Loading...
HomeMy WebLinkAboutAQ_F_1200086_20200115_CMPL_InspRpt (4) 16 NORTH CAROLINA DIVISION OF Asheville Regional Office AIR QUALITY Environmental Inks-A Member of the Siegwerk Group Inspection Report NC Facility ID 1200086 Date: 01/17/2020 County/FIPS:Burke/023 Facility Data Permit Data Environmental Inks-A Member of the Siegwerk Group Permit 05478/R12 1 Quality Products Road Issued 12/6/2013 Morganton,NC 28655 Expires 11/30/2021 Lat: 3 5d 42.3 660m Long: 8ld41.9160m Class/Status Small SIC: 2893/Printing Ink Permit Status Active NAICS: 32591 /Printing Ink Manufacturing Current Permit Application(s)None Contact Data Program Applicability Facility Contact Authorized Contact Technical Contact SIP Chad Davis Scott Bartlett Lee Kearson UV Plant Manager Head of Operations Health,Safety& (828)391-2382 (828)391-2383 Environmental Specialist (828)391-2314 Compliance Data Comments: Inspection Date 01/15/2020 i, Inspector's Name Bob Graves Inspector's Signature: v Ca � � Operating Status Operating Compliance Code Compliance-inspection j Action Code FCE Date of Signature: Z On-Site Inspection Result Compliance Total Actual emissions in TONS/YEAR: TSP S02 NOX VOC CO PM10 *HAP 2012 0.0100 --- 0.1500 7.20 0.1200 0.0100 5.29 2007 --- 0.0000 2.90 0.0000 0.0000 --- Five Highest HAP Emitted(in pounds) rYcarlation History:NoneLetter Type Rule Violated Violation Resolution Date ack Tests since last FCE:None Test Results Test Method(s) Source(s)Tested Directions: From Asheville, take 1-40 East to exit 103. Turn right onto Highway 64. Go less than one mile, and then turn left onto Craftsman Drive. The facility is located approximately 200 yards on the right. Safety E ui ment: Safety glasses and safety shoes. 1. Facility Overview Discussion/Introduction On January 15,2020,I,Bob Graves met with Chad Davis,Plant Manager,and Mr.Ray Robinson,Engineering and Facilities Manager,and Mr. Lee Kearson,HSE Coordinator,to conduct an annual compliance inspection. During the inspection, Mr.Robinson helped in the identification of the emission sources and control devices and gave access to maintenance records. Everything appeared to be in order. If the facility contact is not available for an inspection,ask for Mr.Ray Robinson,Engineering(cell 828-448-4966), or Mr. Ronnie Murphy,Maintenance Supervisor(828-391-2315, or 828-448-8028),and Mr.Lee Kearson,HSE Coordinator. Facility Contacts The contacts shown above are current. Facility Description Environmental Inks and Coatings manufactures water-based inks for use in rotogravure and flexographic printing. These inks are made by mixing resins and water with organic pigments;the approximate percentages are 10-15% pigment,40%resin,and 50%water. Ammonium hydroxide is added to achieve the proper pH. The inks are used for film work,lamination(water bottles),and other printing projects. Customers are:Rock Tenn,Valdese Packing, and the Smythe Corp., and others.The facility has been at this location since 1985 and employs approximately 60 people. They operate from 6 am to 10 pm,with the bulk of the production during the hours of 6am to 4 pm,five days per week. 2. Emission Source and Regulatory Review Source Listing --- - ._._-- ---- ----._ ----. _..._.--- -- .---- . Emission Emission Source Control Source ID !, escri Dption System Notes Observed not in operation. This is a small-scale [aborat ory pigment blending DC-1 one bagfilter(250 operation where pigments are blended for trial ES-1 erations square feet of filter area) and/or test purposes and operates about an hour per week. —. — —-- _ --- —— waterborne ink manufacturing DC-2 one bagfilter(960 Observed in operation with no VE. The facility ES-2 ! would like to replace this baghouse in near operations square feet of filter area) metre. DC-6 one bagfilter dispersion manufacturing Observed not in operation.Magnehelic gauge ES-4 (2,480 square feet of operations filter area) readings are documented weekly. Permit Conditions • Specific Condition 3: Particulate Control Requirement An allowable particulate emissions rate is calculated based on process weight rate. The last permit review performed this calculation and compliance was indicated. • Specific Condition 4: Visible Emissions Control Requirement Visible emissions from all sources are limited to 20%opacity. No visible emissions were observed from the sources in operation. i i i • Specific Condition 6: Fugitive Dust Control Requirement The facility is not allowed to have dust leave the property and generate complaints from the public. No fugitive dust was observed on or beyond the property boundary. • Specific Condition 7: Fabric Filter Requirements The facility is required to perform,at a minimum,an annual interval inspection of the bagfilter systems, as well as document any maintenance performed. The facility's electronic maintenance system generates work orders to perform monthly inspections on each bagfilter. Mr. Ray Robinson gave access to the electronic logbook inspection and maintenance(I&M)records on the bagfilters. The electronic maintenance system logbook appears to be adequate and up to date. Compliance is indicated. The last inspections for the bagfilter systems: • DC-1 —facility ID#4= 12/16/19(internal inspection&replaced filters). • DC-2=facility ID#2= 11/24/19(internal inspection&replaced filters). • DC-6—facility ID# 1 =3/11/19 (internal inspection). This rule does not apply to the facility. • Specific Condition 9 and 11: NC Toxics Requirements The facility has a modeled limit of 20.12 pounds per hour of ammonia emissions and a general condition of limiting any NC TAPS to less than the TPERs. The highest amount of ammonium hydroxide additions above the formula was well below the permitted limit. The facility tracks ammonia emissions. Compliance is indicated. (see spreadsheet attached) • Specific Condition 10: Control and Prohibition of Odorous Emissions The facility is required to prevent objectionable odorous emissions beyond the property boundaries. Slight odors were detected in the building,but none were detected outside. Compliance is indicated. Record Keeping and Reporting Requirements Review The facility has no reporting requirements. The facility is required to inspect the bagfilter systems once per year and document the results of the inspections and any maintenance activities conducted on the bagfilter systems. The electronic maintenance system logbook appears to be adequate and up to date(see condition No. 7 above). Compliance is indicated. The facility is also required to keep records of additional ammonium hydroxide added to the mix above what is in the mix. These records are kept electronically and appear adequate. Compliance is indicated. Insignificant Sources Listing Emission [7R7egulation ptton Source Notes Source ID ' natural gas-fired boiler(1.83 million Btu per 2Q .0102 Removed from service A I-1 pressure washer is in this hour maximum heat input rate) (c)(2)(B)(i)(I) storage room. 3. Compliance History Review There have been no documented violations in the past five years. One unsubstantiated dust complaint was received on April 30,2018. 4. Stack Test Review The facility has had no stack test requirements. 5. 112r Review The facility is not subject to 112r. 6. Compliance Assistance None. 7. Recommendation/Conclusion/Compliance Statement Based on review of records and visual observations,this facility appeared to be operating in compliance with the Air Quality standards and regulations at the time of this inspection. Morganton Ammonia Emissions 2019 Batches with AA0600 ingredient 0.0777 168 Monthly NH3 Month Total Lbs. Number of Month Lbs. NH3 Emission Rate Average Size Month AA0600 Usage Batches Emissions Lbs/Hr. Batch (Lbs) January j 7,215 526 40.9 0.24! 784 February F__ 6977 378 29.40 0.17I 1,074 -- I ----I 0 I-_ March 6,769 435 33.8 0.20i 1,003 April L 6,122 360 28.0 0 17: 1,004 May — -- 5474 _ 342 26.6 0.1&s 1,055 0 I. -- June C-- 5549-- 378 294 0.17; 1;085 July 7,463 466 36.2` 0.22t 1,089_ 0 . — August � _8;6� _ 4091 318� 019 i -- 1,196 September [ 4 209 _ 340 26.4 0.16t 1,056 October f 7131 340 26.4 0.16! 1,048 — — - November 7,523 _ 225 17:5 0 10y 1,557 December 0.0 0.00 TOTALS 73,039 4199 326.26' Aqua Ammonia Solution (AA0600) 0.74 Water 0.26 Ammonium Hydroxide Data comes Nom IftrIms ace Re r i 6rt CIntranet favorites for link