Loading...
HomeMy WebLinkAboutAQ_F_0800044_20191121_ST_ProtRvw_2019-311st srwtip.w�� 'Pr Q :. ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary MICHAEL ABRACZINSKAS Director November 21,2019 Mr.Brian Connor Avoca,LLC 841 Avoca Farm Road Merry Hill,NC 27957 Subject: Avoca Incorporated Merry Hill,Bertie County,North Carolina Facility ID 0800044,Permit No. 01819T53 Proposed Particulate Matter, Hydrogen Chloride,Carbon Monoxide and Mercury Emissions Testing of Biomass Boilers ES-BB 1 and ES-BB2 By McHale Emissions Measurement Services(EMS),December 2019 DAQ Tracking No. 2019-311 ST Dear Mr. Connor: The North Carolina Division of Air Quality(DAQ)has reviewed the protocol submittal form(PSF)for the emissions testing of biomass boilers ES-BB 1 and ES-BB2. McHale EMS has proposed EPA Method 5 for particulate matter(PM), EPA Method 26A for hydrogen chloride(HCl),EPA Method 10 for carbon monoxide(CO), and EPA Method 30B for mercury(Hg). The proposed testing is acceptable for demonstrating compliance with the applicable regulations. ES-BB 1 and ES-BB2 are two biomass/bio-based solids-fired boilers(24 million Btu per hour maximum permitted heat input rate each)controlled by bagfilter CD-BB1BH. 15A NCAC 2D .0503 Particulates From Fuel Burning Indirect Heat Exchangers and 40 CFR 63 Subpart DDDDD National Emissions Standards for Hazardous Air Pollutants for Industrial, Commercial, and Institutional Boilers and Process Heaters apply to the biomass boilers. The emissions limits and regulations are shown in the table below. Pollutant EPA Test Method Emission Limit' Re ulation Filterable PM 5 0.33 lb/mmBtu 2D.0503 0.0301b/mmBtu HCl 26A 0.0221b/mmBtu CO 10 620 ppmvd@3%O2 63 Subpart DDDDD 3-run average) H 30B 8.0E-071b/mmBtu ' lb/mmBtu=pounds per million Btu;ppmvd@3%02=parts per million by volume dry at 3%oxygen M26A requires an audit sample be present during sampling for inspection if commercially available. However, since provider does not meet the requirement,NC DAQ continues to recommend obtaining an audit sample to support the data generated during a compliance test. E NORTH CnROLIN� f North Carolina Department of Environmental Quality I Division of Air Quality 217 West Jones Street 1 1641 Mail Service Center I Raleigh,North Carolina 27699-1641 919.707.8400 Mr.Brian Connor Page 2 DAQ Tracking No. 2019-311 ST The proposed testing is acceptable for demonstrating compliance with the applicable regulations. Approval of the proposed methods does not exempt the tester from the minimum requirements of the applicable test methods. Any deviations from the applicable methods remain subject to approval by DAQ. If there are any questions regarding this review,please contact me at(919)707-8427 or Brent.Hall(u)ncdenr. ov. Sincerely, p� rent W. Hall Special Projects Engineer Cc: Michael Dickerson,McHale EMS Robert Fisher,WARO Central Files,Bertie County IBEAM Documents-0800044