HomeMy WebLinkAboutAQ_F_1800590_20210505_ST_STO-Rpt_2021-146ST NORTH CAROLINA DIVISION OF Mooresville Regional Office
AIR QUALITY Substance Incorporated
NC Facility ID 1800590
Stack Test Observation Report County/FIPS: Catawba/035
Date: 04/28/2021
Facility Data Compliance Data
Substance Incorporated Observation Date 4/28/2021
3000 Frazier Drive Observer's Name Emily Supple
Claremont,NC 28610 Operating Status Operating
Lat: 35d 42.4487m Long: 81 d 9.4048m Action Code
SIC: 2671 /Paper Coated And Laminated Packaging
NAICS: 326112/Plastics Packaging Film and Sheet(including Laminated)
Manufacturing
Contact Data Permit Data
Facility Contact Authorized Contact Technical Contact Permit 10649/R00
Kenny Testa Matthew Cohn Kenny Testa Issued 6/19/2020
President&CEO Expires 5/31/2028
(800)985-9485 (800)985-9485 (800)985-9485 Classification Synthetic Minor
Permit Status Active
Inspector's Signature: Em4 I Stapp& J95:x Comments:Virtual observation performed via Microsoft Teams
due to COVID safety precautions.
Date of Signature: 5/5/2021
Type Action: _Full Compliance _Partial Compliance _Complaint Other: Stack Test 2021-146ST
Evaluation Evaluation/Reinspection Investigation
Data Tracking: Date submitted for initial review 5/5/2021 _IBEAM WARNING/OB,NOD,NOV,NRE
X IBEAM Document
IBEAM Inspection,list date inspected _IBEAM LAT/LONG,Facility Locked
IBEAM Inspection,list date draft is submitted _IBEAM LAT/LONG,Coordinates checked
IBEAM Inspection,pollutants/programs checked IBEAM Complaint
IBEAM Planning,Next Inspection Date
1. The facility conducted the initial performance test of the RTO as per NSPS Subpart RR. The
testing was performed in accordance with Method 25A to determine the VOC destruction
efficiency and overall performance of the RTO.
2. I observed the test virtually via Microsoft Teams meeting with Gleason Wilson,Director of
Operations of Substance Incorporated, on April 28,2021. Mr. Wilson used the camera on his cell
phone to show me the location of the stack test probes,the inlet and outlet VOC concentration
readings, and the temperature of the RTO. The data I collected is shown in the table below.
Substance Incorporated
April 28,2021
Page 2
Run Time of Inlet VOC Outlet VOC Control Temperature of
Observation Concentration Concentration Efficiency RTO (°F)
(ppm) m
1 8:43AM 1,017 3.5 99.7 1,670
2 10:07AM 1,040 3.05 99.7 1,633
3 11:40AM 1,027 1.2 99.9 Did not Observe
3. The RTO operated with a set point temperature of 1,600 °F at the time of the stack test. The
facility reported a total of 768 pounds of VOC containing solvent usage for the duration of the
stack test. The testing company determined that the RTO could be considered a Permanent Total
Enclosure.
4. Based on my observations,the test appears to have been performed within all applicable
regulations.
EJS:
https://ncconnect.sharepoint.com/sites/DAQ-MRO/Counties/CATAWBA/00590/STK OBSERVED 20210428.docx