Loading...
HomeMy WebLinkAbout71-10 OVERSIZE PLANSNOTES: 1. OWNER: LOUIS A. JR, & PATRICIA W. NASSEF 63 OVERLOOK DRIVE DANVILLE, PA 17821 C/O MIKE GOLTRA 2. ENGINEER: QUIBLE & ASSOCIATES, P.C. P.O. DRAWER 870 KITTY HAWK, NC 27949 3. RECORDED REFERENCE: DB. 1023, PG. 635: D.B. 1697, PG. 22 BCR 4. PROPERTY IS CURRENTLY LOCATED IN F.I.R.M. ZONE AE (EL 10.0') (SUBJECT TO CHANGE BY F.E.M.A.) 5. PARCEL AREA: PIN: 5694-53-6138 a 8.260 SQ.FT. (0.19 ACRES) PIN: 5693-53-7202 5,792 SQ.FT. (0.13 ACRES) TOTAL AREA - 14,052 SQ.FT. (0.32 ACRES) 6. SEPTIC SYSTEM: ACTIVE SYSTEM: 1) DESIGN FLOW.- 6 PERSON SLEEPING CAPACITY O 60 GPO / PERSON = 360 GPD 2) LONG TERM APPLICATION RATE (LTAR): ACTIVE = 1.0 GPD/SF 3) ACTIVE: PURAFLO 810FILTRATION SYSTEM - 360 SF (REDUCTION IN HORIZONTAL SETBACK UTILIZED FROM PAMLICO RIVER) 4) UTILIZE 15A .1945 RULE (NO REPAIR AREA SHOWN) 5) UTILIZE 15A .1951 RULE (REDUCED SETBACKS FROM PROPERTY LINE) 115A .1950 (12)1 9. COVERAGE PROPOSED COVERAGE: HOUSEAND DECKS............................................................................................... 3,077.21 SQ.FT. TOTAL - 3,077,21 SQ.FT. BEAUFORT COUNTY COVERAGE - ( 3077 SQ.FT./ 14,052 SQ.FT.) x 100 - 21.9% PROPOSED COVERAGE WITHIN 50' TAR PAM BUFFER: PURAFLOPEAT UNITS................................................................................................ 40.9 SQ.FT. TOTAL - 40.9 SQ.FT. 7. SETBACKS SHOWN ARE AS PER BEAUFORT COUNTY AND MUST BE VERIFIED. THEY DO NOT REFLECT ANY RESTRICTIVE COVENANTS THAT MAY EXISTS. WASTEWATER SYSTEM NOTES 1. CONTRACTOR IS RESPONSIBLE FOR LOCATING EXISTING UNDERGROUND UTILITIES IN AREAS OF WORK PRIOR TO ANY WORK. PROVIDE ADEQUATE MEANS OF SUPPORT AND PROTECTION IF UTILITIES ARE TO REMAIN IN PLACE. 2. REMOVE TREES, GRASSES, SHRUBS AND OTHER VEGETATION, IMPROVEMENTS OR OBSTRUCTIONS INTERFERING WITH INSTALLATION OF NEW CONSTRUCTION UNLESS NOTED OTHERWISE. 3. NEW WASTEWATER SYSTEM DESIGN PARAMETERS: ,6CTIVE SYSTEM: DESIGN FLOW: 6 PEOPLE O 60 GALLONS PER DAY (GPD) PER PERSON - 360 GPD LONG TERM APPLICATION RATE (LIAR): 1.0 GPD/SQ.FT. FOR A PEAT BIOFILTRATION SYSTEM AS SET BY THE BCHD. UTILIZE (REDUCTION IN HORIZONTAL SETBACK (NO REDUCTION IN BED AREA) 4. UNLESS OTHERWISE INDICATED ON THE PLAN, CONSTRUCTION OF SEWAGE COLLECTION, TREATMENT AND DISPOSAL SYSTEM IS TO CONFORM WITH SECTION .1900 "LAWS AND RULES FOR SEWAGE TREATMENT AND DISPOSAL SYSTEMS" OF NORTH CAROLINA ADMINISTRATIVE CODE, DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCE$ DIVISION OF ENVIRONMENTAL HEALTH, ON -SITE WASTEWATER SECTION (15 NCAC 18A.1900) AND INNOVATIVE APPROVAL IWWS-98-R3. 5. CONSTRUCTION OF SEWAGE COLLECTION SYSTEM, TREATMENT AND DISPOSAL SYSTEM IS To CONFORM WITH ANY CONDITIONS IMPOSED BY THE LOCAL HEALTH DEPARTMENT. 6, MATERIAL USED FOR COLLECTION AND DISPOSAL SYSTEM SHALL CONFORM WITH SAME REQUIREMENTS AS 04 ABOVE. 7. FILL MATERIAL SHALL HAVE SUCH SOIL TEXTURE TO BE CLASSIFIED AS SAND OR LOAMY SAND (SOIL GROUP 1) UP TO THE TOP OF THE NITRIFICATION TRENCHES. THE FINAL SIX INCHES OF FILL USED TO COVER THE SYSTEM SHALL HAVE A FINER TEXTURE (SUCH AS GROUP If. III) FOR THE ESTABLISHMENT OF A VEGETATIVE COVER, THE FILL MATERIAL AND THE EXISTING SOIL SHALL BE MIXED TO A DEPTH OF SIX INCHES BELOW THE INTERFACE. HEAVY VEGETATIVE COVER OR ORGANIC LITTER SHALL BE REMOVED BEFORE THE FILL MATERIAL IS INCORPORATED. 8. WELL POINTS AND PUMPS SHALL BE SUFFICIENT IN SIZE AND SPACING TO DRAW DOWN WATER TABLE TWO TO THREE FEET BELOW REQUIRED EXCAVATION FOR SEPTIC AND PUMP TANKS. 9. GRADES SHALL BE ESTABLISHED TO DIVERT RUNOFF AWAY FROM TANKAGE. FINAL GROUND ELEVATION ABOVE TANK SHALL BE AS INDICATED ON THE DETAIL SHEETS. 10. ALL SURFACE RUNOFF SHALL BE DIVERTED AROUND AND AWAY FROM THE DRAINFIELD AREA. FINISH GRADE SHALL BE LANDSCAPED TO PREVENT PONDING OF SURFACE WATER. VEGETATE DRAINFIELD AREA AS SPECIFIED IN LANDSCAPE PLAN (BY OTHERS). ALL DRAINFIELD AND REPAIR AREAS SHALL BE SEEDED AND MULCHED ACCORDING TO THE FOLLOWING SPECIFICATIONS: PERMANENT VEGETATION TEMPORARY VEGETATION SEEDING DATES: APRIL 1- SEPT 30 SEEDING DAIFS: OCT. 1 --MARCH 31 SEED MIXTURE APPUCARON RATES/ACRE SEED MIXTU_kE APPLICATION RATES/ACRE BAHIA 30 LBS.. RYE GRAIN 175 LBS. COMMON BERMUDA 50 LOS. (UNHULLED) FIER-�nR GERMAN MILLETT 15 LB& 10-10-10 O 750 LB/ACRE FESCUE 20 LBS. MULCH FERTILIZER 10-1G-10 O 500 LB/ACRE APPLY 4.000 LB. STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL A DISK WITH BLADES SET NEARLY MULCH STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT NETTING. OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL GENERAL SEEDING SPECIFICATIONS BOUNDARY/SITE PLAN INFORMATION TAKEN FROM SITE PLAN BY DANIEL LYNN COCHRAN DESIGN (511 WEST 2ND STREET, WASHIN(TON, NC 27889 - 252-362-0147) OBTAINED IN ELECTRONIC FORMAT FILE: A1.NassefSitePIan.DWG. DRAWING FILE: P10006-BASE.DWO PLOT SCALE: 1:20 feat Biofilter far Wastewater Treatment Single House Installation Biofilter Modules on Stone Drainfield Gravity Line from House Effluent Filter Treated Wastewater Percolates into Soil Under the System Septic Tank Pump Tank E 6LENHAVEN Ro r--, I I I I -1 I I I L 1 I N/r I PATRIG/A D. H. ]'ANKARD D.B. 1013, P6. 652 PIN: 5694-53-5262 r I I I I 1 '---_j r I I JI 50' TAR-PAM B VIEuPLAN� (MUST BE VERIFIED) PLANS TO BE USED FOR THE CONSTRUCTION/ INSTALLATION OF THE WASTEWATER SYSTEM ONLY. �P N/F KfZRAYN. t .5TAGYR. LYNGN D.S. 1697, P6. 823 PIN. 5594-63-5164 FAML ICO FI VEF ('5W' HA TER CL A55IF16ATIONI GRAPHIC SCALE 20 0 10 20 b ( IN FEET ) I Inch = 20 ft. C N W � a e h � I �I HURRAY N t 9 AGY R. LY1415N PIN M14-63-5961 (MUST BE VERIFIED) 35' BUFFER 7JREDCiE0 SETBACK FOR UWASTEWATER SYSTEM) S�• 4g ` SR1354 4" 4• j SR1350 E� • eA`• N� H E•' wy 3E SPI317 .•„ ,� SR1318 qD 3fti3�+F, �. SITE VICINUY MAP N.T.S. LIRGEND C t. t ?'�LTd" Pr��yy €(,: PROPOSED GRAVEL FOR WASTEWATER SYSTEM ® EXISTING IRON IN CONCRETE i) EXISTING GROUNDWATER WELL EXISTING WATER METER EXISTING TREE AS SHOWN ON SITE PLAN BEFORE YOU DIG ! I CALL TOLL FREE 1-800-632-4949 IORTN CAROLINA ONE CALL TE. THE DATA GIVEN ON THESE PLANS IS BELIEVED 10 BE ACCURATE, BUT THE ACCURACY IS NOT GUARANTEED. THE CONTRACTOR IS RESPONSIBLE 10R VERIFYING ALL LEVELS, LOCATIONS, TYPES, AND DIMENSIONS OF THE EXISTING UTILITIES PRIOR TO CONSTRUCTION. IF A DISCREPANCY IS FOUND, WORK SHALL CEASE AND THE ENGINEER NOTIFIED. WORK MAY CONTINUE UPON ENGINEERS NOTICE TO PROCEED. • zz S z- F`•'1 g 6 tl n Z1nI y JU ai "n tvZ .. to '�► � U Fd} n w® g�W w S 0 11111111 COMNSSION NO. P10006 DESIGNED BY JJA TAS DRAWN BY TAS CHECKED BY JJA ISSUE DATE 4/5 10 SHEET NO. OF 2 SHEETS