HomeMy WebLinkAboutAQ_F_1900134_20220425_ST_RvwMemo (4) DIVISION OF AIR QUALITY
April 25, 2022
MEMORANDUM
To: Taylor Hartsfield, EIT, CPM, Raleigh Regional Office
From: Shannon Vogel, Stationary Source Compliance Branch
Subject: Duke Energy Progress LLC—Cape Fear STAR® Facility
Moncure, Chatham County, North Carolina
Facility ID 1900134, Permit No. 10583R01
Emissions Testing of ES-9 External Heat Exchanger
Performed January 26, 2021 by Grace Consulting, Inc.
Tracking No. 2021-327st
Grace Consulting performed EPA Method 5/202 total particulate matter (PM)testing of the
external heat exchanger (EHE) ES-9. The total PM emissions test results demonstrate
compliance with the applicable total PM emissions limit as discussed below.
Emissions Source ES-9 the external heat exchanger B with a 70 ton per hour nominal capacity.
Emissions from ES-9 are controlled by baghouse CD-9. 15A NCAC 2D .0515 Particulates From
Miscellaneous Industrial Processes applies to ES-9. The reported process rate averaged 34.8
tons per hour (tph). The 2D .0515 total PM emissions limit for this rate is 42.2 pounds per hour
(lb/hr). The test results are acceptable.
Pollutant Test Result Emissions Limit Standard Compliance
Filterable PM 0.53 Ib/hr --- --- ---
Condensible PM 0.92 Ib/hr --- --- ---
Total PM 1.45 Ib/hr 42.3 Ib/hr 2D .0515 Yes
Process Rate 34.8 tph --- --- ---
Compliance was demonstrated. If you have any questions or comments, please contact me at
shannon.vogel i or 919-707-8416.
cc: IBEAM Documents 1900134