Loading...
HomeMy WebLinkAbout30522_TOWN OF RIVER BEND_20011120C,CAMA / El DREDGE &FILL i " � C �����l�,( GENERAL .'HERMIT Previou�ef`mit# G �'" P C�New ❑Modification — Complete Reissue ❑Partial Reissue Date previous permit issued As authorized by the State of North Carolina, Department of Environment and Natural Resources and the Coastal Resources Commission in an area of environmental concern pursuant to I SA NCAC ❑ Rules attached. Applicant Name * a t', Project Location: County c r Address Street Address/ State Road/ Lot #(s) State ZIP .:-A I Phone # ( ) Fax # O Authorized Agent Affected ❑ CW G EW L PTA ❑ ES PTS AEC(s): ❑ OEA E HHF ❑ IH ❑ UBA `I N/A ❑ PWS: ❑FC: ORW: yes / no PNA yes /rn6) Crit. Hab. yes /?,,no Type of Project/ Activity Subdivision ZIP City - F, ,�� ; .,.-. Phone # ( ) River Basin Adj. Wtr. Body �.'tc (�� (nat /6ian /unkn) Closest Maj. Wtr. Body , v C r (Scale: ) Pier (dock) length Platform(s) Finger pier(s) Groin length number Bulkhead/ Riprap length avg distance offshore max distance offshore Basin, channel cubic yards Boat ramp Boathouse/ Boatlift Beach Bulldozing Other Shoreline Length SAM not sure yes no Sandbags: not sure yes no Moratorium: n/a yes no Photos: yes no Waiver Attached: yes no A building permit may be required by: See note on back regarding River Basin rules. Notes/ Special Conditions /v F � � f ' ( � f , /s r,, % /1 } 4 Agent or Applicant Printed Name f Ag ppli�"Permit Officer's Signature Signature 'Please read compliance statement on back of permit" Issuing Date Expiration Date Application Fee(s) Check# Local Planning Jurisdiction Rover File Name Statement of Compliance and Consistency This permit is subject to compliance with this application, site drawing and attached general and specific conditions. Any violation of these terms may subject the permittee to a fine or criminal or civil action; and may cause the permit to become null and void. This permit must be on the project site and accessible to the permit officer when the project is inspected for compliance. The applicant certifies by signing this permit that 1) prior to undertaking any activities authorized by this permit, the applicant will confer with appropriate local authorities to confirm that this project is consistent with the local land use plan and all local ordinances, and 2) a written statement or certified mail return receipt has been obtained from the adjacent riparian landowner(s) . The State of North Carolina and the Division of Coastal Management, in issuing this permit under the best available information and belief, certifythat this project is consistentwith the North Carolina Coastal Management Program. River Basin Rules Applicable To Your Project: ❑ Tar - Pamlico River Basin Buffer Rules ❑ Other: [� Neuse River Basin Buffer Rules If indicated on front of permit, your project is subject to the Environmental Management Commission's Buffer Rules for the River Basin checked above due to its location within that River Basin. These buffer rules are enforced by the NC Division of Water Quality. Contact the Division of Water Quality at the Washington Regional Office (252-946-6481) or the Wilmington Regional Office (910-395-3900) for more information on how to comply with thesebuffer rules. Division of Coastal Management Offices Central Office Elizabeth City District Mailing Address: 1367 U.S. 17 South 1638 Mail Service Center Elizabeth City, NC 27909 Raleigh, NC 27699-1638 252-264-3901 Location: Fax: 252-264-3723 Parker -Lincoln Building 2728 Capital Blvd. Raleigh, NC 27604 919-733-2293 / 1-888ARCOAST Fax:919-733-1495 (Serves: Camden, Chowan, Currituck, Dare, Gates, Pasquotank and Perquimans Counties) Morehead City District 151-B Hwy. 24 Hestron Plaza II Morehead City, NC 28557 202-808-2808 Fax: 252-247-3330 (Serves: Carteret, Craven, Onslow -above New River Inlet- and Pamlico Counties) Washington District 943 Washington Square Mall Washington, NC 27889 252-946-6481 Fax: 252-948-0478 (Serves: Beaufort, Bertie, Hertford, Hyde, Tyrrell and Washington Counties) Wilmington District 127 Cardinal Drive Ext. Wilmington, NC 28405-3845 910-395-3900 Fax: 910-350-2004 (Serves: Brunswick, New Hanover, Onslow -below New River Inlet- and Pender Counties) Revised 10/05/01 6261 AVOLIS ENGINEERING, P.A. FIRST PO BOX 15564 5405 MORTON RD NEW BERN, NC 10/29/01 NEW BERN, NC 28561 66-301531 252-633-0068 * * 100.00 PAY TO THE NCDENR-COASTAL MANAGEMENT ORDER OF Onc Hundred and 00/100 *************************************+************************************************** DOLLARS NCDENR-COASTAL MANAGEMENT 1 1 MEMO: RIVER BEND - STORMWATER 6P�e-30 SZ Z 006267n■ 1:053L00300i:O0LLL2439279' .I 11 , . 1111 I'Af II 1111 AIIIII II'I V'AII IIMI IN 111I I11 VI i 1i 11 1 Ii,unlrlulll, ll;n1-a'� AVOLIS ENGINEERING, P.A. P,O, Box 15564 • New Bern, North Carolina 28561 • (252) 633-0068 October 12, 2001 Mr. Scott Jones 01 Z091 CAMA Office 151-B Highway 24, Plaza II Hestron Building Morehead City, NC 28557 RE: Stormwater Improvements, Town of River Bend AE Project No. 01042 Dear Scott: I appreciate the opportunity to discuss the proposed drainage improvements at River Bend with you. Per our discussion, it is my understanding that a General CAMA Permit will be issued for the project. Per our discussion, attached please find the following information relative to issuance of a General CAMA Permit for this project: 1. Executed Bridges and Culverts section of the CAMA Major Permit Application. 2. Proof of Notification of Adjacent Riparian Property Owners 3. $100.00 Permit Fee It is my understanding that one set of project plans is required for this submittal, and these were previously submitted. It is requested that a CAMA General Permit be issued for this project at your earliest convenience. Should you have any questions relating to this matter or need any additional information, please do not hesitate to call. Sincerely, evin Avolis, P.E. ice -President 1 40L_ Ycu A,� D ADJACENT PROPERTY OWNER STATEMENT NOV 0 1 2001 I hereby certify that I own property adjacent to Town of River Bend `s (Name of Property Owner) property located at Shoreline Drive Right -of -Wad , on (Lot, Block, Road, etc.) Harbor Town Lake in River Bend , North Carolina. (Waterbody) (Town and/or County) He has described to me, as shown below, the development he is proposing at that location and I have no objection to his proposal. DESCRIPTION AND/OR DRAWING OF PROPOSED DEVELOPMENT: (To be filled in by individual proposing development) Signature Salo 1Lc1��ow Name a5a.- (fl$3--LRLo3 Phone Number ►o- a t -ol Date ADJACENT PROPERTY OWNER STATEMEN*0 V 0 1 2001 I hereby certify that I own property adjacent to Town of River Bend `s (Name of Property Owner) property located at Lochbridge Drive , on (Lot, Block, Road, etc.) Town Lake in River Bend , North Carolina. (Waterbody) (Town and/or County) He has described to me, as shown below, the development he is proposing at that location and I have no objection to his proposal. DESCRIPTION AND/OR DRAWING OF PROPOSED DEVELOPMENT: (To be filled in by individual proposing development) Signature Name Phone Number /O-Z� a/ Date CERTIAMARK 111111111111111111111 NOV 01 2001 O ;E'' NEWW BERNNC .NC 28561 OCT 18.'01 ao:...sonvi RMOUNT 0000 $4.86 28562 00079902-06 re S N)-) rrned Pi Io�as) o1- ?LI T" 8-K'Cej - AVULlS LNUINLLlUNU. Y.A. P.O. Box 15564 • New Bern, North Carolina 28563 n RoX,28562 o�d0�°` a Mor.d•�s" "° Ads` � �a"od O Reh+Md ueUAttemPted-Not Knot^ p N° SUen StMMONumbes 13 VWmt ❑ "'soft" O No µoil RsesP"c" O Boa Clossd-- Olds' a RMRMd W Ballot AddsesS spa 00 00 04 i O ° N U > I� u1 o 00 0 N rru N N CF to p -- m m o Z 3 Z m C Q) n `r ° f6 (D o z C3 r o X C3 O Q Q] O M a R- IF o I r ms 1, 2, and 3. Also complete sash tricted Delivery is desired. me and address on the reverse an return the card to you. E m Z ard to the back of the mailpiece, f71 nt if space permits. 41: -9 to: w 6 JN N -� dI ls(Ar� Pr,Cn DrE �;ne, A ReceNed by (Please Print Cleary)' B. Date of Delivery C. Signature ❑ Agent X ❑ Addressee D. Is delivery address different from item 1? ❑ Yes If YES, enter delivery address below: ❑ No �A tic U \t n o ` rii 1 C', a c q J L Z.. m y, 3. Service Type ECedified Mail ❑Express Mail ❑ Registered ❑ Return Receipt for Merchandise ❑ Insured Mail Cl C.O.D. 4. Restricted Delivery? (Extra Fee) El Yes a a mg my ¢¢ p ;pr: IJ"I labe0 rt 'N - '[oqg 3�1DO o011 o a15 C d ? a 2 m a 3 - service c a'� �m J 102595-01-M-142< 2001 Domestic Return Receipt �sdi ,March 5T2h 6E90 TTOO OOhE 660L hto , u V 0 ` 200, 4 . Form DCM-MP-5 BRIDGES AND CULVERTS Attach this form to Joint Application for CAMA Major Permit, Form DCM-MP-1. Be sure to complete all other sections of the Joint Application that relate to this proposed project. 1. BRIDGES Not Applicable a. Public Private b. Type of bridge (construction material) c. Water body to be crossed by bridge d. Water depth at the proposed crossing at MLW or NWL e. Will proposed bridge replace an existing bridge? Yes No If yes, (1) Length of existing bridge (2) Width of existing bridge (3) Navigation clearance underneath existing bridge (4) Will all, or a part of, the existing bridge be removed? (Explain) f. Will proposed bridge replace an existing culvert(s)9 Yes No If yes, (1) Length of existing culvert (2) Width of existing culvert (3) Height of the top .of the existing culvert above the MHW or NWL (4) Will all, or a part of, the existing culvert be removed? (Explain) g. Length of proposed bridge h. Width of proposed bridge i. Height of proposed bridge above wetlands j. Will the proposed bridge affect existing water flow? Yes No If yes, explain k. Navigation clearance underneath proposed bridge 1. Will the proposed bridge affect navigation by reducing or increasing the existing navigable opening? Yes No If yes, explain m. Will the proposed bridge cross wetlands containing no navigable waters? Yes No If yes, explain n. Have you contacted the U.S. Coast Guard concerning their approval? Yes No If yes, please provide record of their action. Revised 03/95 Form DCM-MP-S j. Will the proposed culvert affect existing navigation 2. CULVERTS potential? Yes x No If yes, explain a. Water body in which culvert is to be placed Harhnr Tnwn T.aka/Tnwn T.aka b. Number of culverts proposed 2 Each Location c. Type of culvert (construction material, style) 3. EXCAVATION AND FII.L Corrugated Steel Pipe a. Will the placement of the proposed bridge or culvert require any excavation below the MHW or NWL? d. Will proposed culvert replace an existing bridge? Yes x No Yes x No If yes, If yes, - (1) Length of area to be excavated (1) Length of existing bridge (2) Width of area to be excavated (2) Width of existing bridge (3) Depth of area to be excavated (3) Navigation clearance underneath existing (4) Amount of material to be excavated in cubic bridge yards _ (4) Will all, or a part of, the existing bridge be Excavation will be completed on uplan;-, removed? (Explain) b. Will the placement of the proposed bridge or culvert require any excavation within: _ Coastal Wetlands _ SAVs , Other Wetlands If yes, No e. Will proposed culvert replace an existing culvert? (1) Length of area to be excavated x Yes No (2) Width of area to be excavated If yes, (3) Amount of material to be excavated in cubic (1) Length of existing culvert 6 5 ' / 8 2 ' yards (2) Width of existing culvert 6 0 71 (3) Height of the top of the existing culvert above c. Will the placement of the proposed bridge or culvert the MHW or NWL 4. 9' /5. 3' require any highground excavation? (4) Will all, or a part of, the existing culvert be x Yes No removed? (Explain) If yes, All removed at Town Lake (1) Length of area to be excavated 74 None at Lochbridge 17rive (2) Width of area to be excavated 10 (3) Amount of material to be excavated in cubic f. Length of proposed culvert 6 2 ' / 1 2 0 ' yards 1 8 5 CY g. Width of proposed culvert 1 12 81 " d. If the placement of the bridge or culvert involves any excavation, please complete the following: h. Height of the top of the proposed culvert above the (1) Location of the spoil disposal area MHW or NWL 73"/84" Material will be used to Elevate (2) Dimensions of spoil disposal area Road i. Will the proposed culvert affect existing water flow? 800 LF x 40 LF Shoulders Yes x No (3) Do you claim title to the disposal area? If yes, explain x Yes No If no, attach a letter granting permission from the owner. Revised 03195 Form DCM-MP-5 (4) Will the disposal area be available for future maintenance? Yes x No (5) Does the disposal area include any coastal wetlands (marsh), SAVs, or other wetlands? Yes _ x No If yes, give dimensions if different from (2) above. (6) Does the disposal area include any area below the MHW or NWL? Yes x No If yes, give dimension if different from No. 2 above. Will the placement of the proposed bridge or culvert result in any fill (other than excavated material described in Item d. above) to be placed below MHW or NWL? Yes X No If yes, (1) Length of area to be filled (2) Width of area to be filled (3) Purpose of fill Will the placement of the proposed bridge or culvert result in any fill (other than excavated material described in Item d. above) to be placed within: Coastal Wetlands _ SAVs — Other Wetlands If yes, NO (1) Length of area to be filled (2) Width of area to be filled (3) Purpose of fill g. Will the placement of the proposed bridge or culvert result in any fill (other than excavated material described in Item d. above) to be placed on highground? x Yes No If yes, (1) Length of area to be filled 800 LF (2) Width of area to be filled 40 (3) Purpose of fill To elevate road shoulders 4. GENERAL a. Will the proposed project involve any mitigation? Yes x No If yes, explain in detail N U V 0 1 10U'I b. Will the proposed project require the relocation of any existing utility lines? Yes x No If yes, explain in detail C. Will the proposed project require the construction of any temporary detour structures? Yes x No If yes, explain in detail d. Will the proposed project require any work channels? Yes x No If yes, complete Form DCM-MP-2 e. How will excavated or fill material be kept on site and erosion controlled? _ S; I t EenrP Seedwav Mulching, Sodding f. What type of construction equipment will be used (for example, dragline, backhoe or hydraulic dredge)? Backhoe, Excavator, Dump ruc ra er g. Will wetlands be crossed in transporting equipment to project site? Yes x No If yes, explain steps that will be taken to lessen environmental impacts. h. Will the placement of the proposed bridge or culvert require any shoreline stabilization? X Yes No If yes, explain in detail Existing wood retaining wall being replaced with newly aligned vinyl retaining wall James W. Findley, Mayor Ap licant or Project Name - R i v o r Ben ci signature lab)h )� Date Revised 03/95 UNITED STATES POSTAL SERVIC&R, -- First -Class. ll Po8p?,,Q..$ Fees Paid PM ;,.• usPS..,..�_ �' Fierreiif ffo C-11D V. 20 OCT c„ • Sender: Please prin our BBCn A' ddress, Wt8 ZIP+4.- in this box""' NVO� �5 G Ifs ► h@e.r1�1 Q.1'"r. t�3ox I s s (6 4 NeW Be.rrN, O.C. a•IS 111111111it1)tIfIIII 111lll,ltl!lIdfi llllt1t111111ifI,111t:III ■ Complete items 1, 2, and 3. Also complete item'4 if Restricted Delivery is desired. ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card to the back of the mailpiece, or on the front if space permits. 1. Article Addressed to: Re,(- Po, 4 ('v�nelr 5 Assc Chv Eav- 6arcL ��Ve -:�$ Q►er Paine New &-yn, N.C. d4?S102 i A. Received by (Please Print Clearly) I B. Date of Delivery C. Sig a ure �'� —j X ❑ Agent ❑ Addressee D. Is delivery address different from item 1 ? ❑ Yes If YES, enter delivery address below: ❑ No NOV 0 1 2001 3. _Sere e Type O Certified Mail ❑ Express Mail ❑ Registered ❑ Return Receipt for Merchandise ❑ Insured Mail ❑ C.O.D. 4. Restricted Delivery? (Extra Fee) ❑ Yes 2. Article Number (transfer from service label) 11019 .3400 0011 0(0 3q 4 aj j PS Form 3811, March 2001 Domestic Return Receipt 102595-01-M-1424 r r r mPostage 0 Certified Fee Return Receipt Fee (Endorsement Required) O Restricted Delivery Fee Q (Endorsement Required) C3 0 Total Postage & Fees e (Pl e Print C/earP m E-. E- o--a�bar Street, Apt. No . or PO Bc # $ P �cr O City State, ZlP+4 Iti \1 4 UNITED STATES POSTAL SERVICE First -CI S "Permit No. • Sender: Please print yonam�,�address, and ZIP+4yin thisbox i PNOWS i i p. C. -�)o,C 15!�to`4 C l '� RC 5to f J .�W � a8 i it,I,ll,,1„I,Ir,Ilrtttrll,lrlltili,rlifill ,r111ifill IIII fil,l ■ Cernplete items 1, 2, and 3. Also complete item 4 if Restricted Delivery is desired. ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card to the batik of the mailpiece, or on the front if space permits... 1. Article Addressed to: - ' i LUI A ar�a re+ E 1, o 4o Cedar R, dgc __br► de. ,,,Heft lir�- , ( c. ag40s A. Received by (Please Print Clearly) B. Date of Delivery C. Signature c. 1 X "0 Agent ❑ Addressee D. Is delivery 9ddress dill rent from item 1? IFI-� If YES, enter delivery address below: ❑ No :Arq IJC- 3. _Service Type LI Certified Mail ❑ EXDress Mail �LJ II IJUICU IVIGIII LJ V. V.v. 4. Restricted Delivery? (Extra Fee) ❑ Yes 2. Article Number 1 Q (transfer from service label) 109 . a o i� p C)1 j b l0 3 q /• .i Q o PS Form 3811, March 2001 Domestic Return Receipt 102595-01-M-1424 o Article y Aar OL ;rd Ir m Postage $ /, 3 .0 C3 Certified Fee b C� � ? � Return Receipt Fee (Endorsement Required) Restricted Delivery Fee Pos rk Here co (L.W-4 . � � �O Q (Endorsement Required) O M Total Postage & Fees o ? M m Name (lease Print Clearly) 4to be Co�m.P / ed by m ilerJ �ii f Q r et f 0-- o -- Street, Apt. No. • rP0 Box No. -----°�Q--- - C_ 1= 1 e. ------"-" """""-"-""'"-'-'-'---- �� Ciry. State, ZfP+4 -. ' W ' rn: ion, N, C . .2% 40S I RELEASE FOR PERMITS JKA 8/8/01 j< 2 RELEASE FOR CONSTRUCTION JKA 9/3/01 DESCRIPTION BY DATE Revisions Cityor~\ IMPROVEMENTS i ." pt" —STO—PL%,MWATER ` TOWN OP 1tIVER B 1 A!- Pmm'/ TOWN OF RIV u L � � vwL 41, ew CRAVEN COUNTY, NORTH CAROLINA HAZARD MITIGATION GRANT PROJECT HMGP-1134-0056 PHASEII VICINITY MAP NOT TO SCALE OWNER: TOWN OF RIVER BEND 45 SHORELINE DRIVE RIVER BEND, NORTH CAROLINA (252)638-3870 SPONSORING AGENCY: DEPARTMENT OF CRIME &c PUBLIC SAFETY DIVISION OF EMERGENCY MANAGEMENT DISASTER RECOVERY OPERATION") CENTER 1830—B TILLERY PLACE RALEIGH, NORTH CAROLINA 27604 ENGINEER: AVOLIS ENGINEERING, P.A. PO BOX 15564 NEW BERN, NORTH (252)633-0068 DRAWING INDEX SHEET TITLE CS COVER SHEET C1 OVERALL SITE PLAN CAROLINA 28561 C2 SITE PLAN & PROFILE - CROSSING #1 @ SHORELINE DRIVE C3 ENLARGED SITE PLAN & PROFILE - CROSSING #1 @ SHORELINE DRIVE C4 ENLARGED SITE PLAN & PROFILE - CROSSING @ LOCHBRIDGE DRIVE C5 ENLARGED SITE PLAN & PROFILE - CROSSING @ LAKEMERE DRIVE C6 ENLARGED SITE PLAN & PROFILE - CROSSING #2 (@ SHORELINE DRIVE C7 ENLARGED SITE PLAN & PROFILE - CROSSING @ OLD BRICK ROAD C8 IMPROVEMENTS @ MASTERS COURT AREA C9 DETAILS C10 DETAILS C11 DETAILS C12 DETAILS �LnLo ., (0,C) co � I � U � cy)Z cx W z in w_Ld °w� w �m X Ew ►� o z 00 (.D ��Q0o w�l w in c o ~ > N O U al w 0 01042CS.DWG A CROSSING #2 ® SHORELINE DRIVE Cl I C6 A Cl 105 A OVERALL SITE PLAN C1 C1 SCALE: 1"=200' PO �O ,ANCE o� Ai CROSSING ® OLD BRICK ROAD A C1 C7 POND IMPROVEMENTS ® MASTERS COURT A C1 [C8 �s \ 01 CROSSING ® LAKEMERE DRIVE r MARGO COURT to A CROSSING C LOCHBRIDGE DRIVE C1 C4 R1D(E DR1VE EXISTING DREDGE SPOIL AREA/ CONTRACTOR DISPOSAL AREA SEE NOTE 1 THIS SHEET CONTRACTOR LAYDOWN AREA SEE NOTE 2 THIS SHEET Kk- o� TOWN HALL CONSTRUCTION SEQUENCE THE CONTRACTOR SHALL COMPLETE THE CONSTRUCTION IN THE FOLLOWING ORDER TO ENSURE THE PROPER PERFORMANCE OF THE DRAINAGE STRUCTURES DURING CONSTRUCTION: STEP NO. 1 : CROSSING #1 @ SHORELINE DRIVE 2 : CROSSING @ LOCHBRIDGE DRIVE 3 : CROSSING @ LAKEMERE DRIVE 4 : CROSSING #2 @SHORELINE DRIVE 5 : CROSSING @OLD BRICK ROAD Q 6 : IMPROVEMENTS @MASTERS COURT � NOTE: 1. THE CONTRACTOR SHALL BE ALLOWED TO DISPOSE OF EXCESS SOIL MATERIAL FROM GRADING OPERATIONS IN THE EXISTING DREDGE SPOIL DISPOSAL AREA. THE CONTRACTOR SHALL SPREAD AND GRADE ALL MATERIAL PLACED IN THIS AREA TO ENSURE THE SURFACE DRAINAGE PATTERNS ARE MAINTAINED. ALL DISTURBED AREAS SHALL BE SEEDED IN ACCORDANCE WITH THE PROJECT VEGETATION PLAN. NO MATERIALS OTHER THAN SOIL SHALL BE DISPOSED OF IN THIS AREA, ALL OTHER MATERIALS GENERATED FROM THE CONTRACTORS OPERATIONS SHALL BE DISPOSED OF OFF SITE IN AN APPROVED DISPOSAL AREA. 2. THE CONTRACTOR SHALL BE ALLOWED A LAY DOWN AREA APPROXIMATELY 200'X200' IN THE GENERAL VICINITY OF THE TOWN OF RIVER BEND WATER RESOURCES OFFICE. THE CONTRACTOR SHALL BE RESPONSIBLE TO RETURN THE LAY DOWN AREA TO ITS ORIGINAL CONDITION FOLLOWING CONSTRUCTION. THE FINAL LOCATION OF THE LAY DOWN AREA SHALL BE ESTABLISHED BY THE TOWN OF RIVER BEND. 1 2 RELEASE FOR PERMITS JKA 08/08/01 RELEASE FOR CONSTRUCTION JKA 09/03/01 NO, DESCRIPTION BY I DATE Revisions PN� N10A �R�vE CROSSING 1 ® SHORELINE DRIVE A p� Cl C2 yYkK< ALL WORK THIS AREA IS BID ALTERNATE NO. 1 ` GRAPHIC SCALE 200 0 100 200 400 ALL WORK T HIS AREA IS BID ALTERNATE NO. 2 ( IN FEET ) I inch = 200 ft. 400 CA��ui�iii Q�H..Off'''%,,, ` FESS•••29�'y9`` EAL 15738 oQ O O Z >1 E, wr Z�4 (D E- C LO' 00c0 Z CD N W zN Ln O W N W �m N X Ez� 'moo W�p C U� _(D o I� 'a m CV O U O `4 z F-4 O W Q � � O w W H Z j � w O Z Z O O O w 01042.DWG W 1 RELEASE FOR PERMITS JKA ABBREVIATIONS 2 RELEASE FOR CONSTRUCTION JKA CB CATCH BASIN HARBOUR TOWN MARINA NO, ,�` ./ ,•'' ,t' ,� ,' CENTERLINE F CONC. CONCRETE CMP CORRUGATED METAL PIPE EOP EDGE OF PAVEMENT ELEV ELEVATION INV INVERT0 10 ► OHE OVERHEAD ELECTRIC I R RADIUS RCP REINFORCED CONCRETE PIPE R /W RIGHT-OF-WAY j TBM ELEV=6.1 STA STATION ► TBM TEMPORARY BENCHMARK INVERT 15 RCP ► o � s ` cp ` a � V A SITE PLAN - CROSSING #1 ® SHORELINE DRIVE C1 C2 SCALE: 1"=20' 16 14 12 10 2 CD _- CD i� i - - s i r f / 200 ..s= , .. 8 l,i 3 E V OR\ I � TOWN HALL LAKE VEGETATION REQUIREMENTS: 1. ALL EXISTING SURFACES COVERED WITH A FULL STAND OF GRASS SHALL BE REVEGEATED WITH CENTEPEDE SOD. 2. ALL NATURAL AREAS GRADED OR OTHERWISE DISTURBED SHALL BE SEEDED AND MULCHED. 3. THE CONTRACTOR SHALL COMPLETE A PHYSICAL INSPECTION WITH THE PROJECT ENGINEER PRIOR TO STARTING CONSTRUCTION AT ANY SITE TO DOCUMENT EXISTING CONDITIONS. AVEMENT &.,CULVERT' TC TOP OF CONCRETE ► TYP TYPICAL QD '11y_ ENLARGED SITE PLAN - CROSSING #1 A ® SHORELINE DRIVE C2 C3 r r r r r r r LEGEND 1 EXISTING NEW EXISTING NEW +�3a.007 SPOT ELEVATION +38.W CONCRETE 0 r --o WATER SERVICE ASPHALT 0 ------- WATER MAIN M TEMPORARY BENCHMARK ---s------ SEWER MAIN s ===> DRAINAGE FLOW 1 DRAINAGE PIPE L..I CATCH BASIN � ----on -- - DRAINAGE DITCH - UNDERGROUND ELECTRIC OVERHEAD ELECTRIC _----.- GAS SERVICE ---- -- - CONTOUR x VALVE ' HYDRANT ( SEWER MANHOLE QS ICI CURB INLET M ELECTRIC TRANSFORMER UTILITY POLE STREET LIGHT 1, TREE TREE LINE DRY HYDRANT -- SIGN 200.CO' VC rr (D >_ Oo PVI ELEV = 10.00 o N + � CD CD U> C--)U Q O Qo r- z Ww FIN SH GRAD ® SHORELINE DRIVE EXISTING GRADE SHOF ELINE DR VE -� - _E LLLVM ROAD SECTION r O 00 Or)00CD 0� 0 O Q0 (.(DO� O 00 � O 00 N O 00 CD .0-) O 00 �? 0� 00 pNj cr; 00 000 (7� 00 0000 00 07 00 N Cr a7 C7� 3+OOL 2+OOL rB__��PROFILE - CROSSING #1 ® SHORELINE DRIVE C2 C2 HORIZONTAL: 1"=20' VERTICAL: 1"=2' 1 + OOL 0+00 1 +OOR 2+OOR 3+OOR 16 14 12 10 E:3 6 4 2 4+OOR GENERAL CONSTRUCTION NOTES: 8/8/01 9 /3 /01 DESCRIPTI❑N BY DATE Revisions 1. THE LOCATIONS SHOWN OF UNDERGROUND AND ABOVE -GROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE ALL UTILITIES IN THE AREA OF WORK AND TO PROTECT THEM DURING THE COURSE OF CONSTRUCTION. 2. THE CONTRACTOR SHALL MAINTAIN AT LEAST ONE-WAY TRAFFIC MOVEMENT IN ALL AREAS OF WORK AT ALL TIMES. THE CONTRACTOR IS RESPONSIBLE FOR THE CONSTRUCTION OF TEMPORARY BYPASSES TO ENSURE THIS TRAFFIC MOVEMENT. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING SAFETY SIGNAGE, TRAFFIC SIGNAGE, LIGHTED BARRICADES, FLAG MEN, AND ANY OTHER MEASURE DEEMED NECESSARY TO ENSURE THE SAFE AND EFFICIENT MOVEMENT OF TRAFFIC IN THE AREAS OF CONSTRUCTION. 4. EROSION AND SEDIMENTATION CONTROL DEVICES SHALL BE REMOVED ONLY AFTER A SATISFACTORY VEGETATIVE COVER HAS BEEN ESTABLISHED AND UPON APPROVAL OF THE PROJECT ENGINEER. SPECIFIC WORK ITEMS: 1. COMPLETE ALL PAVEMENT OVERLAY IN ACCORDANCE WITH DETAIL C, SHEET C11. 2. COMPLETE ALL PAVEMENT REPAIRS IN ACCORDANCE WITH DETAIL C, SHEET C11. 3. COMPLETE ALL PAVEMENT STRIPING IN ACCORDANCE WITH DETAIL D, SHEET C11. NEW STRIPING SHALL MATCH EXISTING STRIPING. 4. PROVIDE PIPE TRENCHING/BACKFILLING IN ACCORDANCE WITH DETAIL E, SHEET C11. 5. COMPLETE ALL REVEGETATION IN ACCORDANCE WITH DETAIL D, SHEET C12. 6. THE CONTPACTOR SHALL REMOVE ALL EXISTING SEDIMENT AND VEGETATION IN THE INLET AND OUTLET AREAS TO RECEIVE RIP -RAP APRONS. REMOVE ALL VEGETATION < 4" CALIPER IN SIZE TO A POINT FLUSH WITH THE NATURAL GROUND LEVEL WITHOUT DISTURBING THE ROOT SYSTEM. PLACE FILTER FABRIC AND RIP -RAP. SPECIFIC WORK ITEMS: DEMOLITION 1. REMOVE EXISTING PAVEMENT TO THE EXTENT SHOWN. 2. EXCAVATE AND REMOVE EXISTING STORM DRAIN PIPE. 3. REMOVE EXISTING BULKHEAD TO THE EXTENT SHOWN. NEW WORK 1. INSTALL NEW STORM DRAIN PIPE AS INDICATED. 2. REPAIR/REBUILD ROAD SECTION AS INDICATED. 3. GRADE NEW OUTLET SWALES AS INDICATED. 4. CONSTRUCT NEW BULKHEAD AS INDICATED. 5. RE-ESTABLISH VEGETATION IN ALL DISTURBED AREAS. 6. ELEVATE ROAD SECTION AS INDICATED. 7. RESTRIPE NEW ROADWAY SURFACE TO MATCH EXISTING SURFACE GRAPHIC SCALE 20 0 10 20 40 80 CD Q of o z �' ��MMpQ� E, N I H W W .. O dj w p> Ln O C00Ln ., •� N c� a) I Q) U� C o, z' w z� W ow� Co,----, W a �x Q ,_.., c wz o C0 7 > C (00 � W LL► L0 o -0 � r) C x� oLn O U oN m� Q F-+ Q i W W Q o Ww O W O I 0 0 O rx &--, a O W > z � a � W H U� ( IN FEET ) 1 inch = 20 ft. 01042C2.DWG o 200.00' VC N + PMSTA = -0+00 + ' T PVI ELEV = 10.00 vi � A.D. = 0.32 >m K=630.21 ww 12 12 10 4 2 0 -2 cc cc LIMIT OF PAVEMENT/STONE BASE_- FINISH GRACE ® �_ SHORELINE DRIVE REMOVAL/RE D LACEMENT EXI TING GRADE ® HORELINE DRIVE ELEVATE ROAD SECTION UTILIZING TYPE H BINDER A DRAINAGE PIPE -TYPE A _ ROUTE EXISTNG UTILIZING DU 8" PVC WATER TILE IRON PIPE. P MAIN BELOW NEW OVIDE 24" MINIMU SEPARATION. p 00 N U� p 00 00 p d O 00 Co Ln aj 00 1+OOL 0+50L 0+00 0+50R 1 m 4 ;ULVERTS I VERTICAL 0 _2 • 1 +OOR VEGETATION REQUIREMENTS: 1. ALL EXISTING SURFACES COVERED WITH A FULL STAND OF GRASS SHALL BE REVEGEATED WITH CENTEPEDE SOD. 2. ALL NATURAL AREAS GRADED OR OTHERWISE DISTURBED SHALL BE SEEDED AND MULCHED. 3. THE CONTRACTOR SHALL COMPLETE A PHYSICAL INSPECTION WITH THE PROJECT ENGINEER PRIOR TO STARTING CONSTRUCTION AT ANY SITE TO DOCUMENT EXISTING CONDITIONS. ABBREVIA'DONS CATCH BASIN CB CENTERLINE CONC. CONCRETE CMP CORRUGATED METAL PIPE DBL DOUBLE EOP EDGE OF PAVEMENT ELEV ELEVATION HW HARDWOOD TREE INV INVERT OHE OVERHEAD ELECTRIC R RADIUS RCP REINFORCED CONCRETE PIPE R/W RIGHT-OF-WAY SCH SCHEDULE SS STAINLESS STEEL STA STATION TBM TEMPORARY BENCHMARK TC TOP OF CONCRETE TYP TYPICAL LEGEND EXISTING NEW +(38.00') SPOT ELEVATION -- C- WATER SERVICE _-- w-----, WATER MAIN w -- --- -- SEWER MAIN s - --n-- - DRAINAGE PIPE ----- - -- DRAINAGE DITCH UNDERGROUND ELECTRIC -- 0+e--- - OVERHEAD ELECTRIC --e---- - GAS SERVICE -- 5------ CONTOUR 5 ---ro--- - FIBER OPTIC Cw� VALVE HYDRANT S SEWER MANHOLE �S Wil CURB INLET CONCRETE ASPHALT TEMPORARY BENCHMARK DRAINAGE FLOW C� CATCH BASIN ❑ Fl ELECTRIC TRANSFORMER UTILITY POLE ,t STREET LIGHT TREE ._..._-._-_.� TREE LINE - DRY HYDRANT SIGN GENERAL CONSTRUCTION NOTES: 1. THE LOCATIONS SHOWN OF UNDERGROUND AND ABOVE -GROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE ALL UTILITIES IN THE AREA OF WORK AND TO PROTECT THEM DURING THE COURSE OF CONSTRUCTION. 2. THE CONTRACTOR SHALL MAINTAIN AT LEAST ONE-WAY TRAFFIC MOVEMENT IN ALL AREAS OF WORK AT ALL TIMES. THE CONTRACTOR IS RESPONSIBLE FOR THE CONSTRUCTION OF TEMPORARY BYPASSES TO ENSURE THIS TRAFFIC MOVEMENT. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING SAFETY SIGNAGE, TRAFFIC SIGNAGE, LIGHTED BARRICADES, FLAG MEN, AND ANY OTHER MEASURE DEEMED NECESSARY TO ENSURE THE SAFE AND EFFICIENT MOVEMENT OF TRAFFIC IN THE AREAS OF CONSTRUCTION. 4. EROSION AND SEDIMENTATION CONTROL DEVICES SHALL BE REMOVED ONLY AFTER A SATISFACTORY VEGETATIVE COVER HAS BEEN ESTABLISHED AND UPON APPROVAL OF THE PROJECT ENGINEER. SPECIFIC WORK ITEMS: 1. COMPLETE ALL PAVEMENT OVERLAY IN ACCORDANCE WITH DETAIL C, SHEET C11. 2. COMPLETE ALL PAVEMENT REPAIRS IN ACCORDANCE WITH DETAIL C, SHEET C11. 3. COMPLETE ALL PAVEMENT STRIPING IN ACCORDANCE WITH DETAIL D, SHEET C11. NEW STRIPING SHALL MATCH EXISTING STRIPING. 4. PROVIDE PIPE TRENCHING/BACKFILLING IN ACCORDANCE WITH DETAIL E, SHEET C11. 5. COMPLETE ALL REVEGETATION IN ACCORDANCE WITH DETAIL D, SHEET C12, 6. THE CONTRACTOR SHALL REMOVE ALL EXISTING SEDIMENT AND VEGETATION IN THE INLET AND OUTLET AREAS TO RECEIVE RIP -RAP APRONS. REMOVE ALL VEGETATION < 4" CALIPER IN SIZE TO A POINT FLUSH WITH THE NATURAL GROUND LEVEL WITHOUT DISTURBING THE ROOT SYSTEM. PLACE FILTER FABRIC AND RIP -RAP. SPECIFIC WORK ITEMS - DEMOLITION 1. REMOVE EXISTING PAVEMENT TO THE EXTENT SHOWN. 2. EXCAVATE AND REMOVE EXISTING STORM DRAIN PIPE. 3. REMOVE EXISTING BULKHEAD TO THE EXTENT SHOWN. NEW WORK 1. INSTALL NEW STORM DRAIN PIPE AS INDICATED. 2. REPAIR/REBUILD ROAD SECTION AS INDICATED. 3. GRADE NEW OUTLE F SWALES AS INDICATED. 4. CONSTRUCT NEW BULKHEAD AS INDICATED. 5. RE-ESTABLISH VEGETATION IN ALL DISTURBED AREAS. 6. ELEVATE ROAD SECTION AS INDICATED. 7. REROUTE WATER MAIN AS INDICATED. 8. RESTRIPE NEW ROADWAY SURFACE TO MATCH EXISTING SURFACE GRAPHIC SCALE 10 0 5 10 20 40 C\2 O Q O E- (D U W (D p� 0 Lo c 00 � I w zU) ry W w N m W �x w� E C z o 00 0 C QO �o W w o �ro c xn ° o� M--1 m N ►-� U ON Q a- Ca � z W U� ►-� o x W Q W w z C0 w O O E-4 O o El z O W a H U) w z W B PROFILE - CROSSING #1 ® SHORELINE DRIVE CAC3 HORIZONTAL: 1"=20' VERTICAL: 1"=2' ( IN FEET ) 1 inch = 10 ft. 01042C2.DWG TOP OF WALL = G PIPE = E INVERT OUT = B LENGTH = C a N A LENGTH = C RETAINII SECTI NOTE: PROVIDE PIPE BEDDING AND TRENCH WORK IN ACCORDANCE WITH DETAIL E, SHEET C11 - � PIPE PIPE GROUP 0 PIPE TOP OF WALL = F INVERT IN = A DIMENSION SUMMARY LOCATION AFT B FT C FT D FT E IN X IN F FT) G FT CROSSING #1 ® SHORELINE DRIVE 1.3, 0.10' 62' 7' 2 112" X 75" 1 VARIES I VARIES A DRAINAGE PIPE -TYPE A C3 C9 NOT TO SCALE vnnirc (rr- ni AAI RIP RAP THICKNESS = K FILTER FABRIC FLARED -END SECTION - E RIP RAP APRON PLAN FLO =C _ VARIES -SEE PLAN _ RIP RAP THICKNESS = G FILTER FABRIC FLARED -END SECTION = E RIP RAP APRON SECTION DIMENSION SUMMARY LOCATION AFT B FT C FT DIN X IN E IN X IN F FT GIN CROSSING 0 LAKEMERE DRIVE 8.4, 7.7' 110' 2 81" X59" 81" X 59" 9.4' 18" CROSSING #2 ® SHORELINE DRIVE 10.3' 8.6' 73' 2 57" X 38" 57" X 38" 11.3' 18" CROSSING C OLD BRICK ROAD 13.0' 12.7' 40' 2 48" RCP 48" RCP 14.0' 18" (_­CDRAINAGE PIPE -TYPE C WCC' NOT TO SCALE C6 C7 ri AMrn ru— I QID DAID Tul('VKlCCC — V DIMENSION SUMMARY LOCATION A FT) DIN X IN E IN X IN F FT G FT H FT I FT J(FT) KIN CROSSING C LOCHBRIDGE DRIVE 2.5' 2.1' 136' 2 81" X 59" 81" X 59" 6.5' 3.8' 4.8' 50't 30' 18" ('_BDRAINAGE PIPE -TYPE B ��C NOT TO SCALE APRON NOTE: PROVIDE PIPE BEDDING AND TRENCH WORK IN ACCORDANCE WITH DETAIL E, SHEET C11 ' RAP OVERFLOW WEIR = H NORMAL WATER LEVEL = G � PIPE GROUP I \A CAllf'p(iiii FEss�� /ti;, AL 15738 v0 0 012 oQ �W oE-4 O O � � E-, Q �(.0 o c `n Ln �N� � I a) U WzLo W _ C) wLJ N W �m Ew � 0 00 � >o c CO o W wL U� a o (.C) ~ > m N OUoN V1 F-I o w Q� Ww o W o� O cn O W C9 0 1042. DWG (2) NEW 112" X 75" CORRUGATED METAL ARCH..PIPES TIE -BACK ANCHOR TYPICAL 1 OF 10 _..�._.- BULKHEAD C12 C12 8 P`1 N F P� Y EX\S�N� P X ��N ENS 6 5 4 ____ X ;PENLARGED PLAN VIEW -INLET AREA OSSING, #1 @ SHORELINE DRIVE SCALE: 1 =5 L ELE.-7.6 , i INV.=0.10 NEW INV. \ 0.10' (EXISTING) J 1O� 1 �f , t � J f � ' oP &. 1 p1PE SR 1 1 (, MEND EXISTING BULKHEAD TO BE REMOVED j (!l TO EXTENT OF NEW BULKHEAD AFTER ,1 INSTALLATION OF NEW BULKHEAD IS COMPLETE w f/� TOWN HALE LAKE X ELE.=7.6' 6 5 _ — X = 5.6' ATTACH EXISTING WOODEN BULKHEAD TO NEW BULKHEAD NOTE: EXCAVATE UPLAND AREA BETWEEN NEW AND EXISTING BULKHEADS TO ELEVATION -4.0'. NOTE: ATTACH EXISTING EXCAVATE UPLAND AREA BETWEEN NEW AND HARBOUR TOWN MARINA WOODEN BULKHEAD\ EXISTING BULKHEADS TO ELEVATION -4.0'. TO NEW BULKHEAD ATTACH EXISTING C BULKHEAD ELE.5.6' WOODEN BULKHEAD C12 C12 ' TO NEW BULKHEAD TIE -BACK ANCHOR r CUT EXISTING 15 TYPICAL OF 1 OF 12 POLYETHYLENE PIPE OFF FLUSH WITH FACE OF NEW BULKHEAD. INV=1.9't EXISTING BULKHEAD TO BE REMOVED TO EXTENT OF NEW BULKHEAD AFTER X .' . INSTALLATION OF NEW BULKHEAD IS '\...COMPLETE y 1 5 — ELE.=7.6 X X 75" CORRUGATED ETAL ARCH PIPES x B ENLARGED PLAN VIEW -OUTLET AREA C3 C12 CROSSING #1 @ SHORELINE DRIVE SCALE: 1"=5' WIDTH AS REQUIRED NEW CONCRETE 4' MINIMUM MIN CUT, REMOVE, AND REPLACE CONCRETE FLUME TO MATCH EXISTING. REMOVE AS NECESSARY TO �W-STALL NEW BULKHEAD X F(CiM� - 6 X ELE.=7.6' X INV.=0.10' (NEW) INV.=0.10' (EXISTING) EXISTING CONCRETE SAWCUT 6x6 10/10 WWF COMPACTED SUBGRADE NOTES: 1. REMOVE CONCRETE AREAS AT JOINTS WHEN JOINTS ARE LOCATED WITHIN 5 FEET OF AREA OF WORK. 2. CONCRETE FINISH & JOINT PATTERN SHALL MATCH EXISTING 3. ALL SAWCUTS SHALL BE PERPENDICULAR TO THE EDGE OF THE EXISTING CONCRETE. / F TYPICAL CONCRETE REPAIR C8 C12 NOT TO SCALE 1 RELEASE FOR PERMITS JKA 8/8/0 10' MIN. CENTER TO CENTER 2 RELEASE FOR CONSTRUCTION JKA 9/3/0 NO. DESCRIPTION BY DATE TOP OF WALL ELEVATION = VARIES SEE PLAN REVISIONS \f` 1 V \�/ ' ``i `\,,,' \� `\�` (6) #5 CONTINUOUS TOP OF WALL X. `f' CONCRETE SHEET PILE ELEVATION VARIES 3" CLEAR COVER PILE BUTT ELEVATION CAP —� �\ �� (SEE PLAN) xx f;�', `,; /\\/ # STIRRUP 4,12 0C� o ' /``, VINYL `\ SHEET PILE \ c 4 y :\.� / \ \\; I 3/4" GALVANIZED TIE -BACK \ \/ ` RODPROVIDE 9 HOOK e ; 17 NORMAL WATER ELEVATION = 0.00' \ '`/r'\i VINYL SHEET PILE \ \ , SECTION @ CONCRETE CAP \\\ ELEVATION OF BOTTOM = -4.0' TIMBER TIE -BACK PILE NOTE PLACE TIMBER TIE -BACK PILES AT THE LOCATIONS INDICATED ON THE PLAN VIEW AS " X "' u TIP SHEET PILE ELEVATION = -12 .0' TIP TIMBER PILE ELEVATION = -12.0' C BULKHEAD C12 C12 NOT TO SCALE A. SEEDING AND MULCH ALL AREAS INDICATED TO BE SEEDED AND MULCHED SHALL BE SEEDED TO THE FOLLOWING SPECIFICATIONS: SEED BED LIME 1 TON ACRE FERTILIZER Y2 TON/ACRE SEED SEPTEMBER - APRIL RYE GRAIN 50 LBS/ACRE TALL FESCUE 50 LBS/ACRE MAY -AUGUST COMMON BERMUDA 40 LBS/ACRE STRAW MULCH WILL BE APPLIED AT A RATE WHICH WILL INSURE APPROXIMATELY 75% COVERAGE OF THE SEEDED AREA. THE STRAW AND SOWN SEED WILL BE LIGHTLY DISCED INTO THE BED TO FURTHER RESIST IT FROM BLOWING OR WASHING. THE CONTRACTOR SHALL GUARANTEE A FULL STAND OF GRASS OVER THE ENTIRE DISTURBED AREA. IF NECESSARY, THE CONTRACTOR WILL WET DOWN THE AREAS TO ASSIST IN SEED GERMINATION OR AID IN GROWTH IN TIMES OF EXCESSIVELY DRY WEATHER. A STAND OF GRASS WILL BE CONSIDERED ACCEPTABLE WHEN THE ENTIRE STAND IS AT LEAST FOUR INCHES HIGH AND HAS ACHIEVED AT LEAST 95% COVERAGE OF DISTURBED AREAS. RESEEDING WILL BE REQUIRED AS NECESSARY BY THE CONTRACTOR TO OBTAIN THE SPECIFIED STAND OF GRASS. B. SOD ALL AREAS TO BE SODDED SHALL BE SODDED TO THE FOLLOWING SPECIFICATION: SOD SHALL BE NURSERY CUT CENTIPEDE CONFORMING TO NCDOT STANDARD SPECIFICATIONS FOR ROADWAYS AND STRUCTURES, SECTION 1060-6. SOD SHALL BE INSTALLED WHEN 48 HOURS AFTER IT IS CUT FROM THE NURSERY. D VEGETATION PLAN C8 C12 NOT TO SCALE C2-C8 MANHOLE FRAME & COVER SEE NOTE 4 BELOW GRADE RINGS AS REQUIRED ECCENTRIC CONE ---- SECTION 0-RING JOINT (TYP)- 5" MIN. THICK WALL - RISER SECTION TAPERED LIFTING HOLE -GROUT FULL UPON INSTALLATION REINFORCEMENT SEE NOTE 1 - CAST -IN -PLACE MANHOLE STEPS - BASE SECTION - PILE BUTT ELEVATION r. 4" SQUARE PLATE WASHER 3/4" GALVANIZED TIE -BACK ROD. PROVIDE 9" HOOK 3/4" NUTS NOTCH PILE 3/4" MAX. TIMBER TIE -BACK PILE TO SEAT WASHER FLAT II CONNECTION @ TIE -BACK PILE RIM AS INDICATED 2' 0 4' UNLESS OTHERWISL INUIUA REMOVE TOP HALF OF EXISTING SEWER PIPE IN MANHOLE UPON COMPLETION OF MANHOLE. ) INVERT IN AS INDICATED SHAPED GROUT INVERT ' " SEWER MAIN SIZE AS INDICATED ANCHOR BRACKETS ° PER MANUFACTURER a " `' INVERT OUT AS INDICATED rLh REQUIREMENTS !fir „ 12 MIN ALL SIDES 8 MIN. < MIN. � �..� �- •��. 3" GROUT ; #4 @ 12" O.C. E.W. 6 MIN. GRAVEL BASE CAST -IN -PLACE CONCRETE BASE LEVEL COMPACTED SUBGRADE NOTES: SEE NOTE 3 1. FOR MANHOLE LESS THAN 10' DEEP, A PRECAST CONCRETE BASE PLACED MONOLITHICALLY WITH THE MANHOLE BASE SECTION CAN BE USED. MINIMUM PRECAST BASE THICKNESS SHALL BE 6". 2. IF UNSUITABLE SUBGRADE MATERIAL IS ENCOUNTERED, NOTIFY THE PROJECT ENGINEER FOR RESOLUTION. E BUILT -OVER MANHO'_E C4 C12 NOT TO SCALE H o c `o 00 Ln C] � I U co wz� W _� owe W �m x Ew cz o 00 >,jo c: w� I c � ~ > m N O� a- N Crn 1 I� E-IIi O Q� W W W (a4 W O E� E-i � �O O o E-4 w � U 01042. DWG