Loading...
HomeMy WebLinkAboutAQ_F_0100237_20210128_ST_ProtRvw � srnrf ofA• ai - lA ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary January 28, 2021 MICHAEL ABRACZINSKAS Director Kristie Hill Canfor Southern Pine-Graham Plant 4408 Mount Herman-Rock Creek Road Graham,North Carolina 27253 Subject: Canfor Southern Pine—Graham Plant, Graham,Alamance County,North Carolina Facility ID 0100237,Air Permit No. 06740T21 Particulate Matter and Carbon Monoxide Emissions Testing Protocol for Boiler B-4 Proposed Test Date: February 2,2021 by TRC Environmental Corporation DAQ Tracking No. 2021-022st Dear Ms. Hill: The North Carolina Division of Air Quality(DAQ)has reviewed the protocol submittal form(PSF)for the filterable particulate matter(PM)and carbon monoxide(CO)emissions testing of Boiler B-4. The proposed test methods are acceptable to determine compliance with the applicable NSPS emissions limit. Emissions Source B-4 is a wood fuel-fired boiler controlled by two multiclones and an electrostatic precipitator ESP-4. The maximum permitted heat input for B-4 is 57.6 million Btu per hour(mmBtu/hr). The proposed heat input rate for testing 51.8 mmBtu/hr. 40 CFR 63 Subpart DDDDD National Emissions Standards for Hazardous Air Pollutants for Major Sources:Industrial, Commercial and Institutional Boilers and Process Heaters applies and limits filterable PM to 0.037 pounds per million Btu(lb/mmBtu) and limits CO emissions to 15 parts per million corrected to 3%oxygen(ppm@3%02).40 CFR 60 Subpart Dc Standards of Performance for Small Industrial-Commercial-Institutional Steam Generating Units applies and limits filterable PM to 0.03 Ib/mmBtu. TRC proposes 120-minute runs of EPA Method 5 for filterable PM and EPA Method 10 for CO.The PSF indicate the following boiler/control parameters will be monitored every 15 minutes throughout sampling: steam flow, steam pressure,oxygen trim,M/C pressure drop,ESP fields 1 and 2 primary(VAC)and secondary(KVDC), and continuous opacity monitoring system(COMS)opacity. The parametric data shall be averaged and reported with the final emissions results.Approval of this protocol does not exempt the tester from the minimum requirements of the methods.Any deviations remain subject to approval by DAQ. If you have any questions,please contact me at shannon.vogel@ncdenr.gov or 919-707-8416. S' cerely, U Shannon Vogel,Env ronmental Engineer Division of Air Quality,NCDEQ cc: Ray Stewart,P.E. Winston Salem Regional Office IBEAM Documents-0100237 Tyler Mills, TRC Environmental Corporation D_E Q om; D pa_W of Enviraamenlal quality North Carolina Department of Environmental Quality I Division of Air Quality 217 West Jones Street 1 1641 Mail Service Center I Raleigh.North Carolina 27699-1641 Q1Q 707 AAC)0 r