) 2-2-4(6) 10.0 13.0 828.7 Gray and brown,WEATHERED ROCK 50/0.1 15.0 - (WR) (50/0.1) 50/0.1 20.0  (50/0.1) 24 3 817.4 41-50/0.3 25.0 Boring Terminated at 24.3'in (50/0.3) WEATHERED ROCK(WR) 30.0 35.0 40.0 45.0 F)� — PAGE: 1 of 2 BORING NO.: GT21 4 JOB NO.: 10292406 DATE: 10/6/2021-10/7/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605630.42000 EASTING: 1312670.52000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 854.9 ft COMPLETION DEPTH: 67.0 WATER TABLE IMMEDIATE: WATER TABLE 24hr:43.0 ft D S E Y A � — C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 ( ) E to 0 g o o j y0 �� U U ft. L a 0 S Depth Elevation J Z U U) Red and brown,elastic SILT(MH),stiff, moist(RESIDUUM) 8-6-7 (13) 8-5-6 5.0 (11) Orange,purple,and white,silty SAND 2-3-4(7) (SM),loose to very dense,moist to wet 2-4-6 10.0 77 (10) 2-4-7 15.0 x (11) 3-4-6 20.0 x (10) 2-2-4(6) 25.0 2-3-5(8) 30.0 3-3-3(6) 35.0 2-3-5(8) 40.0 3-3-5(8) 45.0 11-22-50 F)� — PAGE: 2 of 2 BORING NO.: GT21 4 JOB NO.: 10292406 DATE: 10/6/2021-10/7/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605630.42000 EASTING: 1312670.52000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 854.9 ft COMPLETION DEPTH: 67.0 WATER TABLE IMMEDIATE: WATER TABLE 24hr:43.0 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z �0 U U S Depth Elevation U U) 12-9-20 55.0 x (29) 57.0 7s7.s Dark gray and white,WEATHERED ROCK (WR) 50/0.2 60.0 (50/0.2) sz.o ----------------- sz.s Gray,tan,and brown,silty SAND(SM), dense,moist to wet(RESIDUUM) 8-17-16 65.0 (33) 66.5 788.4 67.0 Dark gray and white,WEATHERED ROCK 787.s 50/0.0 WR (50/0.0) Tricone refusal at 67.0'on CRYSTALLINE 70.0 ROCK(CR) 75.0 Hard drilling encountered at 66.5 ft. 80.0 85.0 90.0 95.0 F)� — PAGE: 1 of 2 BORING NO.: GT21 7 JOB NO.: 10292406 DATE: 9128/2021-9/28/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604106.52000 EASTING: 1311045.72000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 869.5 ft COMPLETION DEPTH: 98.0 WATER TABLE IMMEDIATE: WATER TABLE 24hr:28.9 ft D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo �= U o T B P DESCRIPTION OF MATERIALS m J H 0 U)Uo w(D 0-Z'a H O O U)Z dN o�Z �Q— aiz m m L 0 0 (ft.) L E C1 g o 8-1 Z 52 O U U S Depth Elevation U U) Red and brown,elastic SILT(MH), 6-10-14 micaceous,very stiff,moist(RESIDUUM) (24) 3.5 ----------------- 666.0 Tan,brown,and orange,silty SAND(SM), 6-6-7 5.0 loose to dense,moist to wet (13) 2-3-5(8) 77 2-3-4(7) 10.0 2-2-4(6) 15.0 2-2-3(5) 20.0 1-3-2(5) 25.0 1-2-2(4) 30.0 2-3-4(7) 35.0 2-4-7 40.0 x (11) 2-4-7 45.0 x (11) 2-5-8 — PAGE: 2 of 2 F)� BORING NO.: GT21 7 JOB NO.: 10292406 DATE: 9128/2021-9/28/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604106.52000 EASTING: 1311045.72000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 869.5 ft COMPLETION DEPTH: 98.0 WATER TABLE IMMEDIATE: WATER TABLE 24hr:28.9 ft D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo U)= U o TB P DESCRIPTION OF MATERIALS m J H 0 U)Uo w(D 0-z'a H O O U)Z dN o�iz �Q— aiz m m L 0 0 (ft.) L E C1 g o ; 5 w 2 O w U U S Depth Elevation U U) 3-6-9 55.0 x (15) 3-6-10 60.0 x (16) 3-10-9 65.0 x (19) 4-7-7 70.0 x (14) 2-2-4(6) 75.0 3-5-6 80.0 x (11) 5-14-20 85.0 x (34) 11-11-18 90.0 77 (29) 92.0 777.5 WEATHERED ROCK(WR), No recovery 50/0.1 95.0 S (50/0.1) 98.0 771.5 Tricone refusal at 98.0'on CRYSTALLINE 50/0.0 ROCK CR (50/0.0) F)� — PAGE: 1 of 2 BORING NO.: GT21 8 JOB NO.: 10292406 DATE: 9/24/2021-9/27/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604278.66000 EASTING: 1311859.89000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 884.9 ft COMPLETION DEPTH: 75.6 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 ( ) E to 0 g o o j y0 �� U U ft. L a 0 S Depth Elevation J Z U U) Red,brown,and tan,elastic SILT(MH)very stiff to stiff,moist(RESIDUUM) 9-8-10 (18) 9-8-9 5.0 (17) 3-4-6 (10) s.s ___ ___ a7s.a 10.0 Tan and red,sandy SILT(ML),firm, moist 2-2-4(6) 12L5 _ _ 871.4 Tan,brown,and orange,silty SAND(SM), 3-4-6 15.0 x micaceous, loose to dense,wet (10) 3-4-6 20.0 x (10) 3-3-5(8) 25.0 2-3-4(7) 30.0 2-3-5(8) 35.0 2-2-4(6) 40.0 2-3-5(8) 45.0 3-5-6 F)� — PAGE: 2 of 2 BORING NO.: GT21 8 JOB NO.: 10292406 DATE: 9/24/2021-9/27/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604278.66000 EASTING: 1311859.89000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 884.9 ft COMPLETION DEPTH: 75.6 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN o�iz �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 O w U U S Depth Elevation U rn 4-5-9 55.0 x (14) 8-10-21 60.0 x (31) 7-10-13 65.0 x (23) 8-11-14 70.0 x (25) 4-7-10 75.0-1 71.0 809.9 (17) 'S6 WEATHERED ROCK WR , No recovery 809.3 50/0.1 Tricone refusal at 75.6'on CRYSTALLINE (50/0.1) ROCK(CR) 50/0.0 (50/0.0) 80.0 Hard drilling encountered at 75.0 ft. 85.0 90.0 95.0 F)� — PAGE: 1 of 4 BORING NO.: GT21 9 JOB NO.: 10292406 DATE: 8/20/2021-8/25/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604620.88000 EASTING: 1312950.33000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 834.2 ft COMPLETION DEPTH: 174.3 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 17.0 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zo_= zo �= U o TB P DESCRIPTION OF MATERIALS m J �Uo w(D d Z'a � H O O U)Z dN o�iz �Q— o W m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) Red and orange,elastic SILT(MH),firm to 2-3-5(8) 77 very stiff,moist(RESIDUUM) 8-11-14 5.0 (25) 6-9-15 (24) 5-5-9 10.0 (14) 2-3-4(7) 15.0 18.5 _ ___ 815.7 Tan,brown,and white,sandy SILT(ML), 2-2-4(6) 20.0 x firm,moist 23.5 _ _ 81C.7 Tan,brown,and white,silty SAND(SM), 2-1-3(4) 25.0 x saprolitic,very loose to very dense,wet 2-3-3(6) 30.0 2-2-3(5) 35.0 2-2-2(4) 40.0 2-2-4(6) 45.0 2-3-4(7) F)� — PAGE: 2 of 4 BORING NO.: GT21 9 JOB NO.: 10292406 DATE: 8/20/2021-8/25/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604620.88000 EASTING: 1312950.33000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 834.2 ft COMPLETION DEPTH: 174.3 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 17.0 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J �a w(D d Z'a � H O O U)Z dN o�iz �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 0 w U U S Depth Elevation U U) 1-3-3(6) 55.0 2-2-4(6) 60.0 3-6-11 65.0 x (17) 2-4-7 70.0 (11) 3-5-7 75.0 (12) 5-8-13 80.0 x (21) 5-7-9 85.0 x (16) 5-9-10 90.0 x (19) 6-8-9 95.0 x (17) 5-9-14 — PAGE: 3 of 4 BORING NO.: GT21 9 JOB NO.: 10292406 DATE: 8/20/2021-8/25/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604620.88000 EASTING: 1312950.33000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 834.2 ft COMPLETION DEPTH: 174.3 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 17.0 ft D S S N w'N A (� Lu H (�j Lu Hw > c o E Y M Hx zw z�x zo CO U 0 T M p DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af H O L O ¢Z dN oc=nw �Q a o W m (ft.) L E 0 a a o j U U S Depth Elevation J Z Cn U C/) 13-17-20 105.0 (37) 4-9-11 110.0 (20) 5-5-8 115.0 (13) 14-21-24 120.0 x (45) 8-15-25 125.0 x (40) 8-18-20 130.0 x (38) 15-27-39 135.0 x (66) 15-25-23 140.0 x (48) 36-34-35 145.0 x (69) 12-17-18 F) -9 PAGE: 4 of 4 l BORING NO.: GT21 JOB NO.: 10292406 DATE: 8/20/2021-8/25/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604620.88000 EASTING: 1312950.33000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 834.2 ft COMPLETION DEPTH: 174.3 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 17.0 ft D S S (n w'1n A Lu H ()j Lu aHw >� c o E Y M ~x zw zOf= zo �_ o T M p DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w� H O L O ¢Z dN oc=nw �Q a o W m (ft.) L E 0 a a o j U U S Depth Elevation J Z CA U C/) 1 s4.0_________________ 680.2 27- 155.0 White,brown,and pink,WEATHERED 50/0.4 ROCK(WR) (50/0.4) s�.o----------------- sn.z Brown and white,silty SAND(SM),dense, wet(RESIDUUM) 10-14-18 160.0 x (32) 7-16-26 165.0 x (42) 169s 664.7 13-33- 170.0 Brown and white,WEATHERED ROCK 50/0.4 (WR) (50/0.4) 174.3 659.9 47-50/0.3 175.0 Boring Terminated at 174.3'in (50/0.3) WEATHERED ROCK(WR) 180.0 185.0 190.0 195.0 — PAGE: 1 of 2 BORING NO.: GT21 10 JOB NO.: 10292406 DATE: 10/26/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604971.39000 EASTING: 1313451.54000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 807.0 ft COMPLETION DEPTH: 49.4 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a aW m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U Cn Dark brown and gray,sandy CLAY(CL), 7-8-10 very stiff to stiff,dry to wet(RESIDUUM) (18) 10-10-13 5.0 (23) 4-5-8 (13) 3-5-8 10.0 (13) 13.5 793.5 Dark brown,sandy SILT(ML),soft to firm, 1-1-2(3) 15.0 wet 2-2-5(7) 20.0 23.5 783.5 White,silty SAND(SM)with rock 4-5-5- 25.0 x fragments,saprolitc,loose to medium (10) dense,wet 9-15-13 30.0 (28) 34.0 773.0 9-50/0.5 35.0 White WEATHERED ROCK(WR) (50/0.5) 40-15- 40.0 50/0.4 (50/0.4) 32-50/0.3 45.0 (50/0.3) 49.4 7s7.s 39-50/0.4 — PAGE: 2 of 2 F)� BORING NO.: GT21 10 JOB NO.: 10292406 DATE: 10/26/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604971.39000 EASTING: 1313451.54000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 807.0 ft COMPLETION DEPTH: 49.4 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D d Z'a w H O O U)Z dN 0 �Q— dW m m L 0 0 E to 0 g o o j w y0 �w U U ft. L a 0 S Depth Elevation J Z U U) Boring Terminated at 49.4'in WEATHERED ROCK(WR) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 90.0 95.0 — PAGE: 1 of 4 F)� BORING NO.: GT21 11 JOB NO.: 10292406 DATE: 10/4/2021-10/5/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County,NC EQUIPMENT: CME55 314425 NORTHING: 604057.20000 EASTING: 1312385.81000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 869.6 ft COMPLETION DEPTH: 158.7 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 13.1 ft D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo �= U o T B P DESCRIPTION OF MATERIALS m J H 0 U)Uo w(D d Z'a H O O U)Z dN o iz �Q— aiz m m L 0 0 (ft.) L E C1 g o Z 52 O U U S Depth Elevation8-1 !n U U) Red and brown,elastic SILT(MH),very 7.10-13 stiff,moist(RESIDUUM) (23) 3. 666.1 Tan,brown,and gray,silty SAND(SM), 15-16-12 5.0 loose to dense,micaceous,moist to wet (28) 4-5-6 (11) 3-4-6 10.0 77 (10) 3-2-5(7) 15.0 2-3-4(7) 20.0 5-5-5 25.0 x (10) 3-7-9 30.0 x (16) 2-3-4(7) 35.0 2-2-3(5) 40.0 6-8-11 45.0 x (19) 2-2-4(6) — PAGE: 2 of 4 F)� BORING NO.: GT21 11 JOB NO.: 10292406 DATE: 10/4/2021-10/5/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County,NC EQUIPMENT: CME55 314425 NORTHING: 604057.20000 EASTING: 1312385.81000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 869.6 ft COMPLETION DEPTH: 158.7 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 13.1 ft D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo U)= U o TB P DESCRIPTION OF MATERIALS m J H 0 U)Uo w(D d z'a H O O U)Z dN o iz �Q— aiz m m L 0 0 (ft.) L E C1 g o ; 5 w 2 O w U U S Depth Elevation U U) 2-2-4(6) 55.0 2-2-3(5) 60.0 2-3-4(7) 65.0 2-3-4(7) 70.0 4-5-8 75.0 x (13) 3-4-8 80.0 x (12) 3-8-13 85.0 x (21) 3-6-10 90.0 x (16) 3-8-11 95.0 x (19) 4-9-26 — PAGE: 3 of 4 F)� BORING NO.: GT21 11 JOB NO.: 10292406 DATE: 10/4/2021-10/5/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County,NC EQUIPMENT: CME55 314425 NORTHING: 604057.20000 EASTING: 1312385.81000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 869.6 ft COMPLETION DEPTH: 158.7 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 13.1 ft D S E Y A � — C9> w � HW >_° o 0 M x zw zwm zo �= U o TB P DESCRIPTION OF MATERIALS m J H 0 U)Uo w(D d Z'a H O O U)Z dN o Z �Q— aiz m m L 0 0 (ft.) L E C1 g o 8-1 Z 52 O U U S Depth Elevation U U) 5-9-14 105.0 x (23) 6-12-19 110.0 x (31) 6-11-20 115.0 x (31) 8-16-23 120.0 x (39) 124.0———— —— L45.6 26-50/0.3 125.0 Tan and white,Weathered Rock(WR) (50/0.3) 127.0 ——— 742.6 Gray and white,silty SAND(SM),dense, wet(RESIDUUM) 10-19-23 130.0 (42) 133.5 736.1 135.0 Light tan,WEATHERED ROCK(WR) 50/0.1 137.0 --- 73z.6 Gray and white,silty SAND(SM),very dense,wet(RESIDUUM) 11-22-34 140.0 (56) 19-22-34 145.0 (56) lazo 722.6 Grey and white,WEATHERED ROCK (WR) 33-50/0.5 — PAGE: 4 of 4 F)l BORING NO.: GT21 11 JOB NO.: 10292406 DATE: 10/4/2021-10/5/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604057.20000 EASTING: 1312385.81000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 869.6 ft COMPLETION DEPTH: 158.7 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 13.1 ft D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w� P _ H O L O ¢Z dN oc=nw �Q a o w m (ft.) L E ct) 0 a a o � U U `S Depth Elevation J Z Cn U C/) 15-27- 155.0 50/0.4 (50/0.4) 158.7 710.9 50/0.2 160.0 Boring Terminated at 158.7'in (50/0.2) WEATHERED ROCK(WR) 165.0 Hard drilling encountered at 147.0 ft. 170.0 175.0 180.0 185.0 190.0 195.0 — PAGE: 1 of 3 F)� BORING NO.: GT21 13 JOB NO.: 10292406 DATE: 8/26/2021-8/27/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603556.12000 EASTING: 1312640.74000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 851.9 ft COMPLETION DEPTH: 143.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 10.9 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J �Uo w(D d Z'a � H O O U)Z dN o�iz �Q— dW m m L 0 0 ( ) E to 0 g o o j y0 �� U U ft. L a 0 S Depth Elevation J Z U U) Red and brown,sandy SILT(MH),soft to stiff,moist(RESIDUUM) 1-1-2(3) 4-7-8 5.0 (15) 5-4-5(9) 8.5 ________ ___ 843.4 Red,orange,and black,elastic SILT(MH), 1-2-3(5) 10.0 firm to soft,wet 15.0 2-1-3(4) 20.0 23.5 _______________ _ 828.4 Tan,orange,and white,silty SAND(SM), 2-2-3(5) 25.0 loose to medium dense,wet 2-2-3(5) 30.0 3-6-5 35.0 x (11) 3-6-6 40.0 x (12) 2-3-3(6) 45.0 2-3-4(7) — PAGE: 2 of 3 F)� BORING NO.: GT21 13 JOB NO.: 10292406 DATE: 8/26/2021-8/27/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603556.12000 EASTING: 1312640.74000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 851.9 ft COMPLETION DEPTH: 143.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 10.9 ft D S E Y A � — C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J �a w(D d Z'a � H O O U)Z dN o�iz �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z �0 W U U S Depth Elevation U U) 3-3-5(8) 55.0 6-9-11 60.0 x (20) 3-8-9 65.0 x (17) 3-4-9 70.0 x (13) 2-3-4(7) 75.0 3-8-12 80.0 (12) sa.o 767.9 18-50/0.2 85.0 White,WEATHERED ROCK(WR) (50/0.2) s7.0 ————————————————— Lo4.s White,silty SAND(SM)with few rock fragments,saprolitic,very dense,moist 19-36-45 90.0 (RESIDUUM) (81) 94.0 757.9 37-50/0.4 95.0 White,WEATHERED ROCK(WR) (50/0.4) 97.o ————————————————— aa.s White and gray,silty SAND(SM)with few rock fragments,saprolitic,very dense, 13-22-56 moist(RESIDUUM) - PAGE: 3 of 3 F)� BORING NO.: GT21 13 JOB NO.: 10292406 DATE: 8/26/2021-8/27/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603556.12000 EASTING: 1312640.74000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 851.9 ft COMPLETION DEPTH: 143.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 10.9 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J �Uo w(D d Z'a � H O O U)Z dN o�iz �Q- dW m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) 103.5 - 748.4 Light tan,WEATHERED ROCK(WR) 50/0.4 105.0 - (50/0.4) 107.0________ ___ 744.9 Brown,tan,and white,silty SAND(SM), medium dense to dense,moist 14-18-21 110.0 x (RESIDUUM) (39) 8-13-16 115.0 x (29) 10-19-26 120.0 x (45) 12-18-24 125.0 77 (42) 127.0 724.9 Light tan,white,and dark gray, WEATHERED ROCK(WR) 50/0.2 130.0 (50/0.2) 50/0.3 135.0 (50/0.3) 50/0.2 140.0 (50/0.2) 143.5 708.4 Boring Terminated at 143.5'on 50/0.0 145.0 CRYSTALLINE ROCK(CR) (50/0.0) Hard drilling encountered at 127.0 ft. — PAGE: 1 of 3 F)� BORING NO.: GT21 15 JOB NO.: 10292406 DATE: 8/13/2021-8/19/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603996.93000 EASTING: 1313246.74000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 861.2 ft COMPLETION DEPTH: 118.7 WATER TABLE IMMEDIATE: WATER TABLE 24hr:DRY,Cave-in @ 41.2 f D S E Y A � - C9> w � HW M x zw Zo_= zo �= U o T B P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— o W m a L o 0 (ft.) L E C1 g o 8-1 Z x 2 O W U U S Depth Elevation U U) Tan and orange,sandy SILT(ML),stiff, moist(RESIDUUM) 2-4-5(9) 3.5 ______________ 857.7 Orange,tan,and white,silty SAND(SM), 3-4-5(9) 5.0 x loose,wet,micaceous,saprolitic 2-2-3(5) 2-3-3(6) 10.0 5-4-4(8) 15.0 2-3-4(7) 20.0 2-3-3(6) 25.0 2-2-3(5) 30.0 2-2-3(5) 35.0 2-2-3(5) 40.0 2-2-5(7) 45.0 2-3-6(9) — PAGE: 2 of 3 F)l BORING NO.: GT21 15 JOB NO.: 10292406 DATE: 8/13/2021-8/19/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603996.93000 EASTING: 1313246.74000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 861.2 ft COMPLETION DEPTH: 118.7 WATER TABLE IMMEDIATE: WATER TABLE 24hr:DRY,Cave-in @ 41.2 D S S (n w'(n A Lu H ()j Lu aHw >� c o E Y M Hx zw z�x zo CO U 0 T M p DESCRIPTION OF MATERIALS OJ D J �w o Q w(D 0-Z'v w 0 H O L O ¢Z dN oc=nw �Q a o W (ft.) L E 0 a a o j U U S Depth Elevation J Z CA U C/) 3-4-6 55.0 (10) 2-3-6(9) 60.0 2-4-6 65.0 x (10) 2-4-6 70.0 (10) 74.0 787.2 30-50/0.4 75.0 Tan,white,and brown,WEATHERED (50/0.4) ROCK(WR) 17-30- 80.0 50/0.4 (50/0.4) 82.0 _________________ %2 Orange,brown,and tan,silty SAND(SM), medium dense,wet(RESIDUUM) 4-7-11 85.0 x (18) ss.s 771.7 22-45- 90.0 50/0.4 Dark gray and tan,WEATHERED ROCK(WR) (50/0.4) 92.0 _________________ 769.2 Tan,white,and gray,silty SAND(SM),very dense,wet(RESIDUUM) 12-22-49 95.0 (71) 99.0 76z.z 28-50/0.5 — PAGE: 3 of 3 F)� BORING NO.: GT21 15 JOB NO.: 10292406 DATE: 8/13/2021-8/19/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603996.93000 EASTING: 1313246.74000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 861.2 ft COMPLETION DEPTH: 118.7 WATER TABLE IMMEDIATE: WATER TABLE 24hr:DRY,Cave-in @ 41.2 f D S E Y A � - C9> w � HW M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m a L o 0 (ft.) L E C1 g o 8-1 Z w 2 O w U U S Depth Elevation U U) (WR) 24-50/0.5 105.0 (50/0.5) 28-43- 110.0 50/0.4 (50/0.4) 40-50/0.2 115.0 (50/0.2) 119.7 742.5 50/0.1 120.0 Tricone refusal at 118.7'on CRYSTALLINE (50/0.1) ROCK(CR) 50/0.0 (50/0.0) 125.0 130.0 135.0 140.0 145.0 — PAGE: 1 of 3 F)� BORING NO.: GT21 16 JOB NO.: 10292406 DATE: 8/30/2021-8/31/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604376.19000 EASTING: 1313475.09000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 853.3 ft COMPLETION DEPTH: 120.4 WATER TABLE IMMEDIATE: WATER TABLE 24hr:45.8 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o T B P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) Brown and red,elastic SILT(MH),stiff to 77 very stiff,moist(RESIDUUM) 6-5-8 (13) 11-11-12 5.0 (23) 6.0 _________ _______ M4 3 Brown,black,and tan,silty SAND(SM), 3-3-5(8) micaceous,loose to very dense,moist to wet 2-4-5(9) 10.0 2-3-5(8) 15.0 2-4-7 20.0 x (11) 9-9-9 25.0 x (18) 3-4-6 30.0 x (10) 2-5-5 35.0 x (10) 2-2-4(6) 40.0 1-3-4(7) 45.0 2-3-4(7) — PAGE: 2 of 3 F)� BORING NO.: GT21 16 JOB NO.: 10292406 DATE: 8/30/2021-8/31/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604376.19000 EASTING: 1313475.09000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 853.3 ft COMPLETION DEPTH: 120.4 WATER TABLE IMMEDIATE: WATER TABLE 24hr:45.8 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 0 w U U S Depth Elevation U U) 2-3-6(9) 55.0 2-2-4(6) 60.0 2-4-6 65.0 x (10) 10-6-7 70.0 x (13) 4-5-8 75.0 x (13) 3-7-9 80.0 x (16) 6-11-19 85.0 x (30) 5-10-14 90.0 x (24) 7-14-22 95.0 x (36) 12-21-30 — PAGE: 3 of 3 F)� BORING NO.: GT21 16 JOB NO.: 10292406 DATE: 8/30/2021-8/31/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604376.19000 EASTING: 1313475.09000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 853.3 ft COMPLETION DEPTH: 120.4 WATER TABLE IMMEDIATE: WATER TABLE 24hr:45.8 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 O w U U S Depth Elevation U U) 104.5 748.8 13-29- 105.0 Gray and tan,WEATHERED ROCK(WR) 50/0.3 (50/0.3) 20-31- 110.0 50/0.3 (50/0.3) 50/0.4 115.0 (50/0.4) 36-49- 120.0 120.4 732.9 50/0.3 Tricone refusal at 120.4'on CRYSTALLINE (50/0.3) ROCK(CR) 50/0.0 (50/0.0) 125.0 130.0 135.0 140.0 145.0 — PAGE: 1 of 2 F)l BORING NO.: GT21 17 JOB NO.: 10292406 DATE: 10/19/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603284.40000 EASTING: 1320284.19000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 862.0 ft COMPLETION DEPTH: 60 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a o W m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U C/) Dark brown,sandy CLAY(CL),firm,dry 2-3-4(7) (RESIDUUM) 3.5 ----------------- 858.5 Orange and brown,sandy SILT(ML)with 10-5-5 5.0 x sand seams,stiff to firm,saprolitic,wet (10) 4-5-5 (10) 77 2-3-3(6) 10.0 2-3-3(6) 15.0 3-2-3(5) 20.0 2-3-4(7) 25.0 28.5 _________________ 833.5 White,orange,and brown,silty SAND(SM) 7-16-17 30.0 with weathered rock seams,dense to (33) medium dense,wet 28-41- 35.0 >< 50/0.3 (50/0.3) 2-5-17 40.0 x (22) 43.5 __ _________ ____ 818.5 Light brown,sandy SILT(ML),firm to stiff, 4-4-3(7) L x saprolitic,wet 4-4-8 — PAGE: 2 of 2 F)� BORING NO.: GT21 17 JOB NO.: 10292406 DATE: 10/19/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603284.40000 EASTING: 1320284.19000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 862.0 ft COMPLETION DEPTH: 60 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 O w U U S Depth Elevation U U) 3-4-4(8) 55.0 3-6-6 60.0 77, so.o 802.0 (12) Boring Terminated at 60.0'in sandy SILT (ML) 65.0 70.0 75.0 80.0 85.0 90.0 95.0 — PAGE: 1 of 2 F)l BORING NO.: GT21 18 JOB NO.: 10292406 DATE: 10/20/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 600639.28000 EASTING: 1319112.67000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 904.5 ft COMPLETION DEPTH: 50 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a aW m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U C/) Reddish brown,sandy CLAY(CL),very 6-12-13 stiff,dry to moist(RESIDUUM) (25) 10-8-10 5.0 (18) 6.0 898.5 Purple and brown,elastic SILT(MH)with 3-3-4(7) sand seams,soft to very stiff,wet (RESIDUUM) 4-6-8 10.0 (14) 2-2-3(5) 15.0 2-2-2(4) 20.0 2-2-2(4) 25.0 2-3-4(7) 30.0 3-6-6 35.0 x (12) 4-4-7 40.0 x (11) 5-7-10 45.0 x (17) 4-4-4(8) — PAGE: 2 of 2 F)� BORING NO.: GT21 18 JOB NO.: 10292406 DATE: 10/20/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 600639.28000 EASTING: 1319112.67000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 904.5 ft COMPLETION DEPTH: 50 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o T B P DESCRIPTION OF MATERIALS m J U)Uo w(D d Z'a w H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 0- o 8-1 Z 5 O O0 U U S Depth Elevation U U) Boring Terminated at 50.0'in sandy SILT (ML) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 90.0 95.0 — PAGE: 1 of 3 F)� BORING NO.: GT21 19 JOB NO.: 10292406 DATE: 8/18/2021 and 10/06/21 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603556.33000 EASTING: 1311862.51000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 864.7 ft COMPLETION DEPTH: 116.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 12.6 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o T B P DESCRIPTION OF MATERIALS m J �Uo w(D d Z'a � H O O U)Z dN o�iz �Q— o W m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) Red,brown,and purple,elastic SILT(MH), 2-4-5(9) stiff to firm,moist(RESIDUUM) 3-5-6 5.0 (11) 2-3-3(6) 77 2-2-4(6) 10.0 13.5 851.2 Red,brown,and white,silty SAND(SM), 1-2-2(4) 15.0 x very loose,moist to wet,micaceous, saprolitic 2-1-2(3) 20.0 23.5 _______________ 84L2 Brown,orange,and purple,elastic SILT 2-2-2(4) 25.0 x (MH),soft to stiff,wet,micaceous, saprolitic 3-4-7 30.0 x (11) 2-1-3(4) 35.0 38.5 _________________ 826.2 Red,brown,and white,silty SAND(SM), 3-3-5(8) 40.0 loose to very dense,wet,micaceous, saprolitic 3-4-5(9) 45.0 2-4-5(9) — PAGE: 2 of 3 F)� BORING NO.: GT21 19 JOB NO.: 10292406 DATE: 8/18/2021 and 10/06/21 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603556.33000 EASTING: 1311862.51000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 864.7 ft COMPLETION DEPTH: 116.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 12.6 ft D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo �= U o TB P DESCRIPTION OF MATERIALS m J �a w(D d Z'a � H O O U)Z dN o�iz �Q— o W m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 0 w U U S Depth Elevation U U) 2-2-4(6) 55.0 2-4-6 60.0 x (10) 3-4-6 65.0 x (10) 4-6-12 70.0 x (18) 22-35-50 75.0 x (85) 6-9-14 80.0 x (23) 3-7-13 85.0 x (20) 7-10-18 90.0 x (28) 7-13-19 95.0 x (32) 7-16-21 — PAGE: 3 of 3 F)� BORING NO.: GT21 19 JOB NO.: 10292406 DATE: 8/18/2021 and 10/06/21 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603556.33000 EASTING: 1311862.51000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 864.7 ft COMPLETION DEPTH: 116.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr: 12.6 ft D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J �a w(D d Z'a � H O O U)Z dN o�iz �Q— o W m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 0 w U U S Depth Elevation U U) 11-22-26 105.0 x (48) 9-15-21 110.0 x (36) 114.0 750.7 21-50/0.4 115.0 Gray and tan,WEATHERED ROCK(WR) (50/0.4) 115.5 748.2 Tricone refusal at 116.5'on CRYSTALLINE 50/0.0 ROCK(CR) (50/0.0) 120.0 125.0 130.0 135.0 140.0 145.0 — PAGE: 1 of 2 F)� BORING NO.: GT21 20 JOB NO.: 10292406 DATE: 9/29/2021-9/29/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotaryw/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603675.50000 EASTING: 1310874.85000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 874.2 ft COMPLETION DEPTH: 93.9 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo �= U o T B P DESCRIPTION OF MATERIALS m J U)a w(D 0-Z'a H O O U)Z dN o�Z �Q— aiz m m L 0 0 (ft.) L E C1 g o Z �O U U S Depth Elevation U U) Red,brown,and tan,elastic SILT(MH), micaceous,very stiff to very soft,moist to 4-7-10 wet(RESIDUUM) (17) 8-7-8 5.0 77 (15) 2-4-4(8) 77 2-1-3(4) 10.0 WOH-1-1 15.0 x (2) WOH-1-1 20.0 x (2) 2-3-3-(6) 25.0 WOH-3-2 30.0 x (5) WOH-2-2 35.0 x (4) 38.5 _____________ _ 835.7 Gray,brown,and white,silty SAND(SM), 3-4-4(8) 40.0 micaceous,loose to dense,wet 2-2-4(6) 45.0 2-3-5(8) — PAGE: 2 of 2 F)� BORING NO.: GT21 20 JOB NO.: 10292406 DATE: 9/29/2021-9/29/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotaryw/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603675.50000 EASTING: 1310874.85000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 874.2 ft COMPLETION DEPTH: 93.9 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo U)= U o TB P DESCRIPTION OF MATERIALS m J U)a w(D 0-z'a H O O U)Z dN o�iz �Q— aiz m m L 0 0 (ft.) L E C1 g o 8-1 Z S O W U U S Depth Elevation U U) 2-3-4(7) 55.0 6-11-13 60.0 x (24) 5-12-16 65.0 x (28) 7-14-25 70.0 x (39) 74.0 800.2 24-50/0.3 75.0 GraRy)and white,WEATHERED ROCK (50/0.3) 77.0 --- ----- sz2 Gray,white,and tan,silty SAND(SM), micaceous,medium dense,moist 8-12-14 80.0 (RESIDUUM) (26) 81 0 793.2 Gray,brown,WEATHERED ROCK(WR) 50/0.1 85.0 - (50/0.1) 31-50/0.2 90.0 (50/0.2) 93.9 780.3 50/0.4 95.0 WEATHEREDBoring Terminated at 93.9' n (50/0.4) ROCK(WR) — PAGE: 1 of 1 BORING NO.: GT21 21 JOB NO.: 10292406 DATE: 10/18/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 606031.90000 EASTING: 1318766.66000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 778.8 ft COMPLETION DEPTH: 43.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'N A Lu H C�> w Hw a o E Y M ~x zw z�x zo CO U o T M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w 0 � af P _ H O L O ¢Z dN oc=nw LoQ a aW m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U co Dark gray, silty SAND(SM),medium g_14-10 dense,moist(RESIDUUM) (24) 3.5 775.3 Dark brown and orange,sandy CLAY(CL), 3-3-3(6) 5.0 firm to very soft,moist to wet 8-4-3(7) WOH- 10.o WOH-1 (1) 13.5 _________________ 755.3 Dark brown,light gray,and white,silty 1-3-5(8) 15.0 x SAND(SM)with weathered rock seams, loose to very dense,saprolitic,wet 50/0.4 20.0 (50/0.4) 14-11-9 25.0 x (20) 17-24-28 30.0 x (52) 16-25-35 35.0 x (60) 9-13-25 40.0 x (38) 43.5 735.3 Tricone refusal at 43.5'on CRYSTALLINE 50/0.0 45.0 ROCK(CR) (50/0.0) — PAGE: 1 of 1 F)� BORING NO.: GT21 22 JOB NO.: 10292406 DATE: 9/17/2021-9/17/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604327.60000 EASTING: 1318909.49000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 766.1 ft COMPLETION DEPTH: 24.2 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o T B P DESCRIPTION OF MATERIALS m J U)Uo w 0 0-Z'2. H O O U)Z dN 0 �Q— o W m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) Dark brown,silty SAND(SM),loose to medium dense,saprolitic,wet 3-3-4(7) (RESIDUUM) 17-8-7 5.0 77 (15) 3-4-4(8) 77 2-4-4(8) 10.0 2-2-4(6) 15.0 2-4-7 20.0 (11) 24.0 742.1 37-50/0.2 25.0 24.2 Dark brown and white,WEATHERED 741.9 (50/0.2) ROCK WR Tricone refusal at 24.2'on CRYSTALLINE ROCK(CR) 30.0 35.0 40.0 45.0 — PAGE: 1 of 3 F)� BORING NO.: GT21 24 JOB NO.: 10292406 DATE: 9/01/2021-9/2/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotaryw/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605143.49000 EASTING: 1312951.85000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 857.3 ft COMPLETION DEPTH: 132.2 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo �= U o TB P DESCRIPTION OF MATERIALS m J H 0 U)a w(D 0-Z'a H O O U)Z dN o�Z �Q— aiz m m L 0 0 ( ) E to 0 g o o j w y0 �w 0 0 ft. L a 0� S Depth Elevation J Z U U) Red and tan, ELASTIC SILT(MH),stiff, moist(RESIDUUM) 6-6-8 77 (14) 9-6-5 5.0 (11) 6.0 _________________ 651.3 Red,tan,and black,silty SAND(SM),very 3-3-4(7) loose to very dense,micaceous,wet 2-2-4(6) 10.0 2-3-3(6) 15.0 2-4-4(8) 20.0 2-2-3(5) 25.0 30.0 1-2-2(4) 35.0 1-2-2(4) 40.0 4-5-7 45.0 x (12) 1-3-3(6) — PAGE: 2 of 3 F)� BORING NO.: GT21 24 JOB NO.: 10292406 DATE: 9/01/2021-9/2/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotaryw/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605143.49000 EASTING: 1312951.85000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 857.3 ft COMPLETION DEPTH: 132.2 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo U)= U o TB P DESCRIPTION OF MATERIALS m J H 0 U)a w(D 0-z'a H O O U)Z dN o�iz �Q— aiz m m L 0 0 (ft.) L E C1 g o ; w 2 O w U U S Depth Elevation U U) 1-4-8 55.0 x (12) 3-5-5 60.0 x (10) 3-5-6 65.0 (11) 4-6-9 70.0 x (15) 6-6-8 75.0 x (14) 6-12-12 80.0 (24) 7-10-15 85.0 x (25) 6-10-14 90.0 x (24) 8-17-18 95.0 x (35) 17-22-38 — PAGE: 3 of 3 F)� BORING NO.: GT21 24 JOB NO.: 10292406 DATE: 9/01/2021-9/2/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotaryw/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605143.49000 EASTING: 1312951.85000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 857.3 ft COMPLETION DEPTH: 132.2 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo �= U o TB P DESCRIPTION OF MATERIALS m J H 0 U)a w(D 0-Z'a H O O U)Z dN o�Z �Q— aiz m m L 0 0 (ft.) L E C1 g o 8-1 Z S O W U U S Depth Elevation U U) 11-22-36 105.0 x (58) 109.0 748.3 25-50/0.4 110.0 Black,grey and white,WEATHERED (50/0.4) ROCK(WR) 32-50/0.4 115.0 (50/0.4) 50/0.3 120.0 (50/0.3) 44-50/0.3 125.0 (50/0.3) 50/0.2 130.0 (50/0.2) 322 725.1 Tricone refusal at 132.2'on CRYSTALLINE 50/0.0 ROCK(CR) (50/0.0) 135.0 140.0 145.0 — PAGE: 1 of 2 F)l BORING NO.: GT21 25 JOB NO.: 10292406 DATE: 10/26/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605448.63000 EASTING: 1313229.48000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 847.6 ft COMPLETION DEPTH: 60 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a o W m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U C/) Reddish brown,sandy CLAY(CL),very g_10-10 stiff,dry to moist(RESIDUUM) (20) Orange and brown,silty SAND(SM),very 6-8-7 5.0 x loose to medium dense,moist to wet (15) 2-4-7 (11) 77 3-4-5(9) 10.0 3-3-5(8) 15.0 2-4-4(8) 20.0 2-2-2(4) 25.0 2-5-5 30.0 x (10) 2-2-2(4) 35.0 3-4-6 40.0 x (10) 3-6-8 45.0 x (14) 2-4-4(8) — PAGE: 2 of 2 F)� BORING NO.: GT21 25 JOB NO.: 10292406 DATE: 10/26/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605448.63000 EASTING: 1313229.48000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 847.6 ft COMPLETION DEPTH: 60 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— o W m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 O w U U S Depth Elevation U U) 54.5 793.1 7-12- 55.0 - Dark gray,WEATHERED ROCK(WR) 50/0.1 (50/0.1) 26-2- 60.0 sa.a 7a7.s 50/0.4 Tricone refusal at 60.0'on CRYSTALLINE (50/0.4) ROCK(CR) 50/0.0 (50/0.0) 65.0 70.0 75.0 80.0 85.0 90.0 95.0 — PAGE: 1 of 2 F)� BORING NO.: GT21 26 JOB NO.: 10292406 DATE: 10/20/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 602048.32000 EASTING: 1319731.57000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 874.0 ft COMPLETION DEPTH: 50 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) Reddish brown,gray,and white,silty SAND (SM),loose to medium dense,dry to wet 4-6-5 (RESIDUUM) (11) 10-9-10 5.0 (19) 3-5-5 (10) 77 3-4-5(9) 10.0 4-6-6 15.0 x (12) 6-9-6 20.0 x (15) 13-8-9 25.0 x (17) 2-2-3(5) 30.0 2-5-6 35.0 x (11) 4-4-6 40.0 x (10) 5-8-8 45.0 x (16) 5-6-7 — PAGE: 2 of 2 F)� BORING NO.: GT21 26 JOB NO.: 10292406 DATE: 10/20/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 602048.32000 EASTING: 1319731.57000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 874.0 ft COMPLETION DEPTH: 50 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o T B P DESCRIPTION OF MATERIALS m J U)Uo w(D d Z'a w H O O U)Z dN o�iz �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z 5 O O0 U U S Depth Elevation U U) Boring Terminated at 50.0'in silty SAND (SM) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 90.0 95.0 — PAGE: 1 of 2 F)� BORING NO.: GT21 27 JOB NO.: 10292406 DATE: 9/30/2021-9/30/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotaryw/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605285.49000 EASTING: 1312270.61000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 840.7 ft COMPLETION DEPTH: 78.8 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw zwm zo �= U o TB P DESCRIPTION OF MATERIALS m J U)a w(D 0-Z'a L O U)Z dN �Z z H O �Qa� 0m 0 j � L E o y0 0 0o m 0 S Depth Elevation J Z U U) Red and brown,sandy SILT(ML),stiff, moist(RESIDUUM) 7-7-8 (15) 3.5 _ _ 837.2 Red and brown,elastic SILT(MH),very 11-9-11 5.0 x stiff,moist (20) 5-8-10 (18) 6-9-10 10.0 (19) 13.5 _________________ 827.2 Orange,brown,and black,silty SAND 2-3-3(6) 15.0 x (SM),micaceous,very loose to very dense, wet 2-2-3(5) 20.0 3-4-4(8) 25.0 1-3-4(7) 30.0 2-1-3(4) 35.0 40.0 6-4-3(7) 45.0 2-3-6(9) — PAGE: 2 of 2 F)l BORING NO.: GT21 27 JOB NO.: 10292406 DATE: 9/30/2021-9/30/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605285.49000 EASTING: 1312270.61000 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 840.7 ft COMPLETION DEPTH: 78.8 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S (n w'N A Lu H ()j Lu aHw >� c o E Y M Hx zw z�x zo CO U 0 T M p DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af H O L O ¢Z dN oc=nw �Q a o W m (ft.) L E 0 a a o j U U S Depth Elevation J Z CA U C/) 3-6-8 55.0 (14) 3-6-11 60.0 x (17) 11-16-36 65.0 x (52) ss.fi 771.2 13-35- 70.0 50/0.4 Black and white,WEATHERED ROCK(WR) (50/0.4) 33-50/0.4 75.0 (50/0.4) 78.8 761.9 50/0.3 80.0 Boring Terminated at 78.8'in (50/0.3) WEATHERED ROCK(WR) 85.0 90.0 95.0 — PAGE: 1 of 2 F)l BORING NO.: GT21 28 JOB NO.: 10292406 DATE: 10/26/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604531.71000 EASTING: 1312504.64000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 872.6 ft COMPLETION DEPTH: 80 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a o W m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U C/) Reddish brown sandy CLAY(CL),very stiff, 5-10-12 77 dry(RESIDUUM) (22) 3.5 ----------------- 869.1 Light brown,elastic SILT(MH),firm to very 5-7-8 5.0 x stiff,wet (15) 3-5-5 (10) 77 1-3-5(8) 10.0 2-3-4(7) 15.0 2-4-5(9) 20.0 2-4-4(8) 25.0 2-3-3(6) 30.0 2-3-4(7) 35.0 2-3-4(7) 40.0 3-4-5(9) 45.0 8-10-14 — PAGE: 2 of 2 F)� BORING NO.: GT21 28 JOB NO.: 10292406 DATE: 10/26/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604531.71000 EASTING: 1312504.64000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 872.6 ft COMPLETION DEPTH: 80 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN o�iz �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) 2-7-6 55.0 77 (13) sss 814.1 Dark brown,silty SAND(SM),medium 7-8-9 60.0 x dense,saprolitic,wet (17) 5-9-10 65.0 x (19) 68.5 804.1 70.0 _ Light brown,WEATHERED ROCK(WR) 50/0.1 50/0.1 ( ) 50/0.1 75.0 - (50/0.1) 78.5 794.1 Boring Terminated at 78.5'on 50/0.0 80.0 CRYSTALLINE ROCK(CR) (50/0.0) 85.0 90.0 95.0 — PAGE: 1 of 1 F)� BORING NO.: GT21 30 JOB NO.: 10292406 DATE: 10/20/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 606120.53000 EASTING: 1315200.88000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 800.0 ft COMPLETION DEPTH: 17.7 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o T B P DESCRIPTION OF MATERIALS m J U)Uo w 0 0-Z'2. H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E � C1 0- o Z 5 O 00 U U S Depth Elevation U U) Reddish brown and orange,silty SAND (SM),medium dense,saprolitic,dry to wet 7-8-9 (RESIDUUM) (17) 12-12-11 5.0 77 (23) 5-7-6 (13) s.o 791.0 35-50/0.2 10.0 White and light brown,WEATHERED (50/0.2) ROCK(WR) 50/0.2 15.0 (50/0.2) 17.7 782.3 50/0.5 Boring Terminated at 17.7'in (50/0.5) 20.0 WEATHERED ROCK(WR) 25.0 30.0 35.0 40.0 45.0 — PAGE: 1 of 2 F)l BORING NO.: GT21 31 JOB NO.: 10292406 DATE: 10/19/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604879.70000 EASTING: 1316778.56000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 831.8 ft COMPLETION DEPTH: 60 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a o W m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U C/) Reddish brown sandy CLAY(CL),very stiff 10-9-9 to firm,dry to moist(RESIDUUM) (18) 13-7-10 5.0 (17) 3-3-3(6) 8.5 _________________ 823.3 Orange and brown,sandy SILT(ML),firm, 2-2-3(5) 10.0 wet 2-4-3(7) 15.0 3-3-3(6) 20.0 2-2-3(5) 25.0 1-2-3(5) 30.0 2-2-3(5) 35.0 38.5 _________________ 793.3 Dark gray and white,silty SAND(SM), 4-4-3(7) ao.o loose to medium dense,saprolitic,wet 3-5-6 45.0 x (11) 3-5-6 — PAGE: 2 of 2 F)� BORING NO.: GT21 31 JOB NO.: 10292406 DATE: 10/19/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604879.70000 EASTING: 1316778.56000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 831.8 ft COMPLETION DEPTH: 60 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 0 w U U S Depth Elevation U U) 2-2-3(5) 55.0 5-6-10 60.0 so.o 771.8 (16) Boring Terminated at 60'in silty SAND (SM) 65.0 70.0 75.0 80.0 85.0 90.0 95.0 — PAGE: 1 of 2 F)� BORING NO.: GT21 32 JOB NO.: 10292406 DATE: 10/20/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 606086.85000 EASTING: 1317729.44000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 845.8 ft COMPLETION DEPTH: 60 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z �0 U U S Depth Elevation U U) Reddish brown,sandy SILT(ML),stiff to 4-5-6 77 soft,dry to moist(RESIDUUM) (11) 9-7-7 5.0 (14) 2-2-2(4) 8.5 ————————————————— 837.3 White and light brown,silty SAND(SM) 3-7-7 10.0 with rock fragments,medium dense to (14) loose,saprolitic,wet 2-3-4(7) 15.0 18.5 _ _______________ 827.3 White,green,and orange,sandy SILT 3-3-4(7) 20.0 X (ML),soft to firm,saprolitic,wet 1-2-2(4) 25.0 2-3-3(6) 30.0 33.5 White,black,and brown,silty SAND(SM), 2-4-5(9) 35.0 x loose to medium dense,saprolitic,wet 3-6-5 40.0 x (11) 2-3-3(6) 45.0 2-7-11 — PAGE: 2 of 2 F)� BORING NO.: GT21 32 JOB NO.: 10292406 DATE: 10/20/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 606086.85000 EASTING: 1317729.44000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 845.8 ft COMPLETION DEPTH: 60 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z w 2 0 w U U S Depth Elevation U U) 6-10-12 55.0 x (22) 5-7-8 60.0 so.o 785.8 (15) Boring Terminated at 60.0'in silty SAND (SM) 65.0 70.0 75.0 80.0 85.0 90.0 95.0 — PAGE: 1 of 2 BORING NO.: GT21 33 JOB NO.: 10292406 DATE: 10/19/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604262.58000 EASTING: 1319777.01000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 769.5 ft COMPLETION DEPTH: 50 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a aW m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U Cn Reddish brown,sandy CLAY(CL),very stiff 6-9-10 to firm,dry to wet(RESIDUUM) (19) 4-5-8 5.0 (13) 8-9-10 (19) 3-6-7 10.0 (13) 2-3-4(7) 15.0 18.5 ____________ ____ 751.0 Light brown,sandy SILT(ML),firm to very 1-3-3(6) 20.0 stiff,saprolitic,wet 2-2-3(5) 25.0 1-2-3(5) 30.0 2-5-5 35.0 x (10) 2-3-5(8) 40.0 2-4-5(9) 45.0 5-9-12 — PAGE: 2 of 2 F)� BORING NO.: GT21 33 JOB NO.: 10292406 DATE: 10/19/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 604262.58000 EASTING: 1319777.01000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 769.5 ft COMPLETION DEPTH: 50 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o T B P DESCRIPTION OF MATERIALS m J U)Uo w(D d Z'a w H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 0- o 8-1 Z 5 O O0 U U S Depth Elevation U U) Boring Terminated at 50.0'in sandy SILT (ML) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 90.0 95.0 F) -1 PAGE: 1 of 1 l BORING NO.: RC21 JOB NO.: 10292406 DATE: 10/25/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605824.32000 EASTING: 1315383.34000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 844.0 ft COMPLETION DEPTH: 38 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu H ()j Lu aHw >� c o E Y M g ~x zw z�x zo CO U o P M P DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af H O L O ¢Z dN oc=nw �Q a o W m (ft.) L E 0 a a o j U U S Depth Elevation J Z Cn U C/) Orange and brown,sandy CLAY(CL), moist(RESIDUUM) 5.0 6.0 _________________ 838.0 Light brown,sandy SILT(ML),soft to stiff, 3-4-5(9) moist to wet 77 2-2-3(5) 10.0 1-2-3(5) 15.0 1-2-2(4) 20.0 2-2-4(6) 25.0 28.5 _________________ 815.5 Light brown,silty SAND(SM),loose to 3-4-5(9) 30.0 dense,saprolitic,wet 16-15-17 35.0 (32) 36.9 807.1 38.0 White and black,WEATHERED ROCK 806.0 50/0.5 WR (50/0.5) 40.0 Tricone refusal at 38.0'on CYSTALLINE 50/0.0 ROCK(CR) (50/0.0) 45.0 Hand auger from 0 to 5.0 ft for utility clearance. F) -3 PAGE: 1 of 1 l BORING NO.: RC21 JOB NO.: 10292406 DATE: 10/25/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 605912.32000 EASTING: 1315475.64000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 846.0 ft COMPLETION DEPTH: 30 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu H ()j Lu aHw >� c o E Y M g ~x zw z�x zo CO U o P M P DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af H O L O ¢Z aN oc=nw LoQ a aW m (ft.) L E 0 a a o j U U S Depth Elevation J Z Cn U Cn Reddish brown,sandy CLAY(CL)very stiff to stiff,dry to wet(RESIDUUM) 5.0 4-9-12 (21) 3-5-6 10.0 (11) 13.5 _________________ 8325 Red and light brown,sandy SILT(ML),stiff 2-5-8 15.0 to firm,wet (13) 2-4-4(8) 20.0 2-3-3(6) 25.0 2-2-3(5) 30.0 1 1 1 1771 30.0 815.0 Boring Terminated at 30'in sandy SILT (ML) 35.0 Hand auger from 0 to 5.0 ft for utility clearance. 40.0 45.0 F) -5 PAGE: 1 of 1 l BORING NO.: RC21 JOB NO.: 10292406 DATE: 10/15/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 606262.74000 EASTING: 1313740.90000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 787.7 ft COMPLETION DEPTH: 38.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a aW m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U Cn Dark brown and light brown,sandy CLAY (CL),very soft to soft,moist to wet 1-1-1 (2) (ALLUVIUM) 3-2-1 (3) 5.0 6.0 781.7 • Gray,SAND(SP)with gravel and boulders, 50/0.4 • very dense to very loose,wet (50/0.4) •• 1-1-1 (2) 10.0 13.5 _________________ 774.2 Dark gray and dark brown,silty SAND 1-1-2(3) 15.0 x (SM),very loose,wet 20.0 2-1-2(3) 25.0 28.5 759.2 Dark gray and brown,silty SAND(SM), 18-10-12 30.0 medium dense,wet(RESIDUUM) (22) 34.0 753.7-77 8_50/0,2 35.0 Brown,WEATHERED ROCK(WR) (50/0.2) 38.5 749.2 Tricone refusal at 38.5'on CRYSTALLINE 50/0.0 40.0 ROCK(CR) (50/0.0) Encountered boulder at 6.0 ft and refusal at 10.0 ft.Offset 5 ft. 45.0 F) -6 PAGE: 1 of 1 l BORING NO.: RC21 JOB NO.: 10292406 DATE: 10/14/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 606114.82000 EASTING: 1313821.28800 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 785.7 ft COMPLETION DEPTH: 33.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a aW m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U Cn Dark brown,sandy CLAY(CL),firm,dry 1-3-4(7) (ALLUVIUM) 4-5-2(7) 5.0 6.0 779.7 • Dark brown and orange,SAND(SP)with • gravel,very loose to medium dense,wet •• 1-0-12 10.0 •• (12) 13.5 _________________ 772.2 Dark brown,silty SAND(SM),very loose, 1-0-1 (1) 15.0 wet 20.0 25.0 28.0 ----------------- 757.7 Black and white,silty SAND(SM),medium 8-19- 30.o z9.5 dense,sa rolitic,wet RESIDUUM 756.2 50/0.3 Black and white,WEATHERED ROCK (50/0.3) (WR) - 33.5 752.2 Tricone refusal at 33.5'on CRYSTALLINE 50/0.0 35.0 ROCK(CR) (50/0.0) 40.0 45.0 F) -7 PAGE: 1 of 1 l BORING NO.: RC21 JOB NO.: 10292406 DATE: 9/23/2021-9/23/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 606347.84000 EASTING: 1313823.02200 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 787.2 ft COMPLETION DEPTH: 12.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a aW m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U Cn 1.0 Brown,silty SAND(SM)with gravel,moist 785.2 `_(ALLUVIUM_____________/ 4-6-6 Red,elastic SILT(MH)with rock (12) s.s fra9-ments,stiff,_moist,L ESIDUUML__ 7837 7-9-8 5.0 Tan,gray,and brown,silty SAND(SM)with (17) rock fragments,micaceous,loose to medium dense,wet WOH-3-3 (6) s.5 777.7 10-27- 10.0 Tan,brown,and white,WEATHERED 50/0.4 (50/0.4) ROCK(WR) 12.5 774.7 Tricone refusal at 12.5'on CRYSTALLINE 50/0.0 ROCK(CR) (50/0.0) 15.0 20.0 25.0 30.0 35.0 40.0 45.0 — PAGE: 1 of 1 F)� BORING NO.: RC21 8 JOB NO.: 10292406 DATE: 9/23/2021-9/23/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 606199.92000 EASTING: 1313859.40800 LOGGED BY: M.Johnson,TECHNICIAN/HDR VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 787.0 ft COMPLETION DEPTH: 11.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o T B P DESCRIPTION OF MATERIALS m J �Uo w(D d Z'a � H O O U)Z dN o�iz �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) Tan,silty SAND(SM),loose,moist, 2.1 (ALLUVIUM) 755.0 3-4-4(8) -------------------- a.o Brown and red,sandy SILT(ML)with 754.0 quuartz,firm,moist(RESIDUUM)—————7 20-19-7 5.0 Tan,brown,and dark gray,silty SAND (26) (SM),micaceous,medium dense to very loose,wet 2-2-1 (3) WOH-7-3 10.0 (10) 11,0 ns.o 15 WEATHERED ROCK WR ,No recovery7755 50/0.0 Tricone refusal at 11.5'on CRYSTALLINE (50/0.0) ROCK(CR) 15.0 Hard drilling encountered at 11.0 ft. 20.0 25.0 30.0 35.0 40.0 45.0 — PAGE: 1 of 1 F)� BORING NO.: RC21 9 JOB NO.: 10292406 DATE: 10/21/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603780.19000 EASTING: 1317026.50000 LOGGED BY: B Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 766.2 ft COMPLETION DEPTH: 28.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o T B P DESCRIPTION OF MATERIALS m J U)Uo w 0 0-Z'2. H O O U)Z dN 0 �Q— o W m m L 0 0 (ft.) L E C1 g o 8-1 Z �O U U S Depth Elevation U U) Dark brown,silty SAND(SM),very loose to 2-2-2(4) loose,dry to wet(ALLUVIUM) 77 5-4-4(8) 5.0 3-2-1 (3) 8.5 _________________ 757.7 Light brown,SAND(SP)with gravel and 7-10-4 10.0 boulders,very loose to very dense,wet (14) 4-5-8 15.0 (13) 50/0.1 20.0 (50/0.1) 1-2-1 (3) 25.0 2&5 737.7 Tricone refusal at 28.5'on CRYSTALLINE 50/0.0 30.0 ROCK(CR) (50/0.0) 35.0 40.0 45.0 — PAGE: 1 of 1 F)l BORING NO.: RC21 10 JOB NO.: 10292406 DATE: 10/22/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603655.26660 EASTING: 1316976.53000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 769.9 ft COMPLETION DEPTH: 7.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a aW m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U C/) Reddish brown,sandy CLAY(CL)with 2-4-5(9) boulders,stiff,dry to moist(ALLUVIUM) 5.0 5.0 754.9 °0—0 Light gray,BOULDERS with soil seams, 50/0.0 o 0 dry (50/0.0) 0 0 771 7.5 752.4 4-14-28 Tricone refusal at 7.5'in Boulders (42) 10.0 50/0.0 Three attempts,encountered refusal on (50/0.0) Boulders. 15.0 20.0 25.0 30.0 35.0 40.0 45.0 PAGE: 1 of 1 BORING NO.: RC21 11 JOB NO.: 10292406 DATE: 10/25/21 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603818.80850 EASTING: 1317122.55000 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 764.9 ft COMPLETION DEPTH: 11 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S S N w'U) A Lu } C�> Lu Hw c o E Y M g �x zw z�x zo CO U o P M DESCRIPTION OF MATERIALS D J P w U)o Q w(D 0-Z'v w( af P _ H O L O ¢Z dN oc=nw �Q a aW m (ft.) L E ct) 0 a a o � U U S Depth Elevation J Z Cn U C/) Reddish brown,sandy CLAY(CL),stiff to very stiff,dry to moist(ALLUVIUM) 7-7-7 (14) 15-13-10 5.0 (23) Reddish brown and orange,sandy SILT 5-7-10 (ML)with gravel,very stiff,moist (17) 9.a ————————————————--L55.9 7-50/0.4 10.0 °o Light gray,BOULDERS,very dense,wet (50/0.4) 11.0 753.9 Tricone refusal at 11.0'in Boulders 15.0 Three attempts,encountered refusal on Boulders. 20.0 25.0 30.0 35.0 40.0 45.0 — PAGE: 1 of 2 F)� BORING NO.: RC21 12 JOB NO.: 10292406 DATE: 10/21/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603923.64000 EASTING: 1317101.57200 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 766.2 ft COMPLETION DEPTH: 48.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D 0-Z'a � H O O U)Z dN 0 �Q— dW m m L 0 0 (ft.) L E C1 g o 8-1 Z x 2 0 W U U S Depth Elevation U U) Reddish brown,silty SAND(SM),loose,dry (ALLUVIUM) 4-4-5(9) 3.5 _________________ 762.7 Reddish brown,sandy SILT(ML),firm,wet 4-4-3(7) 5.0 2-2-4(6) 8.5 ___ __ _____ 757.7 Dark gray,clayey SAND(SC),very loose, 1-0-2(2) 10.o x wet 13.5 _________________ 752.7 Red and light brown,SAND(SP)with 4-8-9 15.0 gravel,medium dense,wet (17) 18.5 _________________74z7 Brown,gray,and white,silty SAND(SM) 1-2-1 (3) 20.0 x with rock fragments,very loose to medium dense,saprolitic,wet(RESIDUUM) 2-3-2(5) 25.0 3-4-5(9) 30.0 8-9-10 35.0 x (19) 6-12-14 40.0 x (26) 8-12-8 45.0 x (20) 48.5 717.7 Tricone refusal at 48.5'on CRYSTALLINE 50/0.0 — PAGE: 2 of 2 F)� BORING NO.: RC21 12 JOB NO.: 10292406 DATE: 10/21/2021 JOB NAME: Piedmont Lithium Project TYPE OF DRILLING: Mud Rotary w/SPT BORING LOCATION: Gaston County, NC EQUIPMENT: CME55 314425 NORTHING: 603923.64000 EASTING: 1317101.57200 LOGGED BY: B.Weiserbs VERTICAL DATUM: NAVD 88 SURFACE ELEVATION: 766.2 ft COMPLETION DEPTH: 48.5 WATER TABLE IMMEDIATE: WATER TABLE 24hr:NOT MEASURED D S E Y A � - C9> w � HW >_° o 0 M x zw Zw= zo �= U o TB P DESCRIPTION OF MATERIALS m J U)Uo w(D d Z'a w H O O U)Z dN 0 �Q— dW m m L 0 0 E to 0 g o o j w y0 �w U U ft. L a 0 S Depth Elevation J Z U U) ROCK(CR) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 90.0 95.0 APPENDIX B : Laboratory Test Results LIQUID AND PLASTIC LIMITS TEST REPORT 60 , Dashed line indicates the approximate upper limit boundary for natural soils / 50 -- / �0 / /' Ca 40 - / i x / w / o / z U 30 CO / a / � / O 20 C}� 10 - - ML or OL MH or OH i 0 0 10 20 30 40 50 60 70 80 90 100 110 LIQUID LIMIT MATERIAL DESCRIPTION LL PL PI %<#40 %<#200 USCS • Light Yellow-Brown Micaceous Elastic Silt with Sand 56 47 9 98.0 83.9 MH = Light-Brown Sandy Elastic Silt 51 47 4 91.7 68.8 MH A Orange-Brown Sandy Elastic Silt 50 42 8 95.8 68.6 MH • Dark-Brown Micaceous Sandy Silt 46 28 18 78.8 56.6 ML • Light Yellow-Brown Sandy Elastic Silt 58 49 9 88.0 57.8 MH Project No. 6507.L0006 Client: HDR Engineering Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina •Location: GT21-20,SS-3 @ 6'-7.5' ■Location: GT21-20,SS-5 @ 13.5'-15' •Location: GT21-24,SS-2 @ 3.5'-5' +Location: GT21-13,SS-1 @ F-2.5' •Location.GT21-13,SS-5 A 13.5'-15' Summit Engineering Ft. Mill South Carolina Figure Tested By: FG Checked By: MH LIQUID AND PLASTIC LIMITS TEST REPORT 60 / Dashed line indicates the approximate upper limit boundary for natural soils f / 50 / / O / 40 — z—7 — i w / o / z / 30 U C/) / g / / 20 Q� / / / / 10 _77171i C ML or OL MH or OH I 0 0 10 20 30 40 50 60 70 80 90 100 110 LIQUID LIMIT MATERIAL DESCRIPTION LL PL PI %<#40 %<#200 USCS • Orange-Brown Sandy Elastic Silt 56 35 21 89.3 65.5 MH A Dark Red-Brown Micaceous Sandy Elastic Silt 54 35 19 82.4 52.5 MH Project No. 6507.L0006 Client: HDR Engineering Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina •Location: GT21-9,SS-4 @ 8.5'-10' ■'Location: GT21-9, SS-5 @ 13.5'-15' Summit Engineering Ft. Mill South Carolina Figure Tested By: FG Checked By: MH Particle Size Distribution Report C C Q Q Q C C C C C C CO Q 4 [Rp Q to M N \ N X! $k 3k # 100 I I I I I I rll � Til ffil TTI 90 s0 I I I l l I I I ! I I I I I I 1 I l l I I I I I I ! l l W 60 I I I I I f l i I I l l i l Z 50 I I I I I ! I I I I I I I I I I I U I I I I I I I I I I I W 40 ! I I I I I I I I I I I I 30 I I 1 I I I I I I I I I I I 20 I I I I I I I I I I I I I I I I I I I 1 1 I I I f f l l 10 I 1 ! I I I I I I ( I I I I a I I I I I I I 1 11 1 1 1 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.0 2.0 14.1 83.9 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Light Yellow-Brown Micaceous Elastic Silt with Sand 0.375 100.0 #4 100.0 #10 100.0 Atterberg Limits #20 99.7 PL= 47 LL= 56 PI= 9 #40 98.0 #60 94.5 Coefficients #140 86.6 D90= 0.1530 D85= 0.0864 D60= #200 83.9 D50= D30= D15= D10= Cu= Cc= Classification USCS= MH AASHTO= A-5(13) Remarks Moisture Content:44.6% (no specification provided) Location: GT21-20,SS-3 @ 6'-7.5' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. 1111i11 South Carolina Project No: 6507.L0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report C C C C C C W 4 4 d L7 �Cp3 P a 100 I I I I I I ! II I I I I I 90 I I I I I ! I I I I I l l l I I I I I I ! I I I ! I I 80 I I I l i I I I I I E I I I I I I I I I I I I I I W 60 I I I I I I I I 1 1 E 1 1 1 Z 50 I I I I I I f I I W 1 I 1 W 40 a I I I I I I I I I I I I I I I I I I I f l I ! I I I I 1 30 I I I I I I I I I l l l l l 20 I I I I I I I ! I I I I E I I 1 11 1 E I I I I I I I I 10 I I 1 I I I I I I 1 I 1 1 1 o I I I I I I I E I I I I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE -mm. %+3" %Gravel %Sand %Fines Coarse Fine Coarse _Medium Fine Silt Clay 0.0 0.0 0.0 0.0 8.3 22.9 68.8 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Light-Brown Sandy Elastic Silt 0.375 100.0 #4 100.0 #10 100.0 Atterberg Limits #20 97.1 PL= 47 LL= 51 Pl= 4 #40 91.7 #60 84.3 Coefficients #140 73.0 D90= 0.3723 D85= 0.2622 D60= #200 68.8 D50= D30= D15= D10= CU= cc- Classification USCS= MH AASHTO= A-5(5) Remarks Moisture Content:58.0% (no specification provided) Location: GT21-20,SS-5 @ 13.5'-15' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill, South Carolina Project No: 6507.L0006 Fi ure , Tested By: FG Checked By: MH Particle Size Distribution Report C C O O O C C C C C C W O O O O OD O V O 04 100 I 1 I I I I k l l s0 — I I ! 1 I 1 1 I I ! I I I I I I ! I l I I I I I I I I 80 I I ! I I I I I ! I I I I 70Of ! I 1 f ! I I I I I 1 1 I I I I 1 1 I I I I I I I ! 1 1 1 I I I I I I I I W 60 Z 50 I ! l l I ! I 1 I I W I I W 40 - a I 1 I I I I I ! ! I I I I I f l l I I I I 1 1 ! I I 30 I ! 1 1 1 I I I ! I I I l l 20 I I I I I I I I I I I I 1 1 I I I l f l l 10 I I I I I I I I f I I I i l 0 I I I I I ! ! 1 I l l l k 100 10 1 0.1 0.01 0=1 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium =fine _ _ Silt Clay 0.0 0.0 0.0 0.2 4.0 1 27.2 T 68.6 SIEVE PERCENT SPEC." PASS? Material Description SIZE FINER PERCENT (X=NO) Orange-Brown Sandy Elastic Silt 0.375 100.0 #4 100.0 #10 99.8 Atterberg Limits #20 98.9 PL= 42 LL= 50 Pl= 8 #40 95.8 #60 90.3 Coefficients #140 75.9 D90= 0.2435 D85= 0.1742 D60= #200 68.6 D50= D30= D15= D10= Cu= Cc= Classification USCS= MH AASHTO= A-5(7) Remarks Moisture Content:36.0% (no specification provided) Location: GT21-24, SS-2 @ 3.5'-5' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Milt South Carolina Project No: 6507.L0006 Figure Tested By: FG - - Checked By: MH Particle Size Distribution Report C C G G O C C C "z C C C O ID n ryOry O G rop 4_ 7 4 N w \ -v ii # a 7t # ik aL 100 I I I k l I I T T-1 i I I I I I I f ! I I I I I I 80 ! I I I ! I I I I I I I I I 70 I I I 1 I I Of W 60 Z I I I I I I I I I ! I I I LL z 50 1 I 1 1 1 1 I ! I I W W 40 a I I I I I I I ! I I I I I I I I ! I I I I ! I I I I I I 30 I I I I I I I I 1 I ! I ! I 20 I I I I I I I I ! I I I I I 10 I I I I I I I I I I I I I I p I ! ! i I ! I ! E I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE -mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.8 2.8 17.6 22.2 56.6 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Dark-Brown Micaceous Sandy Silt 0.375 100.0 #4 99.2 #10 89.#202 Atterber Limits #40 78.8 PL= 28 LL= 46 Pl= 18 #60 71.2 Coefficients #140 59.8 D90= 0.9035 D85= 0.6301 D60= 0.1081 #200 56.6 D50= D30= D15= D10= Cu= Cc= Classification USCS= ML AASHTO= A-7-6(8) Remarks Moisture Content:26.9% I i (no specification provided) Location: GT21-13, SS-1 @ 1'-2.5' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill, South Carolina Project No: 6507.1,0006 Fl ure Tested By: FG — Checked By: MH Particle Size Distribution Report C C O O O CO t'] N \ \ W N M t0 N 100 90 i I I I I I I I I I I I I I I I l l I I I I I I I I 80 f I I l f I I I I ! I I I I 70 I I I I I I ! ! I I I f I I I I f I I I l l l l w 60 z 50 I I I l l ! f I I ! I I w Q 40 I I I I I I I l f 11 I I I I I I I I I I I ( I I I I 30 I I I l l f l I I I f l l l 20 I I I I I I I I I ! ! I l l 10 I f I I I I I I I I l f l l o Lli 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. +3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 1.8 10.2 30.2 57.8 SIEVE PERCENT SPEC.* PASS? Material Descrii3tion SIZE FINER PERCENT (X=NO) Light Yellow-Brown Sandy Elastic Silt 0.375 100.0 #4 100.0 #10 98.0 Atterberg Limits #40 88.0 PL= 49 LL= 58 PI= 9 #60 81.2 Coefficients #140 65.0 D90= 0.5171 ❑85= 0.3279 D60= 0.0833 #200 57.8 D50= D30= D15= D10= Cu= Cc= Classification USCS= MH AASHTO= A-5(6) Remarks Moisture Content: 54.7% (no specification provided) Location: GT21-13,SS-5 @ 13.5'-15' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.La006 Ft ure Tested By: FG Checked By: MH Particle Size Distribution Report C C O O O DC C C C C O O O O O O O 100 I I I I I I I 1 I I I I I 90 I I I ! I I I I I I l l l I I I f l 11 I I I, I I I 80 , I I 1 1 1 I ! I 1 I f I I 70 1 I I I I I I 1 1 I I ! ! I I I ! I E I I W 60 LL I I I l l I I I ! Z 50 I I l l I I I I I I W I II I I I W 40 I I I I I I I f ! I I I I I 30 I I I I I I f I 1 I l l f l 20 I I I I I I I I I I I I I I ! 1 ! I I I I I f I I I I I 10 I I I l i I I I I I I I I I o I ! I ! I 1 ! I I ! I 1 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt _ Clay 0.0 0.0 1.6 1.9 7.2 23.8 65.5 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Orange-Brown Sandy Elastic Silt 0.375 100.0 #4 98.4 #10 94.2 Atterberg Limits #40 89.3 PL= 35 LL= 56 Pl= 21 #60 83.6 Coefficients #140 69.7 D90= 0.4616 D85= 0.2787 D60= #200 65.5 D50= D30= D15= D10= Cu= Cc= Classification USCS= ME AASHTO= A-7-5(14) Remarks Moisture Content:28.1% (no specification provided) Location: GT21-91 SS-4 @ 8.5'-10' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.1,0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report C C G O O C C C -g C C C O m eoen� c4cqq f! Y 0 M N w 100 I I I I I f l l l l 90 I I I I I I I I I I I I I I I I I I I I I I I I I I I so I I I I I I I I I I I I I I �o I I I I I ! I i I I I I I I I I I I I I I W 60 I I I I I I I I Z 50 I 11 ! I I I 1 I I I I w U ! I I I I I I I I W 40 a I I f l l l i I I I I I I I I I I I I I I I I I I I I I 30 20 i I 1 I I I ! I I I I I I I I I I I I I I I I f ( I I I I 10 I I I I I I I I I I I I I I 0 I I l l I I I I I I 100 10 1 0.1 0.01 0,001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine *2a2 se Medium Fine Silt Clay 0.0 0.0 0.0 15.4 29.9 52.5 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Dark Red-Brown Micaceous Sandy Elastic Silt 0.375 100.0 #4 100.0 #10 97.8 #20 93.6 A_tterberg Limits # 0 93.4 PL= 35 LL= 54 PI= 19 #60 71.3 Coefficients 9140 56.0 D90= 0.6485 D85= 0.4860 D60= 0.1399 #200 52.5 D50= D30= D15= D10= Cu= cc- Classification USCS= MH AASHTO= A-7-5(8) Remarks Moisture Content:35.8% (no specification provided) Location: GT21-9,SS-5 @ 13.5'-15' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.1,0006 Figure Tested By: FG Checked By: MH LIQUID AND PLASTIC LIMITS TEST REPORT 60 / Dashed line indicates the approximate upper limit boundary for natural soils / 50 / 0 / 40 ' X / w 0 / Z / 30 U N / g � / / O 20 V / / 10 CL•nnL ML or OL � � MH or OH I 0 0 10 20 30 40 50 60 70 80 90 160 110 LIQUID LIMIT MATERIAL DESCRIPTION LL PL PI 1 %<#40 %<#200 USCS • Orange-Brown Micaceous Elastic Silt with Sand 61 57 4 92.1 71.4 MH ■ Light-Brown Micaceous Silty Sand 46 32 14 84.2 45.6 SM • Grey-Brown Silty Sand NP NP NP 61.5 37.8 SM • Tan-Brown Micaceous Sandy Elastic Silt 52 46 6 95.3 55.2 MH • Red-Brown Sandy Silt 47 29 18 85.3 68.8 ML Project No. 6507.L0006 Client: HDR Engineering Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina •Location: GT21-18,SS-6 @ 18.5'-20' ■Location: GT21-25,SS-7 @ 23.5'-25' •Location: GT21-26,SS-1 @ 0'-1.5' •Location: GT21-28,SS-5 @ 13.5'-15' T Location: GT21-32.SS-1 1'-2.5' Summit Engineering L Ft. Mill, South Carolina Figure Tested By: FG Checked By: MH LIQUID AND PLASTIC LIMITS TEST REPORT 60 / Dashed line indicates the approximate upper limit boundary for natural soils / 50 / 0 40 / i x w / o / z / 30 / — U C/) / / / O 20 D .. / / 10 — — ML or OL MH or OH 0 0 10 20 30 40 50 60 70 80 90 100 110 LIQUID LIMIT MATERIAL DESCRIPTION ILL PL PI %<#40 %<#200 USCS 0 Orange-Brown Sandy Elastic Silt 53 37 16 95.6 68.7 MH ■ Dark-Brown Sandy Lean Clay 34 24 10 83.3 53.7 CL • Dark Red-Brown Silt with Sand 48 30 18 94.2 79.9 ML • Dark Orange-Brown Sandy Elastic Silt 52 45 7 87.1 61.1 MH • Red-Brown Sandy Silt 49 29 20 90.9 70.1 ML Project No. 6507.L0006 Client: HDR Engineering Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina •Location: GT21-17, SS-4 @ 8.5'-10' ■Location: GT21-21,SS-4 @ 8.5'-10' •Location: GT21-31, SS-1 @ 0'-1.5' •Location: GT21-31,SS-4 @ 8.5'-10' •Location: GT21-33. SS-1 (a, 1'-2.5' Summit Engineering Ft. Mill South Carolina Figure Tested By: FG Checked By: MH LIQUID AND PLASTIC LIMITS TEST REPORT 60 / Dashed line indicates the approximate upper limit boundary for natural soils / 50 � 0 / 40 w / o / z / U30 vi / g / / 20 D` - / / / 10 �-"" ML or OL MH or OH 01/ 0 10 20 30 40 50 60 70 80 90 100 110 LIQUID LIMIT MATERIAL DESCRIPTION LL PL PI %<#40 %<#200 USCS • Orange-Brown Elastic Silt with Sand 54 44 10 96.3 79.1 MH ■ Light Tan-Brown Sandy Elastic Silt 55 55 NP 96.9 68.4 MH • Yellow-Brown Sandy Silt NP NP NP 96.9 51.7 NIL • Dark Red-Brown Sandy Lean Clay 35 23 12 82.2 53.2 CL Project No. 6507.1,0006 Client: HDR Engineering Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina •Location: RC21-1,SS-1 @ F-2.5' ■Location: RC21-1,SS-6 @ 18.5'-20' •Location: RC21-1,SS-7 @ 23.5'-25' •Location: RC21-3,SS-1 @ 1'-2.5' Summit Engineering Ft. Mill South Carolina Figure Tested By: _FG Checked By: MH _ LIQUID AND PLASTIC LIMITS TEST REPORT 60 / Dashed line indicates the approximate upper limit boundary for natural soils / / / 50 / - -- - O / 40 / - i x / w / o / z / U30 - --- — ~ui / / p 20 O - 10 f � - _ L- L ML or OL MH or OH 0 0 10 20 30 40 50 60 70 80 90 100 110 LIQUID LIMIT MATERIAL DESCRIPTION LL PL PI %<#40 %<#200 USCS • Light-Brown Clayey Sand 27 18 9 66.1 39.0 SC ■ Dark-Brown Micaceous Silty Sand NP NP NP 78.5 36.0 SM Project No. 6507.L0006 Client: HDR Engineering Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina ■Location: RC21-1IA,SS-2 @ 3.5'-5' ■Location: RC21-11A,SS-4 @ 8.5'-10' Summit Engineering Ft. Mill, South Carolina Figure Tested By: FG.. __ Checked By: MH Particle Size Distribution Report C C O O O o 000 0 0 � 0 100 ! I I I I I I I I11I I I I 90 I I I I I I I l 1 I I I I I 80 70 1 ! I I I I ! I I I I I I I I I I I I I I I I W 60 LL ! I l l I I I I I 50 U I I f l I I I I I I I I W 40 a I I I I I I I I i I I I I I I I I I I f l I I I I I I I 30 I I l l i I I I I I I I I 20 I I I I I I f ! I I I I I ! I I I I ! I I I I I I ! 10 I I I L I I ! I1 1 oI 1 ! I I I I I l l 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.0 4.4 26.9 68.7 SIEVE PERCENT SPEC' PASS? Materiai Description SIZE FINER PERCENT (X=NO) Orange-Brown Sandy Elastic Silt 0.375 100.0 #4 100.0 #10 100.0 #20 98.8 Atterberg Limits # 0 9 . PL= 37 LL= 53 PI= 16 #60 91.3 Coefficients #140 76.2 D90= 0.2256 D85= 0.1649 D60= #200 68.7 D50= D30= D15= D10= Cu= Cc= Classification USCS= MH AASHTO= A-7-5(12) Remarks Moisture Content:33.1% (no specification provided) Location: GT21-17,SS-4 @ 8.5'-10' Date: 11-17-21 Summit Engineering Client: HDREngineering — Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report C C O O d N 0 O O O_ V N 100 I I I I I I II 1 ! 1 1 1 90 I I I f l I I I ! E I I I 80 1 I I I 1 1 I ! I I I I �o I I 11 1 I E 1 I I I l i 1 1 I I I I I l E Of E i I I I I f I I I I I LU 60 I l i l I I I I I I I Z 50 I I I I I I I I LU I l I 1 I U I I I ! I I I I I I I I I I W 40 I ! I I I l 1 I I I I I I 30 I I I I I 1 1 I I E I I I 1 20 I ! I I I I I E E I I I I I I I I I I I I I f l f l l 10 I 1 I I I I I I I I I 1 1 1 a I I I I I I I I I I I I I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 2.4 14.3 29.6 53.7 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Dark-Brown Sandy Lean Clay 0.375 100.0 #4 100.0 #10 97.6 Atterbe Limits #20 92.6 PL= 24 LL= 34 PI= 10 #40 83.3 #60 73.4 Coefficients #140 58.6 D90= 0.6694 D$5= 0.4704 D60= 0.1165 #200 53.7 D50= D30= D15= D10= CU= cc- Classification USCS= CL AASHTO= A-4(3) Remarks Moisture Content:29.0% r (no specification provided) Location: GT21-21,SS-4 @ 8.5'-10' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report c c o o a C C ii o 0 0 0 to(pp o v o rp CON \ c 100 I I I 1 1 1 I I I 1 I I I I s0 ! ! I I I I I I I I I I I ! ! I I I I l I I I I I I 80 70 I I I I I I I I I I I I i l W 60 ' ZLL I I I ! I I I I ! I I f Z 50LU I ! I I I I 1 I I I I I I I W 40 (- I I I I I I I I I I I I I I 30 I I I I I I ! I I I I I I I 20 I I 1 1 ! I I I I I I I I I I I I I I I I I I I I l l l 10 I ! I I I I I I I I I I I I p 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse +_Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.4 0.6 4.8 1 14.3 79.9 SIEVE PERCENT SPEC.* PASS? Material Descr pjicn SIZE FINER PERCENT (X=NO) Dark Red-Brown Silt with Sand 0.375 100.0 #4 99.6 #10 99.0 Atterlaerg Limits #20 97.2 PL= 30 LL= 48 PI= 18 #40 94.2 #60 90.8 Coefficients #140 82.9 D90= 0.2261 D85= 0.1319 D60= #200 79.9 D50= D30= D15= D10= Cu= Cc= Classification USCS= ML AASHTO= A-7-5(16) Remarks Moisture Content:20.5% (no specification provided) Location: GT21-31,SS-1 @ 0'-1.5' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report c c c � c C C ap Q q O O ppppp o V o 0 M N 100 I I IT 11 1 1 1 90 I I I I I 1 1 I I I l i a 1111 I I i 1 1 1 1 I I I I I I 80 I I I I I I I I I I I I I �a I I I I I I I 1 I I I I I I I W 60 LL I I I I ! I I 1 1 1 1 Z 50 I 1 1 1 I l l i cW.� I I f 1 1 1 1 I f I I I I I W 40 a I I I I I I I I I I I I I I l I I I I I I I I I I I I I 30 I I I l l ! I I I I I I I I 20 I I I I I I I I I I ! I I I I I I I I I I I I 10 I I I I I I I I k I I I I I q I I I I I I I I I I I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.9 12.0 26.0 61.1 SIEVE PERCENT SPEC.* , PASS? Material,Description SIZE FINER PERCENT I (X=NO) Dark Orange-Brown Sandy Elastic Silt 0.375 100.0 #4 100.0 #10 99.1 20 94.2 Atteri�erg Limits # # 0 94.1 PL= 45 LL= 52 Pl= 7 #60 81.3 Coefficients #140 67.4 D90= 0.5564 D85= 0.3469 D60= #200 61.1 D50= D30= D15= D10= CUE Cc= Classification USCS= MH AASHTO= A-5(5) Remarks Moisture Content:42.0% (no specification provided) Location: GT21-31,SS-4 @ 8.5'-10' Date: 11-17-21 Summit Engineering Client: HDR Engineering — — Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Proiect No: 6507.L0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report E v o a 100 1 I I I I I I I I I I I I 90 I I 1 1 1 I I I ! I I I I I I I I I I I f I I I I 80 I t I I W 60 I I 1 i l I I I I i l l l i Z 50 U of I I I I I I I I I I I I a ao I I 1 1 1 I I I I I I I I I I I I I I I I ! I I I I ! 1 30 I f I I I I I I i I 1 1 1 1 20 ! I I I I I I I I I I I I I i I I l l I I I I I I I I I 10 I I I I I I I 1 I I I I I I p I I I I I ! I I I I I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 1.1 1.6 6.4 20.8 70.1 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Red-Brown Sandy Silt 0.375 100.0 #4 98.9 #10 97.3 #20 94.7 Atterberg Limits #40 90.9 PL= 29 LL= 49 PI= 20 #60 86.1 Coefficients #140 74.9 D90= 0.3774 D85= 0.2265 D60= #200 70.1 D50= D30= D15= D10= Cu= Cc= Classification USCS= ML AASHTO= A-7-6(14) Remarks Moisture Content:20.7% (no specification provided) Location: GT21-33,SS-1 @ F-2.5' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Pra'ect No: 6507.L0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report � 5 O O o C C C C C C W O O O O (Op O O 00) N \ \ Yt Q A `W at at ac 100 I I 1 I I I I I I I I I I I so i i I I I 1 1 I 1 i I I I I 1 I l f I I I i I I I I s0 , I I I I I I I I I i l l I I I I I I I I I ! I I I I I W 60 LL I I I I I ! 1 I I 1 1 1 Z 50 I I I I I I I I I I W W 40 30 I I I I I I I I I I I I I I 20 I I I I I I I I I I I I ! I I I I I I I I I I I I 10 I I I I ! I I I I I I I I I o 1 1 1 1 1 1 I 1 f l l l l 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.0 7.9 20.7 71.4 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Orange-Brown Micaceous Elastic Silt with Sand 0.375 100.0 #4 100.0 #10 100.0 # 0 99.2 A_tter6erg Limi 2 ts # 0 92.1 PL= 57 LL= 63 PI= 4 #60 87.7 Coefficients #140 77.3 D90= 0.3341 D85= 0.1899 D60= #200 71.4 D50= D30= D15= D10= Cu= Cc= Classification USCS= MH AASHTO= A-5(8) Remarks Moisture Content:56.6% (no specification provided) Location: GT21-18,SS-6 @ 18.5'-20' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.1,0006 Figure Tested By: FIG Checked By: MH Particle Size Distribution Report c c c � c m o ry [0[�77 o rc[ppa 4o v N 100 I I I I I I I ! I ! I l l 90 I I 11 1 I I I I I I I I I I ! 1 1 1 I I I I I I I I s0 , I I I I I I I I I f l l F l �o ! l 1 1 I I I I 1 ! I I I I I I I I I ! I 1 LI 60 I I I I I I I I I I I Z 50 ! ! I I I I ! I f I ! ! ! v I I I I I I I 1 I I I I I W 40 30 I I I I I 11 I 1 I I I I I 20 I I I I I I I I I I ! I l l 1 1 I I I I I I I 10 I I I I I I I i I I I I I I q 1 I I I 1 I I I I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.2 15.6 38.6 45.6 SIEVE PERCENT SPEC." PASS? Material Description SIZE FINER PERCENT (X=NO) Light-Brown Micaceous Silty Sand 0.375 100.0 #4 100.0 #10 99.8 # Atterberg Limi 20 95.5 ts # 0 95.2 PL= 32 LL= 46 P1= 14 #60 70.9 Coefficients #140 51.2 D90= 0.5694 D85= 0.4402 D60= 0.1612 #200 45.6 D50= 0.0989 D30= D15= 1310= CU= Cc= Classification USCS= SM AASHTO= A-7-5(4) Remarks Moisture Content:47.4% (no specification provided) Location: GT21-25,SS-7 @ 23.5'-25' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.1,0006 Figure Tested By: FIG _ Checked By: MH Particle Size Distribution Report c ca a C C C C C C O N M o a G v 100 I I I I I 1 1 I I I I I I 90 1 I I l l I I I I I I I I I I I I I I I I I I I I I 80 1 I I I I I I I I I I I I 11 1 11 I I 1 1 1 1 1 I I I I I 11 I I I I I W 60 Z I I I I I I I I I I I Z 50 I I I I I I I I ! k l I I I k 1 1 1 v I I 1 1 1 I I I I 1 1 1 1 1 W 40 a I I I I I ! I I I I I I I I f I f I l i i 30 I I I I I 1 1 I 1 I I I I I 20 I 1 I I I I I I ! I I I I I ! I I I I I ! I f f l 1 10 1 I I I I I I I ILill 10 I 1 I I II I 11-1 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %,+3" %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.0 4.7 40.1 55.2 SIEVE PERCENT SPEC.* PASS? Material Descri tion SIZE FINER PERCENT (X=NO) Tan-Brown Micaceous Sandy Elastic Silt 0.375 100.0 #4 100.0 #10 100.0 # 0 99 Atterberg Limi 2 .0 ts # 0 9 .3 PL= 46 LL= 52 PI= 6 #60 86.5 Coefficients #140 64.0 D90= 0.2964 D85= 0.2336 D60= 0.0909 #200 55.2 D50= D30= D15= D10= CU= Cc= Classification USCS= MR AASHTO= A-5(4) Remarks Moisture Content:43.4% (no specification provided) Location: GT21-28,SS-5 @ 13.5'-15' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG . Checked By: MH Particle Size Distribution Report C C Q a Q C C C C C C 0 y O O Q Q O O_ I 6 (O M N n 7! Xk # 100 I I I I I I i i l l l l so I I I I I I I I I I l l s 80 , I i I I 1 I I I I I I I I 70 I I I I I ! I I I ! I I I I I I I ! I I I I I W 60 I ! I I I I I I 1 1 1 1 1 Z 50 ! ! cW.� I I I I I I I I I I ! I I I a- W 40 a I 1 I I I I ! I I I I I I I I I I I I I I I ! ! 1 1 ! I 30 I I I l l ! I I I 1 1 1 1 1 20 I ! I I I I I I I I I I I I I I I i t I I I I I I I 10 I I I I I I I I I I E I I I 0—] I 1 I I I I I 1 I l l l l 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %.Sand %Fines Coarse Fine Coarse Medium Fine Silt _ Clay 0.0 0.0 0.6 3.0 11.1 1 16.5 68.8 SIEVE I PERCENT SPEC." PASS? Material Description SIZE FINER PERCENT (X=NO) Red-Brown Sandy Silt 0.375 100.0 #4 99.4 #10 96.4 A_tterberg Limits #20 91.4 PL= 29 LL= 47 Pl= 18 #40 85.3 #60 80.0 Coefficients #140 71.8 D90= 0.7136 D85= 0.4122 D60= #200 68.8 D50= D30= D15= D10= Cu= Cc= Classification USCS= ML AASHTO= A-7-6(12) Remarks Moisture Content:20.0% (no specification provided) Location: GT21-32,SS-1 @ F-2.5' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report 000 C3 0 qd In C3 V C) 100 r I I I I I I I I ! I I I 90 I ! I I I I I I 1 I I I I so I I I I I I I I I I I I I I �o I I I l 1 1 I 1 I I I I I I I I I I I ! 1 I I I I I Of w 60 Z LL Z 50 I I I I I I ! 1 I I I I U ! I I I I I I I I I I W 40 30 I I I I 1 I I I I I I I I I 20 I I I I I I I ! I I I I I I 10 I I I I I I I I I I I I I I o I I I I I I I I I I I I [ 100 1❑ 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines i Coarse_ Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.0 3.7 17.2 79.1 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Orange-Brown Elastic Silt with Sand 0.375 100.0 #4 100.0 #10 100.0 #20 98.9 Atter#,erg Limits # 0 96.3 PL= 44 LL= 54 P1= 10 #60 93.6 Coefficients #140 85.0 D90= 0.1590 D85= 0.1062 D60= #200 79.1 D50= D30= D15= D10= CU= cc- Classification USCS= MH AASHTO= A-5(12) Remarks Moisture Content:27.2% (no specification provided) Location: RC21-1,SS-1 @ F-2.5' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure 11 Tested By: FG Checked By: MH Particle Size Distribution Report C y O O O C C C C C C O N M O 0 O N 100 I I I I I 11 I I 1 1 1 so I ! I I I I I 1 ! I I I I 1 I ! I I I I 1 I I I I I I 60 I I I I I I I I I I I I I I 70 I I l l 11 I I I I I I W 6LL I I I I I I I I I I I I Z 50 I I I I I I U I I 1 1 I I I I I I of W 40 a I I I I I I I I I I I I I I I I I I I I I I I ! I I I I 30 20 I I f l ! I I ! I 1 I I l l I I I I ! I I I I 10 I ! I I I I I I I I I I I I 0 I I I l l I I ! I l l l l l 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. ado+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium _Fine Silt Clay 0.0 0.0 0.0 0.3 2.8 28.5 68.4 T SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Light Tan-Brown Sandy Elastic Silt 0.375 100.0 #4 100.0 #10 99.7 #20 98.1 Atterlserg Limits # 0 96.9 PL= 55 LL= 55 Pl= NP 960 94.4 Coefficients #140 78.3 D90= 0.1796 D85= 0.1391 D60= #200 68.4 D50= D30= D15= D10= Cu= Cc= Classification USCS= MH AASHTO= A-5(4) Remarks Moisture Content:60.5% (no specification provided) Location: RC21-1,SS-6 @ 18.5'-20' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report C C p p p C C C C C C m O g [Q� P G Q Y N 100 I I I I I I I ! I I I I I so I I I I I I I I I I I I I I I I I I I I I l i l l l 80 I I I I I 1 ! I I I I I ! 70 ! 1 ! I I I I I I W 60 l i l I Z so I I I I I I I I I I I I LI 40 a I 1 1 1 I I I I I I I ! I I I I I I I I I I I I I 30 I I I I I I I I I E I ! I ! 20 I I 1 1 1 I I I 1 1 1 10 ! I I I I I I I I I I I l l 0 100 10 1 0.1 0.01 0.001 GRAIN SIZE -mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse��22.5 dium Fine Silt Clay 0.0 0.0 4.7 6.7 1 27.1 39.0 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Light-Brown Clayey Sand 0.375 100.0 #4 95.3 #10 88.6 # � 77 Atterberg Lim! 20 .6 ts # 0 77.1 PL= 18 LL= 27 PI= 9 #60 57.2 Coefficients #140 43.4 D90= 2.3271 D85= 1.4490 D60= 0.2950 #200 39.0 D50= 0.1629 D30= D15= D10= Cu= Cc= Classification USCS= Sc AASHTO= A-4(0) Remarks Moisture Content: 17.2% (no specification provided) Location: RC21-11A,SS-2 @ 3.5'-5' Date: 11-17-21 Summit 'Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG ___ Checked By: MH Particle Size Distribution Deport c o 0 0 M Od (Op 100 I ! I I l I I II 1 I 1 I f l 90 I I I I I I I I I I l i l l I I I I I I I I I I I I I I 80 I ! I I I I I I I I I I I I I I I 1 1 ! I I I I I w 60 LL IV z soI I I v a 40 I I I I I I I I ! I I I I I I I I I I I I I l ! I I 30 I 1 I I I ! I I I I I I I I 20 ! 1 1 I I I I 1 I 1 1 1 I I I I I I I I I I I I I I 10 ! Ji o d I I I I I I I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.3 2.1 19.1 42.5 1 36.0 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Dark-Brown Micaceous Silty Sand 0.375 100.0 #4 99.7 #10 97.6 Atterberg Limits #20 90.0 PL= NP LL= NP PI= NP #40 78.5 #60 65.3 Coefficients #140 43.7 D90= 0.8468 D85= 0.5975 D60= 0.2044 #200 36.0 D50= 0.1381 1)30= D15= D10= Cu= Cc= Classification USCS= SM AASHTO= A-4(0) Remarks Moisture Content: 32.6% (no specification provided) Location: RC21-1IA,SS-4 @ 8.5'-10' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report Q O � C C C 100 I I I I I I I 1 I I I I I 90 I I I I l l I I I I I I I 1 11 1 1 1 I I I I I I I 80 �o I I I I ! ! I I I I I I I I I I I I I I I I I I I I W 60 I I ! f l I I I I f l l l l Z 50 ! I ! I I I U W 40 a I I I I I I ! I I I I I I 11 ! I I I I I I I I ! 30 I ! I I I I I I I ! ! ! k f 20 I I I I 1 1 I ! I I I I I I I I I I i t I I I I I I I 10 I 1 I I I I I ! I I I I I I 0 I I I ! I I I I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3" %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay_ 0.0 0.0 0.3 2.3 35.9 23.7 37.8 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Grey-Brown Silty Sand 0.375 100.0 #4 99.7 #10 97.4 20 79.4 Atteri�erg Limits # # 0 61. PL= NP LL= NP PI= NP #60 51.6 Coefficients #140 40.9 D90= 1.3017 D85= 1.0540 D60= 0.3975 #200 37.8 D50= 0.2246 D30= D15= D10= CU= Cc= Classification USCS= SM AASHTO= A-4(0) Remarks Moisture Content: 8.9% (no specification provided) Location: GT21-26,SS-1 @ 0'-1.5' Date: 11-17-21 Summit Engineering Client: HDREngineering — Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.1,0006 Figure Tested By: FG Checked By: MH Particle Size Distribution Report C C A O O 100 I I I I I I I I I I I I I 90 I 1 I I I I I l I I I I I I 1 1 f l l I l I I I I I I 80 70 I I I I I I ! W 60 Z 50 I I f I I I I I I W I ! f 1 I ! W 40 a I I I l i I I I I I I I I I I I I I I I I I I I I I I I 30 20 I I l l 1 1 1 I 1 I I 1 1 1 I I I I I I I I i I I I I I 10 I I I I I I I I I I I I I I o ! 1 I I I I I I I I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 1.5 2.4 13.9 29.0 53.2 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Dark Red-Brown Sandy Lean Clay 0.375 100.0 #4 98.5 #10 96.1 #20 89.8 Attertlerq Limits # 0 82.2 PL= 23 LL= 35 PI= 12 460 74.4 Coefficients #140 58.5 D90= 0.8694 D85= 0.5347 D60= 0.1156 #200 53.2 D50= D30= D15= D10= Cu= Cc= Classification USCS= CL AASHTO= A-6(4) Remarks Moisture Content: 13.3% (no specification provided) Location: RC21-3,SS-1 @ F-2.5' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Fi ure Tested By: FIG - Checked By: MH Particle Size Distribution Report C C O O O O O O O V O (D M N \ C n # # # # # # 100 I I 1 1 1 I I I I I I ! ! 90 I I I I I ! I I I I 1 1 1 I I I I I I ! I I I I I I I a0 1 1 I I I I l i I I I I I I i I I I 1 1 I I I I I I I W 60 Z I I 11 ! I I I I I I I Z 50 ! I 11 1 1 1 I I I IF ! I I cw.> W 40 a I 1 I I I 1 1 I I I I I I I 30 I I I I I I I I ! I I I I I 20 I I I I I I I I I I I I I I 10 o 11 ! I I l l l l l 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %.+3„ %Gravel %Sand %.Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.0 3.1 45.2 51.7 SIEVE PERCENT SPEC." PASS? Materiai_Description SIZE FINER PERCENT (X=NO) Yellow-Brown Sandy Silt 0.375 100.0 #4 100.0 #10 100.0 # 0 99 Atterl3erp Limi 2 .0 ts # 0 96.9 PL= NP LL= NP P1= NP #60 89.3 Coefficients #140 62.7 D90= 0.2587 D85= 0.2111 D60= 0.0975 #200 51.7 D50= D30= D15= D10= Cu= Cc= Classification USCS= ML AASHTO= A-4(0) Remarks Moisture Content: 54.9% (no specification provided) Location: RC21-1,SS-7 @ 23.5'-25' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mil!, South Carolina Project No: 6507.1,0006 Figure Tested By: FG Checked By: MH Consolidation Test Report -4 I 4 I II 8 I 12 c 16 U a 20 24 28 ril 32 k � ___ � � �� �� 77 FMF Ei � Hff_t� 36 1 .2 .5 1 2 5 10 20 Applied Pressure- ksf Coefficients of Consolidation and Secondary Consolidation No. Load Cv Ca No. Load Cv Ca No. Load Cv Ca (ksf) (in.2/sec.) (ksf) (in.2/sec.) (ksf) (in. 2/sec.) 2 0.25 0.0031 12 4.00 0.0044 3 0.50 0.0093 13 8.00 0.0042 4 1.00 0.0028 14 16.00 0.0061 5 2.00 0.0026 15 32.00 0.0029 6 1.00 0.0051 16 16.00 0.0049 7 0.50 0.0027 17 4.00 0.0013 8 0.25 0.0036 18 1.00 0.0007 9 0.50 0.0024 19 0.25 0.0004 10 1.00 0.0102 11 1 2.00 0.0012 Natural Dry Dens. LL PI Sp. Overburden Pc cc Cr Swell Press. Heave e° Sat. Moist. (pcf) Gr. (ksf) (ksf) (ksf) % 92.9% 61.8% 37.2 59 1 2.70 6.36 0.83 0.04 1.797 MATERIAL DESCRIPTION USCS AASHTO Light-Brown Micaceous Silty Sand SM A-5(0) Project No. 6507.L0006 Client: HDR Engineering Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-1 @ 15'-17' Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-1 @]a 15'-17' tso Iso 00078 Load#2 003C Load#3 0.25 ksf 0.50 ksf 000az C,@ 1.15 min.- .0032 c,@ 0.38 min.= 0.0031 i,L2f,�tc. a.o093 v,.ars�. .00086 [ .0034 00090 4rl .0036 00094 .0038 c � C C {gyp .00098 .0040 N � .00102 .0042 .00106 .0044 00110 .0046 .00114 .0048 .00118 0 00 125 2.50 3.75 5.00 6.25 7,50 8.75 10.00 11-5 12.50 .0050 700 1 25 2,50 3.75 5.00 6.25 7.50 975 10.00 1115 12.7. Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) tg0 190 .0112 Load#4 .02498 Load#5 1.00 ksf 2.00 ksf .0116 @ 122 min,= .02573 C,@ L24 min.= 0.8028 i1L21scc. 0.0026 401sec. .0120 .02648 .0124 .02723 -- --.0128 --.02798 - C C C C .0132 N •02873 of _N 6 .0136 .02948 .0140 .03023 .0144 03098 �y .0148 .03173 .0152 0 4 8 12 18 20 24 28 36 40 .03246 0 2 4 6 8 if) 12 14 16 18 20 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.1,0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,STA @ 15'-17' 190 Aso .029175 Load#6 02684 Load#7 1.00 ksf 0.50 ksf .029100 C,@ 0.65 min.= 02668 C,tr 1.25 min.= 0.0051 in,21sec. 0.0027 in.2/sec. .029025 .02654 .028950 .02639 -�-028875 --.02624 � c C C -028800 .02609 of .028725 .02594 -028M .02579 .026575 •02564 .028500 •02549 7 .028425 0 2 4 6 8 10 12 14 16 18 20 ��0.00 1.25 2.50 3.75 MU 6.25 7,50 8.75 10.00 1125 12.5 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min) t90 190 .0240 Load#8 .02278 Load#9 0.25 ksf 0.50 ksf 0238 C',@ 0.93 min.- 02263 Cv @ 1.39 min.- 0 OW6 in 2/sec. 0.0024 in.2lsec. .0236 .02288 i .0234 .02293 - -- 0232 --.02298 C C C C .0230 .02303 m m 022E .02308 .0226 -02313 -0224 .02318 .o222 .02323 .0220 0 0 2.5 5-0 7.5 10.0 12.5 15.0 17.5 24.0 22-5 MID -02328 0.0 2.5 5-0 7.5 10.0 12.5 15-0 17.5 20.0 22.5 25.0 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-1 @ 151-17' .024752 `40 .03020 r90 Load#10 Load#11 1.00 ksf 2.00 ksf C@.024827 .03045 v . „ 2.72 m in= 0,0102in.2/sec. 0.00 in 21sec. .024202 .03070 .024977 .03095 -�.025052 --.03120 C C C C .025127 .03745 of m m .025202 .03170 .025277 .03195 .025352 .03220 .025427 .03245 .025502 0,00 1.25 2,50 3.75 5.00 6.25 7.50 8.75 10.00 71.25 12,50 .03270 a 2 4 6 a 10 12 114 SB 18 20 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) ! 0 t90 .05444 Load#12 .105 Load#13 4.00 ksf 8.00 ksf .05569 C❑@ 0.71 min.= .108 C,@ 0.66 min.= 0.0044 in.21sce. 0.0042 in.21s". .05694 - .111 - .05819 .114 .-.05944 --.117 - C C � C .06069 .120 N W_ .06194 .123 .06319 .126 - .06444 .129 08$89 .132 0fi694 Q 2 4 fi 8 1Q 12 to 16 18 20 .135 0 4 8 12 18 80 24 28 32 36 40 Square Root of Elapsed Time(min) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County, North Carolina Location: GT21-19,ST-I @ 1S-17 �90 Aso .1467 Load#14 .13 Load#15 16.00 ksf 32.00 ksf .1542 Cv @ 0.39 min.= .15 C,@ 0.75 min.- 0.0061 i0lsec- iI.UO?9 in.Z+sec. .1617 .17 .1692 .19 -.1767 c c c c .1842 .23 of of m m 0 .1917 25 .1992 .27 2087 .29 .2142 .31 22170.00 1.25 2-50 3.75 5.00 6.25 7.50 8.75 10.00 1125 i2.50 30 2 4 fi a 10 12 14 ie i8 20 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) t90 190 .292 Load#16 .281 Load#17 16.00 ksf 4.00 ksf .291 C,.@ 0.36 min.= 279 cy 1.50 m n= 0.0049 irL21W. 0.0013 ia2lsec. .290 -277 289 275 --.268 --.273 c c c c 287 .271 m An .286 .269 285 .267 .284 .265 .283 .263 .282 0 2 4 5 8 10 12 14 Sfi 18 20 261 0 3 6 9 12 15 18 21 24 27 30 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-1 15'-17' � �o .266 Load#18 249 Load#19 1.00 ksf 0.25 ksf .264 C,{fit 2.70 min.= 247 G,Q 5.39 min._ 0.0007 iIL2.sec. 0.0004 in.2lsee. .262 .245 .260 .243 -..256 -- 241 C C C � .256 N -239 of N D .254 •237 .252 .235 .260 .233 2ae .231 246 o 2 4 e a 10 12 14 16 18 20 .22s 0 4 a 12 16 20 24 26 32 35 .0 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure CONSOLIDATION TEST DATA Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County, North Carolina Project Number: 6507 .L0006 Sample Data Source: Sample No. : Elev. or Depth: Sample Length(in. /cm. ) : Location: GT21-19, ST-1 @ 15 ' -17 ' Description: Light-Brown Micaceous Silty Sand Liquid Limit: 59 Plasticity Index: 1 USCS: SM AASHTO: A-5 (0) Figure No. : Testing Remarks: Test Specimen Data TOTAL SAMPLE BEFORE TEST AFTER TEST Wet w+t = 125 . 66 g. Consolidometer # = 1 Wet w+t = 106. 38 g. Dry w+t = 77 . 66 g. Dry w+t = 77 . 66 g. Tare Wt. _ . 00 g. Spec. Gravity = 2 . 70 Tare Wt. _ . 00 g. Height = 1 . 00 in. Height = 1 . 00 in. Diameter = 2 . 50 in. Diameter = 2 . 50 in. Weight = 77 . 66 g. Defl. Table = 1 Moisture = 61. 8 o Ht. Solids = 0 . 3576 in. Moisture = 37 . 0 % Wet Den. = 60 . 3 pcf Dry Wt. = 48 . 00 g. Dry Wt. = 77 . 66 g. * Dry Den. = 37 . 2 pcf Void Ratio = 1 . 797 Void Ratio = 1. 135 Saturation = 92 . 9 % * Final dry weight used in calculations End-of-Load Summary Pressure Final Machine Cv Ca Void % Compression (ksf) Dial (in. ) Defl. (in. ) (in.2/sec. ) Ratio /Swell start 0 . 00000 1 . 797 0 . 10 0 . 00000 0 . 00000 1 . 797 0 . 0 Swell 0 . 25 0 . 00190 0 . 00080 0 . 0031 1 . 794* 0 . 1 Comprs . * 0 . 50 0 . 00630 0 . 00160 0 . 0093 1 . 785* 0 . 4 Comprs . * 1 . 00 0 . 01780 0 . 0031 . 0 . 0028 1 . 760* 1. 3 Comprs . * 2 . 00 0 . 03550 0 . 00490 0 . 0026 1 . 716* 2 . 9 Comprs . * 1 . 00 0 . 03330 0 . 00480 0 . 0051 1. 716* 2 . 9 Comprs . * 0 . 50 0 . 02980 0 . 00430 0 . 0027 1 . 724* 2 . 6 Comprs . * 0 . 25 0 . 02620 0 . 00390 0 . 0036 1 . 732* 2 . 3 Comprs . * 0 . 50 0 . 02710 0 . 00390 0 . 0024 1 . 732* 2 . 3 Comprs. * 1. 00 0 . 02980 0 . 00440 0 . 0102 1 . 726* 2 . 5 Comprs . * 2 . 00 0 . 03760 0 . 00530 0 . 0012 1. 709* 3. 1 Comprs . * 4 . 00 0 . 07290 0 . 00700 0 . 0044 1 . 624* 6. 2 Comprs . * 8 . 00 0 . 13850 0 . 00930 0 . 0042 1 . 459* 12. 1 Comprs . * Summit Engineering Pressure Final Machine Cv Ca Void % Compression (ksf) Dial (in. ) Defl. (in. ) (in.2/sec. ) Ratio /Swell 16. 00 0 . 21760 0 . 01180 0 . 0061 1 . 244* 19 . 7 Comprs . * 32 . 00 0 . 30720 0 . 01420 0 . 0029 0 . 996* 28 . 6 Comprs . * 16. 00 0 . 29630 0 . 01330 0 . 0049 1. 002* 28 . 4 Comprs . * 4 . 00 0 . 27410 0 . 01080 0 . 0013 1 . 051* 26. 7 Comprs . * 1 . 00 0 . 25490 0 . 00800 0 . 0007 1. 097* 25. 0 Comprs . * 0 . 25 0 . 23640 0 . 00660 0 . 0004 1. 135* 23 . 7 Comprs . * *CALCULATED USING D100 INSTEAD OF FINAL READING Cc = 0 . 83 Pc = 6. 36 ksf Cr = 0 . 04 - Pressure: 0 .25 ksf TEST READINGS Load No. 2 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 00000 11 60 . 00 0 . 00190 2 0 . 10 0 . 00170 3 0 . 25 0 . 00175 4 0 . 50 0 . 00180 5 1 . 00 0 . 00185 6 2 . 00 0 . 00190 7 4 . 00 0 . 00190 8 8 . 00 0 . 00190 9 15 . 00 0 . 00190 10 30 . 00 0 . 00190 Void Ratio = 1 . 794 Compression = 0 . 1 % >>> CALCULATED USING D100 DO = 0 . 00082 D90 = 0 . 00106 D100 = 0 . 00109 Cv at 1 .2 min. = 0 . 0031 in. 2/sec. Pressure: 0 .50 ksf TEST READINGS Load No. 3 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 00190 11 60 . 00 0 . 00630 2 0 . 10 0 . 00520 3 0 . 25 0 . 00550 4 0 . 50 0 . 00560 5 1 . 00 0 . 00570 6 2 . 00 0 . 00580 7 4 . 00 0 . 00590 8 8 . 00 0 . 00610 9 15. 00 0 . 00620 10 30 . 00 0 . 00623 Void Ratio = 1 . 785 Compression = 0 . 4 % >>> CALCULATED USING D100 D0 = 0 . 00308 D90 = 0 . 00395 D100 = 0 . 00405 Cv at 0 . 4 min. = 0 . 0093 in. 2/sec. - Summit Engineering Pressure: 1 . 00 ksf TEST READINGS Load No. 4 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 00630 11 60 . 00 0 . 01710 2 0 . 10 0 . 01510 12 120 . 00 0 . 01740 3 0 . 25 0 . 01550 13 240 . 00 0 . 01760 4 0 . 50 0 . 01580 14 480 . 00 0 . 01770 5 1 . 00 0 . 01600 15 720 . 00 0 . 01780 6 2 . 00 0 . 01610 7 4 . 00 0 . 01630 8 8 . 00 0 . 01650 9 15 . 00 0 . 01670 10 30 . 00 0 . 01690 Void Ratio = 1.-760 Compression = 1 . 3 % >>> CALCULATED USING D100 Do = 0 . 01169 D90 = 0 . 01293 D100 = 0 . 01306 Cv at 1 .2 min. = 0 . 0028 in. 2/sec. Pressure: 2 .00 ksf TEST READINGS Load No. 5 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 01780 11 60 . 00 0 . 03540 2 0 . 10 0 . 03190 12 120 . 00 0 . 03550 3 0 . 25 0 . 03270 4 0 . 50 0 . 03310 5 1 . 00 0 . 03350 6 2 . 00 0 . 03380 7 4 . 00 0 . 03420 8 8 . 00 0 . 03440 9 15. 00 0 . 03480 10 30 . 00 0 . 03510 Void Ratio = 1. 716 Compression = 2 . 9 % >>> CALCULATED USING D100 D0 = 0 . 02649 D90 = 0 . 02870 D100 = 0 . 02894 Cv at 1 .3 min. = 0 . 0026 in. 2/sec. Pressure: 1 . 00 ksf TEST READINGS Load No. 6 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03550 11 60 . 00 0 . 03330 2 0 . 10 0 . 03370 12 120 . 00 0 . 03330 3 0 . 25 0 . 03360 4 0 . 50 0 . 03350 5 1. 00 0 . 03350 6 2 . 00 0 . 03340 7 4 . 00 0 . 03340 8 8 . 00 0 . 03340 9 15 . 00 0 . 03340 10 30. 00 0 . 03330 Void Ratio = 1. 716 Compression = 2 . 9 % >>> CALCULATED USING D100 D0 = 0 . 02906 D90 = 0 . 02870 D100 = 0 . 02866 Cv at 0 . 7 min. = 0 . 0051 in. 2/sec. Summit Engineering Pressure: 0 .50 ksf TEST READINGS Load No. 7 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03330' 11 60 . 00 0 . 02980 2 0 . 10 0 . 03060 3 0 . 25 0 . 03050 4 0 . 50 0 . 03040 5 1. 00 0 . 03030 6 2 . 00 0 . 03030 7 4 . 00 0 . 03020 8 8 . 00 0 . 03010 9 15. 00 0 . 03000 10 30 . 00 0 . 02990 Void Ratio = 1 . 724 Compression = 2 . 6 % >>> CALCULATED USING D100 DO = 0 . 02643 D90 = 0 . 02600 D100 = 0 . 02595 Cv at 1 .3 min. = 0 . 0027 in. 2/sec. Pressure: 0 .25 ksf TEST READINGS Load No. 8 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 02980 11 60 . 00 0 . 02640 2 0 . 10 0 . 02740 12 120 . 00 0 . 02630 3 0 . 25 0 . 02730 13 240 . 00 0 . 02620 4 0 . 50 0 . 02710 5 1 . 00 0 . 02700 6 2 . 00 0 . 02690 7 4 . 00 0 . 02690 8 8 . 00 0 . 02680 9 15. 00 0 . 02660 10 30 . 00 0 . 02650 Void Ratio = 1. 732 Compression = 2 . 3 % >>> CALCULATED USING D100 DO = 0 . 02376 D90 = 0 . 02311 D100 = 0 . 02304 Cv at 0 . 9 min. = 0 . 0036 in. 2/sec. Pressure: 0 .50 ksf TEST READINGS Load No. 9 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 02620 11 60 . 00 0 . 02710 2 0 . 10 0 . 02680 12 120 . 00 0 . 02710 3 0 . 25 0 . 02680 13 240 . 00 0 . 02710 4 0. 50 0 . 02685 5 1. 00 0 . 02690 6 2 . 00 0 . 02690 7 4 . 00 0 . 02695 8 8 . 00 0 . 02700 9 15 . 00 0 . 02700 10 30 . 00 0 . 02710 Void Ratio = 1 . 732 Compression = 2 . 3 % >>> CALCULATED USING D100 DO = 0 . 02284 D90 = 0 . 02300 D100 = 0 . 02302 Cv at 1 .4 min. = 0 . 0024 in. 2/sec. - Summit Engineering Pressure: 1 .00 ksf TEST READINGS Load No. 10 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 02710 11 60 . 00 0 . 02980 2 0 . 10 0 . 02940 3 0 . 25 0 . 02950 4 0 . 50 0 . 02950 5 1 . 00 0 . 02950 6 2 . 00 0 . 02960 7 4 . 00 0 . 02960 8 8 . 00 0 . 02970 9 15 . 00 0 . 02970 10 30 . 00 0 . 02980 Void Ratio = 1 . 726 Compression = 2 . 5 % >>> CALCULATED USING D100 D0 = 0 . 02483 D90 = 0 . 02510 D100 = 0 . 02513 Cv at 0 .3 min. = 0 . 0102 in. 2/sec. Pressure: 2 . 00 ksf TEST READINGS Load No. 11 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 02980 11 60 . 00 0 . 03740 2 0 . 10 0 . 03590 12 120 . 00 0 . 03760 3 0 . 25 0 . 03610 4 0 . 50 0 . 03620 5 1. 00 0 . 03640 6 2 . 00 0 . 03660 7 4 . 00 0 . 03670 8 8 . 00 0 . 03690 9 15 . 00 0 . 03700 10 30 . 00 0 . 03720 Void Ratio = 1 . 709 Compression = 3 . 1 % >>> CALCULATED USING D100 D0 = 0 . 03045 D90 = 0 . 03134 D100 = 0 . 03144 C. at 2 .7 min. = 0. 0012 in. 2/sec. Pressure: 4 .00 ksf TEST READINGS Load No. 12 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03760 11 60 . 00 0 . 07230 2 0 . 10 0 . 06490 12 120 . 00 0 . 07290 3 0 . 25 0 . 06690 4 0 . 50 0 . 06790 5 1 . 00 0 . 06870 6 2 . 00 0 . 06950 7 4 . 00 0 . 07010 8 8 . 00 0 . 07060 9 15 . 00 0 . 07120 10 30 . 00 0 . 07180 Void Ratio = 1. 624 Compression = 6. 2 % >>> CALCULATED USING D100 D0 = 0 . 05570 D90 = 0 . 06126 D100 = 0 . 06188 C. at 0 .7 min. = 0 . 0044 in. 2/sec. Summit Engineering Pressure: 8 . 00 ksf TEST READINGS Load No. 13 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 07290 11 60 . 00 0 . 13540 2 0 . 10 0 . 12060 12 120 . 00 0 . 13630 3 0 . 25 0 . 12580 13 240 . 00 0 . 13710 4 0 . 50 0 . 12800 14 480 . 00 0 . 13780 5 1. 00 0 . 12950 15 720 . 00 0 . 13820 6 2 . 00 0 . 13070 16 960 . 00 0 . 13850 7 4 . 00 0 . 13190 8 8 . 00 0 . 13290 9 15. 00 0 . 13370 10 30 . 00 0 . 13460 Void Ratio = 1 . 459 Compression = 12 . 1 % >>> CALCULATED USING D100 D0 = 0 . 10598 D90 = 0 . 11925 D100 = 0 . 12072 Cv at 0 . 7 min. = 0. 0042 in. 2/sec. Pressure: 16 .00 ksf TEST READINGS Load No. 14 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 13850 11 60 . 00 0 . 21760 2 0 . 10 0 . 19230 3 0 . 25 0 . 20320 4 0 . 50 0 . 20740 5 1 . 00 0 . 20990 6 2 . 00 0 . 21180 7 4 . 00 0 . 21310 8 8 . 00 0 . 21440 9 15. 00 0 . 21540 10 30 . 00 0 . 21650 Void Ratio = 1. 244 Compression = 19 . 7 % >>> CALCULATED USING D100 D0 = 0 . 16174 D90 = 0 . 19391 D100 = 0 . 19748 Cv at 0 .4 min. = 0 . 0061 in. 2/sec. Pressure: 32 .00 ksf TEST READINGS Load No. 15 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 21760 11 60 . 00 0 . 30600 2 0 . 10 0 . 21940 12 120 . 00 0 . 30720 3 0 . 25 0 . 24550 4 0 . 50 0 . 28100 5 1 . 00 0 . 29270 6 2 . 00 0 . 29790 7 4 . 00 0 . 30070 8 8 . 00 0 . 30240 9 15 . 00 0 . 30390 10 30 . 00 0 . 30490 Void Ratio = 0 . 996 Compression = 28 . 6 % >>> CALCULATED USING D100 D0 = 0 . 15426 D90 = 0 . 27314 D100 = 0 . 28635 Cv at 0 .7 min. = 0 . 0029 in. 2/sec. Summit Engineering Pressure: 16.00 ksf TEST READINGS Load No. 16 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 30720 11 60 . 00 0 . 29640 2 0 . 10 0 . 30010 12 120 . 00 0 . 29630 3 0 . 25 0 . 29820 4 0 . 50 0 . 29770 5 1. 00 0 . 29730 6 2 . 00 0 . 29710 7 4 . 00 0 . 29690 8 8 . 00 0 . 29670 9 15. 00 0 . 29660 10 30 . 00 0 . 29650 Void Ratio = 1. 002 Compression = 28 . 4 % >>> CALCULATED USING D100 D0 = 0 . 29007 D90 = 0 . 28465 D100 = 0 . 28405 Cv at 0 .4 min. = 0 . 0049 in. 2/sec. Pressure: 4 .00 ksf TEST READINGS Load No. 17 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 29630 11 60 . 00 0 .27500 2 0 . 10 0 . 28520 12 120 . 00 0 . 27480 3 0 . 25 0 . 28300 13 240 . 00 0 . 27440 4 0 . 50 0 . 28120 14 480 . 00 0 . 27410 5 1 . 00 0 . 27930 6 2 . 00 0 . 27780 7 4 . 00 0 . 27690 8 8 . 00 0 . 27630 9 15 . 00 0 . 27580 10 30 . 00 0 . 27550 Void Ratio = 1. 051 Compression = 26. 7 % >>> CALCULATED USING D100 D0 = 0 . 27674 D90 = 0 . 26769 D100 = 0 . 26668 Cv at 1 .5 min. = 0 . 0013 in. 2/sec. Pressure: 1 . 00 ksf TEST READINGS Load No. 18 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 27410 11 60 . 00 0 . 25540 2 0 . 10 0 . 26960 12 120 . 00 0 . 25490 3 0 . 25 0 . 26720 4 0 . 50 0 . 26510 5 1. 00 0 . 26270 6 2 . 00 0 . 26030 7 4 . 00 0 . 25860 8 8 . 00 0 . 25740 9 15 . 00 0 . 25670 10 30 . 00 0 . 25590 Void Ratio = 1 . 097 Compression = 25. 0 % >>> CALCULATED USING D100 D0 = 0 . 26354 D90 = 0 . 25164 D100 = 0 . 25031 Cv at 2 .7 min. = 0 . 0007 in. 2/sec. - Summit Engineering Pressure: 0 .25 ksf TEST READINGS Load No. 19 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 25490 11 60 . 00 0 . 24020 2 0 . 10 0 . 25270 12 120 . 00 0 . 23910 3 0 . 25 0 . 25150 13 240 . 00 0 . 23820 4 0 . 50 0 .25020 14 480 . 00 0 . 23700 5 1. 00 0 . 24860 15 720 . 00 0 . 23670 6 2 . 00 0 . 24680 16 960 . 00 0 . 23640 7 4 . 00 0 .24490 8 8 . 00 0 .24350 9 15. 00 0 . 24230 10 30 . 00 0 . 24120 Void Ratio = 1 . 135 Compression = 23 . 7 % >>> CALCULATED USING D100 DO = 0 . 24710 D90 = 0 . 23776 D100 = 0 . 23672 Cv at 5. 4 min. = 0 . 0004 in. 2/sec. - - Summit Engineering Consolidation Test Report -4 4 8 c 12 c 16 U U d 20 24 28 71 32 36 1 2 .5 1 2 5 10 20 Applied Pressure-ksf Coefficients of Consolidation and Secondary Consolidation Load C Load C Load Cvsec ) C No. (ksf) (in.2/sec.) Ca NO' NO(ksf) (in.2/sec.) Ca ' (ksf) (in.2/ . a 2 0.25 0.0038 12 4.00 0.0046 I 3 0.50 0.0049 13 8.00 1 0.0042 4 1.00 0.0027 14 16.00 0.0033 5 2.00 0.0048 15 32.00 0.0027 6 1.00 0.0011 16 16.00 0.0026 7 0.50 0.0031 17 4.00 0.0012 8 0.25 0.0087 18 1.00 0.0011 9 0.50 0.0050 19 0.25 0.0004 10 1.00 0.0050 11 2.00 0.0076 Natural Dry Dens, c Crp. Overburden Pc C Swell Press. Heave e° Sat. Moist. (pcf) LL PI Gr. (ksf) (ksf) (ksf) % 94.9% 69.1 % 56.8 68 4 2.70 3.58 0.83 0.04 1.965 MATERIAL DESCRIPTION USCS AASHTO Light-Brown Micaceous Silty Sand SM A-5(2) Project No. 6507.L0006 Client: HDR Engineering (Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19, ST-2 @ 18'-20' Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-2 @ 18'-20' Aso tso .0019 Load#2 .0070 Load#3 0.25 ksf 0.50 ksf .0021 Cv @ 0.93 min= .0074 Cv @ 0.71 min.= 0,0039 im21Sm. 0.0049 in.2lsec_ .0023 .0078 .0025 .0082 .0027 .0086)L c � .0029 4090 ly of .0031 .0094 .0033 .0055 A035 .0102 0037 .0106 LL .00390,00 125 2-50 3-75 5.40 5.25 7.50 8.75 10.00 11-25 12.50 .01100.00 1.25 2.50 3.75 5.00 6.25 7.50 8.75 10.00 11.25 12.5 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) t90 t90 0180 Load#4 03350 Load#5 1.00 ksf 2.00 ksf 0185 CV @ 1.26 min.- 03475 C�,@ 0.67 min.= 6.0027 oL2lsec, 0.0048 in.Zlsec. .0190 .03500 .0195- .03725 --.0200 - --.03850 - c � c_ m .0205 .03975 .0210 .04100 .0215 .04225 .0220- .04350 1 .0225 I .04475 I 0230 0 4! 8 1� 16 20 24 28 36 40 04600 0 2 4 6 8 10 12 14 16 18 20 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT2.1-19,ST-2 @ 1W-201 t90 uao .04165 Load#6 03934 Load#7 1.00 ksf 0.50 ksf .04160 Cv @ 2.99 min= .03919 Cv @ 1.07 min= 0.0011 in.21sce. 0.0031 in.2lsec. .04155 .03904 .04150 •IN" .04145 --.03874 C C C C -04140 .03859 D .04135 .038" .04130 .03829 N\ .04125 .03814 04120 .03799H J 04115 0 2 4 5 4 10 12 14 16 18 20 .03784 0.00 1.25 2.50 3 75 5.00 6-25 7.50 6.75 MOO 11-25 12 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) t90 190 03674 Load#8 .03498 Load#9 0.25 ksf 0.50 ksf 03649 C'1@0.3 8 min= 03502 CV[N]0.65 min= 0.0067 in.2/sec. 0.0050 in.2/sec. 03624 .03506 03599 - .03510 -� 03574 --.03514 c � c � 03549-- .03514 - m � 03524 03522 03499 .03526 03474 .03530 - .03449 .03534 - -03424 0 2 4 6 8 10 12 14 16 16 20 .03538 0 0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 MO 22.5 SOSquare Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-2 @ 18'-24' tso tso ,0371 Load#10 .0425 Load#11 1.00 ksf 2.00 ksf .0372 Cv @ 0.65 min-- .0429 Cv t@ 0.43 min.= 0.0050 in.2/w a.0076 in.2/sec. .0373 .0433 .0374 .0437 --.0375 --.0441 c � .0376 .0445 m � .0377 .0449 .0378 .0453 .0379 b -0457 0380 .0461 .03810.00 1.25 2.50 3.75 5A0 5,25 7.50 &75 10.00 11.25 $2.50 .04650 2 4 6 8 10 12 14 16 18 20 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Igo t90 055 Load#12 .1068 Load#13 4.00 ksf 8.00 ksf .069 Cv @ 0.66 min= -1143 v @ 0.63 min= n _.0.0046 ialec. 4C42 ils 072 .1218 .075 .1293 - 078 -.1368 c 5 c_ c m 081 1443 of m m 084 0 .1518 087 1593 090 .1668 .093 .1743 096 0 2 4 6 8 10 12 14 16 18 20 .1818 0 4 8 12 10 20 24 28 32 36 40 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-2 @ 18'-20' too lso 1799 Load#14 2174 Load#15 16.00 ksf 32.00 ksf 1874-- - Cv @ 0.67 mus= 2299 Cv�fj 0.69 min= 0.0033 in.2/ec. 0.0027 in.2/sec. .1949 .2424 .2024 .2549 l .2099 .2674 .2174 .2799 of of C' 2249 .2924 .2324 .3049 2399 .3174 2474 .3299 .2549 0 2 4 8 8 10 12 14 1S 18 20 •342d 0 2 4 6 5 10 12 14 15 18 20 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) 100 t90 .3266 Load#16 .31945 Load#17 16.00 ksf 4.00 ksf .3264 Cv @ 0.63 min.= 31820 A ,@ 1.35 min=0.00z6 i,421sec. 00i2 in.2/xc. .3262 .31695 .3260 -31570 .3258 --.31445 C = � C .3256 W .313zn .3254 .31195 .3252 .37070 .3250 .30945 .3248 .30820 .3248 0 2 4 5 a 10 12 14 18 18 20 •30695 0 4 8 12 16 20 24 28 32 36 40 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-2 @ 18'-20' �90 too .3135 Load#18 293 Load#19 1.00 ksf 0.25 ksf .3110 Cv @ 1.52 min.— -291 Cv @ 4.89 tnin.— Ohl)1 l im,tsec. MOO in 2hec- .3085 .289 .3060 .267 .3035 .285 c c c c .3010 .283 of _m m .2985 0 281 .2960 279 -2935 k, .277 .2910 .275 LL 2885 0 2 4 6 8 10 12 14 18 18 20 273 0 5 10 15 20 25 30 35 40 45 Ai Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min-) Summit Engineering Ft. Mill, South Carolina Figure CONSOLIDATION TEST DATA Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County, North Carolina Project Number: 6507 .L0006 Sample Data Source: Sample No. : Elev. or Depth: Sample Length(in./cm. ) : Location: GT21-19, ST-2 @ 18 ' -20 ' Description: Light-Brown Micaceous Silty Sand Liquid Limit: 68 Plasticity Index: 4 USCS: SM AASHTO: A-5 (2) Figure No. : Testing Remarks: Test Specimen Data TOTAL SAMPLE BEFORE TEST AFTER TEST Wet w+t = 123 . 86 g. Consolidometer # = 2 Wet w+t = 107 . 40 g. Dry w+t = 73 . 25 g. Dry w+t = 73 . 25 g. Tare Wt. _ . 00 g. Spec. Gravity = 2 . 70 Tare Wt. _ . 00 g. Height = 1 . 00 in. Height = 1 . 00 in. Diameter = 2 . 50 in. Diameter = 2 . 50 in. Weight = 123 . 86 g. Defl. Table = 2 Moisture = 69. 1 % Ht. Solids = 0 . 3373 in. Moisture = 46. 6 % Wet Den. = 96. 1 pcf Dry Wt. = 73 . 25 g. Dry Wt. = 73 . 25 g. * Dry Den. = 56. 8 pcf Void Ratio = 1 . 965 Void Ratio = 1. 134 Saturation = 94 . 9 % * Final dry weight used in calculations End-of-Load Summary Pressure Final Machine Cv Ca Void % Compression (ksf) Dial (in. ) Defl. (in. ) (in.2/sec. ) Ratio /Swell start 0 . 00000 1 . 965 0 . 10 0 . 00000 0 . 00000 1 . 965 0 . 0 Swell 0 . 25 0 . 00430 0 . 00080 0 . 0038 1 . 957* 0 . 3 Comprs . * 0 . 50 0 . 01140 0 . 00150 0 . 0049 1 . 938* 0 . 9 Comprs . * 1 . 00 0 . 02480 0 . 00240 0 . 0027 1. 904* 2 . 1 Comprs . * 2 . 00 0 . 04710 0 . 00380 0 . 0048 1. 845* 4 . 0 Comprs . * 1 . 00 0 . 04480 0 . 00360 0 . 0011 1. 843* 4 . 1 Comprs . * 0 . 50 0 . 04100 0 . 00300 0 . 0031 1 . 851* 3 . 8 Comprs . * 0 . 25 0 . 03690 0 . 00240 0 . 0087 1 . 860* 3 . 5 Comprs . * 0 . 50 0 . 03780 0 . 00250 0 . 0050 1 . 861* 3. 5 Comprs . * 1. 00 0 . 04100 0 . 00300 0 . 0050 1 . 853* 3. 8 Comprs . * 2 . 00 0 . 04990 0 . 00390 0 . 0076 1 . 834* 4 . 4 Comprs . * 4 . 00 0 . 09590 0 . 00580 0 . 0046 1. 715* 8 . 4 Comprs . * 8 . 00 0 . 17180 0 . 00780 0 . 0042 1. 508* 15 . 4 Comprs . * Summit Engineering Pressure Final Machine Cv Ca Void % Compression (ksf) Dial (in. ) Defl. (in. ) (in.2/sec. ) Ratio /Swell 16. 00 0 . 25430 0 . 01030 0 . 0033 1. 268* 23. 5 Comprs . * 32 . 00 0 . 34120 0 . 01230 0 . 0027 1. 018* 31. 9 Comprs. * 16. 00 0 . 33630 0 . 01160 0 . 0026 1. 001* 32 . 5 Comprs. * 4 . 00 0 . 31700 0 . 00880 0 . 0012 1. 045* 31. 0 Comprs . * 1 . 00 0 . 29770 0 . 00670 0. 0011 1. 090* 29. 5 Comers . * 0 . 25 0 . 27920 0 . 00520 0 . 0004 1. 134* 28 . 0 Comers . * *CALCULATED USING D100 INSTEAD OF FINAL READING Cc = 0 . 83 Pc = 3 . 58 ksf Cr = 0 . 04 Pressure: 0 .25 ksf TEST READINGS Load No. 2 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 00000 11 60 . 00 0 . 00430 2 0 . 10 0 . 00320 3 0 . 25 0 . 00330 4 0 . 50 0 . 00350 5 1 . 00 0 . 00360 6 2 . 00 0 . 00370 7 4 . 00 0 . 00390 8 8 . 00 0 . 00400 9 15 . 00 0 . 00410 10 30 . 00 0 . 00420 Void Ratio = 1 . 957 Compression = 0 . 3 % >>> CALCULATED USING D100 DO = 0 . 00214 D90 = 0 . 00279 D100 = 0 . 00286 C. at 0. 9 min. = 0 . 0038 in. 2/sec. Pressure: 0 .50 ksf TEST READINGS Load No. 3 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 00430 11 60 . 00 0 . 01140 2 0 . 10 0 . 00950 . 25 3 0 . 25 0 . 01000 4 0 . 50 0 . 01030 5 1 . 00 0 . 01050 6 2 . 00 0 . 01060 7 4 . 00 0 . 01080 8 8 . 00 0 . 01100 9 15. 00 0 . 01120 10 30 . 00 0 . 01130 Void Ratio = 1 . 938 Compression = 0 . 9 % >>> CALCULATED USING D100 DO = 0 . 00740 D90 = 0 . 00889 D100 = 0 . 00906 C. at 0 . 7 min. = 0 . 0049 in. 2/sec. Summit Engineering Pressure: 1 . 00 ksf TEST READINGS Load No. 4 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 01140 11 60 . 00 0 . 02420 2 0 . 10 0. 02130 12 120 . 00 0 . 02440 3 0 . 25 0 . 02210 13 240 . 00 0 . 02460 4 0 . 50 0 . 02240 14 480 . 00 0 . 02480 5 1. 00 0 . 02270 15 720 . 00 0 . 02480 6 2 . 00 0 . 02300 7 4 . 00 0 . 02320 8 8 . 00 0 . 02340 9 15 . 00 0 . 02370 10 30 . 00 0 . 02390 Void Ratio = 1 . 904 Compression = 2 . 1 % >>> CALCULATED USING D100 D0 = 0 . 01851 D90 = 0 . 02039 D100 = 0 . 02060 Cv at 1 .3 min. = 0 . 0027 in. 2/sec. Pressure: 2 . 00 ksf TEST READINGS Load No. 5 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 02480 11 60 . 00 0 . 04700 2 0 . 10 0 . 04060 12 120 . 00 0 . 04710 3 0 . 25 0 . 04250 4 0 . 50 0 . 04340 5 1 . 00 0 . 04400 6 2 . 00 0 . 04460 7 4 . 00 0 . 04510 8 8 . 00 0 . 04550 9 15 . 00 0 . 04600 10 30 . 00 0 . 04640 Void Ratio = 1 . 845 Compression = 4 . 0 % >>> CALCULATED USING D100 D0 = 0 . 03476 D90 = 0 . 03983 D100 = 0 . 04040 Cv at 0.7 min. = 0 . 0048 in. 2/sec. Pressure: 1 .00 ksf TEST READINGS Load No. 6 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 04710 11 60 . 00 0 . 04480 2 0 . 10 0 . 04510 12 120 . 00 0 . 04480 3 0 . 25 0 . 04510 4 0 . 50 0 . 04510 5 1 . 00 0 . 04500 6 2 . 00 0 . 04490 7 4 . 00 0 . 04490 8 8 . 00 0 . 04490 9 15 . 00 0 . 04480 10 30 . 00 0 . 04480 Void Ratio = 1 . 843 Compression = 4 . 1 % >>> CALCULATED USING D100 D0 = 0. 04159 D90 = 0 . 04130 D100 = 0 . 04127 Cv at 3.0 min. = 0 . 0011 in. 2/sec. -- - - Summit Engineering Pressure: 0 .50 ksf TEST READINGS Load No. 7 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 04480 11 60 . 00 0 . 04100 2 0 . 10 0 . 04180 3 0 . 25 0 . 04170 4 0 . 50 0 . 04160 5 1 . 00 0 . 04150 6 2 . 00 0 . 04150 7 4 . 00 0 . 04130 8 8 . 00 0 . 04120 9 15 . 00 0 . 04110 10 30 . 00 0 . 04110 Void Ratio = 1. 851 Compression = 3 . 8 % >>> CALCULATED USING D100 Do = 0 . 03896 D90 = 0 . 03850 D100 = 0 . 03845 Cv at 1.1 min. = 0 . 0031 in. 2/sec. Pressure: 0 .25 ksf TEST READINGS Load No. 8 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 04100 11 60 . 00 0 . 03710 2 0 . 10 0 . 03830 12 120 . 00 0 . 03690 3 0 . 25 0 . 03800 4 0 . 50 0 . 03790 5 1 . 00 0 . 03780 6 2 . 00 0 . 03770 7 4 . 00 0 . 03760 8 8 . 00 0 . 03750 9 15 . 00 0 . 03740 10 30 . 00 0 . 03720 Void Ratio = 1. 860 Compression = 3 . 5 % >>> CALCULATED USING D100 D0 = 0 . 03642 D90 = 0 . 03555 D100 = 0 . 03545 Cv at 0 . 4 min. = 0 . 0087 in. 2/sec. Pressure: 0 .50 ksf TEST READINGS Load No. 9 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03690 11 60 . 00 0 . 03780 2 0 . 10 0 . 03760 12 120 . 00 0 . 03780 3 0 . 25 0 . 03765 13 240 . 00 0 . 03780 4 0 . 50 0 . 03770 5 1 . 00 0 . 03770 6 2 . 00 0 . 03770 7 4 . 00 0 . 03770 8 8 . 00 0 . 03770 9 15 . 00 0 . 03775 10 30 . 00 0 . 03780 Void Ratio = 1. 861 Compression = 3 . 5 % >>> CALCULATED USING D100 Do = 0 . 03502 D90 = 0 . 03520 D100 = 0 . 03522 Cv at 0.7 min. = 0 . 0050 in. 2/sec. -- Summit Engineering Pressure: 1 .00 ksf TEST READINGS Load No. 10 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03780 11 60 . 00 0 . 04100 2 0 . 10 0 . 04050 3 0 . 25 0 . 04060 4 0 . 50 0. 04070 5 1. 00 0 . 04070 6 2 . 00 0 . 04070 7 4 . 00 0 . 04070 8 8 . 00 0 . 04080 9 15. 00 0 . 04090 10 30 . 00 0 . 04090 Void Ratio = 1 . 853 Compression = 3 . 8 % >>> CALCULATED USING D100 D0 = 0 . 03734 D90 = 0 . 03770 D100 = 0 . 03774 C. at 0.7 min. = 0 . 0050 in. 2/sec. Pressure: 2 . 00 ksf TEST READINGS Load No. 11 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 04100 it 60 . 00 0 . 04960 2 0 . 10 0 . 04750 12 120 . 00 0 . 04990 3 0 . 25 0 . 04790 4 0 . 50 0 . 04810 5 1 . 00 0 . 04830 6 2 . 00 0 . 04860 7 4 . 00 0 . 04870 8 8 . 00 0 . 04890 9 15 . 00 0 . 04910 10 30 . 00 0 . 04930 Void Ratio = 1 . 834 Compression = 4 . 4 % >>> CALCULATED USING D100 D0 = 0 . 04291 D90 = 0 . 04415 D100 = 0 . 04429 Cv at 0 . 4 min. = 0 . 0076 in. 2/sec. Pressure: 4 . 00 ksf TEST READINGS Load No. 12 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 04990 it 60 . 00 0 . 09510 2 0 . 10 0 . 08050 12 120. 00 0 . 09590 3 0 . 25 0 . 08580 4 0 . 50 0 . 08800 5 1 . 00 0 . 08950 6 2 . 00 0 . 09070 7 4 . 00 0 . 09180 8 8 . 00 0 . 09270 9 15 . 00 0. 09350 10 30 . 00 0 . 09430 Void Ratio = 1. 715 Compression = 8 . 4 % >>> CALCULATED USING D100 D0 = 0 . 06932 D90 = 0 . 08274 D100 = 0 . 08423 C. at 0 .7 min. = 0 . 0046 in. 2/sec. - Summit Engineering Pressure: 8 .00 ksf TEST READINGS Load No. 13 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 09590 11 60 . 00 0 . 16800 2 0 . 10 0 . 13670 12 120 . 00 0 . 16910 3 0 . 25 0 . 15170 13 240 . 00 0 . 17000 4 0 . 50 0 . 15720 14 480 . 00 0 . 17090 5 1 . 00 0 . 16020 15 720 . 00 0 . 17130 6 2 . 00 0 . 16210 16 960 . 00 0 . 17180 7 4 . 00 0 . 16350 8 8 . 00 0 . 16480 9 15. 00 0 . 16590 10 30 . 00 0 . 16710 Void Ratio = 1. 508 Compression = 15 . 4 % >>> CALCULATED USING D100 D0 = 0 . 11438 D90 = 0 . 15031 D100 = 0 . 15431 Cv at 0. 6 min. = 0 . 0042 in. 2/sec. Pressure: 16.00 ksf TEST READINGS Load No. 14 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 17180 11 60 . 00 0 . 25310 2 0 . 10 0 . 21530 12 120 . 00 0 . 25430 3 0 . 25 0 . 23100 4 0 . 50 0 . 23910 5 1 . 00 0 . 24350 6 2 . 00 0 . 24620 7 4 . 00 0 . 24800 8 8 . 00 0 . 24950 9 15 . 00 0 . 25070 10 30 . 00 0 . 25190 Void Ratio = 1 . 268 Compression = 23 . 5 % >>> CALCULATED USING D100 D0 = 0 . 18748 D90 = 0 . 23047 D100 = 0 . 23524 Cv at 0 .7 min. = 0 . 0033 in. 2/sec. Pressure: 32 .00 ksf TEST READINGS Load No. 15 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 25430 11 60 . 00 0 . 34090 2 0 . 10 0 . 27500 12 120 . 00 0 . 34120 3 0 . 25 0 . 30240 4 0 . 50 0 . 31870 5 1 . 00 0 . 32820 6 2 . 00 0 . 33280 7 4 . 00 0 . 33540 8 8 . 00 0 . 33700 9 15 . 00 0 . 33830 10 30 . 00 0 . 33950 Void Ratio = 1 . 018 Compression = 31 . 9 % >>> CALCULATED USING D100 D0 = 0 . 22998 D90 = 0 . 31049 D100 = 0 . 31944 Cv at 0. 7 min. = 0 . 0027 in. 2/sec. Summit Engineering Pressure: 16.00 ksf TEST READINGS Load No. 16 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 34120 it 60 . 00 0 . 33630 2 0 . 10 0 . 33750 12 120 . 00 0 . 33630 3 0 . 25 0 . 33710 4 0 . 50 0 . 33700 5 1. 00 0 . 33690 6 2 . 00 0 . 33680 7 4 . 00 0 . 33670 8 8 . 00 0 . 33670 9 15. 00 0 . 33660 10 30 . 00 0 . 33640 Void Ratio = 1 . 001 Compression = 32 . 5 % >>> CALCULATED USING D100 D0 = 0. 32624 D90 = 0 . 32537 D100 = 0 . 32527 Cv at 0 . 6 min. = 0 . 0026 in. 2/sec. Pressure: 4. 00 ksf TEST READINGS Load No. 17 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 33630 11 60 . 00 0 . 31780 2 0 . 10 0 . 32520 12 120 . 00 0 . 31760 3 0 . 25 0 . 32340 13 240 . 00 0 . 31740 4 0 . 50 0 . 32180 14 480 . 00 0 . 31710 5 1 . 00 0 . 32030 15 720 . 00 0 . 31700 6 2 . 00 0 . 31950 7 4 . 00 0 . 31910 8 8 . 00 0 . 31870 9 15. 00 0 . 31840 10 30 . 00 0 . 31820 Void Ratio = 1. 045 Compression = 31 . 0 % >>> CALCULATED USING D100 D0 = 0 . 31835 D90 = 0 . 31119 D100 = 0 . 31039 Cv at 1 .3 min. = 0 . 0012 in. 2/sec. Pressure: 1.00 ksf TEST READINGS Load No. 18 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 31700 11 60 . 00 0 . 29830 2 0 . 10 0 . 31150 12 120 . 00 0 . 29770 3 0 . 25 0 . 30890 4 0 . 50 0. 30650 5 1 . 00 0 . 30400 6 2 . 00 0 . 30210 7 4 . 00 0 . 30080 8 8 . 00 0 . 30000 9 15 . 00 0 . 29940 10 30 . 00 0 . 29880 Void Ratio = 1. 090 Compression = 29 . 5 % >>> CALCULATED USING D100 D0 = 0 . 30789 D90 = 0 . 29624 D100 = 0 . 29495 Cv at 1 .5 min. = 0 . 0011 in. 2/sec. - - - Summit Engineering Pressure: 0 .25 ksf TEST READINGS Load No. 19 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 29770 11 60 . 00 0 . 28270 2 0 . 10 0. 29490 12 120 . 00 0 . 28180 3 0 . 25 0 . 29350 13 240 . 00 0 . 28100 4 0 . 50 0 . 29200 14 480 . 00 0 .28020 5 1. 00 0 . 29030 15 720 . 00 0 .27970 6 2 . 00 0. 28830 16 960 . 00 0 . 27940 7 4 . 00 0 . 28670 17 1440 . 00 0. 27920 8 8 . 00 0 . 28550 9 15 . 00 0 . 28450 10 30 . 00 0 . 28350 Void Ratio = 1. 134 Compression = 28 . 0 % >>> CALCULATED USING D100 D0 = 0 . 29058 D90 = 0 . 28119 D100 = 0. 28015 Cv at 4 . 9 min. = 0 . 0004 in. 2/sec. Summit Engineering Consolidation Test Report -4 4 i 8 c 12 CU 16 N U a 20 24 28 32 36 .1 .2 .5 1 2 5 10 20 Applied Pressure- ksf Coefficients of Consolidation and Secondary Consolidation No. Load Cv Ca N0. Load Cv Ca No. Load Cv Ca (ksf) (in.2/sec.) (ksf) (in.2/sec.) (ksf) (in.2/sec.) 2 0.25 0.0001 12 4.00 0.0045 3 0.50 0.0006 13 8.00 0.0039 4 1.00 0.0007 14 16.00 0.0056 5 2.00 0.0047 15 32.00 0.0026 6 1.00 0.0027 16 16.00 ' 0.0041 7 0.50 0.0008 17 4.00 0.0010 8 0.25 0.0036 18 1.00 0.0010 9 0.50 0.0003 19 0.25 0.0003 10 1.00 0.0026 11 1 2.00 0.0016 Natural Dry Dens. LL PI Sp. Overburden Pc cc Cr Swell Press. Heave e° Sat. Moist. (pcf) Gr. (ksf) (ksf) (ksf) % 93.4% 66.7% 57.6 63 3 2.70 3.38 0.85 1 0.05 1.927 MATERIAL DESCRIPTION USCS AASHTO Orange-Brown Micaceous Sandy Elastic Silt MH A-5(3) Project No. 6507.1,0006 Client: HDR Engineering Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-3 @ 21'-23' Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-3 Q 2V-23' 1sa Aso .0023 Load#2 0067 Load#3 0.25 ksf 0.50 ksf .0024 C,@ 25.41 min= .0069 [C4,,@ 5.46 min.= O.00OI irr.2rsec. 005 in.2152 0025 .0071 .0026 -0073 .0027 --.0075 c c c c .0028 .0077 of of m .0029 .0079 .0030 .0081 .0031 .0083 .0032 .0085 L-- -L- 5C .0033L 000 1.25 2.50 3-75 5.00 $25 7.50 8-75 10.00 11.25 12.50 .0087 0.00 1.2$ 230 3.75 5.00 625 7.50 0.75 10.00 11 25 i 2. Square Root of Elapsed Time(min) Square Root of Elapsed Time(min.) 'so rso 0157 Load#4 029 Load#5 1.00 ksf 2.00 ksf @001s1 m in= v $ . . 010007 in.2/sec. C0047 in 21sea. .0165 .031 0169 .032 -- 0173 .033 -- c � C C .0177 .034 0181 .035 .0185 .036 .0189 .037 .0193 - .038 '0197 0 4 8 12 18 20 2z 28 32 SE 40 '039 0 2 4 6 a 10 12 14 16 18 20 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County, North Carolina Location: GT2I-19,ST-3 @ 21'-23- 190 too Load#6 .03329 Load#7 1.00 ksf 0.50 ksf Cv @ 1.22 min.= .03314 Cy @ 4.24 min= 0.0027 i0/=. 0.0008 in.2/Sec. 0384 .03299 .0363 .03284 .0362 03269 c c c S .0361 .03254 of of m m ° .0360 ° .03239 .0359 .03224 .0358 .03209 .0357 .03194 .0356 0 2 4 5 8 10 12 14 is 18 20 .03179 0.00 1.25 2.50 3.75 5.00 0.25 7.50 8.75 10.00 11-25 12.5 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) �90 190 0299 Load#8 .028442 Load#9 0.25 ksf 0.50 ksf .0297 Cv U 0.93 min,= .028517 Cv @ 10.59 min.= 0.0036 in.2/sec. 0.0003 in.2/sec. .0295 028592 .0293 .028667 --.0291 --.028742 C � C C .0289 {gyp .028817 w ° .0287 ° .028692 0285 .028967 .0283 .onO42 .0281 .029117 0279 0 2 5 a 10 12 1.1 15 18 20 •029192 0 3 1 9 12 15 18 21 24 27 30 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19,ST-3 @ 211-231 tso 1so .0314 Load#10 .0380 Load#11 1.00 ksf 2.00 ksf 0315 - Cv @ 1.25 min= .0383 Cv @ 2.03 min.= 0A026 im21gee, 0.0016 in-21see. .0316 .0386 .0317 -0389 -0318 ^.0392 c c -0310 m -0395 .0320 .0399 - .0321 .0401 .0322 •0404 1 .0323 .0407 -0324 0.00 1.25 2.60 3-75 5.00 6.25 7.50 8.75 10.00 11-25 12.50 .0410 0 2 4 8 a 10 12 .14 16 18 Z�J Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) too 190 06£5 Load#12 .128 Load#13 4.00 ksf 8.00 ksf .0690 Cv @ 0.67 min= 133 Cv @ 0.66 min. 0-0045 in.2)=. 0.0039 id inc. .0715 .135 .0740 1 .-.0765 --.143 c 0790 m •153 m 6 .0815 -158 .0840 .163 .0865 -168 .0890 179 09150 2 4 6 8 10 12 1.1 i8 18 20 .1780 4 8 12 16 20 24 28 32 36 40 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.1,0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Location: GT21-19, ST-3 @ 21'-23' (90 .17 Load#14 2277 Load#15 16.00 ksf 32.00 ksf 18 Cv @?0.39 min.= 2402 Cv @ 0.69 min= 0.0056 in.2lsec. 0.0026 in.2;sec. I 19 .2527 20 z652 .-..21 --.2777 c C c W 22 W .2902 D W W .23 .3027 .24 .3152 25 .3277 .26 .3402 �~ 27 0 2 4 a 8 10 12 14 16 18 20 .3527 0 2 a 6 $ 10 12 14 1$ 18 20 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) t90 190 .3391 Load#16 .3304 Load#]7 16.00 ksf 4.00 ksf .3388 Cv @ 0.38 min.= .3289 Cv®1.55 min.- 0,0U41 in.2;scc. 0.0010 in?;3CC_ .3385 .3274 .3382 3259 - .3379 .3244 c 5 c c W .3376 .3229 .3373 .3214 .3370 .3199 V .3367 3184 .3364 .3168 3367 - 4 6 8 10 12 14 18 18 20 .3154 0 4 8 12 16 20 24 28 32 36 40 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure Dial Reading vs. Time Project No.: 6507.L0006 Project: PLI Concentrator Definitive Feasibility Study Gaston County, North Carolina Location: GT21-19,ST-3 @ 21'-23' tyq �90 .322 Load#18 302 Load#19 1.00 ksf 0.25 ksf 319 Cv @�1.77 min= .299 Cv @ 5.20 min.- 0 0010 in 2/sec• 0.0003 in 2/sec. .316 .296 .313 .293 .310 --290 c 6 c_ c .307 .287 of .304 .284 .301 .281 .298 27a .295 .275 .292 0 2 4 6 a 10 12 14 16 15 20 272 0 5 10 15 20 25 30 35 40 45 50 Square Root of Elapsed Time(min.) Square Root of Elapsed Time(min.) Summit Engineering Ft. Mill, South Carolina Figure CONSOLIDATION TEST DATA Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County, North Carolina Project Number: 6507 .L0006 Sample Data Source: Sample No. : Elev. or Depth: Sample Length(in./cm. ) : Location: GT21-19, ST-3 @ 21 ' -2-':; ' Description: Orange-Brown Micaceous Sandy Elastic Silt Liquid Limit: 63 Plasticity Index: 3 USCS: MH AASHTO: A-5 (3) Figure No. : Testing Remarks : Test Specimen Data TOTAL SAMPLE BEFORE TEST AFTER TEST Wet w+t = 123 . 68 g. Consolidometer # = 3 Wet w+t = 107 . 81 g. Dry w+t = 74 . 19 g. Dry w+t = 74 . 19 g. Tare Wt. = . 00 g. Spec. Gravity = 2 . 70 Tare Wt. = . 00 g. Height = 1 . 00 in. Height = 1 . 00 in. Diameter = 2 . 50 in. Diameter = 2 . 50 in. Weight = 123. 68 g. Defl. Table = 3 Moisture = 66. 7 % Ht. Solids = 0 . 3416 in. Moisture = 45 . 3 % Wet Den. = 96. 0 pcf Dry Wt. = 74 . 19 g. Dry Wt. = 74 . 19 g. * Dry Den. = 57 . 6 pcf Void Ratio = 1 . 927 Void Ratio = 1. 099 Saturation = 93 . 4 % * Final dry weight used in calculations End-of-Load Summary Pressure Final Machine Cv Ca Void % Compression (ksf) Dial (in. ) Defl. (in. ) (in.2/sec. ) Ratio /Swell start 0 . 00000 1 . 927 0 . 10 0 . 00000 0 . 00000 1. 927 0 . 0 Swell 0 . 25 0 . 00360 0 . 00040 0 . 0001 1 . 918* 0 . 3 Comprs . * 0 . 50 0 . 00930 0 . 00090 0 . 0006 1 . 903* 0 . 8 Comprs . * 1. 00 0 . 02080 0 . 00190 0 . 0007 1 . 876* 1 . 8 Comprs . * 2 . 00 0 . 04110 0 . 00330 0 . 0047 1 . 825* 3 . 5 Comprs . * 1 . 00 0 . 03870 0 . 00290 0 . 0027 1 . 823* 3 . 6 Comprs . * 0 . 50 0 . 03480 0 . 00270 0 . 0008 1 . 832* 3. 2 Comprs . * 0 . 25 0 . 03040 0 . 00230 0 . 0036 1 . 843* 2 . 9 Comprs . * 0 . 50 0 . 03130 0 . 00230 0 . 0003 1 . 843* 2 . 9 Comprs. * 1 . 00 0 . 03470 0 . 00240 0 . 0026 1 . 834* 3. 2 Comprs . * 2 . 00 0 . 04390 0 . 00330 0 . 0016 1 . 812* 3. 9 Comprs . * 4 . 00 0 . 09370 0 . 00530 0 . 0045 1 . 690* 8 . 1 Comprs . * 8 . 00 0 . 17610 0 . 00740 0 . 0039 1 . 468* 15. 7 Comprs . * -- - Summit Engineering - Pressure Final Machine Cv Ca Void % Compression (ksf) Dial (in. ) Defl. (in. ) (in.2/sec. ) Ratio /Swell 16. 00 0 . 26360 0 . 00970 0 . 0056 1 . 217* 24 . 3 Comprs. * 32 . 00 0 . 35240 0 . 01200 0 . 0026 0 . 961* 33 . 0 Comprs. * 16. 00 0 . 34750 0 . 01130 0 . 0041 0 . 942* 33. 7 Comprs . * 4 . 00 0 . 32590 0 . 00900 0 . 0010 0 . 993* 31 . 9 Comprs . * 1 . 00 0 . 30280 0 . 00690 0 . 0010 1 . 048* 30 . 0 Comprs . * 0 . 25 0 . 28060 0 . 00470 0 . 0003 1. 099* 28 . 3 Comprs . * *CALCULATED USING D100 INSTEAD OF FINAL READING Cc = 0 . 85 Pc = 3 . 38 ksf Cr = 0 . 05 Pressure: 0.25 ksf TEST READINGS Load No. 2 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 00000 11 60 . 00 0 . 00360 2 0 . 10 0 . 00290 3 0 . 25 0 . 00290 4 0 . 50 0 . 00295 5 1 . 00 0 . 00300 6 2 . 00 0 . 00300 7 4 . 00 0 . 00310 8 8 . 00 0 . 00320 9 15 . 00 0 . 00340 10 30 . 00 0 . 00350 Void Ratio = 1. 918 Compression = 0 . 3 % >>> CALCULATED USING D100 DO = 0 . 00236 D90 = 0 . 00307 D100 = 0 . 00315 Cv at 25.4 min. 0 . 0001 in. 2/sec. Pressure: 0 .50 ksf TEST READINGS Load No. 3 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 00360 11 60 . 00 0 . 00930 2 0 . 10 0 . 00820 3 0 . 25 0 . 00830 4 0 . 50 0 . 00840 5 1. 00 0 . 00850 6 2 . 00 0 . 00880 7 4 . 00 0 . 00900 8 8 . 00 0 . 00910 9 15 . 00 0 . 00920 10 30 . 00 0 . 00925 Void Ratio = 1. 903 Compression = 0 . 8 % >>> CALCULATED USING D100 DO = 0 . 00715 D90 = 0 . 00814 D100 = 0 . 00825 Cv at 5 .5 min. = 0 . 0006 in. 2/sec. Summit Engineering Pressure: 1 .00 ksf TEST READINGS Load No. 4 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 00930 11 60 . 00 0 . 02020 2 0 . 10 0. 01800 12 120 . 00 0 . 02030 3 0 . 25 0. 01840 13 240 . 00 0 . 02040 4 0 . 50 0 . 01870 14 480 . 00 0 . 02050 5 1 . 00 0 . 01880 15 720 . 00 0 . 02080 6 2 . 00 0 . 01900 7 4 . 00 0. 01930 8 8 . 00 0 . 01950 9 15 . 00 0 . 01960 10 30 . 00 0 . 01990 Void Ratio = 1 . 876 Compression = 1 . 8 % >>> CALCULATED USING D100 D0 = 0 . 01612 D90 = 0 . 01746 D100 = 0 . 01761 Cv at 5 .0 min. = 0 . 0007 in. 2/sec. Pressure: 2 .00 ksf TEST READINGS Load No. 5 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 02080 11 60 . 00 0 . 04100 2 0 . 10 0 . 03600 12 120 . 00 0 . 04110 3 0 . 25 0 . 03710 4 0 . 50 0 . 03770 5 1 . 00 0. 03810 6 2 . 00 0 . 03870 7 4 . 00 0 . 03920 8 8 . 00 0 . 03960 9 15 . 00 0 . 04010 10 30 . 00 0 . 04040 Void Ratio = 1 . 825 Compression = 3 . 5 % >>> CALCULATED USING D100 D0 = 0 . 03144 D90 = 0 . 03457 D100 = 0 . 03492 Cv at 0.7 min. = 0 . 0047 in. 2/sec. Pressure: 1 . 00 ksf TEST READINGS Load No. 6 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 04110 11 60 . 00 0 . 03870 2 0 . 10 0 . 03920 12 120 . 00 0 . 03870 3 0 . 25 0 . 03910 4 0 . 50 0 . 03890 5 1 . 00 0 . 03880 6 2 . 00 0 . 03880 7 4 . 00 0 . 03880 8 8 . 00 0 . 03880 9 15. 00 0 . 03880 10 30 . 00 0 . 03870 Void Ratio = 1 . 823 Compression = 3 . 6 % >>> CALCULATED USING D100 D0 = 0 . 03648 D90 = 0 . 03590 D100 = 0 . 03584 Cv at 1 .2 min. = 0 . 0027 in. 2/sec. Summit Engineering Pressure: 0.50 ksf TEST READINGS Load No. 7 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03870 11 60 . 00 0 . 03480 2 0 . 10 0 . 03560 3 0 . 25 0 . 03550 4 0 . 50 0 . 03550 5 1. 00 0 . 03540 6 2 . 00 0 . 03530 7 4 . 00 0 . 03520 8 8 . 00 0 . 03510 9 15 . 00 0 . 03490 10 30 . 00 0 . 03480 Void Ratio = 1 . 832 Compression = 3 . 2 % >>> CALCULATED USING D100 D0 = 0 . 03297 D90 = 0 . 03249 D100 = 0 . 03244 C. at 4.2 min. = 0 . 0008 in. 2/sec. Pressure: 0 .25 ksf TEST READINGS Load No. 8 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03480 11 60 . 00 0 . 03050 2 0 . 10 0 . 03160 12 120 . 00 0 . 03040 3 0 . 25 0 . 03150 4 0 . 50 0 . 03130 5 1 . 00 0 . 03120 6 2 . 00 0 . 03120 7 4 . 00 0 . 03110 8 8 . 00 0 . 03090 9 15 . 00 0 . 03080 10 30 . 00 0 . 03070 Void Ratio = 1 . 843 Compression = 2 . 9 % >>> CALCULATED USING D100 D0 = 0 . 02956 D90 = 0 . 02891 D100 = 0 . 02884 Cv at 0. 9 min. = 0 . 0036 in. 2/sec. Pressure: 0 .50 ksf TEST READINGS Load No. 9 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03040 11 60 . 00 0 . 03130 2 0 . 10 0 . 03090 12 120. 00 0 . 03130 3 0 . 25 0 . 03095 13 240. 00 0 . 03130 4 0 . 50 0 . 03100 14 480. 00 0 . 03130 5 1 . 00 0 . 03100 6 2 . 00 0 . 03105 7 4 . 00 0 . 03110 8 8 . 00 0 . 03120 9 15 . 00 0 . 03120 10 30 . 00 0 . 03120 Void Ratio = 1 . 843 Compression = 2 . 9 % >>> CALCULATED USING D100 D0 = 0 . 02859 D90 = 0 . 02890 D100 = 0. 02893 C. at 10 . 6 min. 0 . 0003 in. 2/sec. -- -- Summit Engineering Pressure: 1 .00 ksf TEST READINGS Load No. 10 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03130 11 60 . 00 0 . 03470 2 0 . 10 0 . 03410 3 0 . 25 0 . 03420 4 0 . 50 0 . 03430 5 1 . 00 0 . 03440 6 2 . 00 0 . 03440 7 4 . 00 0 . 03440 8 8 . 00 0 . 03450 9 15 . 00 0 . 03460 10 30 . 00 0 . 03470 Void Ratio = 1. 834 Compression = 3 . 2 % >>> CALCULATED USING D100 D0 = 0 . 03157 D90 = 0. 03200 D100 = 0 . 03205 Cv at 1 .3 min. = 0 . 0026 in. 2/sec. Pressure: 2 . 00 ksf TEST READINGS Load No. 11 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 03470 11 60 . 00 0 . 04360 2 0 . 10 0 . 04170 12 120 . 00 0 . 04390 3 0 . 25 0 . 04190 4 0 . 50 0 . 04200 5 1 . 00 0 . 04240 6 2 . 00 0 . 04260 7 4 . 00 0 . 04270 8 8 . 00 0 . 04280 9 15. 00 0 . 04320 10 30 . 00 0 . 04340 Void Ratio = 1 . 812 Compression = 3 . 9 % >>> CALCULATED USING D100 D0 = 0 . 03808 D90 = 0 . 03930 D100 = 0 . 03944 Cv at 2 .0 min. = 0 . 0016 in. 2/sec. Pressure: 4 . 00 ksf TEST READINGS Load No. 12 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 04390 11 60 . 00 0 . 09280 2 0 . 10 0 . 07870 12 120 . 00 0 . 09370 3 0 . 25 0 . 08290 4 0 . 50 0 . 08470 5 1. 00 0 . 08600 6 2 . 00 0 . 08700 7 4 . 00 0 . 08840 8 8 . 00 0 . 08950 9 15 . 00 0 . 09040 10 30 . 00 0 . 09160 Void Ratio = 1. 690 Compression = 8 . 1 % >>> CALCULATED USING D100 D0 = 0 . 06908 D90 = 0 . 07989 D100 = 0 . 08109 Cv at 0 .7 min. = 0 . 0045 in. 2/sec. -- - -- Summit Engineering Pressure: 8 . 00 ksf TEST READINGS Load No. 13 No. Elapsed Dial No_ Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 09370 11 60 . 00 0 . 17220 2 0 . 10 0 . 14910 12 120 . 00 0 . 17320 3 0 . 25 0 . 15770 13 240 . 00 0 . 17440 4 0 . 50 0 . 16110 14 480 . 00 0 . 17520 5 1 . 00 0 . 16350 15 720 . 00 0 . 17560 6 2 . 00 0 . 16520 16 960 . 00 0 . 17610 7 4 . 00 0 . 16690 8 8 . 00 0 . 16830 9 15 . 00 0 . 16960 10 30 . 00 0 . 17080 Void Ratio = 1 . 468 Compression = 15 . 7 % >>> CALCULATED USING D100 D0 = 0 . 13313 D90 = 0 . 15454 D100 = 0 . 15692 Cv at 0.7 min. = 0 . 0039 in. 2/sec. Pressure: 16.00 ksf TEST READINGS Load No. 14 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0. 17610 11 60 . 00 0 . 26250 2 0 . 10 0 . 22240 12 120 . 00 0 . 26360 3 0 . 25 0 . 24130 4 0 . 50 0 . 24900 5 1 . 00 0 . 25300 6 2 . 00 0. 25550 7 4 . 00 0. 25720 8 8 . 00 0 . 25880 9 15 . 00 0 . 26010 10 30 . 00 0 . 26120 Void Ratio = 1 . 217 Compression = 24 . 3 % >>> CALCULATED USING D100 D0 = 0 . 18018 D90 = 0 . 23637 D100 = 0 . 24262 Cv at 0 . 4 min. = 0 . 0056 in. 2/sec. Pressure: 32 .00 ksf TEST READINGS Load No. 15 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0. 26360 11 60 . 00 0 . 35220 2 0 . 10 0 . 28500 12 120 . 00 0 . 35240 3 0 . 25 0 . 31370 4 0 . 50 0 . 32920 5 1 . 00 0 . 33880 6 2 . 00 0 . 34370 7 4 . 00 0 . 34650 8 8 . 00 0 . 34830 9 15 . 00 0 . 34970 10 30 . 00 0. 35080 Void Ratio = 0 . 961 Compression = 33 . 0 % >>> CALCULATED USING D100 D0 = 0 . 24029 D90 = 0 . 32118 D100 = 0 . 33017 Cv at 0 .7 min. = 0 . 0026 in. 2/sec. - - -- Summit Engineering Pressure: 16.00 ksf TEST READINGS Load No. 16 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 35240 11 60 . 00 0 . 34750 2 0 . 10 0 . 34890 12 120 . 00 0 . 34750 3 0 . 25 0 . 34830 4 0 . 50 0 . 34810 5 1 . 00 0 . 34800 6 2 . 00 0 . 34800 7 4 . 00 0 . 34790 8 8 . 00 0 . 34780 9 15 . 00 0 . 34760 10 30 . 00 0 . 34750 Void Ratio = 0 . 942 Compression = 33 . 7 % >>> CALCULATED USING D100 Do = 0 . 33863 D90 = 0 . 33689 D100 = 0 . 33670 Cv at 0 .4 min. = 0 . 0041 in. 2/sec. Pressure: 4.00 ksf TEST READINGS Load No. 17 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 34750 11 60 . 00 0 . 32650 2 0 . 10 0 . 33540 12 120 . 00 0 . 32630 3 0 . 25 0 . 33360 13 240 . 00 0 . 32600 4 0 . 50 0 . 33170 14 480 . 00 0 . 32590 5 1 . 00 0 . 32990 15 720 . 00 0 . 32590 6 2 . 00 0 . 32840 7 4 . 00 0 . 32770 8 8 . 00 0 . 32740 9 15. 00 0 . 32710 10 30 . 00 0 . 32680 Void Ratio = 0 . 993 Compression = 31 . 9 % >>> CALCULATED USING D100 D0 = 0 . 32872 D90 = 0 . 32001 D100 = 0 . 31904 Cv at 1 . 6 min. = 0 . 0010 in. 2/sec. Pressure: 1 . 00 ksf TEST READINGS Load No. 18 No. Elapsed Dial No. Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 32590 11 60 . 00 0 . 30350 2 0 . 10 0 . 32020 12 120 . 00 0 . 30280 3 0 . 25 0 . 31720 4 0 . 50 0 . 31440 5 1 . 00 0 . 31130 6 2 . 00 0 . 30840 7 4 . 00 0 . 30680 8 8 . 00 0 . 30580 9 15 . 00 0 . 30490 10 30 . 00 0 . 30400 Void Ratio = 1 . 048 Compression = 30 . 0 % >>> CALCULATED USING D100 Do = 0 . 31702 D90 = 0 . 30210 D100 = 0. 30044 Cv at 1 .8 min. = 0 . 0010 in. 2/sec. - Summit Engineering Pressure: 0.25 ksf TEST READINGS Load No. 19 No. Elapsed Dial No_ Elapsed Dial Time Reading Time Reading 1 0 . 00 0 . 30280 11 60 . 00 0 . 28450 2 0 . 10 0 . 30020 12 120 . 00 0 . 28350 3 0 . 25 0 .29850 13 240 . 00 0 . 28270 4 0 . 50 0 . 29680 14 480 . 00 0 . 28180 5 1 . 00 0 . 29460 15 720 . 00 0 .28120 6 2 . 00 0 . 29220 16 960 . 00 0 .28090 7 4 . 00 0 . 28970 17 1440 . 00 0 . 28060 8 8 . 00 0 . 28810 9 15. 00 0 . 28680 10 30 . 00 0 . 28550 Void Ratio = 1. 099 Compression = 28 . 3 % >>> CALCULATED USING D100 D0 = 0 . 29678 D90 = 0 . 28446 D100 = 0 . 28309 C. at 5 .2 min. = 0 . 0003 in. 2/sec. Summit Engineering LIQUID AND PLASTIC LIMITS TEST REPORT 60 / Dashed line indicates the approximate upper limit boundary for natural soils / / / 50 / / 01, / 40 / X / Z / U 30 -- U / g / a / � / Q 20 — 0 10 L- L ML or OL MH or OH 0 • 0 10 20 30 40 50 60 70 80 90 100 110 LIQUID LIMIT MATERIAL DESCRIPTION LL PL PI %<#40 %<#200 USCS • Light-Brown Micaceous Silty Sand 59 58 1 84.0 36.9 SM ■ Light-Brown Micaceous Silty Sand 68 64 4 90.4 44.6 SM • Orange-Brown Micaceous Sandy Elastic Silt 63 60 3 96.5 52.8 MH I — Project No. 6507.L0006 Client: HDR Engineering Remarks: Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina •Location: GT21-19,ST-1 @ 15'-17' ■Location: GT21-19,ST-2 @ 18'-20' •Location: GT21-19,ST-3 @ 21'-23' Summit Engineering Ft. Mill South Carolina Figure Tested By: _FG Checked By: MH Particle Size Distribution Report C C O O O C C C C C C pp O N M O (00 0 V N (0 f0 N \ # # # # # # # 100 I I 1 1 1 I I I I I I I I so I I 11 1 I l I I I I I I I I I 11 1 I I I I I k k k 80 , I ! 1 I I I I I I I I 1 ! I 70 I I ! I 1 1 1 I I I I I I f I I I I l l W 60 Z 50 I I I I I ! I I k I U I I I I I I I I I I I W 40 a I I I I I I I I l l l l 30 I I I l l I I I I I I I I I 20 I i 11 1 1 1 I I I l l l l 10 I I I I I I I I I I I I I I 0 I I I I I IIJ 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %+3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.9 15.1 47.1 1 36.9 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Light-Brown Micaceous Silty Sand 0.375 100.0 #4 100.0 #10 99.1 # 939 Atterbsrg Limits 20 . _ # 0 93. PL= 58 LL= 59 PI= 1 #60 70.3 Coefficients #140 44.5 D90= 0.6045 D85= 0.4468 D60= 0.1801 #200 36.9 D50= 0.1300 D30= D15= D10= Cu= Cc= Classification USCS= SM AASHTO= A-5(0) Remarks Moisture Content:61.8% K (no specification provided) Location: GT21-19,ST-1 @ 15'-17' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.1,0006 Figure Tested By: FG Checked By: MH 9 Total Effective C, ksf 0.64 0.48 de 11.7 30.0 Tan 0.21 0.58 r y 6 vi U) ca m U) 3 0 0 3 6 9 12 15 18 Total Normal Stress, ksf Effective Normal Stress, ksf --- 6 1 1 1 1Sample No. 1 2 3 Water Content, % 51.7 65.7 65.7 5 Dry Density, pcf 67.1 60.6 61.3 T Saturation, % 92.5 99.6 101.4 Z Void Ratio 1.5111 1.7803 1.7478 Y q Diameter, in. 2.867 2.867 2.865 y Height, in. 6.039 6.024 6.014 Water Content, % 55.0 62.8 55.8 c"n 3 Dry Density, pcf 67.9 62.5 67.3 o Saturation, % 100.0 100.0 100.0 f6 Void Ratio 1.4841 1.6961 1.5060 0 2 ¢ Diameter, in. 2.852 2.857 2.810 Height, in. 6.037 5.882 5.701 Strain rate, %/min. 0.07 0.07 0.07 1 Back Pressure, psi 50.00 50.00 50.00 Cell Pressure, psi 56.90 77.80 105.50 0 Fail. Stress, ksf 2.17 3.47 5.70 ❑ 5 10 15 20 Total Pore Pr., ksf 7.91 10.37 13.16 Axial Strain, % Ult. Stress, ksf Total Pore Pr., ksf Type of Test: a, Failure, ksf 2.46 4.30 7.73 CU with Pore Pressures 63 Failure, ksf 0.29 0.84 2.03 Sample Type: Shelby Tube Client: HDR Engineering Description: Light-Brown Micaceous Silty Sand Project: PLI Concentrator Definitive Feasibility Study LL= 59 PL= 58 PI= 1 Gaston County,North Carolina Assumed Specific Gravity=2.70 Location: GT21-19, ST-1 @ 15'-17' Remarks: Proj. No.: 6507.L0006 Date Sampled: 11-17-21 TRIAXIAL SHEAR TEST REPORT Summit Engineering Figure 11 Ft. Mill South Carolina Tested By: FG Checked By: MH 15 1 15 12 i 12 9 Uto ) 9 w ai n w w dU) Y d U Y 6 � 0 6 o m o ca a- '> a- > 16 3 0 3 0 0 0% 8% 16% 0% 8% 16% 15 3 15 12 12 m I / _.. 9 � � m 9 uNi a�'i w N "- N ,�. � wY 6 0 6 o m `o m a '> a '� 0 3 3 0% 8% 16% �0% 8% 160/0 6 Peak Strength Total Effective / a= 0.63 ksf 0.35 ksf / a= 11.4 deg 26.8 deg tan a= 0.20 0.51 / 4 CF / m / Y / 2 T 1 � 0 \V 0 2 4 6 8 10 12 p, ksf Stress Paths: Total Effective——— Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Location: GT21-19, ST-1 @ 15'-17' Project No.: 6507.L0006 Figure Summit Engineering Tested By: FG Checked By: MH TRIAXIAL COMPRESSION TEST 11/18/2021 CU with Pore Pressures 8:45 AM Date: 11-17-21 Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Project No.: 6507.1,0006 Location: GT21-19, ST-1 @ 15'-17' Description: Light-Brown Micaceous Silty Sand Remarks: Type of Sample: Shelby Tube Assumed Specific Gravity=2.70 LL=59 PL=58 PI=1 Test Method: ASTM D 4767 Method B Jor Specimen No. I jI Specimen Parameter Initial Saturated Consolidated Final Moisture content: Moist soil+tare,gms. 1042.380 1064.520 Moisture content: Dry soil+tare, gms. 686.940 686.940 Moisture content: Tare,gms. 0.000 0.000 Moisture,% 51.7 55.8 55.0 55.0 Moist specimen weight,gms. 1042.38 Diameter, in. 2.867 2.859 2.852 Area, in? 6.456 6.418 6.388 Height, in. 6.039 6.066 6.037 Net decrease in height, in. -0.027 0.029 Net decrease in water volume,cc. 6.000 Wet density, pcf 101.9 104.7 105.2 Dry density, pcf 67.1 67.2 67.9 Void ratio 1.5111 1.5077 1.4841 Saturation, % 92.5 100.0 100.0 Membrane modulus=0.124105 kN/cm2 Membrane thickness=0.02 cm Consolidation cell pressure=56.90 psi(8.19 ksf) Consolidation back pressure=50.00 psi(7.20 ksf) Consolidation effective confining stress=0.99 ksf Strain rate, %/min.=0.07 Fail. Stress=2.17 ksf at reading no.23 Summit Engineering Test Readings for Specimen No�T.- Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 0 0.0000 0.0 0 0.0 0.00 0.99 0.99 1.00 50.00 0.99 0.00 1 0.0030 14.5 15 0.0 0.33 0.84 1.16 1.39 51.10 1.00 0.16 2 0.0050 17.4 17 0.1 0.39 0.79 1.18 1.49 51.40 0.99 0.20 3 0.0090 26.1 26 0.1 0.59 0.68 1.26 1.87 52.20 0.97 0.29 4 0.0160 32.7 33 0.3 0.74 0.59 1.33 2.25 52.80 0.96 0.37 5 0.0210 38.3 38 0.3 0.86 0.53 1.39 2.61 53.20 0.96 0.43 6 0.0240 43.1 43 0.4 0.97 0.48 1.44 3.04 53.60 0.96 0.48 7 0.0290 47.4 47 0.5 1.06 0.43 1.50 3.46 53.90 0.96 0.53 8 0.0340 51.3 51 0.6 1.15 0.40 1.55 3.85 54.10 0.98 0.57 9 0.0400 55.1 55 0.7 1.23 0.37 1.61 4.30 54.30 0.99 0.62 10 0.0460 58.1 58 0.8 1.30 0.35 1.65 4.76 54.50 1.00 0.65 11 0.0510 61.0 61 0.8 1.36 0.33 1.69 5.12 54.60 1.01 0.68 12 0.0560 63.5 64 0.9 1.42 0.32 1.73 5.48 54.70 1.03 0.71 13 0.0590 66.0 66 1.0 1.47 0.30 1.78 5.87 54.80 1.04 0.74 14 0.0660 68.1 68 1.1 1.52 0.40 1.92 4.77 54.10 1.16 0.76 15 0.0690 69.9 70 1.1 1.56 0.37 1.93 5.16 54.30 1.15 0.78 16 0.0760 71.7 72 1.3 1.60 0.36 1.96 5.43 54.40 1.16 0.80 17 0.0810 73.7 74 1.3 1.64 0.35 1.98 5.74 54.50 1.17 0.82 18 0.0850 75.5 76 1.4 1.68 0.33 2.01 6.07 54.60 1.17 0.84 19 0.0910 77.2 77 1.5 1.71 0.33 2.05 6.17 54.60 1.19 0.86 20 0.0960 78.7 79 1.6 1.75 0.32 2.06 6.51 54.70 1.19 0.87 21 0.1010 80.1 80 1.7 1.78 0.32 2.09 6.60 54.70 1.20 0.89 22 0.1510 91.3 91 2.5 2.01 0.29 2.29 7.97 54.90 1.29 1.00 23 0.2060 99.6 100 3.4 2.17 0.29 2.46 8.53 54.90 1.37 1.08 24 0.2540 105.4 105 4.2 2.28 0.30 2.58 8.53 54.80 1.44 1.14 25 0.3050 109.3 109 5.1 2.34 0.32 2.66 8.38 54.70 1.49 1.17 26 0.3560 111.8 112 5.9 2.37 0.33 2.70 8.16 54.60 1.52 1.19 27 0.4000 113.9 114 6.6 2.40 0.35 2.74 7.94 54.50 1.54 1.20 28 0.4500 116.7 117 7.5 2.43 0.35 2.78 8.04 54.50 1.56 1.22 29 0.5000 118.6 119 8.3 2.45 0.43 2.88 6.68 53.90 1.66 1.23 30 0.5500 120.9 121 9.1 2.48 0.43 2.91 6.73 53.90 1.67 1.24 31 0.6000 122.9 123 9.9 2.49 0.50 3.00 5.95 53.40 1.75 1.25 32 0.6500 125.4 125 10.8 2.52 0.48 3.00 6.31 53.60 1.74 1.26 33 0.7000 127.4 127 11.6 2.54 0.49 3.03 6.19 53.50 1.76 1.27 34 0.7500 129.4 129 12.4 2.55 0.46 3.02 6.54 53.70 1.74 1.28 35 0.8000 131.5 132 13.3 2.57 0.49 3.06 6.25 53.50 1.78 1.29 36 0.8520 133.6 134 14.1 2.59 0.49 3.08 6.28 53.50 1.78 1.29 37 0.9010 134.7 135 14.9 2.58 0.50 3.09 6.13 53.40 1.80 1.29 Summit Engineering Specimen Parameter Initial Saturated Consolidated Final Moisture content: Moist soil+tare,gms. 1025.490 1007.640 Moisture content: Dry soil+tare,gms. 618.880 618.880 Moisture content: Tare,gms. 0.000 0.000 Moisture,% 65.7 69.2 62.8 62.8 Moist specimen weight,gms. 1025.49 Diameter, in. 2.867 2.910 2.857 Area, in? 6.456 6.652 6.411 Height, in. 6.024 6.029 5.882 Net decrease in height, in. -0.005 0.147 Net decrease in water volume,cc. 39.200 Wet density, pcf 100.5 99.4 101.8 Dry density, pcf 60.6 58.8 62.5 Void ratio 1.7803 1.8671 1.6961 Saturation, % 99.6 100.0 100.0 Test Readings for Specimen No. 2--t. Membrane modulus=0.124105 kNGi- Membrane thickness=0.02 cm Consolidation cell pressure=77.80 psi(11.20 ksf) Consolidation back pressure=50.00 psi(7.20 ksf) Consolidation effective confining stress=4.00 ksf Strain rate,%/min.=0.07 Fail. Stress=3.47 ksf at reading no. 32 Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 0 0.0000 0.0 0 0.0 0.00 4.00 4.00 1.00 50.00 4.00 0.00 1 0.0030 26.3 26 0.1 0.59 3.63 4.22 1.16 52.60 3.92 0.30 2 0.0080 41.1 41 0.1 0.92 3.36 4.28 1.27 54.50 3.82 0.46 3 0.0120 52.2 52 0.2 1.17 3.14 4.31 1.37 56.00 3.72 0.59 4 0.0190 61.4 61 0.3 1.37 3.02 4.40 1.45 56.80 3.71 0.69 5 0.0220 69.2 69 0.4 1.55 2.78 4.33 1.56 58.50 3.55 0.77 6 0.0270 75.8 76 0.5 1.69 2.64 4.33 1.64 59.50 3.48 0.85 7 0.0320 81.6 82 0.5 1.82 2.51 4.33 1.73 60.40 3.42 0.91 8 0.0380 86.4 86 0.6 1.93 2.39 4.32 1.81 61.20 3.35 0.96 9 0.0440 90.6 91 0.7 2.02 2.29 4.31 1.88 61.90 3.30 1.01 10 0.0480 94.7 95 0.8 2.11 2.20 4.31 1.96 62.50 3.26 1.05 11 0.0540 98.4 98 0.9 2.19 2.12 4.31 2.03 63.10 3.21 1.09 12 0.0580 101.9 102 1.0 2.27 2.04 4.31 2.11 63.60 3.18 1.13 13 0.0620 104.8 105 1.1 2.33 2.06 4.39 2.13 63.50 3.22 1.16 14 0.0690 107.7 108 1.2 2.39 1.90 4.29 2.26 64.60 3.10 1.20 15 0.0740 110.8 111 1.3 2.46 1.84 4.30 2.33 65.00 3.07 1.23 16 0.0790 113.2 113 1.3 2.51 1.79 4.29 2.40 65.40 3.04 1.25 17 0.0840 115.3 115 1.4 2.55 1.73 4.28 2.48 65.80 3.00 1.28 18 0.0890 117.3 117 1.5 2.59 1.68 4.28 2.54 66.10 2.98 1.30 19 0.0920 119.1 119 1.6 2.63 1.70 4.33 2.55 66.00 3.02 1.32 20 0.0970 120.8 121 1.6 2.67 1.60 4.27 2.67 66.70 2.93 1.33 21 0.1020 121.6 122 1.7 2.68 1.57 4.25 2.71 66.90 2.91 1.34 22 0.1520 134.9 135 2.6 2.95 1.31 4.26 3.25 68.70 2.79 1.48 23 0.2020 141.6 142 3.4 3.07 1.11 4.18 3.77 70.10 2.64 1.54 Summit Engineering Def. Deviator Minor Eff. Major Eff, Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 24 0.2530 146.7 147 4.3 3.15 1.05 4.20 4.00 70.50 2.63 1.58 25 0.3020 150.4 150 5.1 3.20 0.95 4.16 4.37 71.20 2.55 1.60 26 0.3540 153.5 154 6.0 3.24 0.89 4.13 4.63 71.60 2.51 1.62 27 0.4030 156.7 157 6.9 3.28 0.88 4.16 4.73 71.70 2.52 1.64 28 0.4530 160.3 160 7.7 3.32 0.86 4.19 4.85 71.80 2.53 1.66 29 0.5000 163.4 163 8.5 3.36 0.84 4.19 5.02 72.00 2.51 1.68 30 0.5510 166.3 166 9.4 3.39 0.84 4.22 5.05 72.00 2.53 1.69 31 0.6530 172.7 173 11.1 3.45 0.84 4.28 5.13 72.00 2.56 1.72 32 0.7000 175.3 175 11.9 3.47 0.84 4.30 5.15 72.00 2.57 1.73 33 0.7530 177.3 177 12.8 3.47 0.85 4.32 5.09 71.90 2.59 1.74 34 0.8020 176.8 177 13.6 3.43 0.86 4.29 4.97 71.80 2.58 1.71 35 0.8500 180.3 180 14.5 3.46 0.86 4.33 5.01 71.80 2.60 1.73 36 0.9000 179.7 180 15.3 3.42 0.89 4.31 4.83 71.60 2.60 1.71 Specimen Parameter Initial Saturated Consolidated Final Moisture content: Moist soil+tare,gms. 1034.140 972.500 Moisture content: Dry soil+tare,gms. 624.280 624.280 Moisture content: Tare, gms. 0.000 0.000 Moisture, % 65.7 72.9 55.8 55.8 Moist specimen weight,gms. 1034.14 Diameter, in. 2.865 2.977 2.810 Area, in? 6.447 6.961 6.202 Height, in. 6.014 6.018 5.701 Net decrease in height, in. -0.004 0.317 Net decrease in water volume,cc. 107.000 Wet density, pcf 101.6 98.2 104.8 Dry density, pcf 61.3 56.8 67.3 Void ratio 1.7478 1.9688 1.5060 Saturation, % 101.4 100.0 100.0 Test Readings for Sp Membrane modulus=0.124105 kN/cmZ Membrane thickness=0.02 cm Consolidation cell pressure= 105.50 psi(15.19 ksf) Consolidation back pressure=50.00 psi(7.20 ksf) Consolidation effective confining stress=7.99 ksf Strain rate, %/min.=0.07 Fail. Stress=5.70 ksf at reading no. 31 Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 0 0.0000 0.0 0 0.0 0.00 7.99 7.99 1.00 50.00 7.99 0.00 1 0.0030 25.0 25 0.1 0.58 7.69 8.27 1.08 52.10 7.98 0.29 2 0.0050 42.1 42 0.1 0.98 7.44 8.42 1.13 53.80 7.93 0.49 3 0.0100 65.3 65 0.2 1.51 7.06 8.57 1.21 56.50 7.81 0.76 4 0.0150 86.2 86 0.3 2.00 6.68 8.68 1.30 59.10 7.68 1.00 5 0.0200 103.2 103 0.4 2.39 6.35 8.74 1.38 61.40 7.54 1.19 6 0.0290 129.4 129 0.5 2.99 5.80 8.79 1.52 65.20 7.30 1.49 Summit Engineering Test Readings for • •a Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 7 0.0340 139.9 140 0.6 3.23 5.53 8.76 1.58 67.10 7.14 1.61 8 0.0390 149.2 149 0.7 3.44 5.31 8.75 1.65 68.60 7.03 1.72 9 0.0440 157.2 157 0.8 3.62 5.13 8.75 1.71 69.90 6.94 1.81 10 0.0470 164.5 165 0.8 3.79 4.94 8.73 1.77 71.20 6.83 1.89 11 0.0520 170.8 171 0.9 3.93 4.78 8.71 1.82 72.30 6.75 1.96 12 0.0570 176.7 177 1.0 4.06 4.75 8.81 1.85 72.50 6.78 2.03 13 0.0620 181.4 181 1.1 4.17 4.49 8.66 1.93 74.30 6.58 2.08 14 0.0670 186.2 186 1.2 4.27 4.38 8.65 1.98 75.10 6.51 2.14 15 0.0720 190.5 191 1.3 4.37 4.26 8.63 2.02 75.90 6.45 2.18 16 0.0770 194.3 194 1.4 4.45 4.16 8.61 2.07 76.60 6.39 2.23 17 0.0810 198.0 198 1.4 4.53 4.02 8.55 2.13 77.60 6.28 2.27 18 0.0860 201.4 201 1.5 4.61 3.93 8.54 2.17 78.20 6.23 2.30 19 0.0910 204.4 204 1.6 4.67 3.84 8.51 2.21 78.80 6.18 2.33 20 0.0970 207.5 208 1.7 4.74 3.77 8.51 2.26 79.30 6.14 2.37 21 0.1010 210.0 210 1.8 4.79 3.70 8.49 2.29 79.80 6.10 2.39 22 0.1520 230.0 230 2.7 5.20 3.08 8.28 2.69 84.10 5.68 2.60 23 0.2040 242.6 243 3.6 5.43 2.74 8.17 2.98 86.50 5.45 2.72 24 0.2530 250.3 250 4.4 5.55 2.49 8.04 3.23 88.20 5.27 2.78 25 0.3040 256.4 256 5.3 5.64 2.32 7.95 3.43 89.40 5.14 2.82 26 0.3540 261.3 261 6.2 5.69 2.23 7.92 3.55 90.00 5.08 2.84 27 0.4040 264.9 265 7.1 5.71 2.15 7.86 3.66 90.60 5.00 2.86 28 0.4500 268.1 268 7.9 5.73 2.10 7.84 3.73 90.90 4.97 2.87 29 0.5020 270.1 270 8.8 5.72 2.06 7.78 3.78 91.20 4.92 2.86 30 0.5540 272.8 273 9.7 5.72 2.04 7.76 3.80 91.30 4.90 2.86 31 0.6000 274.2 274 10.5 5.70 2.03 7.73 3.81 91.40 4.88 2.85 32 0.6540 276.0 276 11.5 5.67 2.03 7.70 3.79 91.40 4.87 2.84 33 0.7040 276.9 277 12.3 5.63 2.03 7.67 3.78 91.40 4.85 2.82 34 0.7500 275.4 275 13.2 5.55 2.02 7.57 3.75 91.50 4.79 2.78 35 0.8000 271.7 272 14.0 5.42 2.02 7.44 3.69 91.50 4.73 2.71 36 0.8510 270.0 270 14.9 5.33 2.00 7.33 3.66 91.60 4.67 2.67 37 0.9000 267.8 268 15.8 5.24 1.99 7.22 3.63 91.70 4.61 2.62 Summit Engineering Particle Size Distribution Report O O O C C C C C C pb N M f�0 F N ID 100 I I I I I I I I I I I ! I I 90 I I I I I 1 I I I I I I I I I I I ! 1 I I I I I a0 I ! I f l I I I I I I I I �p ! L II ! I I I I I I I I I I I I I I I I I I W 60 LL 1 I 1 1 1 I k I I ! I Z 50LU I I I I I I I I I I I I I i I I 0 I I I I I k I I I I W 40 I I I I I I I I I I I I I I 30 I ! I I I I ! I I I I I I I 20 I I I I I l i I I I I I l l I I I I I I I I I I I I I I 10 I I I I I I I I I I I I I I p I I I I I I I I I I I I I I 100 10 1 0.1 0.01 0.001 GRAIN SIZE-mm. %Gravel %Sand _ %Fines Coarse Fine Coarse Medium Fine Silt I Clay 0.0 0.0 0.0 0.0 9.6 1 45.8 44.6 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Light-Brown Micaceous Silty Sand 0.375 100.0 #4 100.0 #10 100.0 20 98.9 Atterberg Limits # # 0 9 .4 PL= 64 LL= 68 Pl= 4 #60 77.5 Coefficients #140 52.5 D90= 0.4166 D85= 0.3319 D60= 0.1391 #200 44.6 D50= 0.0955 Dap= D15= D10= CU= Cc= Classification USCS= SM AASHTO= A-5(2) Remarks Moisture Content:69.1% (no specification provided) Location: GT21-19,ST-2 @ 18'-20' Date: 11-17-21 Summit Engineering Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG __ Checked By: MH MEN ■■■■■■i■■■■■■■■■■Rai■■!■■1■■■■■■■■■■■■■■■■■■■■■■l�i��5!■■■■■ ■■■■■■■■!■1■■■�J1i11■■■■■1■■■■■i■■!!!■■■■■Cif■■■■■i■■■■1■■■■ ■■■■■■■■!fit■■■■1■!■C\■■■■�!��■►.�1!!!!!■tip■!■■■■■■■■■■■■■■■■■ ■■■!!■l�Gii C�J tii���r�i!4\■■■■■ri■■!i■i1!■■■■■r�■■■■■i■■■■■■■■!■■ ■■■I�C�r=ir■■■l11:■■!■■■■■.l'1■■l1■■■1■■■■■■■1■■!t�■■■■1■■■■■■f■■f■ ��-i•fll�,�[�lli7■■111[�■IEEE■■[11�■i1■■!■■■■■■■■i■!■!■■■■■■i■■■■i■!■! <rL'Irrir7■■!1►�■■■11■rrl■■■■■■■i1i��■rril■■■1■■■■■■■i■■■■1!■i■.!.!1■■■■■■! • ■tf■rih!■i■i1■11■It■ti'■■■■■■!■■■!1!!■■!■■■!!■.■i■■1!!■1■■!■i■■!■■!■i . ■■■Imm■ m■■■■■■■■■■■■ ■■■m■■�■■■■■■■■■■■■ ■M■■i5�r■�■iiiii—MOZ■M■IM water content, 61.2 57.6 67.2 MOMWIMMMOMMEEMMEEM ■!.'■■■■■■mm■■■■■■■■■ ■m■■■■■■■■■■■■■m■MM Ratio 1 • :• rA MMM■■■■MEMO■■UMMM■ • • Era■■■■■■■M■■■Mm■■■■■ mjmmmmmmmmmmmmmmmm IN Height, 6.071 •• ■■■■■■0 r���====!■■WIN■MMmGir■■■■■■■■M■■■ Content, .49■11M►■■■■■■■■■■il.f■■■■� 1■ram■■■■■�.t■■■■■■■■■■ Dry Density, ,!■.M■■■■■■■■■■■■■■■■■ Saturation, 100.0 100.0 100.0 M �M■■■■�■■■■■■■■■■�■ . . Ratio. 1 1.5025 r[�r!■rrr�>■■M■■■■■■■■■■a■ rn■�■■■■■■■■■■■■■�■M■ 5.964 5.676 /,�■■■■�■■■■■■M■■M■■■ Strain rate, 0.07 0.07 0.07 ��■■��■■■■■■■■�■■■■■ Back Pressure, psi 50.00 50.00 50.00 Fail. Stress, ksf■■■�■■■�■�■■■■■■■M 2.02 3.49 5.37 • TotalPore Pr., ksf 7.68 9.94 13.38 TotalUlt. Stress, ksf -. - 1 • • It ' Engineering PLI ConcentratorDefinitive FeasibilityStudy •: •• Gaston County, • • lina TRIAXIAL SHEAR TEST REPORT Summit Engineering SouthFt. Mill, • 15 1 15 2 12 i 12 a� a) — 9 .. g a � Y aU) 6 m `0 6 `om `0m a > 0- > a) m 3 f - 0 3 0 0 0% 8% 16 0% 8% 16% 15 3 15 4 12 i 12 a> m v0i ai 9 ( w 9 6 0 0 6 0 � .. `0 m o as a- '> 0- '5 0 3 3- of 3 - of 0 0% 8% 16% 0% 8% 16% 6 Peak Strength / Total Effective a= 0.63 ksf 0.15 ksf / a= 10.9 deg 29.3 deg / tan a= 0.19 0.56 4 / / Y / i \ 2 / 0 0 2 4 6 8 10 12 p, ksf Stress Paths: Total Effective——— Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Location: GT21-19, ST-2 @ 18'-20' Project No.: 6507.L0006 Figure Summit Engineering Tested By: FG Checked By: MH TRIAXIAL COMPRESSION TEST 11/18/2021 CU with Pore Pressures 9:11 AM Date: 11-17-21 Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Project No.: 6507.L0006 Location: GT21-19, ST-2 @ 18'-20' Description: Light-Brown Micaceous Silty Sand Remarks: Type of Sample: Shelby Tube Assumed Specific Gravity=2.70 LL=68 PL=64 PI=4 Test Method: ASTM D 4767 Method B Parameters for Specimen No. Specimen Parameter Initial Saturated Consolidated Final Moisture content: Moist soil+tare,gms. 999.520 1022.310 Moisture content: Dry soil+tare,gms. 620.110 620.110 Moisture content: Tare, gms. 0.000 0.000 Moisture,% 61.2 66.0 64.9 64.9 Moist specimen weight, gms. 999.52 Diameter, in. 2.868 2.877 2.880 Area, in? 6.460 6.502 6.517 Height, in. 5.953 5.994 5.917 Net decrease in height, in. -0.041 0.077 Net decrease in water volume, cc. 6.800 Wet density, pcf 99.0 100.6 101.0 Dry density, pcf 61.4 60.6 61.3 Void ratio 1.7440 1.7808 1.7512 Saturation, % 94.7 100.0 100.0 Test Readings for Specimen No. 1 Membrane modulus=0.124105 kN/cm2 Membrane thickness=0.02 cm Consolidation cell pressure=56.90 psi(8.19 ksf) Consolidation back pressure=50.00 psi(7.20 ksf) Consolidation effective confining stress=0.99 ksf Strain rate, %/min. =0.07 Fail.Stress=2.02 ksf at reading no.26 Summit Engineering Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 0 0.0000 0.0 0 0.0 0.00 0.99 0.99 1.00 50.00 0.99 0.00 1 0.0030 14.9 15 0.1 0.33 0.89 1.22 1.37 50.70 1.06 0.16 2 0.0050 17.7 18 0.1 0.39 0.86 1.25 1.45 50.90 1.06 0.20 3 0.0100 25.7 26 0.2 0.57 0.81 1.37 1.70 51.30 1.09 0.28 4 0.0140 31.9 32 0.2 0.70 0.75 1.45 1.94 51.70 1.10 0.35 5 0.0190 36.9 37 0.3 0.81 0.71 1.52 2.15 52.00 1.11 0.41 6 0.0240 41.1 41 0.4 0.90 0.68 1.58 2.34 52.20 1.13 0.45 7 0.0290 45.0 45 0.5 0.99 0.66 1.65 2.49 52.30 1.16 0.49 8 0.0340 48.6 49 0.6 1.07 0.63 1.70 2.69 52.50 1.17 0.53 9 0.0390 51.6 52 0.7 1.13 0.63 1.77 2.79 52.50 1.20 0.57 10 0.0450 54.2 54 0.8 1.19 0.62 1.81 2.92 52.60 1.21 0.59 11 0.0490 56.9 57 0.8 1.25 0.58 1.82 3.16 52.90 1.20 0.62 12 0.0550 59.3 59 0.9 1.30 0.56 1.86 3.31 53.00 1.21 0.65 13 0.0600 61.3 61 1.0 1.34 0.55 1.89 3.45 53.10 1.22 0.67 14 0.0650 63.1 63 1.1 1.38 0.55 1.93 3.52 53.10 1.24 0.69 15 0.0690 64.7 65 1.2 1.41 0.53 1.95 3.65 53.20 1.24 0.71 16 0.0740 66.3 66 1.3 1.45 0.52 1.97 3.79 53.30 1.24 0.72 17 0.0800 67.9 68 1.4 1.48 0.52 2.00 3.86 53.30 1.26 0.74 18 0.0850 69.5 70 1.4 1.51 0.52 2.03 3.92 53.30 1.28 0.76 19 0.0900 70.5 71 1.5 1.53 0.53 2.07 3.88 53.20 1.30 0.77 20 0.0950 71.8 72 1.6 1.56 0.52 2.08 4.01 53.30 1.30 0.78 21 0.1000 72.8 73 1.7 1.58 0.50 2.09 4.14 53.40 1.29 0.79 22 0.1500 81.2 81 2.5 1.75 0.49 2.24 4.57 53.50 1.36 0.87 23 0.2000 86.7 87 3.4 1.85 0.50 2.36 4.67 53.40 1.43 0.93 24 0.2500 90.7 91 4.2 1.92 0.52 2.44 4.70 53.30 1.48 0.96 25 0.3000 94.3 94 5.1 1.98 0.52 2.50 4.82 53.30 1.51 0.99 26 0.3500 97.1 97 5.9 2.02 0.52 2.54 4.89 53.30 1.53 1.01 27 0.4010 99.8 100 6.8 2.06 0.53 2.59 4.86 53.20 1.56 1.03 28 0.4500 102.1 102 7.6 2.08 0.55 2.63 4.81 53.10 1.59 1.04 29 0.5000 104.4 104 8.5 2.11 0.56 2.67 4.76 53.00 1.62 1.06 30 0.5510 106.5 107 9.3 2.13 0.58 2.71 4.71 52.90 1.64 1.07 31 0.6010 108.3 108 10.2 2.15 0.59 2.74 4.64 52.80 1.67 1.08 32 0.6510 110.0 110 11.0 2.16 0.60 2.77 4.58 52.70 1.69 1.08 33 0.7010 111.5 112 11.8 2.17 0.60 2.78 4.59 52.70 1.69 1.09 34 0.7510 112.9 113 12.7 2.18 0.62 2.80 4.52 52.60 1.71 1.09 35 0.8010 114.1 114 13.5 2.18 0.63 2.81 4.44 52.50 1.72 1.09 36 0.8510 114.7 115 14.4 2.17 0.65 2.82 4.35 52.40 1.73 1.09 37 0.9000 115.9 116 15.2 2.17 0.66 2.83 4.28 52.30 1.75 1.09 Summit Engineering L Parameters for Specimen No. 2 Specimen Parameter Initial Saturated Consolidated Final Moisture content: Moist soil+tare, gms. 1041.800 1046.480 Moisture content: Dry soil+tare,gms. 660.940 660.940 Moisture content: Tare, gms. 0.000 0.000 Moisture, % 57.6 66.0 58.3 58.3 Moist specimen weight,gms. 1041.80 Diameter, in. 2.869 2.949 2.866 Area, in? 6.465 6.829 6.450 Height, in. 6.071 6.084 5.964 Net decrease in height, in. -0.013 0.120 Net decrease in water volume, cc. 50.500 Wet density, pcf 101.1 100.6 103.6 Dry density, pcf 64.2 60.6 65.5 Void ratio 1.6273 1.7813 1.5750 Saturation, % 95.6 100.0 100.0 Test Readings for ■ Membrane modulus=0.124105 kN/cmZ Membrane thickness=0.02 cm Consolidation cell pressure=77.80 psi(11.20 ksf) Consolidation back pressure=50.00 psi(7.20 ksf) Consolidation effective confining stress=4.00 ksf Strain rate, %/min.=0.07 Fail. Stress=3.49 ksf at reading no. 34 Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. %■ ksf ksf ksf Ratio psi ksf ksf 0 0.0000 0.0 0 0.0 0.00 4.00 4.00 1.00 50.00 4.00 0.00 1 0.0030 21.1 21 0.1 0.47 3.79 4.26 1.12 51.50 4.02 0.24 2 0.0050 29.8 30 0.1 0.66 3.67 4.34 1.18 52.30 4.00 0.33 3 0.0100 44.1 44 0.2 0.98 3.44 4.42 1.29 53.90 3.93 0.49 4 0.0140 54.6 55 0.2 1.22 3.25 4.47 1.37 55.20 3.86 0.61 5 0.0190 63.3 63 0.3 1.41 3.10 4.50 1.46 56.30 3.80 0.70 6 0.0240 70.7 71 0.4 1.57 2.95 4.52 1.53 57.30 3.74 0.79 7 0.0290 77.1 77 0.5 1.71 2.84 4.55 1.60 58.10 3.69 0.86 8 0.0340 82.6 83 0.6 1.83 2.72 4.56 1.67 58.90 3.64 0.92 9 0.0390 87.5 88 0.7 1.94 2.62 4.56 1.74 59.60 3.59 0.97 10 0.0440 92.0 92 0.7 2.04 2.53 4.57 1.80 60.20 3.55 1.02 11 0.0490 95.9 96 0.8 2.12 2.45 4.57 1.87 60.80 3.51 1.06 12 0.0540 99.4 99 0.9 2.20 2.39 4.59 1.92 61.20 3.49 1.10 13 0.0590 102.6 103 1.0 2.27 2.30 4.57 1.98 61.80 3.44 1.13 14 0.0640 105.8 106 1.1 2.34 2.25 4.58 2.04 62.20 3.41 1.17 15 0.0690 108.5 109 1.2 2.39 2.19 4.58 2.09 62.60 3.39 1.20 16 0.0740 110.9 111 1.2 2.45 2.13 4.58 2.15 63.00 3.35 1.22 17 0.0800 113.6 114 1.3 2.50 2.07 4.58 2.21 63.40 3.32 1.25 18 0.0840 115.7 116 1.4 2.55 2.04 4.59 2.25 63.60 3.32 1.27 19 0.0890 117.8 118 1.5 2.59 1.99 4.58 2.30 64.00 3.28 1.30 20 0.0940 119.8 120 1.6 2.63 1.96 4.59 2.34 64.20 3.27 1.32 21 0.0990 121.6 122 1.7 2.67 1.92 4.59 2.39 64.50 3.25 1.33 22 0.1040 123.3 123 1.7 2.70 1.89 4.59 2.43 64.70 3.24 1.35 23 0.1500 134.7 135 2.5 2.93 1.64 4.57 2.79 66.40 3.11 1.47 Summit Engineering L Test Read.ings for Specimen No. 2 Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 24 0.2050 144.1 144 3.4 3.11 1.47 4.58 3.12 67.60 3.02 1.55 25 0.2500 149.4 149 4.2 3.20 1.38 4.58 3.31 68.20 2.98 1.60 26 0.3000 154.0 154 5.0 3.27 1.32 4.59 3.46 68.60 2.96 1.63 27 0.3500 157.7 158 5.9 3.31 1.30 4.61 3.56 68.80 2.95 1.66 28 0.4000 161.3 161 6.7 3.36 1.27 4.63 3.65 69.00 2.95 1.68 29 0.4500 164.3 164 7.5 3.39 1.27 4.66 3.68 69.00 2.96 1.70 30 0.5000 167.5 168 8.4 3.43 1.27 4.69 3.70 69.00 2.98 1.71 31 0.5500 169.8 170 9.2 3.44 1.25 4.69 3.75 69.10 2.97 1.72 32 0.6010 172.4 172 10.1 3.46 1.27 4.73 3.73 69.00 3.00 1.73 33 0.6510 175.3 175 10.9 3.49 1.27 4.75 3.75 69.00 3.01 1.74 34 0.7000 177.2 177 11.7 3.49 1.27 4.76 3.76 69.00 3.01 1.75 35 0.7520 179.5 180 12.6 3.50 1.28 4.78 3.73 68.90 3.03 1.75 36 0.8020 181.6 182 13.4 3.51 1.28 4.79 3.74 68.90 3.04 1.75 37 0.8510 183.2 183 14.3 3.51 1.30 4.80 3.71 68.80 3.05 1.75 38 0.9020 184.3 184 15.1 3.49 1.31 4.80 3.67 68.70 3.06 1.75 Summit Engineering Parameters for * No. Specimen Parameter Initial Saturated Consolidated Final Moisture content: Moist soil+tare, gms. 998.800 929.710 Moisture content: Dry soil+tare,gms. 597.320 597.320 Moisture content: Tare,gms. 0.000 0.000 Moisture, % 67.2 71.6 55.6 55.6 Moist specimen weight, gms. 998.80 Diameter, in. 2.867 2.896 2.753 Area, in? 6.456 6.586 5.952 Height, in. 5.998 6.010 5.676 Net decrease in height, in. -0.012 0.334 Net decrease in water volume, cc. 95.000 Wet density, pcf 98.3 98.6 104.8 Dry density, pcf 58.8 57.5 67.4 Void ratio 1.8682 1.9319 1.5025 Saturation, % 97.1 100.0 100.0 Test Readings for Specimen o. 3 Membrane modulus=0.124105 kN/cm2 Membrane thickness=0.02 cm Consolidation cell pressure= 105.50 psi(15.19 ksf) Consolidation back pressure=50.00 psi(7.20 ksf) Consolidation effective confining stress=7.99 ksf Strain rate, %/min. =0.07 Fail.Stress=5.37 ksf at reading no.32 Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 0 0.0000 0.0 0 0.0 0.00 7.99 7.99 1.00 50.00 7.99 0.00 1 0.0030 37.8 38 0.1 0.91 7.39 8.30 1.12 54.20 7.84 0.46 2 0.0090 59.0 59 0.2 1.43 6.97 8.39 1.20 57.10 7.68 0.71 3 0.0150 75.1 75 0.3 1.81 6.60 8.41 1.27 59.70 7.50 0.91 4 0.0200 88.2 88 0.4 2.13 6.29 8.42 1.34 61.80 7.36 1.06 5 0.0250 99.6 100 0.4 2.40 6.02 8.42 1.40 63.70 7.22 1.20 6 0.0280 109.4 109 0.5 2.63 5.77 8.41 1.46 65.40 7.09 1.32 7 0.0350 118.0 118 0.6 2.84 5.56 8.40 1.51 66.90 6.98 1.42 8 0.0400 125.9 126 0.7 3.02 5.36 8.38 1.56 68.30 6.87 1.51 9 0.0450 132.6 133 0.8 3.18 5.18 8.37 1.61 69.50 6.78 1.59 10 0.0500 139.0 139 0.9 3.33 5.01 8.34 1.67 70.70 6.68 1.67 11 0.0550 144.7 145 1.0 3.47 4.87 8.33 1.71 71.70 6.60 1.73 12 0.0600 150.2 150 1.1 3.60 4.72 8.32 1.76 72.70 6.52 1.80 13 0.0650 155.1 155 1.1 3.71 4.58 8.29 1.81 73.70 6.43 1.85 14 0.0700 159.9 160 1.2 3.82 4.45 8.27 1.86 74.60 6.36 1.91 15 0.0750 164.3 164 1.3 3.92 4.33 8.26 1.90 75.40 6.30 1.96 16 0.0800 168.3 168 1.4 4.01 4.23 8.25 1.95 76.10 6.24 2.01 17 0.0850 171.9 172 1.5 4.10 4.13 8.23 1.99 76.80 6.18 2.05 18 0.0900 178.6 179 1.6 4.25 3.95 8.20 2.08 78.10 6.07 2.13 19 0.0980 181.6 182 1.7 4.32 3.86 8.18 2.12 78.70 6.02 2.16 20 0.1080 187.3 187 1.9 4.45 3.72 8.16 2.20 79.70 5.94 2.22 21 0.1520 205.1 205 2.7 4.83 3.15 7.98 2.53 83.60 5.57 2.41 22 0.2050 217.0 217 3.6 5.06 2.75 7.81 2.84 86.40 5.28 2.53 23 0.2550 225.6 226 4.5 5.21 2.49 7.70 3.09 88.20 5.10 2.61 Summit Engineering Test Readings for Specimen No. 3 Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 24 0.3000 231.6 232 5.3 5.31 2.30 7.61 3.30 89.50 4.96 2.65 25 0.3500 236.0 236 6.2 5.36 2.16 7.52 3.48 90.50 4.84 2.68 26 0.4010 239.7 240 7.1 5.39 2.04 7.43 3.64 91.30 4.74 2.69 27 0.4500 242.9 243 7.9 5.41 1.97 7.38 3.74 91.80 4.68 2.71 28 0.5000 244.6 245 8.8 5.40 1.92 7.31 3.82 92.20 4.61 2.70 29 0.5510 247.5 248 9.7 5.41 1.87 7.28 3.89 92.50 4.58 2.70 30 0.6010 249.6 250 10.6 5.40 1.84 7.24 3.93 92.70 4.54 2.70 31 0.6510 251.3 251 11.5 5.38 1.84 7.23 3.92 92.70 4.53 2.69 32 0.7020 253.1 253 12.4 5.37 1.81 7.18 3.96 92.90 4.50 2.68 33 0.7510 255.1 255 13.2 5.36 1.81 7.17 3.95 92.90 4.49 2.68 34 0.S020 257.1 257 14.1 5.34 1.81 7.16 3.94 92.90 4.49 2.67 35 0.8520 257.4 257 15.0 5.29 1.81 7.11 3.92 92.90 4.46 2.65 36 0.9010 259.7 260 15.9 5.29 1.83 7.11 3.89 92.80 4.47 2.64 Summit Engineering Particle Size Distribution Report O O G C C C C C C O O O O O V O V, co 100 I I I I I I I I I I I I I 90 I I ! I I I I I I ( I I I I so I I I l l I I I I I I I I I 70 I I f l 1 1 I I I I I I I I I I I I 1 1 1 1 1 Of I 1 1 1 I I I f l l I w so I I I I I I I I I I I I I I Z 50 I I I I I I I I I I 1 I 1 I U I 11 1 1 I I I I I I I I I W 40 o_ I I I I I I I I I I I I I I ! I I I I I I 30 I ! I I I I I I ! I I I l l 20 I I f I l 1 1 I I I I I I I I I I I I I I I I I I I I I 10 o I I I I I I I 1 I I I I I 100 10 i 0.1 0.01 0.001 GRAIN SIZE-mm. +3„ %Gravel %Sand %Fines Coarse Fine Coarse Medium Fine Silt Clay 0.0 0.0 0.0 0.0 3.5 43.7 1 52.8 SIEVE PERCENT SPEC.* PASS? Material Description SIZE FINER PERCENT (X=NO) Orange-Brown Micaceous Sandy Elastic Silt 0.375 100.0 #4 100.0 #10 100.0 Atterberg_L #20 99.6 mits # 0 96.5 PL= 60 LL= 63 Pl= 3 #60 86.8 Coefficients_ #140 62.1 D90= 0.2870 D85= 0.2325 D60= 0.0982 #200 52.8 D50= D30= D15= D10= CU= Cc= Classification USCS= MH AASHTO= A-5(3) Remarks Moisture Content:66.7% (no specification provided) Location: GT21-19,ST-3 @ 21'-23' Date: 11-17-21 Summit Engineering Client: HDREngineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Ft. Mill South Carolina Project No: 6507.L0006 Figure Tested By: FG Checked By: MH ■■■■1■■■■11■■■ �l■■■■■1■!■■i■■■w■■■■1l�=mil.!■■■■■■■■■■■■■■■■iR ■�.:.a/writ■�■■■�■1■■■■■i■■►1■■!i■1■i■i■■■■■■f■■1�1■■■■i■■■■■■■■■■ • A1f i��lifil��llt�lli������M�� Ii�it�f����RM���■■<Lll���tt■■W11��t� • . iiii■fiiiiiiiiii■fii.� ■i■iiiiii■■ii■iiiii - • . • ■■■■■ilfii■■ii■i■iiii ■■■����ii■��ii�i■iiii - • - •' . • ' ■■■iiiiii■■7■■iiiii.■ � ' �- • • • . ■■■wiiiilii■i■iiiiii■ Ci►Iiliii■■■iiiiiiii■ . • 1 '• •' I.iiiiii■■■iiiiii■■■ ■IAiiliii■■■iiiiii■■■ • • -. • ' :' ■ii■■ii■■iiiiii■■■■ = • ". . 1 1 . 1 li i iiiii■■iiiiii■iii■ iiiii■ii!ri�■iiii■■■■■ - • - • • ' �iiilii■iiilii�■■iit � I �- • • •' ■■;ii■■iiiiii■■ii■■ii • 11 1 11 1 11 1 ►Iii■■iiiiiiiii■■iii iii■■iiiiii■■i■iiii • • -. • •• • .: • ■[■ii■■iiii■�■i■iii■ � . _ : � lii>~��i•iriiiii�iiiii u■iiiiiiii■■■iiiiiii I■■iiiiiiii■■■iiii■ii - - • off 1 11 1 11 ■ii■iii■ii■■iiiii■■ ■iiiiiiii■iiiiiiiii - - • . •1 :1 1 1 All 1 1 1 ■• ' • •1 • • • • • 1 111. o . 15 15 2 12 - i 12 w aCn a- U) 6 0 6 `o m a .> o_ a�i o � 3 o � 3 H 0 0 0% 8% 16°I 0% 8% 16% 15 3 15 4 12 -- i 12 — II / � II g 9 y N w y aU) Y aU) 0 m 6 a� 0 6 o —� `om - co d .> o '> Q H 3 0 3 01 0 D% 8% 15% 0% 8% 16% 6 Peak Strength Total Effective a= 0.54 ksf 0.46 ksf a= 11.2 deg 24.6 deg tan a= 0.20 0.46 4 -- 2- 0 0 2 4 6 8 10 12 p, ksf Stress Paths: Total Effective——— Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Location: GT21-19,ST-3 @ 21'-23' Project No.: 6507.1,0006 Figure SUMMit Engineering Tested By: FG Checked By: MH TRIAXIAL COMPRESSION TEST 11/18/2021 CU with Pore Pressures 10:05 AM Date: 11-17-21 Client: HDR Engineering Project: PLI Concentrator Definitive Feasibility Study Gaston County,North Carolina Project No.: 6507.L0006 Location: GT21-19, ST-3 @ 21'-23' Description: Orange-Brown Micaceous Sandy Elastic Silt Remarks: Type of Sample: Shelby Tube Assumed Specific Gravity=2.70 LL=63 PL=60 PI=3 Test Method: ASTM D 4767 Method B AL MW - Specimen M Specimen Parameter Initial Saturated Consolidated Final Moisture content: Moist soil+tare,gms. 989.190 1005.100 Moisture content: Dry soil+tare,gms. 584.630 584.630 Moisture content: Tare,gms. 0.000 0.000 Moisture, % 69.2 73.4 71.9 71.9 Moist specimen weight, gms. 989.19 Diameter, in. 2.865 2.888 2.875 Area, in.' 6.447 6.550 6.492 Height, in. 5.996 6.013 5.988 Net decrease in height, in. -0.017 0.025 Net decrease in water volume,cc. 8.400 Wet density, pcf 97.5 98.0 98.5 Dry density, pcf 57.6 56.5 57.3 Void ratio 1.9254 1.9807 1.9419 Saturation, % 97.0 100.0 100.0 AlL Test Readings for Specimen No,�-'ff Membrane modulus=0.124105 kN/cm2 Membrane thickness=0.02 cm Consolidation cell pressure=56.90 psi(8.19 ksf) Consolidation back pressure=50.00 psi(7.20 ksf) Consolidation effective confining stress=0.99 ksf Strain rate, %/min.=0.07 Fail. Stress= 1.94 ksf at reading no.26 Summit Engineering Test Readings for Specimen No! I-y Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 0 0.0000 0.0 0 0.0 0.00 0.99 0.99 1.00 50.00 0.99 0.00 1 0.0030 13.1 13 0.1 0.29 0.94 1.23 1.31 50.40 1.08 0.15 2 0.0050 19.8 20 0.1 0.44 0.88 1.32 1.50 50.80 1.10 0.22 3 0.0100 28.4 28 0.2 0.63 0.78 1.41 1.81 51.50 1.09 0.31 4 0.0140 34.7 35 0.2 0.77 0.72 1.49 2.07 51.90 1.10 0.38 5 0.0190 40.0 40 0.3 0.88 0.65 1.53 2.36 52.40 1.09 0.44 6 0.0240 48.6 49 0.4 1.07 0.56 1.64 2.91 53.00 1.10 0.54 7 0.0340 52.1 52 0.6 1.15 0.52 1.67 3.22 53.30 1.09 0.57 8 0.0390 55.3 55 0.7 1.22 0.49 1.71 3.49 53.50 1.10 0.61 9 0.0440 58.1 58 0.7 1.28 0.46 1.74 3.78 53.70 1.10 0.64 10 0.0490 60.6 61 0.8 1.33 0.43 1.77 4.09 53.90 1.10 0.67 11 0.0540 62.7 63 0.9 1.38 0.42 1.80 4.30 54.00 1.11 0.69 12 0.0590 64.9 65 1.0 1.43 0.40 1.83 4.54 54.10 1.12 0.71 13 0.0640 66.8 67 1.1 1.47 0.37 1.84 4.92 54.30 1.11 0.73 14 0.0690 68.4 68 1.2 1.50 0.36 1.86 5.17 54.40 1.11 0.75 15 0.0730 69.5 70 1.2 1.52 0.35 1.87 5.41 54.50 1.11 0.76 16 0.0780 70.9 71 1.3 1.55 0.35 1.90 5.49 54.50 1.12 0.78 17 0.0840 71.9 72 1.4 1.57 0.33 1.90 5.75 54.60 1.12 0.79 18 0.0890 73.2 73 1.5 1.60 0.32 1.92 6.05 54.70 1.12 0.80 19 0.0940 74.1 74 1.6 1.62 0.32 1.93 6.11 54.70 1.13 0.81 20 0.0990 75.1 75 1.7 1.64 0.30 1.94 6.42 54.80 1.12 0.82 21 0.1040 75.8 76 1.7 1.65 0.29 1.94 6.74 54.90 1.11 0.83 22 0.1540 82.4 82 2.6 1.78 0.24 2.03 8.27 55.20 1.14 0.89 23 0.2040 86.3 86 3.4 1.85 0.22 2.07 9.56 55.40 1.14 0.92 24 0.2540 88.6 89 4.2 1.88 0.20 2.08 10.34 55.50 1.14 0.94 25 0.3040 91.1 91 5.1 1.92 0.19 2.11 11.25 55.60 1.15 0.96 26 0.3500 92.9 93 5.8 1.94 0.17 2.11 12.23 55.70 1.14 0.97 27 0.4050 94.3 94 6.8 1.95 0.24 2.20 8.97 55.20 1.22 0.98 28 0.4540 96.0 96 7.6 1.97 0.24 2.21 9.04 55.20 1.23 0.98 29 0.5030 97.3 97 8.4 1.98 0.24 2.22 9.08 55.20 1.23 0.99 30 0.5500 98.4 98 9.2 1.98 0.24 2.23 9.10 55.20 1.24 0.99 31 0.6000 99.1 99 10.0 1.98 0.24 2.22 9.08 55.20 1.23 0.99 32 0.6540 100.7 101 10.9 1.99 0.23 2.22 9.64 55.30 1.23 0.99 33 0.7000 101.5 102 11.7 1.99 0.23 2.22 9.63 55.30 1.22 0.99 34 0.7540 101.9 102 12.6 1.98 0.23 2.21 9.58 55.30 1.22 0.99 35 0.8000 102.1 102 13.4 1.96 0.23 2.19 9.52 55.30 1.21 0.98 36 0.8530 102.3 102 14.2 1.95 0.23 2.18 9.45 55.30 1.20 0.97 37 0.9000 102.8 103 15.0 1.94 0.22 2.15 9.97 55.40 1.18 0.97 Summit Engineering SpecimenParameters for - Specimen Parameter initial Saturated Consolidated Final Moisture content: Moist soil+tare,gms. 1000.420 980.610 Moisture content: Dry soil+tare, gms. 603.710 603.710 Moisture content: Tare, gms. 0.000 0.000 Moisture, % 65.7 70.6 62.4 62.4 Moist specimen weight,gms. 1000.42 Diameter, in. 2.868 2.893 2.815 Area, in 2 6.460 6.573 6.223 Height, in. 6.010 6.034 5.889 Net decrease in height, in. -0.024 0.145 Net decrease in water volume,cc. 49.400 Wet density, pcf 98.2 98.9 101.9 Dry density, pcf 59.2 58.0 62.8 Void ratio 1.8455 1.9066 1.6856 Saturation, % 96.1 100.0 100.0 SpecimenTest Readinq�s for Membrane modulus=0.124105 kN/cm2 Membrane thickness=0.02 cm Consolidation cell pressure=77.80 psi(11.20 ksf) Consolidation back pressure=50.00 psi(7.20 ksf) Consolidation effective confining stress=4.00 ksf Strain rate, %/min.=0.07 Fail.Stress=3.20 ksf at reading no. 32 Def. Deviator Minor Eff. Major Eff, Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P o No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 0 0.0000 0.0 0 0.0 0.00 4.00 4.00 1.00 50.00 4.00 0.00 1 0.0030 18.7 19 0.1 0.43 3.73 4.16 1.12 51.90 3.95 0.22 2 0.0050 25.1 25 0.1 0.58 3.67 4.25 1.16 52.30 3.96 0.29 3 0.0090 39.8 40 0.2 0.92 3.43 4.35 1.27 54.00 3.89 0.46 4 0.0150 51.0 51 0.3 1.18 3.23 4.40 1.36 55.40 3.81 0.59 5 0.0190 59.8 60 0.3 1.38 3.05 4.43 1.45 56.60 3.74 0.69 6 0.0260 67.4 67 0.4 1.55 2.89 4.45 1.54 57.70 3.67 0.78 7 0.0310 74.2 74 0.5 1.71 2.76 4.47 1.62 58.60 3.62 0.85 8 0.0350 79.6 80 0.6 1.83 2.65 4.48 1.69 59.40 3.57 0.92 9 0.0410 84.5 85 0.7 1.94 2.55 4.49 1.76 60.10 3.52 0.97 10 0.0460 88.7 89 0.8 2.04 2.45 4.48 1.83 60.80 3.47 1.02 11 0.0510 92.2 92 0.9 2.12 2.35 4.46 1.90 61.50 3.40 1.06 12 0.0540 95.8 96 0.9 2.20 2.26 4.46 1.97 62.10 3.36 1.10 13 0.0590 99.5 100 1.0 2.28 2.17 4.45 2.05 62.70 3.31 1.14 14 0.0630 102.3 102 1.1 2.34 2.12 4.46 2.11 63.10 3.29 1.17 15 0.0690 105.1 105 1.2 2.40 2.06 4.46 2.17 63.50 3.26 1.20 16 0.0730 107.7 108 1.2 2.46 2.00 4.46 2.23 63.90 3.23 1.23 17 0.0790 110.0 110 1.3 2.51 1.94 4.46 2.29 64.30 3.20 1.26 18 0.0830 111.8 112 1.4 2.55 1.89 4.44 2.35 64.70 3.16 1.28 19 0.0880 113.3 113 1.5 2.58 1.84 4.43 2.40 65.00 3.13 1.29 20 0.0940 115.1 115 1.6 2.62 1.80 4.42 2.46 65.30 3.11 1.31 21 0.1050 118.9 119 1.8 2.70 1.70 4.40 2.59 66.00 3.05 1.35 22 0.1540 129.1 129 2.6 2.91 1.40 4.31 3.08 68.10 2.85 1.45 23 0.2040 135.6 136 3.5 3.03 1.21 4.24 3.50 69.40 2.72 1.51 Summit Engineering Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 24 0.2540 140.8 141 4.3 3.12 1.09 4.21 3.85 70.20 2.65 1.56 25 0.3000 143.8 144 5.1 3.16 1.02 4.18 4.09 70.70 2.60 1.58 26 0.3500 144.8 145 5.9 3.15 0.96 4.12 4.27 71.10 2.54 1.58 27 0.4040 147.2 147 6.9 3.17 0.92 4.09 4.44 71.40 2.51 1.59 28 0.4500 149.9 150 7.6 3.20 0.91 4.11 4.53 71.50 2.51 1.60 29 0.5010 153.4 153 8.5 3.25 0.89 4.14 4.64 71.60 2.52 1.62 30 0.5510 153.7 154 9.4 3.22 0.86 4.09 4.73 71.80 2.48 1.61 31 0.6020 155.3 155 10.2 3.23 0.86 4.09 4.73 71.80 2.48 1.61 32 0.6530 155.4 155 11.1 3.20 0.85 4.05 4.76 71.90 2.45 1.60 33 0.7020 156.0 156 11.9 3.18 0.86 4.04 4.68 71.80 2.45 1.59 34 0.7530 156.2 156 12.8 3.15 0.85 4.00 4.71 71.90 2.43 1.58 35 0.8010 156.3 156 13.6 3.13 0.84 3.96 4.74 72.00 2.40 1.56 36 0.8530 160.4 160 14.5 3.17 0.84 4.01 4.80 72.00 2.42 1.59 37 0.9030 163.3 163 15.3 3.20 0.84 4.03 4.83 72.00 2.43 1.60 Specimen Parameter Initial Saturated Consolidated Final Moisture content: Moist soil+tare, gms. 1021.200 934.860 Moisture content: Dry soil+tare,gms. 609.950 609.950 Moisture content: Tare, gms. 0.000 0.000 Moisture, % 67.4 69.4 53.3 53.3 Moist specimen weight,gms. 1021.20 Diameter, in. 2.868 2.890 2.737 Area, in? 6.460 6.560 5.882 Height, in. 6.032 6.037 5.715 Net decrease in height, in. -0.005 0.322 Net decrease in water volume, cc. 98.200 Wet density, pcf 99.8 99.4 106.0 Dry density, pcf 59.6 58.7 69.1 Void ratio 1.8267 1.8729 1.4382 Saturation, % 99.7 100.0 100.0 Membrane modulus=0.124105 kN/cm' Membrane thickness=0.02 cm Consolidation cell pressure= 105.50 psi(15.19 ksf) Consolidation back pressure=50.00 psi(7.20 ksf) Consolidation effective confining stress=7.99 ksf Strain rate, %/min. =0.07 Fail.Stress=5.39 ksf at reading no.32 Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 0 0.0000 0.0 0 0.0 0.00 7.99 7.99 1.00 50.00 7.99 0.00 1 0.0030 29.9 30 0.1 0.73 7.63 8.36 1.10 52.50 8.00 0.37 2 0.0050 41.4 41 0.1 1.01 7.55 8.56 1.13 53.10 8.05 0.51 3 0.0110 66.0 66 0.2 1.61 7.13 8.74 1.23 56.00 7.93 0.81 4 0.0140 82.8 83 0.2 2.02 6.75 8.78 1.30 58.60 7.76 1.01 5 0.0200 95.9 96 0.3 2.34 6.45 8.79 1.36 60.70 7.62 1.17 Summit Engineering Test Readings forSpecimen • Def. Deviator Minor Eff. Major Eff. Pore Dial Load Load Strain Stress Stress Stress 1:3 Press. P Q No. in. Dial lbs. % ksf ksf ksf Ratio psi ksf ksf 6 0.0240 107.5 108 0.4 2.62 6.19 8.81 1.42 62.50 7.50 1.31 7 0.0280 116.8 117 0.5 2.85 5.96 8.81 1.48 64.10 7.38 1.42 8 0.0340 125.0 125 0.6 3.04 5.76 8.80 1.53 65.50 7.28 1.52 9 0.0400 132.1 132 0.7 3.21 5.56 8.77 1.58 66.90 7.16 1.61 10 0.0430 138.8 139 0.8 3.37 5.39 8.76 1.63 68.10 7.07 1.69 11 0.0490 144.5 145 0.9 3.51 5.24 8.75 1.67 69.10 7.00 1.75 12 0.0520 150.1 150 0.9 3.64 5.10 8.74 1.71 70.10 6.92 1.82 13 0.0580 154.9 155 1.0 3.75 4.94 8.69 1.76 71.20 6.82 1.88 14 0.0620 159.3 159 1.1 3.86 4.81 8.67 1.80 72.10 6.74 1.93 15 0.0670 163.5 164 1.2 3.96 4.69 8.65 1.84 72.90 6.67 1.98 16 0.0720 167.7 168 1.3 4.05 4.58 8.63 1.89 73.70 6.61 2.03 17 0.0770 171.0 171 1.3 4.13 4.48 8.61 1.92 74.40 6.54 2.07 18 0.0820 174.2 174 1.4 4.20 4.39 8.60 1.96 75.00 6.49 2.10 19 0.0870 177.1 177 1.5 4.27 4.31 8.58 1.99 75.60 6.44 2.14 20 0.0920 179.8 180 1.6 4.33 4.22 8.55 2.03 76.20 6.38 2.17 21 0.0970 182.5 183 1.7 4.39 4.13 8.53 2.06 76.80 6.33 2.20 22 0.1020 184.9 185 1.8 4.45 4.06 8.51 2.09 77.30 6.28 2.22 23 0.1540 204.1 204 2.7 4.86 3.44 8.30 2.41 81.60 5.87 2.43 24 0.2040 215.3 215 3.6 5.08 3.07 8.15 2.66 84.20 5.61 2.54 25 0.2540 222.9 223 4.4 5.21 2.81 8.02 2.86 86.00 5.42 2.61 26 0.3000 228.2 228 5.2 5.29 2.64 7.93 3.01 87.20 5.28 2.65 27 0.3540 233.7 234 6.2 5.37 2.49 7.86 3.15 88.20 5.17 2.68 28 0.4000 237.0 237 7.0 5.40 2.40 7.80 3.24 88.80 5.10 2.70 29 0.4500 239.8 240 7.9 5.41 2.33 7.74 3.32 89.30 5.04 2.70 30 0.5030 241.8 242 8.8 5.40 2.28 7.67 3.37 89.70 4.97 2.70 31 0.5540 244.7 245 9.7 5.41 2.23 7.64 3.42 90.00 4.94 2.71 32 0.6000 246.0 246 10.5 5.39 2.20 7.59 3.45 90.20 4.90 2.70 33 0.6530 230.8 231 11.4 5.01 2.22 7.22 3.26 90.10 4.72 2.50 Summit Engineering Appendix B — Operational Details on Waste Rock Pile Construction and Sequencing (DRAFT) Page intentionally left blank. Piedmont Lithium Carolinas,Inc. I Carolina Lithium Operational Details on Waste Rock Pile Construction and Sequencing OPERATIONAL DETAILS ON WASTE ROCK PILE CONSTRUCTION AND SEQUENCING PART 1 - SUMMARY OF CONSTRUCTION SEQUENCING STEPS The following illustrates the proposed construction sequence of the waste rock pile to include sediment and erosion control measure installation, liner installation and waste rock placement (Sheets OOC-1, OOC-2, Sheets CS-1 to CS-7, and Sheets 02CO-GO05 to 02CO-DO05 attached separately). Note, the seven groundwater monitoring wells will be in place prior to land disturbance. This sequence may be revised due to operational requirements as construction progresses across the waste rock pile area: 1.1 SUMMARY OF PREPARATION STEPS 1. Installation of silt fence for waste rock pile land disturbance (Sheet CS-1, see 2.1) 2. Construction of erosion and sediment control structures (Sheet CS-1, see 2.1). 3. Construction of haulage and internal access roads (Sheet CS-1, see 2.1). 4. Clearing and grubbing for the waste rock pile and soil excavation areas (Sheets CS-1 to CS-3, see 2.2). Waste rock pile footprint will be cleared and grubbed in eight stages of approximately 15-acres each. 5. Prepare subgrade in the waste rock pile area for clay liner placement(Sheets CS-1 to CS- 3, see 2.3). Subgrade will be prepared in the waste rock pile footprint in eight stages of approximately 15-acres each. 6. Excavation from planned mine pit areas or other disturbed areas shown in the Mine Permit Application for clay liner material (see 2.3). 7. Repeat Steps 4-5 for Liner Stages 1-8 (Sheets CS-1 to CS-3). 1.2 SUMMARY OF LINER CONSTRUCTION STEPS 8. Haulage of clay liner material to waste rock pile area for placement (see 3.1). 9. Begin clay liner test strip construction on northeastern corner of waste rock pile footprint (Sheet CS-1, see 3.1). 10. Once the clay liner test strip has been tested and meets the clay liner requirements, clay liner will be placed in four, 6-inch compacted lifts in each liner stage (Sheets CS-1 to CS- 3, see 3.1). 11. Once clay liner has passed the required testing and thickness checks, excavation and haulage of protective material to waste rock pile for placement will commence(Sheets CS- 1 to CS-4, see 3.2). 12. Construct protective layer over clay liner in 1-foot-thick lifts for a minimum 2-feet layer thickness while expanding the clay liner system to the next stage of development (Sheets CS-1 to CS-4, see 3.2). 13. Repeat Steps 9-12 for Liner Stages 1-8 until construction of the clay liner and protective layer is complete for the Phase 1 waste rock pile footprint(Sheets CS-1 to CS-4). 1.3 SUMMARY OF WASTE ROCK PILE CONSTRUCTION STEPS 14. Complete construction of the conveyor system from South Pit to waste rock pile, including connection with conveyor from concentrator plant for tailings (Sheets CS-3 and CS-4, see 3.3). 1 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Summary of Construction Sequencing Steps 15. Once mining commences in South Pit, convey crushed rock and concentrator plant tailings to waste rock pile area for placement(Sheets CS-5 to CS-7, see 3.3). 16. Use mining class dozer to push waste rock and create waste rock pile using maximum loose lift placement thickness of 6 feet and 20-ft vertical lifts (see 3.4). 1.4 SUMMARY OF TIMEFRAME The liner will be installed over eight stages and each stage is approximately 15 acres. Once all eight liner stages are completed,the waste rock pile Phase 1 construction will commence.Towards the end of Phase 1 waste rock pile construction, the liner preparation and placement in the Phase 2 area will commence (Table 1). Phase 2 of waste rock pile construction will commence once the liner is in place in the Phase 2 area. Liner Timeframe (Stages 1-8) The assumptions associated with each 15-acre stage include the following approximate timeframes for a total of 11 weeks (2.75 months) per 15-acre stage: • 3 weeks for subgrade preparation (clearing, grubbing, rolling, etc.) • 6 weeks for liner placement installment(material placement, compaction, testing) • 2 weeks for protective layer installment For eight liner stages, it is anticipated to take approximately 22 months to install the clay liner underneath the Phase 1 waste rock pile footprint. For each liner stage, the protective layer will be installed immediately after the clay liner placement has met the design requirements such that portions of the clay liner will have minimal exposure during the 2-week protective layer placement. The clay will be maintained in accordance with 3.1 below. Waste Rock Timeframe (Phases 1 and 2) For waste rock placement, the approximate construction timeframes are based on vertical construction of the pile shown in Table 1. Phase 1 is anticipated to take approximately 19 months and Phase 2 is approximated to take three months for a total of 22 months of construction for the waste rock pile (Phases 1 and 2). Table 1. Estimated Construction Timeframe for Liner Installation and Waste Rock Placement. Sequence Sheet Elevations Approximate Construction Cumulative feet Timeframe (months) (months) Liner- Stage 1 CS-1 TBD 2.75 2.75 Liner- Stage 2 CS-2 TBD 2.75 5.5 Liner- Stage 3 CS-2 TBD 2.75 8.25 Liner- Stage 4 CS-2 TBD 2.75 11 Liner- Stage 5 CS-2 TBD 2.75 13.75 Liner- Stage 6 CS-3 TBD 2.75 16.5 Liner- Stage 7 CS-3 TBD 2.75 19.25 Liner- Stage 8 CS-3 to CS-4 TBD 2.75 22 WR- Phase 1 CS-5 840 to 880 2.4 24.4 WR- Phase 1 CS-5 880 to 920 9.3 33.7 WR- Phase 1 CS-5 920 to 960 4.4 38.1 WR- Phase 1 CS-5 960 to 1000* 2.3 40.4 WR- Phase 1 CS-6 1000 to 1040 0.7 41.4 WR- Phase 1 CS-6 1040 to 1068 0.1 41.2 2 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Preparation Sequencing Details Sequence Sheet Elevations Approximate Construction Cumulative feet Timeframe months months WR- Phase 2 CS-7 1068 to 1090 2.7 43.9 The clearing and grubbing of the Phase 2 area begins when Phase 1 Waste Rock Pile is at the approximate 960-foot elevation.After which the subgrade will be prepared,clay liner,and protective layer placed prior to Phase 2 waste rock placement(approximate 1068-foot elevation). PART 2 - PREPARATION SEQUENCING DETAILS 2.1 CONSTRUCTION OF EROSION AND SEDIMENT CONTROL STRUCTURES a. Associated with Waste Rock Pile land disturbance. b. Subsurface utilities (power lines,water lines, old wells, gas lines, etc.)will be identified and either removed or clearly marked prior to any disturbance. c. Silt fence will be installed per the Mine Permit Application before any disturbance is permitted. d. Prior to clearing and grubbing of the area associated with the waste rock pile,the designed sediment basins and diversion ditches will be constructed per design in the Mine Permit Application and reviewed by the NCDEQ Mooresville Regional Office. All surface water runoff will be directed to one of ten sediment basins designed for erosion and sediment control of the waste rock pile acreage. Sediment Basins (SB) SB-1 through SB-10 will be lined with a synthetic liner with geosynthetic clay liner (GCL) subgrade as shown on the Sediment Basin Detail Sheets(Sheets 02CO-GO05 to 02CO-D005).The synthetic liner will be installed to the basin crest elevation with a three-foot runout to the anchor trench. Batten strips will be utilized to adhere the synthetic liner to concrete structures and a pipe boot will be installed for principal spillway culverts. A cushion geotextile will be installed above the synthetic liner in locations where rip rap will be placed. e. Equipment utilized in this process includes bulldozers, skid steers, mulchers, excavators, and trucks to haul cleared vegetation and root systems. f. Upon installation of the drainage control structures, clearing and grubbing of the waste rock pile area may begin. 2.2 CLEARING AND GRUBBING OF THE WASTE ROCK PILE AREA a. The Contractor shall clear and grub surface objects, trees, stumps, roots, grass, and deleterious materials designated to be removed. (i) This includes objectionable material, rubbish,junk, brush roots, down timber, rotten wood and disposing of vegetation and debris at least 20 feet beyond the waste rock site footprint for access and inspection and/or as directed by the Owner. (ii) Material removed during the clearing and grubbing operations shall be disposed of by the Contractor at an approved disposal area in a manner satisfactory to the Owner. Disposal of excess or unsuitable material must conform to requirements of appropriate regulatory agencies and Contractor shall obtain appropriate permits for disposal. Topsoil and select cover soil materials shall be stockpiled for future use as final cover for the completed waste rock site. (iii) The Contractor shall note that timber within the project construction limits to be cleared is his property except that claimed and removed by the Owner, and shall be disposed of under his own arrangements.All such timber shall be removed from the project construction limits well in advance of grading operations. a. The Contractor shall not commence subgrade preparation operations in any of the liner stages (15-acre increment) until the clearing and grubbing operations within the affected liner stage have been completed. Care shall be taken to minimize sediment laden runoff. 3 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Preparation Sequencing Details b. The entire subgrade within the limits of the waste rock site shall be proof rolled with heavy pneumatic-tired equipment to delineate soft intervals near the ground surface. Existing soft, unsuitable soil materials within the footprint of the proposed waste rock site shall be excavated to competent soil or rock. Excavated unsuitable material shall be stockpiled for future use or disposed of onsite. If necessary, loose natural soils may be over-excavated and replaced with acceptable soil material that is free of organics. The excavation, removal and replacement of unsuitable materials shall be performed in the presence of the Certifying Engineer or authorized representative. c. The Contractor shall backfill stump holes, holes from other obstructions and depressions resulting from the clearing and grubbing operations with suitable material and shall compact the backfill material. d. Burying debris on site is prohibited. e. Materials removed during clearing and grubbing operations shall be disposed of in compliance with local and state ordinances or regulations.. f. Equipment utilized in this process includes bulldozers, skid steers, mulchers, excavators, and trucks to haul cleared vegetation and root systems (Figure 1). *?s` + S { Figure 1. Example Of Site Being Cleared and Grubbed. 2.3 PREPARATION OF GROUND SURFACE FOR COMPACTED CLAY LINER a. Initial Site Development—construction of internal roadways and associated infrastructure for hauling route between excavation area for clay liner and protective layer materials and the rock pile area. b. Clay liner materials and protective layer materials shall be excavated from planned mine pit areas or other disturbed areas shown in the Mine Permit Application. c. Silt fence will be installed per the Mine Permit Application before any disturbance is permitted in the initial internal roadway construction areas and in excavation areas for clay and protective layer materials. 4 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Construction Details d. Prior to clearing and grubbing associated with the initial roadway construction areas and excavation areas for clay and protective layer materials, the designed erosion and sediment control structures will be constructed per design in the Mine Permit Application and reviewed by the NCDEQ Mooresville Regional Office. Surface water runoff will be directed to the erosion and sediment control structures of the initial internal roadway construction areas and excavation areas for clay and protective layer materials. e. Internal roadways,overpasses,and crossings for the route between the clay and protective layer material excavation areas and the waste rock pile will be constructed to allow for clay liner material and protective layer material to be delivered to the waste rock pile site per the Mine Permit Application. f. Equipment utilized in this process includes bulldozers, skid steers, mulchers, excavators, and trucks to haul clay material and protective layer material to the waste rock pile area. g. Contractor shall proof roll the subgrade with a pneumatic tired vehicle of at least 20 tons, making passes across the area under the observation of quality control and assurance personnel. The subgrade shall be smooth and free of vegetation, sticks, roots, foreign objects, and debris. The clay liner shall not be placed over areas deemed unacceptable. PART 3 - CONSTRUCTION DETAILS 3.1 INSTALLATION OF COMPACTED CLAY LINER a. Clay liner material must be approved for use by the design/permitting engineer. b. Clay liner material may be naturally occurring material from either onsite or offsite. Soil material may be amended with bentonite to achieve the desired hydraulic conductivity(1 x 10-' [1 E-7] cm/sec). c. An offsite material source characterization shall be conducted to determine the quality and quantity of material for use as clay liner should offsite material be needed. d. In the case of bentonite soil amendment, the soil source shall have a design mix analysis conducted on the coarsest soil samples to determine the minimum bentonite content required to consistently meet the required in-place hydraulic conductivity. e. Clay liner material shall be transported to the prepared waste rock pile subgrade from the engineer-approved clay excavation area. f. Contractor will conduct a clay liner test strip 100 feet long by 50 feet wide by 2 feet thick. (i) The test pad will be placed in four, six-inch thick compacted lifts using equipment that will place the remainder of the clay layer. Prior to placement of successive lifts, the surface of the lift in place shall be scarified to eliminate lift interfaces. (ii) The test strip will determine the placement requirements (Le., equipment type, number of equipment passes and soil moisture content)to implement for the entire clay layer placement. If the test strip fails to achieve the desired results, the soil material of the strip shall be completely removed, and additional test strip(s) shall be constructed until the requirements are met. (iii) The clay hydraulic conductivity must equal or be slower than 1.0 x 10-7 cm/sec. g. Clay liner shall be placed on a subgrade that has been proof rolled and that is smooth and free of vegetation, sticks, roots, foreign objects, and debris. h. The soil liner shall be installed in six-inch compacted lifts. The material shall be placed consistent with criteria developed from construction of a satisfactory test strip. i. Equipment shall be used such that bonding of the lifts will occur. Equipment shall have cleats or other protrusions of such length necessary to completely penetrate the loose lift. Compaction shall be performed using an appropriately heavy, properly ballasted, 5 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Construction Details penetrating foot compactor making a minimum number of passes as approved by the quality control and assurance personnel based on the soil liner test strip. (i) Contractor shall key in edges of the clay liner system such that there is no vertical seam through the 2-foot clay liner. (ii) Contractor shall key in compacted clay lifts to one another. j. During construction, exposed finished lifts of the soil liner material should be sprinkled with water to minimize desiccation, as necessary. k. If desiccation and crusting of the lift surface occurs prior to placement of the next lift, this area shall be scarified to a minimum depth of two inches or until sufficiently moist materials are encountered,whichever is greater.After scarification,the superficial material should be reworked to obtain a moisture content at least 2 percent above optimum moisture content (to be determined based on material source characterization study and soil test strips). Alternatively, the drier superficial soil may be stripped and mixed with additional moist soil to achieve a moisture content satisfying the project requirements. I. No frozen material shall be placed, and no material shall be placed on frozen material. Frozen in-place material shall be removed prior to placement of additional soil material. m. Material which has been subjected to a freeze/thaw cycle(s) shall be disked and recompacted prior to placement of subsequent lifts. n. At the end of each day's construction activities,completed lifts or sections of the compacted soil liner should be sealed by rolling with a smooth drum roller. o. Clay liner field density must be conducted on a frequency of 1 test per 10,000 square feet per lift of material and equal or exceed 95% compaction. p. Clay liner hydraulic conductivity testing must be performed for every acre per lift. q. Holes in the compacted soil liner created as a result of destructive testing (e.g., thin-walled Shelby tube sampling and nuclear gauge, field density determinations) shall be backfilled and tamped by rod uniformly in 2-inch-thick lifts. The backfill material shall be the same liner construction material or hydrated bentonite powder. r. Clay liner shall be surveyed on a 100-foot grid to confirm the minimum 2-feet thickness has been met. s. Each phase of the clay liner shall be maintained in a moist condition to prevent drying and cracking while awaiting test results and approval by the engineer to cover with protective layer material. 3.2 INSTALLATION OF PROTECTIVE LAYER a. Overburden excavated during mine pit stripping operations shall be utilized to construct the protective layer above the clay liner. Overburden material shall be free from topsoil, organic matter, debris, cinders, saturated material, and frozen material. b. Protective layer material shall be placed and compacted in 1-foot lifts for a minimum of 2 feet lift thickness. c. Protective layer material shall only be placed on the compacted clay liner after testing of the liner materials and thickness have been approved by the engineer. d. Contractor shall achieve 90%compaction per lift of protective layer material by compactor, proof rolling, or dozer tracking. Compaction shall be confirmed with field density testing. e. Equipment utilized in this process includes bulldozers, skid steers, excavators, compactors, and trucks to haul clay material and protective layer material to the rock pile area. 3.3 PLACEMENT OF WASTE ROCK a. Waste rock from mine pit excavation shall be transported via a conveyor system to the waste rock pile area. Concentrator Plant tailings shall be intermingled with the waste rock 6 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Reclamation of Waste Rock Pile (mixed at transfer points on the conveyor belt) and transported via the same conveyor system to the Waste Rock Pile. Material disposed of in the waste rock site shall consist predominantly of coarse waste rock produced from the mine site, with a small portion of the material consisting of fine tailings generated from the concentrator plant. The coarse waste rock,which is approximately 93-95%of the material to be placed in the above ground pile, is crushed through a primary crusher nominal 14-inch size. The finer material, the concentrator plant tailings (minus 1 mm material), makes up the remaining approximately 5-7% of material to be placed in the pile. b. A mining-class bulldozer will be used to push the waste rock from the conveyor discharge point and spread the waste rock into lifts. The maximum loose lift thickness shall not exceed six (6)feet. Each lift will be compacted by multiple bulldozer passes. 3.4 PROGRESSION OF WASTE ROCK PILE a. Waste rock will be placed in horizontal lifts in 20-foot elevation intervals with 2:1 outslopes until final design elevation is achieved. Safety benches will be installed with the completion of each 20-foot elevation interval for stability and to assist with stormwater runoff control. b. The surfaces of the waste rock site shall be graded to drain to the appropriate sediment basin via a system of ditches and flumes as per the Mine Permit Application. PART 4 - RECLAMATION OF WASTE ROCK PILE a. Reclamation of the waste rock pile occurs as the construction of the pile commences. b. At the completion of each 20-foot elevation interval, the final outslopes of each interval shall be covered with a minimum of twelve inches of soil and seeded. Soil material shall be consistent with a low permeability natural soil cover or other materials capable of supporting vegetation. c. Re-vegetation of final waste rock pile slopes includes placing a low permeability natural soil cover or other materials capable of supporting vegetation on the surface of all final waste rock slopes and subsequently planting to establish a continuous stand of vegetation. d. All earth moving equipment used to place cover soil shall be sized to limit impacts due to over-compaction of soil that may hinder vegetation growth. e. Soil cover and vegetation in accordance with the North Carolina Department of Energy, Mineral and Land Resources regulations are presented in Attachment A. f. The dome-like nature of the final reclaimed surface will minimize infiltration and minimize the potential for flat or depressed areas to form and collect pools of water. 7 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Reclamation of Waste Rock Pile Page intentionally left blank. 8 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Attachment A—Revegetation Plan ATTACHMENT A- REVEGETATION PLAN Piedmont Lithium Carolinas,Inc. I Carolina Lithium Attachment A—Revegetation Plan Page intentionally left blank. APPLICATION FOR A MINING PERMIT 7. Describe your plan for revegetation or other surface treatment of the affected areas. This plan must include recommendations for year-round seeding, including the time of seeding and the amount and type of seed, fertilizer, lime and mulch per acre. The recommendations must include general seeding instructions for both permanent and temporary revegetation. Revegetation utilizing only tree plantings is not acceptable. Recommendations can be sought from: a. Authorized representatives of the local Soil and Water Conservation District; b. Authorized representatives of the NC Forest Service,Department of Agriculture and Consumer Services; c. Authorized county representatives of the North Carolina Cooperative Extension Service, specialists and research faculty with the Colleges of Agriculture and Life Sciences and Forest Resources at North Carolina State University; d. North Carolina licensed landscape architects; e. Private consulting foresters referred by the NC Forest Service, Department of Agriculture and Consumer Services; f. N.C. Erosion and Sedimentation Control Planning and Design Manual; g. N.C. Surface Mining Manual: A Guide for Permitting, Operation and Reclamation; h. Others as may be approved by the Department. LIME -RATE OF APPLICATION(tons/acre): Base application rate on soils test to be conducted by future contractor;however,in lieu of soils test apply 2,000-3,000 lbs/acre on coarse-textured soils and 4,000-6,000 tons/acre on fine-textured soils.Rate of application recommended by the NCDEQ NC Erosion and Sediment Control Planning and Design Manual—Chapter 6. FERTILIZER-ANALYSIS AND RATE OF APPLICATION (pounds/acre): Base application rate on soils test to be conducted by future contractor;however,in lieu of soils test apply a 10-10-10 grade fertilizer at 700-1,000 lb/acre,or substitute of similar fertilizer grade and ratio.Rate of application recommended by the NCDEQ NC Erosion and Sediment Control Planning and Design Manual—Chapter 6. SEED - TYPE(S) AND RATE(S) OF APPLICATION INCLUDING YEAR-ROUND SEEDING SCHEDULE (pounds/acre): [NOTE: Include Legumes] Seed Types: Seeding Dates: Seeding Rates: Permanent Seed NC Steep Slope Mix[ERNMX-310] Throughout 45 lbs/acre Native Habitat for Strip Mines Mix[ERNMX-I I I] Throughout 20 lbs/acre Native Steep Slope Mix with Annual Ryegrass [ERNMX-181] February 15-August 15 60 lbs/acre Native Steep Slope Mix with Grain Rye [ERNMX-181-2] August 15-February 15 75 lbs/acre Temporary Cover Seed Browntop millet February 15-August 15 10 lbs/acre Annual rye grain August 15-February 15 30 lbs/acre o NC Steep Slope Mix [ERNMX-310] is a steep slope mix for the Piedmont and Coastal Plain regions of NC. This pollinator- friendly mix provides food and cover for wildlife. This seed mix can be purchased from ERNST Seeds. o Native Habitat for Strip Mines Mix[ERNMX-1111 is an erosion control and revegetation mix. It's a permanent meadow mix for wildlife cover and pollinator habitat on disturbed sites.This seed mix can be purchased from ERNST Seeds. o Native Steep Slope Mix with Grain Rye [ERNMX-18 11 is a steep slope mix. The native grass and forb species tolerate poor soils typically found on steep slopes in the eastern United States. Includes ticktrefoils (Desmodium spp.) and partridge peas (Chamaecrista spp.),both of which are leguminous species. This seed mix can be purchased from ERNST Seeds. - 1 - APPLICATION FOR A MINING PERMIT o Native Steep Slope Mix with Grain Rye [ERNMX-181-21 is a steep slope mix. Use this seed mix with grain rye as a cover crop. Includes ticktrefoils (Desmodium spp.)and partridge peas(Chamaecrista spp.),both of which are leguminous species. This seed mix can be purchased from ERNST Seeds. MULCH-TYPE AND RATE OF APPLICATION(pounds/acre)AND METHOD OF ANCHORING: Application rates of wheat straw shall be 4,000 lbs/acre.On less than 3:1 slopes,tack is not required. On slopes 3:1 or greater,tack anchoring is required. Rate of application recommended by the NCDEQ NC Erosion and Sediment Control Planning and Design Manual—Chapter 6. OTHER VEGETATIVE COVERS — TYPE (S) AND RATE (S) OF APPLICATION INCLUDING SEEDING SCHEDULE (pounds/acre, trees/acre, spacing of trees/shrubs, etc): During reclamation, a native pollinator mix can be utilized from ERNST Seeds utilizing the recommended rate for that particular seed mix. Revegetation and/or reforestation plan approved by: Signature 1�:;I -0 Date 12-08-21 Print Name DAVID H. WEST Title SR. LANDSCAPE ARCHITECT; RLA NORTH CAROLINA #2076 Agency HDR, INC. -2- Appendix C — Waste Rock Pile Monitoring and Treatment Plan (DRAFT) Page intentionally left blank. Waste Rock Pile Monitoring and Treatment Date: Wednesday, September 06, 2023 Project: Carolina Lithium To: Monique Parker From: HDR and MMA Subject: Proposal for Monitoring and Treatment of Waste Rock Leachate/Runoff(Surface Discharge and Potential Groundwater Interaction) The North Carolina Department of Environmental Quality(NCDEQ)— Division of Energy, Mineral, and Land Resources (DEMLR) issued an Additional Information (ADI) #3 request on May 30, 2023. In ADI #3, DEMLR stated the requirement of a liner to be placed under the waste rock pile to protect water quality. To compliment the requirement for a liner under the waste rock pile, the following proposal and plan for monitoring and potential mitigation of the discharge from the waste rock pile is presented. The selection of parameters for monitoring is based on extensive test work that has been conducted on representative samples of waste rock material. The reports detailing these test results are referenced below. Details of the test procedures and results are included in these reports. • Leaching Environmental Assessment Framework (LEAF) and Accelerated Weathering of Solid Materials Using a Modified Humidity Cell (ASTM D 5744-96)Collaboration Technical Summary (dated April 2023); prepared by Marshall Miller &Associates The results of the humidity cell and LEAF test work described in the above-referenced reports form the basis for selection of parameters for monitoring surface water discharged from the waste rock pile. The test results also provide the basis for a groundwater monitoring plan for wells surrounding the waste rock pile. Suggested Surface Water Monitoring There are 10 proposed sediment basins surrounding the waste rock pile. These basins will receive runoff and contact stormwater from the waste rock pile during construction and stormwater runoff once construction and reclamation are completed. The proposed monitoring parameters and potential treatment described below are specific to these 10 basins. Based on monitoring parameters commonly required in mining applications, parameters listed in the NCG02 General Permit for Lithium Ore Mining, and the results of the humidity cell and LEAF tests, the recommended parameters for monitoring of surface water (Basins 1-10) are provided below in Table 1. A rainfall gauge will be placed in the vicinity of the waste rock pile to record rainfall amount (in inches) to satisfy NPDES requirements. 1 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Waste Rock Pile Monitoring and Treatment Continuous monitoring of pH and flow rate is proposed at the inflow and outflow of the basins (Sheet CS-3). Bi-weekly grab sampling is proposed for laboratory analyses listed in Table 1, depending on precipitation events (measurable flow). Typical laboratory turnaround time for analysis and reporting is two+ weeks from receipt of samples by the laboratory; thus, more frequent sampling is not recommended. Piedmont Lithium proposes to begin collecting background surface water quality data from streams in the vicinity of the waste rock pile up to one year prior to commencement of mine operations. These data will be used to evaluate naturally occurring concentrations of inorganic constituents (e.g. arsenic) as a baseline for developing statistically-derived site-specific background threshold values (BTVs). Statistically derived BTVs will be compared to established criteria (Surface Water Quality Standards in 15A NCAC 02B [213 Standards]) to identify site- specific target levels (SSTLs) for each monitored constituent identified in Table 1. Compliance sampling results would then be compared to those SSTLs to evaluate compliance and the potential need for treatment. Once the pile is built out (construction is complete), is seeded and vegetated, the applicant reserves the right to re-evaluate the monitored parameters and frequency of monitoring, taking into consideration the results of the monitoring program during construction. 2 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Waste Rock Pile Monitoring and Treatment Table 1. Proposed moni oring parameters and fre ency of samplingfor surface water Basins 1-10 . Frequency2 Field or Parameter' Every 2 Lab Method Reasoning Weeks Parameter 3 YSI Water Common for mining applications; indicator for potential solubility of pH x Field Quality Meter(or metals similar Flow rate3 x Field Weir(or similar) Common for mining applications; representative nature of sampling feasibility YSI Water Common for mining applications; listed in NCG02 for lithium ore Turbidity x Field Quality Meter(or similar) mines YSI Water Specific Conductance x Field Quality Meter(or Common for water quality sampling events similar YSI Water Temperature x Field Quality Meter(or Common for water quality sampling events similar YSI Water Dissolved Oxygen x Field Quality Meter(or Common for water quality sampling events similar Total Aluminum x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests; common for mining applications; listed in NCG02 for lithium ore mines Total Manganese x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Nickel x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Cadmium x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Cobalt x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Lead x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Arsenic x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Chromium x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests 3 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Waste Rock Pile Monitoring and Treatment Frequency' Field or Parameter' Every 2 Lab Method Reasoning Weeks Parameter Total Iron x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Zinc x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Vanadium x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Lithium x Lab EPA 200.8 Based on results from LEAF and/or humidity cell tests Total Fluoride x Lab EPA 300.0 Listed in NCG02 for lithium ore mines TSS x Lab SM 2540D Common for mining applications; listed in NCG02 for lithium ore mines Settleable Solids x Lab SM 2540F Common for mining applications; listed in NCG02 for lithium ore mines Total Dissolved Solids x Lab SM 2450C Common for mining applications Nitrate/Nitrite N x Lab EPA 353.2 Common for mining applications; indicator of blasting agents Ammonia N x Lab EPA 350.1 Common for mining applications; indicator of blasting agents Total Organic Carbon x Lab SM 5310 Indicator of Total Petroleum Hydrocarbons(TPH) (TOC) Parameters should be analyzed utilizing laboratory methods with detection limits less than regulatory standards. 2 As the contact stormwater would be precipitation-induced,there may be times in which there is no discharge(or measurable flow);therefore, if there is no discharge or resulting flow, grab sampling would not be conducted. 3 Note:continuous monitoring of pH and flow rate is also proposed at the inflow and outflow of the basins. 4 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Waste Rock Pile Monitoring and Treatment Suggested Surface Water Treatment As noted in Table 1, a comprehensive monitoring program is suggested; however, those parameters of potential concern per the humidity cells and LEAF test work results are those for which mitigation treatment is proposed if influent SSTLs are exceeded (Table 2). As there are 10 sediment basins proposed to capture Waste Rock Pile contact stormwater, only those basins that have exceedances of the SSTL would be treated. Table 2. Proposed surface water treatment for parameters of concern Parameter Treatment pH Temporary feed of sulfuric acid added to bring pH back to range of 6.5-8.5. This will require pacing of acid feed to influent flow. Aluminum If pH conditions are higher than 8.5, decrease the pH to allow the reprecipitated solids to settle in the sediment basins. Target pH should be 6.5. Pump from the basin inlet(receiving water from the pile)to a deployable(as needed)mixed frac tank,where chemical addition would take place. Arsenic Addition of ferric chloride and pH adjustment to 6.5. Note that ferric chloride is acidic, so addition of an alkali (sodium hydroxide)may be required instead of acid addition. Following this, a polymer would be added for flocculation and the discharge from the frac tank would then flow back by gravity to the sediment basin for solids settling. The solids would be allowed to settle in the sediment basins prior to discharge. If pH conditions are higher than 8.5, decrease the pH to allow the reprecipitated solids to settle in the sediment basins. Target pH should be 6.5. Vanadium It is anticipated that vanadium would coprecipitate with aluminum; however, if vanadium requires removal in the absence of aluminum removal, then addition of ferric chloride in a deployable frac tank for chemical addition (similar to Arsenic treatment above)would be necessary. The most effective removal mechanism is biological treatment. In this case,for removal of a few mg/L, feeding a carbon source to the sediment basin in question would provide an anoxic Nitrate/Nitrite N environment where denitrifying bacteria could be effective. If the source is determined to be related to blasting activities, additional mitigation may be implemented via mining engineering/blasting plan modifications. Total Organic Addition of a feed of hydrogen peroxide or activated carbon to the sediment basin of concern. Carbon (TOC) Other options exist and can be jar tested prior to use. If other metals that are monitored are outside their acceptable range,jar testing will be done to identify if coprecipitation with ferric chloride will be effective, or if a small dose of an Other metals organosulfide polymer is more effective(or both). The same configuration would be used as treatment for arsenic and standalone vanadium, with chemical addition at a deployable external tank and gravity return to the sediment basin. 5 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Waste Rock Pile Monitoring and Treatment Suggested Groundwater Monitoring Seven groundwater monitoring well locations are proposed around the waste rock pile to monitor the quality of water in the water table aquifer. Three monitoring locations will be established with co-located water table and bedrock monitoring wells, as these locations will also be used to monitor water level. Each well will be installed within 250 feet of the waste rock pile extent and will be placed strategically in areas located between the waste rock pile and surface water features, where applicable. Based on the monitoring parameters listed for surface water (Table 1), similar parameters are proposed for monitoring of groundwater (Table 3). Piedmont Lithium proposes weekly monitoring of pH and water levels in the monitoring wells, and monthly sampling and analysis for the parameters listed in Table 3. Similar to surface water, Piedmont Lithium proposes to install and sample groundwater monitoring wells around the waste rock pile prior to mine operation to obtain groundwater quality data representative of seasonal fluctuations in groundwater geochemistry. These data will be used to evaluate naturally occurring concentrations of inorganic constituents (e.g., arsenic) as a baseline for developing statistically derived site-specific BTVs for groundwater. Statistically derived BTVs will be compared to established criteria (Ground Water Quality Standards in 15A NCAC 02L [2L Standards]) to identify SSTLs for each monitored constituent identified in Table 3. Compliance sampling results would then be compared to those SSTLs to evaluate compliance. 6 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Waste Rock Pile Monitoring and Treatment Table 3. Proposed monitoring parameters and frequency of sampling for groundwater. Frequency Field or Parameter' Lab Method Reasoning 1x/Month Parameter pH2 x Field YSI Water Quality Common for mining applications; indicator for potential solubility of metals Meter(or similar) Water leve12 x Field Heron Dipper-T2 Common for mining applications; representative nature of sampling feasibility (or similar) Turbidity x Field YSI Water Quality Common for mining applications; listed in NCG02 for lithium ore mines Meter(or similar) Specific Conductance x Field YSI Water Quality Common for water quality sampling events Meter(or similar) Temperature x Field YSI Water Quality Common for water quality sampling events Meter(or similar) Dissolved Oxygen x Field YSI Water Quality Common for water quality sampling events Meter(or similar) Total Aluminum x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests; common for mining applications; listed in NCG02 for lithium ore mines Total Manganese x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Nickel x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Cadmium x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Cobalt x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Lead x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Arsenic x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Chromium x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Iron x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Zinc x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests 7 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Waste Rock Pile Monitoring and Treatment Frequency Field or Parameter' Lab Method Reasoning 1x/Month Parameter Total Vanadium x Lab EPA 200.7 Based on results from LEAF and/or humidity cell tests Total Lithium x Lab EPA 200.8 Based on results from LEAF and/or humidity cell tests Total Fluoride x Lab EPA 300.0 Listed in NCG02 for lithium ore mines Nitrate/Nitrite N x Lab EPA 353.2 Common for mining applications; indicator of blasting agents Ammonia N x Lab EPA 350.1 Common for mining applications; indicator of blasting agents Total Organic Carbon x Lab SM 5310 Indicator of Total Petroleum Hydrocarbons(TPH) (TOC) Parameters should be analyzed utilizing laboratory methods with detection limits less than regulatory standards. 2 Note:Weekly monitoring of pH and water levels is also proposed in the monitoring wells. In the presence of a liner under the waste rock pile, it is not anticipated that groundwater would be affected by waste rock pile runoff/l each ate. Monitoring of the groundwater is to provide validation that the liner is effective. Therefore, mitigation/treatment is not anticipated. 8 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Waste Rock Pile Monitoring and Treatment Other Considerations In DEMLR's ADI #3 request, additional details about certain monitoring parameters were requested (question #2). The applicant believes that Table 1 (surface water) and Table 3 (groundwater wells) provide a comprehensive list of monitoring parameters that includes many of the mentioned parameters in ADI #3, question #2. Please find additional clarity related to specific parameters: • Radiological Elements— Naturally-occurring radioactive materials were considered during the substantial humidity cells and LEAF test work programs. Uranium was detected at very low levels. North Carolina does not have surface or groundwater standards for either element, and the USEPA has a Maximum Contaminant Level (MCL) for public drinking water for uranium, which is 30 ug/L. In all the testwork conducted to date,the peak uranium concentration was 12.2 mg/L for one occurrence, with remaining results ranging from 0.009 to 7.46 mg/L. The USEPA does not have an MCL for thorium; and it was not detected above laboratory reporting limits (<0.10 to <1.2 mg/L). Hence, radiological parameters are not proposed as part of the routine monitoring plan, as these constituents have not been identified above applicable MCLs. • Total Dissolved Metals — Piedmont Lithium is unclear regarding the request for "Total Dissolved Metals." In our experience, metals in water are typically evaluated as either total metals or dissolved metals. Given that the NCDEQ does not make regulatory decisions based on dissolved metals analytical data, Piedmont Lithium proposes to analyze and report total metals for the metals in Tables 1 and Table 3. • Microbiology/bacteria — There is no bacterial substrate proposed for placement in the waste rock pile. Unless there are exceedances of acceptable monitoring ranges, it is not anticipated that microbiology and bacterial testing would be necessary. • Nutrients — Ammonia nitrogen and nitrate/nitrite nitrogen, are listed as monitoring parameters. • Wet Chemistry — The monitoring parameters proposed herein include wet chemistry parameters suggested on the basis of monitoring parameters commonly required in mining applications, parameters listed in the NCG02 General Permit for Lithium Ore Mining, and the results of the humidity cell and LEAF test work. • Specific Conductance—Specific conductance is listed as a field parameter measurement. • Total Petroleum Hydrocarbons (TPH) — Per the NCO2 General Permit, non-polar oil & grease (TPH) is a required monitoring parameter for drainage areas that use > 55 gallons/month of oil on average for vehicle or equipment maintenance areas. The surface 9 Piedmont Lithium Carolinas,Inc. I Carolina Lithium Waste Rock Pile Monitoring and Treatment water basins are not capturing drainage from vehicle or equipment maintenance areas; therefore, TPH is not listed as a monitoring parameter. 10 Appendix D — Sediment Basin GCL Equivalency Page intentionally left blank. HDR Computation Job Number 10263685 No. 1 (Project PLI Mine Permitting (Computed PDB Date 8/28/2023 (Subject Sediment Basin Liner System Equivalency (Checked MDP Date 8/28/2023 (Task GCL versus 2 Ft of 1E-7 Clay (Sheet 1 10f 1 Objective: Evaluate the equivalency between a Geosynthetic Clay Liner(GCL)and Compacted Clay Liner under various pond head elevations to determine equivalency between the two systems. Background: The waste rock pile has 10 sediment basins around the perimeter that are designed to collect and manage the runoff from a 25-year, 24-hour storm event.These basins will act as the collection point for the erosion and sedimentation control runoff as well as the collection and treatment for contact water from the waste rock pile during operations. PLCI has decided to line the basins to enhance the environmental protection in areas where there will be hydraulic head build up and potential contact water treatment. The proposed basin liner system will consist of a 60-millimeter(mil) High Density Polyethylene(HDPE) membrane over a geosynthetic clay liner(GCL) liner of 1.1 x 10-9. In order to evaluate the proposed basin liner efficacy,an equivalency analysis must be performed between a compacted clay liner and a GCL to determine how the systems will perform under increasing head in the basins. Analysis: Using the EPA's Darcy Law of Gravity through Porous Media to demonstrate equivalency between a compacted clay liner and the selected GCL system was evaluated, which uses the hydraulic conductivity and thickness of the liner system against a variable hydraulic head value to establish the flowrate of each system at each stage of hydraulic head. Table 1:GCL vs.Clay Liner Equivalency at Increasing Head Table 2:Sediment Basin Head Elevations GCL Clay Liner Sediment Depth to Bottom of Pond Basin Normal Emergency k (cm/sec) 1.10E-09 1.00E-07 Pool Spillway t (cm) 0.6 60.96 SB-1 6.68 8.78 Pond SB-2 6 9.58 Depth In Pond Depth 6 mm GCL 2' Clay Liner SB-3 5.27 8.27 (ft) h (cm) q (cm/sec) q (cm/sec) pass/fail SB-4 5.52 8.52 1 30.5 5.70E-08 1.50E-07 pass SB-5 6.48 8.48 2.5 76.2 1.41E-07 2.25E-07 pass SB-6 6.51 8.41 5 152.4 2.81E-07 3.50E-07 pass SB-7 6.34 8.34 SB-8 7.45 8.45 7.5 228.6 4.20E-07 4.75E-07 pass SB-9 6.07 8.07 8 243.8 4.48E-07 5.00E-07 pass SB-10 5.88 7.88 10 304.8 5.60E-07 6.00E-07 pass 15 457.2 8.39E-07 8.50E-07 pass 20 609.6 1.12E-06 1.10E-06 fail Darcy's Law q=k((h/t)+1) q=flow rate per unit area (cubic centimeters/second) k=hydraulic conductivity of the liner (centimeters/second) h=hydraulic head above the liner(centimeters) t=thickness of the liner(centimeters) Conclusion: With the proposed basin liner configuration,the GCL and clay liner system is equivalent to a minimum of 15 feet of hydraulic head. The highest level of hydraulic head in the sediment basins occurs in SB-2 at the emergency spillway,where 9.58 feet of water ponds at the crest of the spillway (Table 2). Cross-referencing with the Darcy's Law analysis in Table 1,the systems maintain their equivalency at 10 feet of head, and would therefore function equivalently at the deepest ponding conditions in any of the ten sediment basins.The GCL functions better than clay at the worst case condition. Page intentionally left blank.