HomeMy WebLinkAboutAQ_F_1900106_20180917_ST_RvwLtr +o STATE o-
ROY COOPER `
Governor •; y
MICHAEL S.REGAN `
Secretary `' C
� An n,pts Pa .:
MICHAEL ABRACZINSKAS ice'
Director
NORTH CAROLINA
Environmental Quality
September 17, 2018
Douglas Palmore, Senior V.P. Customer&Tech. Services
Luck Stone Corporation—Pittsboro Plant
P.O. Box 29682
Richmond, VA 23242
Subject: Luck Stone Corporation—Pittsboro Plant
Moncure, Chatham County,North Carolina
Facility ID: 1900106; Current Air Permit No. 09011/R03
EPA Method 9 Testing of new Crusher and Conveyors
Test Date: August 24, 2018
Stack Test Tracking No.: 2018- 232ST
Dear Mr. Palmore:
On August 31, 2018,this office received the results from an EPA Method 9 test performed on
August 24, 2018 at the subject facility. The testing was completed on the newly installed crusher and
conveyors to demonstrate compliance with 40 CFR Part 60 (NSPS) Subpart 000—Standards of
Performance for Nonmetallic Mineral Processing Plants. The EPA Method 9 test results were reviewed
and found to be acceptable and demonstrate that the Pittsboro Plant was in compliance with the
applicable visible emission standards during the testing period.
As required by 40 CFR 60, Subpart 000, including Subpart A "General Provisions", visible
emissions from crushers are limited to 12% opacity; visible emissions from conveyor belts are limited to
7%opacity. When determining compliance, the duration of the Method 9 test must be 30 minutes (5-6-
minute averages). The highest six-minute average during the testing period was 5.21% for the crushers,
which is below the 12%limit; the highest six-minute average for the conveyors was 0%which is below
the 7% opacity limit.
As a reminder, 40 CFR 60, Appendix A describes the reference methods for future Method 9
testing. If you have any questions concerning this matter, please contact Dawn Reddix, Environmental
Engineer, or me at(919) 791-4200.
Sincerely, �Vh
WViam T. Wike, Jr., P.E., Compia.nce Supervisor
Raleigh Regional Office
Division of Air Quality
cc: RRO Files
North Carolina Department of Environmental Quality I Division of Air Quality
EQ5 Raleigh Regional Office 13800 Barrett Drive I Raleigh,North Carolina 27609
r.onr-r cnraouun
919.791.4200 T 1919,881.2261 F