Loading...
HomeMy WebLinkAboutAQ_F_2100073_20210826_ST_ProtRvw �t„c STATE`u� ROY COOPER Governor ELIZABETH S.BISER Secretary rf$ ^P µ* MICHAEL ABRACZINSKAS NORTH CAROLINA Director Environmental Quality August 26, 2021 Anna Miller Manager Environmental, Health and Safety Regulator Marine,Inc. 187 Peanut Drive Edenton,NC 27932 Subject: Regulator Marine,Inc. Edenton, Chowan County,North Carolina Facility ID 21-00073, Air Permit No. 07132TI3,DAQ Tracking No. 2021-240ST Proposed Carbon Monoxide(CO)Emissions Testing of Diesel-Fired Peak Shaving Generator ES-14 by Integrity Air Monitoring, Inc. October 19, 2021 Dear Ms. Miller: Integrity Air Monitoring(Integrity)proposes EPA Method 3A for oxygen(02) and EPA Method 10 for CO emissions testing of generator ES-14. The proposed emissions testing is acceptable for demonstrating compliance with the applicable regulations. ES-14 is a diesel-fired peak shaving generator controlled by diesel oxidation catalyst CD-14. The generator is rated at 764 horsepower maximum capacity. 40 CFR 63 Subpart ZZZZ National Emissions Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines applies and specifies CO emissions shall be reduced by 70%or more using an oxidation catalyst or no more than 23parts per million by volume corrected to 15% oxygen(ppmvd@15%02). Permit condition 2.1.C.3 states the temperature of the catalyst inlet should be maintained at>450 OF and<1350 OF. The pressure drop across the catalyst should be maintained±2 inches of water at 100%load±10%from the pressure drop that was measured during the most recent performance test. Integrity proposes testing at the inlet and outlet of the catalyst with the differential pressure across the catalyst,temperatures, and engine output being recorded every 15 minutes. The CO and 02 measurements should be dry and the engine should be tested at f10%of maximum load. The proposed emissions testing is acceptable. Approval of the protocol does not exempt the tester from the minimum requirements of the methods. Deviation from the methods remains subject to approval by DAQ. If there are any questions regarding this review,please contact me at(919)707-8427 or Brent.Hall a,ncdenngov. Sincerely, wW W.MaU Brent W. Hall Special Projects Engineer Cc: Andrew Dickson, Integrity Betsy Huddleston,WARO IBEAM Documents-2100073 D E Q� North Carolina Department of Environmental Quality I Division of Air Quality 217 West Jones Street 1 1641 Mail Service Center I Raleigh,North Carolina 27699-1641 N09J I'>CA%OUNA 0"arhr*MorEnyGn uftIOLmlI\ 919.707.8400