HomeMy WebLinkAbout5-23 M&R1 /12/23
Katydids at 2025 LLC
101 WOLVERINE RD
CARY, NC 27513
Exemption Number — 5-23 M&R
RE: EXEMPTED PROJECT - MAINTENANCE AND REPAIR of
STRUCTURES CONSISTENT WITH CURRENT RULES [15A NCAC
07K .0209(c)]
PROJECT ADDRESS — 2025 W Beach Dr
AREA OF ENVIRONMENTAL CONCERN - OE
Dear Sir:
I have reviewed the information submitted to this office in your inquiry concerning
the necessary filing of an application for a minor development permit under the
Coastal Area Management Act. After making a site inspection on 1/12/23, 1 have
determined that the activity you propose is exempt from needing a minor
development permit as long as it remains consistent with your site drawing and
materials list submitted on 1112/23, and meets the conditions specified below. If
your plans should change and your project will no longer meet these conditions,
please contact me before proceeding.
MAINTENANCE AND REPAIR — [15A NCAC 7K .0209(c)] - Any structure, or part
thereof, consistent with current CRC rules may be maintained, repaired or
replaced in a similar manner, size and location as the existing structure without
requiring a permit, unless the repair or replacement would be in violation of the
criteria set out below. This exemption applies to those projects that are not within
the exclusion for maintenance and repairs as set out in G.S. 113A-103(5)b.5.,
Rule .0103 of this Subchapter and Rule 07J .0210.
1. the development must not disturb a land area of greater than 200
square feet on a slope of greater than 10 percent;
2. the development must not involve removal, damage, or destruction of
threatened or endangered animal or plant species;
Development Services
4601 E. Oak Island Drive • Oak Island, North Carolina 28465
Phone: (910) 278-5024 - Fax: (910) 278- 1811 • Website: www.oakislandnc.com
3. the development must not alter naturally or artificially created surface
drainage channels;
4. the development must not alter the land form or vegetation of a frontal
dune;
5. the development must not be within 30 feet of normal water level or
normal high water level; and,
6. development must be consistent with all applicable use standards and
local land use plans in effect at the time the exemption is granted.
Structures may be repaired in a similar manner, size and location as the original
structure. No expansions or additions are permissible and the following specific
conditions apply:
1. The project consists of the repair of pilings, as shown on the attached
drawing and materials list.
2. The proposed repairs shall be consistent with all other applicable local
ordinances and North Carolina Building Code standards.
This exemption to CAMA permit requirements does not alleviate the necessity
of your obtaining any other State, Federal or Local authorization and N.C.
Building Permits. This exemption expires 90 days from the date of the letter.
Sincerely,
Courtney Milliron, LPO
Town of Oak Island
Cc: DCM Field Representative — Patrick Amico
2
CAMA MINOR PERMIT PROGRAM
❑ MODIFICATION ❑ EXEMPTION W1 MAINTENANCE AND REPAIR
Locality: Permit # 5-23 M&R
CAMA Minor Permit Office Date previous
As authorized by the State of North Carolina permit issued
per the Coastal Area Management Act of 1974
Applicant Name Katydids at 2025 LLC
Address 101 WOLVERINE RD
City CARY, NC 27513
Phone # 919-625-3467
Authorized Agent Todd Snyder I
Type of Project
Uescrl tion of
Replace pilings
Notes or special
conditions:
$14,000.00
Katydids at 2025 LLC
Owner's Name (Print)
Signature (owner or agent)
Project Location Information
Street Address 2025 W. Beach Dr.
Adj. Water Body Atlantic Ocean
AEC: ❑ CS ❑✓ OE ❑ IH
See attached site plan
Project Drawing
i
LPO Signature
Iss ance Dat Ex . Date
w
a_
V)
ILL.
w
a
w
Ej
w
z�
0
c�
a�
is
a
�w
,r
w=)
m C3
w
oa
t-
NEW PT M PILJNG
CONNECT EACH NEW PT (ROUGH) PILING
TO EXISTING PT (ROUGH) PILING USING
8, 31eO GALVANIZED STEEL BOLTS (A307)
AND ACCEPTABLE OVERSIZED WASHERS.
CONTRACTOR SHALL REPAIR GALVANIZED STEEL
USING A ZINC -RICH PAINT IN THE FIELD
AS REQUIRED TO PREVENT FUTURE CORROSION.
(TYPICAL)
o
i I
J-----1. _L
4" 4"
8'
(ELEVATION VIEW)
0 0
0 0
0 0
0 0
i I t I
�I I
� I
�L.
2"
8"
(ELEVATION VIEW)
GENERAL NOTES:
GENERAL CONTRACTOR SHALL
RE-ROUTE ALL HVAC AND/OR
UTILITIES WITHIN AREA &
FRAMING, AS REQUIRED.
(TYPICAL)
GENERAL CONTRACTOR TO
REMOVE AND REPLACE ALL
OTHER EXISTING MEMBERS AT
THEIR DISCRETION BASED ON
MATERIAL DEGRADATION AND/OR
AS -FOUND CONDITION PRIOR TO
AND DURING CONSTRUCTION.
(TYPICAL)
GENERAL CONTRACTOR SHALL
ENSURE THE EXISTING STRUCTURE
& FRAMING MEMBERS THAT
WILL REMAIN ARE ADEQUATELY
SHORED/BRACED AS REQUIRED.
(TYPICAL)
ALL OTHER FRAMING AND/OR
CONSTRUCTION NOT SHOWN ON
THESE CONSTRUCTION DRAWINGS
IS THE RESPONSIBILITY OF THE
GENERAL CONTRACTOR AND
SHALL COMPLY WITH THE LATEST
EDITION OF THE NORTH CAROLINA
BUILDING CODE (RESIDENTIAL)
TYPICAL PT BxB TIMBER
PILE SPLICE CONNECTION DETAIL
NOTE:
THIS DETAIL IS APPLICABLE
FOR ABOVE CRQUND LEVEL
AT NO MORE THAN SIX PILE LOCATIONS
AT THE REFERENCED PROJECT ADDRESS
(TYPICAL)
NOTE:
AS AN ALTERNATIVE, IT IS
ACCEPTABLE TO USE GRADE J04
OR GRADE 316 STAINLESS STEEL
BOLTS/NUTS/WASHERS (TYPICAL)
PAGE I OF 1
NOT TO SCALE
CONTRACTOR TO
REMOVE DEGRADED PORTIONS
OF EXISTING PILING BELOW
NATURAL GRADE AS REQUIRED
TO IMPLEMENT DETAILS
AS SPECIFIED HEREIN,
IF APPLICABLE ONLY
J R ®ICKERSON ENGINEERING, PLLC
NORTH CAROLINA LICENSE NO. P-0994
6505 FuNSTON ROAD SE
WINNASOw, NORTH CAROLINA 28479
(910) 297-7374
CARo
• SEAL {
5 ;2
cam•. - ...
12 t'2I 2022
TITLE:
2025 WEST` BEAC�4 DRIVE
OAK ISLAND
BrluNswlCK CouNTY, NO
PROJECT No.: 22245
DATE: 1 2 / 27 / 22 1 SHE= No.: S 1 .❑ 1