Loading...
HomeMy WebLinkAboutAQ_F_0400009_20221115_EI_Apprd-EI This form is for Non-Title V facilities. If this facility is classified as Title V,please obtain and use the appropriate form Inventory Certification Form(Non-Title V) Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 These forms must be completed and returned even if the facility did not operate or emissions were zero The legally defined "Responsible Official" of record for your facility is Charles Horne This person or one that meets the definition below must sign this certification form. The official submitting the information must certify that he/she complies with the requirements as specified in Title I5A NCAC 2Q .03040)which define the responsible official as the following: 1. For corporations,by principal executive officer of at least the level of vice-president,or his duly authorized representative, if such representative is responsible for overall operationof the facility from which the emissions described in the permit application form originates 2. for partnership or limited partnership,by a general partner 3. for a sole proprietorship,by the proprietor 4. for municipal, state federal, or other public entity, by a principal executive officer, rankingelected official, or other duly authorized employee CERTIFICATION STATEMENT: (Important:Legaft Responsible Official,read and sign after all submissions are final.) I certify that I am the responsible official for this facility, as described above, and hereby certify that the information contained in this air emissions report, including attached calculations and documentation, is true, accurate and complete. (Subject to legal penalties of up to $25,000 per occurrence and possible imprisonment as outlined in G.S. § 143-215.3(a)(2)) Responsible Official's Signature Below (use blue ink): Date Signed: Printed Name: Charles Horne Signature: This form applies to Non Title V facilities. If this facility is classified asTitle V,please telephone your regional office Emission Inventory Contact at once for proper formsand classification. Email address of Responsible Official: chorne@hornwoodinc.com Information on this Form cannot be held confidential 1 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville Listing of Emission Sources and Control Devices on Permit. See instructions *ES ID on *ES Description *CS ID *CS Description *CD ID's Air Permit Natural gas/Ultra-low Sulfur No.2 B-03 fuel oil-fired boiler(22.65 mmBtu/hr maximum heat input) I-ES 11 Surface Finishing Operation Natural gas-fired therminol heater(15 I-Main-058 mmBtu/hr maximum heat input)(NSPS Subpart Dc) Natural gas/Ultra-low Sulfur No.2 Main-031 fuel oil-fired boiler(44.398 mmBtu/hr maximum heat input) Natural gas/Ultra-low Sulfur No.2 TH-01 fuel oil-fired therminol heater(9.06 mmBtu/hr maximum heat input) Textile tenter frame(1,500 lbs of cloth per hour maximum capacity) Tenter 1 consisting of the following: a)pad- CS-1 Condenser/Mist Eliminator CD-2 applied finishing station,and b) therminol(hot oil)heated oven. Textile tenter frame(2,000 lbs of cloth per hour maximum capacity) consisting of the following:a)pad- Tenter 2 applied finishing station,and b) CS-1 Condenser/Mist Eliminator CD-2 natural gas-fired four zone heated oven(7.2 million Btu per hour maximum heat input) Textile tenter frame(2,000 lbs of cloth per hour maximum capacity) Electrostatic Precipitator(2,367 sq.ft. Tenter 3 consisting of the following: a)pad- CS-2 collection surface area) CD-3 applied finishing station,and b) therminol(hot oil)heated oven Textile tenter frame(2,100 lbs of cloth per hour maximum capacity) consisting of the following:a)pad- Electrostatic Preci itator 2 367 s Tenter 4 applied finishing station,and b) CS-2 collection surface area) ( � ft. q CD-3 natural gas-fired six zone heated oven (6 million Btu per hour maximum heat input) 2 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville Emission Source & Operating Scenario List- See Instructions *ES Group ID *ES ID SOS ID *OS Description I-ES 11 6 Surface Finishing-PM Emissions exhausted to outdoor screen house. 7 Process Boilers Btu ratings of. 22.65mmBtu,9.06mmBtu, GR3 TH-01,B-03 Process Boilers,2 Steam Boilers and 2 8 Thermanol Boilers(Main 32- 15.7mmBtu, Main 31-44.4mmBtu,Id 0 1-9.06mmBtu, Id 03-22.65mmBtu Main-031 9 NSPS Process Boilers Btu ratings o£ 44.4mmBtu, 15.7mmmBtu I-Main-058 NONE NONE G-19 Tenter 1,Tenter 2 12 TF-1 and TF-2(process plus combustion emissions) G-20 Tenter 3,Tenter 4 13 TF-3 and TF-4(process plus combustion emissions) 3 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 1.Emission Source ID (from permit) I-ES 11 or Emission Source Group ID 2. Emission Source Description : Surface Finishing Operation 3. Operating Scenario ID/ OS - 6/Surface Finishing-PM Emissions exhausted to outdoor screen Description: house. 4. SCC Number/Description: 33000199/Miscellaneous ; Other Not Classified 5. Throughput/units in 2020: 275 TON/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 0 to Control Device or Stack): 8. Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) 9. Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm) Rectangle(L x W) (in 0.1 feet) Screen FUGITIVE (NO 1 72 Area= I Outdoor screen House STACK) house 4 Operating Scenario: OS - 6 Emission Source/Group ID: I-ES 11 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 8 ) Days per Week ( 7 ) Weeks per Year ( 50 ) 11. Typical Start & End Times For Operating Scenario: Start: 800 End: 1600 12. Seasonal Periods Percent Annual Throughput: Jan-Feb + Dec y March-Ma June-Aug. Sept.-Nov. o 2020 25% 2020 25% 2020 25% 2020 25/a 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code Factor Control (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Emission EF Pollutant Criteria (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 TSP TSP 0.28 02 PM10 PM10 0.28 02 PM2.5 PM2.5 0.28 02 Emission HAP/TAP CAS Emissions Estimation Control Emission EF Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2020 5 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 1.Emission Source ID (from permit) Group GR3 Consisting of TH-01, B-03 or Emission Source Group ID 2. Emission Source Description : Non-NSPS Process Boilers 3. Operating Scenario ID/ OS - 7/Process Boilers Btu ratings of: 22.65mmBtu, 9.06mmBtu, Description: 4. SCC Number/Description: 10200602 /Natural Gas ; 10-100 Million Btu/hr 5. Throughput/units in 2020: 14.26 E6FT3/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) 0.5 0.1 140000 Btu/gallon (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 0 to Control Device or Stack): 8. Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) 9. Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm) Rectangle(L x W) (in 0.1 feet) ERP-01 VERTICAL 35 3.1 400 35.5 16076.55 Boiler Stacks (Rep) STACK 6 Operating Scenario: OS - 7 Emission Source/Group ID: GR3 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 5 ) Weeks per Year ( 51 ) 11. Typical Start & End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb + Dec y March-Ma June-Aug. Sept.-Nov. o 2020 25% 2020 25% 2020 25% 2020 25/a 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code Factor Control (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Emission EF Pollutant Criteria (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 NOx NOx 0.71 09 VOC VOC 0.04 09 Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code Efficiency ) Factor Control (Pounds/Year) (Net after all controls (See Instructions) 2020 Formaldehyde 50-00-0 1.07 09 Hexane, n- 110-54-3 25.7 09 7 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 1.Emission Source ID (from permit) Group GR3 Consisting of TH-01, B-03 or Emission Source Group ID 2. Emission Source Description : Non-NSPS Process Boilers 3. Operating Scenario ID/ OS - 8/Process Boilers, 2 Steam Boilers and 2 Thermanol Boilers (Main 32- Description: 15.7mmBtu, Main 31- 44.4mmBtu, Id 01-9.06mmBtu, Id 03-22.65mmBtu 4. SCC Number/Description: 10200501 /Distillate Oil (No. 1 & 2) ; Grades 1 and 2 Oil 5. Throughput/units in 2020: 438 GAL/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) 0.5 0.1 140000 Btu/gallon (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 0 to Control Device or Stack): 8. Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) 9. Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm) Rectangle(L x W) (in 0.1 feet) ERP-01 VERTICAL 35 3.1 400 35.5 16076.55 Boiler Stacks (Rep) STACK 8 Operating Scenario: OS - 8 Emission Source/Group ID: GR3 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 ) 11. Typical Start & End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb + Dec y March-Ma June-Aug. Sept.-Nov. o 2020 25% 2020 25% 2020 25% 2020 25/a 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code Factor Control (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Emission EF Pollutant Criteria (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 NOx NOx 0.01 08 S02 S02 0.02 08 Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2020 9 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 1.Emission Source ID (from permit) Main-031 or Emission Source Group ID 2. Emission Source Description : NSPS Boilers 3. Operating Scenario ID/ OS - 9/NSPS Process Boilers Btu ratings of. 44.4mmBtu, 15.7mmmBtu Description: 4. SCC Number/Description: 10200602 /Natural Gas ; 10-100 Million Btu/hr 5. Throughput/units in 2020: 57.1 E6FT3/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) 0.5 0.1 140000 Btu/CF (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 0 to Control Device or Stack): 8. Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) 9. Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm) Rectangle(L x W) (in 0.1 feet) ERP-01 VERTICAL 35 3.1 400 35.5 16076.55 Boiler Stacks (Rep) STACK 10 Operating Scenario: OS - 9 Emission Source/Group ID: Main-031 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 5 ) Weeks per Year ( 51 ) 11. Typical Start& End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb +Dec y March-Ma June-Aug. Sept.-Nov. ° 2020 25% 2020 25% 2020 25% 2020 25/o 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code ( Factor Control (Tons/Year) (See Instructions) all controls) 2020 Emissions- Emission Criteria pollutant Criteria Control Emission EF (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 CO CO 2.4 09 NOx NOx 2.86 09 TSP TSP 0.01 09 PM10 PM10 0.01 09 PM2.5 PM2.5 0.01 09 S02 S02 0.02 09 VOC VOC 0.16 09 Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In alphabetical order) (see instructions) HAP/TAPS Efficiency Factor Control (Pounds/Year) Method Code (Net after all controls) (See Instructions) 2020 Formaldehyde 50-00-0 4.28 09 Hexane, n- 110-54-3 103 09 11 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 1.Emission Source ID (from permit) Group G-19 Consisting of Tenter 1, Tenter 2 or Emission Source Group ID 2. Emission Source Description : TF I and TF 2 3. Operating Scenario ID/ OS - 12/TF-1 and TF-2 (process plus combustion emissions) Description: 4. SCC Number/Description: 33000104/Miscellaneous ; Tenter Frames: Heat Setting 5. Throughput/units in 2020: 1346.7 TON/yr (e.g.production or fuel use): 6. Fuel Information %sulfur %Ash Heat content (If fuel is used) (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 100 to Control Device or Stack): 8. Control Device Information Order CS-ID CD ID Control Device Description (as listed in permit) 1 CS-1 CD-2 Condenser/Mist Eliminator 9. Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm) Rectangle(L x W) (in 0.1 feet) VERTICAL Vent stack for ERP-3 STACK 39.3 2.29 400 7.1 1754.56 Natural gas Tenter Frames 12 Operating Scenario: OS - 12 Emission Source/Group ID: G-19 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 5 ) Weeks per Year ( 50 ) 11. Typical Start& End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb +Dec y March-Ma June-Aug. Sept.-Nov. ° 2020 25% 2020 25% 2020 25% 2020 25/o 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code ( Factor Control (Tons/Year) (See Instructions) all controls) 2020 Emissions- Emission Criteria pollutant Criteria Control Emission EF (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 CO CO 0.26 08 90 NOx NOx 0.31 08 90 TSP TSP 2.81 24 90 PM10 PM10 2.81 24 90 PM2.5 PM2.5 2.25 24 90 S02 S02 08 90 VOC VOC 1.1 03 90 Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In alphabetical order) (see instructions) HAP/TAPS Efficiency Factor Control (Pounds/Year) Method Code (Net after all controls) (See Instructions) 2020 Acetic acid 64-19-7 45 08 90 Cumene 98-82-8 27 08 90 Formaldehyde 50-00-0 4.03 08 90 Methanol(methyl alcohol) 67-56-1 10.08 08 90 Xylene (mixed isomers) 1330-20-7 54 08 90 13 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 1.Emission Source ID (from permit) Group G-20 Consisting of Tenter 3, Tenter 4 or Emission Source Group ID 2. Emission Source Description : TF-3 and TF-4 3. Operating Scenario ID/ OS - 13/TF-3 and TF-4 (process plus combustion emissions) Description: 4. SCC Number/Description: 33000104/Miscellaneous ; Tenter Frames: Heat Setting 5. Throughput/units in 2020: 1346.7 TON/yr (e.g.production or fuel use): 6. Fuel Information %sulfur %Ash Heat content (If fuel is used) (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 100 to Control Device or Stack): 8. Control Device Information Order CS-ID CD ID Control Device Description (as listed in permit) I CS-2 CD-3 Electrostatic Precipitator(2,367 sq.ft. collection surface area) 9. Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm) Rectangle(L x W) (in 0.1 feet) VERTICAL Vent stack for ERP-3 STACK 39.3 2.29 400 7.1 1754.56 Natural gas Tenter Frames 14 Operating Scenario: OS - 13 Emission Source/Group ID: G-20 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 5 ) Weeks per Year ( 50 ) 11. Typical Start& End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb +Dec y March-Ma June-Aug. Sept.-Nov. ° 2020 25% 2020 25% 2020 25% 2020 25/o 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code ( Factor Control (Tons/Year) (See Instructions) all controls) 2020 Emissions- Emission Criteria pollutant Criteria Control Emission EF (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 CO CO 0.26 08 90 NOx NOx 0.31 08 90 TSP TSP 2.81 24 90 PM10 PM10 2.81 24 90 PM2.5 PM2.5 2.25 24 90 S02 S02 08 90 VOC VOC 1.1 03 90 Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In alphabetical order) (see instructions) HAP/TAPS Efficiency Factor Control (Pounds/Year) Method Code (Net after all controls) (See Instructions) 2020 Acetic acid 64-19-7 45 08 90 Cumene 98-82-8 27 08 90 Formaldehyde 50-00-0 4.03 08 90 Methanol(methyl alcohol) 67-56-1 10.08 08 90 Xylene (mixed isomers) 1330-20-7 54 08 90 15 Facility Total CY 2020 Emissions Summary Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 Record Facility-Wide Totals From all Permitted and Non-Permitted Air Pollutant Emission Sources Green house Gases Pollutants(GHG) Actual Emissions(Tons/Year) Pollutant I CAS 12020 12013 %Change Criteria Pollutants Actual Emissions(Tons/Year) Pollutant CAS 2020 2013 %Change CO CO 2.92 5.32 -45.11278% NOx NOx 4.2 6.35 -33.85827% PM(TSP) TSP 5.91 8.97 -34.113716% PM 10 PM 10 5.91 8.97 -34.113716% PM2.5 PM2.5 4.79 7.25 -33.931034% S02 IS02 1.04 .05 -20.000002% VOC I VOC 12.4 10.3 -76.69903% Hazardous Air Pollutants(HAPS) and/or Toxic Air Pollutants(TAPs) Actual Emissions(Pounds/Year) Pollutant CAS 2020 2013 %Change Acetic acid 64-19-7 90 262 -65.64886% Cumene 98-82-8 54 Not reported N/A Formaldehyde 50-00-0 13.41 26.61 -49.605415% Hexane,n- 110-54-3 128.7 194.6 -33.86434% Methanol(methyl alcohol) 67-56-1 20.16 18.88 6.7796645% Xylene(mixed isomers) 1330-20-7 1108 Not reported I N/A 16 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville DAQ Internal Comments: 2/4/22 Data sent back due to phone call from Dale Kelly informing me that he had used some of the data from the wrong year. 4/11/2022 Reduction in the facility's emissions is due to production being cut down to nearly 1/4th of what it was in 2013. 17 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville Comments From Reviewer: 3/29/2022 - n en .rntingScenario Comments, OS8: No DAQ comments provided 3/29/2022 - Operating.rating Scenario Comments OS11: No DAQ comments provided 3/29/2022 - Operating Scenario (comments OS6: No DAQ comments provided 3/29/2022 - Operating Scenario (comments OS7: No DAQ comments provided 3/29/2022 - Operating Scenario (comments 0S10: No DAQ comments provided 3/29/2022 - Operating Scenario (comments OS5: No DAQ comments provided 3/29/2022 - Operating Scenario (comments OS9: No DAQ comments provided 18 Updated COR Date Submitted: 11/15/2022 09:17:16 Facility Name: Hornwood Inc Facility ID : 0400009 766 Hailey's Ferry Road Permit : 04888 Lilesville,NC 28091 County : Anson DAQ Region : Fayetteville AERO Comments From Facility: 3/29/2022 - Control Device Comments 1. CD CD-1 : CD-1 has been replaced with CD-3. CD-1 not in service. 3/29/2022 - Fmission Rnnree Comm rots, 1. ES I-Main-058 : Emission data was included with NSPS Boilers. In 2013 NSPS boilers was Main-031 and 2. Main-032. Main-032 was replaced by Main-058. Was advised to select "Source did not operate" and note 3. change. 19