Loading...
HomeMy WebLinkAboutAQ_F_0800018_20200416_CMPL_InspRpt (4) NORTH CAROLINA DIVISION OF Washington Regional Office AIR QUALITY Rose Brothers Paving Co Inc. -Windsor NC Facility ID 0800018 Inspection Report County/FIPS:Bertie/015 Date: 04/16/2020 Facility Data Permit Data Rose Brothers Paving Co Inc. -Windsor Permit 03707/R18 129 County Farm Road(SR 1527) Issued 3/21/2017 Lewiston Woodville,NC 27849 Expires 2/28/2025 Lat: 35d 58.8630m Long: 76d 57.0360m Class/Statu Synthetic Minor SIC: 2951 /Paving Mixtures And Blocks Permit Status Active NAICS: 324121 /Asphalt Paving Mixture and Block Manufacturing Current Permit Application(s)None Contact Data Program Applicability Facility Contact Authorized Contact Technical Contact SIP Tim Perry Tim Perry Tim Perry Plant Superintendent Plant Superintendent Plant Superintendent (252)287-7829 (252)287-7829 (252)287-7829 Compliance Data Comments: A partial compliance evaluation(PCE)was completed for the facility via file review and facility contact interview. The PCE was Inspection Date 04/16/2020 conducted during the Covid-19 teleworking period. No issues were Inspector's Name Kurt Tidd discovered. Operating Status Operating Compliance Code Compliance-inspection Action Code PCE n� On-Site Inspection Result Compliance Inspector's Signature: �L Date of Signature: 04/16/2020 Total Actual emissions in TONS/YEAR: TSP S02 NOX VOC CO PM10 * HAP 2015 0.4800 1.12 1.28 0.4000 4.07 0.3000 54.58 2011 0.7100 1.68 2.04 0.6600 6.62 0.4600 89.40 * Highest HAP Emitted(in pounds) Five Year Violation History:None Performed Stack Tests since last FCE:None Location: This facility is in Windsor, Bertie County, NC. From WaRO take Hwy 17 North to the junction of Hwy 17/Hwy 64. Turn on Hwy 64 East/17 North, south of Williamston, and follow Hwy 17/13 North. Prior to the separation of Hwy 13/17 North, turn right onto Country Farm Road (SR1527) at the North Carolina National Guard Armory. The facility is located about half a mile on the left. Safety: PPE should be used at the facility. The inspector will need a hard hat, safety glasses, hearing protection, and safety shoes. Additionally, a safety vest should be worn when you inspect the yard. Facility Summary: The facility is a 250-ton/hr batch asphalt mixing plant. The aggregate is conveyed to a drum where it is dried. A screening process then separates the aggregate. The aggregate is then mixed in the desired proportions, injected with asphalt, weighed and unloaded into trucks and transported to job sites. This facility has a multi-site permit that allows for them to locate in Lewiston or Windsor; both sites are in Bertie County. List of Permitted Sources: Emission Emission Source Control Control System Source ID Description System ID Description ES-1 Nos. 2 and 4/Nos. 2 and 4 equivalent waste fuel oil-fired 24768,Ra-15-60 Simple cyclone (120 batch asphalt plant, 250 tons per hour maximum in), Bagfilter (11,466 sq production capacity, 84 million Btu per hour maximum ft) heat input, allowed to utilize recycled, post consumer waste, asphalt (asbestos-free) shingles as an option in the mix GS3630AR/HC 50 TPH asphalt and concrete crusher N/A N/A Inspection Results: On 4/16/2020, I conducted a Partial Compliance Evaluation (PCE) of the Rose Brothers Paving Company's asphalt plant located in Windsor,NC by telephone due to the COVID 19 outbreak. I talked with Tim Perry, plant superintendent for all of the Rose Brothers facilities. Mr. Perry stated that the Windsor plant had been operating and had produced between 5000 and 6000 tons of asphalt so far this year. I asked if there had been any issues with the plant and he stated that the plant had only been used a limited time and there have been no issues. All reports and monitoring are up to date including the shingle use reports. He also stated that he observes this facility at least once per week when it is operating and has not seen any visible emissions from it or fugitives from the yard. I reviewed the reports in I Beam and did not see any issues or complaints from this facility. There is no testing scheduled at this time. A partial compliance evaluation (PCE) was completed for the facility via file review and facility contact interview. The PCE was conducted during the COVID-19 teleworking period. No issues were discovered.