Loading...
HomeMy WebLinkAboutAQ_F_0900009_20210216_ST_RvwMemo (5) Division of Air Quality February 16, 2021 MEMORANDUM To: Heather Carter, Fayetteville Regional Supervisor From: Gary L. Saunders, Stationary Source Compliance Branch ,f Subject: The Chemours Company—Fayetteville Works Fayetteville, Bladen County, North Carolina Facility ID. No.0900009, Permit No. 03735T47 Performance Testing for HFPO Dimer Acid Conducted on December 11, 2020 at Vinyl Ethers South (VES) Carbon Bed by O'Brien &Gere, Inc. Tracking No. 2020-318ST Summary of HFPO Dimer Acid Test Program Sources Tested The VES carbon bed adsorber was sampled on December 11, 2020. The carbon bed adsorber was returned service for controlling fugitive emissions from "room air" at the VES production area after the thermal oxidizer became operational. Testing was conducted to determine removal efficiency and emission rates from the VES fugitive emissions and controls. Sampling Method Testing was conducted using a modified EPA Method 0010 found in the SW-846 compendium of Test Methods for Evaluating Solid Waste:Physical/Chemical Methods. This sampling train is a variation of the EPA Reference Method 5 found in 40 CFR 60,Appendix A. The Method 0010 train extracts a sample isokinetically from the gas stream, passes the sample through a temperature-controlled filter,through a temperature-controlled condenser and into a series of XAD-2 resin "traps" and impingers to capture and collect the materials that passed through the filter. The test method is designed to capture certain particulate and condensable materials for later recovery and analysis. After sample recovery,the samples were sent to Chemours' contractor,Test America's laboratory in Denver, Colorado. HFPO Dimer Acid was extracted from the resin traps. This summary of results only addresses the results provided by Eurofins (Test America)for Chemours. Laboratory analysis and quantification was performed using a liquid chromatography column and a dual mass spectrometer (LC/MS/MS). Test Results The reported HFPO Dimer Acid test results reflect corrected emission rates accounting for dilution and spike recovery values. Vinyl Ethers South Area Test Results Inlet and outlet emissions from the VES carbon bed adsorber were measured on December 11, 2020 to determine the removal efficiency of HIPPO Dimer Acid from the process room air emissions. Each test run was nominally 96 minutes in length. The process was operating normally and was producing PMVE and PEVE. No issues were noted in the sample recovery and analytical data. Table 1. Summary of Stack Test Results for VES Carbon Bed on December 11,2020 HFPO Dimer Acid Emission Rate Run Number Inlet Outlet %Removal Efficiency (lb/hr) (lb/hr) 1 1.91E-03 1.65E-04 91.36 2 1.69E-03 1..81E-04 89.29 3 1.41E-03 1.22E-04 91.35 Average 1.67E-03 1.56E-04 90.66 Summary and Conclusions NC DAQ was not on-site to observe this test due to COVID-19 safety concerns. NC DAQ concludes that the testing was conducted in accordance to the modified testing protocol submitted by Chemours and that the analytical results appear representative of the stack conditions and process operations during the testing except as noted above. Cc: CentralFiles—BladenCounty [BEAM Documents-0900009