Loading...
HomeMy WebLinkAboutAQ_F_1400092_20211213_CMPL_InspRpt (4) NORTH CAROLINA DIVISION OF Asheville Regional Office AIR QUALITY McCreary Modern, Inc. -Upholstery Plant NC Facility ID 1400092 Inspection Report County/FIPS: Caldwell/027 Date: 12/14/2021 Facility Data Permit Data McCreary Modern,Inc. -Upholstery Plant Permit 05207/R13 2978 Rocky Road Issued 8/9/2017 Lenoir,NC 28645 Expires 7/31/2025 Lat: 35d 52.0320m Long: 81 d 35.8140m Class/Status Small SIC: 2512/Upholstered Household Furniture Permit Status Active NAICS: 337121 /Upholstered Household Furniture Manufacturing Current Permit Application(s)None Contact Data Program Applicability Facility Contact Authorized Contact Technical Contact SIP Tyler Smith Rick Coffey Ryan Coulter Plant Manager President Director of Engineering (828)464-6465 (828)464-6465 828-464-6465 Compliance Data Comments: Inspection Date 12/13/2021 Inspector's Name Bob Graves Inspector's Signature: Operating Status Operating Compliance Status Compliance-inspection Action Code FCE Date of Signature: Inspection Result Compliance Total Actual emissions in TONSIYEAR: TSP S02 NOX VOC CO PM10 * HAP 2016 0.4900 --- --- 24.64 --- 0.0500 2521.00 2011 0.4800 --- --- 28.40 --- 0.0500 3494.00 * Highest HAP Emitted(in pounds) Five Year Violation History:None Date Letter Type Rule Violated Violation Resolution Date Performed Stack Tests since last FCE:None Date Test Results Test Method(s) Source(s)Tested 1) Location: McCreary Modern Inc. - Upholstery Plant is located at 2978 Rocky Road in Lenoir,NC. Caldwell County. Directions: From Morganton, take Hwy 18N to the Gamewell Community. The facility is on the right at the corner of Morganton Blvd(Hwy 18) and Rocky Road. 2) Description: McCreary Modern Inc. - Upholstery Plant is a furniture finishing plant. This facility is permitted under Air Permit No. 05207R13, effective from August 9, 2017, until July 1, 2025. Last compliance inspection conducted on December 9, 2020 by Bob Graves. Current throughputs: 2021 Employees: 73 Hours: 40 hrs./wk., 50 wks./yr. Permitted Sources are: Emission Emission Source Control Control System ` Source ID Description � System ID Description :one furniture finishing operation including: S13-1 through SB-8 eight dry filter-type spray booths N/A N/A T-1 and T-2 Jtwo wash-off tanks N/A N/A 3) Inspection: On December 13 2021, I, Bob Graves with the NCDAQ went to the facility and met with Chris Warren my facility contact (former Plant Manager), and Tyler Smith, the new Plant Manager. Based on my conversation with him, we discussed the following: a) Verified the contacts based on FACFINDER printout. Correct as listed. b) No changes have been made to the plant that would change the current air permit. 5) Inspection observations: a) Spray booths, SB-1 thru SB-8: inside spray booths not observed. I did not observe any visible emission emitting from the spray booth's outside stacks. Filters are usually changed weekly. Spray booths are labeled: Booth# Application Type 1 in operation Finish coating 2 not operating Sealer coating 3 not operating Sealer coating 4 not operating Glaze coating 5 in operation Lacquer coating 6 operating Lacquer coating 7 not operating Finish coating (not used often) 8 in operation Sealer/lacquer coating The facility was observed in operation. The spray booth area was clean and the spray booth filter were in very good condition. I did not observe any visible emissions coming from the outside spray booth stacks. b) Wash-off tanks: Not observed. One wash-off tank was onsite (the second tank has not been installed). This tank is kept outside and covered, and has not been used in three years. 6) Stipulation Review: A.2 2D.0512 —Particulate Control. In compliance. There are no wood working operations that vent to the atmosphere at this site. All painting operations are performed in dry-filter paint spray booths. A.4 2D.0521 —Visible Emissions. In compliance. I did not observe any visible emissions from the outside stacks. A.6 2D.0540—Fugitive Dust Control. In compliance. I did not observe any fugitive dust emissions during my inspection. A.7 2D.1806—Control and Prohibition of Odorous Emissions. In compliance. I did not detect any odors during my inspection. A.8 2Q. 0711 —TAP Emission Limit. Appears in compliance. Previous TAP emission rates have been well-below TPER emission limits and anticipated emission rates for these TAPs are expected to remain well-below applicable limits. A.10 2Q. 0803 —Exclusionary rule. Compliance Indicated. Last annual report indicated compliance. 7) Reporting requirements: Annual report for summarizing emissions of VOC and HAPs is required and must be submitted before March 1 annually. Last annual report was submitted on 02/28/2020 and indicated compliance. 8) 112R Status: Not subject to 112R reporting requirements. 9) Five Year Compliance History: No violations recorded in previous 5 years. 10) Comments and Compliance Statement: Based on review of records and visual observations, this facility appeared to be operating in compliance with the Air Quality standards and regulations at the time of this inspection.