MICHAEL ABRACZINSKAS December 11,2018
Director
Mr. Alan Skrzypczak
Facility Manager
Stericycle, Inc.
Post Office Box 310
Haw River,North Carolina 27258-0310
SUBJECT: Review of 2018 CO/02 CEMS RATA
Stericycle, Inc.
Haw River, Alamance County,North Carolina
Facility ID No. 0100010
Air Permit No. 05896T25
Dear Mr. Skrzypczak:
Thank you for the timely submittal of the subject report dated,November 29, 2018, for the
carbon monoxide(CO)/oxygen(02) continuous emission monitoring systems (CEMS)
operating at Stericycle's Haw River facility. The Division of Air Quality(DAQ)has completed
its review of the relative accuracy test audit(RATA) and has the following comments:
1. The CO/02 analyzers monitoring incinerators ES01 and ES02 were installed pursuant to 15A
NCAC 02D .1206 -Hospital, Medical, and Infectious Waste Incinerators and Air Permit No.
05896, Specific Condition 2.1.A.2.t.
2. Testing was conducted by TRC Environmental Corp. (TRC) on October 31, 2018. Test
results from the RATA indicated the CO and 02 analyzers appear to have met the relative
accuracy requirements set forth in 40 CFR Part 60,Appendix B, Performance Specification 3
(PS-3) and PS-4A as summarized below.
Emission Source Parameter I Relative Accuracy Specification
CO
ES01 1.45%* <5% of standard*
02 2.38% <20% of reference method
ES02 CO 2.89%* < 5%of standard*
02 0.84% <20%of reference method
*Alternative demonstration:RA<5%when using emission standard.
ME
\`
Opwtiwal of B W mI W pl U W b�
North Carolina Department of Environmental Quality I Division of Air Quality
217 West Jones Street 11641 Mail Service Center I Raleigh,North Carolina 27699-1641
919.707.8400
Mr. Alan Skrzypczak
December 11, 2018
Page 2
3. A RATA was also performed on the backup CO CEMS (Mfg/model: Thermo Scientific/48i;
Serial#: CM 09080034). Test results indicate the backup analyzer met the requirements for
relative accuracy as set forth in PS-4A. Should the backup CEMS be pressed into service,
please refer to our letter of December 12, 2012, for conditions of its use.
4. 40 CFR Part 60,Appendix F requires that quarterly audits must be conducted,with a RATA
being conducted at least once every four calendar quarters. The next RATA for ESO1 and
ES02_should be completed by December 31, 2019. Please ensure that quality
assurance/quality control (QA/QC)requirements are met and complied with at all times. In
addition,please notify this office at least 45 days prior to performing the annual RATA so
that arrangements can be made to observe the test.
If you should have any questions,please contact me at(919) 707-8493 or alan.drake@ncdenr.gov.