Loading...
HomeMy WebLinkAboutAQ_F_0100010_20221026_EI_Apprd-EI Inventory Certification Form(Title V) Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2021 These forms must be completed and returned even if the facility did not operate or emissions were zero The legally defined "Responsible Official" of record for your facility is Kirk Yarbrough This person or one that meets the definition below must sign this certification form. The official submitting the information must certify that he/she complies with the requirements as specified in Title I5A NCAC 2Q.0520(b)which references and follows the federal definition. 40 CFR Part 70.2 definesa responsible as meaning one of the following: 1. For a corporation: a president, secretary, treasurer, or vice-president of the corporation in chargeof a principal business function, or any other person who performs similar policy or decision makingfunctions for the overall operation of one or more manufacturing,production, or operatingfacilities applying for a or subject to a permit and either the facilities employ more than 250 persons or have gross annual sales or expenditures exceeding$25 million(in second quarter 1980 dollars); orthe delegation of authority to such representatives is approved in advance by the permittingauthority; 2. For partnership or sole propietorship; a general partner or the proprietor,respectively; 3. for a muncipality, state, federal, or other public agency includes the chief executive officerhaving responsibility for the overall operations of a principal geographic unit of the a enc e. ., a Regional Administrator of EPA). CERTIFICATION STATEMENT: (Important:Legally Responsible Official,read and sign after all submissions are final.) I certify that I am the responsible official for this facility, as described above, and hereby certify that the information contained in this air emissions report, including attached calculations and documentation, is true, accurate and complete. (Subject to legal penalties of up to $25,000 per occurrence and possible imprisonment as outlined in G.S. § 143-215.3(a)(2)) Responsible Official's Signature Below (use blue ink): Date Signed: Printed Name: Kirk Yarbrough Signature: This form applies to Title V facilities. If this facility is not classified asTitle V,please telephone your regional office Emission Inventory Contact at once for proper forms. Email address of Responsible Official: Kirk.Yarbrough@stericycle.com Information on this Form cannot be held confidential 1 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem Listing of Emission Sources and Control Devices on Permit. See instructions *ES ID on *ES Description *CS ID *CS Description *CD ID's Air Permit diesel-fired emergency generator EG1 (500 kilowatts) [MACT ZZZZ;NSPS IIII] dual chamber hospital,medical and infectious waste incinerator(HMIWI) firing natural gas(4.6 million Btu/hr Quench Column,Packed bed gaseous CDO1,CD02, ESO1 primary chamber burner and 6.0 CS-1 adsorber,Venturi Scrubber CD03 million Btu/hr secondary chamber burner) dual chamber hospital,medical and infectious waste incinerator(HMIWI) firing natural gas(4.6 million Btu/hr Quench Column,Packed bed gasous adsorber, ES02.1,CD04, ES02 primary chamber burner and 6.0 CS-2 Venturi Scrubber ES02.3 million Btu/hr secondary chamber burner) I-AMM Facility-wide storage of 19%aqueous ammonia I-CT-1 cooling tower(55,200 gallons per hour water recirculation rate) I-CT-2 cooling tower(55,200 gallons per hour water recirculation rate) 2 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem Emission Source & Operating Scenario List- See Instructions *ES Group ID *ES ID SOS ID *OS Description One twin chamber hospital,medical, infectious waste incinerator(HMIWI) 2 (with a 4.6 million Btu per hour primary ES01 chamber burner and 6.0 million Btu per hour secondary chamber burner) Auxilliary natural gas fired on demand to 6 maintain correct incinerator chamber temperatures. One twin chamber hospital,medical, infectious waste incinerator(HMIWI) 3 (with a 4.6 million Btu per hour primary ES02 chamber burner and 6.0 million Btu per hour secondary chamber burner). Auxilliary natural gas fired on demand to 7 maintain the correct incinerator cchamber temperatures. EG1 1 one diesel-fired emergency generator(395 kilowatts,ID No.EG1) G-9 I-CT-1,I-CT-2 4 Cooling Towers I-AMM NONE NONE 3 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2021 1.Emission Source ID (from permit) ES01 or Emission Source Group ID 2. Emission Source Description : dual chamber hospital, medical and infectious waste incinerator(HMIWI) firing natural gas (4.6 million Btu/hr primary chamber burner and 6.0 million Btu/hr secondary chamber burner) 3. Operating Scenario ID/ OS - 2/One twin chamber hospital, medical, infectious waste incinerator Description: (HMIWI) (with a 4.6 million Btu per hour primary chamber burner and 6.0 million Btu per hour secondary chamber burner) 4. SCC Number/Description: 50200101 /Incineration ; Multiple Chamber 5. Throughput/units in 2021: 5874 TON/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 100 to Control Device or Stack): 8. Control Device Information Order CS-ID CD ID Control Device Description (as listed in permit) 1 CS-1 CDO 1 one packed bed scrubber and associated quench column 2 CS-1 CD02 one packed bed scrubber and associated quench column 3 CS-1 CD03 venturi scrubber equipped with a mist eliminator 9. Emission Release Point (ERP) Information: (Sources vented to more than one EPP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/see) Rate(Acfm) Rectangle(L x W) (in 0.1 feet) ES-01 VERTICAL 82.4 2.5 180 41.05 12090.21 MWI-01 STACK 4 Operating Scenario: OS - 2 Emission Source/Group ID: ES01 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2021) Hours per Day ( 23 ) Days per Week ( 6 ) Weeks per Year ( 52 ) 11. Typical Start & End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb + Dec y March-Ma June-Aug. Sept.-Nov. o 2021 25% 2021 25% 2021 25% 2021 25/a 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code Factor Control (Tons/Year) (See Instructions) all controls) 2021 Carbon Dioxide (CO2) 124389 7610.1194 04 0 2591.12 Criteria Emissions- Emission Control Emission EF Pollutant Criteria (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2021 CO CO 0.08 04 0 0.0269 AFTER NOx NOx 12.9 04 0 4.3932 AFTER TSP TSP 0.28 04 95 0.0964 AFTER PM10 PM10 0.28 04 95 0.0964 AFTER PM2.5 PM2.5 0.28 04 95 0.0964 AFTER S02 S02 0.16 04 95 0.0543 AFTER VOC VOC 0.41 08 0 0.14 AFTER Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2021 Arsenic Unlisted Compounds - Specify ASC-Other 0.02144 04 95 0.00000365 AFTER Compound (Component of ASC) Beryllium Unlisted Compounds - Specify BEC-Other 0.02273 04 95 0.00000387 AFTER Compound (Component o BEC) Cadmium Unlisted Compounds - Specify CDC- 0.0793 04 95 0.0000135 AFTER Compound (Component of Other CDC) Chlorine 7782-50-5 2.57869 04 95 0.000439 AFTER 5 Chromium (VI) Non- Specific Unlisted NSCR6- Compounds - Specify Other 0.00846 04 95 0.00000144 AFTER Compound (Component of NSCR6 & CRC) Fluorides (sum of all fluoride compounds as 16984-48-8 3.92383 04 95 0.000668 AFTER mass of F ion) Hydrogen chloride 7647-01-0 8.69352 04 95 0.00148 AFTER (hydrochloric acid) Hydrogen fluoride (hydrofluoric acid as mass 7664-39-3 3.92383 04 95 0.000668 AFTER of HF) (Component of 16984488/Fluorides) Lead Unlisted Compounds - Specify Compound PBC-Other 0.85302 04 95 0.00014522321 021 AFTER (Component of PBC) Manganese Unlisted Compounds - Specify MNC- 0.58035 04 95 0.0000988 AFTER Compound (Component of Other MNC) Mercury Unlisted Compounds - Specify HGC- 0.00001964 Compound (Component of Other 0.11541 04 95 7455 AFTER HGC) Nickel Unlisted Compounds (Component NIC-Other 1.09844 04 95 0.000187 AFTER of NIC - Specify) 6 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2021 1.Emission Source ID (from permit) ES01 or Emission Source Group ID 2. Emission Source Description : dual chamber hospital, medical and infectious waste incinerator(HMIWI) firing natural gas (4.6 million Btu/hr primary chamber burner and 6.0 million Btu/hr secondary chamber burner) 3. Operating Scenario ID/ OS - 6/Auxilliary natural gas fired on demand to maintain correct incinerator Description: chamber temperatures. 4. SCC Number/Description: 50200504/Incineration: Special Purpose ; Medical Waste Incinerator, unspecified type (use 502005-01, -02, -03) 5. Throughput/units in 2021: 6.73 E6FT3/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 100 to Control Device or Stack): 8. Control Device Information Order CS-ID CD ID Control Device Description (as listed in permit) 1 CS-1 CDO 1 one packed bed scrubber and associated quench column 2 CS-1 CD02 one packed bed scrubber and associated quench column 3 CS-1 CD03 venturi scrubber equipped with a mist eliminator 9. Emission Release Point (ERP) Information: (Sources vented to more than one EPP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/see) Rate(Acfm) Rectangle(L x W) (in 0.1 feet) ES-01 VERTICAL 82.4 2.5 180 41.05 12090.21 MWI-01 STACK 7 Operating Scenario: OS - 6 Emission Source/Group ID: ES01 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2021) Hours per Day ( 23 ) Days per Week ( 6 ) Weeks per Year ( 52 ) 11. Typical Start & End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb + Dec y March-Ma June-Aug. Sept.-Nov. o 2021 29% 2021 32% 2021 20% 2021 19/o 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code Factor Control (Tons/Year) (See Instructions) all controls) 2021 Carbon Dioxide (CO2) 124389 390.5419 03 0 116060 Criteria Emissions- Emission Control Emission EF Pollutant Criteria (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2021 CO CO 0.28 08 0 84 AFTER NOx NOx 0.34 08 0 100 AFTER TSP TSP 0.03 08 99 7.6 AFTER PM10 PM10 0.03 08 99 7.6 AFTER PM2.5 PM2.5 0.03 08 99 7.6 AFTER VOC VOC 0.02 08 0 5.5 AFTER Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2021 Ammonia (as NH3) 7664-41-7 21.536 08 99 3.2 AFTER Formaldehyde 50-00-0 0.50475 08 99 0.075 AFTER Hexane, n- 110-54-3 12.114 08 99 1.8 AFTER 8 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2021 1.Emission Source ID (from permit) ES02 or Emission Source Group ID 2. Emission Source Description : dual chamber hospital, medical and infectious waste incinerator(HMIWI) firing natural gas (4.6 million Btu/hr primary chamber burner and 6.0 million Btu/hr secondary chamber burner) 3. Operating Scenario ID/ OS - 3/One twin chamber hospital, medical, infectious waste incinerator Description: (HMIWI) (with a 4.6 million Btu per hour primary chamber burner and 6.0 million Btu per hour secondary chamber burner). 4. SCC Number/Description: 50200101 /Incineration ; Multiple Chamber 5. Throughput/units in 2021: 5781 TON/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 100 to Control Device or Stack): 8. Control Device Information Order CS-ID CD ID Control Device Description (as listed in permit) 1 CS-2 ES02.1 Quench Column 2 CS-2 CD04 venturi scrubber equipped with a mist eliminator 3 CS-2 ES02.3 Venturi Scrubber 9. Emission Release Point (ERP) Information: (Sources vented to more than one EPP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/see) Rate(Acfm) Rectangle(L x W) (in 0.1 feet) ES-02 VERTICAL 82.4 2.5 180 42 12370.02 MWI-02 STACK 9 Operating Scenario: OS - 3 Emission Source/Group ID: ES02 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2021) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 41 ) 11. Typical Start & End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb + Dec y March-Ma June-Aug. Sept.-Nov. o 2021 25% 2021 25% 2021 25% 2021 25/a 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code Factor Control (Tons/Year) (See Instructions) all controls) 2021 Carbon Dioxide (CO2) 124389 8818.3663 04 0 3050.81 Criteria Emissions- Emission Control Emission EF Pollutant Criteria (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2021 CO CO 0.06 04 0 0.0208 AFTER NOx NOx 10.96 04 0 3.7904 AFTER TSP TSP 0.7 04 95 0.2437 AFTER PM10 PM10 0.7 04 95 0.2437 AFTER PM2.5 PM2.5 0.7 04 95 0.2437 AFTER S02 S02 0.15 04 95 0.0523 AFTER VOC VOC 0.4 04 0 0.14 AFTER Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2021 Arsenic Unlisted Compounds - Specify ASC-Other 0.06417 04 95 0.0000111 AFTER Compound (Component of ASC) Beryllium Unlisted Compounds - Specify BEC-Other 0.01283 04 95 0.00000222 AFTER Compound (Component o BEC) Cadmium Unlisted Compounds - Specify CDC- 0.07284 04 95 0.0000126 AFTER Compound (Component of Other CDC) Chlorine 7782-50-5 4.94854 04 95 0.000856 AFTER 10 Chromium (VI) Non- Specific Unlisted NSCR6- Compounds - Specify Other 0.02601 04 95 0.0000045 AFTER Compound (Component of NSCR6 & CRC) Fluorides (sum of all fluoride compounds as 16984-48-8 4.21435 04 95 0.000729 AFTER mass of F ion) Hydrogen chloride 7647-01-0 247.70241 04 95 0.04284767 AFTER (hydrochloric acid) 4633 Hydrogen fluoride (hydrofluoric acid as mass 7664-39-3 4.21435 04 95 0.000729 AFTER of HF) (Component of 16984488/Fluorides) Lead Unlisted Compounds - Specify Compound PBC-Other 1.64681 04 95 0.00028486 AFTER (Component of PBC) 6408 Manganese Unlisted Compounds - Specify MNC- 0.17979 04 95 0.0000311 AFTER Compound (Component of Other MNC) Mercury Unlisted Compounds - Specify HGC- 0.00001530 Compound (Component of Other 0.08847 04 95 2741 AFTER HGC) Nickel Unlisted Compounds (Component NIC-Other 0.42548 04 95 0.0000736 AFTER of NIC - Specify) Tetrachlorodibenzo-p- dioxin, 2,3,7,8- 1746-01-6 0 04 50 4E-12 AFTER (Component of CLDC & 83329/POMTV) 11 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2021 1.Emission Source ID (from permit) ES02 or Emission Source Group ID 2. Emission Source Description : dual chamber hospital, medical and infectious waste incinerator(HMIWI) firing natural gas (4.6 million Btu/hr primary chamber burner and 6.0 million Btu/hr secondary chamber burner) 3. Operating Scenario ID/ OS - 7/Auxilliary natural gas fired on demand to maintain the correct Description: incinerator cchamber temperatures. 4. SCC Number/Description: 50200504/Incineration: Special Purpose ; Medical Waste Incinerator, unspecified type (use 502005-01, -02, -03) 5. Throughput/units in 2021: 6.39 E6FT3/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 100 to Control Device or Stack): 8. Control Device Information Order CS-ID CD ID Control Device Description (as listed in permit) 1 CS-2 ES02.1 Quench Column 2 CS-2 CD04 venturi scrubber equipped with a mist eliminator 3 CS-2 ES02.3 Venturi Scrubber 9. Emission Release Point (ERP) Information: (Sources vented to more than one EPP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft lF) (Feet/see) Rate Acfm Rectangle(L x W) ( ) (in 0.1 feet) ES-02 VERTICAL 82.4 2.5 180 42 12370.02 MWI-02 STACK 12 Operating Scenario: OS - 7 Emission Source/Group ID: ES02 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2021) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 41 ) 11. Typical Start & End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb + Dec y March-Ma June-Aug. Sept.-Nov. o 2021 25% 2021 25% 2021 25% 2021 25/a 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code Factor Control (Tons/Year) (See Instructions) all controls) 2021 Carbon Dioxide (CO2) 124389 370.8117 03 0 116060 Criteria Emissions- Emission Control Emission EF Pollutant Criteria (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2021 CO CO 0.27 08 0 84 AFTER NOx NOx 0.32 08 0 100 AFTER TSP TSP 0.02 08 99 7.6 AFTER PM10 PM10 0.02 08 99 7.6 AFTER PM2.5 PM2.5 0.02 08 99 7.6 AFTER S02 S02 0 08 90 0.6 AFTER VOC VOC 0.02 08 0 5.5 AFTER Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2021 Ammonia (as NH3) 7664-41-7 20.448 08 99 3.2 AFTER Formaldehyde 50-00-0 0.47925 08 99 0.075 AFTER Hexane, n- 110-54-3 11.502 08 99 1.8 AFTER 13 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2021 1.Emission Source ID (from permit) EG1 or Emission Source Group ID 2. Emission Source Description : diesel-fired emergency generator(500 kilowatts) [MACT ZZZZ; NSPS IIII] 3. Operating Scenario ID/ OS - 1/one diesel-fired emergency generator(395 kilowatts, ID No. EG1) Description: 4. SCC Number/Description: 20100105 /Distillate Oil (Diesel) ; Reciprocating: Crankcase Blowby 5. Throughput/units in 2021: 15831.8 HP-HR/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) 0.0015 (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 0 to Control Device or Stack): 8. Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) 9. Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm) Rectangle(L x W) (in 0.1 feet) 03 HORIZONTAL 10 0.7 400 1 23.09 Horizontal STACK 14 Operating Scenario: OS - 1 Emission Source/Group ID: EG1 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2021) Hours per Day ( 1 ) Days per Week ( 1 ) Weeks per Year ( 30 ) 11. Typical Start & End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb + Dec y March-Ma June-Aug. Sept.-Nov. o 2021 25% 2021 25% 2021 25% 2021 25/a 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code Factor Control (Tons/Year) (See Instructions) all controls) 2021 Carbon Dioxide (CO2) 124389 165489.8034 08 20906 Criteria Emissions- Emission Control Emission EF Pollutant Criteria (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2021 CO CO 0.05 10 NOx NOx 0.05 10 S02 S02 0.02 10 Emission HAP/TAP CAS Emissions Estimation Control Emission EF Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2021 15 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2021 1.Emission Source ID (from permit) Group G-9 Consisting of I-CT-1, I-CT-2 or Emission Source Group ID 2. Emission Source Description : Cooling Towers 3. Operating Scenario ID/ OS - 4/Cooling Towers Description: 4. SCC Number/Description: 31299999/Miscellaneous Machinery ; Other Not Classified 5. Throughput/units in 2021: 771309 E3GAL/yr (e.g.production or fuel use): 6. Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) 7. Capture Efficiency (%of Emissions from this Process Vented 0 to Control Device or Stack): 8. Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) 9. Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm) Rectangle(L x W) (in 0.1 feet) CT FUGITIVE (NO 1 72 Area= 1 Cooling Towers STACK) 16 Operating Scenario: OS -4 Emission Source/Group ID: G-9 10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2021) Hours per Day ( 23 ) Days per Week ( 6 ) Weeks per Year ( 52 ) 11. Typical Start & End Times For Operating Scenario: Start: 0 End: 2359 12. Seasonal Periods Percent Annual Throughput: Jan-Feb + Dec y March-Ma June-Aug. Sept.-Nov. o 2021 25% 2021 25% 2021 25% 2021 25/a 13. Actual Emissions per Pollutant Listed : Attach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG GHG Estimation Emission Ef Pollutants CAS Efficiency Pollutants Method Code Factor Control (Tons/Year) (See Instructions) all controls) 2021 Criteria Emissions- Emission Control Emission EF Pollutant Criteria (NAAQS) Estimation Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2021 TSP TSP 0.2 08 0.00051 Emission HAP/TAP CAS Emissions Estimation Control Emission EF Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2021 17 Facility Total CY 2021 Emissions Summary Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2021 Record Facility-Wide Totals From all Permitted and Non-Permitted Air Pollutant Emission Sources Green house Gases Pollutants(GHG) Actual Emissions(Tons/Year) Pollutant CAS 2021 12020 %Change Carbon Dioxide(CO2) 124389 182679.6427 117784.6233 927.1775% Criteria Pollutants Actual Emissions(Tons/Year) Pollutant CAS 2021 2020 %Change CO CO .74 .7 5.7142887% NOx NOx 24.57 22.03 11.529728% PM(TSP) TSP 1.23 1.01 21.782183% PM 10 PM 10 1.03 .82 25.609755% PM2.5 PM2.5 1.03 .56 83.928566% S02 IS02 1.33 .23 143.478264% VOC I VOC 1.85 .87 -2.2988484% Hazardous Air Pollutants(HAPS) and/or Toxic Air Pollutants(TAPs) Actual Emissions(Pounds/Year) Pollutant I CAS 12021 12020 1%Change Pollutant Group:Arsenic&Compounds(total mass of elemental AS,arsine and all inorganic compounds)Group Sum:.08561 Arsenic Unlisted Compounds- Specify Compound(Component of ASC-Other .08561 TO 7979 T941456% ASC) Pollutant Group:Beryllium&compounds(Total mass) Group Sum:.03556 Beryllium Unlisted Compounds- Specify Compound(Component of BEC-Other .03556 .03109 14.377613% BEC) Pollutant Group:Cadmium&compounds(total mass includes elemental metal)Group Sum:.15214 Cadmium Unlisted Compounds- Specify Compound(Component of CDC-Other 15214 .22379 -32.01662% CDC) Pollutant Group:Chromium(VI)Non-Specific Compounds,as Chrom(VI)(Component CRC)Group Sum:.03447 18 Chromium(VI)Non-Specific Unlisted Compounds- Specify NSCR6-Other 03447 .03208 7.450128% Compound(Component of NSCR6&CRC) Pollutant Group:Chromium-All/Total(includes Chromium(VI)categories,metal and others)Group Sum:.03447 Chromium(VI)Non-Specific Unlisted Compounds- Specify NSCR6-Other .03447 .03208 7.450128`1/0' Compound(Component of NSCR6&CRC) Pollutant Group:Lead&compounds Group Sum:2.49983 Lead Unlisted Compounds- Specify Compound(Component of PBC-Other 2.49983 3.51174 -28.81506% PBC) Pollutant Group:Manganese&compounds Group Sum:.76014 Manganese Unlisted Compounds- Specify Compound(Component of MNC-Other .76014 .65057 16.84216% MNC) Pollutant Group:Mercury&Compounds-all total mass includes Hg Vapor Group Sum:.20388 Mercury Unlisted Compounds- Specify Compound(Component of I HGC-Other 20388 .17029 19.725178% HGC) Pollutant Group:Nickel&Compounds,sum total mass includes elemental Group Sum:1.52392 Nickel Unlisted Compounds NIC-Other 552392 1.31116 16.22686% (Component of NIC-Specify) Pollutant Group:Polycyclic Organic Matter(Specific Compounds from OAQPS for TV)Group Sum:O Tetrachlorodibenzo-p-dioxin, 2,3,7,8-(Component of CLDC& 1746-01-6 0 0 NaN% 83329/POMTV) Ammonia(as NH3) 7664-41-7 41.984 51.2192 -18.030737% Chlorine 7782-50-5 7.52723 6.91295 8.885928% Fluorides(sum of all fluoride 16984-48-8 8.13818 7.30578 11.393716% compounds as mass of F ion) Formaldehyde 50-00-0 .984 1.20046 -18.031416% Hexane,n- 110-54-3 23.616 128.8108 -18.03074% Hydrogen chloride(hydrochloric 7647-01-0 256.39593 E7.3O578 1269.3511% acid) Hydrogen fluoride(hydrofluoric acid as mass of HF)(Component 7664-39-3 8.13818 11.393716% of 16984488/Fluorides) 19 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem DAQ Internal Comments: 2021 stack test for PM, HCL, Pb, Cd, and HG used to update factors, resulted in emissions increases/decreases. Change to slightly more conservative emissions estimation methodology resulted in emissions increases for other pollutants. Natural gas usage decreased which resulted in decrease in hexane, ammonia, and formaldehyde emissions 20 Approved COR Date Submitted: 10/26/2022 15:26:36 Facility Name: Stericycle, Inc. Facility ID : 0100010 1168 Porter Avenue Permit : 05896 Haw River,NC 27258 County : Alamance DAQ Region : Winston-Salem Comments From Reviewer: 21 22