HomeMy WebLinkAboutAQ_F_2000115_20210611_CMPL_InspRpt Zao®a - A(6
NORTH CAROLINA DIVISION OF Asheville Regional Office
AIR QUALITY Moog, Inc.
NC Facility ID 2000115
Inspection Report County/FIPS: Cherokee/039
Date: 06/14/2021
Facility Data Permit Data
Moog, Inc. Permit 07680/R06
1995 Hwy 141 Issued 6/4/2014
Murphy,NC 28906 Expires 5/31/2022
Lat: 35d 5.6640m Long: 83d 56.7840m Class/Status Small
SIC: 3621 /Motors And Generators Permit Status Active
NAICS: 335312/Motor and Generator Manufacturing Current Permit Application(s)None
Contact Data Program Applicability
Facility Contact Authorized Contact Technical Contact SIP
Danielle Loyd R Keaton Danielle Loyd MACT Part 63: Subpart 6H, Subpart 6W, Subpart
Environmental Health& General Manager Environmental Health& 6X,Subpart N
Safety Engineer (540)808-8876 Safety Engineer
(828)837-5115 (828)837-5115
Compliance Data
Comments:
Inspection Date 06/11/2021
Inspector's Name Steven Ensley
Inspector's Signature: Operating Status Operating
—� Compliance Status Compliance-inspection
Action Code FCE
Date of Signature: 4 /! Ll Z Inspection Result Compliance
Total Actual emissions in TONS/YEAR:
TSP S02 NOX VOC CO PM10 * HAP
2012 0.0300 --- --- 0.8800 --- 0.0200 34.81
2008 0.0500 --- --- 0.0090 --- 0.0500 8.90
* Highest HAP Emitted(in pounds)
Five Year Violation History:None
Date Letter Type Rule Violated Violation Resolution Date
Performed Stack Tests since last FCE:None
Date Test Results Test Method(s) Source(s)Tested
Directions: The plant is located on State Highway 141 in Peachtree. From US 74, at Marble,
turn left on 141 and travel approximately seven miles to Peachtree. The plant is on the right on
141.
Description: This facility manufactures avionics and other small motors and gauges.
On June 11, 20215 I met with facility contact Mike Murray to inspect the facility. Mr. Murray is
the assistant to Environmental contact Danielle Loyd who was not at the facility at the time.
Face covering was worn during the inspection as MOOG currently requires it for everyone inside
as a COVID 19 restriction. Mr. Murray explained that there had been no changes or
modifications to the facility since the last inspection.
Permitted Items
Emission Emission Source Control Control System
Source ID Description System ID Description
001 and 016 two water curtain-type paint spray booths used in a metal N/A N/A
(GACT) parts coating operation
GACT one nickel p007 lating line AN/A N/A
Oil Fonechromium anodizing operation(tank surface area of N/A N/A
(MACT) 1 .5 square feet)
012 one sodium dichromate passivating operation �N/A N/A
(GACT)
1. two water curtain-type paint spray booths (ID No. 001 and 016) used in a metal
parts coating operation;
VISIBLE EMISSIONS CONTROL REQUIREMENT -As required by 15A
NCAC 2D .0521 "Control of Visible Emissions," visible emissions from the
nickel plating line (ID No. 007) and the spray booth(ID No. 016), manufactured
after July 1, 1971, shall not be more than 20 percent opacity when averaged over
a six-minute period...
Observed but not in operation during inspection. 0%visible emissions.
2. one nickel plating line (ID No. 007);
VISIBLE EMISSIONS CONTROL REQUIREMENT - As required by 15A
NCAC 2D .0521 "Control of Visible Emissions," visible emissions from the
nickel plating line (ID No. 007) and the spray booth (ID No. 016), manufactured
after`July 1, 1971, shall not be more than 20 percent opacity when averaged over
a six-minute period.
This line operates infrequently as job demand requires.
Observed but not in operation during inspection. 0%visible emissions.
3. one chromium anodizing operation (ID No. 011);
a. MACT Emissions Limitations - During tank operation the surface tension of the
electroplating bath for the affected source shall not exceed:
t
Affected Source(s) .Pollutant Emission Limit(s)
(dynes/cm)
chromium anodizing operation,
eration
40
(ID No. 011)
Logbook records indicate surface tension measurements were well below the 40
dynes/cm limit.
b. VISIBLE EMISSIONS CONTROL REQUIREMENT - As required by 15A
NCAC 2D .0521 "Control of Visible Emissions," visible emissions from the spray
booth(ID No. 001) and the chromium anodizing operation (ID No. 011),
manufactured as of July 1, 1971, shall not be more than 40 percent opacity when
averaged over a six-minute period...
Observed but not in operation during inspection. 0%visible emissions.
4. One sodium dichromate passivating operation (ID No. 12):
Passivation removes the surface contamination created when stainless steel is
machined and fabricated. These contaminants can result in premature corrosion
that could ultimately damage the component. In addition to surface cleaning,
passivation forms a thin, transparent oxide coating that fights selective oxidation.
Observed but not in operation during inspection.
Fugitive Dust Control Requirement
No fugitive dust emissions were observed beyond the property boundary.
Work Practices Requirements
1. VOC-containing material was properly stored and no spills or waste rags were
observed. No parts washing was observed. All work practices requirements
appeared to be met.
2. The work practice standards for the stalagmometer recommended by the
manufacturer were being followed.
MACT
1. The operation and maintenance plan for the anodizing operation required to
comply with MACT monitoring and work practices was observed during a
previous inspection. This plan is maintained electronically on site.
2. The surface tension of the electroplating bath was checked at least every 4 hours
of operation to verify compliance with MACT Emissions Limitations requirement
that the tension shall not exceed 40 dynes/cm. In compliance.
GACT
a. Standard and Management Practices—the facility appeared to be following the
standard and management practices.
b. Recordkeeping Requirements- Ms. Loyd was not present during inspection to
provide access to records. Will observe at next inspection.
c. Reporting-Report received on 1/21/21 indicating compliance
CONTROL AND PROHIBITION OF ODOROUS EMISSIONS - As required by 15A
NCAC 2D .1806 "Control and Prohibition of Odorous Emissions" the Permittee shall not
operate the facility without implementing management practices or installing and
operating odor control equipment sufficient to prevent odorous emissions from the
facility from causing or contributing to objectionable odors beyond the facility's
boundary.
No objectionable odors were observed beyond the facility's boundary.
Exempted Activities
Source Exemption ,Sore of Source of Title V
Regulation ' TAPs? Pollutants?
1-008 - one zinc phosphate coating lineI G`� •0102 No Yes
P P g (c)(2)(E)(1)
I-014 - one bead blast operation(M3333
BlastnPeen) (vented inside, controlled by 2Q .0102
Q •L Dix i No No
bagfilter) (GACT 6X) O( )( )( )
I-015 - one bead blast operation (M3264
Silverado) (vented inside, controlled by 2Q .0102 No No I
bagfilter) (GACT 6X) (c)(1)(L)(ix)
11-0 16 - one rust preventer line 2Q .0102 No E No
f i
f
(c)(1)(L)(xii)
2Q .0102
I-017 - one air compressor heat evaporator ' E No Yes
(c)(2)(E)(i)
1. one zinc phosphate coating line (I-008) - Observed.
2. one bead blast operation (M3333 BlastnPeen) (vented inside, controlled by
bagfilter) (GACT 6X) I-014. - Observed
3. one bead blast operation (M3264 Silverado) (vented inside, controlled by
bagfilter) (GACT 6X) I-015. Observed
4. one rust preventer line I-016. Not observed.
5. one air compressor heat evaporator I017. Not observed.
5 Year Compliance History
A review of the 5 year compliance history revealed no compliance issues.
Compliance Statement:
Moog, Inc. appeared to be in compliance by inspection with permit No. 07680R06.