HomeMy WebLinkAboutAQ_F_1800419_20200212_ST_ProtRvw (4) ROY COOPER NORTH CAROLINA
Governor Environmental Quality
MICHAEL S.REGAN
Secretary
MICHAEL ABRACZINSKAS
Director February 11,2020
Mr.Rick Miller
Prysmian Cables and Systems USA,LLC
2512 Penny Road
Claremont,NC 28610
Subject: Prysmian Cables and Systems USA,LLC
Claremont,Catawba County,North Carolina
Facility ID 18-00419,Air Permit No.07334T29,DAQ Tracking No.2020-023ST
Nitrogen Oxides Testing Protocol of Two Over-cladding Units ES-9 and ES-9a
By McHale Environmental,Proposed Test Date:February 26,2020
Dear Mr.Miller:
McHale Environmental proposes EPA Method 7E for nitrogen oxides(NOx)emissions from over-cladding units
ES-9 and ES-9a.The proposed testing is acceptable for demonstrating compliance with the applicable regulations.
Emission source ES-9 consists of over-cladding units: Cell 4 and four Cell 5 units venting to a hydrated lime
injection dry scrubber fabric filter system IDS venting to selective catalytic NOx reduction system 1SCR. Emission
source ES-9a consists of over-cladding units: Cells 6,7,and remaining Cell 5 units venting to a hydrated lime
injection dry scrubber fabric filter system 2DS venting to selective catalytic NO,,reduction system 2SCR.
15A NCAC 2Q .0317 Avoidance Conditions for 15A NCAC 2D.0530 Prevention of Significant Deterioration
applies. Permit Condition 2.2.A.l.a. states"Total emissions of nitrogen oxides from equipment in Cells 1,2,3,
and 4 and two boilers shall be less than 250 tons per consecutive 12-month period." Permit Condition 2.2.A.1.c
requires"Uncontrolled NOx emissions from individual small and large torch Over-cladding Units(Cells 4;ID No.
ES-9)shall be tested to determine emission rates in pounds of NOx per unit-hour to be used in demonstrating
compliance with the PSD avoidance condition."Permit condition 2.2.B.l.c states"NOx uncontrolled emissions
from individual new technology torch Over-cladding Units(Cells 5,6,and 7,ES-9a)shall be tested to determine
emission rates in pounds of NOx per unit-hour to be used in demonstrating compliance with the PSD avoidance
condition."
The PSF indicates"prior testing has shown source to emit essentially air,02...a dry MW of 29.0 shall be assigned."
The molecular weight of 29.0 is acceptable. The proposed testing is acceptable. Approval of the protocol does not
exempt the tester from the minimum requirements of the sampling methods. Any deviations remain subject to
approval by DAQ. If there are any questions regarding this review,please contact me at(919)707-8427 or
Brent.Hall(�cdenr.gov.
Sincerely,
Brent W.Hall
Special Projects Engineer
Cc: Michael Dickerson,McHale Bruce Ingle,MRO
Central Files,Catawba County IBEAM Documents- 1800419
NORT�CAFla�JN �
DRWftnW1ar
North Carolina Department of Environmental Quality I Division of Air Quality
217 West ones Street 11641 Mail Service Center I Raleigh,North Carolina 27699-1641
919.707.8400