No preview available
HomeMy WebLinkAboutAQ_F_1200099_20190109_CMPL_InspRpt (4) NORTH CAROLINA DIVISION OF Asheville Regional Office AIR QUALITY Kontane,Inc. NC Facility ID 1200099 Inspection Report County/FIPS: Burke/023 Date: 01/09/2019 Facility Data Permit Data Kontane,Inc. Permit 06457/R06 3876 Martin Fishpond Street Issued 2/14/2014 Hickory,NC 28602 Expires 1/31/2022 Lat:35d 42.4820m Long: 81d 26.3140m Class/Status Small SIC: 2441 /Nailed Wood Boxes And Shook Permit Status Active NAICS: 32192/Wood Container and Pallet Manufacturing Current Permit Application(s)None Contact Data Program Applicability Facility Contact Authorized Contact Technical Contact SIP Kenny Taylor Jason Essenberg Craig Becker Operations Manager President Packaging Specialist (828)397-5501 (828)397-5501 (828)397-5501 Compliance Data Comments: Inspection Date O1/09/2019 Inspector's Name Bob Graves Inspector's Signature: C� ytiCoy� �_ Operating Status Operating Compliance Code Compliance-inspection Action Code FCE Date of Signature: — �' 2 J I ] On-Site Inspection Result Compliance Total Actual emissions in TONS/YEAR: TSP SO2 NOX VOC CO PMIO *HAP 2012 107.66 --- --- --- -- 5.14 --- 2008 14.53 --- --- 0.1700 --- Highest HAP Emitted inpounds) Five Year Violation History:None Date Letter Type Rule Violated Violation Resolution Date Performed Stack Tests since last FCE:None Date Test Results Test Method(s) Source(s)Tested Directions: Take I-40 East to Old N. C. Highway 10 (exit 118)and turn right. Follow NC 10 for a short distance(about 25 yards) and then turn left onto Martin Fish Pond Road(SR 1770). Plant is located on the right and the offices are located on the left. Facility Overview This facility manufactures wooden shipping crates(saw and planer lumber). Kontane, Inc. has 60 employees including office staff. Normal operating hours for the facility are Monday- Friday 7am- 4:30pm. Currently five employees work on second shift from 3:30PM- 11:30PM. If the facility contact is not available, ask for Mr. Greg Canter,Operations Manager for the adjacent plant. Safety Required Safety Equipment: Safety shoes and eye protection Inspection Narrative: On January 9,2019,I traveled to the Kontane,Inc. facility to perform an annual unannounced compliance inspection. I arrived approximately 9:42AM, and meet with Mr. Kenny Taylor, Operations Manager. Mr.Taylor said no changes have been made since my last inspection. Permitted air sources: Emission Emission Source Control Control System Source ID Description System ID Description - - - ,one simple cyclone(72 inches in ESA one wood dust collection system C 1 diameter) one simple cyclone(36 inches in ES-B [one wood dust collection system C-2 diameter) one rotary type wood grinder ES C N/A N/A (480 Volt electric-powered) This facility is permitted to operate two simple cyclones (72 and 36 inches in diameter, respectively) (Emission Source ID ES-A and ES-B) installed on wood sawing equipment(wood dust collection system) (Control Device CD-1 and CD-2). Cyclones: Both cyclones were observed in operation. No visible emissions violations were observed from the cyclone exhaust. Mr. Taylor said the dust bins are usually emptied every 3'day when the plant is operating. Compliance is indicated. Both cyclones appeared to be in good condition. Rotary-type wood igr nder:A rotary-type wood grinder(Emission Source ID-ES-C) (480-volt electric- powered)was observed in operation with no VE. The grinder appears to be operating in compliance. Inspection and Maintenance Logbook Review The facility is required to maintain a Cyclone Inspection and Maintenance(I&M)Logbook. The facility performs inspections of each cyclone system and records it into a logbook. All maintenance activities and visual observations are recorded in a logbook. C-2(smaller cyclone)was inspected internally on 11/27/18, 8/14/2018, and 5/16/2018. C-1 was inspected on 11/27/2018, 8/14/2018, and 5/16/2018. Compliance is indicated. Stack Test Review This facility does not have a stack test requirement in their current permit. 112r Review Kontane,Inc. is not subject to 112r. Compliance history No NOV's have been issued in the last five years. Reporting Requirement The facility currently has no reporting requirement. Compliance Assistance: None Recommendations: None Conclusion Based upon records review and visual observations, Kontane,Inc. appeared to be in operating in compliance with Air Permit 06457/R06 during the inspection.