Loading...
HomeMy WebLinkAboutAQ_F_0200088_20221207_CMPL_InspRpt NORTH CAROLINA DIVISION OF Mooresville Regional Office AIR QUALITY Triumph Insulation Systems,LLC NC Facility ID 0200088 Inspection Report County/FIPS:Alexander/003 Date: 12/06/2022 Facility Data Permit Data Triumph Insulation Systems,LLC Permit 08934/R06 138 Wittenburg Industrial Drive Issued 4/2/2018 Taylorsville,NC 28681 Expires 3/31/2026 Lat: 35d 50.2770m Long: 81d 10.7682m Class/Status Synthetic Minor SIC: 3497/Metal Foil And Leaf Permit Status Active NAICS: 322225/Laminated Aluminum Foil Manufacturing for Flexible Current Permit Application(s)None Packaging Uses Program Applicability Contact Data SIP Facility Contact Authorized Contact Technical Contact Amanda Pearson Amanda Pearson Ken Harmon General Manager General Manager Maintenance Technician (828)261-6395 (828)261-6395 (828)632-6666 Compliance Data Comments: Inspection Date 12/06/2022 Inspector's Name Sandra Sherer Inspector's Signature: Satidla SheM 09M Operating Status Operating Compliance Status Compliance-inspection Action Code FCE Date of Signature: 12/7/2022 Inspection Result Compliance Total Actual emissions in TONS/YEAR: TSP S02 NOX VOC CO PM10 x HAP 2018 0.0200 --- 0.4300 1.14 0.0700 0.0200 1706.96 2017 0.0300 --- 0.5100 1.31 0.0800 0.0300 2053.70 *Highest HAP Emitted in ounds Five Year Violation History:None Date Letter Type Rule Violated Violation Resolution Date Performed Stack Tests since last FCE: None Date Test Results Test Method(s) Source(s)Tested Triumph Insulation Systems, LLC December 6, 2022 Page 2 Type Action: X Full Compliance _Partial Compliance _Complaint Other: Evaluation Evaluation/Reinspection Investigation Data Date submitted for initial review 12/6/2022 _IBEAM INFO, WARNING/OB,NOD,NOV,NRE Tracking: X IBEAM Document X IBEAM Inspection, list date inspected X IBEAM LAT/LONG,Facility Locked X IBEAM Inspection, list date draft is submitted X IBEAM LAT/LONG,Coordinates checked X IBEAM Inspection,pollutants/programs checked _IBEAM Complaint X IBEAM Planning,Next Inspection Date 12/1/2023 Directions: Take 1-77 north, 1-40 west, and go north on NC 16 (from exit #132). Take a right onto Wittenburg Road (at traffic signal, across from Friendship Church Road). Turn right onto Wittenburg Industrial Drive. The facility is located at the end of the street on the right. Safety Equipment: Safety shoes and safety glasses are required. Safety Issues: None noted. Lat/Long: A review of the facility's coordinates on "Maps of DAQ Regulated Facilities" indicates the facility's latitude and longitude coordinates are accurate. Email Contacts: Updated facility and authorized contacts email in IBEAM. 1. General Information. The purpose of this site visit was to conduct an Air Quality compliance inspection. Ms. Amanda Pearson, General Manager, accompanied me on the inspection. This facility manufactures fire retardant laminate used primarily in transportation systems(aircraft, boats). This laminate is a layer between the outer surface and insulation designed to prevent fire from spreading and is designed to withstand a 2000-degree F flame for a certain time period. The facility is now operating eight hours per day, 5 days per week, 51 weeks per year. 2. File Review. A. Contacts. Updated facility and authorized contacts to Amanda Pearson, General Manager. B. Files. The following files were reviewed prior to the inspection: previous inspection reports; correspondence since the last inspection; etc. C. Compliance history: The facility has not had any compliance issues in the last five years. D. Operating Conditions established by Stack Testing. A stack test was conducted on October 24,2017 to document RTO efficiency. Triumph Insulation Systems, LLC December 6, 2022 Page 3 E. NSPS/NESHAP Review The facility is not subject to any NSPS or NESHAP regulation at this time. 3. Observations of permitted air emission sources and control devices: Emission Emission Source Control Control System Source ID Description System ID Description ESOI, ES02 propane-fired laminator CD01 propane-fired (ID No. ESO 1; 4.8 ;regenerative thermal million Btu per hour oxidizer(3.0 million Btu maximum heat input rate). ;per hour heat input rate) ,and mixing room (ID No. JES02) Observed. This equipment was in operation during the inspection with no visible or odorous emissions. 4. Observations of insignificant air emission sources and control devices listed on the current per—M—it: Source Exemption 'Source of Source of Title V Reg Pollutants? IIES-I -propane r--ed—s-p—a ce—he-at-c`r(_6 5,666 2Q .6102 No Yes (g)(5)(A ,Btu per hour heat input) IES-2 -propane-fired space heater(65, .0102 No Yes ;Btu per hour heat input) .IES-3 -propane-fired space heater(, , Co, (g)(5)(A 2(6 .0102 No Yes 'Btu per hour heat input) (g)(5)(A) JES-4 -propane-fired space heater(45,000 [2Q .0102 No Yes ,Btu per hour heat input) (g)(5)(A) JES-5 -propane-fired space heater(45-6-6-6-24_._6_16_2 No Yes ,Btu per hour heat input) Observed. The comfort heat space heaters were observed during the inspection. They were operating with no issues noted. 5. Observations of air emission sources and control devices not listed on the current permit: The facility has two insignificant sources based on the scale of activity. • The facility has a 150 foot per minute printer which is ducted to the oxidizer. • The facility has a small MEK distiller which is ducted to the oxidizer. These items were previously added to the yellowsheet. The printer was operating during the inspection with no visible or odorous emissions. Triumph Insulation Systems, LLC December 6, 2022 Page 4 6. Compliance with specific permit conditions and limitations: a. Condition A.2. A NCAC 2Q .0304(d) and(f)"Permit Renewal and Emission Inventory"The Permittee, at least 90 days prior to the expiration date of this permit. The report shall be submitted to the Regional Supervisor, DAQ and shall document air pollutants emitted for the 2024 calendar year. Observed. The permit expires on March 31,2026. No further action is required at this time. b. Condition A.3 15A NCAC 2D .0516 "Sulfur Dioxide Emissions from Combustion Sources," sulfur dioxide emissions from propane-fired laminator(ID No.ESO1)shall not exceed 2.3 pounds per million Btu heat input. Observed. The facility is tracking the amount of propane combusted. The amount of sulfur in the propane is below the permit limit. Compliance is indicated. c. Condition AA 15A NCAC 2D .0521 "Control of Visible Emissions," visible emissions from the emission sources, manufactured after July 1, 1971, shall not be more than 20 percent opacity. However, sources which must comply with a visible emissions standard in 15A NCAC 2D .0524 "New Source Performance Standards" or .1110 "National Emission Standards for Hazardous Air Pollutants" shall meet that standard instead of the 2D .0521 visible emissions standard. Observed. The facility was operating during the inspection. No visible emissions were observed at the facility. Compliance is indicated. d. Condition A.S. 15A NCAC 2D .0535,the Permittee of a source of excess emissions that last for more than four hours and that results from a malfunction, a breakdown of process or control equipment or any other abnormal conditions, shall notify MRO of any such occurrence by 9:00 am the next business day. Observed. No excess emissions were experienced during the past year. Compliance is indicated. e. Condition A.6, 15A NCAC 2D .0540 "Particulates from Fugitive Dust Emission Sources,"the Permittee shall not cause or allow fugitive dust emissions to cause or contribute to substantive complaints or excess visible emissions beyond the property boundary. Observed. No complaints of fugitive dust or visible emissions have been reported since the last inspection. Compliance is indicated. £ Condition A.7. 15A NCAC 2D .0605 "Compliance Certification",the Permittee shall submit a compliance certification to the DAQ and the EPA. The certification shall encompass the current calendar year from January I`to the effective date of permit 08934R06(April 2,2018). The certification will verify that the facility was meeting all of the conditions of the Title V permit at the time of the permit change. Observed. The facility submitted a compliance certification on April 20,2018 for the January to March 30, 2018 time period. Compliance is indicated. g. Condition A.B. 15A NCAC 2D .1806 "Control and Prohibition of Odorous Emissions"the Permittee shall not operate the facility without implementing management practices or installing Triumph Insulation Systems, LLC December 6, 2022 Page 5 and operating odor control equipment sufficient to prevent odorous emissions from the facility from causing or contributing to objectionable odors beyond the facility's boundary. Observed.No objectionable odors were detected beyond the facility boundary. Compliance is indicated. h. Condition A.9. 15A NCAC 2Q .0315 "Synthetic Minor Facilities,"to avoid the applicability of 15A NCAC 2Q .0501 "Purpose of Section and Requirement for a Permit,"facility-wide emissions shall be less than the following: Pollutant _ Emission Limit (Tons per consecutive 12-month period) Yndividual RAPS_ 10 j Total HAPs T 25 a. Inspection and Maintenance Requirements— i. Thermal Oxidizer Requirements -Emissions shall be controlled as described in the permitted equipment list. To comply with the provisions of this permit and ensure that emissions do not exceed the regulatory limits,the Permittee shall perform periodic inspections and maintenance(I&M)as recommended by the manufacturer.As a minimum,the Permittee shall perform an annual(for each 12 month period following the initial inspection)internal inspection of each primary heat exchanger and associated inlet/outlet valves to ensure structural integrity. b. Monitoring Requirements— i. Thermal Oxidizer Requirements -The Permittee shall ensure the proper performance of each thermal oxidizer by monitoring the following operational parameters: A. The Permittee shall continuously record the temperature measured inside the second half of the oxidizer(away from the flame zone)with a minimum temperature of 1600 degrees Fahrenheit. B. The Pennittee shall record the flow rate to the oxidizer(maximum flow rate of 15,000 scfm) once per week. c. Recordkeeping Requirements i. A logbook shall be kept on site for thermal oxidizer(ID No. CDOI). Observed. The facility is maintaining records of the total HAP and individual HAP emissions for calendar year January 2022 through November 2022. Total HAPs and individual RAPS for the calendar year 2022 are well below the emission limits. The oxidizer was operating with a chamber temperature of 1818 °F and a flow rate to the oxidizer of 8060 scfm during the inspection. The facility has been conducting periodic inspections and maintenance on the oxidizer. Ms. Pearson provided the required temperature and flow rate recordings on his computer and has the flow rate and temperature readings listed every week from the previous inspection to November 30, 2022. The last two internal inspections of the oxidizer were Triumph Insulation Systems, LLC December 6, 2022 Page 6 conducted June 7, 2021 and June 7, 2022. The facility has an outside contractor perform the inspection. Compliance is indicated. f. TOXIC AIR POLLUTANT EMISSIONS LIMITATION REQUIREMENT-Pursuant to 15A NCAC 2Q .0711 "Emission Rates Requiring a Permit," for each of the below listed toxic air pollutants(TAPs),the Permittee has made a demonstration that facility-wide actual emissions, where one or more emission release points are obstructed or non-vertically oriented,do not exceed the Toxic Permit Emission Rates(TPERs) listed in 15A NCAC 2Q .0711(a).The facility shall be operated and maintained in such a manner that emissions of any listed TAPS from the facility, including fugitive emissions,will not exceed TPERs listed in 15A NCAC 2Q .0711(a). a. A permit to emit any of the below listed TAPS shall be required for this facility if actual emissions from all sources will become greater than the corresponding TPERs. b. PRIOR to exceeding any of these listed TPERs,the Permittee shall be responsible for obtaining a permit to emit TAPs and for demonstrating compliance with the requirements of 15A NCAC 2D .1100 "Control of Toxic Air Pollutants". c. In accordance with the approved application,the Permittee shall maintain records of operational information demonstrating that the TAP emissions do not exceed the TPERs as listed below: Chronic 1 Acute ' Pollutant Carcinogens Toxicants Acute Systemic Irritants (lb/yr) (lb/day) Toxicants (ib/hr) , (Ib/hr) JAmmonia(as NH3))((7664-41 7) v�l _ 0.68 Ethyl acetate(141-78-6) 36 MEK(methyl ethyl ketone, 2- 78 22.4 1'butanone)(78-93-3 'Toluene 108-88-3 98 14.4 Observed. The facility provided records that document the daily/hourly emissions of the above TAPS. The facility only uses MEK and Toluene.The level of emissions had not exceeded the TPER limits during the period reviewed from January 2022 to November 2022. Compliance is indicated. 7. Summary of changes needed to the current permit: None. 8. Compliance assistance offered duringthe�e inspection: None 9. Section 112(r) applicability: This facility does not appear to be subject to the requirements of the Chemical Accident Release Prevention Program, Section I I2(r)of the Clean Air Act. Triumph Insulation Systems,LLC December 6, 2022 Page 7 10. Compliance determination: Based on my observations,this facility appeared to be in compliance with the applicable air quality regulations at the time of the inspection. SLS: C: MRO File https:Hncconnect.sharepoiiit.com/sites/DAQ-MRO/Counties/ALEXANDER/00088/lNSPECT 20221206.doex