Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutNTB_16-28_MoranILM
1160.
Coastal Management
ENVIRONMENTAL QUALITY
November 14, 2016
Shelia Moran
4002 Island Drive
North Topsail Beach, NC 28460
RE: EXEMPTED PROJECT (MINOR) EXEMPTION
STRUCTURE (15A NCAC 7K .0209) — Exemption# NTBEXI6-28
4002 Island Drive, North Topsail Beach, NC
AREA OF ENVIRONMENTAL CONCERN — Ocean Hazard AEC
Dear Mr. Moran:
PAT MCCRORY
Governor
DONALD R. VAN DER VAART
Secremry
BRAXTON DAVIS
Director
I have reviewed the information submitted to this office in your inquiry concerning the necessary filing of an
application for a minor development permit under the Coastal Area Management Act. Based on the information
provided, I have determined that the activity you propose is exempt from needing a minor development permit as
long as it remains consistent with your site drawing dated received by DCM on 11/10/16, and meets the
conditions specified below. If your plans should change and your project will no longer meet these conditions,
please contact me before proceeding.
ACCESSORY STRUCTURE
1. The development specifically authorizes the work detailed in the site plan dated received by the
Division of Coastal Management 11/10/16, to include construction of a 6' x 6' sq, ft. elevator
along the street side of the residence. Any additional development not illustrated on the
referenced site plan will require re-evaluation by the Division of Coastal Management.
2. The development must not involve removal, damage, or destruction of threatened or endangered
animal or plant species.
3. The development must not alter naturally or artificially created surface drainage channels.
4. The development must not alter the land form or vegetation of a frontal dunes.
5. The development must be consistent with all applicable use standards and local land use plans in
effect at the time the exemption is granted.
6. The proposed development shall remain consistent with the attached work plan drawings.
7. The development must be setback behind (landward) of the First Line of Stable Natural
Vegetation (FLSNV), and behind (landward) of the landward toe of the frontal dune.
This exemption to CAMA permit requirements does not alleviate the necessity of your obtaining any other State,
Federal or Local authorization. This exemption expires 90 days from the date of the letter.
c'rely,
on D 1l, LPO
C.
Tame Woodle — North Topsail Beach
State of North Carolina I Enviromnemal Quality I Coastal Management
127 Cardinal Drive ExL, Wilmington, NC 29405
910-796-7215
EXISTING
FIRST
CONDITIONED
FLOOR
EXISTING
PORCH POST
WITH B' MIN.
EMBEDMENT
(ASSUME)
i
XIST.
SECTION A -A
SCALE
EXISTING
ROOF TO
REMAIN
MIN. 2-2xB GIRDER
9�
I��
o$
0
MIN. 2-2x8 GIRDER
2x4 PT FRAMING
'TTPICAL 16' O.C.
SEE PLAN FOR
PROPOSED WALL
ATTACHMENT TO
EXISTING
PILE/WALL
FRAMING.
---4,
ELEVATOR CAR
PER MANUF.
SPECS. VERIFY
s
O
I
IXl
91A ANCHOR ASSURE A MIN.
'H
OF 2 ANCHOR I >i
—EDGE OF CONCRETE FOOTING
OFOUNDATION DETAIL
SCALE. 1 /4'-1'-0'
ER TO DETAIL & TYPICAL AT
XR HEADER/ DECK CONNECTIONS.
;/////,
OFRAMING DETAIL
SCALE 1/4'-7'-0'
��S-7"
2'-4.,
3b'x4'0'
ELEVATOR
CAR PER
MANUF.
SPECS
////// A
EXISTING RESIDENCE/
SIDING PER OWNER. TREATED SHEATHING.
4G OPTION TO 'FURR QUY WALL TO ALIGN WITH
OF EXISTING PORCH IS ACCEPTABLE CONFIRM.
WTM OWNER/CONTRACTOR.
2x4 SVP 0/22 O 16- O.C. FRAME
WALL. TYP UNLESS NOTED
OTHERWISE .7REA7M ,MATERIALS
SECURE,NEW 2-2x4 STUDS AT -91
CORNERS USING 3(e-6'-LONG 8
LAG BOLTS O 12' O.C. INTO
EXISTING STUDS ASSURE A MN. _.
2-2x4 STUD COLUMN IN H
EXISTING WALL AT LAG BOLT
ATTACHMENT LOCATIONS.
FIRST FLOOR EXISTING SLIDER ON ROAD SIDE
TO BE PARTIALLY 'FRAMED IN' FOR ELEVATOR
DOOR OPENING. WINDOW SHALL BE INSTALLED
ON RIGHT WALL FOR EGRESS.
ON SECOND LEVEL, EXISTING WINDOW WALL BE
CONVERTED TO DOOR OPENING FOR ELEVATTO&
ELEVATOR FRAMING PLAN
SCALE: 1/4'=1'-0'
�ALL DIMENSIONS ARE 70 BE VERIFIED BY OWNER/CONIRACTOR4 PRIOR
1OR TO CONSTRUCTION.
ADJUST HEIGHTS AND WIDTHS AS REQUIRE. NO WINDOWS OR EXTERIOR DOORS IN ADDITION.
2- THIS DESIGN IS STE SPECIFIC AND INTENDED TO SHOW AN ELEVATOR ADDITION DESIGN FOR AN
EXISTING STRUCTURE
3 - ONLY USE MATERIALS BELOW FLOOD BFE THAT ARE EITHER TREATED OR MOISTURE RESISTANT.
4- IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND/OR BUILDER TO CONFORM TO ALL
STANDARDS OF THE NC BUILDING CODE. VERIFY ALL DIMENSION PRIOR TO CONSTRUCTION.
5- LUMBER IS SPECIFIED AS 12 SYP, AT IDS MOISTURE LVL'S ARE DESIGNED WITH F4-2950 PS
AND E-2.04P
6- TIEDOWNS BY SIMPSON
7- ALL EXPOSED MATERIALS MUST BE TREATED PER CODE
8- THESE PLANS COMPLIMENT AN COSTING STRUCTURE
9- ALL DIMENSIONS SHOWN ARE APPROXIMATE. ELEVATOR DIMENSIONS TO NOT EXCEED 6' OF
SHOWN ON PLANS. DIMENSIONS 70 BE VERIFIED & ADJUSTED IN FIELD.
10- PROVIDE ADEQUATE ELECTRIC SERVICE TO EQUIPMENT PER NEC AND NCBC AND MANUF.
SPECS. ASSURE ELECTRIC SERVICE INSTALLATION BY LICENSE ELECTRICAL CONTRACTORS.
11- RECEIPT OF THESE PLANS BY OWNER/CONTRACTOR AND ALL OTHERS ACKNOWLEDGE THEY
ACCEPTTHISPLAN IN EVERYWAY TO BE CORRECT._ ANY DISPUTE OR CORRECTION MUST BE
ADDRESSED PRIOR TO CONSTRUCTION.
12- REFERENCE PLANS BY CUSTOM ELEVATOR MANUFACTURING COMPANY, INC. DRAWING /
REAL-16591 FOR ELEVATOR SPECS. ALL REFERENCED PLANS WERE SUPPLIED BY OTHERS
13- ASSURE CONTINUOUS BLOCKING TO FOUNDATION AT POINT LOAD LOCATIONS.
14- OSHA REGULATIONS WERE NOT TAKEN INTO CONSIDERATION FOR THIS DESIGN. CONTRACTOR
SHALL VERIFY ALL REGULATIONS AND CONFIRM ANY POTENTIAL HAZARDS PRIOR TO CONSTRUCTION.
EXP. D
ANY WAY WITHOUT THE EXPRESS CONSENT OF WESTON
LYALL, PE, PLS, PLLC. ANY PARTY THAT TAKES PART I
WESTON LYALL, PE, PLS, PLLC I
ELEVATOR ADDITION
FRAMING & DETAILS
WESTON LYALL, PE,' PLS. PLLC
214 US HIGHWAY 17N. SUITE. 1
HOLLY RIDGE, NO. 28445
PHONE: 910.329-9961
FIRM AP-0937
k
1
rl�
N`�� N NOV 10 HIS