No preview available
HomeMy WebLinkAboutPKS 2022-2 Oversized PlansMIMOSA BLVD o. z EXIST R/R SP I KE" Ln Q c� n. Q 109 RAIN TANKS— ( TYP. ) PROPOSED LIMITS--- OF DISTURBANCE GENERATOR PAD ? .... k. v 3 Z co 0 c0 LAMA RUNOFF CONTAINMENT CALCULATIONS I LOT AREA 'WITHIN THE 75' AEC = 9,558.02 SF ALLOWABLE PERCENTAGE OF IMPERVIOUS AREA WITHIN THE 75' AEC = 30%, ALLOWABLE IMPERVIOUS AREA WITHIN THE 75AEC = 2,957.41 SF PROPOSED IMPERVIOUS AREA WITHIN THE 75' AEC = <SF PROPOSED IMPERVIOUS AREA IN EXCESS OF ALLOWABLE IMPERVIOUS AREA = SF RAIN FALL CONTAIN MENT REQUIREMENT = 2.00 F IN. RUNOFF FROM PROPOSED IMPERVIOUS AREA CONTAINMENT REQUIREMENT = 0.00 CF 4 RAIN TANK VOLUME = 4.22 CF NUMBER OF RAIN TANKS PROVIDED TO COMPLY WITH CAMA REGULATION = O TANKS 1 40 RAIN TANKS ( TYP. ) TOWN OF PINE KNOLL SHORES IMPERVIOUS AREA AND RUNOFF CONTAINMENTCALCULATIONS : TOTAL LOT AREA = 39,264.24 SF ALLOWABLE PERCENTAGE OF IMPERVIOUS AREA-- 35% ALLOWABLE IMPERVIOUS AREA = 13,742.48 SF PROPOSED IMPERVIOUS AREA = 9,048.36 SF PROPOSED IMPERVIOUS AREA (°l) = 23% RAINFALL CONTAINMENT REQUIREMENT = 2.00 1 N. RUNOFF FROM PROPOSED IMPERVIOUS AREA CONTAINMENT REQUI REMENT = 1,508.06 CF RAIN TANK VOLUME = 4.22 CF NUMBER OF RAIN TANKS PROVIDED TO COMPLY WITH TOWN OF PI NE KNOLL SHORES REGULATION 358 TANKS NOTE: EXISTING PELICAN DR, AND POOL DO NOTE REQUIRE RUNOFF CONTAINN1ENT EIS' SHEET # 1 OF 3 Y I - 1 RIM 4.25 I NV — 3 00 .,�—EX. BULKHEAD (NHW) 7 7 __7 BOGUE 'SOUND EMAG� OVERFLOW DOWNSPOUT (TYP. ) 4 ' P.V.C. MIN 75 / AEC LINE ---1 09 RAIN TANKS ( TYP . ) 'o r HVAC PAD /FOUNDATION HIGH POINT 105' -- 1,500 GAL. SEPTIC TANK -,—PROPOSED SEPTIC AREA 20' X45' �—PROPOSED SEPTIC REPAIR AREA 1 0' X45' t.� <r ©w cm U-) w U-)v o z �n (\Jw rn o Qr V)w LL Ll Il EIR ' END VIEW OF :PIPE/FABRIC CONNECTION'. CUT AN "X I`N THE FABRIC SLIGHTLY LARGER THAN PIPE, PULL THE FABRIC AROUND THE PIPE TO CREATE THE "BOOT" AND THEN SECURE WITH A HOSE —CLAMP. "X" CUT IN THE FABRIC TO ALLOW PIPE/TANK INTERFACE GEOTEXTILE FABRIC OVER D—RAIN,TANK* NON —CORROSIVE HOSE CLAMP OR TAPE USED TO FASTEN LINER TO PIPES TO PREVENT BACKFILL FROM ENTERING STRUCTURE \—INLET/OUTLET FAABRIC OVER PIPE VE R PIPE FC. RAINTANK+ GEOTEXTILE FABRIC RAINTANK INLET/OUTLET DETAIL 1 WITH OPTIONAL ALE' NCONNECTOR PLATE TS POUT FOR INAGE IVERFLOW DOWN SPOUT (NTS) PLAN VIEW 28.15" SIDE VIEW GEOMETRY:LENGTH = 28.15IN WIDTH = 15.75 IN HEIGHT = 17.32 IN STORAGE VOLUME = 4,22 CF VOID INTERNAL VOLUME: 95% VOID SURFACE AREA: 95% FRONT VIEW ISOMETRIC VIEW DIMENSIONS SHOWN ARE NOMINAL, REFER TO MODULE DATA FOR CONCEPTUAL ASSEMBLY, SEE EXPLODED VIEW FOR SINGLE SINGLE MODULE MODULE DATA 34 PSI, (MODULE ONLY) !LOAD RATING: H-20, (WITH ACF COVER SYSTEM) (MATERIAL: 85% RECYCLED POLYPROPYLENE NOTES: 1, FIRM NUMBER: 3720635500 EFFECTIVE DATE: 7/16/2003 SITE IS LOCATED IN AE-C AND SHADED-X FLOOD ZONE 2. IF CONSTRUCTED AS DES IGNED9 THIS SYSTEM WILL RETAIN AND INFILTRATE THE REQUISITE VOLUME OF STORMWATER RUNOFF AND ANY GRADE ELEVATION CHANGES OR CONSTRUCTION ON THE SITE WILL NEITHER INCREASE THE RATE OF FLOW, NOR THE VOLUME OF WATER DISCHARGED ON TO THE ADJACENT PROPERTIES. REVISIONS: Na BY DATE DESCRIPTION SITE AND GRADING PLAN PINE KNOLL SHORES TWSP°, CARTERET COUNTY, NORTH CAROLIN CLIENT: RUSTY MAY HOMES DESIGNED: HD ADDRESS: PO BOX 1136 DRAWN: HAMPSTEAD, NC 28443 HD e 4 sl;'', PHONE: CHECKED: CmC a SE �C JIE,IL�IPII�IE]E� C]ROU P, P.A. APPROVED: - 3737t3 ENGINEERING & SURVEYING SERVICES CMC C� 151A HIGHWAY 24 DATE' MOREHEAD CITY, N.C. 28557 ° -4\ i� (, 52) 7�" 3-0090 1 1 L SENSE NO. C 4482 1 /1 1 /2022 \ 2 — - ' ',. SCALE: z CHARLES M. Ct P ER F.E. 1 ,, = 20' r"�"Zo2Z