Loading...
HomeMy WebLinkAboutAQ_F_1400068_20190319_ST_RvwLtr ROY COOPER `— Govemar MICHAEL S.REGAN Secretary I MICHAEL A.ABRACZINSKAS NORTH CAROLINA Director Environmental Quality I March 19, 2019 i Mr. Scott Greene, President Quality Hardwoods, LLC P. O. Box 2705 North Wilkesboro,NC 28659 SUBJECT: Stack Test Report Quality Hardwoods, LLC Lenoir,North Carolina Caldwell County Air Permit Number 02765RI2 Facility ID: 01/14/00068 Fee Class: Small Tracking No.: 2018-270st Dear Mr. Greene: The Division of Air Quality has reviewed and deemed acceptable the results from the EPA Method 5/202 tests for the total particulate matter (PM) from wood-fired boiler ES-2. Environmental Source Samplers, Inc. (ESS) performed these tests on October 16, 2018. These tests satisfy the testing requirements as stated in the subject permit. If you have any questions regarding this matter,please do not hesitate to contact me at (828) 296-4500. Sincerely, S Richard Morris Environmental Specialist 4 i Enclosure: i f I North Carolina Department of Environmental Quality I Division of Air Quality Asheville Regional Office 1 2090 U.S.Highway 70 1 Swannanoa,NC 28778 ��A,� oop.�emmrryo-oom.oni vo.n�r 828.296.4500 T 1 828,299,7043 F DIVISION OF AIR QUALITY March 8,2019 MEMORANDUM To: Brendan Davey,P.E.,Asheville Regional Office i From: Shannon Vogel, Stationary Source Compliance Branch Subject: Quality Hardwoods,LLC Lenoir, Caldwell County,North Carolina Facility ID 1400068,Permit No. 02765R12 f Total Particulate Matter Emissions Testing of ES-2 Boiler Performed October 16,2018 by Environmental Source Samplers, Inc. (ESS) Tracking No. 2018-270st ESS performed EPA Method 5/202 to determine the total particulate matter(PM)from wood-fired boiler ES-2. The test results are acceptable to demonstrate compliance with the applicable emissions limits. The maximum per heat input rate for Boiler ES-2 is 13.9 million Btu per hour(mmBtu/hr). Emissions are controlled by multicyclone CD-2. 15A NCAC 2D .0504 Particulates From Wood Burning Indirect Heat Exchangers applies. Total PM emissions are limited to 0.46 pounds per million Btu(lb/mmBtu). The test results are tabulated below. 40 CFR 63 Subpart JJJJJJ National Emissions Standards for Hazardous Air Pollutants for Industrial Commercial and Institutional Boilers Area Sources also applies. Pollutant Test Results Emission Limit Standard Compliance Filterable PM 0.35 lb/mmBtu --- --- --- Condensible PM 0.08 lb/mmBtu --- --- Total PM 0.43 lb/mmBtu 0.46 lbhmnBtu 2D .0504 Yes Heat Input Rate 2.5 mmBtu/hr 13.9 mmBtu/hr Permitted Max The test results demonstrate compliance with 2D .0504. The test results are acceptable to demonstrate compliance for heat input rates up to approximately 3 mmBtu/hr. Additional testing may be required for firing at higher heat input rates. If you have any questions regarding the results of this review, please contact me at 919-707-8416 and shaiwon.vogel a ncdenr.gov. cc: Central Files, Caldwell County IBEAM Documents— 1400068 I