Loading...
HomeMy WebLinkAboutAQ_F_0100237_20200326_CMPL_NOV-NRE (4) ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary MICHAEL ABRACZINSKAS March 26, 2020 Director Mr. Mark Blalock General Manager Canfor Southern Pine—Graham Plant 4408 Mt. Hermon-Rock Creek Road Graham,North Carolina 27253-8909 SUBJECT: Notice of Violation/Notice of Recommendation for Enforcement 40 CFR Part 63, Subpart A Requirements Canfor Southern Pine—Graham Plant Graham,Alamance County,North Carolina Air Permit No. 06740T22 Facility ID No. 0100237 Fee Class: Title V Dear Mr. Blalock: The Division of Air Quality(DAQ)has reviewed Canfor Southern Pine's"Semiannual Title V Air Permit Report,"submitted on January 30, 2020, as well as additional requested information related to third quarter opacity monitoring emailed by Kristie Hill of your staff on March 16, 2020. The report provided information about the operation of the facility's continuous opacity monitoring systems (COMS)during the third and fourth quarters of 2019. Our review of the third quarter report and subsequent email, confirmed the amount of monitor downtime was excessive and indicative of improper operation and maintenance(O&M) of the COMS on Boilers Nos. 2, 3 and 4 (ID Nos. B-2,B-3 &B-4). Boiler No. 2 operated for 105,960 minutes with 72,804 minutes (equal to 68.7%) of monitor downtime,Boiler No. 3 operated for 108,540 minutes with 72,912 minutes (equal to 67.2%) of monitor downtime, and Boiler No. 4 operated for 106,320 minutes with 72,708 minutes(equal to 68.4%) of monitor downtime. The COMS downtime was attributed to a communication error that caused the data acquisition system to stop recording opacity readings from the COMS units between July 6, 2019 and August 26, 2019. DAQ considers COMS sources with percent monitor downtime(%MD) greater than 6% for any single calendar quarter or greater than 3% for two consecutive quarters, to have operated with improper O&M practices. The failure to exercise proper O&M practices is a violation of Section 3, General Condition F of Air Quality Permit No. 06740T22; therefore,this letter serves as a Notice of Violation (NOV) of 15A NCAC 02D .1111 "Maximum Achievable Control Technology(MACT)" as promulgated in 40 CFR Part 63, Subpart A for not KURMOMM�EQS North Carolina Department of Environmental Quality I Division of Air Quality 217 West Jones Street 1 1641 Mail Service Center I Raleigh.North Carolina 27699-1641 919.707.8400 Mr. Mark Blalock March 26, 2020 Page 2 complying with the provisions of§63.6 as well as the general duty requirement of §63.860(d)for Boilers Nos.2,3, and 4. Additionally,for Boiler No.4,this is a violation of 15A NCAC 02D .0524 "New Source Performance Standards (NSPS)" as promulgated in 40 CFR Part 60, Subpart A for not complying with the provisions of§60.13. As a result of the excessive monitor downtime, this letter also serves as a Notice of Recommendation for Enforcement(NRE). An enforcement report is being prepared by this office addressing these violations. It is requested that a written response to this NOWNRE be submitted as soon as possible, but not later than April 30,2020. The response should outline the steps that you plan to take or have taken to assure compliance with the aforementioned requirements at all times. These violations can result in possible civil penalties as per North Carolina General Statute 143-215.114A. A civil penalty may be assessed against a company who violates or fails to act in accordance with the terms, conditions, and/or requirements of any permit issued under General Statute 143-215.108. As an additional reminder, this Notice of Violation is required to be referenced in your facility's annual compliance certification(ACC), in accordance with Section 3, General Condition P of your Title V permit. Your cooperation and concern for the environment are appreciated. If you should have any questions,please contact Alan Drake of my staff at(919) 707-8493. Sincerely, 2� -,Z- d, d-41 Stephen G. Hall, Chief Technical Services Section Division of Air Quality,NCDEQ SGH/ad c: Kristie Hill, Canfor Southern Pine(e-copy) Lisa Edwards, DAQ WSRO Gary Saunders, DAQ RCO (e-copy) IBEAM Documents, 0100237 (e-copy) Central File, Alamance County