HomeMy WebLinkAboutAQ_F_1800587_20190829_CMPL_CAV-Rpt NORTH CAROLINA DIVISION OF Mooresville Regional Office
AIR QUALITY Turbocoating Corporation
NC Facility ID 1800587
Inspection Report County/FIPS: Catawba/035
Date: 08/29/2019
Facility Data Permit Data
Turbocoating Corporation [Permit
n/a1928 Main Avenue SE sued n/a
Hickory,NC 28602 xpires n/a
Lat: 35d 43.8148m Long: 81d 18.5706m ass/Status Permit Exempt
SIC: 3479/Metal Coating And Allied Services,nec Permit Status Inactive
NAICS: 332812/Metal Coating,Engraving(except Jewelry and Silverware),and Current Permit Application(s)None
Allied Services to Manufacturers
Program Applicability
Contact Data
SIP
Facility Contact [General
thorized Contact Technical Contact
Warren Smathers Leo Keith Setzer
EHS Manager Manager Maintenance Manager
(828)455-5280 578-5290 (828)455-9554
Compliance Data
Comments:
Inspection Date 08/29/2019
Inspector's Name Deborah Manning
Inspector's Signature: /�� Operating Status Operating
Compliance Code Compliance-inspection
9 Action Code FCE
Date of Signature: / L ,5 On-Site Inspection Result Compliance
Total Actual emissions in TONS/YEAR:
TSP SO2 NOX VOC CO PM10 *HAP
No emissions inventory on record.
* Highest HAP Emitted inpounds)
Five Year Violation History:None
Date Letter Tvne Rule Violated Violation Resolution Date
Performed Stack Tests since last FCE: None
Date Test Results Test Method(s) Source(s)Tested
Turbocoating Corporation
August 29,2019
Page No. 2
Type Action: X Compliance —Partial Compliance _Complaint Other:
Assurance Visit Evaluation/Reinspection Investigation
Data Date submitted for initial review 09/16/2019 IBEAM WARNING/OB,NOD,NOV,NRE
Tracking: X IBEAM Document
X IBEAM Inspection, list date inspected IBEAM LAT/LONG, Facility Locked
X IBEAM Inspection, list date draft is submitted X IBEAM LAT/LONG, Coordinates checked
X IBEAM Inspection,pollutants/programs checked IBEAM Complaint
X IBEAM Planning,Next Inspection Date
08/01/2021
Directions: From Mooresville take 1-77 North to Statesville. Take I-40 west toward Hickory and take
Exit 126. Turn right on McDonald Parkway SE. Turn left on 21' St. Dr. SE. Make a left onto Main Ave
SE. The facility is located on the left at 1928 Main Avenue SE.
Safety Equipment(Issues: Safety glasses and hearing protection are recommended for walking through
this facility.No safety issues were noted at the time of this inspection.
Lat/Long Coordinates: The facility's coordinates on "Maps of DAQ Regulated Facilities" are not
available on the DAQ website. IBEAM indicates that the facility latitude and longitude coordinates are 35d
43.8148m and 81 d 185706m. According to google maps, 81d 18.199 is a more accurate longitude for this
facility.
Facility Email/Contact information: The facility contacts information, including email addresses, were
verified during this compliance assurance visit.Updates were made in the IBEAM database.
General Information: The purpose of this site visit was to conduct a routine compliance assurance visit.
This facility provides coating and post-coating treatments using thermal spray technology for land-based
gas turbines and aircraft engines. The facility currently operates three shifts per day, Monday through
Friday. Depending on product demand, one or two shifts may operate on the weekend. The facility
currently employs 94 workers. Matthew Hill and I arrived at the facility on August 29, 2019 at
approximately 10:45 AM and met with Mr. Warren Smathers, EHS manager. Mr. Smathers accompanied
us during this inspection and provided the requested documentation.
Source Observations:
The facility currently operates 11 powder coating booths. Raw materials (powders or pellets)are made
into a slurry which are then robotically sprayed on an object inside an enclosed container/spraybooth.
Each booth is controlled with a cartridge filter. The facility also maintains (1) one 20% by volume HCl
tank(approximately 100 gallons)that is controlled by a wet scrubber. This tank, as well as the three
associated rinse tanks, are not part of the production process. They are used by the test laboratory to strip
parts that have been coated by a programing error.
Exemption Oualification: A permit applicability determination was conducted by this office on April 12,
2012, April 17, 2013, and December 7, 2017. All determination reviews indicated that a permit was not
required by this facility. Facility records indicated that production has not increased since the most recent
permit determination conducted by this office.
Turbocoating Corporation
August 29, 2019
Page No, 3
NSPS/NESHAP Review: The facility does not have any generators, fire pumps, boilers, or gasoline
storage tanks,and is not subject to NESHAP Subpart 4Z,NESHAP Subpart 6J,or NESHAP 6C,
respectively.
This facility is not subject to 40 CFR 63 Subpart HIIHHHH, "NESHAP: Paint
Stripping and Miscellaneous Surface Coating Operations at Area Sources"because materials
used do not contain any of the target HAPs.
Also,this facility is not subject to 40 CFR 63 Subpart XXXXXX, "NESHAP: Area Source Standards for
Nine Metal Fabrication and Finishing Source Categories" because materials used do not contain target
HAPs and the NAICS code of 332812 is not one of the codes listed in the rule as an applicable code.
Compliance determination: Based on my observations,this facility appeared to be in compliance with the
air quality rules (2D .0521-visible emissions; 2D .0515-particulates from miscellaneous industrial
processes; 2D .0535-excess emissions; 2D .0540-fugitive dust emissions; and 2D .1806-odors) at the time
of the visit.
DWM:Ihe
cc: MRO File
https://ncconnect.shuepoint.con✓sites/DAQ-MRO/Coun6es/CATA WBA/00587/INSPECT_20190829_CAV.docx