Loading...
HomeMy WebLinkAbout5-23 M&R1 /12/23 Katydids at 2025 LLC 101 WOLVERINE RD CARY, NC 27513 Exemption Number — 5-23 M&R RE: EXEMPTED PROJECT - MAINTENANCE AND REPAIR of STRUCTURES CONSISTENT WITH CURRENT RULES [15A NCAC 07K .0209(c)] PROJECT ADDRESS — 2025 W Beach Dr AREA OF ENVIRONMENTAL CONCERN - OE Dear Sir: I have reviewed the information submitted to this office in your inquiry concerning the necessary filing of an application for a minor development permit under the Coastal Area Management Act. After making a site inspection on 1/12/23, 1 have determined that the activity you propose is exempt from needing a minor development permit as long as it remains consistent with your site drawing and materials list submitted on 1112/23, and meets the conditions specified below. If your plans should change and your project will no longer meet these conditions, please contact me before proceeding. MAINTENANCE AND REPAIR — [15A NCAC 7K .0209(c)] - Any structure, or part thereof, consistent with current CRC rules may be maintained, repaired or replaced in a similar manner, size and location as the existing structure without requiring a permit, unless the repair or replacement would be in violation of the criteria set out below. This exemption applies to those projects that are not within the exclusion for maintenance and repairs as set out in G.S. 113A-103(5)b.5., Rule .0103 of this Subchapter and Rule 07J .0210. 1. the development must not disturb a land area of greater than 200 square feet on a slope of greater than 10 percent; 2. the development must not involve removal, damage, or destruction of threatened or endangered animal or plant species; Development Services 4601 E. Oak Island Drive • Oak Island, North Carolina 28465 Phone: (910) 278-5024 - Fax: (910) 278- 1811 • Website: www.oakislandnc.com 3. the development must not alter naturally or artificially created surface drainage channels; 4. the development must not alter the land form or vegetation of a frontal dune; 5. the development must not be within 30 feet of normal water level or normal high water level; and, 6. development must be consistent with all applicable use standards and local land use plans in effect at the time the exemption is granted. Structures may be repaired in a similar manner, size and location as the original structure. No expansions or additions are permissible and the following specific conditions apply: 1. The project consists of the repair of pilings, as shown on the attached drawing and materials list. 2. The proposed repairs shall be consistent with all other applicable local ordinances and North Carolina Building Code standards. This exemption to CAMA permit requirements does not alleviate the necessity of your obtaining any other State, Federal or Local authorization and N.C. Building Permits. This exemption expires 90 days from the date of the letter. Sincerely, Courtney Milliron, LPO Town of Oak Island Cc: DCM Field Representative — Patrick Amico 2 CAMA MINOR PERMIT PROGRAM ❑ MODIFICATION ❑ EXEMPTION W1 MAINTENANCE AND REPAIR Locality: Permit # 5-23 M&R CAMA Minor Permit Office Date previous As authorized by the State of North Carolina permit issued per the Coastal Area Management Act of 1974 Applicant Name Katydids at 2025 LLC Address 101 WOLVERINE RD City CARY, NC 27513 Phone # 919-625-3467 Authorized Agent Todd Snyder I Type of Project Uescrl tion of Replace pilings Notes or special conditions: $14,000.00 Katydids at 2025 LLC Owner's Name (Print) Signature (owner or agent) Project Location Information Street Address 2025 W. Beach Dr. Adj. Water Body Atlantic Ocean AEC: ❑ CS ❑✓ OE ❑ IH See attached site plan Project Drawing i LPO Signature Iss ance Dat Ex . Date w a_ V) ILL. w a w Ej w z� 0 c� a� is a �w ,r w=) m C3 w oa t- NEW PT M PILJNG CONNECT EACH NEW PT (ROUGH) PILING TO EXISTING PT (ROUGH) PILING USING 8, 31eO GALVANIZED STEEL BOLTS (A307) AND ACCEPTABLE OVERSIZED WASHERS. CONTRACTOR SHALL REPAIR GALVANIZED STEEL USING A ZINC -RICH PAINT IN THE FIELD AS REQUIRED TO PREVENT FUTURE CORROSION. (TYPICAL) o i I J-----1. _L 4" 4" 8' (ELEVATION VIEW) 0 0 0 0 0 0 0 0 i I t I �I I � I �L. 2" 8" (ELEVATION VIEW) GENERAL NOTES: GENERAL CONTRACTOR SHALL RE-ROUTE ALL HVAC AND/OR UTILITIES WITHIN AREA & FRAMING, AS REQUIRED. (TYPICAL) GENERAL CONTRACTOR TO REMOVE AND REPLACE ALL OTHER EXISTING MEMBERS AT THEIR DISCRETION BASED ON MATERIAL DEGRADATION AND/OR AS -FOUND CONDITION PRIOR TO AND DURING CONSTRUCTION. (TYPICAL) GENERAL CONTRACTOR SHALL ENSURE THE EXISTING STRUCTURE & FRAMING MEMBERS THAT WILL REMAIN ARE ADEQUATELY SHORED/BRACED AS REQUIRED. (TYPICAL) ALL OTHER FRAMING AND/OR CONSTRUCTION NOT SHOWN ON THESE CONSTRUCTION DRAWINGS IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SHALL COMPLY WITH THE LATEST EDITION OF THE NORTH CAROLINA BUILDING CODE (RESIDENTIAL) TYPICAL PT BxB TIMBER PILE SPLICE CONNECTION DETAIL NOTE: THIS DETAIL IS APPLICABLE FOR ABOVE CRQUND LEVEL AT NO MORE THAN SIX PILE LOCATIONS AT THE REFERENCED PROJECT ADDRESS (TYPICAL) NOTE: AS AN ALTERNATIVE, IT IS ACCEPTABLE TO USE GRADE J04 OR GRADE 316 STAINLESS STEEL BOLTS/NUTS/WASHERS (TYPICAL) PAGE I OF 1 NOT TO SCALE CONTRACTOR TO REMOVE DEGRADED PORTIONS OF EXISTING PILING BELOW NATURAL GRADE AS REQUIRED TO IMPLEMENT DETAILS AS SPECIFIED HEREIN, IF APPLICABLE ONLY J R ®ICKERSON ENGINEERING, PLLC NORTH CAROLINA LICENSE NO. P-0994 6505 FuNSTON ROAD SE WINNASOw, NORTH CAROLINA 28479 (910) 297-7374 CARo • SEAL { 5 ;2 cam•. - ... 12 t'2I 2022 TITLE: 2025 WEST` BEAC�4 DRIVE OAK ISLAND BrluNswlCK CouNTY, NO PROJECT No.: 22245 DATE: 1 2 / 27 / 22 1 SHE= No.: S 1 .❑ 1