HomeMy WebLinkAboutAQ_F_0100237_20200319_CEM_RptRvwLtr (4) QINM1 ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary MICHAEL ABRACZINSKAS Director March 19, 2020 Mr. Mark Blalock General Manager Canfor Southern Pine—Graham Plant 4408 Mt. Hermon-Rock Creek Road Graham,North Carolina 27253-8909 SUBJECT: Review of 2019 Semiannual COMS Report, Second Half Canfor Southern Pine—Graham Plant Graham, Alamance County,North Carolina Air Permit No. 06740T22 Facility ID No. 0100237 Dear Mr. Blalock: Thank you for your timely submittal of the subject report, dated January 30, 2020, from Canfor Southern Pine's Graham Plant. The report included an assessment of the continuous opacity monitoring systems (COMS)that operated on Boilers Nos. 2, 3 and 4 (ID Nos. B-2, B-3 & B-4) during the second half of 2019. Additional requested information regarding monitor downtime during the third quarter was provided by Kristie Hill of your staff on March 16, 2020. The Division of Air Quality(DAQ)has completed its review of the COMS-related information in the report and has the following comments: I. Wood fuel-fired boilers B-2, B-3 and B-4 were reviewed for compliance with the 10% opacity operating limit (6-minute period, daily block average) set forth in NCAC 02D .1 111 (40 CFR, Subpart 63, DDDDD—National Emission Standards for Hazardous Air Pollutants for Major Sources:Industrial, Commercial, and Institutional Boilers and Process Heaters) and Air Permit No. 06740, Specific Condition 2.2.C.La. The COMS report indicated there were no violations of the applicable standard. 2. Wood fuel-fired boiler B-4 was also reviewed for compliance with the 20% opacity limit (6-minute period) set forth at NCAC 02D .0524(40 CFR Part 60, Subpart Dc—Standards of Performance for Small Industrial-Commercial-Institutional Steam Generating Units) and Air Permit No. 06740 specific condition 2.1.AA.d. The COMS report indicated there were no violations of the applicable standard. Excess emissions from the wood-fired boiler were attributed to either startup, shutdown,malfunction, or other exempt emissions. These emissions were reviewed and allowed in accordance with applicable monitoring rules. NORT�CARO�LINA oewe i of 9.m w Uutlla North Carolina Department of Environmental Quality I Division of Air Quality 217 West Jones Street 1 1641 Mail Service Center I Raleigh,North Carolina 27699-1641 919.707.8400 Mr. Mark Blalock March 19, 2020 Page 2 3. A review was also conducted for compliance with good operation and maintenance(O&M) practices pursuant to NCAC 2D .0524 (NSPS Dc, including Subpart A- General Provisions), 40 CFR 60.11(d), 40 CFR 60.13(e), and Specific Condition 2.1.A.4; NCAC 2D .1I11 (NESHAPS DDDDD including Subpart A - General Provisions), 40 CFR 63.7500(a), 40 CFR 63.8(c)(4), and Specific Condition 2.2.C.1. When compared to the total operating time of the boilers,percent excess emissions (%EE) and percent monitor downtime(%MD) were reported as follows: Source Quarter %EE %MD Boiler B-2 3rd 0.0 68.7 4th 0.0 0.0 Boiler B-3 3rd 0.0 67.2 4th 0.0 0.0 Boiler B-4 3rd 0.1 68.4 4th 0.0 0.0 Unless otherwise specified in regulation, DAQ considers sources to have operated with good O&M if the %EE and %MD are less than the target criteria of 6% for any single quarter and less than 3% for two consecutive quarters. The facility indicated that during the third quarter of 2019, a malfunction of the data recording system resulted in high%MD for each of the boilers. As a result of excessive %MD during the third quarter,your facility may be subject to an enforcement action beginning with a Notice of Violation (NOV). 4. The first and second quarter audits of the COMS units were reviewed in accordance with Procedure 3 of 40 CFR Part 60, Appendix F - Quality Assurance (QA)Procedures. The QA test results for the COMS appear to have met the quarterly specifications. If you should have any questions,please contact me at(919) 707-8493 or alan.drake@ncdenr.gov. S' cerely, Alan Drake, Environmental Engineer Division of Air Quality,NCDEQ c: Kristie Hill, Canfor Southern Pine(e-copy) Lisa Edwards, DAQ WSRO Gary Saunders, DAQ RCO IBEAM Documents, 0100237 Central File,Alamance County