Loading...
HomeMy WebLinkAboutO-12-30_Brown, Bill & Stroud Engineering_20121130' —k Atlantic Beach Local Government 0.12.30 Permit Number CAMA MINOR DEVELOPMENT PERMIT as authorized by the State of North Carolina, Department of Environment, and Natural Resources and the Coastal Resources Commission for development In an area of environment concern pursuant to Section 113A-118 of the General Statutes, "Coastal Area Management' Issued to Bill Brown and Stroud Engineering for development in the Ocean Hazard (AEC) at 112 Ocean Drive in Atlantic Beach, as requested in the permittee's application, dated November 13, 2012. This permit, issued on November 30, 2012 is subject to compliance with the application and site drawing (where consistent with the permit), all applicable regulations and special conditions and notes set forth below. Any violation of these terms may subject permittee to a fine, imprisonment or civil action, or may cause the permit to be null and void. This permit authorizes: the construction of a new single family home at 112 Ocean Blvd in Atlantic Beach. (1) All proposed development and associated construction must be done in accordance with the permitted work plat drawings(s) dated received on November 13, 2012. (2) All construction must conform to the N.C. Building Code requirements and all other local, State and Federal regulations, applicable local ordinances and FEMA Flood Regulations. (3) Any change or changes in the plans for development, construction, or land use activities will require a re-evaluation and modification of this permit. (4) A copy of this permit shall be posted or available on site. Contact this office at (252) 726-4456 for a final inspection at completion of work. (Additional Permit Conditions on Page 2) This permit action may be appealed by the permittee or other qualified persons within twenty (20) days of the issuing date. From the date of an appeal, any work conducted under this permit must cease until the appeal is resolved. This permit must be on the project site and accessible to the permit officer when the project is inspected for compliance. Any maintenance work or project modification not covered under this permit, require further written permit approval. All work must cease when this permit expires on: DECEMBER 31, 2015 In issuing this permit it is agreed that this project is consistent with the local Land Use Plan and all applicable ordinances. This permit may not be transferred to another party without the written approval of the Division of Coastal Management. Jessica Fiester, MPA, CZO CAMA LOCAL PERMIT OFFICIAL PO Box 10 Atlantic Beach, NC 28512 PERMITTEE (Signature required if conditions above apply to permit) Jan 281 q 04:54p, Town of AB Inspections Name: Bill BrownlStroud Engineering Minor Permit # 0-12-30 Date: November 30, 2012 Page 2 252-727-7043 p.1 (5) The permittee is required to contact the Local Permit Officer (252) 726-4456 shortly before he plans to begin construction to arrange a setback measurement that will be effective for sixty (60) days barring a major shoreline change. Construction must begin within sixty (60) days of the determination or the measurement is void and must be redone. (6) All buildings constructed within the ocean hazard area shall comply with the NC Building Code, including the Coastal and Flood Plain Construction Standards of the N. C. Building Code, and the Local Flood Damage Prevention Ordinance as required by the National Flood Insurance Program. If any provisions of the building code or a flood damage prevention ordinance are inconsistent with any of the following AEC standards, the more restrictive provision shall control. (7) All buildings must be elevated on pilings with a diameter of at least 8 inches in diameter if round, or 8 inches to a side if square; and the first floor level of the sills and joists must meet the 100-year flood level elevation. (8) All pilings shall have a tip penetration greater than eight feet below the lowest ground elevation under the structure. (10)Dune disturbances will be allowed only to the extent necessary for development and if the dune's protective value is not weakened or reduced. Disturbed dune areas will be immediately stabilized. (11)AII unconsolidated material resulting from associated grading and landscaping shall be retained on site by effective sedimentation and erosion control measures. Disturbed areas shall be vegetatatively stabilized (planted and mulched) within 14 days of construction completion. (12)Any structure authorized by this permit shall berelocated or dismantled when it becomes imminently threatened by changes in shoreline configuration. The structure(s) shall be relocated or dismantled within two years of the time when it becomes imminently threatened and in any case upon its collapse or subsidence. However, if natural shoreline recovery or beach renourishment takes place within two years of the time the structure becomes imminently threatened, so that the structure is no longer imminently threatened, then it need not be relocated or dismantled at that time. This condition shall not affect the permit holder's right to seek authorization of temporary protective measures allowed under CRC rules. Signature: Date: GENERAL INFORMATION LAND OWNER Name TRIPLIQUESE VENTURES, LLC - BILL BROWN Address P.O. BOX 1198 City Email MOREHEAD CITY State NC Zip 28557 Phone (252)241-9568 AUTHORIZED AGENT Name STROUD ENGINEERING PA RECEIVED J. NOV 15 2012 Address 151-A HIGHWAY 24 City MOREHEAD CITY State NC Zip 28557 Phone 252-247-7479 Email RCULLIPHER@STROUDENGINEER.COM LOCATION OF PROJECT. (Address, street name and/or directions to site. If not oceanfront, what is the name of the adjacent waterbody.) 112 OCEAN BLVD, ATLANTIC BEACH, NC DESCRIPTION OF PROJECT: (List all proposed construction and land disturbance.) SINGLE FAMILY HOME SIZE OF LOT/PARCEL: 7587.78 square feet .174 acres PROPOSED USE: Residential ® (Single-family ® Multi -family ❑) Commercial/Industrial ❑ Other ❑ COMPLETE EITHER (1) OR (2) BELOW (Contact your Local Permit Officer iryou are not sure which AEC applies to your property): 1829.05 (1) OCEAN HAZARD AECs: TOTAL FLOOR AREA OF PROPOSED STRUCTURE: square feet (includes air conditioned living space, parking elevated above ground level, non -conditioned space elevated above ground level but excluding non -load -bearing attic space) (2) COASTAL SHORELINE AECs: SIZE OF BUILDING FOOTPRINT AND OTHER IMPERVIOUS OR BUILT UPON SURFACES: square feet (includes the area of the roof/drip line of all buildings, driveways, covered decks, concrete or masonry patios, etc. that are within the applicable AEC. Attach your calculations with the project drawing.) STATE STORMWATER MANAGEMENT PERMIT: Is the project located in an area subject to a State Stormwater Management Permit issued by the NC Division of Water Quality? YES NO X If yes, list the total built upon area/impervious surface allowed for your lot or parcel: square feet. OTHER PERMITS MAY BE REQUIRED: The activity you are planning may require permits other than the CAMA minor development permit, including, but not limited to: Drinking Water Well, Septic Tank (or other sanitary waste treatment system), Building, Electrical, Plumbing, Heating and Air Conditioning, Insulation and Energy Conservation, FIA Certification, Sand Dune, Sediment Control, Subdivision Approval, Mobile Home Park Approval, Highway Connection, and others. Check with your Local Permit Officer for more information. STATEMENT OF OWNERSHIP: I, the undersigned, an applicant for a CAMA minor development permit, being either the owner of property in an AEC or a person authorized to act as an agent for purposes of applying for a CAMA minor development permit, certify that the person listed as landowner on this application has a significant interest in the real property described therein. This interest can be described as: (check one) TRIPLIQUESE VENTURES, LLC X an owner or record title, Title is vested in C/O BILL BROWN ,see Deed Book 1159 page 431 in the CARTERET County Registry of Deeds. an owner by virtue of inheritance. Applicant is an heir to the estate of probate was in County. if other interest, such as written contract or lease, explain below or use a separate sheet & attach to this application. NOTIFICATION OF ADJACENT PROPERTY OWNERS: I furthermore certify that the following persons are owners of properties adjoining this property. I affirm that I have given ACTUAL NOTICE to each of them concerning my intent to develop this property and to apply for a CAMA permit. (Name) (Address) (1) STRUYK PROPERTIES, LLC 727 ARENDELL STREET, MOREHEAD CITY, NC 28557 (2) DUSTIN G TYSON 1307 HWY 70 EAST, NEW BERN, NC 28560, (3) t :lea:. " (4) 2012 ACKNOWLEDGEMENTS: I, the undersigned, acknowledge that the land owner is aware that the proposed development is planned for am4rAa',' "1TY may be susceptible to erosion and/or flooding. I acknowledge that the Local Permit Officer has explained to me the particu- lar hazard problems associated with this lot. This explanation was accompanied by recommendations concerning stabiliza- tion and floodproofing techniques. I furthermore certify that I am authorized to grant, and do in fact grant, permission to Division of Coastal Management staff, the Local Permit Officer and their agents to enter on the aforementioned lands in connection with evaluating information related to this permit application. This the 9TH day of NOV , 20 12 or person authorized to act as his/her agent for purpose of filing a CAMA permit application This application includes: general information (this form), a site drawing as described on the back of this application, the ownership statement, the Ocean HazardAEC Notice where necessary, a check for $100.00 madepayable to the locality, and any information as may be provided orally by the applicant. The details of the application as described by these sources are incorporated without reference in any permit which may be issued Deviation from these details will constitute a violation of any permit. Arty person developing in an AEC without permit is subject to civil, criminal and administrative action. ea Zon'Ing' 125 West Pow i acon Road.* A la -tic .Beach,,, N°� 28512- .. _.. Date _ --.�•.r.�«�..�.�t T l .•ram � .. ..�. �.. j. � emaxks: �easP rOn Number of Wages :Cover Tnclu�ed) --- =-- ----- - ' - -. Ozxgvu -too dsv-b -nail. The r�ornratzon contained-17i tJiisfacsimile-isprivileged4nfc tio€r4ntandetiozrlyfor-thc-fud&kILa12r— entrty named a�ve f nd reader -of •tills; message not the intended recipient, you are hereby notified that tiny cieczizon , drstribuiron or copy of this comiGcsictly prohibited_If y_ou have received this communication lit error, please notify trs immediately. -' - ------ ' Yosr-(7ffice'Eox o'o Atlantic Beach, -North CaroIina 28512 o phone (252) 726-4456 e Fax (252) 727-7043 TOWN OF ATLANTIC BEACH INSPECTION & PLANNING DEPARTMENT 125 WEST FORT MACON ROAD ATLANTIC BEACH, NORTH CAROLINA NOTICE OF FILING OF APPLICATION FOR CAMA MINOR DEVELOPMENT PERMIT r RECEWED NOV 15 2012 } ACM MHD cny Pursuant to NCGS 113A-119(b), the Town of Atlantic Beach, a locality authorized to issue CAMA permits in Areas of Environmental Concern, hereby gives NOTICE that on November 13, 2012, Stroud Engineering and Bill Brown applied for a CAMA permit to build a new single family dwelling at 112 Ocean Blvd. in Atlantic Beach. The application may be inspected at the address below. Public comments received by November 30, 2012 will be considered. Later comments will be accepted and considered up to the time of permit decision. Project modifications may occur based on further review and comments. Notice of the permit decision in this matter will be provided upon written request. Jessica A. Fiester CAMA Local Permit Officer for Town of Atlantic Beach 125 West Fort Macon Road PO Box 10 Atlantic Beach, NC 28512 PLEASE PUBLISH ON: Friday, November 16, 2012 POST OFFICE BOX 10 - ATLANTIC BEACH, NORTH CAROLINA 28512 • (252) 726-4456 • FAX (252) 727-7043 f • r HP OfficeJet Pro 8600 N911 n Series Last Transaction Date Time Type Station ID Fax Log for Town of AB Inspections 252-727-7043 Nov 13 201212:51 PM Duration Pages Result Digital Fax Nov 13 12:50PM Fax Sent 97262653 1:10 2 OK N/A o& RECEMD NOV 15 2012 DCM MHD CITY ''/r�N OF ,,,,ot �O ,gTsc • � • 1937.7�i00 TOWN OF ATLANTIC BEACH INSPECTION & PLANNING DEPARTMENT November 13, 2012 125 WEST FORT MACON ROAD ATLANTIC BEACH, NORTH CAROLINA Stroud Engineering Attn: Jonathan Roberts 151-A Highway 24 Morehead City, NC 28557 Dear Mr. Roberts: The N.C. Division of Coastal Management hereby acknowledges receipt of your application for State approval for minor development of property located at 112 Ocean Blvd in Atlantic Beach in Carteret County. It was received complete on November 13, 2012 and appears to be adequate for processing at this time. The deadline for making a permit decision is November 30, 2012 NCGS 113A-119(b) requires that Notice of an application be posted at the location of the proposed development. You were given a "Notice of Permit Filling" postcard which must be posted at the property of your proposed development. You should post this notice at a conspicuous point along your property where it can be observed from a public road. Some examples would be: Nailing the notice card to a telephone pole or tree along the road right-of- way fronting your property; or at a point along the road right-of-way where a private road would lead one into your property. Failure to post this notice could result in an incomplete application. An onsite inspection will be made, and if additional information is required, you will be notified. Please contact me if you have any questions. Sincerely, )L�ca A. Fiester I�Q CAMA Local Permit Officer f Town of Atlantic Beach ZIOZ 9 T A ON r k. Enclosure�� Xc: Heather Styron, DCM Field Representative POST OFFICE BOX 10 • ATLANTIC BEACH, NORTH CAROLINA 28512 • (252) 726-4456 • FAX (252) 727-7043 Nr i. 1 -1 o I 1 (01; 14 CAMA PERMIT APPLIED FO1�� COMMENTS ACCEPTED THROUGH Mo\jem6(- �a, go a,� 6 fr, � 0 WaLl Aw elA�, Alc �a FOR MORE DETAILS CONTACT THE LOCAL PERMIT OFFICER BELOW: �eSSxca, 17-7lr 6,6 _ IFo xAIC l o Project Is In An: AEC- HAZARD NOTICE . Ocean Erodible Area High Hazard Flood Area Inlet Hazard Area Property Owner: Property Address: a C')CeQCI &au\evc d /�}� (�'� lc.�`7P�'.tC�i %UC oZ� S%Q, Date Lot Was Platted: This notice is intended to make you, the applicant, aware of the special risks and conditions associated with development in this area, which is subject to natural hazards such as storms, erosion and currents. The rules of the Coastal Resources Commission require that you receive an AEC Hazard Notice and acknowledge that notice in writing before a permit for development can be issued. The Commission's rules on building standards, oceanfront setbacks and dune alterations are designed to minimize, but not eliminate, property loss from hazards. By granting permits, the Coastal Resources Commission does not guarantee the safety of the development and assumes no liability for future damage to the development. Permits issued in the Ocean Hazard Arp--r" Environmental Concern include the c`diri -``-- M� relocated or dismantled if the - changes in shoreline confil relocated.or dismantled W. \p y imminently threatened, and c. �(1-e subsidence. The best available informatit Resources Commission, indic average ocean erosion rate for located is 2_ feet per year. �C The rate was established by carefu of the coastline taken over the pas Studies also indicate that the shorel Qfeet landward in a major s The floodwaters in a major storm ai io be about .i � feet deep in this area. Preferred oceanfront protection measures are beach nourishment and relocation of threatened structures. Hard erosion control structures such as bulkheads, seawalls, revetments, groins, jetties and breakwaters are prohibited. Temporary sand bags may be authorized under certain conditions. The applicant must acknowledge this information and requirements by signing this notice in the space below. Without, the proper signature, the application will not be complete. SPECIAL NOTE: This hazard notice is required for development in areas subject to sudden and massive storms and erosion. Permits issued for development in this area expire on December 31 of the third year, following the year in which the permit was issued. Shortly before work begins on the project site, the Local Permit Officer must be contacted to determine the vegetation line and setback distance at your site. Ifthe property has seen little change since the time of permit issuance, and the proposed development can still meet the setback requirement, the LPO will inform you that you may begin work. Substantial progress: on the project must be made within 60 days of this setback determination, or the setback must be remeasured. Also, the occurrence of a major ; change as the result of a storm within the 60-day period issitate remeasurement of the setback. It is important heck with the LPO before the permit expires for official to continue the work after the permit has expired. if foundation pilings have been placed and substantial continuing, permit renewal can be authorized. It is continue work after permit expiration. formation, contact. 3�co" i es Viicer )OX 10 1 GCh- t� C ass _vcality J Phone Number �-*b l�CE1V�A A�. NOV 15 2012 DCM-MHD CITY Applicant Signature Date Revised 2107 A �..; r NCDENR North Carolina Department of Environment and Natural Resources Division of Coastal Management Michael F. Easley, Govemor James H. Gregson, Director William G. Ross Jr., Secretary Date 11/7/12 Name of Property Owner Applying for Permit: Tripliquese Ventures, LLC - Bill Brown Mailing Address: P.O.Box 1198 Morehead City, NC 28557 I certify that I have authorized (agent) Stroud Engineering, P.A. NOV 15 2012 DCM-AIHD CITY to act on my behalf, for the purpose of applying for and obtaining all CAMA Permits necessary to install or construct (activity) single family home at (my property located at) 108 & 112 Ocean Blvd, Atlantic Beach, NC This certification is valid thru (date) 11 / 8 / 13 Property Owner Signature 1-9-/Z Date 400 Commerce Avenue, Morehead City, North Carolina 28557 Phone: 252-808-28081 FAX: 252-247-33301 Internet: www.nccoastalmanagement.net An Equal Opportunity 1 Affirmative Action Employer— 50% Recycled 110% Post Consumer Paper )ASTAL BUILDING 110812Lot 7 1 11/8/12 1328 ..0 S E. NOV 15 2012 DCLRD cs :y 1328 11/8/12 '100.00 -- 100.00 r Tov n of Atlantic Beach i 11@0000 13-2�Gn' +1:0 5 3 lot, 5 681: 1 20 13 90 9 9 6 u' ------ `�1;3 8 nT� COPIES DATE NO. DESCRIPTION Nu :b Wrr THESE ARE TRANSMITTED as checked below: V For approval ❑ Approved as submitted ❑ For your use ❑ Approved as noted ❑ As requested ❑ Returned for corrections ❑ For review and comment ❑ ❑ FORBIDS DUE REMARKS ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return -corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US PI cGsc lel wr kaaL-. rf Yoiw Le_ and d(* OAS . COPY TO SIGNED: if enclosures are not as noted, kindly notl us at once. CLEAN FILL OR SAND (NO CLAY) PROPEX 111F (OR EQUAL) MONOFILAMENT FABRIC EXCAVATE ADDITIONAL Z AND REPLACE WITH CLEA SAND BEFORE RAIN TANK INTALLATION TYPICAL RAINTANK SECTION A —A SCALE: NTS END VIEW OF PIPE/FABRIC CONNECTION. CUT AN "X" IN THE FABRIC SLIGHTLY LARGER THAN PIPE. PULL THE FABRIC AROUND THE PIPE TO CREATE THE "BOOT" AND THEN SECURE WITH A HOSE -CLAMP.-__.. "X" CUT IN THE INLET/OUTLET FABRIC TO ALLOW PIPE PIPE/TANK INTERFACE VGEOTEXTILE FABRIC LEGEND GEOTEXTILE FABRI OVER D-RAINTANK] NON -CORROSIVE HOSE CLAMP OR TAPE USED TO FASTEN LINER TO PIPES TO PREVENT BACKFILL FROM ENTERING STRUCTURE ON -CORROSIVE HOSE LAMP OR TAPE USED TO ASTEN LINER TO PIPES 0 PREVENT BACKFILL ROM ENTERING TR CCTURE ;EO�EXTILE 'ABRIC OVER IA I NTANK* RAINTANK INLET/OUTLET DETAIL WITH OPTIONAL CONNECTOR PLATE Z 2 SCALE: NTS w 3 O AC ACRES AEC AREA OF ENVIRONMENTAL CONCERN CL CENTERLINE DIA DIAMETER - SEPTIC AREA DIP DUCTILE IRON PIPE EL ELEVATION PROPERTY LINE EP EDGE OF PAVEMENT -- — — — SETBACK LINE EX. EXISTING FE FINISHED ELEVATION GV I NV GATE VALVE INVERT - _..., ACF RAINTANKS LF LINEAR FEET MB MBL MAP BOOK MINIMUM BUILDING r LINE EXISTING 10' MIN MINIMUM / �I UTILITY EASEMENT N/F NOW OR FORMERLY I- -- NTS NOT TO SCALE OC ON CENTER - - -� PC POINT OF CURVATURE PG PAGE PERVIOUS PAVERS PSI POUNDS PER SQUARE INCH PVC POLY VINLY CLORIDE 0 FLOW R RADIUS RCP REINF. CONC. PIPE RED REDUCER ROW RIGHT-OF-WAY TBO TEMPORARY. BLOW OFF TT TAPPING TEE TYP TYPICAL V VELOCITY SHEET # 1 OF 1 PROJECT #: PM636-65 DESIGN FILE #: PM636-65 TRIPLE ESS SHORES SW C E AEI B L V D EXISTING UTILITY EASEMENT - --"-'------____-_- _ - - � 1 1 PROPOSED GUTTER 1 1 SYSTEM 1 i 1 1 PROPOSED 1 1 DOWNSPOUT r FL4" PVC ROOF 1 W LEADER @ 1.0% , J i t i PROPOSED 1 DOWNSPOUT I 1 a w 4" PVC ROOF I LEADER @ 1.0% I FLOW I PROPOSED GUTTER I r� SYSTEM I o s r � - 4" DOWNSPOUT FOR ROOF DRAINAGE " OVERFLOW TO ACF RAINTANKS DOWNSPOUT OVERFLOW SCALE: NTS PROPOSED L A �3 DOWNSPOUT] a FL OW 1 �- (37) ACF ATLANTIS SINGLE RAIN TANKS (SEE DETAIL) I 4" PVC ROOF 1 LEADER @ 1.0% � o 1 � 1 •�,�• FLOW PROPOSED DOWNSPOUT P OPOSED GUTTER SYSTEM 00 Ln Ln t� C- (V O r-- 1�j V) w w �J0 O PL. AN VIEW 27" FAffA IrI$ �1I� ,�11ip1h�1►i�l FRONT VIEW ISOMETRIC VIEW FOR CONCEPTUAL ASSEMBLY. SEE EXPLODED VIEW FOR SINGLE MODULE DIMENSIONS SHOWN SIDE S 8 5 3 1 "E 160. w ARE NOMINAL MODULE , DATA REFER SINGLE MODULE DATA GEOMETRY: LENGTH = 26.97 IN. (685 MM) LOAD RATING: 34 PSI, (MODULE ONLY) - - _ WIDTH = 16.06 IN. (408 MM) H-20, (WITH ACF COVER HEIGHT = 17.72 IN. (450 MM) SYSTEM) - STORAGE VOLUME = 4.22 CF MATERIAL: I� _I VOID INTERNAL VOLUME: 95% 85% RECYCLED VOID SURFACE AREA: 90% POLYPROPYLENE r-1 , I, fl I 1 Ifll l; PROPOSED II I DOWNSPOUT fLC 1 'I '— I 1 " 4" PVC ROOF I ; LEADER @ 1.0% 1 ,I r I; II ; II !; I I PROPOSED DOWNSPOUT 11 FLOW I �, if 4" PVC ROOF fl LEADER @ 1.0% PROPOSED fr DOWNSPOUT n 1� A A II Ij r 3 it I i FLOW o I, PROPOSED GUTTER SYSTEM u , (37) ACF ATLANTIS SINGLE RAIN TANKS ( SEE DETAIL) li I , n lI 4" PVC ROOF o " LEADER @ 1.0% L 1 , PROPOSED FLOW DOWNSPOUT �•�,�• ! p u I! +, I� if 60, qM S '`� C1 S75°3o, 5p 54 11E • 77 00 Ln �-- m �o CV Ln O r a - NOTES: 1. BOUNDARY INFORMATION TAKEN FROM SURVEY BY JAMES I. PHILLIPS OF JAMES I. PHILLIPS LAND SURVEYING, P.A. ENTITLED MACK BAKER DATED 12-20-05 2. INSTALLATION OF RAINTANK SHALL BE PERFORMED BY LICENSED CONTRACTOR IN ACCORDANCE WITH NC BUILDING CODE, ACF RAINTANK MANUFACTURERS INSTALLATION INSTRUCTIONS, TOWN AND COUNTY REGULATIONS 3. UPON COMPLETION CONTRACTOR SHALL NOTIFY STROUD ENGINEERING PA FOR FINAL INSPECTION 4. RAINTANKS & PIPING LOCATIONS MAY BE FIELD ADJUSTED TO PRESERVE EXISTING TREES WITH APPROVAL OF ENGINEER. STORMWATER DESIGN CALCULATIONS: TOTAL LOT AREA = 7,587.78 SF(0.174 AC) IMPERVIOUS AREA PROPOSED HOUSE = 1,829.05 SF TOTAL IMP. = 1.829.05 SF (24.1%) ------------------------------------- ROOF RUNOFF (1.829.05 SF) 2" RAINFALL VOLUME = 304.83 CF SINGLE RAINTANK VOLUME = 4.22 CF RAINTANKS REQUIRED = 73 RAINTANKS PROVIDED = 74 NOTE: CONTRACTOR SHALL NOTIFY THE ENGINEER UPON COMPLETION FOR INSPECTION. S 75 CARO'•.,* 10 5 0 10 20 =� � °SS�°"%'�9 * ¢ sEAL • i33as ? SCALE: 1 — °2 � 1 0 GIN 'o4'E�:�''•'•Z' �•, * ��4 f). CV 0% RECEIVED s NOV 15 2012 ACM-MHD CITY REVISIONS: