Loading...
HomeMy WebLinkAboutAQ_F_0700070_20211228_PRMT_PmtApp AgriBusiness Environmental Services & Sustainability www.perdueagribusiness.com® December 16, 2021 Hand Delivered Ms. Betsy Huddleston, Regional Air Quality Supervisor NCDENR DAQ Washington Regional Office 943 Washington Square Mall Washington,North Carolina 27889 Subject: Renewal of Air Quality Permit No. 03107R17 Perdue AgriBusiness LLC- Pantego Pantego Facility, ID : 0700070 Beaufort County Dear Ms. Huddleston: Per the forthcoming expiration of our existing air permit, I am forwarding this letter as a formal request for its renewal. There have been no process or control equipment changes, nor are any changes planned that would affect emissions at the subject facility. I have included the original and one copy of the following forms: Form AA, Aero Confirmation, Certification Form, and spreadsheets for inventory calculations (CY 2020). I hope this meets with your approval and if you should have any questions regarding this renewal request please contact me at 252-348-4383. Sincerely, --� n ��� _ oey B�ggett egional Environmental Manager Perdue AgriBusiness LLC /enclosures: Air Emission Spreadsheets, Aero Confirmation, Certificati7_ (Form AA L221 -T W�� O We Believe In Responsible Food and Agriculture FORM A GENERAL FACILITY INFORMATION REVISED 09/22/16 NCDEO/Divislon of Air Quality-Application for Air Permit to ConstructIOperate A NOTE-APPLICATION WILL NOT BE PROCESSED WITHOUT THE FOLLOWING: ❑ Local Zoning Consistency Determination ❑ Appropriate Number of Copies of Application Application Fee(please check one option below) (new or modification only) El Responsible Official/Authorized Contact Signature ❑ P.E.Seal(if required) ❑ Not Required ❑ePaymenl ❑ Check Enclosed GENERAL INFORMATION Legal Corporate/Owner Name: Perdue AgnSusiness LLC Site Name: Pantego Crain Site Address(911 Address)Line i i 1461 Swindell Road Site Address Line 2. City: Pautego Slate: North Carolina Zip Code: 27860 County: Beaufort CONTACT INFORMATION Responsible Official/Authorized Contact: Invoice Contact: Namelfitle: Sharon Clark,SVP Regulatory Affairs 6 Compliance Namerrille: Joey Baggett, Regional Environmental Manager Mailing Address Line 1: 6906-Zion Church Road Mailing Address Line 1: 242 Perdue Road Mailing Address Line 2: PO Box 1537 Mailing Address Line 2: City: Salisbury Slate: Maryland Zip Code: 21802-1537 City: Colield Slate: Min Caroh Zip Code: 27922 Primary Phone No.: 410-314-2609 Fax No.: Primary Phone No.: 252-348-4383 Fax No.: Secondary Phone No.. Secondary Phone No.: 252-287-5196 Email Address- sharon.clarkAperdue.com Email Address: loey.baggett(alperdue.com Facility/Inspection Contact: PermitlTechnical Contact: Name/Title: Austin Hodges.Grain Manager Name/Tille. Joey Baggett, Regional Environmental Manager Mailing Address Line 1 1461 Swindell Road Mailing Address Line 1: 242 Perdue Road Mailing Address Line 2: Mailing Address Line 2: Cily: Panlego Slate: North Carolina Zip Code: 27860 City: Cofield Slate: xth Caroh Zip Code: 27922 Primary Phone No.: 252-945-8472 Fax No.: Primary Phone No.: 252-348-4383 Fax No.: Secondary Phone No.. Secondary Phone No.: 252-287-5196 Email Address. austin.hodges(a> perdue_com Finail Address: joev.baeaettoperdue.ccm APPLICATION IS BEING MADE FOR U New Non-permitted Facility/Greenfield ❑ Modification of Facility(permitted) ❑ Renewal Title V Renewal Non-Title V ❑ Name Change ❑ Ownership Change ❑ Administrative Amendment ❑ Renewal with Modification FACILITY CLASSIFICATION AFTER APPLICATION(Check Only One) ❑ General ❑' Small ❑ Prohibitory Small ❑ Synthetic Minor ❑ Title V FACILITY(Plant Site)INFORMATION Grain receiving,storage,drying,shipment. Facility ID No. 0700070 Primary SIC/NAICS Code: 5153 CurrentlPrevious Air Permit No.03107R18 Expiration Dale:513112022 Facility Coordinates Latitude: 35'36.553'N Longitude:76'40.628'W Does this application contain —If yes,please contact the DAQ Regional Office prior to submitting this confidential data? ❑ YES El NO application.— (See Instructions) PERSON OR FIRM THAT PREPARED APPLICATION Person Name: Joey Baggett Firm Name: Mailing Address Line 1: 242 Perdue Road Mailing Address Line 2: City:Cofield State: North Carolina Zip Code: County: Phone No.. 252-348-4383 Fax No.. Email Address. SIGNATURE OF RESPONSIBLE OFFICIAUAUTHORIZED CONTACT Name(typed): Sharon Clark Title:SVP Regulatory Affairs 8 Compliance X Signature(Blue Ink): :.lr 'W C l l (/)ow K_ Date: ' 1 I g q/ j i Attach Additional Sheets As Necessary Page 1 o DEC 2 8 2021 Dir AQ V 11 AR0 FORM A (continued, page 2 of 2) GENERAL FACILITY INFORMATION REVISED 09/22/16 NCDEQ/Division of Air Quality-Application for Air Permit to Construct/Operate A SECTION AA1 -APPLICATION FOR NON-TITLE V PERMIT RENEWAL Perdue A riBusiness LLC (Company Name)hereby formally requests renewal of Air Permit No. 03107R18 There have been no modifications to the originally permitted facility or the operations therein that would require an air permit since the last permit was issued. Is your facility subject to 40 CFR Part 68"Prevnetion of Accidental Releases"-Section 112(r)of the Clean Air Act? ❑ YES O NO If yes,have you already submitted a Risk Manage Plan(RMP)to EPA? ❑ YES ❑ NO Date Submitted: Did you attach a current emissions inventory? EI/ YES ❑ NO If no,did you submit the inventory via AERO or by mail? Cd Via AERO ❑ Mailed Date Mailed: SECTION AA2-APPLICATION FOR TITLE V PERMIT RENEWAL In accordance with the provisions of Title 15A 2Q.0513,the responsible official of (Company Name) hereby formally requests renewal of Air Permit No. (Air Permit No.)and further certifies that: (1) The current air quality permit identifies and describes all emissions units at the above subject facility,except where such units are exempted under the North Carolina Title V regulations at 15A NCAC 2Q.0500; (2) The current air quality permit cits all applicable requirements and provides the method or methods for determing compliance with the applicable requirements; (3) The facility is currently in compliance,and shall continue to comply,with all applicable requiremetns. (Note: As provided under 15A NCAC 2Q.0512 compliance with the conditions of the permit shall be deemed compliance with the applicable requirements specifically identified in the permit); (4) For applicable requirements that become effective during the term of the renewed permit that the facility shall comply on a timely basis, (5) The facility shall fulfill applicable enhanced monitoring requirements and submit a compliance certification as required by 40 CFR Part 64. The responsible official(signature on page 1)certifies under the penalty of law that all information and statements provided above,based on information and belief formed after reasonable inquiry,are true,accurate,and complete. SECTION AA3-APPLICATION FOR NAME CHANGE New Facility Name: Former Facility Name: An official facility name change is requested as described above for the air permit mentioned on page 1 of this form. Complete the other sections if there have been modifications to the originally premitted facility that would requie an air quality permit since the last permit was issued and if ther has been an ownership change associated with this name change. SECTION AA4-APPLICATION FOR AN OWNERSHIP CHANGE By this application we hereby request transfer of Air Quality Permit No. from the former owner to the new owner as described below. The transfer of permit responsibility,coverage and liability shall be effective (immediately or insert date.) The legal ownership of the facility described on page 1 of this form has been or will be transferred on (date). There have been no modifications to the originally permitted facility that would require an air quality permit since the last permit was issued. Signature of New(Buyer)Responsible Official/Authorized Contact(as typed on page 1) X Signature(Blue Ink): Date: New Facility Name: Former Facility Name: Signature of Former(Seller)Responsible Official/Authorized Contact: Name(typed or print): Title: X Signature(Blue Ink): Date: Former Legal Corporate/Owner Name: In lieu of the seller's signature on this form,a letter may be submitted with the seller's signature indicating the ownership change SECTION AA5-APPLICATION FOR ADMINISTRATIVE AMENDMENT Describe the requested administrative amendment here(attach additional documents as necessary): Attach Additional Sheets As Necessary Page 2 of 2 LIQUEFIED PETROLUEM GAS(LPG)C MBUSTION EMISSIONS CALCULATOR-REVISION F 01/05/2017-OUTPUT SCREEN Instructions: Enter emission source/facility data on the"INPUT'tablscreen. The air emission results and summary of input data are viewed/printed on the"OUTPUT'tablscreen. The different tabs are on the bottom of this screen. ®r- This spreadsheet is for your use only and should be used with caution.NCDEQ does not guarantee the accuracy of the information contained. This spreadsheet is subject to continual revision and updatlnq. It is your responsibility to be aware of the most current Air Quapty Information available. NCDEQ is not responsible for errors or omiss -hat may be contained herein. SOURCE 1 FACILITY1 USER INPUT SUMMARY(FROM INPUT EN COMPANY: Perdue AgriBuslness LLC,Pantego FACILITY PERMIT NUU MBEBE R: 03107R17 EMISSION SOURCE DESCRIPTION 46 MMBTU/HR FIRED BOILER FACILITY CITY: Pant ego EMISSION SOURCE ID NO.: ES-5 FACILITY COUNTY: Beaufort SPREADSHEET PREPARED BY: Joey Baggett LPG Man ACTUAL FUEL THROUGHPUT: 82,786 GAL/YR FUEL HEAT VALUE: BTU/Gal Propane: POTENTIAL FUEL THROUGHPUT: 4,428 132 GAL/YR HHV USED FOR GHGe 0.091 mm BTU/Gal Butane: REQUESTED MAX.FUEL THRPT: 4,42 ,132 GAUYR BOILER TYPE: INDUSTRIAL METHOD USED TO COMPUTE ACTUAL GHG EMISSIONS: TIER 1: DEFAULT HIGH HEAT VALUE AND DEFAULT Er- CARBON CONTENT USED FOR GHGS k C/ al: CARBON CONTENT NOT USED FOR CALCULATION TIER CHOSEN CAFTWMAIR POLLUTANT EMISSIONS INFORMATION ACTUAL EMISSIONS POTENTIAL EMISSIONS EMISSION FACTOR (AFTERCCNTROLS/LARTS) (BEFORE-TROLS LIMITS) (AFTER CONTROLS/LIMITS) IWmm9tu AIR POLLUTANT EMITTED Ib/hr ton Ib/hr tons/yr Ib/hr tonstyr uncontrolled oorltrollod PARTICULATE MATTER(Total) 0.02 0.00 0.02 0.11 0.02 0.11 0.00053 0.00053 PARTICULATE MATTER Filterable 0.01 0.00 0.01 0.04 0.01 0.04 0.00021 0.00021 PARTICULATE MATTER Condensable 0.02 0.00 0.02 0.07 0.02 0.07 0.00033 0.00033 PM 2.5 Total 0.02 0.00 0.02 0.09 0.02 0.09 0.00045 0.00045 PM 2.5 Filterable 0.01 0.00 0.01 0.02 0.01 0.02 0.00011 0.00011 SULFUR DIOXIDE S02 0.01 0.00 0.01 0.03 1 0.01 0.03 1.63E-04 1.63E-04 NITROGEN OXIDES NOx 6.54 0.54 6.54 28.66 6.54 28.66 0.142 0.142 CARBON MONOXIDE CO 3.77 0.31 3.77 16.52 3.77 16.52 0.082 0.082 VOLATILE ORGANIC COMPOUNDS VOC 0.50 0.04 0.50 2.20 0.50 2.20 0.011 0.011 TOXIC/HAZARDOUS AIR POLLUTANT EMISSIONS INFORMATION ACTUAL EMISSIONS POTENTIAL EMSSIONS EMISSION FACTOR CAS (AFTER CONTROLS I LIMITS) (BEFORE CONTROLS/LIMITS) (AFTER CONTROLS fl1Y1T8) IWmnnBtu TOXIC I HAZARDOUS AIR POLLUTANT NUMBER IWRr t IWhr tonsw IbIIN 7 tonstyr uncontrolled wntrolled TOXIC AIR POLLUTANT EMISSIONS INFORMATION FOR PERMITTING PURPOSES EXPECTED ACTUAL EMISSIONS AFTER CONTROLS/LIMITATIONS EMISSION FACTOR IWmmBtu TOXIC AIR POLLUTANT CAS Num. IWhr INday Ie/yr uncontrolled lcontmiied GREENHOUSE GAS POLLUTANT EMISSIONS INFORMATION(FOR EMISSION INVENTORY GHG-POTENTIAL TO EMIT PURPOSES) NOT BASED ON EPA MRR METHOD ACTUAL EMISSIONS POTENTIAL EMISSIONS With Requested POTENTIAL EMISSIONS-utilize max heat input PROPANE EPA MRR CALCULATION METHOD: TIER f capacity and EPA MRR Emission Factors Emission Limitation-utilize requested fuel limit and EPA MRR Emission Factors GREENHOUSE GAS EMITTED metric tonstyr metric tonstyr,CO2e short tons/yr short tons/yr short tons/yr,CO2e short tons/yr short tons/yr,CO2s CARBON DIOXIDE(CO2) 463.01 463,01 510.38 27,299.72 27,299.72 27,299.72 27,299.72 METHANE(CHa) 2.26E-02 5.65E-01 2.49E-02 1.33E+00 3.33E+01 1.33E+00 3.33E+01 NITROUS OXIDE(NZO) 4.52E-03 1.35E+00 4.98E-03 2.67E-01 7.94E+01 2.67E-01 7.94E+01 TOTAL 464.92 TOTAL 27,412.46 TOTAL 27,412.46 NOTE: CO2e,means CO2 equivalent. NOTE: The DAQ Air Emissions Reporting Online(AERO)system requires short tons be reported. The EPA MRR requires metric tons be reported. Facility: I'antego 2020 Facility ID# : 0700070 ACTUAL CALCULATIONS Permit# 03107R17 Emission Factors From AP-42 Grain Elevators and Processes 2003) PROCESS DESCRIPTION In Tons CONTROL TSP Emission TSP Act. PM 10 Emission PM 10 Act. M 2.5 Emissio PM 2.5 Act. YEAR I EFFECIENCY lFactor(lb/ton) Emissionslb/ Factor(lb/ton) lEmissionslb/ Factor lb/tonlEmissionsib/yr Elevator Operations RECEIVING TRUCK RECEIVING 47,833.00 1.000 0.035 1674.16 0.0078 373.10 0.0013 62.18 RAIL RECEIVING 1.000 0.032 0.00 0.0078 0.00 0.0013 0.00 GENERAL RECEIVING 5,735.00 1.000 0.18 1032.30 0.059 338.37 0.01 57.35 INTERNAL OPERATIONS BELTS,HEADHOUSE,CLEANING 53,568.00 1.000 0.061 3267.65 0.034 1821.31 0.0058 310.69 CLOSED-LOOP SYSTEM(TURNHEAD) 1.000 0 0.00 0 0.00 0.00 CLEANING 1 0.075 0 0.0188 0 0.0032 0.00 DRYING Column 42,554.00 1 0.22 9362 0.055 2340 0.0094 400.01 Rack 1 3 0 0.75 0 0.13 0.00 BIN LOADING(VENTS) GENERAL 53,568.00 1.000 0.025 1339.20 0.0063 337.48 0.0011 58.92 LOADOUT(SHIPPING) TRUCK 13,655.00 1.000 0.086 1174.33 0.029 396.00 0.0049 66.91 RAIL L 31,372.00 1 1.000 0.027 847.04 0.0022 69.02 0.00037 11.61 TSP 18696.56 PM 10 5675.74 PM 10 1 967.68 Total in Ibs/Yr Total in Ibs/Yr Total in Ibs/Yr In Tons Year In Tons Year In Tons Year 9.35 2.84 0.48 Facility Tons a Year Total 12.67 This form is for Non-Title V facilities.If this facility is classified as Title V,please obtain and use the appropriate form COPY of RECORD Date Submitted: 12/17/2021 11:01 :23 Inventory Certification Form(Non-Title V) Facility Name: Perdue Grain and Oilseed,LLC-Pantego Facility ID : 0700070 1461 Swindell Road Permit: 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory-Calendar Year 2020 These forms must be completed and returned even if the facility did not operate or emissions were zero The legally defined "Responsible Official"of record for your facility is Susan Murphy This person or one that meets the definition below must sign this certification form. The official submitting the infonnation must certify that he/she complies with the requirements as specified in Title15A NCAC 2Q.03040)which define the responsible official as the following: 1. For corporations,by principal executive officer of at least the level of vice-president,or his duly authorized representative, if such representative is responsible for overall operationof the facility from which the emissions described in the permit application form originates 2. for partnership or limited partnership,by a general partner 3. for a sole proprietorship,by the proprietor 4. for municipal, state federal, or other public entity,by a principal executive officer, rankingelected official,or other duly authorized employee CERTIFICATION STATEMENT: (important: Legally Responsible Official read and sign after all submissions are final.) 1 certify that I am the responsible official for this facility,as described above,and hereby certify that the information contained in this air emissions report, including attached calculations and documentation, is true, accurate and complete. (Subject to legal penalties of up to$25,000 per occurrence and possible imprisonment as outlined in G.S. § 143-215.3(a)(2)) Responsible Official's Signature Below (use blue ink): Date Signed: Printed Name: Susan Murphy_ Signature: This form applies to Non Title V facilities.If this facility is classified asTitle V,please telephone your regional office Emission Inventory Contact at once for proper formsand classification. Email address of Responsible Official: S*dsett. am; S�1a UT1.(1ary,� Information on this Form cannot be held confidential COPY of RECORD Date Submitted: 12/17/2021 11:01:23 ECEIVE 0 EC 2 8 2021 DAQ WARO 1 COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO Listing of Emission Sources and Control Devices on Permit.See instructions *ES ID on *ES Description GCS ID ;CS Description CD ID's Air Permit 3,000 bushels per hour Zimmerman ;S-1 grain dryer(propane-fired,28.8 million Btu per hour maximum heat input) Dump pit with a three-sided ;S-2 enclosure on one 15,000 bushels per hour receiving elevator leg ;S-3 7,000 bushels per hour shipping elevator leg with two loadout chutes ;S-4 Rail/truck loadout spout 4,700 bushels per hour Zimmerman ;S-5 grain dryer(propane-fired,46 million per Btu hour maximum heat input) i P P ) -ES-BV Bin Vents COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO mission Source & Operating Scenario List- See Instructions *ES Group ID 'ES ID *OS ID *OS Description ES-1 1 Wet leg to grain dryer and from dryer to storage ES-2 2 Grain receiving 5 Grain drying ES-3 3 Grain loadout for trucks ES-4 4 Grain loadout for railcars ES-5 7 Wet leg to grain dryer and from grain dryer to storage. I-ES-BV 6 Bin Loading Vents COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC -Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 Emission Source ID(from permit) ES-1 or Emission Source Group ID Emission Source Description : 3,000 bushels per hour Zimmerman grain dryer(propane-fired, 28.8 million Btu per hour maximum heat input) Operating Scenario ID/ OS - 1/Wet leg to grain dryer and from dryer to storage Description: SCC Number/Description: 10301003/Propane/Butane ; Butane/Propane Mix Throughput/units in 2020: (e.g.production or fuel use): Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu units) Capture Efficiency (%of Emissions from this Process Vented to Control Device or Stack): Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines): :RP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm) Rectangle(L x W) (in 0.1 feet) FUGITIVE (NO Grain Dryer F1 STACK) 0.1 70 Area= 0 Fugitive 1perating Scenario: OS - 1 Emission Source/Group ID: ES-1 ). Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 ) 1.Typical Start& End Times For Operating Scenario: Start: 0 End: 2359 !. Seasonal Periods Percent Annual Throughput: an-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25% 020 1 2020 1 2020 1 2020 L Actual Emissions per Pollutant Listed : ttach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG CAS GHG Estimation Efficiency Emission Ef Pollutants Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Pollutant Criteria Estimation Emission Ef (NAAQS) Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 CO CO 08 NOx NOx 08 TSP TSP 08 PM10 PM10 08 PM2.5 PM2.5 08 S02 S02 08 VOC VOC 08 Emission HAP/TAP Emissions Control Emission EF CAS Estimation Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control (pounds/Year) Method Code (Net after all controls) (See Instructions) 2020 COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed,LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego, NC 28760 County : Beaufort DAQ Region : WARO North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 Emission Source ID (from permit) ES-2 or Emission Source Group ID Emission Source Description : Dump pit with a three-sided enclosure on one 15,000 bushels per hour receiving elevator leg Operating Scenario ID/ OS - 2/Grain receiving Description: SCC Number/Description: 3020060 1/Feed and Grain Country Elevators ; Shipping/Receiving ** Throughput/units in 2020: 53568 TON/yr (e.g.production or fuel use): Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) Capture Efficiency (%of Emissions from this Process Vented to Control Device or Stack): Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) Emission Release Point(ERP) Information: (sources vented to more than one ERP use additional entry lines): :RP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet sec) Rate(Acfm) Rectangle(L x W) (in 0.1 feet) F2 FUGITIVE (NO 1 72 Area= 1 Grain Receiving STACK) operating Scenario: OS -2 Emission Source/Group ID: ES-2 ). Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 ) 1.Typical Start& End Times For Operating Scenario: Start: 0 End: 2359 !. Seasonal Periods Percent Annual Throughput: an-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25% 020 1 2020 1 2020 1 2020 3. Actual Emissions per Pollutant Listed : ttach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG CAS GHG Estimation Efficiency Emission Ef Pollutants Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Pollutant Criteria Estimation Emission Ef (NAAQS) Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 CO CO 08 NOx NOx 08 TSP TSP 2.9 08 PM10 PM10 1.2 08 PM2.5 PM2.5 0.2 08 S02 S02 08 VOC V C 08 Emissions Emission Control HAP/TAP CAS Estimation Emission EF (Pounds/Year)Pollutants(In Alphabetical Order) (see instructions) RAP/TAPS Method Code (Net after all controls) Factor Control (See Instructions) 2020 COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 Emission Source ID(from permit) ES-2 or Emission Source Group ID Emission Source Description : Dump pit with a three-sided enclosure on one 15,000 bushels per hour receiving elevator leg Operating Scenario ID/ OS - 5/Grain drying Description: SCC Number/Description: 30200604/Feed and Grain Country Elevators ; Drying . Throughput/units in 2020: 42554 TON/yr (e.g.production or fuel use): Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) � Capture Efficiency (%of Emissions from this Process Vented to Control Device or Stack): Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) Information: Sources vented to more than one ERP use additional en lines): Emission Release Point(ERP) ( try ) :RP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter#): (F) (Feet/sec) Rate (Acfm) Rectangle(L x W) (in 0.1 feet) FUGITIVE (NO Grain Dryer F 1 STACK) 0.1 70 Area= 0 Fugitive operating Scenario: OS - 5 Emission Source/Group ID: ES-2 ). Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 ) 1.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359 !. Seasonal Periods Percent Annual Throughput: an-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25% 020 1 2020 1 2020 2020 3. Actual Emissions per Pollutant Listed : ttach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG CAS GHG Estimation Efficiency Emission Ef Pollutants Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Pollutant Criteria Estimation Emission Ef (NAAQS) Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 CO CO 08 NOx NOx 08 TSP TSP 4.6 08 PM10 PM10 1.1 08 PM2.5 PM2.5 0.2 08 S02 S02 08 VOC VOC 08 Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants(In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control (Pounds/Year) Method Code (Net after all controls) (See Instructions) 2020 COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 Emission Source ID (from permit) ES-3 or Emission Source Group ID Emission Source Description : 7,000 bushels per hour shipping elevator leg with two loadout chutes Operating Scenario ID/ OS - 3/Grain loadout for trucks Description: SCC Number/Description: 30200606/Feed and Grain Country Elevators ; Loading (Shipping) Throughput/units in 2020: 13655 TON/yr (e.g.production or fuel use): Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) Capture Efficiency (%of Emissions from this Process Vented to Control Device or Stack): Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): :RP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle Rectangle(enter X): (F) (Feet/sec) Rate(Acfm) (1 (in 0.1 feet) F3 FUGITIVE (NO 1 72 Area= 1 Grain Loadout STACK) iperating Scenario: OS - 3 Emission Source/Group ID: ES-3 ). Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 ) 1. Typical Start& End Times For Operating Scenario: Start: 0 End: 2359 L Seasonal Periods Percent Annual Throughput: an-Feb +Dec o March-May o June-Aug. o Sept:Nov. o 020 25/0 2020 25/0 2020 25/0 2020 25/o 3. Actual Emissions per Pollutant Listed : ttach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG CAS GHG Estimation Efficiency Emission Ef Pollutants Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Pollutant Criteria Estimation Emission Ef (NAAQS) Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 CO CO 08 NOx NOx 08 TSP TSP 0.58 08 PM10 PM10 0.19 08 PM2.5 PM2.5 0.03 08 S02 S02 08 VOC VOC 08 Emissions Emission Control HAP/TAP CAS Estimation Emission EF see instructions HAP/TAPS Efficiency Pollutants(In Alphabetical Order) ( > Method Code y Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2020 COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 Emission Source ID(from permit) ES-4 or Emission Source Group ID Emission Source Description : Rail/truck loadout spout Operating Scenario ID/ OS -4/Grain loadout for railcars Description: SCC Number/Description: 30200606/Feed and Grain Country Elevators ; Loading (Shipping) Throughput/units in 2020: 31372 TON/yr (e.g.production or fuel use): Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) _l I Capture Efficiency (%of Emissions from this Process Vented to Control Device or Stack): Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) Emission Release Point(EPP) Information: (Sources vented to more than one ERP use additional entry lines): :RP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm) Rectangle(L x W) (in 0.1 feet) F4 FUGITIVE (NO 1 72 Area= 1 Rail Loadout STACK) 1perating Scenario: OS - 4 Emission Source/Group ID: ES-4 ). Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 ) I. Typical Start& End Times For Operating Scenario: Start: 0 End: 2359 !. Seasonal Periods Percent Annual Throughput: + jJune-Aug. Sept.-Nov.an-Feb Dec 25% March-May 25% 25% 25% 020 2020 2020 2020 _T 3. Actual Emissions per Pollutant Listed : ttach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG CAS GHG Estimation EfficiencyEmission Ef nt et after Factor Control Pollutants M Pollutants Method Code (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Pollutant Criteria Estimation Emission Ef Efficiency AA S Y Q Code (Net after Factor Control Pollutants Pollutants Method Code (Tons/Year) (See Instructions) all controls) 2020 CO CO 08 NOx NOx 08 TSP TSP 0.42 08 PM10 PM10 0.03 08 PM2.5 PM2.5 0.01 08 S02 S02 08 VOC VOC 08 Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants(In Alphabetical Order) (see instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2020 COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 Emission Source ID(from permit) ES-5 or Emission Source Group ID Emission Source Description : 4,700 bushels per hour Zimmerman grain dryer(propane-fired, 46 million Btu per hour maximum heat input) Operating Scenario ID/ OS - 7/Wet leg to grain dryer and from grain dryer to storage. Description: SCC Number/Description: Not required by facility, will be completed by DAQ Throughput/units in 2020: 82786 GAL/yr (e.g.production or fuel use): Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) . Capture Efficiency (%of Emissions from this Process Vented to Control Device or Stack): Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): :RP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter#): (F) (Feet/see) Rate (Acfm) Rectangle(L x W) (in 0.1 feet) F5 FUGITIVE (NO 1 72 Area= 1 Grain Dryer STACK) I Fugitive ►perating Scenario: OS - 7 Emission Source/Group ID: ES-5 ). Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 ) 1. Typical Start& End Times For Operating Scenario: Start: 0 End: 2359 1. Seasonal Periods Percent Annual Throughput: an-Feb+Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25% 020 1 2020 1 2020 1 2020 3. Actual Emissions per Pollutant Listed : ttach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG CAS GHG Estimation Efficiency Emission Ef Pollutants Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Pollutant Criteria Estimation Emission Ef (NAAQS) Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 CO CO 0.31 08 NOx NOx 0.54 08 TSP TSP 0 08 PM10 PM10 0 08 PM2.5 PM2.5 0 08 S02 S02 0 08 VOC VOC 0.04 08 Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants (In Alphabetical order) (See instructions) HAP/TAPS Method Efficiency Factor Control (Pounds/Year) Mod Code (Net after all controls) (See Instructions) 2020 COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 Emission Source ID(from permit) I-ES-BV or Emission Source Group ID Emission Source Description : Bin Vents Operating Scenario ID/ OS - 6/13in Loading Vents Description: SCC Number/Description: 30200605/Feed and Grain Country Elevators ; Unloading (Receiving) Throughput/units in 2020: 53568 TON/yr (e.g.production or fuel use): Fuel Information %Sulfur %Ash Heat Content (If fuel is used) (Btu/units) Capture Efficiency (%of Emissions from this Process Vented to Control Device or Stack): Control Device Information :None Order CS-ID CD ID Control Device Description (as listed in permit) Emission Release Point(ERP) Information: (Sources vented to more than one ERP use additional entry lines): :RP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description (in feet) Circle(enter#): (F) (Feet/sec) Rate(Acfm) Rectangle(L x W) (in 0.1 feet) FUGITIVE (NO Grain Dryer F1 STACK) 0.1 70 Area=0 Fugitive operating Scenario: OS - 6 Emission Source/Group ID: I-ES-BV ). Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2020) Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 ) 1. Typical Start& End Times For Operating Scenario: Start: 0 End: 2359 !. Seasonal Periods Percent Annual Throughput: an-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25% 020 1 2020 1 2020 1 2020 3. Actual Emissions per Pollutant Listed : ttach calculations and documentation of emission factors or other estimation methods used. Emissions- Emission Control GHG CAS GHG Estimation Efficiency Emission Ef Pollutants Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 Criteria Emissions- Emission Control Pollutant Criteria Estimation Emission Ef (NAAQS) Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control (Tons/Year) (See Instructions) all controls) 2020 CO CO 08 NOx NOx 08 TSP TSP 0.66 08 PM10 PM10 0.16 08 PM2.5 PM2.5 0.02 08 S02 S02 08 VOC VOC 08 Emissions Emission Control HAP/TAP CAS Estimation Emission EF Pollutants(In Alphabetical Order) (see instructions) HAP/TAPS Method Code Efficiency Factor Control (Pounds/Year) (Net after all controls) (See Instructions) 2020 acility Total CY 2020 Emissions Summary COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO North Carolina Department of Environmental Quality Division of Air Quality Air Pollutant Point Source Emissions Inventory- Calendar Year 2020 ecord Facility-Wide Totals From all Permitted and Non-Permitted AirPollutant Emission Sources reen House Gases Pollutants GHG Actual Emissions(Tons/Year) 'ollutant I CAS 12020 12013 % Change riteria Pollutants Actual Emissions(Tons/Year) 'ollutant CAS 2020 2013 %Change 10 CO 0.31 .28 10.714286% lox NOx 0.54 .25 116.00001% M(TSP) TSP 9.16 11.06 -17.179028% M 10 PM 10 2.68 2.93 -8.532423% M2.5 PM2.5 0.46 .52 -11.538457% 02 S02 0.0 Not reported I N/A 'OC VOC 0.04 .04 10.0% azardous Air Pollutants HAPS and/or Toxic Air Pollutants TAPs Actual Emissions(Pounds/Year) 'ollutant I CAS 12020 12013 1%Change COPY of RECORD Date Submitted: 12/17/2021 11:01:23 As entered in AERO acility Name: Perdue Grain and Oilseed, LLC - Pantego Facility ID : 0700070 1461 Swindell Road Permit : 03107 Pantego,NC 28760 County : Beaufort DAQ Region : WARO 'omments From Facility: 12122/21, 11:04 AM NC DAQ-EMISSIONS INVENTORY Facility Total CY 2020 Emission Summary Facility Id : 0700070 Green House Gases Pollutants GHG Actual Emissions Tons/Year) Pollutant CAS 1 2020 1 2013 %Change Criteria Pollutants Actual Emissions Tons/Year) Pollutant CAS 2020 2013 %Change CO CO 0.31 .28 10.714286% NOx NOx 0.54 .25 116.00001% PM TSP TSP 9.16 11.06 -17.179028% PM 10 PM 10 2.68 2.93 -8.532423% PM2.5 PM2.5 0.46 .52 -11.538457% S02 S02 0.0 Not reported N/A VOc VOC 0.04 .04 0.0% Hazardous Air Pollutants HAPS and/or Toxic Air Pollutants(TAPs) Actual Emissions Pounds/Year Pollutant CAS 2020 1 2013 %Change close https://xapps.ncdenr.org/aq/aero/EDFacTotals.jsp 1/1 Emissions by Operating Scenario for Pollutant 2020 Inventory acility Name: Perdue Grain and Oilseed, LLC - Pantego acility ID : 0700070 Permit : 03107 Process ID Operating Scenario Emission Rate(Tons/Yr) Emission Source ID 'O Grain receiving ES-2 Bin Loading Vents I-ES-BV Wet leg to grain dryer and from grain dryer to storage. .31 ES-5 Grain loadout for trucks ES-3 Grain drying ES-2 Wet leg to grain dryer and from dryer to storage ES-1 Grain loadout for railcars ES-4 TOx Grain receiving ES-2 Bin Loading Vents I-ES-BV Grain loadout for trucks ES-3 Grain drying ES-2 Wet leg to grain dryer and from grain dryer to storage. .54 ES-5 Wet leg to grain dryer and from dryer to storage ES-1 Grain loadout for railcars ES-4 'M(TSP) Wet leg to grain dryer and from grain dryer to storage. 0 ES-5 Grain loadout for railcars .42 ES-4 Grain drying 4.6 ES-2 Bin Loading Vents .66 I-ES-BV Grain receiving 2.9 ES-2 Grain loadout for trucks .58 ES-3 Wet leg to grain dryer and from dryer to storage ES-1 'M10 Grain loadout for trucks .19 ES-3 Grain drying 1.1 ES-2 Wet leg to grain dryer and from grain dryer to storage. 0 ES-5 Grain receiving 1.2 ES-2 Grain loadout for railcars .03 ES-4 Bin Loading Vents .16 I-ES-BV Wet leg to grain dryer and from dryer to storage ES-1 M2.5 Grain receiving 1.2 1ES-2 Grain loadout for tninka I o3 FC-i Wet leg to grain dryer and from grain dryer to storage. 0 ES-5 Wet leg to grain dryer and from dryer to storage ES-1 Bin Loading Vents .02 I-ES-BV ,02 Grain receiving ES-2 Wet leg to grain dryer and from grain dryer to storage. 0 ES-5 Bin Loading Vents I-ES-BV Grain loadout for trucks ES-3 Grain drying ES-2 Wet leg to grain dryer and from dryer to storage ES-1 Grain loadout for railcars ES-4 70C Grain receiving ES-2 Bin Loading Vents I-ES-BV Grain loadout for trucks ES-3 Grain drying ES-2 Wet leg to grain dryer and from grain dryer to storage. .04 ES-5 Wet leg to grain dryer and from dryer to storage ES-1 Grain loadout for railcars ES-4 Process ID Operating Scenario I Emission Rate(lbs/Yr) Emission Source M