HomeMy WebLinkAboutAQ_F_2000126_20200513_CMPL_CAV-Rpt (4) � c� UO12U — CAV NORTH CAROLINA DIVISION OF Asheville Regional Office AIR QUALITY Southern Concrete Materials Inc.-Ranger NC Facility ID 2000126 Compliance Assurance Visit(CAV)Report: Partial Compliance Evaluation County/FIPS: Cherokee/039 Date: 05/19/2020 Facility Data Permit Data Southern Concrete Materials Inc.-Ranger Permit n/a 395 Wingate Road Issued n/a Murphy,NC 28906 Expires n/a Lat: 35d 1.7340m Long: 84d 7.9510m Class/Status Permit Exempt SIC: 3273 /Ready-Mixed Concrete Permit Status Inactive NAICS: 32732/Ready-Mix Concrete Manufacturing Current Permit Application(s)None Contact Data Program Applicability Facility Contact Authorized Contact Technical Contact SIP Thomas Ledford Jeff Lamm Jeff Lamm Division Manager Vice Vice (706)781-2092 President/Environmental Presidem/Environmental Affairs Affairs (828)253-6421 (828)253-6421 Compliance Data Comments: Inspection Date 05/13/2020 Inspector's Name Richard Morris Inspector's Signature: X/ � J� Operating Status Operating o l Compliance Code Compliance-inspection Action Code PCE Date of Signature: 7� �� ' 2,v On-Site Inspection Result Compliance Total Actual emissions in TONS/YEAR: TSP S02 NOX VOC CO PM10 *HAP 2012 --- --- --- --- --- --- --- 2007 --- 0.0000 --- 0.0000 0.0000 *Highest HAP Emitted(inpounds) Five Year Violation History:None Date Letter Type Rule Violated Violation Resolution Date Performed Stack Tests since last FCE:None Date Test Results Test Method(s) Source(s)Tested Compliance Assurance Visit (CAV) Report: Partial Compliance Evaluation 1) Location: Southern Concrete Materials Inc. - Ranger is located at 395 Wingate Road in Ranger,NC. Cherokee Co. Directions: Take Hwy 19/74/129 from Murphy to Hwy 64/74 West to Ranger. Follow 64 west for approximately 11 miles. The facility is located off of the Hwy on the right. 2) Facility Overview: Southern Concrete Materials Inc. - Ranger is a concrete batch plant,producing concrete for commercial use. This facility is permit exempt effective August 5, 2016. Last compliance inspection conducted on August 10, 2018 by Richard Morris Safety: Steel toed shoes, eye protection Current throughputs: Facility is not operating. Pre-inspection Conference: On May 13,2020, I, Richard Morris with NC Air Quality, called and spoke with Thomas Ledford who is the Facility Contact for Southern Concrete Materials Inc. —Ranger. No site visit was made due to the Covid-19 stay-in-place order. I asked to conduct a Partial Compliance Evaluation which is not an onsite visit. Mr. Thompson is the Western Area Division Manager and told me that this plant has not operated since my last visit on July 30, 2019. He informed me that this plant was used as a back-up for the Andrews Plant on the Cherokee Casino. Very little production occurs at this plant. There are no plans to run this facility full time in the near future. Process Description: (AP-42) Concrete is composed essentially of water, cement,sand(fine aggregate), and coarse aggregate. Coarse aggregate may consist of gravel, crushed stone, or iron blast furnace slag. Some specialty aggregate products could be either heavyweight aggregate (of barite,magnetite, limonite, ilmenite, iron, or steel) or lightweight aggregate (with sintered clay, shale, slate, diatomaceous shale, perlite,vermiculite, slag, pumice, cinders, or sintered fly ash). Concrete hatching plants store, convey,measure, and discharge these constituents into trucks for transport to a job site. In some cases, concrete is prepared at a building construction site or for the manufacture of concrete products such as pipes and prefabricated construction parts. The raw materials can be delivered to a plant by rail, truck, or barge. The cement is transferred to elevated storage silos pneumatically or by bucket elevator. The sand and coarse aggregate are transferred to elevated bins by front end loader, clam shell crane, belt conveyor, or bucket elevator. From these elevated bins, the constituents are fed by gravity or screw conveyor to weigh hoppers, which combine the proper amounts of each material. Truck mixed(transit mixed) concrete involves approximately 75 percent of U. S. concrete hatching plants. At these plants, sand, aggregate, cement, and water are all gravity fed from the weigh hopper into the mixer trucks. The concrete is mixed on the way to the site where the concrete is to be poured. Central mix facilities (including shrink mixed) constitute the other one-fourth of the industry. With these, concrete is mixed and then transferred to either an open bed dump truck or an agitator truck for transport to the job site. Shrink mixed concrete is concrete that is partially mixed at the central mix plant and then completely mixed in a truck mixer on the way to the job site. Dry batching, with concrete mixed and hauled to the construction site in dry form, is seldom, if ever,used. Inspection: Plant not operating. 3) Emission Source and Regulatory Review: Sources are: (from last permit) _..... --- -- -- ------_. _._. .. .... Emission Emission Source Control Control System Source ID Description System ID Description ;CSC__-___-----p ���� _ _ l One truck mix concrete batch plant(maximum rated capacity of 100 cubic yards of concrete per hour) consisting of the following: ES 1 one flyash storage silo(75 tons of flyash CD-5 one bagfilter(170 square feet of storage capacity) 1� I filter area) _ one cement storage silo(100 tons of cement one bagfilter(156 square feet of storage capacity) _� CD-1 ES 2 LE� filter area) one cement weigh hopper(100 cubic yards of one bagfilter(27 square feet of I ES-4 lconcrete per hour maximum batching CD-3 (filter area) capacity) !I[ one water spray system(1.5 ES-5 Foneoncrete truck load out operation CD-4 gallons per minute min mum water flow) j Insignificant Sources: Source Exemption Source of Source of Title V Regulation_: TAPs?J Pollutants? f I I -one natural as-fired boiler 2.2 million 2 0102 yes Yes hour maximum heat input rate) (— p (c)O(B)(li) I-2-Sand and aggregate delivery to ground storage, 2Q.0102 No Yes transfer to conveyor, and transfer to elevated storage I (c()(E)(i) I-3 -Sand and aggregate weigh hopper g�. O� No Yes I. Applicable Regulations The Company must comply with the following EMC Regulations for this application: 15A NCAC 2D .0515, "Particulates from Miscellaneous Industrial Processes" 15A NCAC 2D .0521, "Control of Visible Emissions" 15A NCAC 2D .0535, "Excess Emissions Reporting and Malfunctions" 15A NCAC 2D .0540, "Particulates from Fugitive Dust Emission Sources" 15A NCAC 2Q .0102, "Activities Exempted from Permit Requirements" 15A NCAC 2Q .0711, "Emission Rates Requiring a Permit" Reporting requirements: None 4) Compliance History Review: None 5) Stack Test Review: Not required 6) 112R Status: Based on the facility's inventory, it was decided that they are not subject to 112R reporting requirements 7) Comments and Compliance Statement: MIAMI- /rem