Loading...
HomeMy WebLinkAbout43652_MURRAY, GEORGIA_20051215C-' CAMA / L-; DREDGE &FILL GENERAL PERMIT 1 Previous permit # , ❑New JModification -Complete Reissue ❑Partial Reissue Date previous permit issued As authorized by the State of North Carolina, Department of Environment and Natural Re ources and the Coastal Resources Commission in an area of environmental concern pursrant to 15A NCAC f Applicant Name �. ` ' , r' �`' ` ` i� i Project Location: (] Rules attached. County Address_ , _ J =-X / % Street Address/ State Road/ Lot #(s) City_ �i���ra i �/ ! l Stater". ZIP Phone # (__) ; Fax # (} Subdivision Authorized Agent City Z ; '" ` ; ,^ / / -' Affected I_ I CW =: EW ❑ PTA JIBS ❑ PTS Phone # (,) _ River Basin I -; OEA ❑ HHF ❑ 1H ❑ UBA ❑ N/A AEC(s): Adj. Wtr. Body ' (nat /man /unkn) ❑ PWS: ❑FC: - ORW: yes / no PNA yes / no Crit. Hab. yes / no Closest Maj. Wtr. Body Type of Project/ Activity Pier (dock) length Platform(s) _ Finger pier(s) Groin length number Bulkhead/ Riprap length avg distance offshore max distance offshore Basin, channel cubic yards__ Boat ramp Boathouse/ Boatlift Beach Bulldozing Other Shoreline Length i SAM not sure yes Ao _ Sandbags: not sure yes nq Moratorium: n/a yes no Photos: yes no Waiver Attached: yes no A building permit may be required by: Notes/ Special Conditions Agent9l'Applicant Printed Name , Signature Please read compliance statement on back of permit" Application Fee(s) Check # (Scale: _ See note on back regarding River Basin rules. Permit Officer's Signature Issuing Expiration'Date Local Planning Jurisdiction Rover File Name r • Statement of Compliance and Consistency This permit is subject to compliance with this application, site drawing and attached general and specific conditions. Any violation of these terms may subject the permittee to a fine or criminal or civil action; and may cause the permit to become null and void. This permit must be on the project site and accessible to the permit officer when the project is inspected for compliance. The applicant certifies by signing this permit that 1) prior to undertaking any activities authorized by this permit, the applicant will confer with appropriate local authorities to confirm that this project is consistent with the local land use plan and all local ordinances, and 2) a written statement or certified mail return receipt has been obtained from the adjacent riparian landowner(s) . The State of North Carolina and the Division of Coastal Management, in issuing this permit under the best available information and belief, certify that this project is consistent with the North Carolina Coastal Management Program. River Basin Rules Applicable To Your Project: 0 Tar - Pamlico River Basin Buffer Rules ❑ Other: E] Neuse River Basin Buffer Rules If indicated on front of permit, your project is subject to the Environmental Management Commission's Buffer Rules for the River Basin checked above due to its location within that River Basin. These buffer rules are enforced by the NC Division of Water Quality. Contact the Division of Water Quality at the Washington Regional Office (252-946-6481) or the Wilmington Regional Office (910-796-7215) for more information on how to comply with these buffer rules. Division of Coastal Management Offices Central Office Mailing Address: 1638 Mail Service Center Raleigh, NC 27699-1638 Location: Parker -Lincoln Building 2728 Capital Blvd. Raleigh, NC 27604 919-733-2293 Fax: 919-733-1495 Elizabeth City District 1367 U.S. 17 South Elizabeth City, NC 27909 252-264-3901 Fax: 252-264-3723 (Serves: Camden, Chowan, Currituck, Dare, Gates, Pasquotank and Perquimans Counties) Morehead City District 400 Commerce Ave Morehead City, NC 28557 202-808-2808/ 1-888-4RCOAST Fax: 252-247-3330 (Serves: Carteret, Craven, Onslow -above New River Inlet- and Pamlico Counties) Washington District 943 Washington Square Mall Washington, NC 27889 252-946-6481 Fax: 252-948-0478 (Serves: Beaufort, Bertie, Hertford, Hyde, Tyrrell and Washington Counties) Wilmington District 127 Cardinal Drive Ext. Wilmington, NC 28405-3845 910-796-7215 Fax: 910-395-3964 (Serves: Brunswick, New Hanover, Onslow -below New River Inlet- and Pender Counties) Revised 06/29/05 wcS l 1"+1urr�gr & t RUST OXAPANY Shan-boro, NIC28524 �-` F(5ifarCRF+G9 �a ere*Pa I lE %ie 28�nCr 66-30/53i 12/12/2005 a_ C"t�ftF,/;—100.00 1 �iOT L ' JRr F-A OF ---- - - --- — - ---------- -� � GinC'_ HunGC', Li (Inc(�l o DOLLARS CAMu" %4EMO GP /Iff�) IL ill' 0C Georgia Ricks Murray CAMA (j(/ Fir5f ' --ens Checki GP Georgi icks Murray CAMA First Citizens Checki GP S3 Lul 1:0S31003001:0031, L7S9: 12/12/2005 3531 100.00 100.00 12/12/2005 3531 100.00 - I DM� L F U 1 2 2005 =u Morehea(j Ci4y Dm - 100.00 ,,...k . _. ." 526463 (9105) 0 ADJACENT RIPARIAN PROPERTY OWNER STATEMENT r I hereby certify that I own property adjacent to A�r. w rs. �h. Selma �a 's (Name of Property Owner) property located at 3 oc— tKt (� (Lot, Block, Road, etc.) on UDQIU.t , in Crk-e-,a�,ld �SG� �L J~%'1 , N.C. (Waterbody) (Town and/or County) He has described to me as shown below, the development he is proposing at that location, and, I have no objections to his propos _ -�- �� 4 ------------ ----- -- ---- -- - --------------- ---------------------------------------------------- DESCRIPTION AND/OR DRAWING OF PROPOSED DEVELOPMENT S(To be filled in by individual proposing development) 4iao,G,c— r" 1 r 7- N ZOU5 Morehead city DcM l�Eo R-{, I !i:� �t wrra ! i Print or Type Name S5t- -15Y -Soo -)- Telephone Number Date: Q - � - -�2�5 c 08 05 08:41 p Dec. 8. 2005 11:07PM NO. u'" r. AW ACENT WFARIAN PROPERTY OWNER ST ATEWNT 2 I rye I hereby certify that 1 own property adjacent to C k" Ig's 6 rowm ' 's 6-t� yL vI 9o-f 51 4Z (Name of Property Owner) property located at l-oC—*,c ro- U L4,%-c (Lot, Block, Road, p.1 on b , in ►n(,o-a,.E �. i 2 N L �5 rr- , N, C . - aterbody) (Town aa,cVbr County) He has described to me as shown below, thedevelopment he is proposing at fh blocations:: and, I have no objections to his proposal. . X---� ---=---'--G-- - - --c- - ------------------------- ----- DESCRIPTION AND/OR DRAWIIVG OF PROPOSED DEVELOPMtNT (To be filled in by individual proposing development) ig a e 0,.1I4-h=.C�.ac rxPr,� c 1 j - oreheEto City flaw &-4�o 0-4w 1 M ►vt -or-A 4-1 Print or Type Name 25Z- 3GY— 5b01— Telephonc Number Date: 1-L ' W - b 5 10 19 Retainin rr Wall Construction Plans Plan Sheet Index: S-1 Title Sheet & Gerenal Notes S-2 Retaining Wall Specifications S-3 Retaining Wall Site Layout S-4 Wall Profile S-5 Cross -Section A -A S-6 Retaining Wall Details *General Note * The Engineer requests that representatives of the owner and/or general contractor arrange a pre -construction meeting with all pertinent parties involved for the construction of the retaining wall shown on these plans. Unless indicated by a supplemental written contact, the Engineer responsibility is limited to providing only the design services of the project's retaining walls contained herein. Retaining wall construction monitoring, retaining wall certifying, etc. are beyond the scope of our original design services. The Engineer shall not be required to sign any documents, no matter by whom requested, in which the Engineer is required to certif ,, guarantee, or warrant the existence of conditions, the existence of which the Engineer has not or cannot ascertain. *Construction Notes* 1.) Confirm Distance from Property, line, Tree Buffer, Curb & Gutter and/or Buildings to Face of Proposed MSE Wall Prior to Construction. (Don't forget to include the batter of the wall.) 2.) Confirm Existing Utilities Locations (Stormwater, Sewer, Water, Electrical, & Gas) & Coordinate Future Utilities Locations Prior to Wall Construction. 3.) Confirm In -Situ and Proposed/Future Grades Prior to Wall Construction. 4.) Coordinate All Fence, Guardrail, Curb & Gutter, &/or Pavement Installation Prior to Construction,to Avoid Damaging Upper Layers of Reinforcement. N NO. REVISIC:V DATE \\11111111111t///�/ 1:Q MLI _ 030060 t INE�e •�Q ytp t F i O oo 0 0 "� � r3, z75) a g 1! E 4 x � U �z - U Q z W v N N o U c� z N � N z o z N O U Project 05-320-1195 A7 Date: 01 NOVENMER05 Scale: NTS Title Sheet & General Notes S-1 of 6 1.1 GENERAL SEGMENTAL RETAINING WALL SYSTEMS ARE DESIGNED AS A GRAVITY RETAINING WALL UTILIZING A HIGH DENSITY POLYESTER GEOGRID TO REINFORCE THE SOIL ZONE BEHIND THE WALL. THE GEOGRID IS POSITIVELY CONNECTED TO THE MODULAR CONCRETE BLOCK CREATING A REINFORCED SOIL MASS CAPABLE OF RESISTING LATERAL EARTH PRESSURES AND SURCHARGED LOADS. 1.2 QUALITYASSURANCE WORK SHALL BE PERFORMED ONLY BY AN EXPERIENCED CONTRACTOR WHO HAS SUCCESSFULLY INSTALLED A MINIMUM OF ONE HUNDRED THOUSAND SQUARE FEET OF RETAINING WALLS OR WHO HAS SUCCESSFULLY COMPLETED AT LEAST FIVE RETAINING WALLS OF EQUAL OR GREATER SCOPE. A.) CONTRACTOR SHALL SUBMIT TO THE ENGINEER, PRIOR TO START OF WORK, EVIDENCE OF QUALIFICATIONS AND REFERENCES ON PROJECTS OF SIMILAR SCOPE. EVIDENCE SHALL BE SUBMITTED IN WRITING TO THE ENGINEER ON THE CONTRACTOR'S LETTERHEAD AND SHALL CONTAIN AT A MINIMUM: 1) A LIST OF FIVE REFERENCE PROJECTS OF EQUAL OR GREATER SCOPE WITH CONTACT INFORMATION, 2) A LIST OF EXPERIENCE COMMENSURATE WITH THE PROJECT SCOPE (WALL DIMENSIONS, ERECTION TOLERANCES, SOIL PARAMETERS, AND MATERIALS). B.) ENGINEER SHALL REVIEW QUALIFICATIONS AND REPORT TO THE CLIENT ON THE SAME. ENGINEER RESERVES THE RIGHT TO REJECT ANY AND ALL QUALIFICATION SUBMITTALS, WHEN IN THE ENGINEER'S OPINION SUCH QUALIFICATIONS ARE DEEMED UNSATISFACTORY. ENGINEER'S APPROVAL OF CONTRACTOR'S QUALIFICATIONS SHALL NOT RELIEVE THE CONTRACTOR OF ANY OR ALL CONTRACT RESPONSIBILITIES FOR QUANTITIES, PERFORMANCE, OR OTHER REQUIREMENTS OF THE CONTRACT DOCUMENTS. ENGINEER'S APPROVAL OF CONTRACTOR QUALIFICATIONS SHALL NOT BE CONSTRUED AS A WARRANTY OR GUARANTEE OF THE CONTRACTOR'S WORK. C.) THE OWNER AND/OR GENERAL CONTRACTOR SHOULD PROVIDE A SPECIAL INSPECTOR AS A FULL-TIME CONTINUOUS MONITOR OF WORK QUALITY. THE SPECIAL INSPECTOR WILL REPORT BACK TO THE BUILDING OFFICIAL AND ENGINEER ON QUALITY AND PROGRESS OF WORK. THE SPECIAL INSPECTOR WILL REQUIRE TESTING BE DONE BEFORE THE WORK PROCEEDS. 1.3 BA CK FILL MA TERIALS THE SOIL MATERIAL ASSOCIATED WITH THE RETAINING WALL IN THE REINFORCED ZONE, THE RETAINED ZONE, OR THE FOUNDATION BEDDING SHALL HAVE THE FOLLOWING PROPERTIES: A.) FOUNDATION SOILS 0= 28 DEGREES, COHESION = 0 PSF, UNIT WEIGHT = 105 LBS/CU.FT. B.) RETAINED SOILS 0= 28 DEGREES, COHESION = 0 PSF, UNIT WEIGHT = 105 LBS/CU.FT. C.) REINFORCED SOILS 0= 30 DEGREES, COHESION = 0 PSF, UNIT WEIGHT = 120 LBS/CU.FT. THE SOILS CHARACTERISTICS ABOVE WERE ASSUMED BASED ON INFORMATION SUPPLIED TO THE ENGINEER. IF THIS INFORMATION DOES NOT REPRESENT THE ACTUAL SOIL TO BE USED, THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY AND THE WALL SHALL BE REDESIGNED. 1. 4 SEIS311IC DESIGN CRITERIA PEAK ACCELERATION = N/A VERTICAL ACCELERATION = NOA 1. S FOUNDA TION LOADS THE MAXIMUM APPLIED FOUNDATION LOAD FOR THIS WALL IS 2.0 KIPS/SQ.FT. 1.6 CONCRETE MASONRY WALL UNITS CONCRETE WALL UNITS SHALL BE SEGMENTAL UNITS MANUFACTURED IN ACCORDANCE WITH ASTM-C1372 AND ASTM C140 AND SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. UNITS SHALL BE INTERLOCKED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. TYPE OF BLOCK SPECIFIED FOR THIS PROJECT: KEYSTONE (COMPAQ. 1.7 GEOGRID REINFORCEMENT GEOSYNTHETIC REINFORCEMENT SHALL CONSIST OF HIGH TENACITY GEOGRIDS OR GEOTEXTILES MANUFACTURED FOR SOIL REINFORCEMENT APPLICATIONS. THE TYPE, AND PLACEMENT LOCATION OF THE REINFORCING GEOSYNTHETIC SHALL BE AS SHOWN ON THE PLANS. TYPE OF GEOGRID SPECIFIED FOR THIS PROJECT: SYNTEEN 35. 1.8 WALL BATTER BATTER FOR THE ENTIRE WALL SHALL BE MAINTAINED AT 1" SETBACK. 2.0 FOUNDATION REQUIREMENTS THE FOUNDATION BEARING CAPACITY THAT WAS ASSUMED FOR DESIGN SHALL BE VERIFIED IN THE FIELD, AND COPIES OF THE TEST DATA FILED WITH THE ENGINEER. THE FOOTING SHALL BE CLEARED OF LOOSE SOIL. A MINIMUM OF 12" OF WASHED STONE SHALL BE PLACED AT THE BACK OF EACH BLOCK AS INDICATED ON THE DETAILS. 2.1 LEVELING PAD MATERIAL SHALL CONSIST OF COMPACTED SAND, GRAVEL, CRUSHED ROCK,WASHED STONE, OR UNREINFORCED CONCRETE. THE PAD SHALL BE 6" THICK (UNO). SAND OR GRAVEL MATERIAL SHALL BE COMPACTED TO 95% STANDARD PROCTOR. AGGREGATE MATERIAL SHALL RECEIVE A MINIMUM OF ONE PASS OF THE COMPACTION EQUIPMENT. THE TOP OF THE LEVELING PAD FOR THE WALL SECTIONS SHALL BE MAINTAINED AT A MINIMUM DEPTH OF 10% OF TOTAL WALL HEIGHT OR MORE(6" MIN.) (UNO). 2.2 UNIT FILL THE VOID WITHIN EACH UNIT SHALL BE FILLED WITH A WASHED STONE (#57 STONE) HAVING 100% OF THE AGGREGATE PASSING THE 2" SIEVE. A MINIMUM OF 3/8" WASHED STONE SIZE IS REQUIRED (NO MORE THAN 5% PASSING THE #200 SIEVE). THIS SAME MATERIAL SHALL BE PLACED BEHIND EACH BLOCK PER SEC. 2.0. ALL EXCESS MATERIAL SHALL BE SWEPT CLEAN FROM THE TOP OF THE BLOCK PRIOR TO INSTALLING THE NEXT COURSE, EACH COURSE OF BLOCK SHALL BE COMPLETELY FILLED BEFORE PROCEEDING TO THE NEXT COURSE. 2.3 CADS APPLY A CONSTRUCTION ADHESIVE TO THE UNITS TO PREVENT THEIR REMOVAL. 2.4 FIRST BLOCK COURSE THE FIRST COURSE OF BLOCK SHALL BE PLACED ON TOP OF AND IN FULL CONTACT WITH THE LEVELING PAD. THE UNITS SHALL MAINTAIN A DISTANCE OF MINIMUM 6" FROM THE FRONT AND BACK OF THE LEVELING PAD. PROPER ALIGNMENT MAY BE ACHIEVED WITH THE AID OF A STRING LINE. PROCEED TO THE NEXT COURSE OF BLOCK. EACH UNIT SHALL CONTACT THE UNITS ON BOTH SIDES AS WELL AS ABOVE AND BELOW. SOME ADJUSTMENTS MAY BE REQUIRED FOR WALLS WITH CURVES AND A BATTER. 3.0 GEOGRID INSTALLATION THE GEOGRID REINFORCEMENT SHALL BE LAID HORIZONTALLY ON COMPACTED BACK FILL AND CONNECTED TO THE CONCRETE WALL UNITS, IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. GEOGRID SHALL BE PULLED TAUT REMOVING ALL SLACK FROM THE MATERIAL AND ANCHORED BEFORE ADDING FILL. GEOGRID SHALL BE INSTALLED AT THE ELEVATIONS AND LENGTHS REQUIRED AS SHOWN ON THE PLANS (REFER TO DETAILS FOR THE APPROPRIATE ORIENTATION). SOIL SURFACE SHALL BE SMOOTH AND LEVEL AND HAVE BEEN COMPACTED TO 95% STANDARD PROCTOR BEFORE INSTALLING THE GRID. 3.1 FILL PLACEMENT BACK FILL MATERIAL SHALL BE PLACED ON A MAXIMUM 8" COMPACTED LIFT, 95% STANDARD PROCTOR WITH A MOISTURE CONTROL OF +/- 3% OF OPTIMUM. ONLY HAND OPERATED EQUIPMENT SHALL BE ALLOWED WITHIN 3 FEET OF THE SEGMENTAL UNITS. BACK FILL SHALL BE PLACED FROM THE WALL REARWARD TO INSURE TAUTNESS OF THE CEOGRID. CONSTRUCTION EQUIPMENT SHALL NOT BE OPERATED DIRECTLY ON THE GEOGRID. 3.2 UNSUITABLE MATERIAL SOILS CONTAINING ROOTS, BRUSH, SOD OR OTHER ORGANIC MATERIAL SHALL NOT BE PERMITTED AS BACKFILL FROZEN SOILS, SNOW, ICE, HEAVY CLAYS, OR WET SOILS SHALL NOT BE PERMITTED AS BACKFILL. MATERIAL PASSING THE #40 SIEVE SHALL NOT HAVE A LIQUID LIMIT OF GREATER THAN 40 AND A PLASTICITY INDEX OF GREATER THAN 15, UNLESS WRITTEN CONSENT IS OBTAINED FROM THE ENGINEER PRIOR TO PLACEMENT. 3.3 SOIL PROPERTIES MINIMUM INTERNAL ANGLE OF FRICTION SHALL EQUAL OR BE GREATER THAN REFERENCE IN SECTION 1.3. VERIFICATION SHALL BE FILED WITH THE ENGINEER THAT THE SOIL WILL MEET THIS CRITERIA. 4.0 SOIL TESTING COMPACTION TESTING SHALL BE PERFORMED FOR EVERY LIFT ELEVATION REQUIRING GEOGRID OR EVERY 3RD LIFT AS A MINIMUM. TESTS SHALL BE FILED WITH THE ENGINEERS OFFICE. S. 0 HYDROSTATIC PRESS URE POTENTIAL THE ENGINEER SHALL BE NOTIFIED IF ANY OF THE FOLLOWING SHOULD BECOME EVIDENT: -WATER OR WETNESS FROM OR IN A CUT BANK -LOCAL SPRINGS, LOCAL STORM DRAINS, SEWER, WATER LINES UNDER OR BEHIND THE WALL 6.0 ACCEPTABLE BLOCK SEGMENTAL UNITS SHALL BE USED AND KEPT FREE OF DEFECTS THAT WOULD INTERFERE WITH THE PLACING OR POSITIONING OF THE UNIT OR IMPAIR ITS STRENGTH, MINOR CRACKS INCIDENTAL TO THE USUAL METHOD OF MANUFACTURING OR MINOR CHIPPING RESULTING FROM SHIPMENT AND DELIVERY ARE NOT GROUNDS FOR REJECT 7.0 ACCEPTABLE GEOGRID GEOGRID SHALL BE REJECTED IF 20% OR MORE OF A STRUCTURAL RIB HAS BEEN CUT OR RIPPED. THE CONTRACTOR SHALL INSPECT ALL GEOGRID DELIVERED TO THE SITE AND REJECT MATERIALS THAT MEETS THIS CRITERIA. IF THE GEOGRID IS DAMAGED ON THE CONSTRUCTION SITE, IT SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE, 8.0 DRAINAGE COMPOSITE (APPLIES TO CUT WALL APPLICATIONS ONLY), WHERE SITE CONDITIONS WARRANT DRAINAGE COMPOSITE SHALL BE INSTALLED TO COVER 30% OF THE CUT BEHIND THE GEOGRID LAYERS. STRATA -DRAIN (6FT. WIDE SECTIONS) PROVIDES 30% COVERAGE WHEN INSTALLED ON 15 FT CENTERS AND 2/3 THE WALL HEIGHT. 9.0 SPECIAL PROVISIONS A.) GENERAL CONTRACTOR SHALL COORDINATE UPPER GEOGRID LAYERS INSTALLATION W/ PAVING INSTALLATION. B.) MAINTAIN THE DIRECTION OF DRAINAGE AWAY FROM THE WALL FACE AT ALL TIMES DURING CONSTRUCTION OF THE WALL AND FINISH GRADING AS SHOWN ON PLANS. C.) PLACEMENT OF GEOGRID SHALL BE AS PER PLANS, W/ REGARDS TO PLAN SPECIFIED LENGTH & ELEVATIONS. D.) THE ENGINEER SHALL BE NOTIFIED BY THE INSTALLING CONTRACTOR SHOULD THE EMBEDMENT DEPTH OF THE WALL BE LESS THAN 10% OF THE TOTAL WALL HEIGHT (6" MIN.) (UNO). E.) THE REINFORCED SOIL IS ASSUMED TO BE: SC, SM, SP, SW, & ETC. (HIGH PLASTICITY SILTS AND CLAYS) ARE NOT ACCEPTABLE. F.) PER NORTH CAROLINA BUILDING CODE, A BUILDING PERMIT MUST BE OBTAINED PRIOR TO WALL CONSTRUCTION. CONTACT YOUR LOCAL CITY, COUNTY, MUNICIPALITY, OR TOWN CODE ENFORCEMENT TO OBTAIN BUILDING PERMIT. G.) THE DESIGN ENGINEER'S LIABILITY IS LIMITED TO THE COST OF THE DESIGN SERVICES FOR THE WALLS. 10.0 QUALIFICATION OF DESIGN A.) STABILITY OF ANY TEMPORARY SLOPES REQUIRED BY THE INSTALLATION OF A SEGMENTAL RETAINING WALL SHALL BE ADDRESSED BY A QUALIFIED GEOTECHNICAL ENGINEER. RESPONSIBILITY OF THESE TEMPORARY SLOPES RESTS WITH THE OWNER AND/ OR ARCHITECT OF THIS PROJECT AND THE SLOPES SHALL MEET ALL OSHA STANDARDS OF MAX. SLOPE STEEPNESS= 1.5H:lV. B.) HANDRAIL/ GUARDRAIL REQUIREMENTS SHALL BE DETERMINED BY THE ARCHITECT OR GENERAL CONTRACTOR. C.) NOTIFY THE DESIGN ENGINEER PRIOR TO MODIFYING WALL CONSTRUCTION IF EXISTING SITE CONDITIONS DEVIATE FROM CONDITIONS OUTLINED ON RETAINING WALL PROFILE. NO. REVISION DATE HAL ' 030060 _ �l G l' 'H � � N d• cp U 00 Z x � o, `a o � C, v, L 0 y H g o �1 00 ti q 4� C� � U � �z 0 .o b � wQ b E W 0 a `11 o, 00 o U � � �zN� U 2 u z U 49 o N O z U 1/1 Project: 05-320-1195 W Date: 01 NOVEMBER05 Scale: NTS Retaining Wall Specifications S-2 of 6 Client Name and Address Trim Landscaning- 264 Rollingwood Drive Newport, NC 28570 Office: (252) 726-2909 Mobile: (252) 723-8746 Cn + O O ZZ Project Name and Paul Murrav Residence 8738 Emerald Plantation Road Emerald Isle, Carteret County, NC C N � N � 00 H- h— and Add— D. Miller & Associates,PA 8504 Six Forks Road, Suite 101 Raleigh North Carolina 27615 Office: (919) 846-9202 Fax: (919) 846-0246 Questions Call: (919) 369-0618 I� 0 d m F�N-1-0 REVISION DATE t 11 1 ■ ■ RINI. ■ ILI .0 l 0010 • • • ct rfikwal • • t fi 7 " �= �r• e9irieisirivtmAlvwn ii- Jii■■!!!i■■il�lii!llwiil�liil�! ■■ i ■■!}liii!1'� ■iiii!■■i!�!i■■!�i ■■i!*liiiCl'liilllwi■ il/riii'iiiiiiiriiliiilriiili i i iiariiiiiiidiiiiiaiii ii■iiiiiiiiiiiiiiilii }liiilTJiii:lliilllii!!liilT. ■■ i i!*liiiT!■■i■■iliilflii■.T,i ■■i!*liii�}liill!■■■ ii■iiil'iiiiiCiiiiiliiriiiiii'ii i iiii■■iiiiiiiiiliiiKaiiiii■iiiii■■liiiiiiiirii ri■iil�9iiiT!■i■■!!liillGliilT.■wii!*liii:Tliilllwiil�lii!}liii!}liii!*liillli■ iiriiiiiiii7iiiHiiiiiiriill�iiilaiiiiiiiiliiiiiiiari■siiriiiiriiiGili�''�i ■1liil7liil7!!ai!}liil;!!■iil1�■iil11ii!}ii■■!}liii"!!ii!!!■iilliiw��i■■ii: iiliiiiiiaiiiiaiiiliiiiiiiiiiliiiii�iiiiaiiiiiriiiliiiiiliir�a�iii�i�•r_--� ■!}liiil!■■il�Ilii!}iii!}liiillJiiiTlw■illlli■■l7ii■■!/liii!w_���iii! i iris-r_ ��� �'-'�= ��*�•- �:/=�-r=r=�-� iii��--�-'�-`-'- ��''• =*-• iiaiiiiiiiiiNiii'liiiiisiiiiiiiiiiiiiiiiiiiaiiriiiliii�liili ■!*!w■it111iilR■■ii!*!ii■■E!!ii■l7liill'liil�i■■il�l�i77��=--•�-=--� iiiiiiriiiriri'i■iiiili■iiiIi7iiiliiiiiiiCiliiiy��iiiiii_ Aiii!*liii*liillrl77!*iiil�!■■ii_R!_i�s*!i!■■ii�irc ■ETliiil!■■illy!■■■■lTiii■1'liw� :_='•='•� ■!*iiil�Jiii!!!w■w��rliiiiiireT iii■iiiiii���iiiiiliii��--�=�=r:.:i NO. REVISION DALE Existing Dwelling I I-1 I I Retained Soil Cross -Section A -A I —I i t—I 11-1 11-1 IT= I —III —I TT—`fry--S,�7 1-1 1=1 I I-11 I=1 11— =1 i i-i I MI 11=1 _I I IS I a I 1—I I I=1 I I-1 I I_I I I —I I I_ 1I- -111—� Existing Timber Wall -I (To Be Removed by Others or to Remain in Place) Distance Varies 26'-0" Min. Railing or Fence By Others 1.) Per -Cut Geogrid @ Post locations 2.) Place in Concrete T-0" Min. 8" Min. Low Permeable Soil /��// •"t''•'-7•' 95%Compacted I /95%CompactedBackfill + +�:35+ ;+-r�� 35 35 (28° Material or Better) 77 " t : : •: '.'; Reinforced Backfill jQO' Material or Better _."w#-'''39 ..=. '33 •ram. 35'`'. .:.,3 _.3 II1�1.1I—III—III—Ir35'.`.��:.''3..-� —III— i III III—.�.:-�-;•.'::;;�.._.::_,:�:'"�,�:;=.:...,�::.•:�,'— III-1 I& I-1 11=1 I I-1 I III I I. III —I I I�I i—III III I I I I —� 4" Perforated Drain - Required -1 1 I=I I — (Gravity drain to thIVIlowest point along the wall =1 I I=1 I with outlets every 45ft. and at the ends of the wall.) =III—III—III—II1=1II—II1 —II1=1 - III—III—III=III=III—III—III f—III— -I I I -I I f=1 11=1 11=1 11=1 11�1 I I� I I -I I I Reinforced Wall Section 8" Segmental Units - V Setback Swale - Required (Gravity drain to end of wall and/or drainage structure) Cap Unit i-- 22" Max. Setback = I I —I I —(I 1—I 11—(1�_ Bearing Pressure = 2.( ksf o be confirm by Geotechnic d Engineer) -1 1 1-1 1 1-1 1 1=1 1 1-1 1 1= l i Foundation Soil i I I I I I 1=1 11=1 11= Retaining Wall Construction Criteria Table Wall Height Range Geogrid Length Min. Washed Stone Min. Bearing Pressure Min. Embedment (31ax. to Min.) & Type Required Behind Wall Required Required Notes /Remarks All Layers = 11.0' 15'-8" thru 12'-4" Synteen 35 or Equiv. 12 Inches 2.0 ksf 16 inches See profile for eo id placement. P g €r 12'4'' thru 8'-4° All Layers = 9.0' Synteen 35 or Equiv. 12 Inches 2.0 ksf 12 inches See profile for eo id placement. P g 8'4" or Less All Layers = 7.0' Synteen 35 or Equiv. 12 Inches 2.0 ksf 8 inches See profile for eo id placement. P g Height, Varies 15'-8" Max. 95% Compacted Fill -I I I=1 I I —I 11-1 I MI I I -I I I -I I I=1 I �: 6" Min. Crushed or III—WI1 III1Sto1I1 1I1=1 -I I MI 11=1 I I-= I I-1 1I— I I —I I I —I 11=1 11-i I I=1 -I I I —I I I —III —III —I I �_ =1 I I=1 I I-III-III=1 \\\��11111111111///// CA RO t� SEAL i 030060 GINE�,..'�Q \\: F L P�'P��``� •-- kr) [� cV 00 .� CIA N i% o O yy 00 U ^ oo Z O O ' mil- U Ol ` O kn 00 "s q yid U U E O� z 'V x U (�{ U 0 �q��OF OF V oG O N N o U t` �z t^N O l O �J z . ►v V Project 05-320-1195 W Date 01 NOVENIBER 05 Sca1e 1" = 10' Reatinirlg Wall Site Layout S-5 of 6 Base Leveling Pad Notes: 1. The leveling pad is to be constructed of crushed stone or 2,000 psi± unreinforced concrete 2.The base foundation is to be approved by the site geotechnical engineer prior to placement of the leveling pad. Excavation Limits 6" Crushed Rock or Unreinforced Concrete Leveling Pad 8'' Segmental Unit 4" Cap Unit Width: 18" Width: 18" *Depth: 12" *Depth: 101/2" Height: 8" Height: 4" `'Weight: 85lbs *Weight: 45lbs Segmental Unit/Base Pad Isometric Section View Dimensions & Weight May Vary by Region Place Additional Pieces of Geogrid When Angle Exceeds 20' 3" of Soil Fill is Required Between Overlapping Geogrid for Proper Anchorage (Typ.) Additional Drainage Fill Extend Wall Height / 2 7 H/2 H/2 I I 3" of Soil Fill is Required Between Overlapping Geogrid for Proper Anchorage (Typ.) Additional Drainage Fill Extend Wall Height / 2 7 H/2 'J�rX; H/4 Drainage Fill Note: 1, Check with manufacturer specifications on correct direction of orientation for geogrid to obtain proper strength. Geoarid Installation on Curves H /4 Additional Geogrid Overlap Extend Wall Height / 4 Drainage Fill Note: 1. Check with manufacturer specifications on correct direction of orientation for geogrid to obtain proper strength. 2. Corner units recommended for outside comers. Availability May Vary. Geogrid Installation at Corners (2) - 4" Cap Units or (1) - 8" Cap Unit 4" Cap Unit S�" Ccnmontal Backfill or Concrete Post in Place Steel Fence or Railing •s • s Note: 1. Secure all yap units with Kapseal or equal Fence Plan Top of Wall Steps Detail V VI UJI IGU 1\Vlri`� vi - -' - Unreinforced Concrete Step Leveling Pad Elevation Note: 1. The leveling pad is to be constructed of crushed stone or 2000 psi ± unreinforced concrete. 6" W (Zct-finn Leveling Pad Detail 3' Min. Keystone 4" Cap Unit Keystone Compac Unit Backfill or Concrete J Geogrid Fence SectionDetail Compac Unit - Near Vertical Setback _c Ul iv w w uc vfm�u v1 i lcvcl backfill and extended over the unit. Place next unit. Pull grid taught and backfill. Stake as required. Grid Placement I } Cap Unit Elevation Cap Unit Plan Universal Cap Unit Option 00 Block Elevation 18" Block Plan Segmental Unit Cap Unit Elevation Cap Unit Plan 3-Plane Split Cap Unit Option FLO REVISION DATE \0\\\1IIII/I///// E A R o / .a SAL ' 430060 F'yG INE•C�P p l F L PNP���`� •V � � N a tf O 44 oho, � wz O o4 • a; q V 0C o U � � z N o�� O �z U U Project 05-320-1195 W Date: 01 NOVEMBER 05 Scale NTS Retaining Wall Details S-6 of 6