Loading...
HomeMy WebLinkAboutAQ_F_1800590_20210505_ST_STO-Rpt_2021-146ST NORTH CAROLINA DIVISION OF Mooresville Regional Office AIR QUALITY Substance Incorporated NC Facility ID 1800590 Stack Test Observation Report County/FIPS: Catawba/035 Date: 04/28/2021 Facility Data Compliance Data Substance Incorporated Observation Date 4/28/2021 3000 Frazier Drive Observer's Name Emily Supple Claremont,NC 28610 Operating Status Operating Lat: 35d 42.4487m Long: 81 d 9.4048m Action Code SIC: 2671 /Paper Coated And Laminated Packaging NAICS: 326112/Plastics Packaging Film and Sheet(including Laminated) Manufacturing Contact Data Permit Data Facility Contact Authorized Contact Technical Contact Permit 10649/R00 Kenny Testa Matthew Cohn Kenny Testa Issued 6/19/2020 President&CEO Expires 5/31/2028 (800)985-9485 (800)985-9485 (800)985-9485 Classification Synthetic Minor Permit Status Active Inspector's Signature: Em4 I Stapp& J95:x Comments:Virtual observation performed via Microsoft Teams due to COVID safety precautions. Date of Signature: 5/5/2021 Type Action: _Full Compliance _Partial Compliance _Complaint Other: Stack Test 2021-146ST Evaluation Evaluation/Reinspection Investigation Data Tracking: Date submitted for initial review 5/5/2021 _IBEAM WARNING/OB,NOD,NOV,NRE X IBEAM Document IBEAM Inspection,list date inspected _IBEAM LAT/LONG,Facility Locked IBEAM Inspection,list date draft is submitted _IBEAM LAT/LONG,Coordinates checked IBEAM Inspection,pollutants/programs checked IBEAM Complaint IBEAM Planning,Next Inspection Date 1. The facility conducted the initial performance test of the RTO as per NSPS Subpart RR. The testing was performed in accordance with Method 25A to determine the VOC destruction efficiency and overall performance of the RTO. 2. I observed the test virtually via Microsoft Teams meeting with Gleason Wilson,Director of Operations of Substance Incorporated, on April 28,2021. Mr. Wilson used the camera on his cell phone to show me the location of the stack test probes,the inlet and outlet VOC concentration readings, and the temperature of the RTO. The data I collected is shown in the table below. Substance Incorporated April 28,2021 Page 2 Run Time of Inlet VOC Outlet VOC Control Temperature of Observation Concentration Concentration Efficiency RTO (°F) (ppm) m 1 8:43AM 1,017 3.5 99.7 1,670 2 10:07AM 1,040 3.05 99.7 1,633 3 11:40AM 1,027 1.2 99.9 Did not Observe 3. The RTO operated with a set point temperature of 1,600 °F at the time of the stack test. The facility reported a total of 768 pounds of VOC containing solvent usage for the duration of the stack test. The testing company determined that the RTO could be considered a Permanent Total Enclosure. 4. Based on my observations,the test appears to have been performed within all applicable regulations. EJS: https://ncconnect.sharepoint.com/sites/DAQ-MRO/Counties/CATAWBA/00590/STK OBSERVED 20210428.docx