Loading...
HomeMy WebLinkAbout57907_NC DOT_20110701❑CAMA / ❑ DREDGE & FILL GENERAL PERMIT Previous permit# ❑New ❑Modification [-]Complete Reissue ❑Partial Reissue Date previous permit issued As authorized by the State of North Carolina, Department of Environment and Natural Resources and the Coastal Resources Commission in an area of environmental concern pursuant to I SA NCAC -V)7 ❑Rules attached. Applicant Name Project Location: County Address City State ZIP Phone # O Fax # ( ) Authorized Agent Affected ❑ CW ❑ EW ❑ PTA ElOEA ❑ HHF ElIH AEC(s): ❑ PWS: ❑ FC: ORW: yes / no PNA yes / no Type of Project/ Activity Pier (dock) length Platform(s) Finger pier(s) Groin length number Bulkhead/ Riprap length avg distance offshore max distance offshore Basin, channel cubic yards_ Boat ramp Boathouse/ Boatlift Beach Bulldozing Other ❑ ES ❑PTS ❑ UBA ❑ N/A Crit.Hab. yes / no Street Address/ State Road/ Lot #(s) Subdivision City ZIP Phone # O River Basin Adj. Wtr. Body (nat /man /unkn) Closest Maj. Wtr. Body (Scale: : ) Shoreline Length SAV: not sure yes no Sandbags: not sure yes no Moratorium: n/a yes no, Photos: yes no Waiver Attached: yes no A building permit may be required by: Notes/ Special Conditions Agent or Applicant Printed Name See note on back regarding River Basin rules. r PermitOfficer's Signature Signature Please read compliance statement on back of permit ** Issuing Date Application Fee(s) Check# Local Plan ningJurisdiction L Expiration Date Rover File Name Statement of Compliance and Consistency This permit is subject to compliance with this application, site drawing and attached general and specific conditions. Any violation of these terms may subject the permittee to a fine or criminal or civil action; and may cause the permit to become null and void. This permit must be on the project site and accessible to the permit officer when the project is inspected for compliance. The applicant certifies by signing this permit that 1) prior to undertaking any activities authorized by this permit, the applicant will confer with appropriate local authorities to confirm that this project is consistent with the local land use plan and all local ordinances, and 2) a written statement or certified mail return receipt has been obtained from the adjacent riparian landowner(s) . The State of North Carolina and the Division of Coastal Management, in issuing this permit under the best available information and belief, certify that this project is consistent with the North Carolina Coastal Management Program. River Basin Rules Applicable To Your Project: ['Tar - Pamlico River Basin Buffer Rules ❑ Other: ❑ Neuse River Basin Buffer Rules If indicated on front of permit, your project is subject to the Environmental Management Commission's Buffer Rules for the River Basin checked above due to its location within that River Basin. These buffer rules are enforced by the NC Division of Water Quality. Contact the Division of Water Quality at the Washington Regional Office (252-946-6481) or the Wilmington Regional Office (910-796-7215) for more information on how to complywith these buffer rules. Division of Coastal Management Offices Raleigh Office Morehead City Headquarters Mailing Address: 400 Commerce Ave 1638 Mail Service Center Morehead City, NC 28557 Raleigh, NC 27699-1638 252-808-2808/ 1-888ARCOAST Location: Fax: 252-247-3330 2728 Capital Blvd. Raleigh, NC 27604 919-733-2293 Fax: 919-733-1495 (Serves: Carteret, Craven, Onslow -above New River Inlet- and Pamlico Counties) Elizabeth City District 1367 U.S. 17 South Elizabeth City, NC 27909 252-264-3901 Fax: 252-264-3723 (Serves: Camden, Chowan, Currituck, Dare, Gates, Pasquotank and Perquimans Counties) Washington District 943 Washington Square Mall Washington, NC 27889 252-946-6481 Fax: 252-948-0478 (Serves: Beaufort, Bertie, Hertford, Hyde, Tyrrell and Washington Counties) Wilmington District 127 Cardinal Drive Ext. Wilmington, NC 28405-3845 910-796-7215 Fax: 910-395-3964 (Serves: Brunswick, New Hanover, Onslow -below New River Inlet- and Pender Counties) Revised 08/09106 BUFFER AUTHORIZATION CERTIFICATION FOR BRIDGE REPLACEMENT PROJECTS A riparian buffer authorization is required for bridge replacement activities within the Neuse and Tar - Pamlico River basins per Division of Water Quality (DWQ) regulations 15A NCAC 028.0233 &.0259, The Division of Coastal Management (DCM) through a Memorandum of Understanding with the Division of Water Quality (DWQ) has reviewed your project proposal, determined that the project as proposed complies with the aforementioned regulations, and made a "no practical alternatives' determination per those regulations. Those activities covered by your Coastal Area Management Act (CAMA) permit have received Buffer authorization as long as the project is constructed in a manner that continues to meet all of the conditions listed below. Failure to comply with this Buffer Authorization shall subject the property owner & the party (contractor) performing the construction &/or land clearing to a civil penalty of up to $25,000 per day per violation. 1) All stormwater runoff shall be directed as sheetflow through stream buffers at non-erosive velocities, unless otherwise approved by this certification. 2) All riparian buffers impacted by the placement of temporary fill or clearing activities shall be restored to the preconstruction contoups and re -vegetated. Maintained buffers shall be permanently re - vegetated with non -woody species by the end of the growing season following completion of construction. For the purpose of this condition, maintained buffer areas are defined as areas within the transportation corridor that will be subject to regular NCDUT maintenance activities including mowing. The area with non -maintained buffers shall be permanently re -vegetated with native woody species before the next growing season following completion of construction. 3) Pursuant to NCAC15A 2B .0233 & .0259, sediment and erosion control devices shall not be placed in Zone 1 of any Neuse or Tar -Pamlico Buffer without prior approval by NCDWQ. At this time, NCDWQ has approved no sediment and erosion control devices in Zone 1, outside of the approved project impacts, anywhere on this project. Moreover, sediment and erosion control devices shall be allowed in Zone 2 of the buffers provided that Zone 1 is not compromised and that discharge is released as diffuse flow. 4) Bridge deck drains shall not discharge directly into the stream. Stormwater shall be directed across the bridge and pre-treated through site -appropriate means (grassed swales, pre -formed scour holes, vegetated buffers, etc.) before entering the stream. Please refer to the most current version of Stormwater Best Management Practices. By your signature below you agree to be held responsible for meeting all of the above listed conditions and verify that all information is complete and accurate. Agent or Appli ant Printed Name Agent 0 Ap 0 ica t ignature CAMA GENERAL PERMIT#: 6" Ndte: PIevl.re� flcf�.r zcelv.e..Q oil Permit Officer's Signature —7—j'')! Issue Date I— I o [)- ort <+'N'") /Tu rf ^. r`I2a?I k, m NCDOT B-5202 BEAUFORT COUNTY REPLACE BRIDGE NO. 18 NC 99 (PUNGO RD) OVER INTERCEPTING CANAL BETWEEN SR 1625 AND SR 1629 CAMA GP, NWP 3, AND BUFFER AUTHORIZATION APPLICATION WBS ELEMENT NUMBER 45300JJ SCALE: /'=30' (FULL-SIZE 22'X34') SCALE: I'=60' (HALF-SIZE 11717') MARCH 29, 2011 FOR PERMITTING ONLY: NOT FOR CONSTRUCTION B/ COASTAL WETLAND IMPACTS = 0 Sq. Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. FILL REMOVAL = /06 Sq.Ft. SI STREAM IMPACTS = 125 LINEAR Ft. S2 STREAM IMPACTS = 225 Sq.Ft. PILINGS IN CANAL + RIPRAP BUFFER ZONE /IMPACTS = 5/0 Sq.Ft. BUFFER ZONE 2 IMPACTS = 320 Sq. Ft. L Z w ENERGY DISSIPA STD. DWG. 876.02 DIFFUSE FLOW THROUGH 15' SPECIAL SEDIMENT CONTROL FENCE (TYP Mal M B4 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. S5 STREAM IMPACTS = 460 Sq.Ft. FILL REMOVAL = 128 Sq.Ft. BUFFER ZONE IIMPACTS = 1880 Sq. Ft. BUFFER ZONE 2 IMPACTS = 1266 Sq.Ft. M 1< CA 20, 30' UFFER BUFR ZONE 2 ZONE 1605.01 High Vim Temporary Silt Fence iii imi 1606.01 Special Sediment Control Fence 1632.03 Rock Inlet Sediment T,ap Type C_ - - - - - - 19 B2 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq. Ft. S3 STREAM IMPACTS = 49I Sq.Ft. FILL REMOVAL = 70 Sq. Ft. BUFFER ZONE IIMPACTS = 2302 Sq. Ft. BUFFER ZONE 2 IMPACTS = l5/3 Sq. Ft. PROJECT REFERENCE NO. I SHEET NO. 30 15 0 30 60 SCALE RECEIVED JAM 10 2012 w 20' BST O Q E I I w z 30' F A - 45'00'00.0 -(LT) R.H. BISHOP, JR., ET AL � FIELD / 643 WATER STREET 0 I H POTlo. +73 1 BELHAVEN, NC 27810 hl O �' / ' BUFFE Z BuF R ZOWE IW R.H. 0V) o -L- Sto 13+1031 A - 0'05' 4/-r (RT) 643 WATER STREET i6 501 PI 20217 30' 1 N ll DB 775 PG 283 D -004'03.6' Q. ���� o ° kn s 15 0116 41 L ' itVJY - - B M # I I PROPOSED 8' HDPE N R.H. BISHOP, JR., ET AL ��N R . ADO' -BL- 9+25 s I (TWWA C906) 643 WATER STREET J BUFFER ZONE 2 IMPACTS 104' LT m EL=8.64' I I I WATER MAIN BY DIRECTIONAL DRILL BELHAVEN, NC 27810n DB 775 PG 283 11 ° 404 WETLAND IMPACTS `� m ++ ml 1 816.27 AC + / E_ __j 1_ — T_ r ENERGY DISSIPA STD. DWG. 876.02 DIFFUSE FLOW THROUGH 15' SPECIAL SEDIMENT CONTROL FENCE (TYP Mal M B4 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. S5 STREAM IMPACTS = 460 Sq.Ft. FILL REMOVAL = 128 Sq.Ft. BUFFER ZONE IIMPACTS = 1880 Sq. Ft. BUFFER ZONE 2 IMPACTS = 1266 Sq.Ft. M 1< CA 20, 30' UFFER BUFR ZONE 2 ZONE 1605.01 High Vim Temporary Silt Fence iii imi 1606.01 Special Sediment Control Fence 1632.03 Rock Inlet Sediment T,ap Type C_ - - - - - - 19 B2 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq. Ft. S3 STREAM IMPACTS = 49I Sq.Ft. FILL REMOVAL = 70 Sq. Ft. BUFFER ZONE IIMPACTS = 2302 Sq. Ft. BUFFER ZONE 2 IMPACTS = l5/3 Sq. Ft. PROJECT REFERENCE NO. I SHEET NO. 30 15 0 30 60 SCALE RECEIVED JAM 10 2012 w 20' BST O BUFFER ZONE I E ISTING 6'P 'I 30' F A - 45'00'00.0 -(LT) R.H. BISHOP, JR., ET AL CULTIVATED FIELD D - 47T27'534' 643 WATER STREET 0 I H POTlo. +73 L - 9.42 -D- T - 497' BELHAVEN, NC 27810 0 15011641 Q R.H. BISHOP, JR., ET AL 816 271 AC CULTIVATED 643 WATER STREET PT I- BELHAVEN, NC 27810 N ll DB 775 PG 283 p, N - - 816.27 AC o ° kn E a n N BUFFER ZONE /IMPACTS N m it J BUFFER ZONE 2 IMPACTS IL_/1 alla 404 WETLAND IMPACTS ENERGY DISSIPA STD. DWG. 876.02 DIFFUSE FLOW THROUGH 15' SPECIAL SEDIMENT CONTROL FENCE (TYP Mal M B4 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. S5 STREAM IMPACTS = 460 Sq.Ft. FILL REMOVAL = 128 Sq.Ft. BUFFER ZONE IIMPACTS = 1880 Sq. Ft. BUFFER ZONE 2 IMPACTS = 1266 Sq.Ft. M 1< CA 20, 30' UFFER BUFR ZONE 2 ZONE 1605.01 High Vim Temporary Silt Fence iii imi 1606.01 Special Sediment Control Fence 1632.03 Rock Inlet Sediment T,ap Type C_ - - - - - - 19 B2 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq. Ft. S3 STREAM IMPACTS = 49I Sq.Ft. FILL REMOVAL = 70 Sq. Ft. BUFFER ZONE IIMPACTS = 2302 Sq. Ft. BUFFER ZONE 2 IMPACTS = l5/3 Sq. Ft. PROJECT REFERENCE NO. I SHEET NO. 30 15 0 30 60 SCALE RECEIVED JAM 10 2012 w +0100 L N O - 1 F35_00 I 75' RT I 30 N/ BUFFER ZONE 2 1 ZONE I ZONE B3 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. S4 STREAM IMPACTS = 427 Sq.Ft. FILL REMOVAL = 77 Sq. Ft. BUFFER ZONE I IMPACTS = 701 Sq. Ft. BUFFER ZONE 2 IMPACTS = 354 Sq. Ft. NOTES: CULTIVATED FIELD 0 15011641 R.H. BISHOP, JR., ET AL 643 WATER STREET BELHAVEN, NC 27810 DB 775 PG 283 816.27 AC (l) B-5202 IS ON THE PANTEGO USGS QUAD MAP AND SHEET NUMBER 9 OF THE SOILS SURVEY OF BEAUFORT COUNTY (2) FIRM PANEL 6688 J. MAP NUMBER 3720668800 J (3) B-5202 IS IN THE TAR-PAMLICO RIVER BASIN HUC CODE 03020/04 EXISTING BRIDGE "I8 WOOD- PILING STRINGERS (4) NO MORATORIUM AS PER TRAVIS WILSON, NCWRC HW/WW ON NbRTHEAST SIDE NOVEMBER 19,2009 CORUGATED STEEL HW/WW ON SOUTHWEST SIDE (5) B-5202, BEAUFORT BRIDGE •60 IS CAMA JURISDICTIONAL AS CONC RAILS, CROSS BEAMS, AND DECK PER STEPHEN LANE, NCDCM DECEMBER 4,2009 O BUFFER ZONE I UNEE2 O 'I -D- P/ Sto 10+350 15011641 30' 20' + A - 45'00'00.0 -(LT) R.H. BISHOP, JR., ET AL D - 47T27'534' 643 WATER STREET I = I H POTlo. +73 L - 9.42 -D- T - 497' BELHAVEN, NC 27810 I R - 12Ll7 DB 83 16i ti1B 816 271 AC CULTIVATED PT I- ll I - - w +0100 L N O - 1 F35_00 I 75' RT I 30 N/ BUFFER ZONE 2 1 ZONE I ZONE B3 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. S4 STREAM IMPACTS = 427 Sq.Ft. FILL REMOVAL = 77 Sq. Ft. BUFFER ZONE I IMPACTS = 701 Sq. Ft. BUFFER ZONE 2 IMPACTS = 354 Sq. Ft. NOTES: CULTIVATED FIELD 0 15011641 R.H. BISHOP, JR., ET AL 643 WATER STREET BELHAVEN, NC 27810 DB 775 PG 283 816.27 AC (l) B-5202 IS ON THE PANTEGO USGS QUAD MAP AND SHEET NUMBER 9 OF THE SOILS SURVEY OF BEAUFORT COUNTY (2) FIRM PANEL 6688 J. MAP NUMBER 3720668800 J (3) B-5202 IS IN THE TAR-PAMLICO RIVER BASIN HUC CODE 03020/04 EXISTING BRIDGE "I8 WOOD- PILING STRINGERS (4) NO MORATORIUM AS PER TRAVIS WILSON, NCWRC HW/WW ON NbRTHEAST SIDE NOVEMBER 19,2009 CORUGATED STEEL HW/WW ON SOUTHWEST SIDE (5) B-5202, BEAUFORT BRIDGE •60 IS CAMA JURISDICTIONAL AS CONC RAILS, CROSS BEAMS, AND DECK PER STEPHEN LANE, NCDCM DECEMBER 4,2009 BUFFER AUTHORIZATION CERTIFICATION FOR BRIDGE REPLACEMENT PROJECTS A riparian buffer authorization is required for bridge replacement activities within the Neuse and Tar - Pamlico River basins per Division of Water Quality (DWQ) regulations 15A NCAC 026.0233 &.0259. The Division of Coastal Management (DCM) through a Memorandum of Understanding with the Division of Water Quality (DWQ) has reviewed your project proposal, determined that the project as proposed complies with the aforementioned regulations, and made a "no practical alternatives" determination per those regulations. Those activities covered by your Coastal Area Management Act (CAMA) permit have received Buffer authorization as long as the project is constructed in a manner that continues to meet all of the conditions listed below. Failure to comply with this Buffer Authorization shall subject the property owner & the party (contractor) performing the construction &/or (and clearing to a civil penalty of up to $2S,000 per day per violation. 1) All stormwater runoff shall be directed as sheetflow through stream buffers at non-erosive velocities, unless otherwise approved by this certification, 2) All riparian buffers impacted by the placement of temporary fill or clearing activities shall be restored to the preconstruction contours and re -vegetated. Maintained buffers shall be permanently re - vegetated with non -woody species by the end of the growing season following completion of construction. For the purpose of this condition, maintained buffer areas are defined as areas within the transportation corridor that will be subject to regular NCDOT maintenance activities including mowing. The area with non -maintained buffers shall be permanently re -vegetated with native woody species before the next growing season following completion of construction. 3) Pursuant to NCAC15A 28 .0233 & .0259, sediment and erosion control devices shall not be placed in Zone 1 of any Neuse or Tar -Pamlico Buffer without prior approval by NCDWQ. At this time, NCDWQ has approved no sediment and erosion control devices in Zone 1, outside of the approved project impacts, anywhere on this project. Moreover, sediment and erosion control devices shall be allowed in Zone 2 of the buffers provided that Zone 1 is not compromised and that discharge is released as diffuse flow. 4) Bridge deck drains shall not discharge directly into the stream. Stormwater shall be directed across the bridge and pre-treated through site -appropriate means (grassed swales, pre -formed scour holes, vegetated buffers, etc.) before entering the stream. Please refer to the most current version of Stormwater Best Management Practices. By your signature below you agree to be held responsible for meeting all of the above listed conditions and verify that all information is complete and accurate. Agent or Appli ant Print? Name Permit Officers Signature Agent 0 Apo p ica P nature Issue Date CAMA GENERAL PERMIT #:_ NCDENR North Carolina Department of Environment and Natural Resources Division of Coastal Management Beverly Eaves Perdue James H. Gregson Governor Director July 6, 2011 NCDOT P.O. Box 1587 Greenville, N.C. 27835 Attn: Jay Johnson Dear Jay: Dee Freeman Secretary Attached is General Permit #57908C to replace an aerial electrical utility line on SR 1763, Havelock, North Carolina and #57907C to replace existing 28' X 105' bridge with a 30' 10" X 124' long bridge and associated infrastructure and re -locate a water utility line on NC 99, approximately 2 miles north of SR 1625, in Pantego, North Carolina. In order to validate this permit, please sign the permit as indicated. Retain the white copy for your files and return the signed yellow and pink copies to us in the enclosed, self-addressed envelope. If the signed permit copies are not returned to this office before the initiation of development, you will be working without authorization and will be subject to a Notice of Violation and subsequent civil penalties. We appreciate your early attention to this matter. Sincerely, Stephen Lane Coastal Management Representative rcb Enclosures 400 Commerce Ave., Morehead City, NC 28557 Phone: 252-808-28081 FAX: 252-247-3330 Internet: www.nccoastalmanagement.net An Equal opportunity 1 Affirmative Action Employer NorthCarohna Naturallrf BUFFER AUTHORIZATION CERTIFICATION FOR BRIDGE REPLACEMENT PROJECTS A riparian buffer authorization is required for bridge replacement activities within the Neuse and Tar - Pamlico River basins per Division of Water Quality (DWQ) regulations 15A NCAC 02B.0233 & .0259. The Division of Coastal Management (DCM) through a Memorandum of Understanding with the Division of Water Quality (DWQ) has reviewed your project proposal, determined that the project as proposed complies with the aforementioned regulations, and made a "no practical alternatives" determination per those regulations. Those activities covered by your Coastal Area Management Act (CAMA) permit have received Buffer authorization as long as the project is constructed in a manner that continues to meet all of the conditions listed below. Failure to comply with this Buffer Authorization shall subject the property owner & the party (contractor) performing the construction &/or land clearing to a civil penalty of up to $25,000 per day per violation. 1) All stormwater runoff shall be directed as sheetflow through stream buffers at non-erosive velocities, unless otherwise approved by this certification. 2) All riparian buffers impacted by the placement of temporary fill or clearing activities shall be restored to the preconstruction contoubs and re -vegetated. Maintained buffers shall be permanently re - vegetated with non -woody species by the end of the growing season following completion of construction. For the purpose of this condition, maintained buffer areas are defined as areas within the transportation corridor that will be subject to regular NCDOT maintenance activities including mowing. The area with non -maintained buffers shall be permanently re -vegetated with native woody species before the next growing season following completion of construction. 3) Pursuant to NCAC15A 2B .0233 & .0259, sediment and erosion control devices shall not be placed in Zone 1 of any Neuse or Tar -Pamlico Buffer without prior approval by NCDWQ. At this time, NCDWQ has approved no sediment and erosion control devices in Zone 1, outside of the approved project impacts, anywhere on this project. Moreover, sediment and erosion control devices shall be allowed in Zone 2 of the buffers provided that Zone 1 is not compromised and that discharge is released as diffuse flow. 4) Bridge deck drains shall not discharge directly into the stream. Stormwater shall be directed across the bridge and pre-treated through site -appropriate means (grassed swales, pre -formed scour holes, vegetated buffers, etc.) before entering the stream. Please refer to the most current version of Stormwoter Best Management Practices. By your signature below you agree to be held responsible for meeting all of the above listed conditions and verify that all information is complete and accurate. Agent or Applicant Printed Name Agent or Applicant Signature c�"-7 Bio CAMA GENERAL PERMIT#: `� Permit Officer's Signature —7—)—)l Issue Date Aoplicant: N Date: % Describe below the HABITAT disturbances for the application. All values should match the name, and units of measurement found in your Habitat code sheet. Habitat Name DISTURB TYPE Choose One TOTAL Sq. Ft. (Applied for. Disturbance total includes any anticipated restoration or ternp impacts) FINAL Sq. Ft. (Anticipated final disturbance. Excludes any restoration and/or temp impact amount) TOTAL Feet (Applied for. Disturbance total includes any anticipated restoration or temp Impacts)_amount FINAL Feet (Anticipated final disturbance. Excludes any restoration and/or temp impact �✓�' Dredge ElFill E]Both [1Other [ -7-�- r 5� r �23 ^�)r� Dredge ❑ Fill [Both ❑ Other ❑ �LJ-25 1 D bredge ❑ Fill ❑ Both [Other ❑ t Dredge [ Fill ❑ Both ❑ Other ❑ ki Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ Dredge ❑ Fill ❑ Both ❑ Other ❑ :o 03.2 � ��� d•.yi.�s � .a :T.r.-nc .. ? .i r,a.i.:--1+ (.'J-r','.V 14) .4 L...J 111 1..�. •. V K ♦ COAST .. :�)j,\•.1 {:=..., .a w„�. :.:J...1 .. ... ..::.1 .-'.15::.'� ICE'EF-1 , APPLICATION for 1ECEMM Major Development Permit JUN 2 0 2011 (last revised 12/27/06) North Carolina d]VI 6 9A*STAL 1. Primary Applicant/ Landowner Information Business Name Project Name (if applicable) North Carolina Department Of Transportation B-5202 Beaufort 18 NC 99 Over Intercepting Canal Beaufort County WBS Element Number 45300 Applicant 1: First Name MI Last Name Jay B. Johnson Applicant 2: First Name MI Last Name If additional applicants, please attach an additional page(s) with names listed. Mailing Address PO Box City State No. 2 - - ext. 1587 Greenville NC ZIP Country Phone No. FAX No. 27835 1587 us 252 - 830 - 3490 ext. 248 252 - 830 - 3341 Street Address (if different from above) City State ZIP Email jbjohnson@ncdot.gov 2. Agent/Contractor Information Business Name Agent/ Contractor 1: First Name MI Last Name Agent/ Contractor 2: First Name MI Last Name Mailing Address PO Box City State ZIP Phone No. 1Phone - - ext. No. 2 - - ext. FAX No. Contractor # Street Address (if different from above) City State ZIP Email <Form continues on back> Form DCM MP -1 (Page 2 of 5) APPLICATION for Major Development Permit 3. Project Location County (can be multiple) Street Address State Rd. # Beaufort 250' (125' East and 125' West) NC 99 Subdivision Name City State Zip Phone No. Lot No. (s) (if many, attach additional page with list) - - ext. I I I I `/&/ a. In which NC river basin is the project located? b. Name of body of water nearest to proposed project 0 Tar -Pamlico Intercepting Canal 4 c. Is the water body identified in (b) above, natural or manmade? d. Name the closest major water body to the proposed pro et sRe. ❑Natural ®Manmade []Unknown Cuckolds Creek �C' e. Is proposed work within city limits or planning jurisdiction? f. If applicable, list the planning jurisdiction or city limit the proposed ❑Yes ®No work falls within. h. None 4. Site Description a. Total length of shoreline on the tract (ft.) b. Size of entire tract (sq.fL) 250' (125' East and 125' West) N/A c. Size of individual lot(s) d. Approximate elevation of tract above NHW (normal high water) or NWL (normal water level) (If many lot sizes, please attach additional page with a list) 11' ❑NHW or ®NWL e. Vegetation on tract Maintained Roadside Grasses f. Man-made features and uses now on tract Bridge g. Identify and describe the existing land uses Jacent to the proposed project site. Agricultural Property h. How does local government zone the tract? i. Is the proposed project consistent with the applicable zoning? N/A (Attach zoning compliance certificate, if applicable) ❑Yes [:]No ®NA j. Is the proposed activity part of an urban waterfront redevelopment proposal? ❑Yes ®No k. Hasa professional archaeological assessment been done for the tract? If yes, attach a copy. ❑Yes []No ®NA If yes, by whom? I. Is the proposed project located in a National Registered Historic District or does it involve a ❑Yes ®No NA National Register listed or eligible property? <Form continues on next page> m. (i) Are there wetlands on the site? 0Yes ®No (ii) Are there coastal wetlands on the site? []Yes ®No (iii) If yes to either (i) or (ii) above, has a delineation been conducted? ®Yes []No (Attach documentation, if available) 70,, Form DCM MP -1 (Page 3 of 5) n. Describe existing wastewater treatment facilities. N/A o. Describe existing drinking water supply source. APPLICATION for Major Development Permit N/A p. Describe existing storm water management or treatment systems. N/A N 6- 5. Activities and Impacts a. Will the project be for commercial, public, or private use? ❑Commercial HPublic/Govemment ❑Private/Community b. Give a brief description of purpose, use, and daily operations of the project when complete. The Existing 105' Long by 28.2' Wide Timber Bridge Will Be Replaced By a Proposed 124'x 30'-10" Cored Slab Bridge. c. Describe the proposed construction methodology, types of construction equipment to be used during construction, the number of each type of equipment and where it is to be stored. The Existing Bridge Will Be Removed and the Proposed Bridge Will Be Constructed. Typical Bridge Construction Equipment Will Be Used, Including,But Not Limited To Tracked Excavators,Dump Trucks, Flat -Bed Trucks,Back-Hoes,And Boom Trucks. d. List all development activities you propose. Bridge Replacement, Pipe Replacement, and Resurfacing. e. Are the proposed activities maintenance of an existing project, new work, or both? Both f. What is the approximate total disturbed land area resulting from the proposed project? 33,300 HSq.Ft or ❑Acres g. Will the proposed project encroach on any public easement, public accessway or other area ❑Yes ❑No HNA that the public has established use of? h. Describe location and type of existing and proposed discharges to waters of the state. N/A i. Will wastewater or stormwater be discharged into a wetland? ❑Yes HNo ❑NA If yes, will this discharged water be of the same salinity as the receiving water? []Yes ❑No [INA j. Is there any mitigation proposed? ❑Yes HNo ❑NA If yes, attach a mitigation proposal. <Form continues on back> 6. Additional Information In addition to this completed application form, (MP -1) the following items below, if applicable, must be submitted in order for the application package to be complete. Items (a) — (f) are always applicable to any major development application. Please consult the application instruction booklet on how to properly prepare the required items below. a. A project narrative. b. An accurate, dated work plat (including plan view and cross-sectional drawings) drawn to scale. Please give the present status of the proposed project. Is any portion already complete? If previously authorized work, clearly indicate on maps, plats, drawings to distinguish between work completed and proposed. c. A site or location map that is sufficiently detailed to guide agency personnel unfamiliar with the area to the site. Form DCM MP -1 (Page 4 of 5) APPLICATION for Major Development Permit d. A copy of the deed (with state application only) or other instrument under which the applicant claims title to the affected properties. e. The appropriate application fee. Check or money order made payable to DENR. f. A list of the names and complete addresses of the adjacent waterfront (riparian) landowners and signed return receipts as proof that such owners have received a copy of the application and plats by certified mail. Such landowners must be advised that they have 30 days in which to submit comments on the proposed project to the Division of Coastal Management. Name R. H. Bishop,Jr. Phone No. SCF Address 643 Water Street Belhaven, NC 27810 Parcel 4656 Q Name 4D0,4f4f% Phone No. Address Name Phone No. Address g. A list of previous state or federal permits issued for work on the project tract. Include permit numbers, permittee, and issuing dates. None h. Signed consultant or agent authorization form, if applicable. i. Wetland delineation, if necessary. j. A signed AEC hazard notice for projects in oceanfront and inlet areas. (Must be signed by property owner) k. A statement of compliance with the N.C. Environmental Policy Act (N.C.G.S. 113A 1-10), if necessary. If the project involves expenditure of public funds or use of public lands, attach a statement documenting compliance with the North Carolina Environmental Policy Act. 7. Certification and Permission to Enter on Land I understand that any permit issued in response to this application will allow only the development described in the application. The project will be subject to the conditions and restrictions contained in the permit. I certify that I am authorized to grant, and do in fact grant permission to representatives of state and federal review agencies to enter on the aforementioned lands in connection with evaluating information related to this permit application and follow-up monitoring of the project. I further certify that the information provided in this application is truthful to the best of my knowledge. Date May 12, 2011 Print Name _Jay B. Johnson Signature _Qv� (�,� 0 Please indicate application attachments pertaining to your proposed p oject. ®DCM MP -2 Excavation and Fill Information ®DCM MP -5 Bridges and Culverts ❑DCM MP -3 Upland Development ❑DCM MP -4 Structures Information Form DCM MP -2 EXCAVATION and FILL (Except for bridges and culverts) Attach this form to Joint Application for CAMA Major Permit, Form DCM MP -1. Be sure to complete all other sections of the Joint Application that relate to this proposed project. Please include all supplemental information. Describe below the purpose of proposed excavation and/or fill activities. All values should be given in feet 1. EXCAVATION ®This section not applicable a. Amount of material to be excavated from below NHW or NWL in b. Type of material to be excavated. cubic yards. c. (i) Does the area to be excavated include coastal wetlands/marsh d. High -ground excavation in cubic yards. (CW), submerged aquatic vegetation (SAV), shell bottom (SB), or other wetlands (WL)? If any boxes are checked, provide the number of square feet affected. ❑CW ❑SAV ❑SB OWL ❑None (ii) Describe the purpose of the excavation in these areas: 2. DISPOSAL OF EXCAVATED MATERIAL ®This section not applicable a. Location of disposal area. b. Dimensions of disposal area. C. (i) Do you claim title to disposal area? d. (i) Will a disposal area be available for future maintenance? ❑Yes ❑No [:]NA ❑Yes ❑No ❑NA (ii) If no, attach a letter granting permission from the owner. (ii) If yes, where? e. (i) Does the disposal area include any coastal wetlands/marsh f. (i) Does the disposal include any area in the water? (CW), submerged aquatic vegetation (SAV), shell bottom (SB), ❑Yes ❑No [INA or other wetlands (WL)? If any boxes are checked, provide the number of square feet affected. (ii) If yes, how much water area is affected? ❑CW ❑SAV ❑SB OWL ❑None (ii) Describe the purpose of disposal in these areas: 3. SHORELINE STABILIZATION ❑This section not applicable (If development is a wood groin, use MP -4 — Structures) Access Other Channel Canal Boat Basin Boat Ramp Rock Groin Rock (excluding (NLW or Breakwater shoreline NWL) stabilization Length Width Avg. Existing Depth NA NA Final Project Depth NA NA 1. EXCAVATION ®This section not applicable a. Amount of material to be excavated from below NHW or NWL in b. Type of material to be excavated. cubic yards. c. (i) Does the area to be excavated include coastal wetlands/marsh d. High -ground excavation in cubic yards. (CW), submerged aquatic vegetation (SAV), shell bottom (SB), or other wetlands (WL)? If any boxes are checked, provide the number of square feet affected. ❑CW ❑SAV ❑SB OWL ❑None (ii) Describe the purpose of the excavation in these areas: 2. DISPOSAL OF EXCAVATED MATERIAL ®This section not applicable a. Location of disposal area. b. Dimensions of disposal area. C. (i) Do you claim title to disposal area? d. (i) Will a disposal area be available for future maintenance? ❑Yes ❑No [:]NA ❑Yes ❑No ❑NA (ii) If no, attach a letter granting permission from the owner. (ii) If yes, where? e. (i) Does the disposal area include any coastal wetlands/marsh f. (i) Does the disposal include any area in the water? (CW), submerged aquatic vegetation (SAV), shell bottom (SB), ❑Yes ❑No [INA or other wetlands (WL)? If any boxes are checked, provide the number of square feet affected. (ii) If yes, how much water area is affected? ❑CW ❑SAV ❑SB OWL ❑None (ii) Describe the purpose of disposal in these areas: 3. SHORELINE STABILIZATION ❑This section not applicable (If development is a wood groin, use MP -4 — Structures) Form DCM MP -2 (Excavation and Fill, Page 2 of 2) a. Type of shoreline stabilization: ®Bulkhead ORiprap ❑Breakwater/Sill ❑Other: c. Average distance waterward of NHW or NWL: 0 e. Type of stabilization material: Granite g. Number of square feet of fill to be placed below water level Bulkhead backfill 50'x 5 = 250 Sq. Ft. Riprap 0 Breakwater/Sill Other i. Source of fill material. RECEIVED b. Length: 250' (125' East And 125' West) I J U IN G U � U ) j Width: 6'-10' i d. Maximum distance waterward of NHW or NV&4 MHD CITY f. (i) Has there been shoreline erosion during preceding 12 months? ❑Yes ®No ❑NA (ii) If yes, state amount of erosion and source of erosion amount information. h. Type of fill material. Granite 4. OTHER FILL ACTIVITIES ®This section not applicable (Excluding Shoreline Stabilization) a. (i) Will fill material be brought to the site? ❑Yes ❑No ❑NA b. (i) Will fill material be placed in coastal wetlands/marsh (CW), If yes, submerged aquatic vegetation (SAV), shell bottom (SB), or (ii) Amount of material to be placed in the water other wetlands (WL)? If any boxes are checked, provide the number of square feet affected. (iii) Dimensions of fill area ❑CW ❑SAV ❑SB (iv) Purpose of fill OWL ❑None (ii) Describe the purpose of the fill in these areas: 5. GENERAL a. How will excavated or fill material be kept on site and erosion b. What type of construction equipment will be used (e.g., dragline, controlled? backhoe, or hydraulic dredge)? Silt Fences and Rip Rap Typical Road and Bridge Construction Equipment C. (i) Will navigational aids be required as a result of the project? d. (i) Will wetlands be crossed in transporting equipment to project ❑Yes ®No ❑NA site? ❑Yes ®No ❑NA (ii) If yes, explain what type and how they will be implemented. (ii) If yes, explain steps that will be taken to avoid or minimize environmental impacts. May 12, 2011 Ap plicant Signature Date B-5202 Beaufort18 NC 99 Over Intercepting Canal Beaufort County WBS Element Number 45300 Project Name Jay B. Johnson plicant Name F0119 ON NP.i BRIDGES and CULVERTS Attach this form to Joint Application for CAMA Major Permit, Form DCM MP -1. Be sure to complete all other sections of the Joint Application that relate to this proposed project. Please include all supplemental information. 1. BRIDGES ❑This section not applicable a. Is the proposed bridge: ❑Commercial ®Public/Government ❑Private/Community c. Type of bridge (construction material): Proposed 21" Cored Slab Bridge e. (i) Will proposed bridge replace an existing bridge? ®Yes ❑No If yes, (ii) Length of existing bridge: 105' (iii) Width of existing bridge: 28.2' (iv) Navigation clearance underneath existing bridge: 11' (v) Will all, or a part of, the existing bridge be removed? (Explain) All of the Existing Bridge will be Removed b. Water body to be crossed by bridge: Intercepting Canal d. Water depth at the proposed crossing at NLW or NWL: 4.9' f, (i) Will proposed bridge replace an existing culvert? ❑Yes ®No If yes, (ii) Length of existing culvert: (iii) Width of existing culvert: (iv) Height of the top of the existing culvert above the NHW or NWL: (v) Will all, or a part of, the existing culvert be removed? (Explain) 9- Length of proposed bridge: 124' h. Width of proposed bridge: 30'-10" i. Will the proposed bridge affect existing water flow? ❑Yes ®No j. Will the proposed bridge affect navigation by reducing or If yes, explain: increasing the existing navigable opening? [--]Yes ®No If yes, explain: k. Navigation clearance underneath proposed bridge: 11' I. Have you contacted the U.S. Coast Guard concerning their approval? [-]Yes ®No If yes, explain: m. Will the proposed bridge cross wetlands containing no navigable n. Height of proposed bridge above wetlands: N/A waters? ❑Yes ®No If yes, explain: 2. CULVERTS ®This section not applicable a- Number of culverts proposed: b. Water body in which the culvert is to be placed: < Form continues on back> Form :)Gti1 iMP-5 (Bridges end Culverts, Page 2 of 4) c. Type of culvert (construction material): d. (i) Will proposed culvert replace an existing bridge? ❑Yes ❑No If yes, (ii) Length of existing bridge: (iii) Width of existing bridge: (iv) Navigation clearance underneath existing bridge: (v) Will all, or a part of, the existing bridge be removed? (Explain) f. Length of proposed culvert: h. Height of the top of the proposed culvert above the NHW or NWL 0' j. Will the proposed culvert affect navigation by reducing or increasing the existing navigable opening? ❑Yes ❑No If yes, explain: MF RECEWED I JUN 2 0 2011 I DCM-MHD CITY e. (i) Will proposed culvert replace an existing culvert? ❑Yes []No If yes, (ii) Length of existing culvert(s): (iii) Width of existing culvert(s): (iv) Height of the top of the existing culvert above the NHW or NWL: (v) Will all, or a part of, the existing culvert be removed? (Explain) 9. Width of proposed culvert: i. Depth of culvert to be buried below existing bottom contour. 1' k. Will the proposed culvert affect existing water flow? ❑Yes ❑No If yes, explain: 3. EXCAVATION and FILL El This section not applicable a C. (i) Will the placement of the proposed bridge or culvert require any excavation below the NHW or NWL? ❑Yes ®No If yes, (ii) Avg. length of area to be excavated: (iii) Avg.. width of area to be excavated: (iv) Avg. depth of area to be excavated: (v) Amount of material to be excavated in cubic yards: (i) Will the placement of the proposed bridge or culvert require any high -ground excavation? ®Yes ❑No If yes, (ii) Avg. length of area to be excavated: 10' East and 8' West (iii) Avg. width of area to be excavated: 10.4' East and 13.4' West (iv) Avg. depth of area to be excavated: 2' (v) Amount of material to be excavated in cubic yards: 15.6 Cubic Yards b. (i) Will the placement of the proposed bridge or culvert require any excavation within coastal wetlandstmarsh (CW), submerged aquatic vegetation (SAV), shell bottom (SB), or other wetlands (WL)? If any boxes are checked, provide the number of square feet affected. ❑CW ❑SAV ❑SB OWL ®None (ii) Describe the purpose of the excavation in these areas: Fq3r--'r OCN`1 !3 -ridges -and Culver- ;a 3 of 4) RECEIVED d. If the placement of the bridge or culvert involves any excavation, please complete the following: (i) Location of the spoil disposal area: Temporary Spoil Area is in the Existing Road i JUN 2 U 1011 (ii) Dimensions of the spoil disposal area: 100' x 200' (iii) Do you claim title to the disposal area? ®Yes 0 N (if no, attach a letter granting rantin permission from the owner.) DCM-MHDCI1y (iv) Will the disposal area be available for future maintenance? ®Yes ❑No (v) Does the disposal area include any coastal wetlands/marsh (CW), submerged aquatic vegetation (SAVs), other wetlands (WL), or shell bottom (SB)? ❑CW ❑SAV OWL OSB ®None If any boxes are checked, give dimensions if different from (ii) above. (vi) Does the disposal area include any area below the NHW or NWL? ? ❑Yes ®No If yes, give dimensions if different from (ii) above. e. (i) Will the placement of the proposed bridge or culvert result in any fill (other than excavated material described in Item d above) to be placed below NHW or NWL? ❑Yes ®No If yes, (ii) Avg. length of area to be filled: (iii) Avg. width of area to be filled: (iv) Purpose of fill: (i) Will the placement of the proposed bridge or culvert result in any fill (other than excavated material described in Item d above) to be placed within coastal wetlands/marsh (CW), submerged aquatic vegetation (SAV), shell bottom (SB), or other wetlands (WL)? If any boxes are checked, provide the number of square feet affected. ❑CW ❑SAV ❑SB OWL ®None (ii) Describe the purpose of the excavation in these areas: g. (i) Will the placement of the proposed bridge or culvert result in any fill (other than excavated material described in Item d above) to be placed on high -ground? ®Yes ❑No If yes, (ii) Avg. length of area to be filled: 300' East 285' West (iii) Avg. width of area to be filled: 10' East 16' West (iv) Purpose of fill: Roadway Shoulders a. Will the proposed project require the relocation of any existing b. Will the proposed project require the construction of any temporary utility lines? ` " 3` I ®Yes ❑No detour structures? ❑Yes ®No If yes, explain: be Relocated By If yes, explain: Directional Bore. If this portion of the proposed project has already received approval from local authorities, please attach a copy of the approval or certification. < Form continues on back> jrlA-5 !3ridrles a d C _inert:>>, png, e ,; of 4) C. Will the proposed project require any work channels? ❑Yes ®No If yes, complete Form DCM-MP-2. e. What type of construction equipment will be used (for example, dragline, backhoe, or hydraulic dredge)? Typical Bridge Construction Equipment g. Will the placement of the proposed bridge or culvert require any shoreline stabilization? ®Yes ❑No If yes, complete form MP -2, Section 3 for Shoreline Stabilization only. May 12,2011 Date B-5202 Beaufort 18 NC 99 Over Intercepting Canal Beaufort County WBS Element Number 45300 Project Name Jay B. Johnson Applicant Name a'.� Applicant Signa e F_ RECEIVED d. How will excavated or fill material be kept on site and erosion controlled? JUN 2 0 2011 Turbidity Curtains and Silt Fences will be used to retain sediment on-site DCM-MHD CITY f. Will wetlands be crossed in transporting equipment to project site? ❑Yes ®No If yes, explain steps that will be taken to avoid or minimize environmental impacts. BEVERLY EAVES PERDUE GOVERNOR „4e STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION May 12, 2011 RECEIVED JUN 2 0 /011 DCM-MHD CITY i EUGENE A. CONTI, JR. SECRETARY WBS Element Number: 45300 County: Beaufort Description: B-5202 Beaufort 18, NC 99 Over Intercepting Canal MEMORANDUM TO: Stephen Lane, NCDCM Field Representative FROM: Jay Johnson Division 2 Environmental Officer SUBJECT: Section .1600 GP Request Division 2 respectfully request a CAMA Section .1600 GP for the Water Line Relocation as shown on the Utility Plans. Your assistance in this matter is greatly appreciated. JBJ/ms MAILING ADDRESS: NC DEPARTMENT OF TRANSPORTATION DIVISION OF HIGHWAYS P.O. Box 1587 GREENVtLLE, NC 27835 TELEPHONE: (252) 695-2044 FAX: (252) 830-3341 WEBSITE: WWW.NCDOT.GOV LOCATION: P.O. Box 1587 GREENVILLE, NC O�0 W A TF9pG Office Use Only: Corps action ID no. DWQ project no. Form Version 1.3 Dec 10 2008 Page 1 of 11 PCN Form —Version 1.3 December 10, 2008 Version Pre -Construction Notification C Form A. Appticant Information 1. Processing 1 a. Type(s) of approval sought from the Corps: ®Section 404 Permit El Section 10 Permit 1 b. Specify Nationwide Permit (NWP) number: 3 or General Permit (GP) number: 1 c. Has the NWP or GP number been verified by the Corps? ❑ Yes ® No 1d. Type(s) of approval sought from the DWQ (check all that apply): ® 401 Water Quality Certification — Regular ❑ Non -404 Jurisdictional General Permit ❑ 401 Water Quality Certification — Express ® Riparian Buffer Authorization 1 e. Is this notification solely for the record because written approval is not required? For the record only for DWQ 401 Certification: ❑ Yes ® No For the record only for Corps Permit: N Yes ❑ No 1f. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? If so, attach the acceptance letter from mitigation bank or in -lieu fee program. ❑ Yes ® No 1 g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1 h below. N Yes ❑ No 1h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? N Yes ❑ No 2. Project Information 2a. Name of project: B-5202 Beaufort 18 Bridge To Bridge Replacement NC 99 Over Intercepting Canal WBS Element Number 45300 2b. County: Beaufort 2c. Nearest municipality / town: Pantego 2d. Subdivision name: N/A 2e. NCDOT only, T.I.P. or state project no: 45299 3. Owner Information 3a. Name(s) on Recorded Deed: North Carolina Department of Transportation 3b. Deed Book and Page No. N/A 3c. Responsible Party (for LLC if applicable): N/A 3d. Street address: 105 Pactolus Highway NC 33 P.O. Box 1587 3e. City, state, zip: Greenville, NC 27835 3f. Telephone no.: 252-830-3490 3g. Fax no.: 252-830-3341 3h. Email address: jbjohnson@ncdot.gov Page 1 of 11 PCN Form —Version 1.3 December 10, 2008 Version 4. Applicant Information (if different from owner) 4a. Applicant is: ❑ Agent ® Other, specify: Division 2 Environmental Officer 4b. Name: Jay B. Johnson 4c. Business name (if applicable): North Carolina Depratment of Transportation DCM-MHD C 4d. Street address: P.O. Box 1587 4e. City, state, zip: Greenville, NC 27835 4f. Telephone no.: 252-830-3490 4g. Fax no.: 252-830-3341 4h. Email address: jbjohnson@ncdot.gov 5. Agent/Consultant Information (if applicable) 5a. Name: N/A 5b. Business name (if applicable): 5c. Street address: 5d. City, state, zip: 5e. Telephone no.: 5f. Fax no.: 5g. Email address: Page 2 of 11 PCN Form — Version 1.3 December 10, 2008 Version B. Project Information and Prior Project History 1. Property Identification 1a. Property identification no. (tax PIN or parcel ID): B-5201 Beaufort 33 NC 99 Over U/T Cuckolds Creek Latitude: N 35.618235 Longitude: - W 1 b. Site coordinates (in decimal degrees): 76.646340 (DD.DDDDDD) (-DD.DDDDDD) 1 c. Property size: N/A acres 2. Surface Waters 2a. Name of nearest body of water (stream, river, etc.) to proposed project: Cuckolds Creek, a Tributary of Pamlico River 2b. Water Quality Classification of nearest receiving water: SC;NSW 2c. River basin: Tar -Pamlico Pamlico 03020104 3. Project Description 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: NC 99 is a paved Primary State Highway. Woodlands and Agriculture dominate the landscape. 3b. List the total estimated acreage of all existing wetlands on the property: 0 Square Feet of 404 Wetland Impacts For The Bridge To Bridge Replacement. 3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 60' This site is part of a longer adjacent stream system 3d. Explain the purpose of the proposed project: Bridge To Bridge Replacement; the existing bridge has deteoriated and needs replacing. 3e. Describe the overall project in detail, including the type of equipment to be used: The Existing 105' Long RC Floor on Timber Pilings Bridge will be replaced with a Proposed 124' Long 21" Cored Slab Bridge. Excavators, Dump Trucks, and Crane Trucks will be used for the Bridge To Bridge Replacement. 4. Jurisdictional Determinations 4a. Have jurisdictional wetland or stream determinations by the Corps or State been requested or obtained for this property / ®Yes El No El Unknown project (including all prior phases) in the past? Comments: 4b. If the Corps made the jurisdictional determination, what type Preliminary El Final of determination was made? 4c. If yes, who delineated the jurisdictional areas? Agency/Consultant Company: Name (if known): Stephen Lane, NCDCM Jay Other. NCDCM and NCDOT Johnson,NCDOT 4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation. December 4, 2009 5. Project History 5a. Have permits or certifications been requested or obtained for ❑ Yes ® No ❑ Unknown this project (including all prior phases) in the past? 5b. If yes, explain in detail according to "help file" instructions. Page 3 of 11 PCN Form — Version 1.3 December 10, 2008 Version 6. Future Project Plans RECEIVED 6a. Is this a phased project? ❑ Yes ® No 6b. If yes, explain. DCM-MHD CITY Page 4 of 11 PCN Form —Version 1.3 December 10, 2008 Version RECEWED JUN 2 0 ?_011 C. Proposed Impacts Inventory 1. Impacts Summary CM-MHDC 1 a. Which sections were completed below for your project (check all that apply): ❑ Wetlands ® Streams - tributaries ® Buffers ❑ Open Waters ❑ Pond Construction 2. Wetland Impacts If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted. 2a. 2b. 2c. 2d. 2e. 2f. Wetland impact Type of jurisdiction number — Type of impact Type of wetland Forested (Corps - 404, 10 Area of impact Permanent (P) or (if known) DWQ — non -404, other) (acres) Temporary W1 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ W2 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ W3 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ W4 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ W5 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ W6 ❑ P ❑ T ❑ Yes ❑ Corps ❑ No ❑ DWQ 2g. Total wetland impacts 0 Sq. Ft. 2h. Comments: 0 Sq. Ft. of 404 Wetland Impacts 3. Stream Impacts If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this question for all stream sites impacted. 3a. 3b. 3c. 3d. 3e. 3f. 3g. Stream impact Type of impact Stream name Perennial Type of jurisdiction Average Impact number - (PER) or (Corps - 404, 10 stream length Permanent (P) or intermittent DWQ — non -404, width (linear Temporary (T) (INT)? other) (feet) feet) S1 ® P ❑ T Proposed Retaining Wall Intercepting Canal ® PER ❑ INT ❑ Corps ® DWQ 105, 125 Linear. Ft. S2 ®P ❑ T Pilings Intercepting Canal ® PER ❑ INT ❑ Corps ® DWQ 105' 52 Sq. Ft. S3 ®P ❑ T Pilings Intercepting Canal ® PER ❑ INT ❑ Corps ® DWQ 105' 52 Sq. Ft. S4 ® P ❑ T Pilings Intercepting Canal ® PER ❑ INT ❑ Corps ® DWQ 105' 52 Sq. Ft. S5 ®P ❑ T Pilings Intercepting Canal ® PER ❑ INT ❑ Corps ® DWQ 105' 52 Sq. Ft. S6 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ 3h. Total stream and tributary impacts 125 Linear Ft. 3i. Comments: 125 Linear Feet of Stream Impacts for retaining Wall 208 Sq. Ft_ for Pilings In Intercepting Canal Page 5 of 11 PCN Form —Version 1.3 December 10, 2008 Version 4. Open Water Impacts If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any her RR�q,,yp1pr of a�.., i � C ♦L...-. :-+J:..:J..�IL. Cil .-11 �� _� _.._a__ C___ _ _a_ _ _ _ i DCM-MHD CITY w.. Open water Name of waterbody Yom. 4a. 4e. impact number — (if applicable) Type of impact Waterbody type RECEIVED ! rea of impact (acres) Permanent (P) or Temporary L!i11 01 ❑P❑T 02 ❑P❑T CITY 03 ❑P❑T rJCU_mHD 04 ❑P❑T 4f. Total open water impacts None 4g. Comments: No Open Water Impacts 5. Pond or Lake Construction If pond or lake construction ro osed, then complete the chart below. 5a. 5b. 5c. 5d. 5e. Pond ID Proposed use or purpose Wetland Impacts (acres) Stream Impacts (feet) Upland number of pond (acres) Flooded Filled Excavated Flooded Filled Excavated Flooded P1 P2 5f. Total None 5g. Comments: None 5h. Is a dam high hazard permit required? ❑ Yes ❑ No If yes, permit ID no: 5i. Expected pond surface area (acres): 5j. Size of pond watershed (acres): 5k- Method of construction. - 6. Buffer Impacts (for DWQ) If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. 6a. ❑ Neuse ® Tar -Pamlico ❑ Other: None Project is in which protected basin? ❑ Catawba ❑ Randleman 6b. 6c. 6d. 6e. 6f. 6g. Buffer impact number — Reason Buffer Zone 1 impact Zone 2 impact Permanent (P) or for Stream name mitigation (square feet) (square feet) Temporary impact required? B1 ®P ❑ T Fill Intercepting Canal ® Nos 510 Sq. Ft. 320 Sq. Ft. B2 ® P ❑ T Fill Intercepting canal ® Nos 2302 Sq. Ft. 1513 Sq. Ft. B3 ®P ❑ T Fill Intercepting Canal ® Nos 557 Sq. Ft. 354 Sq. Ft. 6h. Total buffer impacts 6i. Comments: See Page 6-A For Total Buffer Impacts Page 6 of 11 PCN Form —Version 1.3 December 10, 2008 Version REMVED JUN 2 0 2011 4. Open Water Impacts If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any otheP60WWW W 1 the U.S. then individually list all open water impacts below. 4a. 4b. 4c. 4d. 4e. Open water Name of waterbody impact number - (if applicable) Type of impact Waterbody type Area of impact (acres) Permanent (P) or Temporary 01 ❑P❑T 02 ❑P❑T 03 ❑P❑T 04 ❑P❑T 4f. Total open water impacts None 4g. Comments: 5. Pond or Lake Construction If pond or lake construction proposed, then complete the chart below. 5a. 5b. 5c. 5d. 5e. Wetland Impacts (acres) Stream Impacts (feet) Upland Pond ID Proposed use or purpose (acres) number of pond Flooded Filled Excavated Flooded Filled Excavated Flooded P1 P2 511 Total None 5g. Comments: None 5h. Is a dam high hazard permit required? ❑ Yes ❑ No If yes, permit ID no: 5i. Expected pond surface area (acres): 5j. Size of pond watershed (acres): 5k. Method of construction: 6. Buffer Impacts (for DWQ) If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts below. If any impacts require mitigation, then you MUST fill out Section D of this form. 6a. ❑ Neuse ® Tar -Pamlico ❑ Other: None Project is in which protected basin? ❑ Catawba ❑ Randleman 6b. 6c. 6d. 6e. 6f. 6g. Buffer impact number - Reason Buffer Zone 1 impact Zone 2 impact Permanent (P) or for Stream name mitigation (square feet) (square feet) Temporary impact B1 ®P ❑ T B 4 Fill Intercepting Canal -required? ® Nos 501 Sq. Ft. 346 Sq. Ft. B2 ❑P❑T El Yes ❑ No B3 ❑P❑T El Yes ❑ No 6h. Total buffer impacts 3870Sq. Ft. 2533 Sq. Ft. 6i. Comments: 0.09 Acres of Buffer Zone 1 Impacts and 0.06 Acres of Buffer 2 Impacts Page I of 6 PCN Form - Version 1.3 December 10, 2008 Version fRECEIVED JUN 2 0 2011 D. Impact Justification and Mitigation 1. Avoidance and Minimization DCM-MHD CITY 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project. There are No 404 Wetland Impacts for this Project and No Coastal Wetland Impacts; However, There are 3870 Square Feet of Buffer Zone 1 Impacts and 2533 Sq. Ft. of Buffer Zone 2 Impacts due to the installation of a Longer Bridge to Replace the Existing Bridge. The Wetland Impacts have been minimized to the greatest extent feasible. lb- Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. Use of existing roadway to operate construction equipment; no equipment will enter wetlands. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? ❑ Yes ® No 2b. If yes, mitigation is required by (check all that apply): ❑ DWQ ❑ Corps 2c. If yes, which mitigation option will be used for this project? ❑ Mitigation bank Payment to in -lieu fee program ❑ Permittee Responsible Mitigation 3. Complete if Using a Mitigation Bank 3a. Name of Mitigation Bank: 3b. Credits Purchased (attach receipt and letter) Type Quantity 3c. Comments: 4. Complete if Making a Payment to In -lieu Fee Program 4a_ Approval letter from in -lieu fee program is attached. ❑ Yes 4b. Stream mitigation requested: linear feet 4c. If using stream mitigation, stream temperature: ❑ warm ❑ cool ❑cold 4d. Buffer mitigation requested (DWQ only): square feet 4e. Riparian wetland mitigation requested: acres 4f. Non -riparian wetland mitigation requested: acres 4g. Coastal (tidal) wetland mitigation requested: acres 4h. Comments: 5. Complete if Using a Permittee Responsible Mitigation Plan 5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan. Page 7 of 11 PCN Form — Version 1.3 December 10, 2008 Version CEIVED JUN 2 0 _7011 6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ 6a. Will the project result in an impact within a protected riparian buffer that requires ❑ Yes ® No buffer mitigation? 6b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the amount of mitigation required. 6c. 6d. 6e. Zone Reason for impact Total impact Multiplier Required mitigation (square feet) (square feet) Zone 1 3 (2 for Catawba) Zone 2 1.5 6f. Total buffer mitigation required: None 6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank, permittee responsible riparian buffer restoration, payment into an approved in -lieu fee fund). N/A 6h. Comments: Page 8 of 11 PCN Form — Version 1.3 December 10, 2008 Version JUN 2 0 2011 E. Stormwater Management and Diffuse Flow Plan (required by DWQ) DCM-MHD CITY 1. Diffuse Flow Plan 1 a. Does the project include or is it adjacent to protected riparian buffers identified ® Yes ❑ No within one of the NC Riparian Buffer Protection Rules? 1 b. If yes, then is a diffuse flow plan included? If no, explain why. Comments: Storm Water will diffuse flow through vegetated uplands before entering ® Yes ❑ No wetlands. There are No Weep Holes on the Proposed Bridge, and stormwater is treated at the outlet pipe at Station 14+20 with Rock Inlet Sediment traps, Type A. Stormwater will filter and diffuse flow through Special Sediment Control Fence. 2. Stormwater Management Plan 2a. What is the overall percent imperviousness of this project? N/A Roadway/Bridge Project % 2b. Does this project require a Stormwater Management Plan? ® Yes ❑ No 2c. If this project DOES NOT require a Stormwater Management Plan, explain why: 2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan: Storm Water will diffuse flow through vegetated uplands before entering wetlands. there are no Weep Holes on the Proposed Bridge, and stormwater is treated at the outlet pipe at Station 14+20 with Rock Inlet Sediment traps, Type A. Stormwater will filter and diffuse flow through Special Sediment Control Fence. ❑ Certified Local Government 2e. Who will be responsible for the review of the Stormwater Management Plan? ❑ DWQ Stormwater Program ® DWQ 401 Unit 3. Certified Local Government Stormwater Review 3a. In which local government's jurisdiction is this project? N/A ❑ Phase II 3b. Which of the following locally -implemented stormwater management programs ❑ NSW ❑ USMP apply (check all that apply): ❑ Water Supply Watershed ❑ Other: N/A 3c. Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ® No attached? 4. DWQ Stormwater Program Review ® Coastal counties ❑ HQW 4a. Which of the following state -implemented stormwater management programs apply ❑ ORW (check all that apply): ❑ Session Law 2006-246 ® Other. NPDES Permit 4b. Has the approved Stormwater Management Plan with proof of approval been attached? ❑ Yes ® No 5. DWQ 401 Unit Stormwater Review 5a. Does the Stormwater Management Plan meet the appropriate requirements? ❑ Yes ❑ No Page 9 of 11 PCN Form — Version 1.3 December 10, 2008 Version 5b. Have all of the 401 Unit submittal requirements been met? ❑ Yes ❑ No F. Supplementary Information 1. Environmental Documentation (DWQ Requirement) 1 a. Does the project involve an expenditure of public (federal/state/local) funds or the ® Yes ❑ No use of public (federal/state) land? 1 b. If you answered "yes" to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State ❑ Yes ® No (North Carolina) Environmental Policy Act (NEPA/SEPA)? 1c. If you answered "yes" to the above, has the document review been finalized by the State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval letter.) ❑ Yes ❑ No Comments: 2. Violations (DWQ Requirement) 2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), DWQ Surface Water or Wetland Standards, ❑ Yes ® No or Riparian Buffer Rules (15A NCAC 2B .0200)? 2b. Is this an after -the -fact permit application? ❑ Yes ® No 2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s): 3. Cumulative Impacts (DWQ Requirement) 3a. Will this project (based on past and reasonably anticipated future impacts) result in ❑ Yes ® No additional development, which could impact nearby downstream water quality? 3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the most recent DWQ policy. If you answered "no," provide a short narrative description. 4. Sewage Disposal (DWQ Requirement) 4a. Clearly detail the ultimate treatment methods and disposition (non -discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility. N/A Page 10 of 11 PCN Form — Version 1.3 December 10, 2008 Version RECEIVED 11 IN 9 a x(111 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or DCM-MHD El Yes es ® No habitat? 5b. Have you checked with the USFWS concerning Endangered Species Act El Yes No impacts? 5c. If yes, indicate the USFWS Field Office you have contacted. ❑ Raleigh ❑ Asheville 5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? Mr.Travis Wilson, NCWRC 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes ® No 6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat? Mr. Travis Wilson, NCWRC 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation ❑ Yes ® No status (e.g., National Historic Trust designation or properties significant in North Carolina history and archaeology)? 7b. What data sources did you use to determine whether your site would impact historic or archeological resources? NCDOT HEU Historic Architecture and Archaeology 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA -designated 100 -year floodplain? —TE —Yes ❑ No 8b_ If yes, explain how project meets FEMA requirements: Bridge designed to no -rise standards 8c. What source(s) did you use to make the floodplain determination? FEMA FIRM Maps Jay B. Johnson May 12, 2011 Applicant/Agent's Printed Name Appli t/ enf Signature Date (Agent's signature is val" o ly if a rization letter from the applicant is rovid Page 11 of 11 PCN Form — Version 1.3 December 10, 2008 Version NO SURVEY REQUIRED FORM PROJECT INFORMATION Project Tracking No. (internal Use) 11-03-0043 71 Project No: B-5202 County: Beaufort WBS No: 45300.1.1 Document: PCE C� F.A. No: Funding: State ® Fede crT Federal (USACE) Permit ® Yes ❑ No Permit Nationwide Required? Type: Project Description: Replace Bridge No. 18 on NC 99 over unnamed canal. Design plans show the bridge will be replaced in-place with an off site detour. Area of Potential Effects (A.P.E.) is 18 meters (60 ft.) wide and 305 meters (1,000 feet) long. SUMMARY OF CULTURAL RESOURCES REVIEW Brief description of review activities, results of review, and conclusions: Review included examination of aerial photograph, topographic map, soil survey, and listings of previously recorded sites, previous archaeological surveys, and previous environmental reviews at the Office of State Archaeology. Aerial photograph shows the project area is ditched agricultural fields in all four quadrants. There is a structure in the southwest quadrant. The unnamed ditch appears to have been artificially straightened. Topographic map (Pantego, N.C.) shows extremely flat landforms in all quadrants, and poorly drained soil in the northeast quadrant. Soil survey shows the soil next to the bridge is very poorly drained Arapahoe fine sandy loam. There are no previously recorded archaeological sites nearby, and the A.P.E. has not been previously surveyed for archaeological sites. The A.P.E. has not been part of any projects that have been through environmental review. Brief Explanation of why the available information provides a reliable basis for reasonably predicting that there are no unidentiTed historic properties in the APE: The review indicates the A.P.E. has little potential for archaeological sites because it is surrounded by poorly drained soil. SUPPORT DOCUMENTATION ®Map(s), ❑Previous Survey Info, ❑Photos, ❑Correspondence, ❑Notes FINDING BY NCDOT CULTURAL RESOURCES PROFESSIONAL NO SURVEY REQUIRED ®Archaeology ❑Historic Architecture Caleb Smith 4/8/2011 NCDOT Cultural Resources Specialist Date "No Survey Required" form for Minor Transportation Projects as Qualified in the 2007 Programmatic Agreement. NCDOT Archaeology & Historic Architecture Groups PANTEGO QUADRANGLE NORTH C � AROLINA BEAUFORT CO. 7.5 MINUTE SERIES (TOPOGRAPHIC) e1;o SW/4 BELHAVEN 15' QUADRANGLE "e X350 3 PLYMOUTH 2/ M!. 76°37'30" 349 40' 51 2 700 000 FEET PUNOO 1.5 Ml. - - _ _ 35037'30" 99 ne 690 000 - 11x 1r FEET 3843 SOP _. 3942 o • !2 • a a ' as mar • / j x 7 f X o _ 3941 60 ' 9 C Q .o X Xll , 0 1� i 19 • 10 /. \ 3940 -- — .`.'./ /• `i, x/3a°'i:may.` � x// 99 >Z g =r `�•. �/' yam\ . j 1 • _ ' S\_ :i �� \ s , J�(� ° I 1 3939 1621 • t _ _ -. R/° y — ..� o /35 �7�•ii �fh! :• 'e —_____ aa)1 `- to ` Ruin 170p RO4o G JIG---�•�• �.__ �1— l r ° � - / 1700 • A . / / ° L _ \ � _ \ � -- _— — x �. 7. 3838 1705 ° - -•-- =- -- - 1 — =- _- -- , fr NO SURVEY REQUIRED FORM PROJECT INFORMATION Project No.- B-5202 WBS No: 45300.0.0 F. A. No: BRSTP-0099(9) Federal (USACE) Permit Required? Project Description: Project Tracking No. (Internal Use) 11-03-0043 County: 1/�;Pc�f ciL�� Documen Funding. t�t, State ® Federal SIT ® Yes ❑ No Permit Type: PNWP3 Replace Bridge No. 18 on NC 99 over unnamed channel. SUMMARY OF CULTURAL RESOURCES REVIEW Brief description of review activities, results of review, and conclusions: Review of HPO quad maps, relevant background reports, historic designations roster, and indexes was undertaken on March 30, 2011. Based on this review, there were no existing NR, SL, LD, DE, or SS properties in the Area of Potential Effects Beaufort County GIS mapping including aerial photography and tax information revealed no structures more than 50 years old exists within the APE. Brief Explanation of why the available information provides a reliable basis for reasonably predicting that there are no unidentified historic properties in the APE: There are no structures more than 50 years old within the APE. Using HPO GIS website and Google Street view, and the Beaufort County Tax Parcel Data provides reliable information regarding the structures in the APE. These combined utilities are considered valid for the purposes of determining the likelihood of historic resources being present. SUPPORT DOCUMENTATION See attached: Maps FINDING BY NCDOT CULTURAL RESOURCES PROFESSIONAL NO SURVEY REQUIRED 313o(�t� NCDOT Culturawesouk4s Specialist "No Survey Required"form for Minor Transportation Projects as Qualified in the 11X17 Programmatic Agreement. NCDOT Archaeology & Historic Architecture Groups Date HPO GIS e, Y �' �✓ frf kt 11 , J _ �04 Asa �r PTS 31G} ILS 1.i Copydght 2010 E30. Al rights resemd. Wed WOO 2011 03:50:07 PM (3 Irk y o ridge No 18 x7 0 .101 e, Y �' �✓ frf kt 11 , J _ �04 Asa �r PTS 31G} ILS 1.i Copydght 2010 E30. Al rights resemd. Wed WOO 2011 03:50:07 PM (3 Irk y o ridge No 18 x7 0 0 U STATE OF NORTH CAROLINA DI'VISION OF HIGHWAYS BEA UFORT COUNTY LOCATION: NC 99, BRIDGE N0.18 OVER A CANAL TYPE OF WORK: BRIDGE REPLACEMENT, GUARDRAIL, PAVING, GRADING AND DRAINAGE VICINFT A Sm Sled PA fpr !roti of Sws I 1 l � ) 1 ------------ ------------------------- ----------------- ------ d lA'DIUULCS ENGDZEI� &WSMN DP RYC"AYS GRAPHIC SCALES DIVISION OF HIGHWAYS STATS w NORM CAROLINA SQ 50 1 I)/1 N.,.1 G ..... J.r..r W...• Ill.. NC DAM PROJECT LENGTH PLANS LENGTH ROADWAY TLP PROJECT 8-5202 - 0.137 MLLE cew� So 24.-.i .r4 50 ,Qo LENGTH STRUCTURE TIP PROJECT B-5202 = 0.011 MILE MLGN7 OP IYAY A17& DWAYNE H`�O" W Q PROFILE IMOR120NTAl)EhfGjmuR TOTAL LFNG7H OF TIP PROJECT B -S202 = 0.161 MLLEROAOWAV DESIGN �M..� ,p 7q 1BTTINC 61Y$ LANG (ONES RE Beaufort 18 B-5202.txt From: Lane, Stephen Sent: Friday, December 04, 2009 9:06 AM To: Sutton, Michael w Subject: RE: Beaufort 39 B-4025 Hi Mike, I have visited the following sites and made the following jurisdictional determinations: Beaufort County Bridge 18 (B-5202) on NC99 over Intercepting Canal - Jurisdictional Beaufort County Bridge 39 (B-4025) on SR1925 over Broomfield swamp Canal - Jurisdictional Beaufort county Bridge 60 (B-5200) on NC33 over Blounts Creek - Jurisdictional Craven county Bridge 10 (B-4086) on SR1111 over Brice Creek - Jurisdictional I also plan to visit the remaining sites you sent me for determinations next week if we have some normal weather patterns then and will send you an email on what I find out. Thanks, Stephen ­---original Message ----- From: Sutton, Michael w Sent: Thursday, December 03, 2009 11:20 AM To: Lane, Stephen Cc: Caldwell, Betty A; Johnson, Jay B; Jones, Larry L Subject: Beaufort 39 B-4025 Good Morning Lady and Gentlemen... Beaufort 39,B-4025, SR 1925,Idalia Road over Broomfield Swamp canal is up for replacement. we request a LAMA Jurisdictional call as soon as possible. Attached are maps for your use.Many Thanks ... mike Email correspondence to and from this sender is subject to the N.C. Public Records Law and may be disclosed to third parties. Page 1 Sutton,'Michael W From: Wilson, Travis W. 1ZECEIVBD Sent: Thursday, November 19, 2009 12:52 PM To: Sutton, Michael W JUN 2 0 Subject: RE: Division 2 Bridges 2011 f DcAl.M ID CITY Mike, I think this covers all the bridge replacements projects you have requested comments for, however if I have left off anything let me know. B-5200: This crossing of Blount's Creek should have an anadromous fish moratorium of Feb 15 to June 15. 3-5201: No concern B-5202: No Concern B-5203: No Concern B-5204: No Concern B-5205: No Concern B-4234: No concern B-4236: No Concern If you have any more questions let me know. Email correspondence to and from this sender is subject to the N.C. Public Records Law and may be disclosed to third parties. 1 IAomlrq S4 "02 1 rArncco \ iszs KK.,^ wnd ' I ,s icze ' YICINRY MAP NOT TO swJD STATE OF NORTH][ CAROLINA DIVISION OF HIGHWAYS BEAUFORT COUNTY LOCATION: NC 99, BRIDGE NO. 18 OVER A CANAL TYPE OF WORK WATER MAIN RELOCATION UTILITY OWNER: BEAUFORT COUNTY WATER See Steil t -A For Index of Sheets " ' I :GIN TIP PROJECT 6-5202- - STATION I1+20.00 f ' J � TO SR ASPS ------- — — F GRAPHIC SCALES SO Z5 0 50 140 PLANS 30 ,�3 4 30 140 PROFILE (HORIZONTAL) PROJECT LENGTH LENGTH ROADWAY TIP PROJECT B-5202 = 0140 MILE LENGTH STRUCTURE TIP PROJECT B-5202 = 0.027 MILS TOTAL LENGTH OF TIP PROJECT B—S202 = OJ67 MILE P7Tp2w In ft Nfks Wi DIVISION OF HIGHWAYS J704 N..A 0...,, Sn.rt 0,—.49t., NC 2185 RMW OF WAY DAM 2bA H. AWGOOD +.w� Jom® IBITTNG ZNTB LANG JONES OCTOBER 2011 RECEIVED JUN 3 0 2011 DCM-MHD CITY D TIP PROJECT B-5202 — creTlnAt gn+ranm TO SR r69 iIr= DESIGN ENGINEER DIVISION OF HIGHWAYS STATE OF NORTH CAROLINA UTILITY CONSTRUCTION LL rE RAM WN TO COFOIY TO TIE FTxln A Mi. PrasuE C $ MO. �0. OILTIE FNN fS4 SIIE BIPSI 01406Oa. mo WTEJWL OEAOl1TION PE N W NSF (D APP WD M POTABLE NATER (ALI 2 THE PBOP05kD rATEA LK FF OCATIRI DOES Oim.TO ND o y pFN L PFIUTS AfE NO ORM(T QIEAM PI SYO IJ�A.7i a - 009 413 (R!) OI % ' R - 668000' 8A f RK BCS A Cf K h I �IM��OLryIC t1�OT � � 1 Z MO^.QBEIJ /S 1� TNT' nlb'E i.IfAL y ar I I OWAAOL yY-� v [IIOP POlI wry( - aAm.iLD sUy J im 1>fYO'IfroR� PROFILE ALONG PROPOSED WATER MAIN -WM- 10 11 12 13 1 14 15 16 f A6Awm � 50 25 4 50 1Q0 GRAPHIC SCALE &IL F--111 Q. v`1 --------------N }IDPH aDIP T,.,"—_� TL.tt CA--__-_____- ■ JUN 3 0 2011 DCM-MHD CITY a (D RJl BmA1��. Elf K (ALI Oim.TO ND o y f A6Awm � 50 25 4 50 1Q0 GRAPHIC SCALE &IL F--111 Q. v`1 --------------N }IDPH aDIP T,.,"—_� TL.tt CA--__-_____- ■ JUN 3 0 2011 DCM-MHD CITY F� C Z' OPERRTI WT 0 -RING O -RI �+I -RING 0 -RI I I i -RING I' viv ...t.. L.il ..[.., TYPICAL RESILIENT MECHANCIAL JOINT GATE VALVE DETAIL M6 UTILITY CONSTRUCTION DETAIL SHEET O O .x� nen Pl000lEc 11 U It T A�eRF POa.1 �T T- 3 kyr �x ..1- NW E n i Anastu T wYaVa— By OR R YN.K eOx I TMwED N454j, , le a lint uao I • [I awc 1- t. a�at.a m� ER -i T lRln I I Naw PLAN VIEV���1 ��•-"•� � OOf�WY a.ixml� tw . BOTTOM SECTION L 1�, �,avE aox wrm arl_ tw a n n SECTTON VIFVAIT. a1 wlro a --.n•—{ 2 Y >YLL x ornml a atweo ansix v men TOP sEOTION x navacven to nc u. n. a. Y w.¢ ao TYPICAL VALVE BOX TYPICAL VALVE BOX hn � FORTS F j,� MIE6• 1. FNBEOQIT .1—AL ..T 6E CLN56 I IND. 61 OR W. 1. Va9m 6TRE I6 TTPIGALLT U6E01. a 2. EMBEgFNT MRTERIAL SHALL BE COMPACTEp TO A KIN— RSx ST— flACTU1 O—ITY FOR CLASS 1 NATERM. 3. .1ANOAfO REDOING S1NLL BE VT ILIZEO FOR ALL CASE6 YIIFIE TRENOI B ORS ARE —TA C ULE TO SOIL TYPE. OR NO—K —TIONS. TYPICAL BEDDING FOR FLEXIBLE & SEMI-RIGID PIPE NTS PJPE O.O. w TO ISB P.s. I. A IF AESTAAAtWO JOINT 1 -I? X PfPE O.O. OYER O(P II PJPE .aIfMTS TW. 1 �•YB P. s. J. lw P.s.f. CwdArTE MASENENT ALL RESTRAINED .q(NT MEC1MVfGY. aRN.e.O F(A4 REACTION fLYit ING OR F(>T(NG. BK%!AO ~W OIP sf1E As IT— RS FS PERP RRNO SPECS PER PLAMs jj IRE rT a mosso RrNc l ' YELOEO ro PIPE � ANCHOR RING DIMENSIONS eEaRrNc aREa arnrxsr r)awa sramofn NJ W0f5�1//a!E M5T QMO rY0 GASKETS w MpNIRAL PIPE SIZE 0.0. OF RINGS THTCMTE56 EOWL ) s. i. EXTENDED BQ IS PER NJ A• - ]E' PIPE 0.0. • 6' t/2' F(TT(AG MNa.F'ACTLRER 30' i — PIPE 0.0. B• Gl• TYPICAL DIP TO HDPE TRANSITION DETAIL WITH THRUST COLLAR Nrs -'UNITED STATE4j4,?__Q,8- • Sender: Please print your name, address, and ZIP_+_,r7-_t'h"is box N.C. DEPT. OF TRANSPORTATION PO BOX 1587 GREENVILLE, NC 27835 0 t g3 --4 Z),J' ■ Complete items 1, 2, and 3. Also complete Rem 4 if Restricted Delivery is desired. ■ Print your name and address on the reverse , so that we can return the card to you. ■ Attach this card to the back of the mailpiece, or on the front if space permits. 1. Article Addressed to: . �f •�l� hD� ��K . E D'')�, 1 %V C A. Si gq re Agent // 9 X Addressee Zelve�jv, ( Pripted Name) C. Date of Delivery D. Is delivery address Aerent from item 1? ❑ Yes If YES, enter delivery address below: ❑ No 3.Se Ice Type ZCertifled Mail ❑ Express Mail ❑ Registered ❑ Return Receipt for Merchandise ❑ Insured Mail ❑ C.O.D. —278)0 f 4. Restricted Delivery? (Extra Fee) ❑ Yes 2. Article Number 7010 3090 0001, 0741 9583 (Transfer from service laben PS Form 3811, February 2004 Domestic Return Receipt 102595-02-M-1540 ^, O 00 C1 � C x� n � o p - P A N£ G 0 -----_--Conol - S W A V P 626 Morning Sf°r ` Ch. \ 4 P�202 \ Swindal 99 \ 1625 2 PANTEGO '. 626 KK' m ` \ 2 Yvilldrison 6 264 QVO W ' / ft �J 1624 VICINITY MAP (NOT TO SCALE) See Sheet 1-A For Index of Sheets BEGIN TIP PROJECT B-5202 —L— STATION 11+20.00 TO SR 1625 -- NC mw 99 E— 20' BST GRAPHIC SCALES 50 25 0 50 100 PLANS 50 25 0 5 11 0 100 PROFILE (HORIZONTAL) 10 5 0 10 20 STATE OF NORTH CAROLINA DIVISION OF HIGHWAYS H WA YS BEA UFOR T COUNTY LOCA TION. KC 99, BRIDGE NO. 18 OVER A CANAL TYPE OF WORK: BRIDGE REPLACEMENT, GUARDRAIL, PAVINiG, GRADING AND DRAINAGE t I I JB BEGIN APPROACH I _ —L— STATION 14+84.08 I I I PROJECT LENGTH LENGTH ROADWAY TIP PROJECT B-5202 = 0.140 MILE LENGTH STRUCTURE TIP PROJECT 8-5202 = 0.027 MILE TOTAL LENGTH OF TIP PROJECT B-5202 = 0.167 MILE END APPROACH SLAB —L— STATION I6+28.08 Prepgred In VL Office of: DIVISION OF HIGHWAYS 1704 North Gruver Street Green°USe, NC 2783S -m— sr --C4a RIGHT OF WAY DATE: Q AY H.ALLIGOOD__ LETTING DATE: PflWBCT MVGDQ= LANG JONES rnO = n9s= Gramm RECEIVED JUN 2 0 2011 i DCM-MU j crrr 1 END TIP PROJECT B-5202 —L— STATION 20+00.00 NC Wh 99 - — — — n-85r— RECEIVED 5r izz"A A[J"wa —.-- ROADWAY DESIGN ENGIAZER TO SR 1629 sw�v• STATE OF NORTH CAROLINA Op VBORrN °s o s 0 `gyp op Pd Note: Not to Scale *S. U.E. = Subsurface Utility Engineering S'J[`A7[°lE OF NORTH CA1E8OIl.dNA DIVISION OF HIGHWAYS CONVENTIONAL PLAN SHEET SYMBOLS KOJECT REFERENCE NO. I SHEET NO. WATER: BOUNDARIES AND PROPERTY- Water Manhole O State Line RAILROADS- Water Meter o — --- - County Line Standard Gauge csr rRa,-s�aa� Water Valve Township Line - RR Signal Milepost o M EXISTING STRUCTURES.' Water Hydrant -0 City Line —_ — 0 Swfrcm MAJOR: Recorded WG Water Line Switch Reservation Line — — RR Abandoned — — -- — Bridge, Tunnel or Box Culvert c -c I Designated USG Water Line (S.U.E,`) - - - -•- - - - Property Line RR Dismantled - - Bridge Wing Wall, Head Wall and End Wall - c-1 Above Ground Water Line ^/c ■°,er Existing Iron Pin o EG RIGHT OF WAY: MINOR: Property Corner Baseline Control Point Head and End Wall TV: Property Monument El EN Existing Right of Way Marker 8 g Y Pipe Culvert TV Satellite Dish CC Parcel/Sequence Number @9 Existing Ri ht of Wa Line g Y - Footbridge �---------< TV Pedestal Existing Fence Line -XXX- Proposed Ri ht of WaY Line P 9 Drainage Box: Catch Basin, DI or JB ❑EB TV Tower Proposed Woven Wire Fence - e--- Proposed d Ri ht of Way Line with p 9 Y Paved Ditch Gutter ----- LbG TV Cable Hand Hole Proposed Chain Link Fence EJ Iron Pin and Cap Marker Storm Sewer Manhole OO Recorded LYG TV Cable Proposed Barbed Wire Fence Proposed Right of Way Line with Concrete or Granite Marker --%)- Storm Sewer . Designated UG TV Cable (S.U.E.) - Existing Wetland Boundary - - - -Ke- - - - Existing Control of Access Recorded USG Fiber Optic Cable ° Proposed Wetland Boundary Proposed Control of Access ti' (1, �— UTILITIES. Designated lJG Fiber Optic Cable (S.U.E.') - - - -* °- - - na Existing Endangered Animal Boundary Existing Easement Line —E POWER: Existing Endangered Plant Boundary Proposed Temporary Construction Easement- E Existing Power Pole GAS: BUILDINGS AND OTHER CULTURE.' Proposed Temporary Drainage Easement— Toe Proposed Power Pole d Gas Valve 0 Gas Pump Vent or USG Tank Cap O Proposed Permanent Drainage Easement — PDE Existing Joint Use Pole Proposed -l- Gas Meter Sign O Proposed Permanent Utility Easement Pue Joint Use Pole Recorded lYG Gas Line ° Well o " Proposed Temporary Utility Easement TUE Power Manhole © Designated WG Gas Line (S.U.E,') - - - -°- - - Proposed Permanent Easement with Power Line Tower ® Above Ground Gas Line Small Mine Iron Pin and Cap Marker + Power Transformer (� Foundation 0 ROADS AND RELATED FEATURES USG Power Cable Hand Hole E2 SANITARY SEWER: Area Outline J ExistingEde of Pavement -— ----- g H -Frame Pole �• Sanitary Sewer Manhole OO Cemetery Existing Curb ----- Recorded USG Power Line Sanitary Sewer Cleanout O Building Proposed Slope Stakes Cut - - - - - - Designated UkG Power Line (S.U.E.') - - - -P- - - - USG Sanitary Sewer Line u School D Proposed Slope Stakes Fill - - - F - - - Above Ground Sanitary Sewer Seer Church Proposed Wheel Chair Ramp © TELEPHONE: ine Recorded SS Forced Main Line— Dom Dom Listing Metal Guardrail Existing Telephone Pole to Designated SS Forced Main Line (S.U.E.') - - -- HYDROLOGY.• Proposed Guardrail T T Proposed Telephone Pole -O- C Stream or Body of Water Existing Cable Guiderail n n " Telephone Manhole O MISCELLANEOUS: — s Hydro, Pool or Reservoir -----7 Proposed Cable Guiderail n n n Telephone Booth Fil Utility Pole a Jurisdictional Stream is - Equality Symbol Telephone Pedestal D Utility Pole with Base p N Buffer Zone 1 az Pavement Removal ® Telephone Cell Tower i Utility Located Object O Buffer Zone 2 az s VEGETATION.• UG Telephone Cable Nand Hole E@Utility Traffic Signal Box m N Flow Arrow- Single Tree fl Recorded lYG Telephone Cable Utility Unknown U'G Line M -- Disappearing Stream Single Shrub © Designated U/G Telephone Cable (S.U.E.') - - - - - - - - - UG Tank; Water, Gas, Oil >— — o Spring oma' �_-� Recorded UG Telephone Conduit ASG Tank; Water, Gas, Oil Hedge w Wetland Woods Line Designated U/G Telephone Conduit (S.U.E.*y - - - - - - - - LvG Test Hole (S.U.E.') m m' Proposed Lateral, Tail, Head DitchOrchard €? 4 Q Q Recorded U/G Fiber Optic Cable T E° Abandoned According to Utility Records AATUR False Sump m Vineyard "eY°ra Designated WG Fiber Optics Coble (S,U.E," y - - - —I °- - - End of Information E.O.I. P P m NOTE: PAVEMENT EDGE SLOPES ARE I: /UNLESS SHOWN OTHERWISE. Cl D2 L------------------------------� U1 WEDGING DETAIL FOR BRIDGE NOT TO SCALE 26.17' I I YAR 10' I 10' YM I i CI RADE Cl 2.33' 01 I !GINE Dl 2.33' .D2 :TTP ,02 FM El D2 I D2 El ORlO1NAl GROUND I �✓ )= = ))F--- OWE TO THIS UNE USE TYPICAL SECTION "2 (NTS) -L- 14+15.08 - 14+84.08 1" GROUND ORIGl� MEOJECE REFERENCE NO, PROP. APPROX. 3" ASPHALT CONCRETE SURFACE COURSE, TYPE S9.5B, AT C1 AN AVERAGE RATE OF 336 LBS. PER SQ.YD. IN EACH OF TWO LAYERS. kW SHEEP NO. PROP. APPROX. 21,�" ASPHALT CONCRETE INTERMEDIATE COURSE, TYPE D1 I19.OB, AT AN AVERAGE RATE OF 285 LBS. PER SQ. YD. HYORAUUCS PROPOSED VARIABLE DEPTH ASPHALT CONCRETE INTERMEDIATE D2 COURSE, TYPE I19.OB, AN AVERAGE RATE OF 114 LBS. PER SQ. YD. PER 1" DEPTH. PROP. APPROX. 4" ASPHALT CONCRETE BASE COURSE, TYPE B25.OB, E1 AT AN AVERAGE RATE OF 456 LBS. PER SQ. YD. T EARTH MATERIAL. u EXISTING PAVEMENT. U1 CONCRETE CORED SLABS NOTE: PAVEMENT EDGE SLOPES ARE I: /UNLESS SHOWN OTHERWISE. Cl D2 L------------------------------� U1 WEDGING DETAIL FOR BRIDGE NOT TO SCALE 26.17' I I YAR 10' I 10' YM I i CI RADE Cl 2.33' 01 I !GINE Dl 2.33' .D2 :TTP ,02 FM El D2 I D2 El ORlO1NAl GROUND I �✓ )= = ))F--- OWE TO THIS UNE USE TYPICAL SECTION "2 (NTS) -L- 14+15.08 - 14+84.08 1" GROUND ORIGl� MEOJECE REFERENCE NO, SHEET NO. 8-5202 2 kW SHEEP NO. -L- 3" (Z C BRG. GRADE PT. Cl p 0.02 UDADWAY DESIGN I HYORAUUCS ENGINEER ENGINEER zz•-n- -0" 3D'-10"(CLEAR ROADWAY) 0" 15'-5' -L- 3" (Z C BRG. GRADE PT. Cl p 0.02 7' Q BRG. 3" G) C BRG. p T 0.02 ` 0 0 0 0 00 00 00 .- ul ut 16-6- 11 PRESTRESSED CONCRETE CORED SLAB UNITS = 33'-0' TYPICAL BRIDGE SECTION (NTS) -L- STA 14+96.08 TO -L- STA 16+16.08 USE TYPICAL SECTION *l (NTS) -L- 11448.29 - 14+15.08 -L- 16+28.08 - 19+70.69 tOUND tROJE�Tla\ EAUFORT\85202\b5202_ddc2_psh_2a.dgn :$USERNAME$$$$ 0 CA oy 0 m TOP OF FILL TOP OF FILL --7 TOP OF FILL �} <"1 ~} Z Q Q DHOxQF o t! r O m -i U)GROUNDLINE Z -I = > H GROUND LINE H GROUND LINE H "all n U IL_ -� Z Hm-H —" 00 OO:Dn-1 = m T= T � Cs�z Q LL. =- I U CG CD Z H -a r T AFTER /-COMPACT - - . - - - PLACED - - - '=' _ COMPACT AFTER 0CG H = f" Z LLJ n =:13 Z r n PRIOR TO �' OF - - - rn TYPE IV r - - - - - - - r-' aIPE IS PRIOR TO PLACED O L - 0 I O �¢l > D� H CD O n FILL r ENGINEERING rr PLACEMEN OF - - I '. '•': ... ". .: .' FABRIC -_ .::.:• ::: x FILL jT = �rcur= ur IND./e YIN. ,q :,n 1. D./6 MIN. _ LL _ -- =,u�r THAN 8 O W Z H > (L ~ I NOT LESS THAN 6" I.D.16 MIN. ,'w� = nr �r„=n ”, ,n=w_ rn=ru;rr,= ru_, n EARTH 3' NOT LESS THAN 6" 1•g" PER FOOT OF ' BUT NOT LESS THAN 12" NOCK O.D. + 3' NOR MORE THAN 24 O.O. + 3' a LL1M 0 UZ ' .rrr_VR„=rr I.D./8 MIN. rrr. NOT N.- �� NORMAL EARTH FOUNDATION ROCK FOUNDATION AS DIRECTED BY EHGR. NOT LESSITTNN I.D.16 MIN. r,ur� nr=n,�nr= rn=rn_,,, 7}UN 8 rq w= EARTH BUT O.D. + 9' NOT LF33 THAN 6" 1.4" PER FOOT OF `.1— wCL 0 0 UNSUITABLE MATERIAL FOUNDATION PIPE IN TRENCH 3 TOP OF FILL-----7TOP OF FILL TOP OF FILL----; ROCK FOUNDATION ME � MATERIAL FOUNDATION o 2 m PIPEIN TRENCH vJam_ MIN. O.D. H MIH. 0.0. _ YIN. O.D. H MIN. O.D. — MIN. O.D. H MIN. O.D. _ o r O W ♦ — J_ ♦ 7- GROUND LINE7, ♦ - GROUND LINE T -J J Z Q GROUND LINE 7 IV H m 0 m ENGINEERING - --.- - - - - - -_- - - - - FABRIC - -_- - - - W ti% IL Q X D r m '-' r -u, _ �r u_„r-nr=m- -rr •.=rrFrn=m_mGm�w ">r--. .. _= COMPACT AFTER' .. .... — —PIPE IS PLACED y • .'. �n COMPACT AFTER .. '.' .: -' ... ' • . • = l PRIOR TO E.D.l6 YIN. = PIPE IS PLACED PUACEYENT OF cc Z H --L 0 a W m F"I O i PRIOR TO NOT LESS THiUU B” m_n,=,n=,n=rrr= rn _p, =_nr FILL =_ur --}C PST I.D./8 MIH. -1 m H W J H Z LAS DIRECTED FILL 0.0. + 2' NOT LESS N� 6" O.D.+ 2' NOT LESS THAN 6" YIN. 0.0. YIN. O.D. BY ENGINEER N H W X (A � 1¢" PER FOOT OF 'If O W m � NORMAL EARTH FOUNDATION ROCK FOUNDATION NoaBNOTTHAN TTM N 12" LL _j r UNSUITABLE MATERIAL FOUNDATION = 0 m .D PIPE ABOVE GROUND C/) O T GENERAL NOTES: J Q O 37 I.D. - THE MAXIMUM HORIZONTAL INSIDE DIAMETER DIMENSION. 00 NOT OPERATE HEAVY EQUIPMENT OVER ANY PIPE CULVERT UNTIL THE PIPE CULVERT HAS BEEN PROPERLY BACKFILLED AND COVERED WITH AT LEAST 3 FEET OF APPROVED MATERIAL. ll Z O LIJ ~ O.D. - THE MAXIMUM HORIZONTAL OUTSIDE DIAMETER DIMENSION. - - - - - - - SPRINGLINE OF PIPELu = IL Z H - THE FILL HEIGHT MEASURED VERTICALLY AT ANY POINT SELECT BACKFILL MATERIAL CLASS III OR CLASS II, TYPE 1 r ALONG THE PIPE FROM THE TOP OF THE PIPE TO THE TOP ABOVE AND BELOW SPRINGLINE. M O DO OF THE EMBANKMENT AT THAT POINT, D 37 APPROVED SUITABLE LOCAL MATERIAL. Z O W = ~ ® TAKE CARE TO FULLY COMPACT HAUNCH ZONE OF PIPE BACKFILL. W Z rrGrrr= rri err UNDISTURBED EARTH MATERIAL �► LOOSELY PLACED SELECT MATERIAL CLASS III OR CLASS II, TYPE 1 HAM.FDR PIPE BEDDING. LEAVE SECTION DIRECTLY BENEATH PIPE SELECT MATERIAL CLASS V OR VI FOR FOUNDATION CONDITIONING. ENCAPSULATE OMPACTED AS PIPE SEATING AND BACKFILL WILL WITH ENGINEERING FABRIC AS DIRE-CTED BY THE ENGINEER. ACCOMPLISH COMPACTION. SHEET 1 OF 3 SHEET 1 OF 3 300D01 300D01 v CA oy O m H D TOP OF FILL-----7TOP OF FILL ----TOP OF FILL O � � " ~} Z Q Q = U O o t! FD-' HO 0 in GROUND LINE H GROUND LINE H GROUND LINE H cc C'3 10 HZ=> —" ICJ=HZ �O n� = -n= m �1zD 111 �l _rrr=------.------' u,>=n_ cru=u=rrr-,,,_ m�m�u_n= ------ ------ mow- - ------ ------ _u=m�u,= mc,,,x n_u T1 a=wcnr_ r� �r — — — r _, rn u' Ir .. WQ LL= U O _ (p O O Z ra rn COMPACT AFTER 'u rp ur in IF Q _ HDi F- ~ Z H O r O= _ -. - _ _ _r PIPE IS PLACED - _ - _ - _ _ r_i -. - - rs PCOMPACS PLACED k PRIOR TO ri S i L PRIOR TO W O~ O LLL"L J D PLACEMENT OF - TYPE IV �� :.... nrPLACEMEN OFO..,:... . FILL rrr ENGINEERING = I ... FABRIC'FILLH �., '. .. '.• .• '. ern m M UZ ' .rrr_VR„=rr I.D./8 MIN. rrr. NOT N.- �� NOT LESSITTNN I.D.16 MIN. r,ur� nr=n,�nr= rn=rn_,,, 7}UN 8 rq w= EARTH BUT O.D. + 9' NOT LF33 THAN 6" 1.4" PER FOOT OF `.1— wCL 0 0 ROCK O.D, + 3' NORR MMORELTHAN 2412"O.D.NORMAL EARTH FOUNDATION AS DIRECTED BY END...UNSUITABLE ROCK FOUNDATION MATERIAL FOUNDATION PIPEIN TRENCH 3 TOP OF FILL TOP OF FILL TOP OF FILL m Z ~ 2 m O H H H O Q (Z O r — LL J H O 2 GROUND LINE GROUND LINE MIN. O.D MIN. 0.0 MIN. O.D.O.D, MIN, O.D.O,D. TYPE IV MIN, O.D. MIN. O.D. aQ (AROUND LINE � ET ERING FAN. G1{ANCC H 1-1_ nCEON =_ZWIL 0 m .D AFTER" 1 .. .. PIPE IS PLACED .'L'-<' -. r r 1 MIN. PLACIOEYENi OF :. '. - a PR NOT LESS THAN 6" u= = nr Jn=„r_ r = _ FILL rr_rn_ ru Jrr�,_ . ._.ru-, rrr - rr 0 ~ --I W H a H H O m Z D I.D,/e M. L/S DIRECTED COMPACT AFTER 0.0. + 2' I.D./8 MIN. NOT LEAS THAN 6" MIN, O.D. MIN, O.D. 8Y ENGINEER IS NIDI LESS TFUW B" 0.0.+ 2'" ~ ~ (:i Ly d N IIP PRIOR TOMS PER F007 OF 'M PLACEMEN O = -1 H OF BUT NOT LESS 71" 12- FILL NORMAL EARTH FOUNDATION ROCK FOUNDATION NOR MORE THAN 24 = IL UNSUITABLE MATERIAL FOUNDATION r PIPE ABOVE GROUND M O DO GENERAL NOTES: D 37 I. D. THE NMI" HORIZONTAL INSIDE DIAMETER DIMENSION. DO NOT OPERATE HEAVY EQUIPMENT OVER ANY PIPE CULVERT UNTIL THE PIPE CULVERT HAS BEEN PROPERLY BACKFILLED AND COVERED WITH AT LEAST 3 FEET OF APPROVED MATERIAL. Z O W = ~ O.D. - THE MAXIMUM HORIZONTAL OUTSIDE DIAMETER DIMENSION. - - - - - - - SPRINGLINE OF PIPE W Z H - THE FILL HEIGHT MEASURED VERTICALLY AT ANY POINT SELECT BACKFILL MATERIAL CLASS III OR CLASS II, �► ALONG THE PIPE FROM THE TOP OF THE PIPE TO THE TOP BELOW SPRINGLINE. OF 7}f EMBANKMENT AT THAT POINT. ® APPROVED SUITABLE LOCAL MATERIAL ABOVE SPRINGLILE. ® TAKE CARE TO FULLY COMPACT HAUNCH ZONE OF PIPE BACKFILL. rr�rrr=rrr_rr UNDISTURBED EARTH MATERIAL TYPE 1 LOOSELY PLACED SELECT MATERIAL CLASS III OFF CUA4S II, CL FOR PIPE DECIDING. LEAVE SECTION DIRECTLY BENEATH PIPE SELECT MATERIAL ASS V OR VI FOR FOUNDATION CONDITIONING. ENCAPSULATE UNCOMPACTED AS PIPE SEATING AND BACKFILL WILL WITH ENGINEERING FABRIC AS DIRECTED BY THE ENGINEER. ACCOMPLISH COMPACTION' HEET 2 OF $ SHEET 2 OF 3 300DO1 300D01 Hao ioH CA oy LMp iormr. m o� m=om .ww m�C aym o t! jZ-"1 M mom ao � M O c� DD H11 Hmm y-nmrn maw rC � m M —' CN'i $ m mZ z 0 %C(JRWEAUFORT\65202\b5202_ddc2_psh_2b.dgn _$USERNAME$$$$ iio opo/w i FLEXIBLE PIPE m m oN M mZ�' '• .v maw m„C- ►+'1 Z Round Corrugated Steel Pipe Round Corruaated Aluminum Pipe Z �? H O 0 2 213 x l -t corrugation ' 2 213 x )t corrugation " E W J M r-0�-4 �o 0(:>w= Z M Z -(Z D -4 Diameter Minimum cover Maximum Height of Cover (feet) 8 Diameter Minimum cover Maximum Height of Cover inches inches (Ga) 16 14 12 10 (feet) 8 [C W Q Z U- O O (7 -n D Cn-33 inches inches (Ga) 16 14 12 10 12 12 123 155 218 281 344 H U O t'3 y Cl) 1 O 12 12 15 12 204 256 162 204 15 12 98 123 174 224 275 F¢- oc H Z H = 2f + t- -n 18 12 135 169 239 Is 12 81 102 144 187 228 1n )-- W O J z 21 12 115 145 204 21 12 69 87 123 160 195 0 O � --i ' D 24 12 100 126 178 24 12 80 76 106 138 95 123 171 151 Z H 5i--I 30 12 79 100 142 27 12 67 H �--� co 0W 36 12 42 12 65 83 11Y 152 55 70 700 130 160 30 1 2 '60 85 111 36 12 50 71 92 136 113 CL o p Z 48 12 54 12 48 61 87 113 139 54 77 100 123 42 12 60 78 48 12 52 68 96 84 60 12 69 9D 111 54 12 46 50 74 66 12 81 100 60 12 50 62 72 12 74 91 66 12 51 78 12 81 72 12 41 3 84 12 69 Z M " I *' FOR DIFFERENT CORRUGATIONS AND ARCH PIPES REFER TO ~ ~ 2 m ROADWAY DESIGN MANUAL OR MANUFACTURERS SPECIFICATION. 0 0 LL D r REFER TO THE FOLLOWING FOR PIPE SPECIFICATIONS 0 ..I Q N 0Z � = CSP - AASHTO M36 W 1r 0 HDPE ' (Minimum fill) 2' for pipe diameters > 12" and < 60" GAAP - AASHTO U196 HDPE - AASHTO M294 Z _ ' (Maximum fill) 20' for pipe diameters < 24" PVC - ASTM F949 or AASHTO M304 p N 111 N--1 H _ < 60" 17' for pipe diameters > 30" and = ci ~ M = t- PVC - ' (Minimum fill) 2' for pipe diameters > 12" and < 36" NOTES: FILL HEIGHTS SHOWN WERE CALCULATED USING Juw �� H ' (Maximum fill) < 30' for pipe diameters > 12" and 36" AASHTO LRFD, BRIDGE DESIGN SPECIFICATIONS Fa- W H vLU —( z D ii D,7 `Z ' FILL HEIGHT IS MEASURED FROM THE TOP OF THE PIPE 1' MINIMUM COVER FOR ALL SIDE DRAIN PIPE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS _ J r H Z TO THE BOTTOM OF THE PAVEMENT STRUCTURE N O H (1) r' " RIGID PIPE -j LL CD O RCP - " (Minimum fill) 1' for Class IV & CLASS V W 1-1 2' for Class III & Class II REFER TO THE FOLLOWING FOR PIPE SPECIFICATIONS � z ' (Maximum fill) 10' - Class II pipe RCP - AASHTO M170 LLL 20' - Class III pipe 30' - Class IV pipe 40' - Class V pipe NOTES: FILL HEIGHTS SHOWN WERE CALCULATED USING (For fills > 40' & < 80' use LRFD Direct Design Method) AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS • FILL HEIGHT IS MEASURED FROM THE TOP OF THE PIPE TO THE BOTTOM OF THE PAVEMENT STRUCTURE 1' MINIMUM COVER FOR ALL SIDE DRAIN PIPE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS SHEET 3 OF 3 HEET 3 OF 3 I 300DO 1 30 0 DO 1 iio opo/w i oN -n lob m m !' mZ�' '• .v maw m„C- t" C) a 0 ;a-4 E m mem �o � O M „mc) goo DD � XF�•1m imm mrd ro C u CAM -4 a m m= IP PROJECT RERRBNC! NO. SHEET NO. COMPUTED BY:Vr DATE: 3-4541 STATE OF NORTH CAROLINA 8-522 CHECKED BY: LL-,: DATE 31-1541 DIVISION OF HIGHWAYS NOTE: Invert Elevotions are for aid Purposes only and shall not be used for project construction stakeout. See 'Standard Specifications For Roads and Structures, Section 300-5'. LIST OF PIPES, EADWALLS, ETC. (FOR PIPES 48" & UNDER) ENDWALLS s C z m Q 8 ABBREVIATIONS R.C. RE 114 PIPE ffD.11!0.01, o R rj C.0. CATCH 6WN IV. N.D.L NARROW DROP INLET DRAINAGE PIPE CORRUGATED STD. 838.11 c Q p,1, DROP INLET STATION � (RCP, CSP, UAP, HDP!, a PVCj ALUMINUM PPE (CLASS s9 (CUSS M o OR � � + FIAME, GRATES � �pp i STD. 333.110 ANDSTANDARD OD 0.7 G ' ZSZZpNOTED g p �1 E( p Y 001. GRATED DROP INLET Z < OTHERWCLE) (N.S.) GRATED DROP J.0. JUNCTION BOX WE F` $ m 12' IS' Is, 24' 30' 36' 42' 411' yi 12' 15• 111' 24• 36' 42' 45' 15' 111' 24' 30' 36' 42' 43' 12' 15' Ir 24. 30' 36. 42. 4V s � � � � CU. YDS. � A B 3 .� L' � M.M. MANMOLE EI q a TJ.D.L TRAFFIC BEARING DROP INLET W 0 0 ° 27 T.BJ.S, TRAFFIC SEARING JUNCTION BOX THICKNESS O e IS C O 'p TYPE OF ORATE O0. GAUGETIP O S S S 4 S $ I i 1 b J C vi E I f 4- U+19.93 -Ir U+19.93 -4- 14+19.93 4- U+19.93 4-16+44.62 TOTALS 'N' - DISTANCE FROM EDGE OF LANE TO FACE OF GUARDRAIL UNCLASSIFIED EXCAVATION UNDERCUT EMBT+% BORROW WASTE -L- 12+00.00 - 15+20.79 TOTAL SHOULDER WIDTH - DISTANCE FROM EDGE OF TRAVEL LANE TO SHOULDER BREAK POINT. 0 90 37 0 -L- 16+50.00 - 19+47.00 44 FLARE LENGTH - DISTANCE FROM LAST SECTION OF PARALLEL GUARDRAIL TO END OF GUARDRAIL 46 0 TOT 157 W - TOTAL WIDTH OF RARE FROM BEGINNING OF TAPE& TO END OF GUARDRAIL UNDERCUT (CONTINGENCY) SAY SUMMARY 240 G - GATING IMPACT ATTENUATOR ME 3$0 200 GUARDRAIL NG NON -GATING IMPACT AITENUATOR TYPE 350 UNCLASSIFIED STRUCTURE EXCAVATION 460 0 0 0 460 IMPACT LENGTH WARRANT POINT IN. 323 FLARE LENGTH W ANCHORS iRN6L! AND (WLM ANCHOR DEDUCTIONS) per. TOTAL SAY 560 DARDRACSTING S REAtAIRKS SURVEY BEG. STA LOCATION 330 FROM SMOULDER TfPEGIMRDRAL USII09L! OUARDRAL FX511NG UNE SHOP DOUBLE APPROACH TRAILING LO.L WAN ��ROACH TRAILING AMROACN TIWUNG GUUDRAL D FACED BID END END END END END 350 IB kTY"350 4- 12+17.94 15+73.05 RT 25750 1.4 5.33 50 4- 13+67.63 15+7 AAS IT 13750 15+73.88 5.33 50 lA I 4- 16+31.13 17+02.87 IT 222.93 25 16+31.13 1.4 5.33 1.0 1 1 4- 16+31.13 19+03.00 IT 229.61 25 16+31.13 1A 30 1 1 TOTAL 87734 50 4 4 SUMMARY OF EARTHWORK IN CUBIC YARDS LOCATION UNCLASSIFIED EXCAVATION UNDERCUT EMBT+% BORROW WASTE -L- 12+00.00 - 15+20.79 53 0 90 37 0 -L- 16+50.00 - 19+47.00 44 0 46 0 TOT 157 UNDERCUT (CONTINGENCY) SAY 0 240 240 200 UNCLASSIFIED STRUCTURE EXCAVATION 460 0 0 0 460 SUB O 557 200 420 323 660 SAY 560 200 420 330 660 PAVEMENT REMOVAL SUMMARY IN SQUARE YARDS LINE STATION -STATION Lo ON REMOVAL (SY) -L- 15+10 - 15+44 CL 86 -L- 16+31 - 16+ CL 71 TOT 157 SAY 160 i 0 r RIGHT OF WAY AREA SUMMARY PARCEL NO. PROPERTY OWNER NAME I LOCATHON TOTAL PARCEL AREA IACRESI AREA TO OE DEDICATEDTO BE PURCHASED (CONST. EASBHEN7) (RIGHT OF WAY) vxl v aEal PARCEL AREA REMAN NO IACREQ 1 0.H, BISHOP, 10., Ef AL IT 516.27 0.059 516.15 O O 15011641 R.H. BISHOP, JR., ET AL 643 WATER STREET BELHAVEN, NC 27810 DB 775 PG 283 81627 AC CULTIVATED FIELD DATUM DESCRIPTION THE LOCALIZED COORDINATE SYSTEM DEVELOPED FOR THIS PROJECT IS BASED ON THE STATE PLANE COORDINATES ESTABLISHED BY NCDOT FOR MONUMENT 'GPS -100' WITH NAD 83/NSRS 2007 STATE PLANE GRID COORDINATES OF NORTHING: 689249.672(ft) EASTING: 2700770.1D4(ft) ELEVATION: 7.97(ff) THE AVERAGE COMBINED GRID FACTOR USED ON THIS PROJECT (GROUND TO GRID) IS: 0.999896T2 THE N.C. LAMBERT GRID BEARING AND LOCALIZED HORIZONTAL GROUND DISTANCE FROM 'GPS -100' TO -L- STATION 10+00.00 15 S 50'22'03' W 2233.5602' ALL LINEAR DIMENSIONS ARE LOCALIZED HORIZONTAL DISTANCES VERTICAL DATUM USED IS NAVD 88 Q P.N 8-5202 4 RNV SHEET NO. PI Sto 13+1094 Eti j a GUY SIRE AeWF E.Sl- A- D = 0' 04' 03.6' _ F F1V� 350 L = 140J3' F Ev51WG R/w CVA7ROL PO1Nr 'l O T = 70DF -L- STA /O+�bB v 11.57 15011641 R = 84.680.0(1' 2735 RT R.H. BISHOP, JR., ET At ENE-66p87806..p43/0 SOIL" GUY Ib 643WAENNSTREET ELEV�%.04W - _BASE BEL27810 - BM•108.2 -Bb 9L+ DB TT5 PG 283 T 32.0 - v -I. B1627 AC DATUM DESCRIPTION THE LOCALIZED COORDINATE SYSTEM DEVELOPED FOR THIS PROJECT IS BASED ON THE STATE PLANE COORDINATES ESTABLISHED BY NCDOT FOR MONUMENT 'GPS -100' WITH NAD 83/NSRS 2007 STATE PLANE GRID COORDINATES OF NORTHING: 689249.672(ft) EASTING: 2700770.1D4(ft) ELEVATION: 7.97(ff) THE AVERAGE COMBINED GRID FACTOR USED ON THIS PROJECT (GROUND TO GRID) IS: 0.999896T2 THE N.C. LAMBERT GRID BEARING AND LOCALIZED HORIZONTAL GROUND DISTANCE FROM 'GPS -100' TO -L- STATION 10+00.00 15 S 50'22'03' W 2233.5602' ALL LINEAR DIMENSIONS ARE LOCALIZED HORIZONTAL DISTANCES VERTICAL DATUM USED IS NAVD 88 Q r -- P) 8-5202 4 RNV SHEET NO. PI Sto 13+1094 d xC MW1' 99 a p = 0 05' 41.3' (RT) in D = 0' 04' 03.6' _ F F1V� —___— ��— L = 140J3' Q. 04. T 17.30 T = 70DF v 11.57 RT 46.97 c EV 8.6 R = 84.680.0(1' ' SOIL" GUY Ib WIRE I ®®� ® ®® - _BASE - BM•108.2 -Bb 9L+ , a T ® T 32.0 - v -I. . EL=8.64' 7. N 7. 4 Sta. 16+5833 -L- .. .. .. .. .. .. .. .. CAT4 Tw 3.01 15+ 9,gq -LEv T r -- P) 8-5202 4 RNV SHEET NO. ROADWAY DESIGN EMOINRR HYDRAULICS ENGINEER xC MW1' 99 a � £0 BST ® _ F F1V� —___— ��— 04. T 17.30 0. v 11.57 RT 46.97 c EV 8.6 CULTIVATED FIELD ® ® u I..T 82.5188 rE ISTING BRIDGE -18 .' SHLL uuDc- f l7--N5ORiEN�EANOST SSIDE ED TEDESjE SIpE, w /ww CONC RAILS, CROSS BEAMS. AND DECK BST PAVING -D- PI Sto 10+33.01 p = 45' 00' 00.0' (LT ) D = 381*58' 18.7' L = 1178' T = 621' R = 15,00' O 15011641 R.H. BISHOP. JR., ET AL 643 WATER STREET BELHAVEN. NC 27810 DB 775 PG 283 816.27 AC CULTIVATED FIELD 8:1 OCULTIVATED FIELD 15011641 R.H. BISHOP, JR., ET AL 643 WATER STREET BELHAVEN. NC 27810 DB 775 PG 283 81627 AC O N h PROJECT REFERENCE NO. SHEET NO. 8-5202 4 RNV SHEET NO. ROADWAY DESIGN EMOINRR HYDRAULICS ENGINEER 4 c17NrROL P01NT ' -L- STA 21+9383 3155' R7 N-68867S/p8b E=26999105450 £LEY.- 718 STATE O IF NORTH CAROLINA STATH PRW 5f RSFRRHNCS NO, SHEET NO. DIVISION OF HIGHWAYS 8-5202 TCP -1 PLAN FOR PROPOSED TRAFFIC CONTROL BEA UFOR T COUNTY ROADWAY STANDARD DRAWINGS THE FOLLOWING ROADWAY STANDARDS AS APPEAR IN "ROADWAY STANDARD DRAWINGS" - HIGHWAY DESIGN BRANCH-N.C. DEPARTMENT OF TRANSPORTATION -RALEIGH, N.C., DATED JULY 2006 ARE APPLICABLE TO THIS PROJECT AND BY REFERENCE HEREBY ARE CONSIDERED A PART OF THESE PLANS: STD. N0. TITLE 1101.11 TRAFFIC CONTROL DESIGN TABLES 1110.01 STATIONARY WORK ZONE SIGNS 1146.01 BARRICADES (TYPE III) INDEX OF SHEETS SHEET NO. TITLE TCP -1 LIST OF APPLICABLE ROADWAY STANDARD DRAWINGS, LEGEND AND INDEX OF SHEETS TCP -2 PROJECT NOTES, DETOUR, AND PLANS APPRO SEAL LEGEND GENERAL 40 DIRECTION OF TRAFFIC FLOW �-- NORTH ARROW PROPOSED PVMT.--------- EXIST. PVMT. - WORK AREA REMOVAL OF EXISTING PAVEMENT TRAFFIC CONTROL DEVICES TYPE I BARRICADE TYPE II BARRICADE m TYPE III BARRICADE . CONE . DRUM O SKINNY DRUM FLASHING ARROW PANEL (TYPE C) �— STATIONARY SIGN PORTABLE SIGN N STATIONARY OR PORTABLE SIGN -I\f\i, CRASH CUSHION CHANGEABLE MESSAGE SIGN TRUCK MOUNTED IMPACT ATTENUATOR (TMIA) ® POLICE FLAGGER PLAN PREPARED BY: N.C.D.O.T. DIVISION 2 DDC UNIT . H. ALLIGOOD, PE TRAFFIC CONTROL ENGINEER D. H. ALLIGOOD, PE TRAFFIC CONTROL PROJECT ENGINEER LANG JONES TRAFFIC CONTROL PROJECT DESIGN ENGINEER GENERAL NOTES IMPLEMENT TRAFFIC CONTROL IN ACCORDANCE WITH THE ROADWAY STANDARD DRAWINGS LISTED ON TCP -1. CHANGES MAY BE REQUIRED WHEN PHYSICAL DIMENSIONS IN THE DETAIL DRAWINGS, STANDARD DETAILS AND ROADWAY DETAILS ARE NOT ATTAINABLE TO MEET FIELD CONDITIONS, OR RESULT IN DUPLICATE, OR UNDESIRED OVERLAPPING OF DEVICES. MODIFICATION MAY INCLUDE: MOVING, SUPPLEMENTING, COVERING OR REMOVAL OF DEVICES, AS DIRECTED BY THE ENGINEER. STATE FORCES WILL INSTALL AND MAINTAIN THE PROJECT DETOUR AND THE TYPE III BARRICADES AT THE PROJECT LIMITS. STATE FORCES WILL INSTALL PAINT AND MARKERS ON THE FINISHED PROJECT. CALL JIM EVANS AT 252-830-3493 FOR COORDINATION. R11-2 48"X30" TYPE III BARRICADE A"ROYED: DATE SEAL R11-2 48"X30" ROAD CLOSED moi. ure"NC! NO. SHEET NO. B-5202 TCP -2 TYPE III BARRICADE -- NC M% 99 --- 29 BSl PROJECT NOTES NONE REVISIONS 12/17/09 n LJ (Ij O N LP i N 0 N CQ F - Of 0 ars, w N tl]�j oil �ING —F -Z OVA NLdW SON See Sheet 1-4 For Index of Sheets BEGIN TIP PROJECT B-5202 —L— STATION 11420.00 TO SR 1625 --- N6 --W-)7-99 20' BST STATE OF NORTH CAROLINA DIVISION OF HIGHWAYS BEA UFOR T COUNTY �(�(�]�LAN FOR PROPOSED HIGHAY EROSION CONTROL 1605.0: 1606.0 1632.0; BEGIN APPROACH SLAB —L— STATION 14484.08 END APPROACH SLAB —L— STATION 16428.08 NG .F¢¢tt C P' ECS 11c following ,,,d,,,,aa&Sh „.kn% -,Wpm In *Ro•dwn s-Ld-d D-wW- RmdwvDodo Unit- N. C. Departmeoc-tWTmworudoa - R.1d@t, N. C., dmd Jab 1S,1006 and de k ow � arc, a boalo to de. p.,� ma b, t�aa� baso we oaaaa«ea itpw of lfinu 1604.01 R.uro.d F.adm Coocol Dat.s 1630.06 Special Belstq H.da _ ------Conol- 45300.2.1 BRSTP-0099 9 RW 45300.3.1 SRSTP-0099 9 CONST I P A N E G 0 —.. ..—._—.-Conal t S W A N P 626 Mominp Star Ch. t PROJECT 8-5202 Swinde0 99 � 1625 \ 2 PANTEGO . 1626 MP. 171 Wilkinson W 7 • S 264 pP� /16 1 -' VICINITY MAP (NOT TO SCALE) See Sheet 1-4 For Index of Sheets BEGIN TIP PROJECT B-5202 —L— STATION 11420.00 TO SR 1625 --- N6 --W-)7-99 20' BST STATE OF NORTH CAROLINA DIVISION OF HIGHWAYS BEA UFOR T COUNTY �(�(�]�LAN FOR PROPOSED HIGHAY EROSION CONTROL 1605.0: 1606.0 1632.0; BEGIN APPROACH SLAB —L— STATION 14484.08 END APPROACH SLAB —L— STATION 16428.08 END TIP PROJECT B-5202 —L— STATION 20400.00 20' BST TO SR /629 GRAPHIC SCALE'S NG .F¢¢tt C B-5202 ECS 11c following ,,,d,,,,aa&Sh „.kn% -,Wpm In *Ro•dwn s-Ld-d D-wW- RmdwvDodo Unit- N. C. Departmeoc-tWTmworudoa - R.1d@t, N. C., dmd Jab 1S,1006 and de k ow � arc, a boalo to de. p.,� ma b, t�aa� baso we oaaaa«ea itpw of lfinu 1604.01 R.uro.d F.adm Coocol Dat.s 1630.06 Special Belstq H.da 45300.1.1 BRSTP-0099 9 PE 45300.2.1 BRSTP-0099 9 RW 45300.3.1 SRSTP-0099 9 CONST LENGTH STRUCTURE TTP PROJECT 8-5202 = 0.027 MILE TOTAL LENGTH OF TIP PRO ECT B-5202 = 0.167 MILE J RIGHT OF WAY DATE: DWAYNE H. ALUGOOD Do.criFli.a STmba] High Vi. Temp.r.ry SikF--------- III HI Iii Sp -i.] Sediment C..tr.] F--..- ... R.Ch I.W Srdi—t T-p,C ........................... THIS PROJECT CONTAINS EROSION CONTROL PLANS FOR CLEARING AND GRUBBING PHASE OF CONSTRUCTION. ENVIRONMENTALLY SENSITIVE AREA(S) EXIST ON THIS PROJECT END TIP PROJECT B-5202 —L— STATION 20400.00 20' BST TO SR /629 GRAPHIC SCALE'S Prepared In fir? Office of: Roadway soma Drswbo 50 25 0 5 11 0 100 PROJECT LENGTH LENGTH ROADWAY TIP PROJECT B-5202 = 0.140 MILE .� DIVISION OF HIGHWAYS 1704 North Greexe Start Gr.eeollle, NC 27835 11c following ,,,d,,,,aa&Sh „.kn% -,Wpm In *Ro•dwn s-Ld-d D-wW- RmdwvDodo Unit- N. C. Departmeoc-tWTmworudoa - R.1d@t, N. C., dmd Jab 1S,1006 and de k ow � arc, a boalo to de. p.,� ma b, t�aa� baso we oaaaa«ea itpw of lfinu 1604.01 R.uro.d F.adm Coocol Dat.s 1630.06 Special Belstq H.da Wino, srwxn�nn sPacurrc+zraxs PLANS LENGTH STRUCTURE TTP PROJECT 8-5202 = 0.027 MILE TOTAL LENGTH OF TIP PRO ECT B-5202 = 0.167 MILE J RIGHT OF WAY DATE: DWAYNE H. ALUGOOD mmol Temporary Sm Fenno 1632.1 Rota Inlet BedfmaotTrmv 'lyre A 1606,01 Special Sediment Control Fmoe 1632,02 Roti We Sedlmaot Trap Type B 160.01 Gr l Con mea ire 1632.63 Pooh Inlet sed>mmt T!rm Type C 1622.01 Tcmpor rT Bormt and Slope Drains 1633.1 Tcso,,mr, Rook SM Ch Type A 1630.1 RLar Baia 1634.1 TempmvT Rock Sedlmeot Dm TTpe A 1M'02 Tecworffr 811t Ditch 1634.02 TempoeuT Rook Sedtmont Dm T%mB MN 04 BOW Badu 16MM Rook Pipe Inlet Sedimot Trap Type A 1630.05 TampmcTDladm 163509 Rook Pipe Wet SedimotTrap Type B Patjcr Xhumm LANG JONES (#276) LETTING DATE: OCTOBER 2011 P1tt1 J= nast©v mmmm N o_ 9 Sp.dal S.dlnrrd Cowl Fo—: DrafpEom Tr wah oorww by tli asabn candeb dtM parnu6on, mdntananw, and prnord d apsapkh mdbna,r Lne.. Flaw ap.dd mdimas aonsollarw w.frown ort dr. plat a m ditsasd by th. Erybra. AVA.&W (/t Fwbl S1W paa 0= at Loa5 fam In 6rgth,.ppr.dmmtly t K Mraa Mks marasd wdW b dr Saw, end how a mlNmaln -ki *OIM bfldLlpth. TM pawalrR b..q*p.d with an md. 0.11m h.riry a mk-&— a dU.0 gawa Indy, end ahal hors o nraea of wtob,4p win N tM dsdrsd potbfon wYrld dbpl.oanad. MVA bwh It.rdrwm Giallo Itanlwan doh dr1 hww V4 bxh a pwAItp tawwued 4mr+ 02A papa wort bird h.,#— doh .a.,*m b 6. d.rS shown al the plata Shcm.rs C.'" P.— Ssdinrsearrsido F4 dd msa slM rpukaerm dfsmon 1006, Mrld dor a.radlM A dr dld ahwm en 1M pLrr. hu*ft rnm and Rw—C T. Carona drd molmdn V. gadd mdLr,+com,ol Lnw wd tM pow 1. ooaq. a "tM Ars b IWm.rwd, and .h.1 mmars and Af— diem.mArALIr adr Ras who, w dbaa.d by*. &.V— In oomdaw whh $..A. USO. Tr tlwAtF d pada Aadbrwd aa+wd oar and hadwr dash m nrwand abort wdbe pow fw*ION GNVFW orb fw'wmp Sam f.t Flsd, CaO'. 9I.h prim std p y wt wi b. kA wmpr�mbn i.r a1 wa4 oarasd b/ di Yrbldwp W M inb.d b, Wmldiq d maabb, b,a.iobn, and mmad and dbpod d CID q `,' P1 Sto 13+1094 c 0 0 = 0' 05' 413' (RT) n VI D = 0' 04'03L' �. U-) v L = 140J3' a. OI T = 70.06' 15014641 R = 84,680.00' R.H. BISHOP. JR.. ET AL 643 MATER STREET BELHAVEN, NC 27810 DB 775 PG 283 '� aFER 6uFFE 81627 AC ` - Cud°" E gq CULTIVATED FIELD GUY MIRE C1 aecr E t-1— n.r p O 15011641 R.H. BISHOP, JR.. ET AL 643 WATER STREET BELHAVEN, NC 27810 DB TT5 PG 283 81627 AC CULTIVATED FIELD &L-7 1).—a";.- 1606.01 ) - >;.-1605.01 Hi,h VI. T—"—, S;It F,n«__...__. u 1604.01 Sp.=;.] S.dam,.t C..t—1 F,.,........... 163203 R—k 1.6t S.d:r,.t Tr.p Trp, C -_...._..n 6-- LLBm-I -B 104' T EL -8.64' W W4 SHOP CuRVEi nvpl . n y I 30, 2a 6IFFEa 9 F'E2 ZOrL EXISTING BRIDGE •I8 30' w000- PILINN. STPoNGEIRSSIDE Hw/U.W TOIXNJ 5D1RT 11CA$T FfEa E'0' NNRSOUTHWESIEEL !Iw/ww ZONE 2 W'0'6N I SIDE GONG RAILS, CROSS BEAMS, AND DECK BST PAVING -D- PD Sto 10+33.01 p = 45' 00'00.0' (LT! D = J8)58'18.7' L = 1178' T = 621' R = 151X1' O 15011641 R.N. BISHOP. JR., ET AL 643 WATER STREET BELHAVEN. NC 27810 DB 775 PG 283 81627 AC CLr71VATED FIELD OCULTIVATED FIELD 15011641 R.H. BISHOP, JR., ET AL 643 MATER STREET BELHAVEN, NC 27810 DB TT5 PG 283 81627 AC V PROJECT REFERENCE NO. SHEET NO. B-5202 EC2 ry 50 25 0 50 100 h 0� PLANS 4 0 m NOTT3: ANY DEVIATION FROM OPTIONS GKN WILL REQUIRE PRIOR APPROVAL BY ENGINEER. ® RtraoPE RBARHAMA $a FtOXCT oolcr SrutAL NrovslDw ADDITIONAL EROSION CONTROL DEVICES MAY NEED TO BE INSTALLED AS DIRECTED BY THE ENGINEER. Sp.dal S.dlnrrd Cowl Fo—: DrafpEom Tr wah oorww by tli asabn candeb dtM parnu6on, mdntananw, and prnord d apsapkh mdbna,r Lne.. Flaw ap.dd mdimas aonsollarw w.frown ort dr. plat a m ditsasd by th. Erybra. AVA.&W (/t Fwbl S1W paa 0= at Loa5 fam In 6rgth,.ppr.dmmtly t K Mraa Mks marasd wdW b dr Saw, end how a mlNmaln -ki *OIM bfldLlpth. TM pawalrR b..q*p.d with an md. 0.11m h.riry a mk-&— a dU.0 gawa Indy, end ahal hors o nraea of wtob,4p win N tM dsdrsd potbfon wYrld dbpl.oanad. MVA bwh It.rdrwm Giallo Itanlwan doh dr1 hww V4 bxh a pwAItp tawwued 4mr+ 02A papa wort bird h.,#— doh .a.,*m b 6. d.rS shown al the plata Shcm.rs C.'" P.— Ssdinrsearrsido F4 dd msa slM rpukaerm dfsmon 1006, Mrld dor a.radlM A dr dld ahwm en 1M pLrr. hu*ft rnm and Rw—C T. Carona drd molmdn V. gadd mdLr,+com,ol Lnw wd tM pow 1. ooaq. a "tM Ars b IWm.rwd, and .h.1 mmars and Af— diem.mArALIr adr Ras who, w dbaa.d by*. &.V— In oomdaw whh $..A. USO. Tr tlwAtF d pada Aadbrwd aa+wd oar and hadwr dash m nrwand abort wdbe pow fw*ION GNVFW orb fw'wmp Sam f.t Flsd, CaO'. 9I.h prim std p y wt wi b. kA wmpr�mbn i.r a1 wa4 oarasd b/ di Yrbldwp W M inb.d b, Wmldiq d maabb, b,a.iobn, and mmad and dbpod d CID q `,' P1 Sto 13+1094 c 0 0 = 0' 05' 413' (RT) n VI D = 0' 04'03L' �. U-) v L = 140J3' a. OI T = 70.06' 15014641 R = 84,680.00' R.H. BISHOP. JR.. ET AL 643 MATER STREET BELHAVEN, NC 27810 DB 775 PG 283 '� aFER 6uFFE 81627 AC ` - Cud°" E gq CULTIVATED FIELD GUY MIRE C1 aecr E t-1— n.r p O 15011641 R.H. BISHOP, JR.. ET AL 643 WATER STREET BELHAVEN, NC 27810 DB TT5 PG 283 81627 AC CULTIVATED FIELD &L-7 1).—a";.- 1606.01 ) - >;.-1605.01 Hi,h VI. T—"—, S;It F,n«__...__. u 1604.01 Sp.=;.] S.dam,.t C..t—1 F,.,........... 163203 R—k 1.6t S.d:r,.t Tr.p Trp, C -_...._..n 6-- LLBm-I -B 104' T EL -8.64' W W4 SHOP CuRVEi nvpl . n y I 30, 2a 6IFFEa 9 F'E2 ZOrL EXISTING BRIDGE •I8 30' w000- PILINN. STPoNGEIRSSIDE Hw/U.W TOIXNJ 5D1RT 11CA$T FfEa E'0' NNRSOUTHWESIEEL !Iw/ww ZONE 2 W'0'6N I SIDE GONG RAILS, CROSS BEAMS, AND DECK BST PAVING -D- PD Sto 10+33.01 p = 45' 00'00.0' (LT! D = J8)58'18.7' L = 1178' T = 621' R = 151X1' O 15011641 R.N. BISHOP. JR., ET AL 643 WATER STREET BELHAVEN. NC 27810 DB 775 PG 283 81627 AC CLr71VATED FIELD OCULTIVATED FIELD 15011641 R.H. BISHOP, JR., ET AL 643 MATER STREET BELHAVEN, NC 27810 DB TT5 PG 283 81627 AC V PROJECT REFERENCE NO. SHEET NO. B-5202 EC2 ry 50 25 0 50 100 h 0� PLANS 4 0 z 0 2 GENERAL NOTES: USE NO. 6 OR NO. 67 STONE FOR SEDIMENT to CONTROL STONE. USE HARDWARE CLOTH 24 GAUGE WIRE MESH 0 WITH 1/4 INCH MESH OPENINGS. ri m z INSTALL 6 FT. SELF FASTENER ANGLE STEEL r POST 2 FT. DEEP MINIMUM. T i SPACE POST A MAXIMUM OF 3 FT. O In Z Dv �o D Z 0 z O ❑ T �0 m z 0 m 3 ft� VARIABLE -► * DIMENSION WIRE MESH z o� rr z B' MAX. WITH WIRE MAX. WITHOUT WIREI LOL R D O n 2 ft ¢¢LL U O CD T 22 m MIDDLE AND VERTICAL WIRES < H W r~LLo zxm.. po SHALL BE 12% GAUGE MIN. OO DD~> 9 y TOP AND BOTTOM STRAND SHALL BE 10 GAUGE MIN. icx ❑ n aiAlbAtI It WIRE FILTER FABRIC 2 LL UJ 4 Z N iz Lu O .( g NOTES USE WIRE A MINIMUM OF 32" FILTER FABRIC ---� MINIMUM ❑ J ❑ N d M o r IN WIDTH AND WITH A OF 6 LINE WIRES WITH 12" STAY COMPACTED FILL SPACING. a 4 s USE FLTER FABRIC A MINIMUM v~i .� OF 38"IN WIDTH AND FASTEN _. _ M z _ ADEQUATELY TO THE WIRE AS DI _ RECTED BY THE ENGINEER. V5 CL ii _jW m o PROVIDE 6'-0" STEEL POST OF THE W~ s SELF -FASTENER ANGLE STEEL TYPE. yLL = 06 STEEL POST - 2'-0" DEPTH 4° EXTENSION OF FABRIC AND WIRE INTO TRENCH NE ET 1 of 1 HEFT 1 OF 1 1606.01 1605.01 GENERAL NOTES: USE NO. 6 OR NO. 67 STONE FOR SEDIMENT to CONTROL STONE. USE HARDWARE CLOTH 24 GAUGE WIRE MESH 0 WITH 1/4 INCH MESH OPENINGS. ri m z INSTALL 6 FT. SELF FASTENER ANGLE STEEL r POST 2 FT. DEEP MINIMUM. T i SPACE POST A MAXIMUM OF 3 FT. O In Z Dv �o D Z 0 z O ❑ T �0 m z 0 m 3 ft� VARIABLE -► * DIMENSION WIRE MESH �- - S" MIN MATTING !HALL BE GTAlLES 0 PLACED IN TRENCH �� SEDIMENT CONTROL STONE 2 ft 1 ft min L4 WIRE MESH SEDIMENT CONTROL STONE 1 ft min . Q WATER FLOW —w 9 STEEL POST - 2 ft DEPTH 1i4 WIRE MESH J z rt z O N gg< LLJdN•Iz O COQ _ WQ LL= N LL O J CC, (/J > r> ❑ O W 0 z W o � LL J z � �a v a Z D W y N ($�J J W a M Q w a XQ MATTING INSTALLATION DETAIL (MIN. GROUND EACKFILL� 4 MATTING IN D=M 'XXi'tli'r9' °'tivi�;' �'• CENT11RI IN TRENCH �- - S" MIN MATTING !HALL BE GTAlLES 0 PLACED IN TRENCH �� 1' CENTER! AND SACKFIUAD IN TRENCH DIAGRAM AO MA7TWOQNSLOM DIAGRAM 1oru: T1I1 DOTAIL A Off TO fTAFYV, fIGiU:W� AND F511YUNflfi NIL ffINlp4f1EN1 WT (MANI IN{TA:SATIpI. rT u f1NLL 11 N°. 11 GIJfI R L MAf FOM INTO A 'U" f j WITN A PINI" T T YIOTN OF 1 INCH AID NOT LEU THAN f IN ER IN Ll11OiH. O 1d" WIRE MESH MoR�nn_> g�bm•.Q.o:.F 6 3' STAPLE � 3•� z O y \ N X D� MA7TWOQNSLOM DIAGRAM 1oru: T1I1 DOTAIL A Off TO fTAFYV, fIGiU:W� AND F511YUNflfi NIL ffINlp4f1EN1 WT (MANI IN{TA:SATIpI. rT u f1NLL 11 N°. 11 GIJfI R L MAf FOM INTO A 'U" f j WITN A PINI" T T YIOTN OF 1 INCH AID NOT LEU THAN f IN ER IN Ll11OiH. O 1d" WIRE MESH MoR�nn_> g�bm•.Q.o:.F PROJECT RFFERENCHEE E NO. ST NO. R-5707 EC3 STAPLE CHECK PATTERN STAPLE) 4 DIAGRAM O NOT T z O y • D� A o0 o� . Q 9 : o. O n A Y Y Z mr M MAXIMUM POST SPACING 4 FT. m 14' WIRE MESH °O' PROJECT RFFERENCHEE E NO. ST NO. R-5707 EC3 STAPLE CHECK PATTERN STAPLE) 4 DIAGRAM O NOT T M Z NOTE ❑ Z 2' USE N0. 6 OR N0. 67 STONE FL�YFLOW 2' F q FOR BEOIMENT CONTROL STONE. -► USE 24 GAUGE MINIMUM WIRE ,' ---- ❑ N �{ C SEDIMENT MESH HARDWARE CLOTH W27H SEDIMENT D CONTROL BTONE� 2' WIRE MESH 1/4 INCH MESH OPENINGS. CONT DL BTONFI H W N.1 * PLACE TOP OF WIRE MESH 1 W N A YINIYUY OF ONE FOOT BELOW y THE SHOULDER OR ANY J W DIVERSION POINT. INSTALL WIRE MESH UNDER AVERAGE BOX J o AVERAGE BOX SEDIMENT CONTROL $TONE. DIMENSION VARIABLE S DIMENSION VARIABLE USE 6' STEEL POST, INSTALLED 9 FILTERED 1.6' DEEP MINIMUM, AND FILTERED m WATER OF THE SELF -FASTENER WATER SECTION A A ANGLE STEEL TYPE. SECTION Y -Y O SPACE P06T A MAXIMUM 0. OF 4'. MULTI -DIRECTIONAL FLOW SINGLE -DIRECTIONAL FLOW z O y • F Y A Y Y 14' WIRE MESH °O' :p •' L4" WIRE MESH U a LLLL rQ SEE NOTE FOR POST DESCRIPTION = 06 .'. ❑ M Z NOTE ❑ Z 2' USE N0. 6 OR N0. 67 STONE FL�YFLOW 2' F q FOR BEOIMENT CONTROL STONE. -► USE 24 GAUGE MINIMUM WIRE ,' ---- ❑ N �{ C SEDIMENT MESH HARDWARE CLOTH W27H SEDIMENT D CONTROL BTONE� 2' WIRE MESH 1/4 INCH MESH OPENINGS. CONT DL BTONFI H W N.1 * PLACE TOP OF WIRE MESH 1 W N A YINIYUY OF ONE FOOT BELOW y THE SHOULDER OR ANY J W DIVERSION POINT. INSTALL WIRE MESH UNDER AVERAGE BOX J o AVERAGE BOX SEDIMENT CONTROL $TONE. DIMENSION VARIABLE S DIMENSION VARIABLE USE 6' STEEL POST, INSTALLED 9 FILTERED 1.6' DEEP MINIMUM, AND FILTERED m WATER OF THE SELF -FASTENER WATER SECTION A A ANGLE STEEL TYPE. SECTION Y -Y O SPACE P06T A MAXIMUM 0. OF 4'. MULTI -DIRECTIONAL FLOW SINGLE -DIRECTIONAL FLOW NCDOT B-5202 BEAUFORT COUNTY REPLACE BRIDGE NO.18 NC 99 (PUNGO RD) OVER INTERCEPTING CANAL BETWEEN SR 1625 AND SR 1629 CAMA GP, NWP 3, AND BUFFER AUTHORIZATION APPLICATION WBS ELEMENT NUMBER 45300.1✓ SCALE: 1'=30' (FULL—SIZE 22734') SCALE: 1e=60' (HALF—SIZE 117/7') MARCH 29, 2011 FOR PERMITTING ONLY: NOT FOR CONSTRUCTION C: BI COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. FILL REMOVAL = 106 Sq.Ft. Sl STREAM IMPACTS = 125 LINEAR Ft. S2 STREAM IMPACTS = 52 Sq.Ft. PILINGS IN CANAL BUFFER ZONE 1 IMPACTS = 510 Sq.Ft. BUFFER ZONE 2 IMPACTS = 320 Sq.Ft. -L- PI Sto 1311094 p = 0' 05' 41.3' (RT) D - 0' 04'03.6 L = 140J3' T = 70.06' R = 84b80DO' EXISTING R/W —T — _T_—T— T_ Y`t !47 45YE o NC HWY 99 20' BST 8°1fit G 350 ®_ F EXIS G R/W 0 15011641 R.H. BISHOP, JR., ET AL 643 WATER STREET BELHAVEN. NC 27810 DB 775 PG 2$3 816.27 AC r-\ �\—\ � \ \ I BUFFER ZONE 1 IMPACTS BUFFER ZONE 2 IMPACTS 404 WETLAND IMPACTS CULTIVATED FIELD I J I Q I Co I M ' ,S;�; 30, OIL _---� 20, I CL 0 -BLL 9+T 5� 1 EL=8.64' CAT -I m/ SHOP CURVE Bl {TYP) I \ 84 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq. Ft. S5 STREAM IMPACTS = 52 Sq. Ft. FILL REMOVAL = 128 Sq. Ft. BUFFER ZONE IIMPACTS = 501 Sq. Ft. BUFFER ZONE 2 IMPACTS = 346 Sq. Ft. N N � m Lo 82 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. S3 STREAM IMPACTS = 52 Sq. Ft. FILL REMOVAL = 70 Sq.Ft. BUFFER ZONE 1 IMPACTS = 2302 Sq.Ft. BUFFER ZONE 2 IMPACTS = 1513 Sq.Ft. BUFFER 2 ZONE I OP.E L30' ' 20. +4 \{/F- + ,� AN Sta 10473.56 -D- 1 in � lU PT Sta /0+39.47 PC - r.16+5633 —L— \� 43O — . ,n�nnnn _r)-', � I ' 1 a� $ESx h.1 d. DeeceipEiee 1605.01 High Vie Temporary .Milt Fence ----- 1606.01 Special Sediment Control Fence ------ 000000 1632.03 Rock Inlet Sediment Trap Type C_ _ _ _ _ _ _ _ _ _ u °o 000000 BUFFER 2 ZONE Q) BOER 'Z6NEER EXISTING BRIDGE R18 WOOD- PILING, STRINGERS,t HW/WW ON NORTHEAST ✓IDE CORUGATED STEEL HW/WW ON SOUTHWEST SIDE CONC RAILS, CROSS BEAMS, AND DECK BST PAVING �r -D- PI Sto I0+35.01 p = 45' 00'00.0' (LT) D = 4T7"27'53.4' L = 9.42' T - 497' R - 12-W 0 8 °� EXISTING R/W PROJECT— 9 30 15 0 30 60 �ry SCALE 0 15011641 R.H. BISHOP, JR., ET AL 643 WATER STREET BELHAVEN, NC 27810 DB 775 PG 283 816.27 AC CULTIVATED FIELD NC HW 99 20' 85T F B3 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. S4 STREAM IMPACTS = 52 Sq. Ft. FILL REMOVAL = 77 Sq. Ft. BUFFER ZONE IIMPACTS = 557 Sq. Ft. BUFFER ZONE 2 IMPACTS = 354 Sq.Ft. CULTIVATED FIELD 0 15011641 R.H. BISHOP. JR.. ET AL 643 WATER STREET BELHAVEN, NC 27810 DB 775 PG 283 816.27 AC NOTES: (I) B-5202 IS ON THE PANTEGO USGS QUAD MAP AND SHEET NUMBER 9 OF THE SOILS SURVEY OF BEAUFORT COUNTY (2) FIRM PANEL 6688 J, MAP NUMBER 3720668800 J (3) B-5202 IS IN THE TAR-PAMLICO RNER BASIN HUC CODE 03020104 (4) NO MORATORIUM AS PER TRAVIS WILSON. NCWRC NOVEMBER 19, 2009 (5) B-5202, BEAUFORT BRIDGE '60 IS CAMA JURISDICTIONAL AS PER STEPHEN LANE. NCDCM DECEMBER 4, 2009 _o (D V) 41 R.H. BISHOP, R., ET AL SIN 643 WATER STREET I� BELHAVEN, NC 27810 I DB 775 PG 283 U 816.27 AC BI COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. FILL REMOVAL = 106 Sq.Ft. Sl STREAM IMPACTS = 125 LINEAR Ft. S2 STREAM IMPACTS = 52 Sq.Ft. PILINGS IN CANAL BUFFER ZONE 1 IMPACTS = 510 Sq.Ft. BUFFER ZONE 2 IMPACTS = 320 Sq.Ft. -L- PI Sto 1311094 p = 0' 05' 41.3' (RT) D - 0' 04'03.6 L = 140J3' T = 70.06' R = 84b80DO' EXISTING R/W —T — _T_—T— T_ Y`t !47 45YE o NC HWY 99 20' BST 8°1fit G 350 ®_ F EXIS G R/W 0 15011641 R.H. BISHOP, JR., ET AL 643 WATER STREET BELHAVEN. NC 27810 DB 775 PG 2$3 816.27 AC r-\ �\—\ � \ \ I BUFFER ZONE 1 IMPACTS BUFFER ZONE 2 IMPACTS 404 WETLAND IMPACTS CULTIVATED FIELD I J I Q I Co I M ' ,S;�; 30, OIL _---� 20, I CL 0 -BLL 9+T 5� 1 EL=8.64' CAT -I m/ SHOP CURVE Bl {TYP) I \ 84 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq. Ft. S5 STREAM IMPACTS = 52 Sq. Ft. FILL REMOVAL = 128 Sq. Ft. BUFFER ZONE IIMPACTS = 501 Sq. Ft. BUFFER ZONE 2 IMPACTS = 346 Sq. Ft. N N � m Lo 82 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. S3 STREAM IMPACTS = 52 Sq. Ft. FILL REMOVAL = 70 Sq.Ft. BUFFER ZONE 1 IMPACTS = 2302 Sq.Ft. BUFFER ZONE 2 IMPACTS = 1513 Sq.Ft. BUFFER 2 ZONE I OP.E L30' ' 20. +4 \{/F- + ,� AN Sta 10473.56 -D- 1 in � lU PT Sta /0+39.47 PC - r.16+5633 —L— \� 43O — . ,n�nnnn _r)-', � I ' 1 a� $ESx h.1 d. DeeceipEiee 1605.01 High Vie Temporary .Milt Fence ----- 1606.01 Special Sediment Control Fence ------ 000000 1632.03 Rock Inlet Sediment Trap Type C_ _ _ _ _ _ _ _ _ _ u °o 000000 BUFFER 2 ZONE Q) BOER 'Z6NEER EXISTING BRIDGE R18 WOOD- PILING, STRINGERS,t HW/WW ON NORTHEAST ✓IDE CORUGATED STEEL HW/WW ON SOUTHWEST SIDE CONC RAILS, CROSS BEAMS, AND DECK BST PAVING �r -D- PI Sto I0+35.01 p = 45' 00'00.0' (LT) D = 4T7"27'53.4' L = 9.42' T - 497' R - 12-W 0 8 °� EXISTING R/W PROJECT— 9 30 15 0 30 60 �ry SCALE 0 15011641 R.H. BISHOP, JR., ET AL 643 WATER STREET BELHAVEN, NC 27810 DB 775 PG 283 816.27 AC CULTIVATED FIELD NC HW 99 20' 85T F B3 COASTAL WETLAND IMPACTS = 0 Sq.Ft. 404 WETLAND IMPACTS = 0 Sq.Ft. S4 STREAM IMPACTS = 52 Sq. Ft. FILL REMOVAL = 77 Sq. Ft. BUFFER ZONE IIMPACTS = 557 Sq. Ft. BUFFER ZONE 2 IMPACTS = 354 Sq.Ft. CULTIVATED FIELD 0 15011641 R.H. BISHOP. JR.. ET AL 643 WATER STREET BELHAVEN, NC 27810 DB 775 PG 283 816.27 AC NOTES: (I) B-5202 IS ON THE PANTEGO USGS QUAD MAP AND SHEET NUMBER 9 OF THE SOILS SURVEY OF BEAUFORT COUNTY (2) FIRM PANEL 6688 J, MAP NUMBER 3720668800 J (3) B-5202 IS IN THE TAR-PAMLICO RNER BASIN HUC CODE 03020104 (4) NO MORATORIUM AS PER TRAVIS WILSON. NCWRC NOVEMBER 19, 2009 (5) B-5202, BEAUFORT BRIDGE '60 IS CAMA JURISDICTIONAL AS PER STEPHEN LANE. NCDCM DECEMBER 4, 2009 A, 201111:03 'ROJE CTS\,tt3EA(J ORT\B5202\b5202-ddc2_xpl.dgn I EI ICED 0 r' 18+ 0 17 + 0. Q ' I 17+ 0 0 I 2- , i 2. \ 0 - - _ _ 0 - I I 7-715 -'' a. o X! J E r!5 . 0 14+ 0777 14+ 0 0 3 E tSF:. . .. - ... 13 + 00. 0 so R E rjr 55rsr 0 V. 01 i 1 +�- N G .. __ z i5t ZO _ 1�+L0:0 N x Z 70 _.. 60 ;. �o 30—t t 70 O,'ji 90 ROJEECTS \BEAUFORT\85202\ 5202_ddc2 pld9n NAM 'F B'SE EII EF !• 1D i{ I I I I . � I i I -11 91 -LLLJ — 10 + 3. '6 _ 10 + .j 0, 0 10 + 9: 7 _T 10+ 10. 04 9 10+ 1 3. 0 —777 o N fn rj EX sr a o _ . + 19 0: 0 x x m _.. I — --- Z O go J 1 _. _, 0 STA. 14+94.83 -L- FILL FACE END BENT 1 GRADE POINT EL. 12.129 15+00 FIX 15 10 11 "`ti. s 5 `" i 0 I I ON HP 12X53 -5 GALVANIZED STEEL PILES -10 PROPOSED - FACE Q END SHEET PILES END BENT 1 15+50 16+00 SPAN A SPAN B SPAN C FIX FIX FIX FIX UNCLASSIFIED STRUCTURE EXCAVATION (TYP.) EXISTING STRUCTURE L. 9,9'�IIIIIIf{f�II1I(II (TYP.) iiI RIIIIIIlI IIIIIlII �W S. ELEV. 05;;0 aR 3.0 + EIIIIIIJ II1III .o.. _. •••-•1III11II i1. I -••-• --•• F• ............ 2:1 SLOPE ICLASS II �'lo RIP RAP (• �/', RIIII, III PRESTRESSED CONCRETE CONCRETE PILES (TYP.) BENT 1 BENT 2 FIX II II APRROX. 3:1 SLOPE CLASS I: RIP RAF SHEET PILES STA. 16+17.33 -L- FILL FACE ENO BENT 2 GRADE POINT EL. 12.497 HP 12X53 GALVANIZED STEEL PILES 16+50 GRADE DATA +0.30007. ^ -0.7583% PI=16 55.00 EL.=12.61 VC=75' PROPOSED HP 12X53 SHEETING GALVANIZED STEEL PILES O 0° EXISTING ;%OMD ATTTFACECOFNNEL EXISTING SHEETING CLASS II RIP RAP FILTER FABRIC RIP RAP DETAIL NOT TO SCALE Q�J�O UNCLASSIFIED FQ� O STRUCTURE EXCAVATION Al (TYP.) oQ W.P. D BENT FACE STA. 16+17.33 _ L- SECTION ALONG -L- z z ON •♦♦.•♦•♦♦.•♦v�♦,EXCAVATED m - m v FACE Q END BENT STA. 14+94.83 ���r♦ �����������ow�� ♦1WEND APPROACH SLAB ►�����r♦ n Z D r 1 11 ����������i►r�� EXISTING 11Li/ STRUCTURES I (TYP.) I n II n � II II BEGIN APPROACH SLAB STA. 14+83.83 -L- I II W p I 11 II BRIDGE IDENTITY II STA.1 +36.02 -L- , STA. 15+56.08 -L- II 11 i II II 11 II 11 ►I II I � „ I1 11 . II 11 AREA TO BE EXCAVATED ON A 21 SLOPE U U AND RIP RAPPED I u FIX II II APRROX. 3:1 SLOPE CLASS I: RIP RAF SHEET PILES STA. 16+17.33 -L- FILL FACE ENO BENT 2 GRADE POINT EL. 12.497 HP 12X53 GALVANIZED STEEL PILES 16+50 GRADE DATA +0.30007. ^ -0.7583% PI=16 55.00 EL.=12.61 VC=75' PROPOSED HP 12X53 SHEETING GALVANIZED STEEL PILES O 0° EXISTING ;%OMD ATTTFACECOFNNEL EXISTING SHEETING CLASS II RIP RAP FILTER FABRIC RIP RAP DETAIL NOT TO SCALE Q�J�O UNCLASSIFIED FQ� O STRUCTURE EXCAVATION Al (TYP.) oQ W.P. D BENT FACE STA. 16+17.33 _ L- BENT i �- BENT 2 CONTROL LINE CONTROL LINE S E OPPILD S 20'-0-Y4' 20'-0Y4" 41 2'/4' 40'-1%2" 41'-2/4" S� TA �A Q� 122'-6"FILL FACE TO FILL FACE �T0 BENCHMARKMARK tiQlGti� �tec�+lo� NAIL SET IN PP 94� POS ON NW SIDE OF NC HWY 99 EXISTING PLAN cgO�i SEAL 104' LT. BL. STA. 9+25 SHEET PILES EL. 8.64 RTOOBED G1O �c� IpE� r~ c C4AptEs BY , M. D. IVY DATE 9/20/10 D BY , B. C. HUNT DATE 9/20/10 PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- REPLACES BRIDGE °18 ON •♦♦.•♦•♦♦.•♦v�♦,EXCAVATED ���r♦ �����������ow�� ♦1WEND APPROACH SLAB ►�����r♦ 11 ����������i►r�� 11Li/ BENT i �- BENT 2 CONTROL LINE CONTROL LINE S E OPPILD S 20'-0-Y4' 20'-0Y4" 41 2'/4' 40'-1%2" 41'-2/4" S� TA �A Q� 122'-6"FILL FACE TO FILL FACE �T0 BENCHMARKMARK tiQlGti� �tec�+lo� NAIL SET IN PP 94� POS ON NW SIDE OF NC HWY 99 EXISTING PLAN cgO�i SEAL 104' LT. BL. STA. 9+25 SHEET PILES EL. 8.64 RTOOBED G1O �c� IpE� r~ c C4AptEs BY , M. D. IVY DATE 9/20/10 D BY , B. C. HUNT DATE 9/20/10 PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- REPLACES BRIDGE °18 STRUCTURE NOTES FOR PILES, SEE SPECIAL PROVISIONS. PILES AT END BENT NO.1 & 2 ARE DESIGNED FOR A FACTORED RESISTANCE OF 59 TONS PER PILE. DRIVE PILES AT END BENT NO.1 & 2 TO A REQUIRED DRIVING RESISTANCE OF 100 TONS PER PILE. PILES AT BENT NO.1 & 2 ARE DESIGNED FOR A FACTORED RESISTANCE OF 110 TONS PER PILE. DRIVE EADDITIRESISTANCE FOR PILES AT ENT REQUIRED QUIRE AG OR SCOUR. ESISTANCE OF 200 TONS PER PILE. THIS REQUIRED DRIVING RESISTANCE INCLUDES INSTALL PILES AT BENT NO.1 & 2 TO A TIP ELEVATION NO HIGHER THAN -34.0. SCOUR CRITICAL ELEVATION FOR BENT NO.1 & 2 IS ELEVATION -13.0. SCOUR CRITICAL ELEVATIONS ARE USED TO MONITOR POSSIBLE SCOUR PROBLEMS DURING THE LIFE OF THE STRUCTURE. TESTING PILES WITH THE PILE DRIVING ANALYZER (PDA)DURING DRIVING, RESTRIKING. OR REDRIVING MAY BE REQUIRED. THE ENGINEER WILL DETERMINE THE NEED FOR PDA TESTING. FOR PILE DRIVING ANALYZER, SEE PILES SPECIAL PROVISION. SHEET PILES AT END BENT NO.1 & 2 SHALL BE DRIVEN BEFORE INSTALLING PILES. WHERE LOCATFOR ED INSTEETC PILE LAND ABUTMENT OUTSIDE OF BENT NO. I THE END BENTECAP BE DRIVEN TO A TIP ELEVATION NO HIGHER THAN -18.000 SHEET PILES FOR SHEET PILE ABUTMENT WALL AT END BENT NO.2 ARE TO BE DRIVEN TO A TIP ELEVATION NO HIGHER THAN -12.000. THIS BRIDGE HAS BEEN DESIGNED IN ACCORDANCE WITH HEC 1B. 'EVALUATING SCOUR AT BRIDGES. MAY ,2001. NO WAITING PERIOD IS REQUIRED FOR END BENT CONSTRUCTION AFTER COMPLETION OF EMBANKMENT. REMOVAL OF THE EXISTING BRIDGE SHALL BE PERFORMED SO AS NOT TO ALLOW DEBRIS TO FALL INTO THE WATER AND IN ACCORDANCE WITH ARTICLE 402-2 OF THE STANDARD SPECIFICATIONS. THE EXISTING STRUCTURE CONSISTS OF 6 SPANS (18'-8",4 Q 17'-0.18-6').THE SUPERSTRUCTURE CONSISTS OF A REINFORCED CONCRETE DECK COVERED WITH ASPHALT ON TIMBER JOISTS. THE SUBSTRUCTURE CONSISTS OF ONE END BENT WITH A CONCRETE CAP, TIMBER PILES AND SHEET PILES AND ONE END BENT WITH A CONCRETE CAP AND TIMBER PILES. THE BENTS CONSIST OF CONCRETE CAPS, TIMBER PILES AND STEEL CAPS AND TIMBER PILE CRUTCH BENTS. THE EXISTING STRUCTURE SHALL BE REMOVED. THE EXISTING SHEET PILES SHALL ALSO BE REMOVED. THE SUBSTRUCTURE OF THE EXISTING BRIDGE INDICATED ON THE PLANS IS FROM THE BEST INFORMATION AVAILABLE. SINCE THIS INFORDEPART(MENTT OFSSHOWN FOR THE TRANSPORTTATION FORVANYENCE DELADF THE YS OR ADDITIONALR,THE CONTRACTOR COST INCURRED BASEDL HAVE NO CLAIM ON DIFFERENCES BETWEEN VER AGAINST THE THE THE EXISTING BRIDGE SUBSTRUCTURE SHOWN ON THE PLANS AND THE ACTUAL CONDITIONS AT THE PROJECT SITE. ASSUMED LIVE LOAD = HL -93 OR ALTERNATE LOADING. FOR OTHER DESIGN DATA AND GENERAL NOTES, SEE SHEET SN. FOR EROSION CONTROL MEASURES.SEE EROSION CONTROL PLANS. THIS BRIDGE HAS BEEN DESIGNED IN ACCORDANCE WITH THE AASHTO LFRD BRIDGE DESIGN SPECIFICATION. THIS BRIDGE CONTAINS THE NECESSARY PROTECTION REQUIRED FOR A CORROSIVE SITE. FOR SUBMITTAL OF WORKING DRAWINGS. SEE SPECIAL PROVISIONS. FOR CRANE SAFETY. SEE SPECIAL PROVISIONS. FOR PRESTRESSED CONCRETE MEMBERS, SEE SPECIAL PROVISIONS. FOR GROUT FOR STRUCTURES.SEE SPECIAL PROVISIONS. FOR CURING CONCRETE, SEE SPECIAL PROVISIONS GALVANIZE THE TOP 25 FEET OF ALL PILES IN ACCORDANCE WITH SECTION 1076 OF THE STANDARD SPECIFICATIONS. FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS. CLASS AA CONCRETE SHALL BE USED IN ALL CAST IN PLACE END BENT AND BENT CAPS AND SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. ALL PRESTRESSED CONCRETE CORE SLAB UNITS AND PRESTRESS PILES SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. THE MATERIAL SHOWN IN THE CROSS -HATCHED AREA ON SHEET S-1 SHALL BE EXCAVATED AS SHOWN OR AS DIRECTED BY THE ENGINEER. THIS WORK WILL BE PAID FOR AT THE CONTRACT LUMP SUM PRICE FOR UNCLASSIFIED STRUCTURE EXCAVATION. SEE SECTION 412 OF THE STANDARD SPECIFICATIONS. ALL BAR SUPPORTS USED IN THE BARRIER RAIL. BENT CAPS AND ALL INCIDENTIAL REINFORCING STEEL SHALL BE EPDXY COATED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. FOR 18"GALVANIZED STEEL SHEET PILES. SEE SPECIAL PROVISIONS. HYDRAULIC DATA STRUCTURE TOTAL BILL OF MATERIAL REMOVAL OF POA EXISTING TESTING STRUCTURE PDA ASSISTANCE UNCLASSIFIED STRUCTURE EXCAVATION CLASS AA CONCRETE BRIDGE EPDXY APPROACH COATED SLABS REINFORCING STEEL HP 12X53 GALVANIZED STEEL PILES 16"PRESTRESSEO CONCRETE PILES PILE EDRIVES VERTICAL CONCRETE BARRIER RAIL RIP RAP CLASS II (2'-O"THICK) FILTER FABRIC FOR DRAINAGE ELASTOMERIC BEARINGS 3'-0"X V-9" PRESTRESSED CONC.CORED SLABS 18"GALVANIZED STEEL SHEET PILES LUMP SUM EACH EACH LUMP SUM CU. YDS. LUMP SUM LBS. NO. LIN. FT. NO. LIN. FT. EACH LIN. FT. TONS SO. YDS. LUMP SUM LIN. FT. S0. FT. SUPERSTRUCTURE LUMP SUM LUMP SUM 240.75 LUMP SUM 1320.00 END BENT '1 17.6 2465 7[q7 4 125 140 3307 BENT '1 10.3 2122 455 4 BENT '2 10.3 2122 455 4 END BENT '2 17.6 2465 7 420 4 130 145 1386 TOTAL LUMP SUM I 1 LUMP SUM 55.8 LUMP SUM 9174 14 875 14 910 16 240.75 255 285 LUMP SUM 1320.00 4693 DESIGN DISCHARGE = 3400 c.f.s. FREQUENCY OF DESIGN FLOOD = 25 YRS. DESIGN HIGH WATER ELEVATION = 9.8 DRAINAGE AREA = 66.8 SO. MI. BASIC DISCHARGE (0100) = 4610 c.f.s. BASIC HIGH WATER ELEVATION - 12.4 OVERTOPPING FLOOD DATA OVERTOPPING DISCHARGE = 3700 c.f.s. FREQUENCY OF OVERTOPPING FLOOD = 50- YRS. OVERTOPPING FLOOD ELEVATION = 10.6 ��tN CAADLGy' �pE t CYARIES j/ PROJECT NO. 8-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- TIE PROPOSED SHEETING INTO EXISTING BANK END OF EXISTING I l TOP OF BANK SHEET PILES 75' ± ,TOP OF TOP OF SHEETING GROUNDFL, .300 PROPOSED—,-DIST.VARIES SHEET FROM, O' TO PILES APPROX. O L EXISTING fOEMD BOT. OF CHANNEL AT FACE OF EXISTING SHEETING, CLASS II RIP RAP 2:1 EXCAVATED SLOPE SECTION A -A PROPOSED SHEETING -1 24°' -00' - BEGIN APPROACH SLAB STA. 14+83.83 -L- W.P. "1 FILL FACE Q END BENT 1 STA. 14+94.83 -L- PROPOSED SHEETING? PLACE CLASS II RIP RAP ON ALL EXCAVATED SLOPES A PROPOSED SHEETING A TIE PROPOSED SHEETING INTO EXISTING BANK w / / _ _ CHANNEL C / - EDGE EXISTING y AREA TO BE SHEET PILES LA EX2:IVSLOPETO AND RIP RAPPED -L- 1------------- ------------, REMOVE ALL EXISTING SHEET ��SN C+Uta[ib AL 9 e� CI XE� Jr� CVAP.LES PROJECT N0. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- 0 0 0 LRFR SUMMARY FOR SPANS A,B AND C LOAD FACTORS: DESIGN LOAD RATING LIMIT STATE YDc Ypw RESISTANCE FACTOR RATING (LRFD) SUMMARY FOR FRES I RE55tU �,Ul%-t L I t UlrF L)EFZJ LOAD AND STRENGTH I LIMIT STATE SERVICE III LIMIT STATE MOMENT SHEAR MOMENT z � Ln ¢ LL K o 0O Z O H �- O Zp Q ¢ w m m (,L3 O H Z OLL H O U Q U Q LL LL O OH4 O U U 0 .-. „-� LLO U UO LL O Z Z Z H H U Q X H O Q W O "' H U'n Q LL O J W O ,f, O � cc LnU LL J w 0+ Z H J Q m� U O Z Zwt m N ro U Zww < tn O� H Q 0:0 U Z W Z W Q Z W J H _ O D: Z i i K O f- Z H Z W O a H H Z cr O H /- Z H Z W 4 Q H Z W O > U H H �'-� r Z Q Q: H H Z N w a J Lu H V Z Ho H 0 za �'-� H H�-LL N z W H H Na H a a D: �-+ N LL Q Hwd N U H < H a Q a D: H L LL Q Hwa Ha H C O LL a d N H V H W d O J V7 O U > w = W w H 3... O O U J a'r �.- H r>ia JLL H OLL a G: Ln C) D Jln DLL Q: N U O JN JLL J y 1.319 -- 1.75 0.278 1.76 40' EL 19.5 0.549 1.32 40' EL 1.95 0.80 0.278 1.55 40' EL 19.5 HL 93(Inv) N/A 1 0.549 1.71 40' EL 1.95 N/A - - - - 0.278 2.28 40' EL 19.5 N/A -- 1.709 - 1.35 0.549 1.54 40' EL 1.95 0.80 0.278 1.94 40' EL 1 . DESIGN HL-93(Opr) 0.278 2.21 40' EL 19.5 LOAD HS 2O(Inv) 36.000 2 1.54 55.449 1.75 "- RATING HS 20(Oprl 36.000 1.997 71.878 1.35 0.278 2.86 40' EL 19.5 0.549 2 40' EL 1.95 N/A - 3.606 48.687 1.4 0.278 5.1 40' EL 19.5 0.549 4.13 40' EL 1.95 0.80 0.278 3.61 40' EL 19.5 SLASH 13.500 0.278 4.19 40' EL 15.6 0.549 3.07 40' EL 1.95 0.80 0.278 2.96 40' EL 19.5 1.4 SNGARBS2 20.000 - 2.964 59.289 EL 15.6 0.549 2.91 40' EL 1.95 0.80 0.278 2.92 40 EL 15.6 SNAGRIS2 22.000 2.906 63.929 1.4 0.278 4.09 40' EL 19.5 27.250 1.803 49.125 1.4 0.278 2.55 40' EL 19.5 0.549 2.07 40' EL 1.95 O.BO 0.278 1.80 40' SNCOTT53 40' EL 19.5 0.549 1.82 40' EL 1.95 0.80 0.278 1.62 40' EL 19.5 N SNAGGRS4 34.925 1.623 56.667 1.4 0.278 2.29 EL 19.5 35.550 1.578 56.107 1.4 0.278 2.23 40' EL 19.5 0.549 1.9 40' EL 1.95 0.80 0.278 1.58 40' SNS5A 1.502 59.992 1.4 0.278 2.12 40' EL 19.5 0.549 1.77 40' EL 1.95 0.80 0.278 1.50 40' EL 19.5 SNS6A 39.950 EL 19.5 0.549 1.81 40' EL 1.95 0.60 0.278 1.43 40' EL 19.5 SNS78 42.000 3 1.432 60.149 1.4 0.278 2.02 40' 1 0.549 2.08 40' EL 1.95 0.80 0.278 I.BS 40' EL 19. LEGAL 0.278 2.61 40' EL 19.5 -- 1.848 60.976 1.4 LOAD TNAGRIT3 33.000 EL 19.5 0.549 1.98 40' EL 1.95 0.80 0.278 1.87 40' EL 19.5 RATING TNT4A 33.075 1.872 61.901 1.4 0.278 2.651 40' 1.587 66.032 1.4 1 0.278 2.24 1 40' EL 19.5 0.549 1.94 40' EL 1.95 0.80 0.278 1.59 40' EL 19.5 TNTGA 41.600 40' EL 19.5 0.549 1.79 40' EL 1.95 0.80 0.278 1.63 40' EL 19.5 - TNT7A 42.000 1.627 68.354 1.4 0.278 2.3 0.549 1.72 40' EL 1.95 0.80 0.278 1.66 40' EL 19.5 0.278 2.35 40' EL 19.5 42.000 1.664 69.888 1.4 TNT78 1.619 69.61 1.4 0.278 2.28 40' EL 15.6 0.549 1.65 40' EL 1.95 0.80 0.278 1.62 40' EL 19.5 TNAGRIT4 43.000 EL 19.5 0.549 1.71 40' EL 1.95 0.80 0.278 1.50 40' EL 19.5 TNAGTSA 45.000 .498 67.412 1.4 0.278 2.12 40' EL 19.5 45.000 Fl,455 65.486 1.4 0.278 2.06 40' EL 19.5 0.549 1.56 40' EL 1.95 0.80 0.276 1.46 40' TNAGT58 0 0 0 LRFR SUMMARY FOR SPANS A,B AND C LOAD FACTORS: DESIGN LOAD RATING LIMIT STATE YDc Ypw STRENGTH I 1.25 1.50 FACTORS SERVICE III 1.00 1.00 NOTES: MINIMUM RATING FACTORS ARE BASED ON THE STRENGTH I AND SERVICE III LIMIT STATES. ALLOWABLE STRESSES FOR SERVICE III LIMIT STATE ARE AS REOUIRED FOR DESIGN. COMMENTS: 1. 2. 3. Q CONTROLLING LOAD RATING O1 DESIGN LOAD RATING (HL -93) O2 DESIGN LOAD RATING (HS -20) O3 LEGAL LOAD RATING SEE CHART FOR VEHICLE TYPE GIRDER LOCATION I INTERIOR GIRDER EL - EXTERIOR LEFT GIRDER ER EXTERIOR RIGHT GIRDER SEAL 40 dC11{5. 'yC41AP.lEa� PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- 33'-0' 30'-10"(CLEAR ROADWAY) 15-5" 15-5" VERTICAL CONCRETE BARRIER RAIL (TYP.) L FOR DETAILS SEE "VERTICAL 7"(A (� BRG. CONCRETE BARRIER RAIL SECTION" 3'/q" ca � BRG. /r --/4"Q � BRG. ASPHALT WEARING GRADE PT. SURFACE (SEE o m � ROADWAY PLANS) ' 0.02 0.02 \-- 0.6'0 L.R. TRANSVERSE POST -TENSIONING STRAND 0" IN 21/2-0 HOLE 16'-6" SHEAR KEYS TO BE FILLED WITH GROUT AFTER ALL ERECTION HAS BEEN COMPLETED AND AFTER FINAL TENSIONING OF TRANSVERSE STRANDS 16'-6" 11 PRESTRESSED CONCRETE CORED SLAB UNITS = 33'-0" HALF SECTION HALF SECTION AT INTERMEDIATE DIAPHRAGMS TYPICAL SECTION THROUGH VOIDS *-THE MAXIMUM BARRIER RAIL HEIGHT AND ASPHALT THICKNESS IS SHOWN. THE HEIGHT OF THE BARRIER RAIL AND ASPHALT THICKNESS VARIES WHILE THE TOP OF THE BARRIER RAIL FOLLOWS THE PROFILE OF THE GUTTERLINE. FOR RAIL HEIGHT DETAILS AND ASPHALT THICKNESS SEE THE "VERTICAL CONCRETE BARRIER RAIL SECTION" DETAIL. FIXED END FIXED END FIXED END JT. ATBENT AC JT. END BENT 11/2" JT. 11/ " JT. AT BENT ASPHALT ASPHALT WEARING IIWEARING IF �21/z" DOWEL HOLES SURFACE X21/2" 0 DOWEL HOLE SURFACE -I 12" 0 GROUT6 APPROACH SLAB"•- VOIDS -. 1'-0" - - SEE "BRIDGE �----""-- Q SHEET FOR QETAILS - iO 2 LAYERS OF 30 LB. IQ - ROOFING FELT TO PREVENT BOND. j I ELASTOMERIC 2"0 BACKER ROD - _ ) BEARING PAD BEARING SEE "END BENT" & 6 DOWELS SHEETS FOR DETAILS SECTION AT END BENT (� 0.6" 0 L.R. TRANSVERSE HOLE FOR POST -TENSIONING STRAND TRANSVERSE STRAND SHEATHED WITH A NON -CORROSIVE PIPE. iL 4' 4" B g- B OUTSIDE FACE OF EXTERIOR I/,.• 5i CORED SLAB I X 5" X 5" Q STRAND VISE —FILL RECESS ,/,,WITH GROUT GROUT --I 12" 0 - - VOIDS ELASTOMERIC-'. BEARING PAD j 2'0 BACKER ROD 1'-6" 1'-6" 1" 10" 1'-4" 10" 3" 11„ 4" 4" 11" 3" 3'-0" j I 12" 3 VOIDS •5 53 3%" CL. Il / * •4 'B' o I m 3„ N I N —CONST. JT. ; (TYP.) •4 S2• • • •. ♦♦♦ ♦ o N — 7" TuI 2 SPA. 4 SPA. 2 SPA. _ o •4 S2 Q 2"CTS. 2'CTS. (d 2"CTS. s` ''`'':' . STRAND LAYOUT FOR 25'. 30' & 35' UNIT " 0 VOIDS (9 STRANDS REQUIRED) A3- 12 3 N 3-0" EXTERIOR SLAB SECTION 1'-6" 1'-6" ( FOR PRESTRESSED STRAND LAYOUT. SEE 10" I'-4" 10" INTERIOR SLAB SECTION.) 3" 11" 4" 4" 11" 3" •4 B I I 'll' 0 VOIDS BOND SHALL BE BROKEN ON THESE STRANDS FOR A DISTANCE OF 6'-0"FROM END OF CORED SLAB UNIT. `v SEE STANDARD SPECIFICATIONS. ARTICLE 1078-7. + i – •4 S2 o ® •�• m 7 7 �N N 2 SPA. 4 SPA. 2 SPA. CJ 2'CTS. CJ 2'CTS. CO 2"CTS. STRAND LAYOUT FOR 40'& 45' UNIT (13 STRANDS REQUIRED) 12" 0 ----- VOIDS l� aT - -- -- Lo I `-1-ELASTOMERIC BEARING - I BEARING PAD & •6 DOWELS - SEE "BENT" SHEETS FOR DETAILS SECTION AT BENT NL: •5 SI 3'-0" q 21/2" 0 SDOWEL HOLES 3/ate •5 Sl •4 "B" ELEVATION VIEW SECTION B -B '':., GROUTED RECESS AT END OF N, •5 S1 POST -TENSIONED STRAND OF CORED SLABS END ELEVATION SHOWING PLACEMENT OF DOUBLE STIRRUPS ASSEMBLED BY M. D. IVY DATE: AND LOCATION OF DOWEL HOLES. CHECKED BY : B. C. HUNT DATE , 9/20/10 (STRAND LAYOUT NOT SHOWN.) INTERIOR SLAB UNIT SHOWN -EXTERIOR SLAB DRAWN BY, DGE 3/09 UNIT SIMILAR EXCEPT SHEAR KEY LOCATION. CHECKED BY , BCH 3/09 I 3'-0" 10" 1'-4" 10" 3" 11" 4" 4" 11" 3" -4 712" 0 VOIDS N :: -+ + 1 Q O _ + I N o •4 S2 ®�® 3" 7" 7„I z,. IN 2 SPA. 4 SPA. 2 —SPA. 0 2" CTS. Q 2" CTS. Q 2" CTS. STRAND LAYOUT FOR 50'& 55' UNIT E�,- SHEAR KEY DETAIL NOTE: OMIT SHEAR KEY ON OUTSIDE FACE OF EXTERIOR CORED SLABS. (19 STRANDS REQUIRED) INTERIOR SLAB SECTION 0.6"0 LOW RELAXATION ❑• BOND SHALL BE BROKEN ON THESE STRANDS FOR A DISTANCE OF 2'-0"FROM END OF CORED SLAB UNIT, SEE STANDARD SPECIFICATIONS, ARTICLE 1078-7. OPTIONAL TTHESESTRANDS ARE GNOT REOUDIRDED.TIFNTOHE FABRICATOR CHOOSES TO INCLUDE THESE STRANDS IN THE CORED SLAB UNIT,THE STRANDS SHALL BE DEBONDED FOR THE FULL LENGTH OF THE UNIT AT NO ADDITIONAL COST. SEE STANDARD SPECIFICATIONS. ARTICLE 1078-7, DEBONDING LEGEND PROJECT NO. 8-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- (EET 1 OF 3 STATE OF l TH UROLI DEPARTMENT OF TRANSPORTATION MECK STANDARD 3'-0" X Y-9" PRESTRESSED CONCRETE CORED SLAB UNIT 900 SKEW REVISIONS SHEET NO. BY, I GATE, BY, DATE) S-5 { TOTAL U131 LEETS 18 20'-0" 20'-0" SEE DETAIL "A"—/ 1'-0" 2%2" PLAN OF UNIT 1'-0" 21/2" -00'-00" 1'-0' 7-•4 S2 PAIRS Q •4 S2 PAIRS 9'CTS. (Z 1'-O'CTS. 6" (� 211/z" 0 DOWEL HOLES I -CL. --------------- 12" ( -- -12" 0 VOIDS oz 2 •5 SI ` ---------------- - ------------ PROJECT -- --- - 8-•5 S3 W 6 -CTS. •5 S3 CJ 1' -0 -CT 3'-0' 3'/a" DETAIL "A" NOTE:EXTERIOR UNIT SHOWN - INTERIOR UNIT SIMILAR EXCEPT OMIT •5 S3 BARS. A CAR01,�'� EAC 091 �CYARLEsa PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 2 OF 3 VCR1 HAL l.U1Vl,Kt 11 YCR 1 1LAL UUIXURL I C BARRIER RAIL MATL.IN RAIL BARRIER RAIL (TYPJ 42-14 S2 PAIRS (SPACED AS SHOWN IN DETAIL "A") (TYP.EA. UNIT) 49-•5 S3 (SPACED AS SHOWN INDETAIL"A")(TYP.EA. EXT. UNIT) 49-•5 S4 (SPACED TO MATCH S3 IN VERTICAL CONCRETE BARRER RAIL) 20'-0" 20'-0' 40'-0" PLAN OF UNIT 1'-0" 21/2" -00'-00" 1'-0' 7-•4 S2 PAIRS Q •4 S2 PAIRS 9'CTS. (Z 1'-O'CTS. 6" (� 211/z" 0 DOWEL HOLES I -CL. --------------- 12" ( -- -12" 0 VOIDS oz 2 •5 SI ` ---------------- - ------------ PROJECT -- --- - 8-•5 S3 W 6 -CTS. •5 S3 CJ 1' -0 -CT 3'-0' 3'/a" DETAIL "A" NOTE:EXTERIOR UNIT SHOWN - INTERIOR UNIT SIMILAR EXCEPT OMIT •5 S3 BARS. A CAR01,�'� EAC 091 �CYARLEsa PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 2 OF 3 4' Ln —C BEARING PAD C 1"0 HOLES BEARING PAD - TYPE I - FIXED END ( TYPE I - 66 REO' D ) ELASTOMERIC BEARING DETAILS ELASTOMER IN ALL BEARINGS SHALL BE 50 DUROMETER HARDNESS. z N1 10" 1" m o L4 H 2" CL. MIN. II ~w SLABS REQUIRED ONE J J am 40' UNIT 0.6"PJ L.R. STRAND =a 6 40'-0" 240.00 INTERIOR C.S. L� Ln; TOTAL 33 1320.00 B4 4 '4 STR 20'-9" 55 w = z U H H N Tr c0 1" Q Lx S1 8 '5 3 4'-3" w 4'-3" 35 OH J H H m 299 l L-)< L D U � N CU.YDS. 24.6 TOTAL VERTICAL CONCRETE BARRIER RAIL Wo LN.FT. 240.50 N N D W Nz REINFORCING STEEL W Y H V 369 e � H EPDXY COATED REINFORCING STEEL LBS. a= 6500 P.S.I. CONCRETE CU. YDS. m 5.8 I CONST. JT. '5 S4 2" (TYP.) �'5 S3 - o �W a 2%' CL. N O 3%' r� GRADE 270 STRANDS 0.6" 0 L.R. AREA (SQUARE INCHES ) 0.217 ULTIMATE STRENGTH 58,600 (LBS. PER STRAND ) APPLIED PRESTRESS 43.950 ( LBS. PER STRAND ) CORED SLABS REQUIRED ONE NUMBER LENGTH OTAL LENGTH 40' UNIT 0.6"PJ L.R. STRAND EXTERIOR C.S. 6 40'-0" 240.00 INTERIOR C.S. 27 40'-0" 1080.00 TOTAL 33 1320.00 DEAD LOAD DEFLECTION AND CAMBER ONE 3'-0" x 1'-9" 40'& 45' CORED SLAB UNIT 0.6"PJ L.R. STRAND CAMBER ( SLAB ALONE IN PLACE 1 11/4' 4 DEFLECTION DUE TO SUPERIMPOSED DEAD LOAD /8 + FINAL CAMBER 11/B" 4 IM LVULUUtJ rU1U11t WtANINU �,UKh Agit CONCRETE RELEASE STRENGTH FOR UNIT ONE UNIT PSI 25'. 30' & 35' UNITS 4000 40'& 45' UNITS 4000 50'& 55' UNITS 4900 [ '12- EXP. JT. MAT'L HELD IN PLACE WITH GALVANIZED NAILS. ( NOTE: OMIT EXP. JT. MAT'L. WHEN SLIP FORM IS USED. OPEN JT.IN--V-'. AIL lJ BENT Ln J W Q H U cr H Q w � > H 0 15 S3 (SEE "PLAN OF UNIT" FOR SPACING) Y4' 11 CHAMFER CONST. J ELEVATION AT EXPANSION JOINTS VERTICAL CONCRETE BARRIER RAIL SECTION ASSEMBLED BY I M. D. IVY DATE i 9/20/10 CHECKED BY : B. C. HUNT DATE : 9/20/10 DRAWN BY .OGE 5/09 CHECKED BY BCH 6/09 BAR TYPES 7- 6" N 7 h" S1 1'-9" O rn v ALL BAR DIMENSIONS ARE OUT TO OUT BILL OF MATERIAL 40' CORED SLAB FOR UNIT ONE BAR BARS PER PAIR OF EXTERIOR UNITS TOTAL NO. SIZE TYPE I LENGTH EXTERIOR UNIT INTERIOR UNIT BAR NUMBER SIZE TYPE LENGTH WEIGHT LENGTH WEIGHT B4 4 '4 STR 20'-9" 55 20'-9" 55 1961 1" 2'-9'4" S1 8 '5 3 4'-3" 35 4'-3" 35 S2 84 '4 3 5'-4" 299 5-4" 299 S3 49 '5 1 6'-2" 315 CU.YDS. 24.6 TOTAL VERTICAL CONCRETE BARRIER RAIL LN.FT. 240.50 REINFORCING STEEL LBS. 369 389 EPDXY COATED REINFORCING STEEL LBS. 315 6500 P.S.I. CONCRETE CU. YDS. 5.8 5.8 0.6" 0 L.R. STRANDS No. 13 13 NOTES ALL PRESTRESSING STRANDS SHALL BE 7 -WIRE LOW RELAXATION GRADE 270 STRANDS AND SHALL CONFORM TO AASHTO M203 EXCEPT FOR SAMPLING REOUIREMENTS WHICH SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. ALL REINFORCING STEEL CAST WITH THE CORED SLAB SECTIONS SHALL BE GRADE 60 AND SHALL BE INCLUDED IN THE UNIT PRICE BID FOR PRESTRESSED CONCRETE CORED SLABS. RECESSES FOR TRANSVERSE STRANDS SHALL BE GROUTED AFTER THE TENSIONING OF THE STRANDS. THE 21/2"0 DOWEL HOLES AT FIXED ENDS OF SLAB SECTIONS SHALL BE FILLED WITH NON -SHRINK GROUT. THE 2'0 BACKER ROD SHALL CONFORM TO THE REOUIREMENTS OF TYPE M BOND BREAKER, SEE SECTION 1028 OF THE STANDARD SPECIFICATIONS. WHEN CORED SLABS ARE CAST.A POSITIVE HOLD-DOWN SYSTEM SHALL BE EMPLOYED TO PREVENT VOIDS FROM RISING OR MOVING SIDEWAYS. THIS SYSTEM SHALL BE DESIGNED TO BE LEFT IN PLACE UNTIL THE CONCRETE HAS REACHED RELEASE STRENGTH. AT LEAST THREE WEEKS PRIOR TO CASTING CORED SLABS, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR REVIEW AND COMMENT, DETAILED DRAWINGS OF THE PROPOSED HOLD-DOWN SYSTEM. IN ADDITION TO STRUCTURAL DETAILS, LOCATION AND SPACING OF THE HOLD-DOWNS SHALL BE INDICATED. ALL REINFORCING STEEL IN THE VERTICAL CONCRETE BARRIER RAIL SHALL BE EPDXY COATED. PRESTRESSING STRANDS SHALL BE CUT FLUSH WITH THE CORED SLAB UNIT ENDS. APPLY EPDXY PROTECTIVE COATING TO CORED SLAB UNIT ENDS. GROOVED CONTRACTION JOINTS, V2- IN DEPTH, SHALL BE TOOLED IN ALL EXPOSED FACES OF THE BARRIER RAIL AND IN ACCORDANCE WITH ARTICLE 825-10(B)OF THE STANDARD SPECIFICATIONS.A CONTRACTION JOINT SHALL BE LOCATED AT EACH THIRD POINT BETWEEN BARRIER RAIL EXPANSION JOINTS. ONLY ONE CONTRACTION JOINT IS REOUIRED AT MIDPOINT OF BARRIER RAIL SEGMENTS LESS THAB 20 FEET IN LENGTH AND NO CONTRACTION JOINTS ARE REQUIRED FOR THOSE SEGMENTS LESS THAN 10 FEET IN LENGTH. TRANSVERSE POST TENSIONING OF THE CORED SLAB UNITS SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS.EXCEPT THAT THE STRANDS SHALL BE 0.6"0 AND TENSIONED TO 43,950 POUNDS. THE TRANSFER OF LOAD FROM THE ANCHORAGES TO THE CORED SLAB UNIT SHALL BE DONE WHEN THE CONCRETE HAS REACHED A COMPRESSIVE STRENGTH OF NOT LESS THAN THE REOUIRED STRENGTH SHOWN IN THE "CONCRETE RELEASE STRENGTH" TABLE. FOR GROUT FOR STRUCTURES, SEE SPECIAL PROVISIONS. FOR VERTICAL CONCRETE BARRIER RAIL. SEE SPECIAL PROVISIONS. PRESTRESSED CONCRETE CORED SLAB UNITS SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. BILL OF MATERIAL FOR VERTICAL CONCRETE BARRIER RAIL BAR BARS PER PAIR OF EXTERIOR UNITS TOTAL NO. SIZE TYPE I LENGTH WEIGHT 40' UNIT Q MID -SPAN NORMAL CROWN SECTION 25'. 30' & 35' UNITS 2%B' 2'-11%' * Bll 32 96 '5 STR 19-7" 1961 1" 2'-9'4" S4 98 294 '5 2 5'-6" 1687 EPDXY COATED REINFORCING STEEL LBS. 3648 CLASS AA CONCRETE CU.YDS. 24.6 TOTAL VERTICAL CONCRETE BARRIER RAIL LN.FT. 240.50 GUTTERLINE ASPHALT THICKNESS & RAIL HEIGHT 30'-10"CLEAR ROADWAY ASPHALT OVERLAY THICKNESS: RAIL HEIGHT Q MID -SPAN Q MID -SPAN NORMAL CROWN SECTION 25'. 30' & 35' UNITS 2%B' 2'-11%' 40' & 45' UNITS 21/8' 2'-103/a- 50' & 55' UNITS 1" 2'-9'4" PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 3 OF 3 STATE D: NMT" C�LNA DEPARTMENT OF TRANSPORTATION RAEE,GN STANDARD 3'-0" X 1'-9" PRESTRESSED CONCRETE CORED SLAB UNIT ���4 `�0`'y, 900 SKEW At REVISIONS SHEET NO. �GCr INE��� BT, DATE. NO BT DATET S-7 CbARLE 11 131Tv[lls "�....» s I ft 18 GUARDRAIL CHOR ASSEI C 1'/6" 0 HOLES ( '/,' HOLD -DOM '/q" HOLD -DON PLAN C GUARDRAIL ANCHOR ASSEMBLY SECTION E -E GUARDRAIL ANCHOR ASSEMBLY DETAILS FOR LOCATION OF GUARDRAIL ANCHOR ASSEMBLY, SEE "PLAN" BELOW JT. @ — END BENT FINISH GRADE � JT. END BENT L_ rE 44" { I _4.. T I GUARDRAIL ANCHOR ASSEMBLY m L+ E ELEVATION PLAN LOCATION OF ANCHORS FOR GUARDRAIL END BENT '1 SHOWN. END BENT '2 SIMILAR. NOTES THE GUARDRAIL ANCHOR ASSEMBLY SHALL CONSIST OF A '/q" HOLD DOWN PLATE AND 7 - %8" 0 BOLTS WITH NUTS AND WASHERS. THE HOLD-DOWN PLATE SHALL CONFORM TO AASHTO M270 GRADE 36. AFTER FABRICATION, THE HOLD-DOWN PLATE SHALL BE HOTDIP GALVANIZED IN ACCORDANCE WITH AASHTO MI11. BOLTS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A307 AND NUTS SHALL CONFORM TO THE REQUIREMENTS OF AASHTO M291. BOLTS. NUTS AND WASHERS SHALL BE GALVANIZED. (AT THE CONTRACTOR'S OPTION.STAINL�SS STEEL BOLTS, NUTS AND WASHERS MAY BE USED AS AN ALTERNATE FOR THE /e" 0 GALVANIZED BOLTS. NUTS AND WASHERS. THEY SHALL CONFORM TO OR EXCEED THE MECHANICAL REQUIREMENTS OF ASTM A307. THE USE OF THIS ALTERNATE SHALL BE APPROVED BY THE ENGINEER.) THE GUARDRAIL ANCHOR ASSEMBLY IS REQUIRED AT ALL POINTS WHERE APPROACH GUARDRAIL IS TO BE ATTACHED TO THE END OF BARRIER RAIL. FOR POINTS OF ATTACHMENT.SEE SKETCH. AFTER INSTALLATION. THE EXPOSED THREAD OF THE BOLT SHALL BE BURRED WITH A SHARP POINTED TOOL. THE COST OF THE GUARDRAIL ANCHOR ASSEMBLY SHALL BE INCLUDED IN THE UNIT CONTRACT PRICE BID FOR VERTICAL CONCRETE BARRIER RAIL. THE VERTICAL REINFORCING BARS MAY BE SHIFTED SLIGHTLY IN THE VERTICAL CONCRETE BARRIER RAIL TO CLEAR ASSEMBLY BOLTS. THE 1'/4" 0 HOLES SHALL BE FORMED OR DRILLED WITH A CORE BIT. IMPACT TOOLS WILL NOT BE PERMITTED. ANY CONCRETE DAMAGED BY THIS WORK SHALL BE REPAIRED TO THE SATISFACTION OF THE ENGINEER. C JT. Q � JT. Q END BENT '1 END BENT '2 SKETCH SHOWING POINTS OF ATTACHMENT * DENOTES GUARDRAIL ANCHOR ASSEMBLY H1H CAR01 SEAL 1 C4ARlEs 4 PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- 4" 4" GUARDRAIL ANCHOR ASSEMBLY GUARDRAIL 4- ANCHOR ASSEMBLY PLAN LOCATION OF ANCHORS FOR GUARDRAIL END BENT '1 SHOWN. END BENT '2 SIMILAR. NOTES THE GUARDRAIL ANCHOR ASSEMBLY SHALL CONSIST OF A '/q" HOLD DOWN PLATE AND 7 - %8" 0 BOLTS WITH NUTS AND WASHERS. THE HOLD-DOWN PLATE SHALL CONFORM TO AASHTO M270 GRADE 36. AFTER FABRICATION, THE HOLD-DOWN PLATE SHALL BE HOTDIP GALVANIZED IN ACCORDANCE WITH AASHTO MI11. BOLTS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A307 AND NUTS SHALL CONFORM TO THE REQUIREMENTS OF AASHTO M291. BOLTS. NUTS AND WASHERS SHALL BE GALVANIZED. (AT THE CONTRACTOR'S OPTION.STAINL�SS STEEL BOLTS, NUTS AND WASHERS MAY BE USED AS AN ALTERNATE FOR THE /e" 0 GALVANIZED BOLTS. NUTS AND WASHERS. THEY SHALL CONFORM TO OR EXCEED THE MECHANICAL REQUIREMENTS OF ASTM A307. THE USE OF THIS ALTERNATE SHALL BE APPROVED BY THE ENGINEER.) THE GUARDRAIL ANCHOR ASSEMBLY IS REQUIRED AT ALL POINTS WHERE APPROACH GUARDRAIL IS TO BE ATTACHED TO THE END OF BARRIER RAIL. FOR POINTS OF ATTACHMENT.SEE SKETCH. AFTER INSTALLATION. THE EXPOSED THREAD OF THE BOLT SHALL BE BURRED WITH A SHARP POINTED TOOL. THE COST OF THE GUARDRAIL ANCHOR ASSEMBLY SHALL BE INCLUDED IN THE UNIT CONTRACT PRICE BID FOR VERTICAL CONCRETE BARRIER RAIL. THE VERTICAL REINFORCING BARS MAY BE SHIFTED SLIGHTLY IN THE VERTICAL CONCRETE BARRIER RAIL TO CLEAR ASSEMBLY BOLTS. THE 1'/4" 0 HOLES SHALL BE FORMED OR DRILLED WITH A CORE BIT. IMPACT TOOLS WILL NOT BE PERMITTED. ANY CONCRETE DAMAGED BY THIS WORK SHALL BE REPAIRED TO THE SATISFACTION OF THE ENGINEER. C JT. Q � JT. Q END BENT '1 END BENT '2 SKETCH SHOWING POINTS OF ATTACHMENT * DENOTES GUARDRAIL ANCHOR ASSEMBLY H1H CAR01 SEAL 1 C4ARlEs 4 PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- EL. 8.300 TOP OF SHEET PILES OUTSIDE OF CAP (LEVEL) POUR •2 UPPER PART L OF WINGS POUR •1 — CAP,LOWER & PART OF WINGS 39'-0' 1 T PILES 26 - PZ -27 GALVANIZED S 1'-10'/2" EL. 12.218 TOP OF WING (LEVEL) MIN TIP EL. -23.700 FOR SHEET PILES OUTSIDE OF CAP HP 12 X 53 GALVANIZED STEEL PILES PZ -27 STEEL SHEET PILES —� (TO RUN CONTINUOUS AS SHOWN IN PLAN VIEW) 191-6" I -L- LATERAL GUIDE SEE SHEET 4 OF 4 9�z" 9/2" FOR DETAILS (TYP. EA. END) 1'-7' I%2'EXP. JT. SEE DETAIL "A" (TYP.) (TYP.) MAT'L. (TYP.) (SHEET 4 OF 4) IL T PILES 19'-6" 1' 0" 1'-10'2- (TYPJ 1'X 8'X 2'-6' ELASTOMERIC BRG. 90°-00'-00" PAD (TYP.) POUR °3 LATERAL GUIDES — •4 B3 UNDER "4 82 OVER PILES Cd 4' -0 -CTS. (10 REO'D) PI AN EL. 9.718 (LEVEL) WORKLINE 5'MIN SPLICE (TYP.) 4-9 81 — 14 B4 Q 4'-0' CTS. (9 REO'D) 3-"482 (2 BAR RUNN I wz 1' 0" FOR WING DETAILS, SEE SHEET 3 OF 4. PZ -27 THE CONTRACTOR HAS THE OPTION TO OMIT THE LATERAL GUIDE IF APPROVED BY THE ENGINEER. ALL REINFORCING STEEL SHALL BE EPDXY COATED. ALL BAR SUPPORTS USED IN THE END BENT CAP SHALL BE EPDXY COATED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. CLASS AA CONCRETE SHALL BE USED IN THE 45° CONNECTOR END BENT CAPS AND SHALL CONTAIN CALCIUM i� 24 00'-00" 0 SEE DETAIL "A" Q AO'P� 21 SN��Z NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. THE LATERAL GUIDES ARE NOT TO BE POURED UNTIL AFTER THE CORED SLAB UNITS ARE IN PLACE. THE CONCRETE IN THE SHADED AREA OF THE WING SHALL BE POURED AFTER THE VERTICAL CONCRETE BARRIER RAIL IS CAST IF SLIP FORMING IS USED. FOR PILE SPLICE DETAILS,SEE SHEET 4 OF 4. PZ -27 EL. 12.218 - TOP OF WING {` (LEVEL) CONST. JT.� t7 (TYP.) N W z L 3-'4 B2 (OVER SHEET PILES) 6" (2 BAR RUNS) STEEL SHEET J = C� W W W J •4 62 (EACH FACE) 4-•4 B2 (OVER PILES) ti mo \ a W.P. v Na A (2 BAR RUNS) (2 BAR RUNS) cow FILL FACE MBEOMENT ^ W (TYP.) @ 5'-0" CTS. (TYP.) TURNED AND INSTALLED THROUGH �v) 1'-2%2" PILES THE SHEET PILES 8" 8-•4 51,52 & "4S5 8" 8" 16'-2/2" 16'-22" POUR °3 LATERAL GUIDES — •4 B3 UNDER "4 82 OVER PILES Cd 4' -0 -CTS. (10 REO'D) PI AN EL. 9.718 (LEVEL) WORKLINE 5'MIN SPLICE (TYP.) 4-9 81 — 14 B4 Q 4'-0' CTS. (9 REO'D) 3-"482 (2 BAR RUNN I wz 1' 0" FOR WING DETAILS, SEE SHEET 3 OF 4. PZ -27 THE CONTRACTOR HAS THE OPTION TO OMIT THE LATERAL GUIDE IF APPROVED BY THE ENGINEER. ALL REINFORCING STEEL SHALL BE EPDXY COATED. ALL BAR SUPPORTS USED IN THE END BENT CAP SHALL BE EPDXY COATED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. CLASS AA CONCRETE SHALL BE USED IN THE 45° CONNECTOR END BENT CAPS AND SHALL CONTAIN CALCIUM i� 24 00'-00" 0 SEE DETAIL "A" Q AO'P� 21 SN��Z NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. THE LATERAL GUIDES ARE NOT TO BE POURED UNTIL AFTER THE CORED SLAB UNITS ARE IN PLACE. THE CONCRETE IN THE SHADED AREA OF THE WING SHALL BE POURED AFTER THE VERTICAL CONCRETE BARRIER RAIL IS CAST IF SLIP FORMING IS USED. FOR PILE SPLICE DETAILS,SEE SHEET 4 OF 4. PZ -27 EL. 12.218 - TOP OF WING {` (LEVEL) CONST. JT.� t7 (TYP.) ELEVATION WINGS NOT SHOWN FOR CLARITY. FOR SECTION A -A. SEE SHEET 4 OF 4. 2- 4 S3 (TYP. EA. PILE) z L 3-'4 B2 (OVER SHEET PILES) 6" (2 BAR RUNS) STEEL SHEET INSTALLATION OF THE 4" DIAMETER •4 62 (EACH FACE) 4-•4 B2 (OVER PILES) PILE EMB. (TYP.) 1'-0"MIN. A (2 BAR RUNS) (2 BAR RUNS) 4'HIGH BEAM BOLSTER MBEOMENT THE DRAIN PIPE.ONCE THE PIPE IS @ 5'-0" CTS. (TYP.) TURNED AND INSTALLED THROUGH TOP OF SHEET PILES THE SHEET PILES 8" 8-•4 51,52 & "4S5 8" 8" (LEVEL) (TYP.) @ 8- TS. (TYP.) (TYP (TYP. EACH BAY) U- 6' 6'-0" MIN TIP EL. -18.000 FOR SHEET PILES — INSIDE OF CAP ELEVATION WINGS NOT SHOWN FOR CLARITY. FOR SECTION A -A. SEE SHEET 4 OF 4. NIS I EL. 7.218 I I I BOTTOM OF CAP & WING (LEVEL) I I 4 Sl, "4S2�5 (TYP. EACH END) MIN TIP EL. -23.700 FOR SHEET PILES OUTSIDE OF CAP CAkoj EAL 09 111E ? 'CVAP,LES PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 1 OF 4 NITRITE CORROSION INHIBITOR. THE CONTRACTOR SHALL PROVIDE FOR DETAIL " A INSTALLATION OF THE 4" DIAMETER DRAIN PIPE THROUGH THE WING WALL AS REQUIRED FOR REINFORCED BRIDGE APPROACH FILLS.SEE THE ROADWAY PLANS. REINFORCING STEEL IN THE WING WALL MAY BE SHIFTED AS NECESSARY TO CLEAR THE DRAIN PIPE.ONCE THE PIPE IS THROUGH THE WING THE PIPE SHALL BE EL. 8.300 TURNED AND INSTALLED THROUGH TOP OF SHEET PILES THE SHEET PILES n OUTSIQE OF CAP (LEVEL) NIS I EL. 7.218 I I I BOTTOM OF CAP & WING (LEVEL) I I 4 Sl, "4S2�5 (TYP. EACH END) MIN TIP EL. -23.700 FOR SHEET PILES OUTSIDE OF CAP CAkoj EAL 09 111E ? 'CVAP,LES PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 1 OF 4 1'� BENT CONTROL LINE & c PILES 17'-9' 17'- 9' 16'-71/2" NOTES / W.P. ---/// STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY - L- SHEET 2 OF 2. 9'z" / THE LATERAL GUIDES ARE NOT TO BE POURED UNTIL 2'-6"X 8'X 1" AFTER THE CORED SLAB UNITS ARE IN PLACE. ELASTOMERIC BEARING * INVERT ALTERNATE STIRRUPS. PAD (TYPE I) (TYP.) 1'-7' 1 -5` 901-00'-00" THE CONTRACTOR HAS THE OPTION TO OMIT THE (TYP.) (TYP.) LATERAL GUIDE IF APPROVED BY THE ENGINEER. 1ifz" ALL REINFORCING STEEL SHALL BE EPDXY COATED. PLAN ALL BAR SUPPORTS USED IN THE BENT CAP SHALL BE FOR LATERAL GUIDE= DETAILS, SEE NOTES / W.P. ---/// STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY 1/2"EXP. JT. MAT'L. (TYP.) SHEET 2 OF 2. THE LATERAL GUIDES ARE NOT TO BE POURED UNTIL AFTER THE CORED SLAB UNITS ARE IN PLACE. * INVERT ALTERNATE STIRRUPS. THE CONTRACTOR HAS THE OPTION TO OMIT THE SEE DETAIL "A" LATERAL GUIDE IF APPROVED BY THE ENGINEER. 1ifz" ALL REINFORCING STEEL SHALL BE EPDXY COATED. PLAN ALL BAR SUPPORTS USED IN THE BENT CAP SHALL BE •4 U1 SPECIFICATIONS. CLASS AA CONCRETE SHALL BE USED IN THE BENT CAPS (TYP. EA. END) AND SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. q CORED SPAN B B 4-•10 Bl WORKLINE (TYP.) LATERAL GUIDE02-MIN. (TYP.)ICE (TY PSE A °4 B5 Q 4'-O"CTS. (9 REQUIRED) CL D >- BEARING & DOWELS (TYP.) -- -�- n 9/2" 9/2" (TYP.) (TYP.) d SPAN A 3-•4 U2 Lo (TYP. EA. END) BENT CONTROL - LINE 4"HIGH B.B. 7 A i V2-'4 '9 U3 4 °4 B4 (OVER PILES) i (2 BAR RUNS) S2 (TYP. EA. PILE) ` '5 B3 (EACH FACE) 1'-0"MIN. EMBT DP Ej NT (TYP. EA. END) i i * "5 SI 1' 0" 9" * 6-"5 Sl 9" (TYP. EA. END) (TYP.) (TYP.) CJ 9" CTS. (TYP.) (TYP. EA. BAY) 5'-3" 5'-3" 5'-3" 5'-3" 5'-3" 5'-3" 2'-O" 16"PRESTRESSED CONCRETE PILES O O O O O © (D ELEVATION FOR SECTION A -A. SEE SHEET 2 OF 2 CONST. JT. (TYP.) 2'-6"X 8'X 1" *6 DI DOWELS TOP OF CAP ELASTOMERIC BEARING TO PROJECT 9' EL. 9.836 PAD (TYPE I) (TYP.) ABOVE CAP (TYP.) (LEVEL) DETAIL "A" (DIMENSIONS ARE TYPICAL EACH BEARING) �n z N � BOTTOMOF CAP EL. 7.336 (LEVEL) AL 09 czF 1 N �z �NAPViS- PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 1 OF 2 NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. THE LATERAL GUIDES ARE NOT TO BE POURED UNTIL AFTER THE CORED SLAB UNITS ARE IN PLACE. * INVERT ALTERNATE STIRRUPS. THE CONTRACTOR HAS THE OPTION TO OMIT THE LATERAL GUIDE IF APPROVED BY THE ENGINEER. 1ifz" ALL REINFORCING STEEL SHALL BE EPDXY COATED. ALL BAR SUPPORTS USED IN THE BENT CAP SHALL BE EPDXY COATED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. CLASS AA CONCRETE SHALL BE USED IN THE BENT CAPS AND SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. q CORED SPAN B B SLAB UNIT (TYP.) BEARING & DOWELS (TYP.) -- -�- n 9/2" 9/2" (TYP.) (TYP.) d SPAN A -R7 Lo BENT CONTROL - LINE CONST. JT. (TYP.) 2'-6"X 8'X 1" *6 DI DOWELS TOP OF CAP ELASTOMERIC BEARING TO PROJECT 9' EL. 9.836 PAD (TYPE I) (TYP.) ABOVE CAP (TYP.) (LEVEL) DETAIL "A" (DIMENSIONS ARE TYPICAL EACH BEARING) �n z N � BOTTOMOF CAP EL. 7.336 (LEVEL) AL 09 czF 1 N �z �NAPViS- PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 1 OF 2 PLAN "'I ELEVATION LATERAL GUIDE DETAILS (LEFT LATERAL GUIDE SHOWN, RIGHT SIDE SIMILAR) BENT CONTROL LINE DRAWN BY i M. U. IVT CHECKED BY : B. C. H DRAWN BY : DGE 05/10 CHECKED BY : MKT 05/10 DATE : 1/31/11 DATE : 2/2/11 SECTION h - A BAR NO. SIZE TYPE LENGTH WEIGHT Bi 4 °10 1 37'-8` 648 •4 B5 `a) 63 4 •5 STR 35'-2" 147 N. CL. I I( �Z N T — ---- i _ N U 5 --- D1 44 °6 STR 1' 6' 99 Q 1EXP. ° [- "4 U4 7'/2 •9 U3 (TIE TO '10 B2) 1'-0" 1'-0' JT. MAT'L. CONST. JT. PLAN "'I ELEVATION LATERAL GUIDE DETAILS (LEFT LATERAL GUIDE SHOWN, RIGHT SIDE SIMILAR) BENT CONTROL LINE DRAWN BY i M. U. IVT CHECKED BY : B. C. H DRAWN BY : DGE 05/10 CHECKED BY : MKT 05/10 DATE : 1/31/11 DATE : 2/2/11 SECTION A - A BAR NO. SIZE TYPE LENGTH WEIGHT Bi 4 °10 1 37'-8` 648 32 4 •10 STR 35-2" •4 U2 — BAR TYPES � �--1'-3., LAP HK. O HK. \�/y 1'-5" 34'-10" 1'-5" L2O Y 2'-B" U1 1'-11' U2 O 2'-7- U3 6' U4 r) 2'-9' °° O ALL BAR DIMENSIONS ARE OUT TO OUT. END OF CAP VIEW (TYPICAL BOTH ENDS) BILL OF MATERIAL FOR ONE BENT BAR NO. SIZE TYPE LENGTH WEIGHT Bi 4 °10 1 37'-8` 648 32 4 •10 STR 35-2" `a) 63 4 •5 STR 35'-2" 147 B4 8 •4 STR 18'-10' 101 85 13 '4 STR 2'-9" 24 D1 44 °6 STR 1' 6' 99 51 38 15 2 7'-7- 7'/2 •9 U3 (TIE TO '10 B2) 1'-0" 1'-0' 7'/2" END OF CAP VIEW (TYPICAL BOTH ENDS) BILL OF MATERIAL FOR ONE BENT BAR NO. SIZE TYPE LENGTH WEIGHT Bi 4 °10 1 37'-8` 648 32 4 •10 STR 35-2" 605 63 4 •5 STR 35'-2" 147 B4 8 •4 STR 18'-10' 101 85 13 '4 STR 2'-9" 24 D1 44 °6 STR 1' 6' 99 51 38 15 2 7'-7- 301 S2 14 '4 3 8'-1' 76 U1 4 °4 4 5'-8' 15 U2 6 •4 4 4'-11" 20 U3 2 °9 4 9'-11" 67 U4 8 °4 4 3'-6" 19 EPDXY COATED REINFORCING STEEL 2122 LBS (FOR ONE BENT) CLASS AA CONCRETE BREAKDOWN (FOR ONE BENT) POUR 'I (CAP) A 10.2 C.Y. POUR •2 (LATERAL GUIDES) 0.1 C.Y. TOTAL CLASS AA CONCRETE 10.3 C.Y. 16'PRESTRESSED CONCRETE PILES (FOR ONE BENT) No. 7 LIN. FT. 455 A CONCRETE DISPLACED BY THE 16"PRESTRESSED I CONCRETE PILES HAS BEEN DEDUCTED FROM THE CONCRETE QUANTITY. PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 2 OF 2 STATE OF MORTN CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH SUBSTRUCTURE BENT No.l REVISIONS 11 SHEET NO. DATES ND BY, I DATE: I S-14 131 LEES 18 BENT CONTROL LF INE C PILES FOR LATERAL GUIDE J DETAILS. SEE SHEET 2 OF 2. 17'-9' 17'-9" 16'-7/z" 16'-7/z" -L- "4 B5 (J 4'-0"CTS. (9 REOUIRED) 9'/2" F 2'-6" X 8'X 1' ELASTOMERIC BEARING PAD (TYPE I) (TYP.) V-7' 1-5" 90"-00'-00' (TYP.) (TYPJ rte— • •— — — 12 _LJ � — --�_ "L" (TYP. EA. ENDI — LATERAL GUTDF 3-"4 (TYP. EA. "9 U3 - (TYP. EA. Et W.P. SEE DETAIL "A" PLAN 4-110 B1 WORKLINE _2'-5"MIN. 0/2"EXP. JT. MAT'L. (TYP.) CONST. JT. (TYP.) TOP OF CAP EL. 9.956 (LEVEL) ELEVATION FOR SECTION A-A.SEE SHEET 2 OF 2 O O BOTTOMOF CAP EL. 7.456 (LEVEL) NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. THE LATERAL GUIDES ARE NOT TO BE POURED UNTIL AFTER THE CORED SLAB UNITS ARE IN PLACE. *INVERT ALTERNATE STIRRUPS. THE CONTRACTOR HAS THE OPTION TO OMIT THE LATERAL GUIDE IF APPROVED BY THE ENGINEER. ALL REINFORCING STEEL SHALL BE EPDXY COATED. ALL BAR SUPPORTS USED IN THE BENT CAP SHALL BE EPDXY COATED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. CLASS AA CONCRETE SHALL BE USED IN THE BENT CAPS AND SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. � CORED SLAB UNIT i 2'- 6' (TYP.) I BEARING ) 7' (TYP.) & DOWELS 9/2" 9/2" tTYPJ (TYP.) QIP % ----- c: cc ` - m r 10a BENT CONTROL - LINE 2'-6"X 8"X 1" 16 D1 DOWELS ELASTOMERIC BEARING TO PROJECT 9" PAD (TYPE I) (TYP.) ABOVE CAP (TYP.) DETAIL "A" (DIMENSIONS ARE TYPICAL EACH BEARING) � a S AL ` 1NE� per! CYARLVS�.+fi PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 —L— SHEET 1 OF 2 (TYP.) (T YA "4 B5 (J 4'-0"CTS. (9 REOUIRED) F 12 END) D i "4-*IOB2 N 4"HIGH B.B. IA (Z 5' -0 -CTS. I 4-"4 64 (OVERPILES)(TYP. i 12 BAR RUNS) 2-"4 S2 EA. PILE) "5 B31'-0"MIN. (EACH FACE) i EMBEDMENT D) I I I I I (TYP.) I 1'-0' 9" * 6-"5 Sl 9' (TYP. EA. END) (TYP.) (TYP.) (d 9" CTS. (TYP.) (TYP. EA. BAY) 2' 0" 5'-3" 5'-3" 5' 3" 5'-3" 5'-3" 5'-3" 2'-0" 16"PRESTRESSED CONCRETE PILES ELEVATION FOR SECTION A-A.SEE SHEET 2 OF 2 O O BOTTOMOF CAP EL. 7.456 (LEVEL) NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. THE LATERAL GUIDES ARE NOT TO BE POURED UNTIL AFTER THE CORED SLAB UNITS ARE IN PLACE. *INVERT ALTERNATE STIRRUPS. THE CONTRACTOR HAS THE OPTION TO OMIT THE LATERAL GUIDE IF APPROVED BY THE ENGINEER. ALL REINFORCING STEEL SHALL BE EPDXY COATED. ALL BAR SUPPORTS USED IN THE BENT CAP SHALL BE EPDXY COATED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. CLASS AA CONCRETE SHALL BE USED IN THE BENT CAPS AND SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. � CORED SLAB UNIT i 2'- 6' (TYP.) I BEARING ) 7' (TYP.) & DOWELS 9/2" 9/2" tTYPJ (TYP.) QIP % ----- c: cc ` - m r 10a BENT CONTROL - LINE 2'-6"X 8"X 1" 16 D1 DOWELS ELASTOMERIC BEARING TO PROJECT 9" PAD (TYPE I) (TYP.) ABOVE CAP (TYP.) DETAIL "A" (DIMENSIONS ARE TYPICAL EACH BEARING) � a S AL ` 1NE� per! CYARLVS�.+fi PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 —L— SHEET 1 OF 2 1112. 7 An -- •4 B5 Z. ,i v N LA U ( 648 B2 4 •10 STR 35'-2' v ~Z1�/p'EXP. B3 4 •5 STR 35'-2" '4 U4 A 101 B5 13 '4 STR 2'-9' JT. MAT'L. CONST. JT. PLAN "'j ELEVATION LATERAL GUIDE DETAILS (LEFT LATERAL GUIDE SHOWN,RIGHT SIDE SIMILAR) BENT CONTROL LINE 3'- 3' l'- 7'/2" V- 7'/2" 1'-2/," 10" V-2/," DRAWN BY : M. D. IVY DATE ; 1/31/11 CHECKED BY B. C. HUNT DATE : 2/2/11 DRAWN BY : DGE 01 /10 CHECKED BY 4KT OS/10 SECTION A -A '4 U2 — BAR TYPES � \ / 3•, LAP HK. O HK. 1'-5' 34'-10" 1'-5" O 2'-2" 0 Y x N 2'-8" UI 1'-11" U2 O 2'-7' U3 6" U4 r, 2'-9" °° ° O .n = ALL BAR DIMENSIONS ARE OUT TO OUT. F*4 U1 END OF CAP VIEW (TYPICAL BOTH ENDS) BILL OF MATERIAL FOR ONE BENT BAR NO. SIZE TYPE LENGTH WEIGHT B1 4 110 1 37'-8' 648 B2 4 •10 STR 35'-2' v+ B3 4 •5 STR 35'-2" 147 64 8 •4 STR 18'-10" 101 B5 13 '4 STR 2'-9' 24 D1 44 •6 STR 1'-6" 99 SI 3B •5 2 7'-7" 301 •9 U3 (TIE TO '10 62) 1 76 7'/2' END OF CAP VIEW (TYPICAL BOTH ENDS) BILL OF MATERIAL FOR ONE BENT BAR NO. SIZE TYPE LENGTH WEIGHT B1 4 110 1 37'-8' 648 B2 4 •10 STR 35'-2' 605 B3 4 •5 STR 35'-2" 147 64 8 •4 STR 18'-10" 101 B5 13 '4 STR 2'-9' 24 D1 44 •6 STR 1'-6" 99 SI 3B •5 2 7'-7" 301 S2 14 '4 3 8-1' 1 76 Ul 4 '4 4 5'-8" 15 U2 6 •4 1 4 4'-11" 20 U3 2 •9 4 9'-11" 67 U4 8 •4 4 3'-6" 19 EPDXY COATED REINFORCING STEEL (FOR ONE BENT) 2122 LBS CLASS AA CONCRETE BREAKDOWN (FOR ONE BENT) POUR •1 (CAP) ♦ 10.2 C.Y. POUR '2 (LATERAL GUIDES) 0.1 C.Y. TOTAL CLASS AA CONCRETE 10.3 C.Y. 16"PRESTRESSED CONCRETE PILES (FOR ONE BENT) No. 7 LIN. FT. 455 A CONCRETE DISPLACED BY THE 16"PRESTRESSED CONCRETE PILES HAS BEEN DEDUCTED FROM THE CONCRETE QUANTITY. PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 2 OF 2 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIL SUBSTRUCTURE BENT No.2 REVISIONS 11SHEET NO. Nol BT, 1 DATE. INOJ BY, I DATE, S-16 FI F\/ATT(1NI L w o H ' z W hJ-1 Q USF Z W !n O OHO N >L J O W w O W - "f , 16" m FOR ONE 16"PRESTRESSED PILE 5 TURN'S AT 1" PITCH LENGTH CONCRETE CU. YDS. w w J H TWO POINT PICK-UP 0.207L 0.586L 25'-0" 1.63 3.31 O W U LLO H J J H H d d uj � W 30'-0" c 3.97 91-0" W J CL 0 A x 2.29 4.63 10'-6" 24'-6" > O N ~ � z i U - 5.29 12'-0" 28'-0" O w a Q CC H 13'-6" 31'-6" 9'-4" 'J 50'-0" J H N 6.61 15'-0" 35'-0" 101-4" W a m B 7.28 � M 11'-4'/2" 32'-3- STRAND X OPTIONAL BUILD-UP WITH DOWELS 4.25 8.60 DOWELS 38'-1" H Q_ 9.26 14'-6" � 4.90 9.92 5 TURNS AT 1" PITCH BUILD-UP AND SPIRAL REINFORCING 16" i - I /- PRESTRESS STRAND (TYP,) -\ O O O O 2" CL. O TYP. O 1/z"0 FIELD DRILLED J HOLE (TYP.) W/ •8 DOWEL. SECTION "B -B" 2" CL. TYP. (AT THE CONTRACTOR'S OPTION, PILE BUILD-UP MAY BE CONSTRUCTED WITH DOWELS.) 16" 1" 8 PRESTRESS8-•6 BARS TYP.Fr STRANDS TYP. CL. TYP. 1 q D 22 2" CL. (3D4' TYP. 1 T W4.0 COLD DRAWN STEEL WIRE SPIRAL TYPICAL PATTERN TYPICAL SECTION SECTION "A -A" FOR BURNING STRANDS 1/2" OR 0.6" 0 GRADE 270 L.R. PRESTRESS STRANDS 16" 1" 8 PRESTRESS 8-6 BARS TYP. STRANDS 2" CL. TYP. 3 1 4 2" CL. n TYP. 2 2 4 1 LW4.0 COLD DRAWN STEEL WIRE SPIRAL-- TYPICAL PATTERN TYPICAL SECTION SECTION "A -A" FOR BURNING STRANDS 1/2" OR 0.6" 0 GRADE 270 L.R. PRESTRESS STRANDS PICK - UP POINTS QUANTITIES FOR ONE 16"PRESTRESSED PILE - LENGTH CONCRETE CU. YDS. w w J H TWO POINT PICK-UP 0.207L 0.586L 25'-0" 1.63 3.31 O W U LLO H J J H H d d uj � W 30'-0" 1.96 3.97 91-0" W J CL 0 Z L] ul Li 0 :2 O O 2.29 4.63 10'-6" 24'-6" > O N ~ > N H N Lu 5.29 12'-0" 28'-0" 8 3'/2' w a Q x w O CC � N W 13'-6" 31'-6" 9'-4" 26'-4' 50'-0" J H N 6.61 15'-0" 35'-0" 101-4" W a 55'-0" B 7.28 PRESTRESS B 11'-4'/2" 32'-3- STRAND 3.92 OPTIONAL BUILD-UP WITH DOWELS 16" i - I /- PRESTRESS STRAND (TYP,) -\ O O O O 2" CL. O TYP. O 1/z"0 FIELD DRILLED J HOLE (TYP.) W/ •8 DOWEL. SECTION "B -B" 2" CL. TYP. (AT THE CONTRACTOR'S OPTION, PILE BUILD-UP MAY BE CONSTRUCTED WITH DOWELS.) 16" 1" 8 PRESTRESS8-•6 BARS TYP.Fr STRANDS TYP. CL. TYP. 1 q D 22 2" CL. (3D4' TYP. 1 T W4.0 COLD DRAWN STEEL WIRE SPIRAL TYPICAL PATTERN TYPICAL SECTION SECTION "A -A" FOR BURNING STRANDS 1/2" OR 0.6" 0 GRADE 270 L.R. PRESTRESS STRANDS 16" 1" 8 PRESTRESS 8-6 BARS TYP. STRANDS 2" CL. TYP. 3 1 4 2" CL. n TYP. 2 2 4 1 LW4.0 COLD DRAWN STEEL WIRE SPIRAL-- TYPICAL PATTERN TYPICAL SECTION SECTION "A -A" FOR BURNING STRANDS 1/2" OR 0.6" 0 GRADE 270 L.R. PRESTRESS STRANDS PICK - UP POINTS QUANTITIES FOR ONE 16"PRESTRESSED PILE ULTIMATE LENGTH CONCRETE CU. YDS. PILE WT. TONS ONE POINT PICK-UP 0.30OL 0.70OL TWO POINT PICK-UP 0.207L 0.586L 25'-0" 1.63 3.31 7'-6" 17'-6' 5'-2" ]4-8' 30'-0" 1.96 3.97 91-0" 21'-0" 6'-2'/2" 17'-7" 35'-0" 2.29 4.63 10'-6" 24'-6" 7'-3" 20'-6" 40'-0" 2.61 5.29 12'-0" 28'-0" 8 3'/2' 23'-5" 45'-0" 2.94 5.95 13'-6" 31'-6" 9'-4" 26'-4' 50'-0" 3.27 6.61 15'-0" 35'-0" 101-4" 29'-4" 55'-0" 3.59 7.28 16'-6" 38'-6" 11'-4'/2" 32'-3- 601-01 3.92 7.94 12'-5" 35'-2' 4.25 8.60 13'-5'/2" 38'-1" 4.57 9.26 14'-6" 41'-0" 4.90 9.92 S5' 6'/z' 43'-11" 5.23 10.58 16'-7" 1 46-10" DOWEL INSTALLATION FOR OPTIONAL BUILD-UP NOTES PRESTRESSED CONCRETE STRENGTH :f'c= 7,500 PSI BUILD-UP CONCRETE STRENGTH :f'c= 7,500 PSI STRAND DATA: ALL PRESTRESSING STRANDS SHALL BE 7 -WIRE LOW -RELAXATION GRADE 270 STRANDS CONFORMING TO AASHTO M203. STRAND SAMPLING REQUIREMENTS SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. AT THE CONTRACTOR'S OPTION,'/2'OR 0.6 -STRANDS MAY BE USED IN EITHER STRAND CONFIGURATION SHOWN IN THE TYPICAL SECTION DETAIL.MIXING OF STRAND SIZE IS NOT ALLOWED. THE SLIP -FORM METHOD OF CASTING PILES WILL NOT BE PERMITTED. TRANSFER THE LOAD FROM THE ANCHORAGES TO THE PILE AFTER THE CONCRETE HAS ATTAINED A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI. IF STRAND STRESS IS RELIEVED BY BURNING, THE STRANDS SHALL BE BURNED IN OPPOSITE PAIRS AS INDICATED IN THE TYPICAL PATTERN SHOWN. FOR ANY NUMBER OF STRANDS.BURN IN OPPOSITE PAIRS AND SYMMETRICALLY ABOUT BOTH THE VERTICAL AND HORIZONTAL AXES. STRANDS 1-1 SHALL BE BURNED BEFORE 2-2. ETC. NOT MORE THAN 4 STRANDS, SAY 3-3 AND 4-4, MAY BE BURNED AT ANY ONE SECTION BEFORE THESE SAME PAIRS OF STRANDS ARE BURNED AT BOTH ENDS OF THE BED AND BETWEEN EACH PAIR OF PILES IN THE BED. PROPOSED DEVICES FOR LIFTING PILES, RECESS DETAILS, AND PATCHING MATERIAL SHALL BE DETAILED IN SHOP DRAWINGS. AFTER ATTACHMENTS HAVE BEEN REMOVED, OPENINGS SHALL BE REPAIRED SUCH THAT THE APPEARANCE OF THE PILE IS UNIFORM. WHERE CAST -IN-PLACE LIFTING DEVICES ARE NOT USED, PICK-UP POINTS ARE TO BE INDICATED WITH A 2" WIDE BLACK MARK. DRIVE PILES USING A METHOD APPROVED BY THE ENGINEER, WHEREBY THE HEAD OF THE PILE IS NOT DAMAGED. DRIVING OF THE BUILT-UP PILE WILL NOT BE PERMITTED UNTIL THE CONCRETE HAS REACHED A COMPRESSIVE STRENGTH OF 5.000 PSI AND UNTIL A PERIOD OF SEVEN DAYS HAS ELAPSED SINCE CASTING OF THE BUILD-UP. PRESTRESSED CONCRETE PILES SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. THE WATER/CEMENT RATIO FOR CONCRETE PILES SHALL NOT EXCEED 0.40. GROUT COMPRESSIVE STRENGTH:f'c= 5,000 PSI BEFORE DRILLING DOWEL HOLES,REMOVE THE UPPER 3"OF CONCRETE FROM THE TOP OF THE PILE WITHOUT DAMAGE TO THE REINFORCING STEEL.THE REMOVAL PLANE SHOULD BE NORMAL TO THE EDGE OF THE PILE. DOWEL HOLES SHALL BE POSITIONED TO MAINTAIN '/2 -CLEAR TO ALL EXISTING PRESTRESSING STRANDS IN THE CONCRETE PILE. FIELD DRILLED HOLES SHALL BE CLEAN AND FREE OF ANY OBSTRUCTIONS BEFORE GROUTING OF DOWELS. DOWEL BARS SHALL BE INSTALLED AND GROUTED WITH AN APPROVED NON -SHRINK GROUT. THE SPIRAL REINFORCING IN ALL BUILD-UPS SHALL BE W4.0 COLD DRAWN WIRE WHICH SHALL BE SECURED TO THE LONGITUDINAL REINFORCEMENT TO MAINTAIN PITCH. THE SPIRAL REINFORCING IN THE BUILD-UP AND THE PRESTRESSED CONCRETE PILE SHALL BE SPLICED BY OVERLAPPING A MIN.OF ONE TURN. ASN CAROL/ @aF S8)py y' 7 EAL CVAP.LE PROJECT NO. - BEAUFORT COUNTY STATION: 15+56.08 -L- B-5202 ULTIMATE APPLIED SIZE GRADE AREA STRENGTH PRESTRESS FORCE 270 L.R. 0.153 41.300• 30,980• PER STRAND PER STRAND 0.6" 270 L.R. 0.217 5B.600• 43.940• PER STRAND PER STRAND ALL PRESTRESSING STRANDS SHALL BE 7 -WIRE LOW -RELAXATION GRADE 270 STRANDS CONFORMING TO AASHTO M203. STRAND SAMPLING REQUIREMENTS SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. AT THE CONTRACTOR'S OPTION,'/2'OR 0.6 -STRANDS MAY BE USED IN EITHER STRAND CONFIGURATION SHOWN IN THE TYPICAL SECTION DETAIL.MIXING OF STRAND SIZE IS NOT ALLOWED. THE SLIP -FORM METHOD OF CASTING PILES WILL NOT BE PERMITTED. TRANSFER THE LOAD FROM THE ANCHORAGES TO THE PILE AFTER THE CONCRETE HAS ATTAINED A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI. IF STRAND STRESS IS RELIEVED BY BURNING, THE STRANDS SHALL BE BURNED IN OPPOSITE PAIRS AS INDICATED IN THE TYPICAL PATTERN SHOWN. FOR ANY NUMBER OF STRANDS.BURN IN OPPOSITE PAIRS AND SYMMETRICALLY ABOUT BOTH THE VERTICAL AND HORIZONTAL AXES. STRANDS 1-1 SHALL BE BURNED BEFORE 2-2. ETC. NOT MORE THAN 4 STRANDS, SAY 3-3 AND 4-4, MAY BE BURNED AT ANY ONE SECTION BEFORE THESE SAME PAIRS OF STRANDS ARE BURNED AT BOTH ENDS OF THE BED AND BETWEEN EACH PAIR OF PILES IN THE BED. PROPOSED DEVICES FOR LIFTING PILES, RECESS DETAILS, AND PATCHING MATERIAL SHALL BE DETAILED IN SHOP DRAWINGS. AFTER ATTACHMENTS HAVE BEEN REMOVED, OPENINGS SHALL BE REPAIRED SUCH THAT THE APPEARANCE OF THE PILE IS UNIFORM. WHERE CAST -IN-PLACE LIFTING DEVICES ARE NOT USED, PICK-UP POINTS ARE TO BE INDICATED WITH A 2" WIDE BLACK MARK. DRIVE PILES USING A METHOD APPROVED BY THE ENGINEER, WHEREBY THE HEAD OF THE PILE IS NOT DAMAGED. DRIVING OF THE BUILT-UP PILE WILL NOT BE PERMITTED UNTIL THE CONCRETE HAS REACHED A COMPRESSIVE STRENGTH OF 5.000 PSI AND UNTIL A PERIOD OF SEVEN DAYS HAS ELAPSED SINCE CASTING OF THE BUILD-UP. PRESTRESSED CONCRETE PILES SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. THE WATER/CEMENT RATIO FOR CONCRETE PILES SHALL NOT EXCEED 0.40. GROUT COMPRESSIVE STRENGTH:f'c= 5,000 PSI BEFORE DRILLING DOWEL HOLES,REMOVE THE UPPER 3"OF CONCRETE FROM THE TOP OF THE PILE WITHOUT DAMAGE TO THE REINFORCING STEEL.THE REMOVAL PLANE SHOULD BE NORMAL TO THE EDGE OF THE PILE. DOWEL HOLES SHALL BE POSITIONED TO MAINTAIN '/2 -CLEAR TO ALL EXISTING PRESTRESSING STRANDS IN THE CONCRETE PILE. FIELD DRILLED HOLES SHALL BE CLEAN AND FREE OF ANY OBSTRUCTIONS BEFORE GROUTING OF DOWELS. DOWEL BARS SHALL BE INSTALLED AND GROUTED WITH AN APPROVED NON -SHRINK GROUT. THE SPIRAL REINFORCING IN ALL BUILD-UPS SHALL BE W4.0 COLD DRAWN WIRE WHICH SHALL BE SECURED TO THE LONGITUDINAL REINFORCEMENT TO MAINTAIN PITCH. THE SPIRAL REINFORCING IN THE BUILD-UP AND THE PRESTRESSED CONCRETE PILE SHALL BE SPLICED BY OVERLAPPING A MIN.OF ONE TURN. ASN CAROL/ @aF S8)py y' 7 EAL CVAP.LE PROJECT NO. - BEAUFORT COUNTY STATION: 15+56.08 -L- B-5202 m � o U CI t R NOTES PAVEMENT N 6'BEVEL c ELBOW 4 •4 Al - BARS u L- •4 Al •5 BI z BARS 6 B2 ARS BARS t2 :l SLOPE FOR REINFORCED BRIDGE APPROACH FILL INCLUDING FABRIC, IMPERMEABLE CLASS "B'STONE TEMPORARY FOR EROSION CONTROL SLpPE --------- -------- DRAIN ll -•4A1 Q V-0"CTS. .n 1'-3' SEE ROADWAY PLANS. I I N (TOP OF SLAB) (2 BAR RUN) > AREA BETWEEN THE WINGWALL AND APPROACH SLAB SHALL BE GRADED TO 2'-09A I N. 1'' 0' ELBOW 11-•01 (Z 1'-0'CTS. _ - m a J In IN. FUTURE EARTH S1, f SHOULDER DITCH 4BOTTOM OF SLAB)(2 BAR RUN)' a N LL LL 0 BEGIN TOE OF FILL BLOCK 0 0 m APPROACH SLAB 6'COMP. A.B.C. V-0' a APPROACH SLAB AND SHALL EXTEND V-O'OUTSIDE OF EACH EDGE OF 'LEI i � 0 ¢ 0 0� t o APPROVED WIRE BAR ¢ N m \ ` SUPPORTS Q 3'-O'CTS. COURSE IN LIEU OF 6'COMP. A.B.C. IF THIS OPTION IS USED, THE BASE Q W J U F S2 COURSE SHALL BE FLUSH WITH THE ROADWAY END OF THE APPROACH SLAB. v AND THE WIDTH SHALL BE THE SAME AS THAT OF THE APPROACH SLAB. p @ D 3. 11-•4A1 Q 1'-O'CTS. 1'-3' m Q ITEM.SEE NOTES) p (TOP OF SLAB) (2 BAR RUN) m .n in WITH THE ROADWAY END OF THE APPROACH SLAB,AND THE WIDTH SHALL 9' 9- 11-•4A1 Q 1' -0 -CTS. FILL FACE Q 1'-3' m BE THE SAME AS THAT OF THE APPROACH SLAB. THE CONCRETE SHALL BE N � FLOW LINE I END BENT •1 FINISHED TO A SMOOTH SURFACE AND A LAYER OF 30 LB ROOFING FELT SHALL BE PLACED BETWEEN THE CONCRETE BASE AND THE APPROACH SLAB (BOTTOM OF SLAB)(2 BAR RUN) •4A1 END OF ® EROSION RESISTANT MATERIAL ___ --� APPROACH a u, TO PREVENT BOND. THE APPROACH SLAB SHALL NOT BE CAST UNTIL THE (BOTT. OF SLAB I'-6'MIN. LL CONCRETE BASE HAS REACHED AN AGE OF THREE CURING DAYS. SLAB) •78M STONE END 0 •4AI APPROACH SLAB o o FOR JOINT DETAILS,SEE "PRESTRESSED CONCRETE CORED SLAB UNIT' (TOP a o SHEETS. SLAB) DRAIN. CONTRACTOR SHALL GRADE TO PIPE INLET N ; FILL FACE Q r --END BENT 12 �•-� •4A1 (BOTT. OF SLAB) •4A1 (TOP OF 1 I SLAB) �N m u PLAN @ END BENT ttl PLAN na END BENT u2 DIMENSIONS SHOWN ARE TYPICAL FOR BOTH APPROACH SLABS BRIDGE DECK SO LAP FLOW LINE ONLY WITH EROSIOIIN RESISTANT MATERIAL ANDKGRADEETOADRAINN HOLE NOTE: IF THE APPROACH SLAB IS NOT CONSTRUCTED IMMEDIATELY AFTER THE BACKFILLING OF THE END BENT EXCAVATION, GRADE TO DRAIN TO THE BOTTOM OF THE SLOPE AND PROVIDE EROSION RESISTANT MATERIAL, SUCH AS FIBERGLASS ROVING OR AS DIRECTED BY THE ENGINEER TO PREVENT SOIL EROSION AND TO PROTECT THE AREA ADJACENT TO THE STRUCTURE. THE CONTRACTOR WILL BE REQUIRED TO REMOVE THESE MATERIALS PRIOR TO CONSTRUCTION OF THE APPROACH SLAB. TEMPORARY DRAINAGE DETAIL 8• 3'-1'/2" H.-----�{ � CURB N� APPROACH�Z SLAB SECTION N -N END OF CURB WITHOUT SHOULDER BERM GUTTER CURB DETAILS PROPOSED ASPHALT 51/4 -CONTINUOUS HIGH CHAIR UPPER ( CHCU ) Q 3' -0 -CTS. ACROSS SLAB t R NOTES PAVEMENT N # 6 c ELBOW 4 •4 Al - BARS u L- •4 Al •5 BI z BARS 6 B2 ARS BARS t2 :l SLOPE FOR REINFORCED BRIDGE APPROACH FILL INCLUDING FABRIC, IMPERMEABLE CLASS "B'STONE TEMPORARY FOR EROSION CONTROL SLpPE --------- -------- DRAIN GEOMEMBRANE. 4.0 DRAINAGE PIPE. •78M STONE, AND SELECT MATERIAL, R SEE ROADWAY PLANS. I I N > AREA BETWEEN THE WINGWALL AND APPROACH SLAB SHALL BE GRADED TO 2'-09A I N. 1'' 0' ELBOW _ - DRAIN THE WATER AWAY FROM THE FILL FACE OF THE BRIDGE AND SHALL CORED SLAB IN. FUTURE EARTH S1, f SHOULDER DITCH BE PAVED. SEE ROADWAY PLANS. TOE OF FILL BLOCK THE 6' COMP. A.B.C. SHALL BE FLUSH WITH THE ROADWAY END OF THE 6'COMP. A.B.C. V-0' APPROACH SLAB AND SHALL EXTEND V-O'OUTSIDE OF EACH EDGE OF 'LEI i � GROUT THE APPROACH SLAB. APPROVED WIRE BAR 6'BEVEL THE CONTRACTOR MAY USE 4'TYPE B-25.OB ASPHALT CONCRETE BASE \ ` SUPPORTS Q 3'-O'CTS. COURSE IN LIEU OF 6'COMP. A.B.C. IF THIS OPTION IS USED, THE BASE t2•_0. ROADWAY COURSE SHALL BE FLUSH WITH THE ROADWAY END OF THE APPROACH SLAB. LIMITS OF REINFORCED BRIDGE AND THE WIDTH SHALL BE THE SAME AS THAT OF THE APPROACH SLAB. 9' 9' 11-•4A1 Q 1'-O'CTS. 1'-3' THE CONTRACTOR MAY USE 5'CLASS "A" CONCRETE BASE IN LIEU OF 6' ITEM.SEE NOTES) COMP. A.B.C. IF THIS OPTION IS USED, THE CONCRETE BASE SHALL BE FLUSH (TOP OF SLAB) (2 BAR RUN) WITH THE ROADWAY END OF THE APPROACH SLAB,AND THE WIDTH SHALL 9' 9- 11-•4A1 Q 1' -0 -CTS. 1'-3' m BE THE SAME AS THAT OF THE APPROACH SLAB. THE CONCRETE SHALL BE N � FLOW LINE I m FINISHED TO A SMOOTH SURFACE AND A LAYER OF 30 LB ROOFING FELT SHALL BE PLACED BETWEEN THE CONCRETE BASE AND THE APPROACH SLAB (BOTTOM OF SLAB)(2 BAR RUN) � TYP. END OF ® EROSION RESISTANT MATERIAL ___ --� APPROACH a u, TO PREVENT BOND. THE APPROACH SLAB SHALL NOT BE CAST UNTIL THE SLAB I'-6'MIN. LL CONCRETE BASE HAS REACHED AN AGE OF THREE CURING DAYS. •78M STONE END 0 3' 3' APPROACH SLAB o o FOR JOINT DETAILS,SEE "PRESTRESSED CONCRETE CORED SLAB UNIT' — a o SHEETS. LmI DRAIN. CONTRACTOR SHALL GRADE TO PIPE INLET If U THE JOINT AT THE END BENT SHALL BE GROUTED AS SOON AS PRACTICAL AFTER THE CONSTRUCTION OF THE APPROACH SLABS. � PERFORATED PREVENT BOND AND PROVIDE EROSION RESISTANT MATERIAL AS SHOWN. THE 4' -O -MIN. ;0 0 APPROACH SLAB GROOVING IS NOT REQUIRED. EROSION RESISTANT MATERIAL SHALL BE EITHER 1)ASPHALT FILL SLOPE 3' Q ° Q FOR JOINT DETAILS.SEE "PRESTRESSED CONCRETE CORED SLAB UNIT" 90°-00'-00' 90°-00'-00' CArgO( SHEETS. (TYP.) (TYP.) THE SLOPE DRAIN SHALL CONSIST OF A NON -PERFORATED SECTION S -S 9, 2i N REINFORCED BRIDGE APPROACH FILLS. SEE THE ROADWAY PLANS. REINFORCING STEEL IN THE TEMPORARY DRAINAGE PIPE. 12 INCHES IN DIAMETER. THE JOINT AT THE END BENT SHALL BE GROUTED AS SOON AS PRACTICAL WING WALL MAY BE SHIFTED AS NECESSARY TO CLEAR �n AFTER THE CONSTRUCTION OF THE APPROACH SLABS. SEAL THE DRAIN PIPE. ONCE THE PIPE IS THROUGH THE WING APPROACH SLAB GROOVING IS NOT REQUIRED. R AA 91 M.D. IVY DATE s 9/20/10 THE PIPE SHALL BE TURNED AND INSTALLED THROUGH THE SHEET PILES1NE (TOP AND (TOP ND Ep B. C. HUNT DATE 9/20/10 BOT. OF SLAB) BOT, OF SLAB) I 1 J 'CbARIES?, AA 5-09 FILL FACE Q r --END BENT 12 �•-� •4A1 (BOTT. OF SLAB) •4A1 (TOP OF 1 I SLAB) �N m u PLAN @ END BENT ttl PLAN na END BENT u2 DIMENSIONS SHOWN ARE TYPICAL FOR BOTH APPROACH SLABS BRIDGE DECK SO LAP FLOW LINE ONLY WITH EROSIOIIN RESISTANT MATERIAL ANDKGRADEETOADRAINN HOLE NOTE: IF THE APPROACH SLAB IS NOT CONSTRUCTED IMMEDIATELY AFTER THE BACKFILLING OF THE END BENT EXCAVATION, GRADE TO DRAIN TO THE BOTTOM OF THE SLOPE AND PROVIDE EROSION RESISTANT MATERIAL, SUCH AS FIBERGLASS ROVING OR AS DIRECTED BY THE ENGINEER TO PREVENT SOIL EROSION AND TO PROTECT THE AREA ADJACENT TO THE STRUCTURE. THE CONTRACTOR WILL BE REQUIRED TO REMOVE THESE MATERIALS PRIOR TO CONSTRUCTION OF THE APPROACH SLAB. TEMPORARY DRAINAGE DETAIL 8• 3'-1'/2" H.-----�{ � CURB N� APPROACH�Z SLAB SECTION N -N END OF CURB WITHOUT SHOULDER BERM GUTTER CURB DETAILS PROPOSED ASPHALT 51/4 -CONTINUOUS HIGH CHAIR UPPER ( CHCU ) Q 3' -0 -CTS. ACROSS SLAB t R 2'-O" 1'-9„ PAVEMENT 2'-6" 2'-2- '-2""6 # 6 JOINT ELBOW 6. •4 Al - BARS u L- •4 Al •5 BI z BARS 6 B2 ARS BARS t2 :l SLOPE CLASS "B'STONE TEMPORARY FOR EROSION CONTROL SLpPE --------- -------- DRAIN R TEMP. SLOPE DRAIN q' -p• 2'-09A I N. 1'' 0' ELBOW _ - �_ _ CORED SLAB IN. FUTURE EARTH S1, f SHOULDER DITCH TOE OF FILL BLOCK 6'COMP. A.B.C. V-0' 'LEI � GROUT CLASS "B'STONE APPROACH FOR EROSION CONTROL APPROVED WIRE BAR �, \ ` SUPPORTS Q 3'-O'CTS. SLAB SECTION R -R ROADWAY _ LIMITS OF REINFORCED BRIDGE pFZpt iv -EROSION – APPROACH FILL (ROADWAY PAY 50 N E 3 RESISTANT ITEM.SEE NOTES) 'AN SPE 12'MIN. I MATERIAL OVER PIPE H j0 ? S� R� � � EARTH DZTCH BLOCK FABRIC p" N � FLOW LINE I T NORMAL TO END BENT � TYP. END OF ® EROSION RESISTANT MATERIAL ___ --� APPROACH SLAB I'-6'MIN. •78M STONE NOTE: IMMEDIATELY AFTER THE CONSTRUCTION OF THE APPROACH SLAB, 2 LAYERS OF 30 LB. THE CONTRACTOR SHALL PROVIDE TEMPORARY BERM AND SLOPE SELECT MATERIAL 4'0 CORRUGATED ROOFING FELT TO DRAIN. CONTRACTOR SHALL GRADE TO PIPE INLET PERFORATED PREVENT BOND AND PROVIDE EROSION RESISTANT MATERIAL AS SHOWN. THE 4' -O -MIN. DRAINAGE PIPE EROSION RESISTANT MATERIAL SHALL BE EITHER 1)ASPHALT FILL SLOPE THE CONTRACTOR SHALL PROVIDE FOR INSTALLATION OF IMPERMEABLE GEOMEMBRANE PLANT MIX, TYPE 1 OR TYPE 2, MIN. 2'DEPTH. 2) EROSION CONTROL MAT, OR 3)CONCRETE.AS DIRECTED BY THE ENGINEER. CArgO( THE 4'DIAMETER DRAIN PIPE THROUGH THE WING WALL AS REQUIRED FOR THE SLOPE DRAIN SHALL CONSIST OF A NON -PERFORATED SECTION S -S ��N REINFORCED BRIDGE APPROACH FILLS. SEE THE ROADWAY PLANS. REINFORCING STEEL IN THE TEMPORARY DRAINAGE PIPE. 12 INCHES IN DIAMETER. WING WALL MAY BE SHIFTED AS NECESSARY TO CLEAR SEAL THE DRAIN PIPE. ONCE THE PIPE IS THROUGH THE WING PLAN VIEW 91 M.D. IVY DATE s 9/20/10 THE PIPE SHALL BE TURNED AND INSTALLED THROUGH THE SHEET PILES1NE Ep B. C. HUNT DATE 9/20/10 TEMPORARY BERM AND SLOPE DRAIN DETAILS J 'CbARIES?, AA 5-09 EO SECTION THRU SLAB .«w.s/(s/ff 5-09 (TO BE USED WHEN SHOULDER BERM CUTTER IS REQUIRED) Vb-NAT-L()11 Otl.10 SPLICE LENGTHS BAR SIZE EPDXY COATED UNCOATED "4 2'-O" 1'-9„ °5 2'-6" 2'-2- '-2""6 # 6 3'-10' 2'-7" BRIDGE NO. 8-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- -L - EL. 12.575POUR °3 TOP OF WING LATERAL (LEVEL) GUIDES POUR •2 - UPPER PART OF WINGS POUR RI — CAP,LOWER & PART OF WINGS PZ -27 STEEL SHEET PILES (TO RUN CONTINUOUS AS SHOWN IN PLAN VIEW) C HP 12 X 53 GALVANIZED STEEL PILES ASSEMBLED BY : M. D. IVY DATE 1/26/11 CHECKED BY : B. C. HUNT DATE : 1/26/11 DRAWN BY s DGE 02/10 CHECKED BY T VKT 02/10 PLAN FA EL. 10.075 (LEVEL) WORKLINE - "4 B3 UNDER •4 B2 2-5- MIN OVER PILES (Z 4'-0"CTS. SPLICE (10 REO'Dl (TYP.) 4-19 BI - 14 B4 Cd 4'-0" CTS. (9 REO'D) 3-4B2 (2 BAR RUNN EL. 12.575 TOP OF WING CONST. JT. (LEVEL) a ~ T� 41 Ll L 3-•4 B2 2-4 S3 -/(OVER SHEET PILES) 6 (TYP. EA. PILE) Z4-°4 B2 (2 BAR RUNS) STEEL SHEET Z.4 B2 (EACH FACE) (OVER PILES) PILE EMB. (TYP.) i'-0"MIN, A (2 BAR RUNS) (2 BAR RUNS) 4'HIGH BEAM BOLSTER MBEDMENTFY 5'-0' CTS. (TYP.) \I B" B-°4 SI, S2 & '455"(TYP.) Cd B"CTS. P.) (TYP.) (TYP.EACH BAY) 61-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" ELEVATION WINGS NOT SHOWN FOR CLARITY. FOR SECTION A-A,SEE SHEET 4 OF 4. EL. 8.075 TOP OF SHEET PILES a (LEVEL) N � \-- EL. 7.575 1 1 1 BOTTOM OF CAP & WING (LEVEL) •4 S1 &�� (TYP, EACH END) �optN CU001 y9 EAL 09 Gc CINf,� J2� 'CVA RLES� It PZ -27 I 45' CONNECTOR DETAIL "A" Z-27 t NOTES STIRRUPS IN CAP MAY BE SHIFTED AS NECESSARY TO CLEAR DOWELS. THE LATERAL GUIDES ARE NOT TO BE POURED UNTIL AFTER THE CORED SLAB UNITS ARE IN PLACE. THE CONCRETE IN THE SHADED AREA OF THE WING SHALL BE POURED AFTER THE VERTICAL CONCRETE BARRIER RAIL IS CAST IF SLIP FORMING IS USED. FOR PILE SPLICE DETAILS,SEE SHEET 40F 4. FOR WING DETAILS, SEE SHEET 3 OF 4. THE CONTRACTOR HAS THE OPTION TO OMIT THE LATERAL GUIDE IF APPROVED BY THE ENGINEER. ALL REINFORCING STEEL SHALL BE EPDXY COATED. ALL BAR SUPPORTS USED IN THE END BENT CAP SHALL BE EPDXY COATED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS. CLASS AA CONCRETE SHALL BE USED IN THE END BENT CAPS AND SHALL CONTAIN CALCIUM NITRITE CORROSION INHIBITOR. THE CONTRACTOR SHALL PROVIDE FOR INSTALLATION OF THE 4"DIAMETER DRAIN PIPE THROUGH THE WING WALL AS REQUIRED FOR REINFORCED BRIDGE APPROACH FILLS,SEE THE ROADWAY PLANS. REINFORCING STEEL IN THE WING WALL MAY BE SHIFTED AS NECESSARY TO CLEAR THE DRAIN PIPE.ONCE THE PIPE IS THROUGH THE WING THE PIPE SHALL BE TURNED AND INSTALLED THROUGH THE SHEET PILES PROJECT No. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHFFT 2 OF 4 STATE OF RORTH OAROLIHA DEPARTMENT OF TRANSPORTATION RALEIGH SUBSTRUCTURE END BENT No.2 REVISIONS SHEET NO. DATE, N Br,131 DATE. S-10 TOTAL 141 SHEETS 18 4'-0" 4'-0" 3'-0" 7'-6" 10'-6" PLAN OF WING Wl °4 KI (EA. FACE) __l BOTTOM OF (LEVEL) X 4 °4 VI BARS (EA. FACE) 3" (SPACED AS SHOWN ABOVE) TOP OF WING (LEVEL) CONST. JT. .. ........................................................ 4"HIGH B.B. G) 5'-0"CTS. XAJ ELEVATION OF WING W1 7'-6" 3'-0" 10'-6" PLAN OF WING W2 F+Y .G vi RAG, rCA CArCI (SPACED AS SHOWN ABOVE) TOP OF WING (LEL) " v+ (EA. FACE) WING DETAILS L+ (LEVEL) Y ELEVATION OF WING W2 j:CL. � 3" CL. — 4"HIGH B.B. SECTION X- 11-0* 3" CL. � 3" CL. n a Q ' FILL "4 V1 w N U FACE U N a U w x a N o CONST. JT. N 4"HIGH B.B. —� SECTION Y -Y C, O o a d PROJECT NO. B-5202 BEAUFORT COUNTY tr STATION: 15+56.08 -L- SHEET 3 OF 4 �pSN CAR01,y1 SEAL ` 91 G !NE or CYARLES�.F S G gf a r I •4 VI w U N Ln v e U W FILL FACE x v 0 ( N F- . N o CONST. JT. — 4"HIGH B.B. SECTION X- 11-0* 3" CL. � 3" CL. n a Q ' FILL "4 V1 w N U FACE U N a U w x a N o CONST. JT. N 4"HIGH B.B. —� SECTION Y -Y C, O o a d PROJECT NO. B-5202 BEAUFORT COUNTY tr STATION: 15+56.08 -L- SHEET 3 OF 4 �pSN CAR01,y1 SEAL ` 91 G !NE or CYARLES�.F S G gf MINIMUM OF 3- ONE CUBIC FOOT BAGS OF *78M STONE. BAGS SHALL BE OF POROUS FABRIC,SECURELY TIED. M)INAGE M 7 / ;; ( i� 1 FFORDRA) PIPE FORDRAINAGE DRAINAGE GRADE TO DRAIN GRADE TO DRAIN TOE OF SLOPE TOE OF SLOP BAGGED STONE AND PIPE SHALL BE PLACED IMMEDIATELY AFTER COMPLETION OF END BENT EXCAVATION. PIPE MAY BE EITHER CONCRETE, CORRUGATED STEEL, CORRUGATED ALUMINUM ALLOY, OR CORRUGATED PLASTIC. PERFORATED PIPE WILL NOT BE ALLOWED. BAGGED STONE SHALL REMAIN IN PLACE UNTIL THE ENGINEER DIRECTS THAT IT BE REMOVED. THE CONTRACTOR SHALL REMOVE AND DISPOSE OF SILT ACCUMULATIONS AT BAGGED STONE WHEN SO DIRECTED BY THE ENGINEER. BAGS SHALL BE REMOVED AND REPLACED WHENEVER THE ENGINEER DETER- MINES THAT THEY HAVE DETERIORATED AND LOST THEIR EFFECTIVENESS. NO SEPARATE PAYMENT WILL BE MADE FOR THIS WORK AND THE ENTIRE COST OF THIS WORK SHALL BE INCLUDED IN THE UNIT CONTRACT PRICE BID FOR THE SEVERAL PAY ITEMS. TEMPORARY DRAINAGE AT END BENT BACK GOUGE CORED 7 -<DETAIL A �SLAB UNIT 45° 2'-6" * PILE VERTICAL m PILE HORIZONTAL � BEARING 1'-3' 1 1'-3" /T - *6 D1 DOWELS TO PROJECT o 9"ABOVE CAP (TYP.) 7 4, a� m I � c I 1"X 8-X 2'-6' 9'/2' 91/2" ELASTOMERIC BRG. I'-7" PAD (TYPJ FILL FACE DETAIL "A" (END BENT No.1 SHOWN, END BENT No.2 SIMILAR BY ROTATION) � -1—'-0"-1 I , 11/z„ E'. JT. MA S4 OR VERTICAL +10. � 60°-0 ° 0 0 0,. TO 1/B" DETAIL A o a POSITION OF PILE DURING WELDING. DETAIL B PILE SPLICE DETAILS PLAN ELEVATION LATERAL GUIDE DETAILS (RIGHT LATERAL GUIDE SHOWN, LEFT END SIMILAR) ASSEMBLED BY , M. D. IVY DATE 1/26/11 CHECKED BY : B. C. HUNT DATE : 1/26/11 DRAWN BY : DGE 02/10 CHECKED BY : MKT 02/10 06-UAY-2011 08.79 Z f CK GOUGE TAIL B FILL ------ L FACE 4 -*9 Bl *4 82 (EA. FACE) °4 B3 *4 SI - *4 82 (EA. FACE) 4-19 B1 3" CL. (TYP.) 4" HIGH B.B. •4B4 HK. O HK, 1'-3" 38'-6' 1'-3" 4 /2' 2-3' 3' HK. HK. 4 — BAR TYPES — m� O 7'-0' LAP O ALL BAR DIMENSIONS ARE OUT TO OUT. O o N END BENT No.l END BENT No.2 HP 12 X 53 HP 12 X 53 GALVANIZED STEEL PILES GALVANIZED STEEL PILES N0: 7 LIN. FT.= 455 NO: 7 LIN. FT.= 420 18"GALVANIZED STEEL SHEET PILES 18 -GALVANIZED STEEL SHEET PILES N0. PZ -27 74 N0. PZ -27 46 NO.45° CONN. 1 NO.45° CONN. 2 TOTAL NO. 75 SO. FT. 3307 TOTAL NO. 48 SO. FT. 1386 1'-0" 11" FOR ONE END BENT BAR NO. SIZE TYPE LENGTH 10" BI 8 *9 1 41'-0' V- 71/2 B2 28 *4 STR 20'-6' 383 B3 10 *4 STR 2'-4' 16 =6 21 4 -*4 62 Q 4" CTS. DOWELQ H1 24 •4 2 7'-8' OVER PILES =4 S2 K1 12 •4 STR 2'-9' 22 3 -*4 62 S1 50 •4 3 6'-11" 231 S2 50 *4 4 3'-0" 14 S5 3 -*4 B2 (J 4" CTS. S3 14 •4 5 6'-6' 61 3' OVER SHEET PILES 15 SR 50 •4 7 5' 6" CLR. ----- — OT '4 S3 fl z 2465 LBS. CLASS AA CONCRETE BREAKDOWN (FOR ONE END BENT) POUR *1 CAP, LOWER PART OF WINGS & COLLARS POUR *2 UPPER PART OF WINGS POUR '3 LATERAL GUIDES TOTAL CLASS AA CONCRETE 15.7 C.Y. 1.8 C.Y. 0.1 C.Y. 17.6 C.Y. N H � 8"- 1 1'-5' 2" HIGH B.B. HP 12 X 53 PZ -27 GALVANIZDED GALVANIZED STEEL PILE 1 � STEEL SHEET PILES V-41112 ��atH CARol,,�i SEAL 09 SECTION A -A c+raRLE� BILL OF MATERIAL FOR ONE END BENT BAR NO. SIZE TYPE LENGTH WEIGHT BI 8 *9 1 41'-0' 1115 B2 28 *4 STR 20'-6' 383 B3 10 *4 STR 2'-4' 16 B4 9 •4 STR 3'-6' 21 Di 22 *6 1 STR 1'-6' 50 H1 24 •4 2 7'-8' 123 K1 12 •4 STR 2'-9' 22 S1 50 •4 3 6'-11" 231 S2 50 *4 4 3'-0" 100 S3 14 •4 5 6'-6' 61 S4 4 •4 6 5'-8' 15 SR 50 •4 7 5' 6" 184 VI 48 •4 STR 476- 144 EPDXY COATED REINFORCING STEEL (FOR ONE END BENT) 2465 LBS. CLASS AA CONCRETE BREAKDOWN (FOR ONE END BENT) POUR *1 CAP, LOWER PART OF WINGS & COLLARS POUR *2 UPPER PART OF WINGS POUR '3 LATERAL GUIDES TOTAL CLASS AA CONCRETE 15.7 C.Y. 1.8 C.Y. 0.1 C.Y. 17.6 C.Y. PROJECT NO. B-5202 BEAUFORT COUNTY STATION: 15+56.08 -L- SHEET 4 OF 4 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH SUBSTRUCTURE END BENT DETAILS REVISIONS SHEET NO. ND Br, I PATE: BY$ I DATE, S-12 SE5 DESIGN DATA: SPECIFICATIONS - - - - - - - - - - - - - - - A.A.S.H.T.O. (CURRENT) LIVE LOAD --- ----- --- - - - --- SEE PLANS IMPACT ALLOWANCE - - - - - - - - - - - - - - SEE A.A.S.H.T.O. STRESS IN EXTREME FIBER OF STRUCTURAL STEEL - AASHTO M270 GRADE 36 - 20,000 LBS. PER SO. IN. - AASHTO M270 GRADE 50W - 27,000 LBS. PER SO. IN. - AASHTO M270 GRADE 50 - 27,000 LBS. PER SO. IN. REINFORCING STEEL IN TENSION GRADE 60 - - 24.000 LBS. PER SO. IN. CONCRETE IN COMPRESSION - - - - - - - - - - 1,200 LBS. PER SO. IN. CONCRETE IN SHEAR - - - - - - - - - - - - - SEE A.A.S.H.T.O. STRUCTURAL TIMBER - TREATED OR UNTREATED - EXTREME FIBER STRESS - - - - - 1.800 LBS. PER SO. IN. COMPRESSION PERPENDICULAR TO GRAIN OF TIMBER - - - - 375 LBS. PER SO. IN. EQUIVALENT FLUID PRESSURE OF EARTH - -- - - 30 LBS. PER CU. FT. (MINIMUM) MATERIAL AND WORKMANSHIP: EXCEPT AS MAY OTHERWISE BE SPECIFIED ON PLANS OR IN THE SPECIAL PROVISIONS, ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE 2006 "STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES"OF THE N.C.DEPARTMENT OF TRANSPORTATION. STEEL SHEET PILING FOR PERMANENT OR TEMPORARY APPLICATIONS SHALL BE HOT ROLLED. CONCRETE: UNLESS OTHERWISE REQUIRED ON PLANS. CLASS A CONCRETE SHALL BE USED FOR ALL PORTIONS OF ALL STRUCTURES WITH THE EXCEPTION THAT: CLASS AA CONCRETE SHALL BE USED IN BRIDGE SUPERSTRUCTURES, ABUTMENT BACKWALLS,AND APPROACH SLABS; AND CLASS B CONCRETE SHALL BE USED FOR SLOPE PROTECTION AND RIP RAP. CONCRETE CHAMFERS: UNLESS OTHERWISE NOTED ON THE PLANS. ALL EXPOSED CORNERS ON STRUCTURES SHALL BE CHAMFERED 3/4"WITH THE FOLLOWING EXCEPTIONS: TOP CORNERS OF CURBS MAY BE ROUNDED TO 1-1/2"RADIUS WHICH IS BUILT INTO CURB FORMS; CORNERS OF TRANSVERSE FLOOR EXPANSION JOINTS SHALL BE ROUNDED WITH A 1/4"FINISHING TOOL UNLESS OTHERWISE REQUIRED ON PLANS;AND CORNERS OF EXPANSION JOINTS IN THE ROADWAY FACES AND TOPS OF CURBS AND SIDEWALKS SHALL BE ROUNDED TO A 1/4"RADIUS WITH A FINISHING STONE OR TOOL UNLESS OTHERWISE REQUIRED ON PLANS. DOWELS: DOWELS WHEN INDICATED ON PLANS AS FOR CULVERT EXTENSIONS. SHALL BE EMBEDDED AT LEAST 12"INTO THE OLD CONCRETE AND GROUTED INTO PLACE WITH 1:2 CEMENT MORTAR. STANDARD NOTES ALLOWANCE FOR DEAD LOAD DEFLECTION,SETTLEMENT, ETC.IN CASTING SUPERSTRUCTURES: BRIDGES SHALL BE BUILT ON THE GRADE OR VERTICAL CURVE SHOWN ON PLANS. SLABS, CURBS AND PARAPETS SHALL CONFORM TO THE GRADE OR CURVE. ALL DIMENSIONS WHICH ARE GIVEN IN SECTION AND ARE AFFECTED BY DEAD LOAD DEFLECTIONS ARE DIMENSIONS AT CENTER LINE OF BEARING UNLESS OTHERWISE NOTED ON PLANS. IN SETTING FORMS FOR STEEL BEAM BRIDGES AND PRESTRESSED CONCRETE GIRDER BRIDGES. ADJUSTMENTS SHALL BE MADE DUE TO THE DEAD LOAD DEFLECTIONS FOR THE ELEVATIONS SHOWN. WHERE BLOCKS ARE SHOWN OVER BEAMS FOR BUILDING UP TO THE SLAB. THE VERTICAL DIMENSIONS OF THE BLOCKS SHALL BE ADJUSTED BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTIONS, VERTICAL CURVE ORDINATE. AND ACTUAL BEAM CAMBER. WHERE BOTTOM OF SLAB IS IN LINE WITH BOTTOM OF TOP FLANGES, DEPTH OF SLAB BETWEEN BEARINGS SHALL BE ADJUSTED TO COMPENSATE FOR DEAD LOAD DEFLECTION, VERTICAL CURVE ORDINATE, AND ACTUAL BEAM CAMBER. IN SETTING FALSEWORK AND FORMS FOR REINFORCED CONCRETE SPANS, AN ALLOWANCE SHALL BE MADE FOR DEAD LOAD DEFLECTIONS, SETTLEMENT OF FALSEWORK, AND PERMANENT CAMBER WHICH SHALL BE PROVIDED FOR IN ADDITION TO THE ELEVATIONS SHOWN. AFTER REMOVAL OF THE FALSEWORK, THE FINISHED STRUCTURES SHALL CONFORM TO THE PROFILE AND ELEVATIONS SHOWN ON THE PLANS AND CONSTRUCTION ELEVATIONS FURNISHED BY THE ENGINEER. DETAILED DRAWINGS FOR FALSEWORK OR FORMS FOR BRIDGE SUPERSTRUCTURE AND ANY STRUCTURE OR PARTS OF A STRUCTURE AS NOTED ON THE PLANS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL BEFORE CONSTRUCTION OF THE FALSEWORK OR FORMS IS STARTED. REINFORCING STEEL: ALL REINFORCING STEEL SHALL BE DEFORMED. DIMENSIONS RELATIVE TO PLACEMENT OF REINFORCING ARE TO CENTERS OF BARS UNLESS OTHERWISE INDICATED IN THE PLANS. DIMENSIONS ON BAR DETAILS ARE TO CENTERS OF BARS OR ARE OUT TO OUT AS INDICATED ON PLANS. WIRE BAR SUPPORTS SHALL BE PROVIDED FOR REINFORCING STEEL WHERE INDICATED ON THE PLANS. WHEN BAR SUPPORT PIECES ARE PLACED IN CONTINUOUS LINES, THEY SHALL BE SO PLACED THAT THE ENDS OF THE SUPPORTING WIRES SHALL BE LAPPED TO LOCK LEGS ON ADJOINING PIECES. STRUCTURAL STEEL: AT THE CONTRACTOR'S OPTION, HE MAY SUBSTITUTE 7/8"0 SHEAR STUDS FOR THE Y4"0 STUDS SPECIFIED ON THE PLANS. THIS SUBSTITUTION SHALL BE MADE AT THE RATE OF 3 - 7/8"0 STUDS FOR 4 - 3/4"0 STUDS, AND STUD SPACING CHANGES SHALL BE MADE AS NECESSARY TO PROVIDE THE SAME EQUIVALENT NUMBER OF 7/8"0 STUDS ALONG THE BEAM AS SHOWN FOR 3/4"0 STUDS BASED ON THE RATIO OF 3 - 7/8'0 STUDS FOR 4 - 3/4"0 STUDS. STUDS OF THE LENGTH SPECIFIED ON THE PLANS MUST BE PROVIDED. THE MAXIMUM SPACING SHALL BE 2'-O". EXCEPT AT THE INTERIOR SUPPORTS OF CONTINUOUS BEAMS WHERE THE COVER PLATE IS IN CONTACT WITH BEARING PLATE. THE CONTRACTOR MAY, AT HIS OPTION, SUBSTITUTE FOR THE COVER PLATES DESIGNATED ON THE PLANS COVER PLATES OF THE EQUIVALENT AREA PROVIDED THESE PLATES ARE AT LEAST 5/16"IN THICKNESS AND DO NOT EXCEED A WIDTH EQUAL TO THE FLANGE WIDTH LESS 2"OR A THICKNESS EQUAL TO 2 TIMES THE FLANGE THICKNESS. THE SIZE OF FILLET WELDS SHALL CONFORM TO THE REQUIREMENTS OF THE CURRENT ANSI/AASHTO/AWS "BRIDGE WELDING CODE". ELECTROSLAG WELDING WILL NOT BE PERMITTED. WITH THE SOLE EXCEPTION OF EDGES AT SURFACES WHICH BEAR ON OTHER SURFACES.ALL SHARP EDGES AND ENDS OF SHAPES AND PLATES SHALL BE SLIGHTLY ROUNDED BY SUITABLE MEANS TO A RADIUS OF APPROXIMATELY 1/16 INCH OR EQUIVALENT FLAT SURFACE AT A SUITABLE ANGLE PRIOR TO PAINTING, GALVANIZING. OR METALLIZING. HANDRAILS AND POSTS: METAL STANDARDS AND FACES OF THE CONCRETE END POSTS FOR THE METAL RAIL SHALL BE SET NORMAL TO THE GRADE OF THE CURB, UNLESS OTHERWISE SHOWN ON PLANS. THE METAL RAIL AND TOPS OF CONCRETE POSTS USED WITH THE ALUMINUM RAIL SHALL BE BUILT PARALLEL TO THE GRADE OF THE CURB. METAL HANDRAILS SHALL BE IN ACCORDANCE WITH THE PLANS. RAILS SHALL BE AS MANUFACTURED FOR BRIDGE RAILING. CASTINGS SHALL BE OF A UNIFORM APPEARANCE. FINS AND OTHER DEFORMATIONS RESULTING FROM CASTING OR OTHERWISE SHALL BE REMOVED IN A MANNER SO THAT A UNIFORM COLORING OF THE COMPLETED CASTING SHALL BE OBTAINED. CASTINGS WITH DISCOLORATIONS OR OF NON-UNIFORM COLORING WILL NOT BE ACCEPTED.CERTIFIED MILL REPORTS ARE REQUIRED FOR METAL RAILS AND POSTS. SPECIAL NOTES: GENERALLY, IN CASE OF DISCREPANCY, THIS STANDARD SHEET OF NOTES SHALL GOVERN OVER THE SPECIFICATIONS, BUT THE REMAINDER OF THE PLANS SHALL GOVERN OVER NOTES HEREON, AND SPECIAL PROVISIONS SHALL GOVERN OVER ALL. SEE SPECIFICATIONS ARTICLE 105-4. 1