Loading...
HomeMy WebLinkAboutAQ_F_1800590_20210716_ST_RvwLtr_2021-146ST ROY COOPER srnrF� K,nv 10.my Governor ELIZABETH S.BISER Secretary _ �2 QUAM vry Y MICHAEL A.ABRACZINSKAS NORTH CAROLINA Director Environmental Quality July 16,2021 Mr.Matthew Cohn,President&CEO Substance Incorporated 3000 Frazier Drive Claremont,NC 28610 Subject: Volatile Organic Compound Destruction Efficiency Testing and Permanent Total Enclosure Testing of the Adhesive Coating Line(ID No. ES-1)Performed on April 28,2021 Substance Incorporated Claremont, Iredell County,North Carolina Facility ID No. 1800590 Air Permit No. 10649R00 Tracking No. 2021-146ST Dear Mr. Cohn: Volatile organic compound destruction efficiency testing and permanent total enclosure testing was performed on the adhesive coating line(ID No. ES-1)with associated regenerative thermal oxidizer(ID No. CD-1)at Substance Incorporated located in Claremont, Catawba County,North Carolina on April 28, 2021. The test was performed in accordance with air permit No. 10649R00, Specific Conditions and Limitations No. A.6.e. The Stationary Source Compliance Branch of the North Carolina Division of Air Quality has completed a review of the referenced test. It was determined that the testing is an acceptable demonstration of compliance. Please find enclosed a copy of the test review memorandum. If you have any questions with reference to this matter,please do not hesitate to contact Ms. Emily Supple or me at(704) 663-1699. Sincerely, Denim Wayx,3 Denise Hayes Environmental Engineer DFH: Enclosure c: MRO File https://ncconnect.sharepoint.com/sites/DAQ-MRO/Counties/CATAWBA/00590/STK LET_20210716.docx North Carolina Department of Environmental Quality I Division of Air Quality D_E Mooresville Regional Office 1 610 East Center Avenue,Suite 301 1 Mooresville,NC 28115 NORTH CAROLINA Deparhoent of Environmental Uaal\ r 704.663.1699 T 1 704.663.6040 F DIVISION OF AIR QUALrr Y Jaly 8,2021 MEMORANDUM To: Bruce Ingle,Mao -dk Regional Office Swen� From: Bret W-Hall.Stationary Source Complimee Branch(SSCB).BUR Subject: Substance,Inc. axemor,C= a county,Nor&Carolina Facility ID 15-0659 Q A,ir Pmmi t No-10649R00 VOC Deshuctiom Efficiem-y Testing for Adheswe Coating Line ES-1 P-fa—e3 by TRC EmaronmenEd on APril28.2021 DAQ Trackmg No-2021-1465T TRC E----tal,lne MKE)perfwmed EPA Method 204 for perorimmstotal enclosure RTE.)and EPA Metbad 25A far inlatile organic compmnL(VOC)at the inlet and outlet aFemissiom souse ES-1. The emismom test results dmnnndrata comphoute with the applicable regulatiams- Emission source ES-1 is m adhesive coating application fine with a nafiQal gas-fired curing m-m controlled by regenerative thermal oxidizer(RTO)CD-1. 40 CFR 60 Subpart RR Sods 4 PerfvrmvmcaforPrmsora Smsim-a YWwandLubsl Smurzras Coaang OpmaAdffs applies and limab VOC emissians to 0.20lfllogacams per kilogram of coating solid or requires a 9D%reduction of VOC emissions an a moodiily basis- 15A NCAC 2Q-0315,piraticY-nor Fadlirras and 15A VCAC 2Q.0317 Avmdfawe Cbnditevrm for 15A NCAC ZD.0530 Prenmtiorr 3 aQrrt Deter iararivrr also apply. The emisma is test reultr are shown in the table below- R---A Emissiao Pollotd� Inlet Ovdet Effic� Umif Rm,l'r'-0m C4mpliamce VOC 193.51bIr 1 0.953 Ib4u 49.0% 90% 60.SulopartRR Y� TRC performed an EPA Method 204 maluatim and determmed the enck=-e meets the iEquaements fo-r PTE The face imlanty thrwgh the natural draft opeamgs[NI]O)Ras 1689 a-tail cubic feet per minute (aef n). The average temperature for the three rm=in the RTO ww 1630 T and 768 pomp of VOC was ll-*PJd,d—ng teA�a TbE eMIS;aas test insult}dwmand.-&te compliance Vnth the applicable reffuhnons- If there are any questions regardiagthis renew,please canbrtme at{919{707-9427 ar Brmt.HalLunodeax wv- Cc: IHEAM Dooummar.-1800590