Loading...
HomeMy WebLinkAboutSC_17-18_ Murdock (2) l" -i I Issued by WiRO SC17-18 Surf City Permit Number CAMA MINOR DEVELOPMENT PERMIT Coastal Management ENVIRONMENTAL QUALITY as authorized by the State of North Carolina, Department of Environmental Quality and the Coastal Resources Commission for development in an area of environment concern pursuant to Section 113A-118 of the General Statutes, "Coastal Area Management" Issued to Daniel Murdock authorizing development in the Estuarine Shoreline (AEC) at 7063 7th Street, in Surf City, Onslow County as requested in the permittee's application, dated November 9, 2017, and received by DCM on November 14, 2017. This permit, issued on November 27, 2017, is subject to compliance with the application and drawing dated and received by DCM on November 14, 2017 (where consistent with the permit), all applicable regulations and special conditions and notes set forth below. Any violation of these terms may subject the permittee to a fine, imprisonment or civil action, or may cause the permit to be null and void. This permit authorizes: Residential home construction. (1) All proposed development and associated construction must be done in accordance with the permitted site drawing dated received by DCM on November 14, 2017. (2) Any change or changes in the plans for development, construction, and/or land use activities will require re-evaluation and modification of this permit. (3) A copy of this permit shall be posted or available on site throughout the construction process. Contact this office at (910) 766-7221 for a final inspection at completion of work. (Additional Permit Conditions on Page 2) This permit action may be appealed by the permittee or other qualified persons within twenty (20) days of the issuing date. This permit must be on the project site and accessible to the permit officer when the project is inspected for Jason Dail compliance. Any maintenance work or project modification not covered under CAMA LOCAL PERMIT OFFICIAL this permit,require further written permit approval.All work must cease when this permit expires on: 127 Cardinal Drive Extension December3l,2020 Wilmin ton, C 28405-38 5 In issuing this permit it is agreed that this project is consistent with the local Land j CI Use Plan and all applicable ordinances. This permit may not be transferred to another party without the written approval of the Division of Coastal PERMITTEE Management. (Signature required if conditions above apo ,e, A „ Name: Daniel Murdock Minor Permit#SC17-18 Date: November 27, 2017 Page 2 of 3 (4) All unconsolidated material resulting from associated grading and landscaping shall be retained on site by effective sedimentation and erosion control measures. Disturbed areas shall be vegetated and stabilized (planted and mulched)within 14 days of construction completion. (5) Any proposed for grading within the 30' buffer from the Normal High Water level must be contoured to prevent additional stormwater runoff to the adjacent marsh and/or canal. This area shall be immediately vegetated and stabilized, and must remain in a vegetated state. (6) All development shall be located at least 30 feet landward of the normal high water line. (7) This permit does not authorize the excavation or filling of any wetlands,even temporarily. (8) No impervious coverage/built upon area, including but not limited to the house (including eaves), foundation pad, covered decking,etc.shall extend into the 30-foot coastal shoreline buffer. (9) All structures shall comply with the NC Building Code, including the Coastal and Flood Plain Construction Standards of the N. C. Building Code, and the Local Flood Damage Prevention Ordinance as required by the National Flood Insurance Program. If any provisions of the building code or a flood damage prevention ordinance are inconsistent with any of the following AEC standards,the more restrictive provision shall control. (10)Pursuant to 15A NCAC, Subchapter 7J.0406(b), this permit may not be assigned, transferred, sold or otherwise disposed of to a third-party. NOTE: All construction must conform to the N.C. Building Code requirements and all other local, State and Federal regulations, applicable local ordinances and FEMA Flood Regulations. SIGNATU X2 DATE: / / 7 PERMITTEE RECEIVED flf''AA IA/II \AI/.1/'TrNAl AIP 1 - i V Locality /y Permit Number 5c/ Ocean Hazard Estuarine Shoreline ORW Shoreline Public Trust Shoreline Other (For official use only) GENERAL INFORMATION . LAND OWNER-MAILING ADDRESS Name_ /,�tl,_._ //(jkDO C _._._____ • Address /0001 .e /LJ/ !/�L,-I Y ,1 — City fd SIM/'140OIN,c) State Al zi,a7sa 6 Phone WI796°.'6 PO i . ,,, Email fJQ11AY-fIRE/104 eCMiL • Co>✓1 UTHORIZF,n AGENT Nakne Address City State Zip Phone Email LOCATION OF PROJECT: (Address,street name and/or directions to site;name oft adjacent waterbody.) !7o63 7 /1 sT S-0R f C 1TY Al c C r cSC- DESCRIPTION OF PROJECT: (List all proposed construction and land disturbance.) s/ 4f v N/L/ fim- / a1 7-iP�i44-e ,gaira/Jvc Na 4kr SIZE OF LOT/PARCEL: square feet o is acres PROPOSED USE: Residential f (Single-family VS Multi-family ❑ ) Commercial/industrial ❑ Other ❑ COMPLETE EITHER(1)OR(2)BELOW(Contact your Local Permit Officer ifyou are not sure which AEC applies to your property): (1) _OCEAN HAZARD AECs:TOTAL FLOOR AREA OF PROPOSED STRUCTURE: square feet(includes air conditioned living space,parking elevated above ground level,non-conditioned space elevated above ground level but excluding non-load-bearing attic space) (2) COASTAL SHORELINE AECs: SIZE OF BUILDING FOOTPRINT AND OTHER IMPERVIOUS OR BUILT UPON SURFACES/ square feet(includes the area of the foundation of all buildings,driveways,covered decks, concrete or masonry patios,etc,that are within the applicable AEC.Attach your calculations with the project drawing.) STATE STORM WATER MANAGEMENT PERMIT: Is the project located in an area subject to a State Stormwater Management Permit issued by the NC Division of Energy, Mineral and Land Resources(DEEMLR)? YES_____ NO _ RECEIVED ��q �� pq�[�GTON, NC tl'vnc IICt the tAtal built nnnn area/imnervinus surface Allowed for vour lot or parcel: D`SOit�C'iL'�'t: OTHER PERMITS MAY RE REQUIRED:The activity you are planning may require permits other than the CAMA minor development permit,including,but not limited to;Drinking Water Well,Septic Tank(or other sanitary waste treatment system),Building,Electrical,Plumbing,Heating and Air Conditioning, Insulation and Energy Conservation,NA Certification,Sand Dune,Sediment Control,Subdivision Approval,Mobile Home Park Approval,Highway Connection,and others.Check with your Local Permit Officer for more information. STATEMENT OF OWNERSHIP: I,the undersigned,an applicant for a CAMA minor development permit,being either the owner of property in an AEC or a person authorized to act as an agent for purposes of applying for a CAMA minor development permit,certify that the person listed as landowner on this application has a significant interest in the real property described therein.This interest can be described as:(check one) /an owner or record title,Title is vested in name of /`i/ U , see Deed Book // - 003 page in the Qj/, K cw County Registry of Deeds. an owner by virtue of inheritance.Applicant is an heir to the estate of probate was in __.—_�County. if other interest,such as written contract or lease,explain below or use a separate sheet&attach to this application. NOTIFICATION OF ADJACENT RIPARIAN PROPERTY OWNERS: I furthermore certify that the following persons are owners of properties adjoining this property. I affirm that I have given ACTUAL NOTICE to each of them concerning my intent to develop this property and to apply for a CAMA permit. (Name) (Address) (I) t-,4.�eK Cc/L-'n)ca 'H 704/ 7ms7, S/R'f C>iy)1 (2)LS_ ?A)2 2 `/O/ !4C AV 706S'. 7 ,57 ,5-oef c/TY ` fle (3) ------_- (d) ACKNOWLEDGEMENTS: I,the undersigned,acknowledge that the land owner is aware that the proposed development is planned for an area which may be susceptible to erosion and/or flooding. I acknowledge that the Local Permit Officer has explained to me the particu- lar hazard problems associated with this lot.This explanation was accompanied by recommendations concerning stabiliza- tion and floodproofing techniques. I furthermore certify that I am authorized to grant,and do in fact grant,permission to Division of Coastal Management staff, the Local Permit Officer and their agents o enter on the aforementioned lands in connection with evaluating information related to this permit application. , a/1J 1 / { This the 7 day of/I0 ✓ .,20I Landowner or person authorized to act as his/her agent for purpose of filing a CAMA permit application This application includes:general information(this form), a site drawing as described on the back of this application, the ownership statement, the Ocean Hazard AEC Notice where necessary, a check for$100.00 nwde payable to the locality,and any information as may be provided orally by the applicant. The details of the application as described by these solaces are incorporated without reference in any permit which may be issued. Deviation,[mm these details will constitute a violation of any permit.Any person developing in an AEC without permit is subject to civil, criminal and administrative action. RECEIVED DCM WILMINGTON, NC iMPs CALCULATIONS SETBACK INFORMATION FLOOD INFORMATION PROPOSED HOUSE/PORCH AREA 1605 SO.Ff. — PERNOUS DRIVE AREA------0 S0.Ff. ZONED:MHS SURF C CONCRETE RAMP AREA------269 SO.FT. are) FLOOD ZONE VE TOTAL IMPERIOUS AFTER COMPLETION----2075 SO.FT. FRONT SETBACSETBACK: 5' BASE OARD:FLOO ELEVATION:11.0' o SIDE STTBACK: DIV LOWE HORIZONTAL ZO.O' PR AREA IN TRACT 7717.4 S0.FT. SIDE STREET SETBACK:10' LOWEST HORIZONTAL YEYBEft 11.00' PROPOSED1L OF LE X OF I COVERP65N1O E-6ERACE 40 REAR SETBACK:20' NAVD BB DATUM MAXIMUM ALLOWABLE x OF IYPFIIMOUS COVERAGE--{Ox 6th STREET 6th ST i SIZE 7th ST 4 7th STREET Mg /'' °c s VICINITY MAP NO SCALE i illigi ,.. • • . • CP N28'44.4-6.W 55.46' C-. �. ! Pb RI ` /_ Ii cONC. RAMP': IC.• •': 20'MBL C. OLD SETTLERS BEACH .p� , .-E.." FlS SECT. 4, BLO 38 FlP LOT 24 I. • b I IS11, PG4 <:T=tit'• 08 41 PG 41 " -' ci a. tr, I 0.18 ACRES "r 5 c' r IUMIIIH IIIIIIBIII �7.5 z en 4. ,•....,`• . DE= PORCH -I: J OLD SETTLERS BEACH a _:4 35' OLD SETTLERS BEACH SECT. 4, BLX 38. LOT 23 N" T^ SECT. 4, BLK 38, LOT 25 _ MB 11. PG 4 ;' . MB 11, PG 4 DB 3872, PG 341 7yI DB 3177, PG 186 —PROPOSED •• o ip''-I 3 STORY 8 o •.1 DWELLING '-'"1" EAVE LINE .c:g .'' 35' - DEM EXISTING CRAVEN �. . • 1 m DRIVE TO BE N' e.,.' Will �K;..--1..l; /�;i:: :I.. POST v1,:..:‘,;:i :''' IPROPOSED r'� : i.'7. �•.�; PEAS GRAVEL „0'' 4:•=.ri`= DONE OHEIi 1_ a _ .7tL.' ' ,'1 R/W —.R . , ,+,y.. CET-._, .,- NM FlS — R/W — — F1• S28-45 00 '54.79 I 10 ulm AIJJ ulm _ OF PAVEMENT 12 w I 7th_STREET iFy 8'12'14'E 49.99' FMN 60' PUBLIC RIGHT-OF-WAY I 7063 7th STREET RPM PRELIMINARY PLOT PLAN **FLOOD CERTIFICATION** 30 15 0 30 60 THIS IS TO CERTIFY THAT THIS PROPERTY IS u LOCATED IN FLOOD HAZARD ZONE 'VE 11• PER GRAPHIC SCALE COMMUNITY # 370186 PANEL) 4245K REVISED 11/1/17--ADDED HOUSE PLAN 'I CERTIFY THAT THIS MAP WAS DRAWN UNDER WY AL--AREA UGHT FCM--FOUND CONCRETE MONUMENT h.— ***LEEEND***— SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER CB--DARN F BOX FMN--FOUND MAG NAIL MBL-MINIMUM BUILDING UNE AREAS COMPUTED MY SUPERVISION FROM A DEED RECORDED IN DEED CH—CHIMNEY FIP--FOUND IRON PIPE OHEL--OVERHEAD ELECTRIC UNE BY COORDINATES BOOK 4163 PAGEAL-OR OTHER REFERENCE C/L--CENTERUNE FlS--FOUND IRON STAKE PG--PAGE SMN--SET NAG NAIL SOURCE MAP BOOK 11 - PAGE 4•THAT THE CONC--CONCRETE FPK--FOUND PK NAIL PP--POWER POLE SPK--SET PK NAIL BOUNDARIES NOT SURVEYED ARE INDICATED AS CP--COMPUTED POINT LP--LIGHT POLE R RIGHT OF WAY TP--TELEPHONE PEDESTAL DRAWN FROM INFORMATION IN DB--DEED BOOK MB--MAP BOOK R/W--RIGHT �GEC{LA SD--SATELLITE DISH TF--TRANSFORMER OR OTHER REFERENCE SOU-: ��'/y DkUE--DRAINAGE& UTILITY EASEMENT SIS--SET IRON STAKE WM--WATER METER THAT THE RATIO OF -- • . . ' AI ACCURACY IS 1:10000+ wY��y (`. • ' SURVEY FOR: COO THE REQUIREMENTS Of• -.1 + PRACTICE FOR LAND Q1- .•• N•- '' SUBDMSION: OLD SETTLERS BEACH (21 NCAC56.1600).'pis : /17 . I GAIRY CANADY SURVEYING S - Cr 24 BLOCK' 36 SECTION: 4 ' L L. P.O. BOX: 915 2780 ONSLOW COUNTY STUMP SOUND TOWNSHIP KINSTON HIGHWAY x �� 17 RICHLANDS, NC 28574 �� / oFFTCE(910)324-acts 1 'i„I.� DATE: 7-19-17 Cf`AI F: 1"�30' FB 275 pG 18-19 FAX:(910)324-8430 �1081LE:910 389-B460 GAIRY I. CANADY PLS % ',OIL cADFlLE CONNERPNJL _ DWG 7063 7TH Innirvr(etvOmm�Tl rnm RECEIVED • n A Milt 6A1Ni.-.T.-... ..— ROY COOPER Governor Y. MICHAEL S. REGAN Secretary Coastal Management ENVIRONMENTAL QUALITY BRAXTON DAVIS Director November 27, 2017 Daniel Murdock 1022 E. Ivy Drive Fuquay-Varina, NC 27526 Dear Mr. Murdock: Attached is CAMA Minor Development Permit No. SC 17-18 for work to be done at 7063 7th Street, Surf City,Onslow County. An electronic copy has been sent to the Pender County Inspection Department. To validate this permit, please sign both copies of the permit as indicated for our records. Retain the orange copy for your files and sign both pages of the white copy and return to us within 20 days of receipt, in the enclosed,self-addressed envelope This is not a valid permit until it is signed and returned to our office. Thank you for your prompt attention to this matter. Sincerely, Shaun K. Simpson Permit Support Technician Enclosures Cc:WiRO files PN Inspection Dept. State of North Carolina 1 Environmental Quality I Coastal Management 127 Cardinal Drive Ext.,Wilmington,NC 28405 U.S. Postal Service CERTIFI'p MAIL® RECEIPT u• Domestic MaftOnly U For delivery information,visit our website at www.usps.com rl mot r7 ri A Ct r^ Certified Mail Fee $ -1 Extra Services&Fees(check box,add fee as appropriate) ❑Return Receipt(hardcopy) $ R ❑Return Receipt(electronic) $ Postmark ❑Certified Mail Restricted Delivery $ Here ] ❑Adult Signature Required $ ❑Adult Signature Restricted Delivery$ 7 Postage $ Total Postage and Fees fl Sent To -R 7 Street and Apt.No.,orPdgozNo. City,State,ZIP+4a :errs iea mall service proviaes me Following oenenis: A receipt(this portion of the Certified Mail label). for an electronic return receipt,see a retail A unique identifier for your mailpiece. associate for s' nce.To receive a duplicate Electronic verification of delivery or atteTipted 4 return recejio additional fee,present this delivery. USPSI=postmarked Certified Mail receipt tothe A record of delivery(Including the recipient's retail associate. signature)that is retained by the Postal Service'" -Restricted delivery service,which provides for a specified period. delivery to the addressee specified by name,or to the addressee's authorized agent. nportant Reminders: -Adult signature service,which requires the You may purchase Certified Mail service with signee to be at least 21 years of age(not First-Class Mail,First-Class Package Service®, available at retail). or Priority Mails service. -Adult signature restricted delivery service,which Certified Mall service is not available for requires the signee to be at least 21 years of ag International mail. and provides delivery to the addressee specified Insurance coverage is not available for purchase by name,or to the addressee's authorized agent with Certified Mail service.However,the purchase (not available at retail). of Certified Mall service does not change the •To ensure that your Certified Mail receipt is insurance coverage automatically included with accepted as legal proof of mailing,it should bear a certain Priority Mail items. USPS postmark.If you would like a postmark on For an additional fee,and with a proper this Certified Mail receipt,please present your endorsement on the mailpiece,you may request Certified Mall Item at a Post Office'"for the following services: postmarking.It you don't need a postmark on this -Return receipt service,which provides a record Certified Mall receipt,detach the barcoded portion of delivery(including the recipient's signature). of this label,affix it to the mallplece,apply You can request a hardcopy return receipt or an appropriate postage,and deposit the mailpiece. electronic version.For a hardcopy return receipt, complete PS Form 3811,Domestic Return Receipt;attach PS Form 3811 to your mailpiece; IMPORTANT.Save this receipt for your records. The UPS Store - #4407 1421 E. BROAD STREET FUQUAY VARINA, NC 27526 (919) 557-2050 11/13/17 01:40 PM We are the one stop for all your shipping, postal and business needs. Exchanges & Gift Certificates Available No Refunds II IIIIII IIIIIII II II II IIIII I IIII II III II II II IIIIII►III I!I 001 500026 (022) TO $ 14.85 Certified Mail/R.R. SubTotal $ 14.85 Total $ 14.85 CHASE VISA $ 14.85 ACCOUNT NUMBER * ************6586 Appr Code: 06316D (I) Sale ENTRY METHOD: ChipRead MODE: Issuer AID: A0000000031010 TVR: 0080008000 TSI: F800 AC: AE85EA3DB5ED3754 ARC: 00 f Receipt ID 82008449341650888376 001 Items CSH: OWEN Tran: 6894 Reg: 002 IVIV VII15 3up1JncJ v Nutnu511 r5 rr ruICI IOI7 • Freight services • Faxing, notary'7p4tal szrvi s and more theupsstore.com Copyright©2014 The UPS Store,Inc. M5410_1661014 The UPS Store ups Print & Business Services • Printing & finishing services • Mailbox services • Packing & shipping services • Moving supplies Er packaging materials • Freight services • Faxing, notary, postal services and more theupsstore.com :opyright©2014 The UPS Store,Inc. M5410_1661014 The UPS Store ups print & B,�.si�ess Services Printing 5- finishing services Mailbox services Packing & shipping services Moving supplies & packaging materials Freight services Faxing, notary, postal services and more Receipts for Certified Mail A/aV a e)/-7 (Staple Here) Date /52.4 nlr ..1)2ra ' 'iai Adj cent Property ner a f/��igon1 C aili g�,�CO�s , crpiemt 1V 1 C a - s 9a City,/State,Zip Code Dear Adjacent Property: This letter is to inform you that nllLr frlazwex have applied for a CAMA Minor Property Owner Permit on my property at 7063 7 rb S'T Z Se p\tr e /TipiC,in Pender/Onslow Property Address County. As required by CAMA regulations, I have enclosed a copy of my permit application and project drawing(s)as notification of my proposed project.No action is required from you or you may sign and return the enclosed noQ objection'form./If you have any questions or comments about my proposed project,please contact me at J/? ! ?O 6�"/Q ,or by mail at the address listed below. If you wish to Applicant's Telephone file written comments or objections with the Surf City CAMA Minor Permit Program,you may submit them to: Jason Dail,Field Representative NC Division of Coastal Management Town of Surf City Local Permit Program 127 Cardinal Drive Extension Wilmington, NC 28405 Sincerely, Z) Al/,. 17DcX Property Owner /o(9a 4. /1/y t r y Dt Mailing Address fLQvivf/-- Uietfk),Ate 07502 City,State,Zip Code r<ECEIVED DCM WILMINGTON, Ni ADJACENT RIPARIAN PROPERTY OWNER STATEMENT FOR CAMA MINOR PERMITS I hereby certify that I own property adjacent to 's (Name of Property Owner) property located at Address, Lot, Block,Road,etc.) on , in , N.C. (Waterbody) (Town and/or County) He has described to me as shown in the attached application and project drawing(s),the development he is proposing at that location,and, I have no objections to his proposal. (APPLICATION AND DRAWING OF PROPOSED DEVELOPMENT ATTACHED). Signature Print or Type Name Telephone Number Date RECEIVED DCM WILMINGTON,NC IMPERVIOUS CALCULATIONS PROPOSED HOUSE/PORCH AREA 1806 SD.FT. SETBACK INFORMATION FLOOD INFORMATION - PERVIOUS ERNE AREA--___-0 SO.FT. ZONED:MHS SURF CONCRETE RAMP AREA------269 SO.FT. T CM) FLOOD ZONE YE • TOTAL WPERNOUS AFTER COMPLETION---2075 SO.FT. FRONT SETBACK:15 FRE FLOOD ELEVATION:11.0' o SIDE ST STREET 7A' LOWEST HO:ZO TOTAL AREA IN FTRACTIMP _________7717.4 S0.FT. SIDE SETBA SETBACK::20' 10' LOWEST DATUMHORIZONTAL YEMBER:11.00' C X L OF LE X OF I COVERAGE 2BAS REAR SETBACK:20' NAVD BB DATUM MAXIMUM ALLOWABLE 1G OF IMPERVIOUS COVERAGE--40% 6th STREET 6th ST Q STE 7th ST 4 y 7N STREET CANAL s�'' Ac 4 VICINITY MAP NO SCALE CP N28'44'461W 55.46' Cik . _ — — "" 1 N��-RAMP. � ;+.',' 20'MBL E4 OLD SETTLERS BEACH r•,`, 7 •FlS SECT. 4, BLK 38 F1PUN 24 , ,I I MB 1111, PG 4 O OB 4163, PG 41 :'..,,,,_-;'.1.'4'e%\::,:: I0.18NMES ='{ II1IIliI I I]fllllll t 17.5'z N ..:i '-1 EA 14.0' 21B • ..T>:V`�a DECK PORCH m B.5' OLD SETTLERS BEACH a a:;_t' 35' OLD SETTLERS BEACH SECT. 4 BLK 38, LOT 23 N 1. PIED SECT. 4, BLK 38, LOT MB 11, PG 4 1::' fD MB IT, PG 4 DB 3872, PG 341 o?4, DB 3177, PG 186 • PROPOSED PZ o %;;77 DWELLING o •t<`i EAVE UNE c:4' 35' 6.5' • COSTING GRAVELSE �; :-,4--: ,.,; REPIAcORM m ISM y r;�',. ,. • POST PERVIOUS GRAVEL '� LY'� ;• r %.� f PROPOSED ADOMONAL 1: PEIWOU0 GRAVE *1 ./'`...•• TL ,i;•:i DRIVE • • OHEL — — . •,FIS •':ti.'. ▪ ..J -, *0 F1S R/WR/W — �— - _ •I S28.45 00 '64.79' PH (U. lv p _• F 41m E OF PAVEMENT I 7th_STREET 4 FMN S28'12'14'E 49.99' �FMN 60' PUBLIC RIGHT-OF-WAY — 7063 7th STREET R/W PRELIMINARY PLOT PLAN **FLOOD CERTIFICATION** 30 15 0 30 60 THIS IS TO CERTIFY THAT THIS PROPERTY IS 11/11/111 LOCATED IN FLOOD HAZARD ZONE YE 11• PER GRAPHIC SCALE COMMUNITY # 370186 PANEL] 4245K REVISED 11/1/17--ADDED HOUSE PLAN I CERTIFY THAT THIS MAP WAS DRAWN UNDER MY AL--AREA UGH!' FCM--FOUND CONCRETE MONUMENT �— ***LEECEND***— SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER CB--CABLE BOX FMN--FOUND TAG NAIL MBL-MINIMUM BUILDING UNE (AREAS COMPUTED MY SUPERVISION FROM A DEED RECORDED IN DEED CH--CHIMNEY FP--ROUNDIRON PIPE OHEL--OVERHEAD ELECTRIC UNE BY COORDINATES BOOK 4163 PAGE 41 OR OTHER REFERENCE C/L--CENTERUNE FlS--FOUND IRON STAKE PG--PAGE SMN--SET MAG NAIL FPK--FOUND PK NAIL MAP BOOK 11 PAGE 4•THAT THE CONC--CONCRETE PP--POWER POLE SP-- SET NAIL BOUNDARIES NOT SURVEYED ARE INDICATED AS CP--COMPUTED POINT �--LIGHT Pax R/W--RIGHT OF WAY TP -TELEPHONE PEDESTAL DRAWN FROM INFORMATION IN DB--DEED BOOK MB--MAP BOOK Et4LA SD--SATELLITE DISH IT--TRANSFORMER OR OTHER REFERENCE SOU., �p�4 D&UE--DRAINAGE& UTILITY EASEMENT SIS--SET IRON SINCE MA--WATER MtItH THAT THE RATIO OF -• • I• V ACCURACY LS 1:10000+ 1'".4_101 - • - SURVEY FOR: COO THE REQUIREMENTS OFF�H rd,, -. . PRACTICE FOR LAND�' N•- 7 SUBDMSION: OLD SETTLERS BEACH (21 NCAC58.1600)..Z 115 ilia 17 . GAIRY' SEAL, -OT #• 24 BLOCK. 38 SECTION:, 4 COY SURVEYING ��V7 P.O. BOX: 915 2780 ONSLOW COUNTY STUMP SOUND TOWNSHIP KINSTON HIGHWAY �1 y`? 17 RICHLANDS, NC 28574 .AA. X �� / OFFICE(910)324-4616 .{1..� DATE: 7-19-17 SCdI F. 1'�30' FB 275 PG 18-19 FAX:(910)324-8430 RECEIVED �MoBILE 910 389-8460 GNRr I. CANARY PLS 0� a CADFlLE CONNERPAUL DWG 7063 7TH Ieafrvre(HVtDamearnm nr.il WILMINGTON, NC U. . Posta ervice CERTIFIED MAIL° RECEIPT n Domestic Mail Only U For delivery information,visit our website at www.usps.com' ✓ Certified Mail Fee g Extra Services&Fees(check box,add fee as appropriate) ❑Return Receipt(hardcopy) $ ❑Return Receipt(electronic) $ Postmark ❑Certified Mail Restricted Delivery $ Here Adult Signature Required J DI $ 0 Adult Signature Restricted Delivery$ RECEtVEL Postage DCM WILMINGTON, NC Total Postage and Fees r, $ NOV 14 201? 13 Sent To 8 3 Street and Apt.No.,or PO Box No. City,State,ziP+da 'Cr Nr ICu IYidrr.ICI VIUW FA WYruWO ucr rcr rw. A receipt(this portion of the Certified Mail label). for an electronic return receipt,see a retail A unique identifier for your mailpiece. gssociate for assistance.To receive a duplicate Electronic verification of delivery or attempted return receipt foi4;n'1igditionarfee,present this delivery. LISPS®-postmarked Certified Mail receipt to Mr A record of delivery(including the recipients retail associate. signature)that is retained by the Postal Service— -Restricted delivery service,which provides for a specified period. delivery to the addressee specified by name,or to the addressee's authorized agent. mportant Reminders: -Adult signature service,which requires the 1 You may purchase Certified Mail service with signee to beat least 21 years of age(not First-Class Mail°,First-Class Package Service°, available at retail). or Priority Mar service. -Adult signature restricted delivery service,whicl I Certified Mail service is not available for requires the signee to be at least 21 years of ag International mall. and provides delivery to the addressee specifier I Insurance coverage is not available for purchase by name,or to the addressee's authorized agen with Certified Mail service.However,the purchase (not available at retail). of Certified Mail service does not change the •To ensure that your Certified Mail receipt Is insurance coverage automatically included with accepted as legal proof of mailing,it should bear certain Priority Mail items. USPS postmark.If you would like a postmark on I For an additional fee,and with a proper this Certified Mail receipt,please present your endorsement on the mailpiece,you may request Certified Mail Item at a Post Office'"for the following services: postmarking.If you don't need a postmark on this -Return receipt service,which provides a record Certified Mail receipt,detach the barcoded portior of delivery(Including the recipient's signature). of this label,affix it to the mailpiece,apply You can request a hardcopy return receipt or an appropriate postage,and deposit the mailpiece. electronic version.For a hardcopy return receipt, complete PS Form 3811,Domestic Return Receipt.attach PS Form 3811 to your mailpiece; IMPORTANT.Save this receipt for your records. The UPS Store - #4407 1421 E. BROAD STREET FUQUAY VARINA, NC 27526 (919) 557-2050 11/13/17 01:43 PM We are the one stop for all your shipping, postal and business needs. Exchanges & Gift Certificates Available No Refunds II IIiIII II III II II II II II I IIIIiII IIII II II IIIIIIIII 111111 001 500026 (022) ( $ 14,n Certified Mail/R.R. SubTotal $ 14.85 Total $ 14.85 CHASE VISA $ 14.85 ACCOUNT NUMBER * ************6586 Appr Code: 022560 (I) Sale ENTRY METHOD: ChipRead MODE: Issuer AID: A0000000031010 TVR: 0080008000 TSI: F800 AC: 9FE3AAD0C10675F1 ARC: 00 f71 Receipt ID 82008449341657888375 001 Items f'CLI. nwrm r...,r. cant: o,. .. nnn Services_ • Printing & finishing services • Mailbox services • Packing Er shipping services • Moving supplies & packaging materials • Freight services • Faxing, notary, postal services and more theupsstore.com Copyright©2014 The UPS Store,Inc. MS410_1661014 The UPS Store ?rht & Bustcss Services • Printing & finishing services • Mailbox services • Packing 5r shipping services • Moving supplies & packaging materials • Freight services • Faxing, notary, postal services and more theupsstore.com Copyright©2014 The UPS Store,Inc. MS410_1661014 The UPS Store ups print & Business Services i ,1 i 4 • Receipts for Certified Mail (Staple Here) 9. piOli a,o/7 Date �/rccfK CA Alit)/0wG/I Adjacent PropertxOwner, 808 c�o it i, LII/ Mj/eKnN.1)s / Ale o?VSII/ City, State,Zip Code Dear Adjacent Property: This letter is to inform you that I, .0/9 iti/LA, YuRD�e>L have applied for a CAMA Minor 7063 Prop�rty Owner Permit on my property at 7 TT s T. Su Rc' c/tY , 1VC ,in Pender/Onslow Property Address County. As required by CAMA regulations,I have enclosed a copy of my permit application and project drawing(s)as notification of my proposed project.No action is required from you or you may sign and return the enclosed no objection form. If you have any questions or comments about my proposed project,please contact me at 9i 79.5'. ro 9y6) ,or by mail at the address listed below. If you wish to Applicant's Telephone file written comments or objections with the Surf City CAMA Minor Permit Program,you may submit them to: Jason Dail,Field Representative NC Division of Coastal Management Town of Surf City Local Permit Program 127 Cardinal Drive Extension Wilmington,NC 28405 Sincerely, 1YuZiX'CY 1 Qf'V1kL Property Owner I c 2a L;. /I/,✓ j%i i AV .1 ailing Address v Q tl,oy. VAC?i' ►M ) , jC a 75 L4 City,State,Zip Code RECEIVED DCM WILMINGTON,NC .in%, 1 :j n(141 ♦ ADJACENT RIPARIAN PROPERTY OWNER STATEMENT FOR CAMA MINOR PERMITS I hereby certify that I own property adjacent to 's (Name of Property Owner) property located at Address, Lot, Block, Road, etc.) on , in , N.C. (Waterbody) (Town and/or County) He has described to me as shown in the attached application and project drawing(s), the development he is proposing at that location, and, I have no objections to his proposal. (APPLICATION AND DRAWING OF PROPOSED DEVELOPMENT ATTACHED) Signature Print or Type Name Telephone Number Date RECEIVED DCM WILMINGTON, NC t IMPERVIOUS CALCULATIONS PROPOSED HOUSE/PORCH AREA 1806 SO.F7. SETBACK INFORMATION FLOOD INFORMATION PERVIOUS DRIVE AREA 0 SO.FT. ZONED:MHO(SURF CRY) FLOOD ZONE VE CONCRETE RAMP AREA 269 5Q.FT. FRONT SETBACK:15' BASE FLOOD ELEVATION:11.0' TOTAL IMPERVIOUS AFTER COMPLETION----2075 50.FT. SIDE SETBACK:7.5' FREEBOARD:+0.0' TOTAL AREA IN TRACT 7717.4 SQ.F7. SIDE STREET SETBACK:10' LOWEST HORIZONTAL MEMBER:11.00' 2 PROPOSED X OF IMPERVIOUS COVERAGE 26.8% REAR SETBACK:20' NAVD 88 DATUM MAXIMUM ALLOWABLE X OF IMPERVIOUS COVERAGE--40X 6th STREET 6th ST SITE 7h ST 4 4 7th STREET Me 7'' pc4 VICINITY MAP NO SCALE CP �N28'4�4'46'W�95.46' C _ CONC:RAMP+A.':'''i 20'MBL7-12r, u OLD SETTLERS BEACH F. .. •FIS SECT. 4, BLK 38 LOT 24 FHP ,I o I 1AB 11. PG 4 4 DB 153. PG 41 1::::,,g 0 I 0.18 ACRES .. I 'L..,.' 7.5'z m '1 0, •4�1::: 14.0' 21.0' 0. CA Y ', ::-::.10 DECK PORCH •B.5 OLD SETTLERS BEACHc.; ':''k u' -•-. OLD SETTLERS BEACH SECT. 4. 6LX 3M LOT 23 N ,t N m SECT. 4 Bx 38 LOT 25 MB 11, PG 4 '":� m MB 11, PG 4 DB 3872, PG 341 P DB 3177, PG 186 ''�T PROPOSED o 'go .p;'::J n 3 STORY a Q. DWELLING .!'.; EAVE LINE `It,' u' ��8.5' ;!-:'..m DECK PORCH o cep1 a l Damp GRAVEL 10, m 14.0' m 105'• DRIVE TO BEREPLACED WITH ',' `,t .e3yv..: :.,.. .y:..: co POST PERVIOUS GRAVEL I . .r`'R • fPADOTTPOA AL -.,, .. PERVIOUS GRAVEL +-':, YV DRIVE CA. OHEL FIS .•P,_i` .,,.,t "` • `.,ivvM TFIS RCN R W — ——` PH•: S28'45 005 54.79 I — i m I0 WIC PI`i 1. E OF PAVEMENT — —--- -IC. ` � 7th_STREET IFUN 528'12'14"E 49.99' FUN 60' PUBLIC RIGHT-OF-WAY I 7063 7th STREET R/W PRELIMINARY PLOT PLAN **FLOOD CERTIFICATION** 30 15 0 30 60 THIS IS TO CERTIFY THAT THIS PROPERTY IS II LOCATED IN FLOOD HAZARD ZONE 'VE 11' PER COMMUNITY # 370186 PANEL# 4245K GRAPHIC SCALE REVISED 11/1/17--ADDED HOUSE PLAN 9 CERTIFY THAT THIS IMP WAS DRAWN UNDER MY AL--AREA LIGHT FCM--FOUND CONCRETE MONUMENT t— ***LGEND***— SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER CB--ALE BOX FMN--FOUND HAG NAIL MBL-MINIMUM BUILDING LINE AREAS COMPUTED MY SUPERVISION FROM A DEED RECORDED IN DEED CH--CHIMNEY HP--FOUND IRON PIPE OHEL--OVERHEAD ELECTRIC UNE BY COORDINATES BOOK 4163 PAGE_4_1_OR OTHER REFERENCE C/L--CENTERUNE AS--FOUND IRON STAKE PG--PAGE SUN--SET MAG NAIL SOURCE MAP BOOK 11 - PAGE Th8T THE CONC--CONCRETE FPK--FOUND PK NAIL PP--POWER POLE SPK--SEE PK NAIL BOUNDARIES NOT SURVEYED ARE INDICATED AS CP--COMPUTED POINT LP--UGHT POLE R/W--RIGHT OF WAY TP--TELEPHONE PEDESTAL DRAWN FROM INFORMATION IN �ppGFN/A DB--DEED BOOK MB--MAP BOOK SD--SATELLITE DISH TF--TRANSFORMER Q / D&UE--DRAINAGE & UTILITY EASEMENT WM--WATER METER OR OTHER REFERENCE SOUR(t' :. � •�4� SIS--SET IRON STAKE THAT THE RATIO OF PR T ACCURACY IS 1:10000+ �,'1 ( ♦. SURVEY FOR: CDD THE REQUIREMENTS O .1,(T .J'NN PRACTICE FOR LAND Q)' *(7 NO- •�T SUBDIVISION: OLD SETTLERS BEACH (21 NCAC56.1600).' -ITS iL. 17 . GAIRY CANARY SURVEYING SEAL.r. OT #: 24 BLOCK' 38 SECTION: 4 :_ �- P.O. BOX: 915 2780 L-2904 TOWNSHIP KINSTON HIGHWAY .A. �' ONSLOW COUNTY STUMP SOUND 1 �.• 17 RICHLANDS, NC 28574 iA �� / tEC 1DATE: 7-19-17 SCALE: 1-30' FB 275 pGto-19/NC A 111111 •mi....,-,,,a a National Flood insurance Program V-Zone Certification Property Information For Insurance Company Use Name of Structure Owner Policy Number DANIEL MURDOCK Structure Address or Other Description 7063 7TH ST. City State Zip Code SURF CITY NC 28460 SECTION I: FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Note: to be obtained from appropriate FIRMs 1. Community Number 2. Panel Number 3. Suffix 4. Date of FIRM Index 5. FIRM Zone SURF CITY- 370186 3720424500 J 02/16/07 Vi i SECTION II: ELEVATION INFORMATION Note: This form is not a substitute for an Elevation Certificate, Elevations should be rounded to nearest tenth of a foot. 1. Elevation of the Bottom of Lowest Horizontal Structure Member 13.0 feet 2. Base Flood Elevation 11.0 feet 3. Elevation of Lowest Adjacent Grade 3.0 feet 4. Approximate Depth of Anticipated Scour/Erosion Used for Foundation Design 4.0 feet 5. Embedment Depth of Pilings or Foundation Below Lowest Adjacent Grade ............................ 12.0 feet 6. Datum Used: NGVD '29 X NAVD '88 Other SECTION III: FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Note: This section must be certified by a registered professional engineer or architect I certify that I have developed or reviewed the structural design, plans and specifications for construction and that the methods of construction to be used are in accordance with accepted standards of practice for meeting the following provisions: a) The bottom of the lowest horizontal structure member of the lowest floor (excluding the pilings or columns) is elevated to or above the BFE; and, b) The pile or column foundation and structure attached thereto is anchored to resist flotation, collapse and lateral movement due to the effects of the wind and water loads acting simultaneously on all building components. Water loading values used are those associated with the base flood including wave action. Wind loading values used are those required by the applicable State or local building code. The potential for scour and erosion at the foundation has been anticipated for conditions associated with the flood, including wave action. SECTION IV: FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Note: This section must be certified by a registered professional engineer or architect I certify that I have developed or reviewed the structural design, plans and specifications for construction and that the design and methods of construction to be used for the breakaway walls are in accordance with accepted standards of practice for meeting the following provisions: a) Breakaway collapse shall result from water load less than that which would occur during the base flood; and, b) The elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the effects of wind and water loads acting simultaneously on all building components (wind and water loading values defined in Section III). SECTION V; CERTIFICATION (Check: Section iii X and/or Section IV X ) Name of Certifier Title FOUNTAIN TAYLOR III, P.E. PROFESSIONAL ENGINEER Firm Name License Number FOUNTAIN TAYLOR III, P.E. , 17699 LA., Street Address1 '%. Phone Number 2135 KINSTON HWY. ' �,, ,� �''- ' ( 910) 358-0648 City ,Q SEAL '-% = State Zip Code RICHLAND 17691-4.; NC 28574 RECEIVED DCA,WILMINGTON. NO C 2 2 >g P51000C 506Ws 0 g MURDOCK RESIDENCE wCr>' 7063 7TH ST. SURF CITY,NC 2 SHEET INDEX: (.) TITLE SHEET PG.I-FRONT&LEFT ELEVATIONS PG.R-REAR&RIGHT ELEVATIONS PG.3-GROUND&FIRST FLOORPLAN PG.4-SECOND&THIRD FLOORPIAN PG.6-S PILE SECOND THIRD FRAMINGFRAMING PLANS MURDOCK RESIDENCE PG.6-SECOND R:THIRD FLOOR FRAMING PLANS PG.7-THIRD FLOOR ROOF SUPPORT PLAN 7&]HEAl4'D SQ.Fr. PG.8-DETAILS&NOTES /� 1 I lEl J 1_ lIer • • amaaaRfwrna. _ . _. __. __ __ • • ■■ .S .0 b i .� I pp! pp 1 i SS tfri 1/4\ op, : i • 6• .. _ IN WHERE BRICK OVERHANG.SE OVERHANG '� • WHERE BUCK VENEER IS USED.VERIFY BRICK• anaa9aml._'nsAlao] amrtamRnBe LOCATIONS WITH CONTRACTOR PRIOR TO TRUSS :..._............._...._..... .ofu.............._... "'.................... .... CONSTRUCTION _ _ Mal ROOF PLAN LIGHT'LOCATION OF PACE WITH CONTRACTOR /� \\ �� - " � - LIGHT ATM STORAGE SPACE WII4I CONTRA(TOA / PRIOR TO TRUSS CONSTRUCTION. /�\ - _ /�I� _ SCALE; 6"=1'-0" CATHEDRAL CEILINGS,VAULTED CEILINGS — - /A /////,II II`\\ AND/OR CERDIGDUNS AS NOTED ONPIOOR - _ _ 1 / - c` I 'I /777 ` I _ PLAN. _ — - \V _ _ �// �V IT LS THE SOLE RES➢ONSIBIISIY OF THE CONTRACTOR AND/OR BUDDER TO CONI[IRM TO Au STANDARDS,PROVISIONS, FRONT ELEVATION ITv V REQUIREMENTS,METHODS OF CONSTRUCTION AND USES OF MATBRIAIS PROVIDED IN BUILDINGS AND/OR STRUCTURES AS REQUIRED BY NC UNIFORM BUILDING CODE,LOCAL AGENCIES AND DI ACCORDANCE WITH GOOD ENGINEERING PRACTICES. NEITHER CONNER DRAPING6:DESIGN NOR ANY OP ITS SUB-CONTRACTORS ARE RESPONSIBLE PORANY PROBLEMS DUE TO CONNER DRAFTING do DESIGD 1M N.WILAIINGTON ST. HUMAN ERROR AND/OR OMISSIONS ON TERSE DOCUMENTS.IT IS THE OWNER AND/OR CONTRACORS RESPONSIBILITY TO TE R0CHANDS,NC M4 CAREFULLY REVIEWTHESE PLANS FOR ERRORS AND OMISSIONS PRIOR O CONSTRUCTION.IP PROBLEMS AREPOUNDE THE 9103242879 P A REVIEW PLEASE NOTIFY CONNER DRAPING AND DESIGN PRIOR TO BEGINNING CONSTRUCTION SO ANY REVISIONS CAN BE MADE ®AD CONNBIvpAPTINGWA HNO COY G LUF >C. i Li U !U, L� a U —I_I—I • n — ■■ ?1L ' _ _■■ ■■_—_ I I- 1 - - . -- �" \\ D II aIIII'I!I'I'11111111 IIIIIIilllllllllllllll NMI _ _ col - _ - uullllllllllllllllllll AIR ill II II •1 - ICII i ME ME _: MN MN MN EM FRONT ELFVATION s�j=1,-0• IDIIDI ME NE — ii NE iI�,;I,,,, OHM UN - I IIII IIIIIIIIIIIIIIII II111I III _/ - --- - III IIIIIIIIIII LEFT FT.FVATION SCALE:}•=I,_0• •TISTHE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR BUILDER TO CONFORM TO ALL STANDARDS,PROVISIONS, e_ NOTICE FRONT&LEFT ELEVATIONS REQUIREMENTS,METHODS OF CONSTRUCTION AND USES OP MATERIALS PROVIDED IN BUILDINGS AND/OR STRUCTURES AS APPLIES ONLYRAM MIIRDOCK G D D REQUIRED BY N.C.UNIFORM BUDDING CODE,LOCAL AGENCIES AND IN ACCORDANCE WITH GOOD ENGINEERING PRACTICES. ,,,,-,ER sTR,Wpcp1FD sans AN USE IS PIOEE�DOYD. RESIDENCE NEITHER CONNER DRAFTING.DESIGN NOR ANY OF PIS SUBCONTRACTORS ARE RESPONSIBLE POR ANY PROBLEMS DUE TO NO MILT IS TO eem •^''•^eno,71'i0•n•"r'' MOOW=REDRAWN OR USED HUMAN ERROR AND/OR OMISSIONS ON THESE DOCUMENTS.IT IS THE OWNER AND/OR CONTRACTORS RESPONSIBILITY TO0711.1111.SSNoNWSLREARIN. MURDOCK RESIDENCE 1utq Bam CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS PRIOR TO CONSTRUCTION.IF ANY PROBLEMS ARE POUND IN THE BRA SUIP NC REVIEW PLEASE NOTIFY CONNER DRAFTING AND DESIGN PRIOR TO BEGINNING CONSTRUCTION SO ANY REVISIONS CAN BE MADE �� �' ...... umm•DTERE COPYRIGHT I M .NTrc I ` C]BII TDD tOONSmplEDBEw:...USAGE w rE nxx U Z Z p0 IA>Z W_ U2 W_J It - F U = Cl _ 1 Eli di \ \\\ = I IIIIIIIIIII Inumunil inn nn= =nn L II II HI II I I I II I IL I II _- ih & - :_ Eli , I I_ HL R I JIJ -- I�r NJ- IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII - !IlIIIIII_ _ __! ' ::: IIIIIIIIIIIIIIIIIIIIIIIIII . l: = ■■ ■■ -■■■■ ■■_-- - - u■ REARF.i.FVATION �I�I�� �� ��-IIIII MN �� �� NM NM SCALE:r=r-o^ - _. - I IIpl1IIIIIillllp IIIII�IIIIIII' III I I IIIIIIIIIIIIDIIIIIIII _ IIIIIIIIIIII IIIOI�I _ - - RIGHT ELEVATION SCALE I"=r-o^ IT IS THE SOLE RESPONSIBILITY OP THE CONDUCTOR AND/OR BUILDER TO CONFORM TO ALL STANDARDS,PROVISIONS, ' NOTICE V REAR&RIGHT ELEVATIONS REQUIREMENTS,METHODS OP CONSTRUCTION AND USES OP MATERIALS PROVIDED IN BUILDINGS AND/OR STRUCTURES AS THIS DRAWING APPLIES OI.B,V MURDocK D D REQUIRED BYN.0 UNIFORM BUILDING CODE,LOCAL AGENCIES AND IN ACCORDANCE WIN GOOD ENGINEERING PRACTICES TO TOO yTe SPELV'IEO NBRS¢.,ANY OTA NEITHER CONNER DRAFTING&DESIGN NOR ANY OP ITS SUBCONTRACTORS ARE RESPONSIBLE POE ANY PROBLEMS DUE TO PART TO BEOPID. RESIDENCE s/...M nrw,wc•wwa., ED.PEDEN.011 USED TA PS ill HUMAN ERROR AND/OR OMISSIONS ON THESE DOCUMENTS.IT IS THE OWNER AND/OR CONTRACTORS RESPONSIBILITY TO O HER1P THAN BVDKni DHERem. MURDOCKRESIDENCR uILDESIC) CAREFULLY REVIEW THESE PLANS POR ERRORS AND OMISSIONS PRIOR TO CONSTRICTION.DF ANY PROBLEMS ARE POUND IN THE ANY VIOLATIONWILL BE REVIEW PLEASE NOTIFY CONNER DRAFTING AND DESIGN PRIOR TO BEGINNING CONSTRUCTION SO ANY REVISIONS CAN BE MADE �' R-+F^^ �INFRINGEISEINT AND IS `� ` OAI7 OD CONSIDERED II”,.USAG A IR I A,,,,,,,,,,, �� �IPRJaNw�nxR U Z Z Q0 >Z w_ U� f L 1T FT n TT TTT1-.----IT FT FT 1T TT 1-1 TT 11111 iiiiiiiiiiiin iiiiiiiiiiiiii i!{C7!`T!` T!` 7!` F-_e U :: 11I COVERED DECK \p9§ 34-0':Br :i mm � mm 11..' 7-P 3'-0' Ste' 17-1: II'-R' f - IIr f -114. i ,r—f-5'-6' 7-9 Tr P4 •-IV--f—s-0' Iii - N N �.1mYAvoR16cl1sRlL p 11 O'le- m =•'q BEDROOM .,:£r, BATH '" a BEDROOM I S. A 11�0'a 13'fi' 12J'z 172M A T. b ^T h r I! tr 1 9'fi' 294 ~ - • M -- 1 N r J ,— / f ., fNEMO w M.�. :, fi r ' B'.50' EN 21 Bo:S'A a �� as . BATH L_ T HEVATOI § IILEVA'IOR ! O /oARBPoO'lA4e �� a`rf-5`x' 4�� ram: T J R caolmm nnoc • MATED ���� l. ?,, b \ b ��� Rt S^ Pux*nnoR�_-._.___ ; IS-10' 4.-6'—A#-3'-1B• 1 Si• B'6• —1 I,. IEEE ii El .. CLOSET ¢' • IIPAYeD--.-_-- b .. BEDROOM I . BEDROOM _ 'q§ . l3'1'a ITT. N F 17-ai11'fi11'fi' FRAMING I.EGSND b SL n ! srO I..RAD IXWAu r . r - >U I.PLY, I I O k ur(w BRACE I 9. I 1 . I V _ r A RABn c POMP 11'A' 11W' .1' 11'r 1 .r—l—s-10'' s-1' r-IB'—l—sr I BLIP 1 1 I7-t0' 3S-0' 13'-10` I A.•DIMENSIONS ARE FROM i • L b m COVERED DECK FACE OF EXTEIUOR WALLS AI, I-INE OF INTERIOR WALLS.AL ' 35'd'asr DOOR AND WINDOWS ARE LC THEIR APPROXIMATE CENTEL AND WINDOW SIZES ARE LAB \ ..._.I�.—., .....—1�. ___ __ _. !7 - __ ..................® ♦ '_tee -: -• THEIR NOMINAL SIZE VERIFY I I _E' ' I DIMENSIONS AND CONTACT( N : —— ssr- X SS': DRAFTING&DESIGN OF ANY -,-—I' DISCREPANCIES PRIOR TO CO 4 --Z' �®e.z A".v"u�nvrnv - \ TYPICAL CEILING HEIGHT OP -.;! GROUND FLOORPLAN FLOORUNLESS �a = scn111=1:"=1' FIRST FLOORPLAN CATHEDRAL CEILINGS,VAULT __ SCAT-E.-."=r-O' AND/OR GEEING DUNS AS MOOR PLAN. iJ'"'_ ^'k.: / CONTRACTOR TO VERIYTI/ /� MELT EMERGENCY ESCAPEA �'a_ ——. OPENING REQUIREMENTS IN SLEEPING ROOM AND TIGHT/VENIIATIDN REQUD (UO3)IN EACH HABITABLE RC f No se- IT IS THE SOLE RESPONSIBILITY OF THE CONTRAll.AND/OR BUILDER TO CONFORM TO A STANDARDS,PROVISIONS, NOTICE GROUND&FIRST FLOORPLAN /) REQUIREMENTS,METHODS OF CONSTRUCTION AND USES OF MATERIALS PROVIDED IN BUILDINGS AND/OR STRUCTURES AS E RA3vDIG APPLIES DI:B.YPIALA DLURDOC:K G V V REQUIRED BY N.C.UNIFORM BUILDING CODE,LOCAL AGENCIES AND IN ACCORDANCE WITH GOOD ENGINEERING PRACTICES. THE Orbs DECODED HEREIN. ANY OMER NEITHER CONNER DRAFTING&DESIGN NOR ANY OF ITS SUB-CONTRACTORS ARE RESPONSIBLE FOR ANY PROBLEMS DUE TO NO PART IS DI BE COI RESIDENCE COPIED, mors•ADA : ERm>rw;Ren .�R USED HUMAN ERROR AND/OR PLANS ON THESE DOCUMENTS.OMISSIONS IT IS TTiRTI) AND/OR CONTRACTORS ASIBILIY TO MUHDOIX RESID@iCE zoiaYOY•Il CAREFULLY REVIEW THESE PLANS POE ERRORS AND OMISSIONS PRIOR TO CONSTRUCTION.IF ANY PROBLEMS ARE POUND IN THE ENE TM BEA 'ET MCYd11 " NC REVIEW PLEASE NOTIFY CONNER DRAFTING AND DESIGN PRIOR TO BEGINNING CONSTRUCTION SO ANY REVISIONS CAN BE MADE DIRECT R �_�6A � SOO�,' R'.^. '(' 'uEE®'A ` OMDCOD tRnh�EREDIIIPrAIusA A a,u,lsu'a. v.... .N.Y ®Para""` :,,v z p0 >C9 lil z. • U 2 W J 0 a ftsr 1SINGLE-RV nnUBLxPLY wow•rnu.s•sanc•Tron• i b b COVEREDD DECK DECK 16'-0iRrr JS-0'aBr '® wnurmo. ®®um aoc 34r TO mums u,T lr-0• ..Y�... r-0•— 11•-D• I to.r c.o. ./• 6•-0•—f—rr -Liv/ . �m .�,R�,. a.� " NiBnomcataxe•rµ` 'A1L �amw000nnmr ••� • nrrxw.w.auu.uu Y PROM LIVING DINING 4 R BOON Iq SDTNGROOM/ Be N i§ ROOM a 13'-A' 17�i 13S t' IDOKOUI'tOW6R Repg ` 41 ^e, ` 05i 4 :� A "s ` CONTRACTOR TO VERIFY ALL LOCI' y.. Pam`o.,.a =fi Itl, ,r, 7.i .L''': " WE RE TEMPERED GLASS WINDOW .1 -:-. ' 4 ♦y I CHILD SAFETY LOCKS MAY BE REQL m Jr— OO.e 7y EEO. { INNEN�1 IQI'Cf�i b -r_ zs'-Y..tow' THIRD FLOORPLAN AN "SQUAW ACE r R • GROUND FLOOR '§` EisvAI•OR -a• -to• re•� SCALE=Y'=1•-0' • ._ mom 5'ra5r I �Y I_� �_-,I t },k • —y �''I�• f Y LAUNDRY • • MATED ..• eoP U MEI 't} MED 11.10D FLOOR +'t11 f 6T-0�. fi' MOND MOOR • RIV. b b 'Or-10 I I b t•-I' MASTER neat__.. ._J S Id' �� _`I ri BEDROOM ��— • TEAMING LEGEND Iy1' • } IT-0•a IS'-• • ,WALL ' BATH GI.RI t+ a fN.CLOSET m m_ 6rl i�nP1 `I. .Fi1�I 6'ra 1 • \\\ B-loitBV f b }R ..........._......................_........___....._..............._..__.........._.._ Ri.ow vn. 111 !.l I. R.nI,:c; Ste• 15-2• f.i Lf a a.or R'Pni.? I Raual�x9 'I.___.m i.nnr '.ISO Li I •. 1-{'r—A—V-V 1 12•—M—S'r 5'-0•—N----6'-0•�1-2,64—rr . A A'fi'� ALL OF ARE PRONG PACE OF EXTERIOR WAILS AN IOWEllIOE•—* LINE OP INTERIOR WAILS.ALL • b I COVERED DECKDOOR AND WINDOWS IA a THEIR APPROXIMATE CENTER : AND WINDOW SIZES ARE IRBI amm • o THEIR NOMINAL SIZE VERIFY _. ....._.... je ta4B'' I' ....._ _.._. _......._• DIMENSIONS ROTO CONTACT! rT FT r * • ..Ehi TYPICAL CEDING HEIGHT OP' FIRST FLOOR AND 8.-0.ON ADI A IS -0•A' M.O. / FLOORS UNLESS OTHERWISEF A M.O. I CATHEDRAL CEILINGS,VAULT AND/OR CEILING TREYS AS NI SECOND FLOORPLAN FLOOR PLAN. SCALE=Y."=I•-0" CONTRACTOR TO VERIFY DIA MEET EMERGENCY ESCAPE AI OPENING RPQUItEMBIDS IN I SLEEPING ROOM AND UGHT/VFNTIATION REQUIR (R303)IN EACH HABITABLE RO Nill IT ISTHE SOLE RESPONSIBILITY OF THE CONRACIOR AND/OR BUILDER TO CONFORM TO ALL STANDARDS,PROVISIONS, r NOTICE v SECOND&THIRD FLOORPLAN REQUIREMENTS,METHODS OP CONSTRUCTION AND USES OP MATERIALS PROVIDED IN BUILDINGS AND/OR STRUCTURES AS lTHISDRAWING 3PIESONLYN nett )\�IIRDOCK D D REQUIRED BY N.C.UNIFORM BUILDING CODE,LOCALAGENCTES AND IN ACCORDANCE WITH GOOD ENGINEERING PRACTICES. ANY USR RESIDENCE NEITHER CONNER DRAFTING&DESIGN NOR ANY OP ITS SUBCONTRACTORS ARE RESPONSIBLE POR ANY PROBLEMS DUE TO NO TB'O IS COKED m. 4 HUMAN ERROR AND/OR OMISSIONS ON THESE DOCIflHUIIS.IT IS THE OWNER AND/OR CONTRACTORS RESPONSIBILITYTO Oit�tTWV INDIUM w. MURDOCIC RESIDENCE .x OR USED NFm,ic m.. `I CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS PRIOR TO CONSTRUCTION.IP ANY PROBLEMS ARE POUND IN THE >M " "6"•'" "5 NC REVIEW PLEASE NOTIFY CONNER DRAFTING AND DESIGN PRIOR TO BEGINNING CONSTRUCTION SO ANY REVISIONS CAN BE MADE � SURP�' N«PP`"I,DIAPPLYGI "1OOm"w ` •RIBD CCO a WNSIDEREDTIOOAI USAGE A MIL.I vtms CO IPRutn''' ,r I >a 0 Z Z Q Q WI— —Z CD LUJ--1 tT I1 n nn I1 Tl————ITIT IT(T 11 T1 Tl �._ iiiiiii►IIIIII IIIIIIIIIIIIIi LI II 11 LI 111,1,1...1._............_. 411 to II LI iJ.14 (.) 1` - a 6'J bi bb • II•r Y ..__ 11•r T 11'r mT,w rnoa�aw\ i DROPPED OW) 1 b 1 b I b I•�' F 1 F7. 9 F ENGINEERED FLOOR TRUSS HY OTHERS ASSUMED �S I j 1 ': 16'TRC'SS DEPTH �O l'- ti - § I 5 e M-7 T6• tvr tv-r �� F Ot�s s•t.tT I 70OV�0.01 OUND FLOOR ' .-......_....-.. C'}i 1{MSvt il R] WAILS YORBB BREAK AWAY' • Ri • 4 : • Fah it x� • 9 _ _ v�• -.• Fn 0-TO PV RFOUtREVI ENGINEERED FLOOR .ti.I.OxO TRUSS BY OTHERS iii. ® 16•TRUSS DEPDI - -�_: b ASSUMED F € "-- SQUARE Q6 ..__lr-S• 1 ITV i 1rr •i GEOLND MOON 1 I :t i 0 t PORCHES F ,I 1 A F I •SECOND PIOO • .t• � �•dd1 I (¢1.nT.ly N. II I I ` —'• ......._...�p4..... LAIR...._... DIDR®DYy. \" I • xxnT�. .,r1: rr . PORCHES- .! or I1'6' k- - 11'r \al,rt.®va }}{{ • 1 S Hen'1�----- L i ' • _ DBa 'ALL GROUND PLO( �_ _—r, b F®.SD®t_ �.=R WARS TO BE BRP.AKA �< .11} 1 tf IT DOPP® Al VIM ROUGH OPENING RE( i 11'r /' 11'r 1 11'%... !——-.' - t P�BIROR�'IO LAYING POUP�IDA�TI Nsr J3p PILE PLACEMENT PLAN -- ': °"lRP<,DsP ...-- fl,D,n PUIMBINGDIMELINEONSIONS SHOI APPAOX CENTERLINE OF PIX' 1 — 1 PLUMBER TO VERIFY DIENN sciaa=Y^=1.-o. —„.. FOUNDATION FRAMING/ ®®r D vn POsrAloN. (IT PIA DEPTH) It--——!i Oc AK FIRST FLOOR SUPPORT PLAN DIMENSIONS ARE PROM OUTS 4i'{ EXTERIOR WALLS TO CENTER "-Y""--..-- SCALE=y^=V-0" GIRDER.ONEDVENEERS OP ANY 4KE F. --— DIMENSIONED UNLESS OINSI /r —�„ RBMC Bvo sMOON WM/ ABB ANY F.t4H'BRIMS IN nus F-VGcumtp.o NOTED.VERIFY ALLRAPTINF ——— nm REroBEAM%HANG,.AND BNA1UNG FOR�1lmnussD��hS�E CONTACT CONNPE DMPTRK . ��� OP ANY DISCREPANCES PRIG CONSTRUCTION. IT IS THE SOLE.RESPONSIBILITY OP THE CONTRACTOR AND/OR BUIDER TO CONFORM TO ALL STANDARDS.PROVISIONS, ' NOTICE v./ PILE&FOUNDATION FRAMING Y REQUIREMENTS,METHODS OP CONSTRUCTION AND USES OP MATERIALS PROVIDED IN BUIDINGS AND/ORSTAUCNRPS AS T DRAWINGS UBS ONLYHE D D REQUIRED BY N.0 UNIFORM BUILDING CODS.LOCAL AGENCIES AND IN ACCORDANCE WITH GOOD ENGINEERING PRACTICES. TDTSSIRSPBOPIBDOPABIN,ANY RESIDENCEK + NEITHER CONNER DRAFTING&DESIGN NOR ANY OP ITS SUBCONTRACTORS ARE RESPONSIBLE FOR ANY PROBLEMS DUE TO NT OTHER IIO RE OrlOPIER.D. HUMAN ERROR AND/OR OMISSIONS ON mesa DOCUMENTS.IT IS THE OWNER AND/OR CONTRACTORS RESPONSIBILITY TO TITHER THAN INDICATED MOF . MURDOCK RESIDENCE u N ANORAWN OR MHO lETRaR . CAREFULLY REVIEW THESE PLANS POR ERRORS AND OMISSIONS PRIOR TO CONSTRUCTION.II ANY PROBLEMS ARE ROUND IN THE MANTvrounOHWui BE A� NIaEN°Aa^ REVIEW PLEASE NOTIFY CONNER DRAFTING AND DESIGN PRIOR TO BEGINNING CONSTRUCTION SO ANY REVISIONS CAN BE MADE DRBCTCOPVRIGHT � NW CM. BASSO ^v�m+r.Wuoom'a n'SI®®RINGALINVIONGDMINT LUUSA u+l a Mtmm Wum ®jTUDIAem N emD CM USAGE. ., ,,,.. 0 Z Z.- CD 0 LIJ I- > , -Z Ili- 0 2 ....... . [I li till III-I I 11111. ... cr§ . C.) '''•:, •tD 4.1::Deo..Arr MISS MTH 5/C DM nO.U.DOL SPKED 20 0.0 MAR.CAMS 1.01...........„.N. 1 r. •., •i § i t ••• A- o)-2.2pr.oaoenio WO PT.D.R.JOISTS sencEo 12 0.C. '..; E IW-1x12 11... TM— (1.1.1SY.E.LEL .CONTINUOUS FROM CORN.111 CORN.\., PROVIDE&JACKS(S/END OP..OPENING DTP)BACK WAIL . . i . ,. . 3 JAC. A , 1 i '1•••1 i i .: , ENGINEERED FLOOR,. ., . A i; • A SYSTI.BY OTHERS .. :. 1 t =1...4 1..1 ..===•=1:1' 1 I i i .. ABOVE • 11 .. ti I .. :• .. 6 I ,, <I, i .., SYSTEM BY OTFIERS,,,, ,, I,: ASSUMED d 1•,. " . 1,,,.. i: 'n II,• . RIDGE :: i i i • • • I i 14.H 1 i :, .• :, :. :: ""-e's---" -c`i(1.1 •, • :) .•.• IL...L..1i Li i..i_ul ..• :. , .,•, ft.„....... ...i i. i.i 1. .• - . : .•,......f.....,.....,, :] ', • .•: ,•• .1' tr-,17.,:-.7'. 1: i , ----, i.........___:: ft •• .1 ,1 :_____••••_,, APAM BY 011iBiS i I i I i T-TT-T1 1 i, .• i I i I • I' '''''''lrt""" —--,a R ,. . 1 •, . ,..4::::=ii ... . .. • ki "so......., ,. •' ... ‘6,, ,, tli . CALCULATIONS 1;.•11 1::::.11--.1==r1:11 .,.....,.. t...„ 'z, i ' i i , i ,,-- .--- F GROUND FLOOR ,,, • ATED • GARAGP 1,14=:=7.1:::=- = M 1 1I 17 .. ... .. .. : Ilt • I t • .: .•: 1 I 11111111111.111111.111.111 FORT FLOOR • HEATED L :. 1. • PORCHES 11 , . . •• 1 I .. . .•: ti .•: r: :: SECOND MOOR: t‘111.=====t 1 i .7--11 t. .•. I i • — R HEAT111.— . .. :.• •• , . . • POINTER 1 ? •• ,. ...,VICC WO,,AILEZ.VrrACialp 1 n•11.117EDER,, A i: '::.• 1: .- ,11;/1..,4{-•-•••••••1NR11:::..--=;1:. .1 1.-.1.-- ,.1111..1-111,...-11111:•—.11-"--. ..ANN11.1...;..1 S -•11 I i 'ALL GROUND FLO< z: ...M i 1. WAUS TO BE BREAK A -• Is o 1 11 1 ::.•... ALL D M INNT SIONS A REA FLLRSO.M C COVERED 5covE i FACE OF EXTERIOR WALLS AP PORCH IS ar UNOPRORWL , DOORANDWINDOWSARELC . THEIR APPROXIMATE OINTEI •01-2.12 P.DROPPED . AND WINDOW CUPS ARE IA 1 1....... ...10 (2) .... ... ...... .... . 1111 111113. , 'THIRD FLOOR SUPPORT&MAIN ROOF I THEIR NOMINAL SIZE,VERIFY DIMENSIONS AND CONTACT( DRAFTING dt DESIGN OF ANY DLSOLEPANCIES PRIOR TO CO: 3,cr SUPPORT PLAN TYPICAL CEILING HEIGHT OP (2}2.10 PT JOIST FIRST FLOOR AND 8,0"ON AD 1•10PTIOIST W111.1/ G°11'1".r."" SCALE=W=V-0" FLOORS UNLESS OTHERWISE I 0.0 CAME.. BEAMS BY 0111.3 ARE ANT PLUSW BEAM IN THE ENGINEERED CATHEDRAL CEILINGS,VAULT SECOND FLOOR FRAMING/ FLOOR STET.T.BE.A.HANGERS AND MI..FOR T.. BRANS..TIM RESPONSIBIIM OF TKE MSS MISION.R. AND/OR CHILD*TREYS AS N FLOOR PIAN. SUPPORT PLAN CONTRACTOR TO YOU/7 TIQ SCALE=y,^=r-o^ MEET EMERGENCY ESCAPE A OPENING REQUIREMENTS IN SLEEPING ROOM AND BEAMS BE OTTERS ARE ANT'FLUSH MARS IN WM ENGDWERED LIGHT/VENMATION REQUEll FLOOR SITIRAL IRS BRA.HANGUS AND BEARING PORTERS. (R303)IN EACH HABITABLE RC MANS ARE THE RESPONSIBILDT OF THERM.DESIGNER e -.r IT IS THE SOLE.RESPONSIBILITY OPTED CONTRACTOR AND/OR BUILDER TO CONFORM TO ALL STANDARDS,PROVISIONS. NOTICE .."2ND&3RD FLOOR FRAMING PLANS IMQUIREMENIS,METHODS OF CONSTRUCTION AND USES OF MATERIALS PROVIDED IN BUILDINGS AND/OR STRUCTURES AS PL. TIM DIAWING APPLES:S.1LT mugDocx e, D D REQURIED RING UNIFORM BUILDING CODE,LOCAL AGENCIES AND IN ACCORDANCE WITH GOOD ENGINEERING PRACTICES, TORRE WM SPECIFIED 11.11111, ANT OMER USE IS PROMEDID. RESIDENCE NEITHER CONNER DRAFTING&DESIGN NOR ANY OF ITS SUB-CONTRACTORS ARE RESPONSIBLE FOR ANY PROBLEMS DUE TO NO PARRIS.BR COKED, ...sr s crorna n•oe...., HUMAN ERROR AND/OR OMISSIONS ON THESE DOCUMENTS.IT IS THE OWNER AND/OR CONTRACTORS RESPONSIBILITY TO MuRDocK RESIDENCE OMER THAN INDICATED ERRE. PA WI 617 ucia....mtacaum CAREFULLY REVIEW THESE PLANS FUR ERRORS AND OMISSIONS PRIOR TO CONSTRUCTION.IP ANY PROBLEMS ARE POUND IN THE ANY VIOLATION WILL RE A ,,,,,, . P11.1.10.. SNP OTP. REVIEW PLEASE NOTIFY CONNER DRAFTING AND DESIGN PRIOR TO BEGINNING CONSTRUCTION SO ANY REVISIONS CAN BR MADE. D1RFLT COP. , IGITP 1./Cla CORP101,11tkerCli...0.03.14,,, lannatucemerrr AND a 0 .,„, DRAWN. I PERNA. 2017 all, ,CON90.1313 RI wr R•USAGE .u.,IS.. , A- U z G Q 0 W I.— aI LLI Z r - - STRUCTURAL PLAN NOTES U C TYPICAL OF ALL BANDS ANO GIRDERS I_LI—1 x INSTALL UT IN BRACES AS INDICTED ON THE FLOOR PLAN.LPL IN PRACIgi TO BP ly•PINE wrLH 5/IP DO.�LNG ALL PLATRSAND FLOUR PLOcer USEPS�. DWELLING +. MS AP EACH NORM WALL WPM LIMN TRLBRMIDICA EDONP AN __- __ ....._. ERA®RvaunDDN IABI.S. RINSMPGR�orsreLEPORNmRRYSTM•RaaeSYSTE U0 SPECIAL NOON TOTAL LOCALIZED SCORING ,y,,N, MAX WINO SINAIL 6.11.5 MAX HYDRAULIC LOADING_ D Do MPH uNrnE.ASR wa wB.DRIc IrDn3J._...._...__I.0 T . V\AIV) • 11"F LOCATION OP GROLND AdR WALs ! PER OmNWyCONIARC1OR AND AAR IV L.OU Porn IIDIN • IVINAL11 CAN 4. • er2 ALT,MAR BR��LAIL NO,A�rin BRACING LN�wxw BNING� G TOEBRACING DULL CONFORRMM WM AAPAT DESIGN. A • B -PI mmxsWren INNER mA 1. / +urge Rope 3HRATRX: RHiPiavcN.NAwc arvD�i ersnollHvxD ' HUBRICAimvm m OnRRSS DROPPEDJO MAMMA THE DOWNWARD,NO MORE THAN < Y '��m �� HT O SS NOIHD OIHH UNR��PVB TIERD FLOOR ROOF SUPPORT PLAN , R.�� 2c TYPICAL OF ALL PUPA SCA a_y,_l,-0, LopsnucruRAL ,......m. . a.o m n .R . r M ..... r�n • GROUND , PUN MILANO/ V noLLLAPRAT 11 y .a.WI/FM 19•GAGE MAD PLeoRt........Lvv 14,1AYS SECOND FLOOR IS I. wn®....Ivn�m • �a)mr \��'�,uMm,s WALLSIO BE B�HEAK Aw cdP �o R _ •• ALL DIMENSIONS ARE PROM OT •A�m rexRRo PACE OP EXTERIOR WALLS ANC • "'°"`a's"w LINE OF INTERIOR WALLS AIL. DOOR AND WINDOWS ARE IOC b ^� • THEIR APPROXIMATE CENTER. ^ AND WINDOW SIZES ARE LABEL 9 my w uAv..• THEIR NOMINAL SIZE VPEIEY/ ..... .. ......._. ......._ ........._.. ... DIMENSIONS AND CONTACT CC DRAFTING&DENGN OP ANY .ram.... Iv ... —_........._... DISCREPANCIES PRIOR TO CON \ �. , iv mrr.0 n..mc IYFICAI.CEILING HEIGHI'OP9 ,......, v TYPICAL OOR AND HEIGHT ON ADD �._. FLOORS UNLESS ODBEW68 N( CATHEDRAL CEILINGS.VAULTS Ira.A.W...— v...=e• AND/OR CEILING TREYS AS NO FLOOR PLAN .EXT.WAIL SECTION CONTRACOR TO VERIFY THAT C('AI P:j.]•j•$ MEET EMERGENCY ESCAPE AN OPENING REQUIREMENTS IN E SIEEPI IG ROOM AND LGHT/VFPTTIATION REQUIRE (R3Os IN EACH HABITABLE ROO IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND/OR BUILDER'TO CONFORM TO ALL STANDARDS.PROVISIONS. ""NOTICE 3RD FLOOR SUPPORT PLAN/DETAILS REQUIREMENTS.METHODS OP CONSTRUCTION AND USES OP MATERIALS PROVIDED IN BUILDINGS AND/OR STRUCTURES AS T DRAWING APPLIES ON,' — REQUIRED BY NC UNIFORM BUILDING CODE,LOLL AGENCIES AND IN ACCORDANCE WITH GOOD ENGINEERING PRACTICES. TO NM SITS SPENDER HEREIN RESIDENCE ocK G D V ANT OTHIT LS PROHIBITED. NEITHER CONNER DRAFTING&DESIGN NOR ANY OP TIS SUB CONTRACTORS ARE RESPONSIBLE POR ANY PROBLEMS DUE TO NO PART D TO BE COPIED, RIB°B"fnJe•Outl' PA/ORM HUMAN ERROR AND/OR OMISSIONS ON THESE DOCUMENTS.IT IS THE OWNER AND/OR CONTRACTORSRESPONSIBILITY RESPONSIBILITY TO ��I.REDRAWN ORO OTHE R THAN MUIDOCK RESIDENCE uo SETC:n CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS PRIOR TO)CONSTRUCTION.W ANY PROBLEMS ARE POUND IN THE ANYVIOUTIN WDI.RSA nhrt REVIEW PLEASE NOTIFY CONNER DRAFTING AND DESIGN PRIOR TO BEGINNING CONSTRUCTION SO ANY REVISIONS CAN BE MADE DIRECTCOPvuGII �� RIRBQn.rr< LLAG muagpiArnmOewooaoR., INIYINGCONSIDERED t'A B .n 1PCAIE i(..Ia DRAWNBT. ®IvnR.I ME l OIBDmD tC0 USAGE A RII ,.,, • vi WI > STRUCTURAL NOTES DETAIL NO.I-PILE BRACING DETAIL NO.2-DOUBLED PBS BRACING V DETAIL NO.2(ALTERNATE) ® DETAIL NO.I-TYPICAL PILE CONNECTION DETAIL NO.N-TYPICAL BUTT JOINT CONNECTION W GENERA• _ NORIOKALB I NOlTOAwB CA6IFRFSSION PITH BRACIING SCAM '�Y-BH �M � B TDB. �� B w�w°O°D°rn�YO N 9reR w. .N�n Ar.� d °„® NOT .,,....a °. do M W. _ _ _" .,��.. BOLT • Or COIIIILICWit«. °a ,� ,.N TION/.e„m.,4 ..Y �(� �ii { NUTS AND Y WARM. _ MAMMA.AD �nDDAGuDDrT..R.,,,,,,. ...",....� �� �J E �,, IV Ws NORTH AMU LIQUAIMIINTS �__ �: A� N oNn:i...Ar. _ _ti . <> ......... .. HIGH DOWS AND Dan.ilIA11,1.1,1l II.X CR/Inn.DM,: 1.1.....11,w�,Pi BAD,NABnAN..°o1. n.1B.roD... _e. r ,B ANS APPRDBDIDBG.ADBIEY.. DS SO a w� ��mm�a,.r°. °NF��BDB�BBAY r IT ..,°,�_,.r.RB�PmB,n,,,,Br ,,,,,,B,B... A 1,11.72EATIIIII WOOD BIRICISEIB SHALL BE TICATED rx Amp...4.will coo. I SIGN.(COM1,1 vlwlmro mvxIWINSAM OPT... DETAIL 5 TYPICAL END.CORNER OONNECITOIE Ad ro6-1YPIGAL FOUNDATION TJOAR CONNECTIONS DETAILNo.1 DETAIL L.I-GALVANIZED ANGLE BAND CONNECTIONS DETAIL.NO.9-TRILL PORCH HEADER CORNER TO SCAM SCNe GALVANLEPD SM. OVERHEAD vBn amea CONNECTIONS .o snL11gnI.r AxA eesTO GUIDBRCONNBCTICIN I„LTAS w AmD.DA„n,WD1INAI,rArnmA1 SPEDRUZNDI IIr WIDTHS,YA.M4. ,,,.°aars,.v a,�..aa o, mmclmmn _ �••••• w�.•.w: Biov rnlR Si.4 ..A> _....� oruleADve. s Isar ICABRA reri MUM MIND P.°p ...o ow,.., PATMPGL r..°. .CA.ItO11.3. .�. ..DBD.xB°�.•NC pi N �flu�r®W L I;S. Amwm°. RB ;�.e r-e,0.R� — ALL BE :.WiR��° ., � DL> TO _ DD,,,.No.w: .D. s�,.�.LD�,,..w�,�, V7' .�.... _ mDRyeAlm ORd1BCrION B n°t: 7 Mulamalale la �a o,,,,,N.BArro IIIIY IIIIY Umsuouals,rts sot w...�..,... .. .=K�a..N�..°N,..,. AND/OR ,A MR CR®virn DETAIL NO.IA-TYPICAL HEADER TO POST DETAIL NO.11-TYPICAL HEADER POST DETAI.NO.12-TYPICAL PORCH POSTCONNBCTION i BREAK AWAY TALLSPFffiICATIONS NOTTU SCALE • AIL RAN NSW N.urwv u,,,,,,N.ure,,,,AR.r,.,,,,,rrnn.swm,,,,,,i i1TH BUTT JOINT CONNECTION NOT TO Ewa „o.wi.vm A� ovBBxeAnv Dauavww NORIO SCAM __ Ia AM 0.5mDI mc,,AAA In• NOT ,,..v.nmv.'n name°.v.na.a.W ®` T.naaaa wv oc MBA',Suurn°rR,,,Cn°,,,,,,VGwn Nu,,COMn[rnl ,,,,,L0 C�� A•111 III meA. BALL BE B,Aus l IS liPOIITED D D� p�DaN ,°.AnN��mA.I ..,,A .�.�uN �B �. �.� a _ - _ir.X.150 WO __ Rrtlmlv r a P7 r�v —i2 �W,�.u0 ®wru.ruuv...ro �� Rrtm� '�I A _, AQBw ...,..SC °STANDARDr. a .B DW DDN DORMER DETAIL . 5.23.11.1...... ■I� "' _!WM. a =vans `ItJ/TYPICAL OVERBUILD CONNECTION DETAILS ti .. •• _r. .,,,I,B.A.„uA.,,,,,E,nDNBN..W...�. ,m..,�To Be V0.10Asu By Ay 1,74(BAIBC,.. __� I , B.�_ _ ` �© m.SHALL CONTIMAKE OR ulnas sr AT ALA AnIcx1 ...,...., '. ..uw ar.uxAve�,mana.,mwa®vvamwrn,,,r,tm�AT a` Mn -...._r.......... ▪ -��'I NR® IINBe BRACE DETAIL MineiNINNIMMiffliiiMi A.,.., WAY TO MINIMUM GRACIICIICC.BLIT 04 NO Cf.MALL JOINTS BB WADnAT IONIOaI1 A GARAGE RA,.SBI,I,B 51.,,p TCAVARIA5 GA.,.DOOR OpETIZAIG r,ACC,M.A.. IITIII OMB.GARAGE FLOOR MAT BA L.P.AT /R',AMYL',IfAIRTABIll AMA IN m,WnrllDnw0.11 Q,,.r.ND-^„1 B°�LUM IMOSILIN0 MID IS My COM IT IS THE SOLE RFSPONSRIIIlY OP THE CONIRACNR AND/OR BUILDER TO CONFORM TO ALL STANDARDS,PROVISIONS, LS• NOTICE ..orDETAI &NOTES .' REQUIREMENTS,METHODS OF CONSTRUCTION AND USES OF MATERIALS PROVIDED IN BUILDINGS AND/OR SIRUCTVAES AS nAN. DRAWING APPLIES ONLY URDOCK I� D NC.REQUIRED ByUNIFORM BUILDING CODE.LOCAL AGENCIES AND IN ACCORDANCE WITH GOOD ENGINEERING PRACTICEST.TO T AIIHSPB(IITRD NBR.., II THE 1AI ANT CAI..USE•PROHIBITED. RESIDENCE NEITHER CONNER DRAFTING&DESIGN NOR ANY OP ITS SUB-CONTRACTORS ARE RESPONSIBLE FOR ANY PROBLEMS DUE TO NO PART IS TO BE(DYER • .y HUMAN ERROR AND/OR OMISSIONS ON THESE DOCUMENTS.IT IS THE OWNER AND/OR CONTRACTORS RESPONSIBILITY TO rylpiBjI,,BI,uE REDRAWN NORUSED MURDOQCR6�@ICR .in r°^.'Ngrc a°. W CAREFULLY REVIE THESE PLANS FOR ERRORS AND OMISSIONS PRIOR TO CONSTRUCTION.IF ANY PROBLEMS ARE POUND IN THE NamK.,IIN REVIEW PLEASE NOTIFY CONNER DRAFTING AND DESIGN PRIOR TO BEGINNING CONSTRUCTION SO ANY REVISIONS CAN BB MADE A DnRCRCOPT1UGHT A � •I.arc•nc a•B.WAImnaA, mrnm.sxmur AND Is A GIDIT COD `TLI�ERED EIECALUBAGH w ,.,iDI MNO,.SMARMBY. ®I,msau "¢,n� Iiilliil NC Division of Coastal Management Cashier's Official Receipt 5403 A B Date: 16- 20 Received From: DPCN I L IAA 0 1)0 $ 1/0-0 Permit No.: _j Check No.: v5---- _ Applicant's Name: VJ\ L Y ''\'.-' DOoff- County: ) r . Project Address: it IQ 3 9 1� vL I , " Please retain receipt for your records as proof of payment for permit issued. Signature of Agent or Applican • Date: ( i 3 ‘ I Signature of Field Representative: Date: Date Date Check From Name of Vendor Check Check Permit Number NOTES Received Depos (Name) Permit Holder Number amount ited 11/15/2017 Daniel same Four 1856 $100.00 minor fee, 7063 7th St. JD rct. Murdock & Oaks SC ONsCo 5403E Kathryn Bank Dunlop