HomeMy WebLinkAboutAQ_F_0700152_20220308_ST_RvwMemo (5) DIVISION OF AIR QUALITY March 8, 2022 MEMORANDUM To: Betsy Huddleston, Washington Regional Office t4 From: Shannon Vogel,Stationary Source Compliance Branch Subject: Food Lion Washington Store 144 and Store 2220 Washington, Beaufort County, North Carolina Facility ID 0700152, Permit Exempt Carbon Monoxide Emissions Testing of Diesel Peak Shaving Engines ES-1 and ES-2 Performed March 16, 2021 by Environmental Source Samplers Inc. (ESS) Tracking No. 2021-043st ES-1 Store 144 [1345 US Highway 264 East] CAT Model 3406 519hp(source description),S/N 1DZ6754(reported 400kw/575hp) Tracking No. 2021-177st ES-2 Store 2220 [851 Washington St] CAT Model 3406 519hp/350kW,S/N 1DZ06756 ESS performed EPA Method 3A for oxygen and EPA Method 10 for carbon monoxide (CO)emissions from the diesel peak shaving engines ES-1 (Store 144)and ES-2 (Store 2220).The emissions test results demonstrate compliance with the applicable regulations. 40 CFR 63 Subpart ZZZZ National Emissions Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines(RICE NESHAP) applies and limits CO emissions to 23 parts per million by volume dry corrected to 15%oxygen (ppmvd@15%02) OR requires at least 70% reduction of CO emissions.The facility chose to demonstrate compliance with the exit concentration limit. The test results and operating parameters are tabulated below. ES-1 Store 144 [1345 US Hwy 264 East] Emissions Test Results and Operating Parameters Pollutant/Parameter Test Results Emission Limit Regulation Compliance CO 15.66 ppmvd@15%02 23 ppmvd@15%02 63 Subpart ZZZZ Yes Power Output 145.8 kW (114-214 kW) Catalyst Inlet Temp. 635°F-717°F >A50°F and 51350°F 63 Subpart ZZZZ Yes Catalyst AP 1.23 in. H2O --- --- --- Install Date 2003 --- --- --- Post-Test Operating Hrs 3706 --- --- --- ES-2 Store 2220 [851 Washington Street] Emissions Test Results and Operating Parameters Pollutant/Parameter Test Results Emission Limit Regulation Compliance CO 19.85 ppmvd@15%02 23 ppmvd@15%02 63 Subpart ZZZZ Yes Power Output 145.5 kW (115-180 kW) Catalyst Inlet Temp. 575°F-675°F >_4507 and<_1350°F 63 Subpart ZZZZ Yes Catalyst AP 1.63 in. H2O --- --- --- Install Date 2003 --- --- --- Post-Test Operating Hrs 737 --- --- --- Betsy Huddleston Tracking Nos. 2021-043st and 2021-177st March 8, 2022 Page 2 63 Subpart ZZZZ states the engine shall be tested at the maximum rated electrical output±10%.The pressure drop (AP)across the catalyst shall be maintained within ±2 inches of water(in.1-12O)from the value established during the initial performance test.The catalyst inlet temperature shall be maintained >_4509F and:513509F. ES- 1 averaged 145.8 kW(42%of maximum output) and ES-2 averaged 145.5 kW(42%of maximum output) during testing. The results are acceptable for the tested operating ranges. Additional testing may be required to establish the catalyst AP and inlet temperature if the engines operate at higher rates in the future.The CO test results demonstrate compliance with 40 CFR 63 Subpart ZZZZ. If you have any questions regarding the results of this review, please contact me at(919)707-8416 or Shannon.Vogel@ncdenr.gov. cc: IBEAM Documents—0700152