HomeMy WebLinkAboutAQ_F_0100010_20211019_ST_RvwMemo (4) DIVISION OF AIR QUALITY
October 19, 2021
MEMORANDUM
To: Ray Stewart, P.E.,Winston Salem Regional Office Supervisor
From: Brent W. Hall, Stationary Source Compliance Branch(SSCB) 532I1m
Subject: Stericycle, Inc.
Haw River, Alamance County,North Carolina
Facility ID 01-00010, Air Permit No. 05896T25
Emissions Testing of Two Dual Chamber Hospital,Medical, and Infectious
Waste Incinerators ESO1 and ES02 by TRC Environmental on April 6 and 7, 2021
DAQ Tracking No. 2021-078ST
TRC Environmental Inc. (TRC)performed EPA Method 5 for particulate matter(PM), EPA Method 29
for metals cadmium(Cd), lead(Pb), and mercury(Hg), EPA Method 26A for hydrogen chloride(HCl),
and EPA Method 9 for visible emissions (VE) from hospital,medical, and infectious waste incinerators
(HMIWI)ES-01 and ES-02. The emissions test results demonstrate compliance with the applicable
regulations.
ESO1 and ES02 are two natural gas-fired dual-chamber HMIWI, each controlled with one selective non-
catalytic reduction(SNCR) system(CD07 and CD08)in series with one packed bed scrubber
(CDO1 and CD02), in series with one venturi scrubber(CD03 and CD04)in series with one impregnated
carbon bed(CD05 and CD06). 15A NCAC 2D .1100 Control of Toxic Air Pollutants, 15A NCAC 2D
.1206 Hospital, Medical and Infectious Waste Incinerators, and 40 CFR 62 Subpart HHH Federal Plan
Requirements for Hospital/Medical/Infectious Incinerators Constructed on or Before June 20, 1996
apply. The emissions test results are shown in the tables below in units of milligram per dry standard
cubic meter(mg/dscm), grains per dry standard cubic foot(gr/dscf), grains per one thousand dry standard
cubic foot(gr/103 dscf),parts per million by volume(ppmv), and percent(%) opacity. All concentrations
are corrected to 7%oxygen.
Emissions Test Results for ESO1 April 6, 2021
Pollutant Test Result Emission Limit Regulation Compliance
9.97 m /dscm 25 m .dscm
PM Yes
0.00436 r/dscf 0.011 r/dscf
HCl 0.0940 ppmv 6.6 ppmy Yes
0.0152 m /dscm 0.036 m /dscm
Pb 0.007 r/103 dscf 0.016 r/103 dscf 2D .1206 Yes
<0.00140 m .dscm 0.009 m /dscm
Cd <0.0006 r/103 dscf 0.0040 r/103 dscf Yes
<0.00203 m /dscm 0.018 m /dscm
Hg <0.0009 r/103 dscf 0.0079 r/103 dscf Yes
% opacity 0% 6% Yes
Mr. Ray Stewart
Page 2
DAQ Tracking No. 2021-078ST
Emissions Test Results for ES02 April 7, 2021
Pollutant Test Result Emission Limit Regulation Compliance
14.3 m /dscm 25 m /dscm
PM Yes
0.00623 r/dscf 0.011 r/dscf
HCl 1.74 ppmv 6.6 ppmv Yes
0.0167 m /dscm 0.036 m /dscm
Pb 0.007 r/l03 dscf 0.016 gr/103 dscf 2D .1206 Yes
<0.000737 m dscm 0.009 m /dscm
Cd <0.0003 r/103 dscf 0.0040 r/103 dscf Yes
<0.000896 m dscm 0.018 m /dscm
Hg <0.0004 r/103 dscf 0.0079 r/103 dscf Yes
%o acit 0% 6% Yes
2D .1100 limits the total combined emissions from both incinerators for Cd, HCl and Hg. The combined
emissions test results are shown in the following table.
Combined Emissions Test Results for ESO1 and ES02
Pollutant Combined Test Result Combined Emission Limit' Regulation Compliance
Cd <0.191 lb/ r 63.91 lb/yr
HCl 0.0376 lb/hr 2.2 lb/hr 2D .1100 Yes
Hg <0.00070 lb/day 3.821b/da
' lb/yr=pounds per year;lb/hr=pounds per hour;lb/day--pounds per day
ESO1 averaged 1711 lb/hr(92%of maximum) charge rate and ES02 averaged 1718 lb/hr(92%of
maximum) charge rate during testing and these charge rates are acceptable. The emissions test results
demonstrate compliance with the applicable regulations. If there are any questions regarding this review,
please contact me for clarification.