HomeMy WebLinkAboutAQ_F_1900015_20200630_EI_Cmb-EI-File 2019 Emissions Inventory Review / Data Tracking Form
Facility Name: Arauco North America Inc. Facility ID: 1900015
Facility Assigned to: Data Entry: Chatham County
Classification: Matthew Mahler Confidential Copy Submitted?
Title V ES
Initial Review/Data Entry
PEE ter date received into ED. Date Received:
lsd' Assigned to appropriate individual. Date Assigned: Date Due: 1 -1 5 " 2-uzo
O Paper copy submitted: One copy received with supporting documentation,certification form signed by responsible official,and
pears generally complete;OR
Electronic copy submitted: All supporting documentation and certification form(with time/date stamp)signed by responsible
official has been received.
Comments: C h 6k v, e, "A �' m :j .v hS 0 /a p,- eki P- -2Yc_ I uk.'fitoo S
c10C e'lte' X-PE-14MS ED 1 ..tc�not C�:" mP.i.fs SPe-iFroN •
Inventory Review
All forms and supporting documentation appear to be complete if paper submission(check ED OS data if electronic).
Contact,address,phone number changes entered into I-Beam/Facilities if necessary.
All known operating scenarios,control devices,and emission release points have been entered for each emission source(permitted,
_ .4nsignificant,and unpermitted)or note that the emission source was not operated or not required to report.
Ur if SCC codes for each OS are accurate and update if needed.
Evaluate"U"sources for significance and address according to policy.
,,,-Calculations/forms appear to add up correctly.
All compliance issues are being addressed(e.g.Toxics limits,above TV thresholds,large emissions increase/decrease,installation
L� without a permit).
All volatile HAPs/TAPS were included in the VOC total.
Calculations and control efficiencies appear correct. Emission factors are the best available and most current factors appropriate for
M--the reporting facility(e.g. stack testing,AP-42,etc.).
0,-Review facility comments and address any issues.
[a, f pdate ED(Data Entry Main)if additional information is required(corrections due date and date received).
Kheck all ED QA/QC reports.
omparison with previous emission inventory must be made and outliers(> 10%)must be investigated and explained.
Cr Put inventory review comments and summarize any changes in ED-Data Entry Main"DAQ internal comments".
Print and attach the facility total report.
Date Info Requested: Date Info Received: Total Da��ys//i�on Hold:
Date Review Complete: v -�5 -Zo 20 Signature: `�✓/c�t��'TG(�C_
Date Submitted to EI Coordinator: D 20 20
Date Approved: o 1-:50 Initials:
,.:Facility Total CY 2019 Emission Summary Recorded in ED Facility ID #: 1900015
Facility'Name: Arauco North America, Inc. Permit#(s): 03449T53
Green House Gases Pollutants (GHG) Actual Emissions
Tons/Yr
Pollutant CAS. Demini- Change
mus
Not Not N/A
Reported Reported
CO2 equivalent (sum of individual GHG pollutant emission No GHGs
times their.1995 IPCC Global Warming Potential (GWP), Reported
converted to metric tons)
Criteria Pollutants Actual Emissions
(Tons/Year)
Pollutant CAS CY 2019 CY 2018 Demini- %
from ED from Fees mus Change
CO CO 579.34 493.30 0.5 17.4%
NOx Nox 280.04 245.13 0.5 14.2%
PM(TSP) TSP 156.92 131.05 0.5 19.7%
PM10 PM10 156.92 130.56 0.5 20.2%
PM2.5 PM2.5 137.44 114.18 0.5 20.4%
S02 S02 13.61 13.75 0.5 -1.0%
VOC VOC 1,260.94 985.75 0.5 27.9%
Hazardous Air Pollutants (HAPs) Actual Emissions
and/or Toxic Air Pollutants (TAPs) (Pounds/Year)
Pollutant CAS CY 2019 CY 2018 Demini- %
from ED from Fees mus Change
Arsenic & Compounds (total mass of elementalAS, arsine and 0.297990 0.307040 0.01 -2.9%
all inorganic compounds)
Arsenic Compounds - Arsine gas (Component of AS 7784-42-1 Not 0.001100 0.01 N/A
Reported
Arsenic Unlisted Compounds - Specify Compound ASC-other 0.297990 0.305940 0.01 -2.6%
(Component of ASC)
Beryllium & compounds (Total mass) 0.012670 0.019210 1.0 -34.0%
Beryllium Metal (unreacted) (Component of BEC) 7440-41-7 0.012670 0.002910 1.0 N/A
Beryllium Unlisted Compounds - Specify Compounc BEC-Other 0.000000 0.016300 1.0 -100.0%
(Component of BEC)
Cadmium & compounds (total mass includes elemental metal) 0,439180 0,540130 0.1 -18.7016
10/28/2020 Page 1 of 4
,Facility Total CY 2019 Emission Summary Recorded in ED Facility ID #: 1900015
Facility Name: Arauco North America, Inc. Permit#(s): 03449T53
Hazardous Air Pollutants (HAPs) Actual Emissions
and/or Toxic Air Pollutants (TAPs) (Pounds/Year)
Pollutant CAS CY 2019 CY 2018 Demini- %
from ED from Fees mus. Change
Cadmium Metal, elemental, unreacted (Component c 7440-43-9 0.439180 6.534030 0.1 -17.8%
CDC)
Cadmium Unlisted Compounds Specify Compounc CDC-Other Not 0.006100 0.1 N/A
(Component of CDC) Reported
Chromium-All/Total(includes Chromium (VI) categories, 1.04 0.838210 0.1 24.1
metal and others)
Chromic acid (VI) (Component of'So1CR6 & CRC) 7738-94-5 1.04 0.002910 0.01 N/A
Chromium Unlisted Compounds - Specify Compoun CRC-Other Not 0.835300 0.1 N/A
(Component of CRC) Reported
Chromium (VI) Soluble Chromate Compounds (Component of 1.04 70.002910 0.01 N/A
CRC)
Chromic acid (VI) (Component of So1CR6 & CRC) 7738-94-5 1.04 0.002910 0.01 N/A
Cobalt& compounds 0.338860 0.296220 1,0 14.4%
Cobalt Unlisted Compounds - Specify Compound COC-other 0:338860 0.296220 1.0 14.4%
(Component of COC)
Manganese & compounds 23.90 20.48 10.0 16.7%
Manganese Unlisted Compounds - Specify Compoui MNC-Other 23.90 20.48 10.0 16.7%
(Component of MNC)
Mercury & Compounds-all total mass includes Hg Vapor 0.320970 0.312490 0.001 2.7%
Mercury Unlisted Compounds - Specify Compound HGC-other Not 0.001400 0.001 N/A
(Component-of HGC) Reported
Mercury, vapor (Component of HGC) 7439-97-6 0.320970 0.311090 0.001 3.2%
Nickel& Compounds, sum total mass includes elemental 2.38 2.55 1,0 -6.7%
Nickel metal (Component of NIC) 7440-02-0 2.38 2.54 1.0 -6.4%
Nickel Unlisted Compounds (Component of NIC - NIC-other Not 0.011700 1.0 N/A
Specify) Reported
Polycyclic Organic Matter (7 PAH Compounds for NIF) 1.09 0.901150 1.0 21.0%
Benzo(a)pyrene (Component of 83329/POMTV& 50-32-8 1,09 0.901150 1.0 20.4%
56553/7PAH)
10/28/2020 Page 2 of 4
Facility Total CY 2019 Emission Summary Recorded in ED Facility ID #: 1900015
Facility Name: Arauco North America; Inc. ;;Permit:#(s): 03449T53
A
Hazardous Air Pollutants.(HAPs) Actual Emissions
and/or Toxic Air Pollutants (TAPs) (Pounds/Year)
Pollutant CAS CY 2019 CY 2018 'Demini- %
from ED from Fees mus Change
Polycyclic Organic Matter (Specific Compounds from OAQPS 30.76 27.01 1.0 13.9%
or Tip
Benzo(a)pyrene (Component of 83329/POMTV & 50-32-8 1.09 0.901150 1.0 20.4%
56553/7PAH)
Naphthalene (Component of 83329/POMTV) 91-20-3 29.68 26.11 1.0 13.7%
Acetaldehyde 75-07-0 12,367.77 10,205.81 10.0 21.2%
Acrolein 107-02-8 2,279.33 1,870.33 10.0 21>9%
Benzene 71-43-2 165.73 141.49 1.0 17.1%
Bromine 7726-95-6 16.00 13.38 10.0 19.6%
Chlorine 7782-50-5 552.85 469.04 100.0 17.9%
Chromium (VI) & compounds CHROM6CPDS Not 0.159920 N/A
Reported
Cumene 98-82-8 1,618.62 1,268.90 100.0 127.6%
Ethylene dichloride (1,2-dichloroethane) 107-06-2 0.949000 1.30 1.0 1 -26.9%
Formaldehyde 50-00-0 45,013.93 37,893.93 10.0 18.8%
Hexachlorodibenzo-p-dioxin 1,2,3,6,7,8 57653-85-7 0.052000 0.072000 0.0000 1 -27.8%
Hexane, n- 110-54-3 586.96 581.93 100.0 1 0.9%
Hydrogen chloride (hydrochloric acid) 7647-01-0 1,099.37 932.13 100.0 17.9%
MEK (methyl ethyl ketone, 2-butanone) 78-93-3 1,812.45 1,542.72 100.0 17.5%
Methanol (methyl alcohol) 67-56-1 570,093.60 466,116.06 1,000.0 22.3%
Methyl chloride (chloromethane) 74-87-3 0.756000 1.04 1.0 1 -27.0%
Methylene chloride 75-09-2 245.45 207.80 1.0 18.1%
MIBK (methyl isobutyl ketone) 108-10-1 243.00 207.02 10.0 .17.4%
Phenol 108-95-2 19,265.53 18,058.63 100.0 6.7%
Phosphorus Metal, Yellow or White 7723-14-0 3.22 4.41 1.0 1 -27.0%
Polycyclic Organic Matter (Inc PAH, dioxins, etc. N- pOM 120.17 101.05 1.0 18.9%
& AP 42 historic)
Propionaldehyde 123-38-6 752.00 626.43 10.0 20.0%
10/28/2020 Page 3 of 4
Facility Total CY 2019 Emission Summary Recorded in ED Facility ID #: 1900015
Facility Name: Arauco North America, Inc. Permit#(s): 0344OT53
Hazardous Air Pollutants (HAPs) Actual Emissions
and/or Toxic Air Pollutants (TAPS) (Pounds/Year)
Pollutant CAS CY 2019 CY 2018 Demini- %
from ED from Fees mus Change
Toluene 108-88-3 187.27 185.07 100.0 1.2%
Vinyl chloride 75-01-4 0.602000 0.824000 0.1 -26.9%
Largest Individual HAP Methanol(methyl alcohol) 570,093.601W
Total HAP Emissions 654,656.59 lbs
Largest Individual CAP VOC 1,260.94 tons
Total CAP Emissions 2,290.85 tons
Total TAP Emissions 83,866.41 lbs
C
Total Aggregate 2,291.81 tons
Emissions
U`N`
&jell
DAO's Comments,Regarding Inventory.
DAQ accepted late submittal of hardcopies due to COVID-19 up until August 31. Deleted CS-35 for OS22 Fine Materials Transpor
and added newly created CS-57.Deleted CS-30 for OS25 Steinman sander for PB process and added newly created CS-58.Deleted
CS-31 for OS26 PB sanderdust transport for sander, and added new CS-59.Deleted CS-17 for OS28 Sander Filter Transpot for Filk
3545 and 3565, and added new CS-60.Deleted CS-16 for OS30 Surface Hammermill and Surface PZKR's, and added new CS-61.
Deleted,CS-50 for OS-50,and added new CS-62,per facility 8/4 email.Per 8/4 facility email,updated throughputs of OS3,51,56,
49. Recoded following compound forms to correct form per Brendan Davey email. Arsenic OS46,Berylium OS75/79,Cadmium C
Chromium OS3/75,Mercury OS46,Nickel OS46. For OS51 Energy System, changed VOC from 933.80 tpy to 0.28 tpy,since the 9=
tpy value is the VOC emissions for ES-02-B(two stage dryer) instead of ES-02-A(Energy System assigned to OS51). Changes in
emissions that are greater than 10%between 2018 and 2019 inventories are explained as follows. Most Criteria pollutants,
HAPS/TAPS emission increases were due to either or both an 8%increase in hours of usage of the MDF Plant two-stage wood
dryer ES-02-B in OS69 and a 17%increase in throughput of the PB Plants drum dryer with burner,ESID 1420 in OS3. In additior.
OS3, PM/PMI O/PM2.5 emission increases were also due to an 8%increase in fuel use in ES-02-A Wood Burning in Energy Plant.
Cadmium emission decrease was due to an 89%reduction in natural gas burned in the Wellons Bypass for PB process,ESID 3201,
OS36. Hexachlorodibenzo-p-dioxin 1,2,3,6,7,8,Phosphorus Metal,and vinyl chloride emission decreases were due to a 27%
decrease in fuel use for OS75,ESID ES-02-A Energy System Bypass Mode. Other pollutants with a greater than 10%change were
below the de minimus.
10/28/2020 Page 4 of 4
a
DAQ's Comments Regarding Inventory
DAQ accepted late submittal of hardcopies due to COVID-19 up until August 31. Deleted CS-35 for OS22 Fine Materials Transport
and added newly created CS-57. Deleted CS-30 for OS25 Steinman sander for PB process and added newly created CS-58.Deleted
CS-31 for OS26 PB sanderdust transport for sander, and added new CS-59.Deleted CS-17 for OS28 Sander Filter Transpot for Filters
3545 and 3565, and added new CS-60. Deleted CS-16 for OS30 Surface Hammermill and Surface PZKR's,and added new CS-61.
Deleted CS-50 for OS-50, and added new CS-62,per facility 8/4 email. Per 8/4 facility email,updated throughputs of OS3,51,56, and
49. Recoded following compound forms to correct form per Brendan Davey email. Arsenic OS46,Berylium OS75/79, Cadmium OS46,
Chromium OS3/75,Mercury OS46,Nickel OS46.For OS51 Energy System, changed VOC from 933.80 tpy to 0.28 tpy,since the 933.80
tpy value is the VOC emissions for ES-02-B (two stage dryer)instead of ES-02-A(Energy System assigned to OS51). Changes in
emissions that are greater than 10%between 2018 and 2019 inventories are explained as follows. Most Criteria pollutants,
HAPS/TAPS emission increases were due to either or both an 8%increase in hours of usage of the MDF Plant two-stage wood
dryer ES-02-B in OS69 and a 17% increase in throughput of the PB Plants drum dryer with burner,ESID 1420 in OS3. In addition to
OS3,PM/PM I O/PM2.5 emission increases were also due to an 8%increase in fuel use in ES-02-A Wood Burning in Energy Plant.
Cadmium emission decrease was due to an 89%reduction in natural gas burned in the Wellons Bypass for-PB process,ESID 3201,
OS36. Hexachlorodibenzo-p-dioxin 1,2,3,6,7,8,Phosphorus Metal,and vinyl chloride emission decreases were due to a 27%
decrease in fuel use for OS75, ESID ES-02-A Energy System Bypass Mode. Other pollutants with a greater than 10%change were
below the de minimus.
10/218/2020 Page 1 of 4
9472020 Mail-Mahler,Matthew-Outlook
[External] RE: 2019 Emission Inventory submittal for Arauco North America-Moncure
(FID # 1900015)
Savannah Carroll <savannah.carroll@arauco.com>
Tue 8/4/2020 11:24 AM
To: Mahler, Matthew<matthew.mahler@ncdenr.gov>
CAUTION: External email. Do not click links or open attachments unless you verify.Send all suspicious email as an attachment
to repart.spam@nc.gov
Matt,
My apologies for any confusion or lack of clarity on items in the 2019 Emissions Inventory—I came onsite from
one of our SC facilities in April so I may have a little catching up to do in regards to NC Emissions inventory
inputting. Here are responses to your questions below:
1. For several operating scenarios (OS), are the following 2019 throughputs correct? I ask, because
the 2018-2019 actual throughputs are either identical numerical values or the values are orders-
of-magnitude in difference.
Operating 2018 Throughput 2019 Throughput Response
I Scenario
I This is a typo—I had entered an
OS3 118,149 sqft x 1000 38,792 q x m3 production value instead of
annual sqft prod. value
This is correct. The resin tanks are
not required to be controlled and
OS78 8736 hours 8736 the tanks stay full except for one
24 hour period every year for
maintenance
I incorrectly inputted the energy
OS51 487,379 MMBtu 522,509 MM to system abort throughput instead
of total system throughput
(minus abort)
16 ;205 s x This is a typo—I had entered an
OS56 151,449 sqft x 1000 / 1000 m3 production value instead of
I_ _ _ ✓ annual sqft prod. value
( - This is a typo—I had entered an
OS49 151,449 sqft x 1000 �'6 f 1000 x m3 production value instead of
annual sqft prod. value
Our accounting dept. did not
have a total gasoline usage
OS41 7991 gal 7991 gal response by due date, so this was
an estimation based on previous
usage.
2. There appears to be no operating scenario where Emission Source ID 3201 "Wellons" operating as
a natural gas-fired burner, is exhausting to CD-1431 and/or CD-1421 and CD-PB-WESP, as listed in
your air permit. Why is that? Exhaust from this source goes through the PB dryers and Wet ESP
(CD-1431 and/or CD-1421 and CD-PB-WESP). However, during startup, the exhaust is bypassed to
atmosphere. The emissions are counted in the.dryers exhaust except startup. Startup emissions
are accounted for in this calculation. From what I can find in our historical submissions, this has
been calculated this way since 2007.
httl)s://outlook.office365.com/mail/inbox/id/AAQkAGU4NDE5ZjBiLWY50GQtNGM INS IhYmY4LTE5NzUzYWY40W120QAQALbnEr3ogq 1 LgTPGru6k5Qk%... 1/4
F-W2020 • Mail-Mahler,Matthew-Outlook
�3 For Operating Scenario OS74, Refiner Start Cyclone, (ES ID No. ES-01, Refiner) should there be a
control device CD-01 Refiner Abort'Cyclone associated with this OS and thus added?The name
"Refiner Start Cyclone" may be misleading as this cyclone is the start up and abort cyclone—to be
more accurate, it captures emissions from both start up and shut down scenarios, captured in the
calculation. The calculation is determined in our systems by when we are aborting to this
particular cyclone—whether during start up or shut down. The control device is the same for both.
4. For Operating Scenario OS-50, I deleted the outdated Control System CS-50 (Control Devices CD-
02, CD-14). I want to add a new Control System for this Operating Scenario. To match what's
listed in your facility's air permit, ...should I add a new updated Control System which includes CD-
01, CD-02, CD-14 and CD-18... OR.... only CD-02, CD-14, and CD-18? I would say CD-02, CD-14, and
CD-18. Though CD-01 is in fact part of the refining control system,the operating scenario in which
we use it, and the emissions associated with that, are captured separately (as highlighted in
question 4). CD-01 is only utilized in a start-up/shutdown/upset situation, and not routinely in
normal refining operations, which I believe is what OS-50 previously described.
I do also want to mention that our facility is currently operating under an SOC as a result of not
capturing 100%of emissions to the biofilter(CD-18). I mention this because if the operating
scenario is altered for 2019 to include CD-18,this would not be accurate, as the emissions were
captured through the operating scenario as is, NOT as they are stated in the permit. We are
working towards resolution of this SOC and'performance testing on CD-18
Again, my apologies for the inaccuracies regarding your first question, I will be certain to review carefully
going forward. Please let me know if you having any questions or concerns regarding this information!
The best number to reach me at is 843-544-3025 or my email.
Thank you,
( Savannah Carroll
arauAdolk Environmental Manager
q 985 Corinth Rd.,Moncure,NC 27559
Phone:(919)545-5848 Mobile:(843)544-3025
www.arauco-na.com
From: Mahler, Matthew
Sent: Monday,August 3, 2020 4:18 PM
To:Savannah Carroll
Subject: Re: 2019 Emission Inventory submittal for Arauco North America-Moncure (FID#1900015)
Advertencia:Este es un correo externo.No abra/descargue archivos desconocidos;no haga clic en enlaces sin antes verificar la
procedencia de los correos.
Hi Savannah,
I'm in the process of reviewing your facility's 2019 Emissions Inventory. I have a few questions that I
thought you may be able to help me with. I'm listing them below.
5. For several operating scenarios (OS) , are the following 2019 throughputs correct? I ask, because
the 2018-2019 actual throughputs are either identical numerical values or the values are orders-
of-magnitude in difference.
Operating 2018 Throughput 2019 Throughput
Scenario
https://outlook.office365.com/mail/inbox/id/AAQkAGU4NDE5ZjBiLWY50GQtNGMINS1 hYmY4LTE5NzUzYWY40W]20QAOALbnEr3ogq 1 LgTPGru6k5Qk%... 2/4
6W2020 Mail-Mahler,Matthew-Outlook
OS3 118,149 sqft x 1000 100
OS78 8736 hours 8736
OS51 497,379 MMBtu 32,720
OS56 151,449 sqft x 1000 114
OS49 151,449,sgft x 1000 151,449
v OS41 7991 gal 7991 gal
6.
7.There appears to be no operating scenario where Emission Source ID 3201 "Wellons" operating as
a natural gas-fired burner, is exhausting to CD-1431 and/or CD-1421 and CD-PB-WESP, as listed in
your air permit. Why is that?
8. For Operating Scenario OS74, Refiner Start Cyclone, (ES ID No. ES-01, Refiner) should there be a
control device CD-01 Refiner Abort Cyclone associated with this OS and thus added?
9. For Operating Scenario OS-50, I deleted the outdated Control System CS-50 (Control Devices CD-
02, CD-14). I want to add a new Control System for this Operating Scenario. To match what's
listed in your facility's air permit, ...should I add a new updated Control System which includes CD-
01, CD-02, CD-14 and CD-18... OR.... only CD-02, CD-14, and CD-18?
Thank you for looking over these few items above. If you have any questions and would like to chat,
please call me at 919-578-3122.
Best Regards,
Matt
Matthew Mahler, Engineer
Raleigh Regional Office
NC DENR, Division of Air Quality
3800 Barrett Drive, Raleigh, NC 27609
Google Cell: 919-578-3122
RRO Mainline Phone: (919) 791-4200
Fax: (919) 881-2261
www.ncair.org
matthew.mahler@ncdenr.gov
E-mail correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third
parties unless the content is exempt by statute or other regulation.
From: Mahler, Matthew
Sent: Monday,July 20,202010:13 AM
To:savannah.carroll@arauco.com<savannah.carroll@arauco.com>
Subject:2019 Emission Inventory submittal for Arauco North America-Moncure (FID#1900015)
Hi Savannah,
I left a voicemail but thought that I should follow.up with an email, as well. Our office received your
facility's 2019 Emission Inventory hardcopy recently. I'm the engineer assigned to review and verify the
emission calculations of the Inventory.
Your facility's submittal included the signed Certification Form, and the AERO printout. However, no
emission calculation spreadsheets were included. In past Inventory years, your facility has provided the
hardcopy calculation sheets to aid with my Inventory review. Would you please email the full set of
https://outlook.office365.com/mail/inbox/id/AAQkAGU4NDE5ZjBiLWY50GQtNGMINS IhYmY4LTE5NzUzYWY40WI20QAQALbnEr3ogglLgTPGru6k5Qk%... 3/4
64/2020 Mail-Mahler,Matthew-Outlook
operating scenario and emission calculations spreadsheets, pollutant total sheets, material throughput
sheets, and any other data sheets that would help me to review and verify your facility's 2019 Emission
Inventory?
If you have any questions about my request or what has been submitted in the prior Inventory years,
please feel free to call me at 919-578-3122.
Best Regards,
Matt
Matthew Mahler, Engineer
Raleigh Regional Office
NC DENR, Division of Air Quality
3800 Barrett Drive, Raleigh, NC 27609
Google Cell: 919-578-3122
RRO Mainline Phone: (919) 791-4200
Fax: (919) 881-2261
www.ncair.org
matthew.mahler@ncdenr.gov
E-mail correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third
parties unless the content is exempt by statute or other regulation..
https://outlook.office365.com/mail/inbox/id/AAQkAGU4NDE5ZiBiLWY50GQtNGMINS IhYmY4LTE5NzUzYWY40WI20QAQALbnEr3ogq 1 LgTPGru6k5Qk%... 4/4
Facility Total CY 2019 Emission Summary Recorded in ED Facility ID#: 1900015
Facility Name: Arauco North America,Inc. Permit#(s): 03449T53
Green House Gases Pollutants(GHG) Actual Emissions "�o
Tons/Yr
_
Pollutant CASDemini- Change
mus
Not Not N/A
Reported Reported
CO2 equivalent(sum of individual GHG pollutant emigsior No GHGs
times their 1995 IPCC Global Warming Potential(GWP), Reported
converted to metric tons)
Criteria Pollutants Actual F► :
Pollulant CAS 1 .Qir� nini-
t Change US
I�+s
CO CO f 17.4%
NOx NOx
PM(TSP) TSP
PM10 PMIO 15 Q,� �L TO.211:;
PM2.5 PM2.5 13 114.18 0.5 20.4%
S02 SO2 13.61 13.75 0.5 -1.0%
VOC VOU 2,194.46 985.75 0.5 122.60/t,
Hazardous Air Pollutants(HAPs) Actual Emissions
and/or Toxic Air Pollutants(TAPs) (Pounds/Year)
Pollutant CAS CY 2019 CY 2018 Demini- %
from ED from Fees mus Change
Arsenic& Compounds(total mass of elemental AS, ursine and 0.297990 0.307040 0.01 -2.9%
all inorganic compounds)
Arsenic Compounds-Arsine gas(Component of AS 7784-42-1 Not 0.001100 0.01 N/,",
Reported
Arsenic Unlisted Compounds- Specify Compound ASC-Other 0.297990 0.305940 0.01 -2.6%
(Component of ASC)
Beryllium & compounds(Total mass) 0.012670 0.019210 1.0 -34.0%
Beryllium Metal(unreacted) (Component of BEC) 7440-41_7 0.012670 0.002910 1.0 N/A
Beryllium Unlisted Compounds- Specify Compount BEC-Other 0.000000 0.016300 1.0 -100.00/0
(Component of BEC)
Cadmium& compounds(total mass includes elemental metal) 0.439180 0.540130 0.1 I -18.7%
10/15/2020 Pagc I o t'4
Facility Total CY 2019 Emission Summary Recorded in ED Facility ID#: 1900015
Y
Facility Name: Arauco North America,Inc. Permit#(s): 03449T53
Hazardous Air Pollutants (HAPs) Actual Emissions
and/or Toxic Air Pollutants (TAPs) (Pounds/Year)
Pollutant CAS CY 2019 CY 2018 Demini- %
- from'ED _from Fees mus" �� b
Cadmium Metal, elemental,unreacted(Component c 7440-43-9 0.439180 0.534030 0.1 -17.8%
CDC)
Cadmium Unlisted Compounds - Specify Compounc CDC-Other Not 0.006100 0.1 N/A
(Component of CDC) Reported
Chromium-All/Total(includes Chromium (VI) categories, 1.04 0.838210 0,1 124.1%
metal and others)
Chromic acid(VI) (Component of So1CR6&CRC) 7738-94-5 1.04 0.002910 0.01 N/A
Chromium Unlisted Compounds- Specify Compoun CRC-Other Not 0.835300 0.1 N/A
(Component of CRC) Reported
Chromium(VI)Soluble Chromate Compounds(Component of 1.04 0*002910 0.01 N/A
CRC)
[Chromic acid(VI) (Component of So1CR6 &CRC) 7738-94-5 1.04 0.002910 0.01 N/A
Cobalt& compounds 0.338860 0.296220 1,0 14.4%
Cobalt Unlisted Compounds- Specify Compound CoC-Other 0.338860 0.296220 1.0 14.4%
(Component of COC)
Manganese& compounds 23.90 20.48 10.0 16.7%
Manganese Unlisted Compounds- Specify Compom MNC-Other 23.90 20.48 10.0 .1.6.7%►
(Component of MNC)
Mercury& Compounds-all total mass includes Hg Vapor 0.320970 0.312490 0.001 2.7%
Mercury Unlisted Compounds- Specify Compound HGC-other Not 0.001400 0.001 N/A
(Component of HGC) Reported
Mercury,vapor(Component of HGC) 7439-97-6 0.320970 0.311090 0.001 3.2%
iNickel& Compounds,sum total mass includes elemental 2.38 I 2.55 I 1.0 i -6.7% i
Nickel metal(Component of NIC) 7440-02-0 2.38 2.54 1.0 -6.4%
Nickel Unlisted Compounds(Component of NIC- NIC-other Not 0.011700 1.0 N/A
Specify) Reported
Polycyclic Organic Matter(7 PAH Compounds for NIF) 1.09 0.901150 1.0 21.0%
Benzo(a)pyrene(Component of 83329/POMTV& 50-32-8 1.09 0.901150 1.0 20.4%
56553/7PAH)
10/15/2020 Page 2 of 4
Facility Total CY 2019 Emission Summary Recorded in ED Facility ID#: 1900015
Facility Name: Arauco North America,Inc. Permit#(s): 03449153
Hazardous Air Pollutants(HAPs) Actual Emissions
and/or Toxic Air Pollutants (TAPS) (Pounds/Year)
Pollutant CAS CY 2019 CY 2018 Demini- %
from ED from Fees mus Change
Polycyclic Organic Matter(Specific Compounds from OAQPS 30.76 27.01 1.0 13.9%
or TV)
Benzo(a)pyrene (Component of 83329/POMTV& 50-32-8 1.09 0.901150 1.0 20.4%
56553/7PAH)
Naphthalene(Component of 83329/POMTV) 91-20-3 29.68 26.11 1.0 13.7%
Acetaldehyde 75-07-0 12,367.77 10,205.81 10.0 21.2%
Acrolein 107-02-8 27279.33 1,870.33 10.0 21.9%
Benzene 71-43-2 165.73 141.49 1.0 1.7.1.%
Bromine 7726-95-6 16.00 13.38 10.0 11.9.6%
Chlorine 7782-50-5 552.85 469.04 100.0 17.9%
Chromium(VI)&compounds CHROM6CPDS Not 0.159920 N/A
Reported
Cumene 98-82-8 1,618.62 1,268.90 100.0 27.6%
Ethylene dichloride(1,2-dichloroethane) 107-06-2 0.949000 1.30 1.0 -26.9%,
Formaldehyde 50-00-0 45,013.93 37,893.93 10.0 1 1.8.8%
Hexachlorodibenzo-p-dioxin 172,376,7,8 57653-85-7 0.052000 0.072000 0.0000 -27.8%
Hexane,n- 110-54-3 586.96 581.93 100.0 0.9%
Hydrogen chloride(hydrochloric acid) 7647-01-0 1,099.37 932.13 100.0 17.9%
n1 ca ne; _7&-:93-3
T. kIlIcy .thyl_ 1,811 2.4J l,SA4G...72 I1OVU N
I af. io
Methanol(methyl alcohol) 67-56-1 570,093.60 466,116.06 1,000.0 22.3%
Methyl chloride(chloromethane) 74-87-3 0.756000 1.04 1.0 -27.0%
Methylene chloride 75-09-2 245.45 207.80 1.0 .1.8.1%,
MIBK(methyl isobutyl ketone) 108-10-1 243.00 207.02 10.0 17.4%
Phenol 108-95-2 19,265.53 18,058.63 100.0 6.7%
Phosphorus Metal, Yellow or White 7723-14-0 3.22 4.41 1.0 -27.0%►
Polycyclic Organic Matter(Inc PAH,dioxins,etc.N- pOM 120.17 101.05 1.0 18.9%
&AP 42 historic)
Propionaldehyde 123-38-6 752.00 626.43 10.0 20.0%,
10/15/2020 Page 3 of 4
v aciiiiy iuiai CY-2019 emission Summary-Recordedin ED r acilky ID#: i 7uvui 3
Facility Name: Arauco North America,Inc. Permit#(s): 03449T53
Hazardous Air Pollutants(HAPs) Actual Emissions
and/or Toxic Air Pollutants(TAPs) (Pounds/Year)
Pollutant CAS CY 2019 CY 2018 Demini- %
from ED from Fees mus Change
Toluene 108-88-3 187.27 185.07 100.0 1.2%
Vinyl chloride 75-01-4 0.602000 0.824000 0.1 1-26.9%
Largest Individual HAP Methanol(methyl alcohol) 570,093.60 lbs
Total HAP Emissions 654,656.59 lbs
Largest Individual CAP VOC 2,194.46 tons
Total CAP Emissions 3,224.37 tons
Total TAP Emissions 83,866.41 lbs
Total Aggregate 3,225.33 tons
Emissions
DAQ's Comments Retarding Inventory
DAQ accepted late submittal of hardcopies due to COVID-19 up until August 31. Deleted CS-35 for OS22 Fine Materials Transpor
&iu aiueu.t newly ireaied`CS-J 7.....L;leieu%J=30'fUr'OJZJ"Sie11iaC sander for PB processs-81i added newly-created b 1ClCicu
CS-31 for OS26 PB sanderdust transport for sander,and added new CS-59.Deleted CS-17 for OS28 Sander Filter Transpot for Filte
3545 and 3565,and added new CS-60.Deleted CS-16 for OS30 Surface Hammermill and Surface PZKR's,and added new CS-61.
Deleted CS-50 for OS-50,and added new CS-62,per facility 8/4 email.Per 8/4 facility email,updated throughputs of OS3,51,56,
49. Recoded following compound forms to correct form per Brendan Davey email. Arsenic OS46,Berylium OS75/79,Cadmium C
Chromium OS3/75,Mercury OS46,Nickel OS46. Changes in emissions that are greater than 10%between 2018 and 2019 inventori
are explained as follows. Most Criteria pollutants,HAPS/TAPS emission increases were due to either or both an 8%increase in
hours of usage of the MDF Plant two-stage wood dryer ES-02-B in OS69 and a 17%increase in throughput of the PB Plants drum
dryer with burner,ESID 1420 in OS3. In addition to OS3,PM/PM I O/PM2.5 emission increases were also due to an 8%increase in
fuel use in ES-02-A Wood Burning in Energy Plant. Cadmium emission decrease was due to an 89%reduction in natural gas burner
in the Wellons Bypass for PB process,ESID 3201,OS36. Hexachlorodibenzo-p-dioxin 1,2,3,6,7,8,Phosphorus Metal,and vinyl
chloride emission decreases were due to a 27%decrease in fuel use for OS75,ESID ES-02-A Energy System Bypass Mode. Other
pollutants with a greater than 10%change were below the de minimus.
10/15/2020 Page 4 of 4
Arauco North America,Inc. Facility ID: 1900015
985 Corinth Road Permit:03449
Moncure,:`TC 27559 County:Chatham
Inventory Year:2019 DAQ Region:RRO
Emission Source & Operating Scenario List
Group ID Group Description ES ID Emission Source Description OS ID OS Description
G-126 Refiner[PSD,MACT ES-01 Refiner[PSD,MACT Subpart DDDD] 50 Refiners
Subpart DDDD]
ES-01 Refiner[PSD,MACT Subpart DDDD] 74 Refiner Startup Cyclone
G-128 Energy System consisting ES-02-A Energy System consisting of one dry/wet wood/ 51 Wood Burning in Energy Plant
of one dry/wet wood/ woodwaste-fired burner(205 million Btu per hour heat
woodwaste-fired burner input)[PSD,MACT Subpart DDDD]
(205 million Btu per hour
heat input)[PSD,MACT
Subpart DDDD]
ES-02-A Energy System consisting of one dry/wet wood/ 75 Energy System Bypass Mode
woodwaste-fired burner(205 million Btu per hour heat (25MMBtu/hr)
input)[PSD,MACT Subpart DDDD]
G-129 Two Stage Dryer System ES-02-B Two Stage Dryer System[PSD,MACT Subpart DDDD] 69 Two Stage Dryer System-Wood
[PSD,MACT Subpart Drying
DDDD]
G-132 MDF Press[PSD,MACT ES-16 MDF Press and Press Hall[PSD,MACT Subpart DDDD] 49 Scrubber controlling press
Subpart DDDD]
G-133 MDF Board Cooler and ES-06-B MDF Board Cooler and Press Hall[PSD,MACT Subpart 56 MDF Board Cooler
Press Hall[PSD,MACT DDDD]
Subpart DDDD]
G-134 Fiber Sifter System[PSD, ES-03 Fiber Sifter System[PSD,MACT Subpart DDDD] 53 Fiber Sifter System
MACT Subpart DDDD]
G-135 Forming Line Clean-Up ES-04 Forming Line Clean-Up System[PSD,MACT Subpart 54 Forming Line Clean-Up System
System[PSD,MACT DDDD]
Subpart DDDD]
G-136 Mat Reject System'PSD, ES-05 Mat Reject System[PSD,MACT Subpart DDDD] 55 Mat Reject System
MACT Subpart DDDD]
G-137 Saw System[PSD,MACT ES-07 Saw System[PSD,MACT Subpart DDDD] 57 Saw System Filter
Subpart DDDD]
G-138 Sander System No.1 [PSD, ES-08 Sander System No.1 [PSD,MACT Subpart DDDD] 58 Sander System No.l Exhaust
MACT Subpart DDDD] Filter
G-139 Recycled Fiber Silo No.I ES-09 Recycled Fiber Silo No.I [PSD,MACT Subpart DDDD] 59 Recycled Fiber Silo No. 1 Filter
[PSD,MACT Subpart
DDDD]
Group ID Group Description ES ID Emission Source Description OS ID OS Description
G-140 Sander System No.2[PSD ES-10 Sander System No.2[PSD,MACT Subpart DDDD] 60 Sander System No.2 Exhaust
MACT Subpart DDDD] Filter
G-142 Sander Dust Silo No. 1 ES-12 Sander Dust Silo No. 1 [PSD,MACT Subpart DDDD] 61 Sander Dust Silo No. 1 Filter
[PSD,MACT Subpart
DDDD]
G-143 Dry Sawdust Silo[PSD, ES-13 Dry Sawdust Silo[PSD,MACT Subpart DDDD] - 62 Dry Sawdust Silo Filter
MACT Subpart DDDD]
G-147 Log Processing Area I-LPA Log Processing Area 81 Never Commissioned
G-151 Recycled Fiber Silo No.2 ES-15 Recycled Fiber Silo No.2 [PSD,MACT Subpart DDDD] 63 Reject Fiber Silo No.2 Filter
[PSD,MACT Subpart
DDDD]
G-152 Sander Dust Silo No.2 ES-17 Sander Dust Silo No.2 [PSD,MACT Subpart DDDD] 64 Sander Dust Silo No.2 Filter
[PSD,MACT Subpart
DDDD]
G-153 Diesel Fuel-fired Fire Punr I-DFP-1 Diesel Fuel-fired Fire Pump Engine(347 Brake Horsepower 76 Diesel-fired fire pump engine
Engine(347 Brake output)[MACT ZZZZ,NSPS IIII] operation
Horsepower output)
[MACT ZZZZ,NSPS IIII]
G-154 Diesel Fuel-fired ES-21 Diesel Fuel-fired Emergency Generator(1592 Brake 80 MDF Emergency Generator
Emergency Generator Horsepower output)[PSD,MACT ZZZZ] Operation
(1592 Brake Horsepower
output)[PSD,MACT
ZZZZ]
G-155 Wastewater evaporator EVAP-1.19C Wastewater evaporator[MACT DDDD] 85 Wastewater evaporator
[MACT DDDD]
G-156 Backup natural gas-fired ES-02-C-1 Backup natural gas-fired dryer burner(35 million Btu per 86 MDF Backup Natural Gas Dryer Burners(ES-02C and
dryer burner(35 million hour heat input)[PSD,MACT Subpart DDDD] ES-02D)Combined 87 mmBTU/hr Firing Rate
Btu per hour heat input)
[PSD,MACT Subpart
DDDD]
G-157 ES-02-C-2 Backup natural gas-fired dryer burner(35 million Btu per 87 MDF Backup Natural Gas Dryer Burners(ES-02C and
hour heat input)[PSD,MACT Subpart DDDD] I ES-02D)Combined 87 mmBTU/hr Firing Rate
G-20 Sawdust Rock and Metal 3501 Sawdust Rock and Metal Separator[PSD,MACT Subpart 21 Rock and metal separator
Separator[BACT] DDDD] sawdust cleaning system
G-21 PZKR Green Chip Flakers 3585 PZKR Green Chip Makers[PSD,MACT Subpart DDDD] 29 Flaker exhaust system
[BACT]
G-25 Surface Material Transport 3515 Surface Material Transport(SL fines from screening 22 Fines transport systems
(SL fines from screening operation)[PSD,MACT Subpart DDDD]
operation)[PSD,MACT
Subpart DDDD]
G-26 Surface Formers and Mat 3525 Surface Formers and Mat Dumps[PSD,MACT Subpart 23 1 Wet(green)material transport
Dumps[BACT] JDDDDJ systems
Group ID Group Description ES ID Emission Source Description OS ID OS Description
G-27 Flying Cut Off Saw,Pretrii 3535 Flying Cut Off Saw,Pretrim Saws,&Production Collection 24 Dry material transport systems
Saws,&Production [PSD,MACT Subpart DDDD]
Collection[BACT]
G-28 Particleboard Press[PSD, DEF-2010 Particleboard Press[PSD,MACT Subpart DDDD] 4 Particleboard press
MACT Subpart DDDD]
G-32 Sander Filter Transport for 3575 Sander Filter Transport for Filters 3545&3565[PSD,MAC 28 Sanderdust silo transport system
Filters 3545&3565 Subpart DDDD]
[BACT]
G-33 Schelling Saw Board Trim 3555 Schelling Saw Board Trim[PSD,MACT Subpart DDDD] 27 Board trim and transfer system
[BACT]
G-34 Diesel-fired emergency I-ODG Diesel-fired emergency generator(465 horsepower,3026 7 Diesel-fired emergency
generator(465 million Btu per hour heat input)[MACT ZZZZ] generator
horsepower,3026 million
Btu per hour heat input)
[MACT ZZZZ]
G-35 Dry waste tranport system 3577 Dry waste tranport system[PSD,MACT Subpart DDDD] 35 Dry waste hammermill tranport
[BACT] system
G-47 One"Wellons"unit 3201 One"Wellons"unit operating as a: 36 Wellons Bypass for PB process
operating as a:a)wood a)wood suspension dust-fired burner(40 million Btu per
suspension dust-fired hour maximum rated heat input);or a
burner(40 million Btu per b)natural gas-fired burner(21.8 million Btu per hour
hour maximum rated heat maximum rated heat input); exhausting to either surface
input);or a b)natural layer triple pass,rotary drum(#3)dryer[ID No. 1430]andh
gas-fired burner(21.8 core layer single pass,rotary drum(#1)dryer[ID No. 1420]
million Btu per hour and/or core layer single pass,rotary drum(#2)dryer[ID
maximum rated No. 1410]
c)natural gas-fired indirect heat exchanger(21.8 million Bt
per hour maximum rated heat input)
[PSD,MACT Subpart DDDD]
G-48 Surface Hammermill and 3595 Oversize material Pallmann mill[MACT Subpart DDDD] 30 Dry material SL mill transport
Surface PZKR's
G-49 Particleboard Mill 3545.20A Particleboard Mill Steinemann Finishing Sander[PSD, 25 Steinmann sander for PB
Steinmann Finishing MACT Subpart DDDD] process
Sander[BACT]
G-50 Particleboard Mill 3565 Particleboard Mill Steinemann Calibrating Sander[PSD, 26 PB sanderdust transport for
Steinemann Calibrating MACT Subpart DDDD] sander
Sander[BACT]
G-51 particleboard dryers 1420 Core layer single pass,rotary drum(#1)dryer with one 3 particleboard dryers
wood suspension dust/natural gas-fired burner (50 million °
Btu per hour maximum rated heat input)[PSD,MACT
Subpart DDDD]
• t
Group ID Group Description ES ID Emission Source Description OS ID OS Description
G-51 particleboard dryers 1430 Surface layer triple pass,rotary drum(0)dryer with one 3 particleboard dryers
wood suspension dust/natural gas-fired burner(60 million
Btu per hour maximum rated heat input)[PSD,MACT
Subpart DDDD]
G-65 Particleboard Cooler PB-BC Particleboard Cooler[PSD][MACT Subpart DDDD] 39 Particle Board Cooler
[BACT]
G-69 Short Cycle Laminating 3593 Short Cycle Laminating Press 43 Wemhoner-Short cycle laminating press designed to
Press laminate MDF and/or Particleboard with overlay
G-71 Natural gas or No.2 fuel Pr-Heatl Natural gas or No.2 fuel oil-fired hot oil heater(4.7 million 46 Natural.gas or No.2 fuel oil-
oil-fired hot oil heater(4.7 Btu per hour heat input)used with short cycle laminating fired oil heater
million Btu per hour heat- presses[Case-by-Case MACT] (4.7MMBTU.hr)used with
input)used with short short cycle laminating presses
cycle laminating presses
[Case-by-Case MACT]
G-72 Short Cycle Laminating 3594 Short Cycle Laminating Press 48 Short Cycle Laminating press designed to laminate
Press MDF and/or Particleboard with overlay
GRI One 500 gallons above I-GAS One 500 gallons above ground gasoline storage tank 41 DOUBLE WALLED STORAGE
ground gasoline storage. ✓ TANK
tank
GR2 MDF Resin Tanks I-MDFR-1 MDF resin storage tank[MACT DDDD] 78 MDF Resin Tanks
I-MDFR-2 ✓ MDF resin storage tank,[MACT DDDD] MDF Resin Tanks
I-MDFR-3 ✓ MDF resin storage tank[MACT DDDD] MDF Resin Tanks
I-MDFR-4 MDF resin storage tank[MACT DDDD] MDF Resin Tanks
GR3 MDF Thermal Oil Heaters ES-18 Natural gas-fired hot oil heater(30.4 million Btu per hour 79 MDF Backup Natural Gas-fired
maximum heat input)[PSD,NSPS Dc,MACT DDDDD] Thermal Oil Burners
ES-19 Natural gas-fired hot oil heater(30.4 million Btu per hour MDF Backup Natural Gas-fired
maximum heat input)[PSD,NSPS De,MACT DDDDD] Thermal Oil Burners
ES-20 . Natural gas-fired hot oil heater(30.4 million Btu per hour MDF Backup Natural Gas-fired
maximum heat input)[PSD,NSPS Dc,MACT DDDDD] Thermal Oil Burners
GR4 Fugitives from wastewater I-Wastewater gon( Fugitives from wastewater lagoons 83 Fugitives from wastewater ponds
lagoons
GR5 Spray Irrigation Field I-Irrigation fu Spray Irrigation Field Fugitives 82 Fugitives from spray irrigation
Fugitives ✓ system
GR6 MDF Dryer Burners ES-02-D Backup natural gas-fired dryer burner(17 million Btu per 88 MDF Backup Natural Gas
(Natural Gas) hour heat input)[PSD,MACT Subpart DDDD] Dryer Burners(ES-02C and
ES-02D) Combined 87
mmBtu/hr Firing Rate
t
Facility Emissions - Operating Scenarios Per Pollutant
Arauco North America, Inc.
2019 Inventory
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) - 2018
Acetaldehyde
OS-3 6,452.00 Pounds 5,220.00 Pounds
1420 1420
1430 1430
OS-4 634.09 Pounds 521.35 Pounds
DEF-2010 DEF-2010
OS-7 0.010000 Pounds 0.020000 Pounds
I-ODG I-ODG
OS-39 180.43 Pounds 153.59 Pounds
PB-BC PB-BC
OS-69 5,099.00 Pounds 4,305.28 Pounds
ES-02-B ES-02-B
OS-75 2.17 Pounds 5.47 Pounds
ES-02-A ES-02-A
OS-76 0.060000 Pounds 0.080000 Pounds
I-DFP-1 I-DFP-1
OS-80 0.603930 Pounds 0.024400 Pounds
ES-21 ES-21
TOTAL in Current Inventory: 12,367.77 Pounds TOTAL in Previous Inventory: 10,205.81 Pounds
Acrolein
OS-3 1,978.00 Pounds 1,600.50 Pounds
1420 1420
1430 1430
OS-'4 140.23 Pounds 115.30 Pounds
DEF-2010 DEF-2010
7/1/2020 Page 1 of 29
r.
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
OS-7 0.000960 Pounds 0.001990 Pounds
I-ODG I-ODG
OS-39 49.97 Pounds 42.53 Pounds
PB-BC PB-BC
OS-69 110.56 Pounds 110.56 Pounds
ES-02-B ES-02-B
OS-75 0.562000 Pounds 1.42 Pounds
ES-02-A ES-02-A
OS-76 0.010000 Pounds 0.010000 Pounds
I-DFP-1 I-DFP-1
OS-80 0.00 123 0 Pounds 0.007640 Pounds
ES-21 ES-21
TOTAL in Current Inventory: 2,279.33 Pounds TOTAL in Previous Inventory: 1,870.33 Pounds
Arsenic Compounds-Arsine gas(Component of ASC)
OS-46 0.000100 Pounds 0.001100 Pounds
Pr-Heat 1 Pr-Heat 1
TOTAL in Current Inventory: 0.00 Pounds TOTAL in Previous Inventory: 0.00 Pounds
Arsenic Unlisted Compounds-Specify Compound(Component of E
OS-3 0.214000 Pounds 0.176200 Pounds
1420 1420
1430 1430
OS-36 0.002770 Pounds 0.023860 Pounds
3201 3201
OS-75 0.060000 Pounds 0.082000 Pounds
ES-02-A ES-02-A
OS-79 0.020500 Pounds 0.020000 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.000620 Pounds 0.003880 Pounds
ES-21 ES-21
7/1/2020 Page 2,of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS II) Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
TOTAL in Current Inventory: 0.30 Pounds TOTAL in Previous Inventory: '0.31 Pounds
Benzene
OS-3 157.00 Pounds 129.02 Pounds
1420 1420
1430 1430
OS-7 0.010000 Pounds 0.020000 Pounds
I-ODG I-ODG
OS-36 0.029040 Pounds 0.250510 Pounds
3201 3201
OS-41 0.350000 Pounds 0.350000 Pounds
I-GAS I-GAS
OS-46 0.001400 Pounds 0.011700.Pounds
Pr-Heat 1 Pr-Heat 1
OS-75 7.69 Pounds 10.53 Pounds
ES-02-A ES-02-A
OS-76 0.070000 Pounds 0.100000 Pounds
I-DFP-1 I-DFP-1
OS-79 0.215300 Pounds 0.214300 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.12 1000 Pounds 0.752000 Pounds
ES-21 ES-21 �
OS-88 0.240000 Pounds 0.240000 Pounds
ES-02-D ES-02-D
TOTAL in Current Inventory: 165.73 Pounds TOTAL in Previous Inventory: 141.49 Pounds
,Benzo(a)pyrene(Component of 83329/POMTV&56553/7PAH)
OS-3 1.00 Pounds 0.784900 Pounds
1420 1420
1430 1430
OS-75 0.085000 Pounds 0.116000 Pounds
ES-02-A ES-02-A
7/1/2020 Page 3 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
OS-80 0.000040 Pounds 0.000250 Pounds
ES-21 ES-21
TOTAL in Current Inventory: 1.09 Pounds TOTAL in Previous Inventory: 0.90 Pounds
Beryllium Metal(unreacted) (Component of BEC)
OS-80 0.000470 Pounds 0.002910 Pounds
ES-21 ES-21
TOTAL in Current Inventory: 0.00 Pounds TOTAL in Previous Inventory: 0.00 Pounds
Beryllium Unlisted Compounds-Specify Compound(Component a
OS-75 0.011000 Pounds 0.015000 Pounds
ES-02-A ES-02-A
OS-79 0.001200 Pounds 0.001200 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
TOTAL in Current Inventory: 0.01 Pounds TOTAL in Previous Inventory: 0.02 Pounds
Bromine
OS-3 16.00 Pounds 13.38 Pounds
1420 1420
1430 1430
TOTAL in Current Inventory: 16.00 Pounds TOTAL in Previous Inventory: 13.38 Pounds
Cadmium Metal,elemental,unreacted(Component of CDC)
OS-3 0.249000 Pounds 0.204700 Pounds
1420 1420
1430 1430
OS-36 0.015210 Pounds 0.131220 Pounds
3201 3201
OS-75 0.061000 Pounds 0.083000 Pounds
ES-02-A ES-02-A
OS-79 0.112800 Pounds 0.112200 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
7/1/2020 Page 4 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) - 2018
OS-80 0.000470,Pounds 0.002910 Pounds
ES-21 ES-21
TOTAL in Current Inventory: 0.44 Pounds TOTAL in Previous Inventory: 0.53 Pounds
Cadmium Unlisted Compounds-Specify Compound(Component o
OS-46 0.000700 Pounds 0.006100 Pounds
Pr-Heat] Pr-Heat]
TOTAL in Current Inventory: 0.00 Pounds TOTAL in Previous Inventory: 0.01 Pounds
Chlorine
OS-3 527.00 Pounds 433.64 Pounds
1420 1420
1430 1430
OS-75 25.85 Pounds 35.40 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 552.85 Pounds TOTAL in Previous Inventory: 469.04 Pounds
Chromic acid (VI)(Component of SolCIt6& CRC)
OS-80 0.000470 Pounds 0.002910 Pounds
ES-21 ES-21
TOTAL in Current Inventory: 0.00 Pounds TOTAL in Previous Inventory: 0.00 Pounds
Chromium (VI)&compounds
OS=3 0.182000 Pounds 0.149400 Pounds
1420 1420
1430 1430
OS-75 0.008000 Pounds 0.010520 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 0.19 Pounds TOTAL in Previous Inventory: 0.16 Pounds
Chromium Unlisted Compounds-Specify Compound(Component
OS-3 0.537000 Pounds 0.442000 Pounds
1420 1420
1430 1430
OS-36 0.001940 Pounds 0.016700 Pounds
3201 3201
7/1/2020 Page 5 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) - 2018
OS-46 0.000900 Pounds 0.007800 Pounds
Pr-Heat l Pr-Heat l
OS-75 0.166000 Pounds 0.226000 Pounds
ES-02-A ES-02-A
OS-79 0.143500 Pounds 0.142 800 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
TOTAL in Current Inventory: 0.85 Pounds TOTAL in Previous-Inventory: 0.84 Pounds
CO
OS-3 382.62 Tons 310.09 Tons
1420 1420
1430 1430
OS-4 0.120000 Tons 0.100000 Tons
DEF-2010 DEF-2010
OS-36 0.580000 Tons 5.01 Tons
3201 3201
OS-39 10.41 Tons 8.86 Tons
PB-BC PB-BC
OS-51 9.82 Tons
ES-02-A ES-02-A
OS-69 156.75 Tons 146.21 Tons
ES-02-B ES-02-B
OS-75 9.82 Tons 13.44 Tons
ES-02-A ES-02-A
OS-76 0.040000 Tons 0.050000 Tons
I-DFP-1 I-DFP-1
OS-79 4.31 Tons 4.29 Tons
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.070000 Tons 0.460000 Tons
7/1/2020 Page 6 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
ES-21 ES-21
OS-88 4.80 Tons 4.78 Tons
ES-02-D ES-02-D
TOTAL in Current Inventory: 579.34 Tons TOTAL in Previous Inventory: 493.29 Tons
Cobalt Unlisted Compounds-Specify Compound(Component of C
OS-3 0.313000 Pounds 0.258100 Pounds
1420 1420
1430 1430
OS-36 0.001160 Pounds 0.010020 Pounds
3201 3201
OS-46 0.000100 Pounds 0.000500 Pounds
Pr-Heat 1 Pr-Heat 1
OS-75 0.006000 Pounds 0.009000 Pounds
ES-02-A ES-02-A
OS-79 0.008600 Pounds 0.008600 Pounds
ES-18 ES-1.8
ES-19 ES-19
ES-20 ES-20
OS-88 0.010000 Pounds 0.010000 Pounds
ES=02-D ES-02-D
TOTAL in Current Inventory: 0.34 Pounds TOTAL in Previous Inventory: 0.30 Pounds
Cumene
OS-3 589.00 Pounds 501.39 Pounds
1420 1420
1430 1430
OS-4 7.61 Pounds 6.47 Pounds
DEF-2010 DEF-2010
OS-39 7.61 Pounds 6.47 Pounds
PB-BC PB-BC
OS-41 0.040000 Pounds _ 0.040000 Pounds
I-GAS I-GAS
OS-53 8.76 Pounds 7.15 Pounds
7/1/2020 Page 7 of 29
Facility Name:. Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
ES-03 ES-03
OS-54 8.76 Pounds 7.15 Pounds
ES-04 ES-04
OS-55 0.560000 Pounds 0.470000 Pounds
ES-05 ES-05
OS-69 996.28 Pounds 739.76 Pounds
ES-02-B ES-02-B
TOTAL in Current Inventory: 1,618.62 Pounds TOTAL in Previous Inventory: 1,268.90 Pounds
Ethylene dichloride(1,2-dichloroethane)
OS-75 0.949000 Pounds 1.30 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 0.95 Pounds TOTAL in Previous Inventory: 1.30 Pounds
Formaldehyde
OS-3 13,634.00 Pounds 11,032.00 Pounds
1420 1420
1430 1430
OS-4 9,694.23 Pounds 7,970.67 Pounds
DEF-2010 DEF-2010
OS-7 0.010000 Pounds 0.030000 Pounds
I-ODG I-ODG
OS-21 65.66 Pounds 55.90 Pounds
3501 3501
OS-22 113.89 Pounds 96.95 Pounds
3515 3515
OS-23 254.83 Pounds 216.93 Pounds
3525 3525
OS-24 319.28 Pounds 271.79 Pounds
3535 3535
OS-25 832.14 Pounds 708.38 Pounds
3545.20A 3545.20A
OS-26 273.67 Pounds 232.97 Pounds
7/1/2020 Page 8 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission hate -2019 Emission hate (Prev) -2018
3565 3565
OS-27 72.97 Pounds 62.12 Pounds
3555 3555
OS-28 372.63 Pounds 317.21 Pounds
3575 3575
OS-29 132.80 Pounds 113.05 Pounds
3585 3585
OS-30 13.39 Pounds 11.40 Pounds
3595 3595
OS-35 1,098.83 Pounds 935.40 Pounds
3577 3577
OS-36 1.04 Pounds 8.95 Pounds
3201 3201
OS-39 2,74738 Pounds 3,190.03 Pounds
PB-BC PB-BC
OS-43 62.42 Pounds
3593
OS-46 0.048200 Pounds 0.416100 Pounds .
Pr-Heat 1 Pr-Heat 1
OS-53 2,133.78 Pounds 1,741.41 Pounds
ES-03 ES-03
OS-54 2,133.78 Pounds 1,741.41 Pounds
ES-04 ES-04
OS-55 122.90 Pounds 104.75 Pounds
ES-05 ES-05
OS-57 102.07 Pounds 102.07 Pounds
ES-07 ES-07
OS-58 60.58 Pounds 60.58 Pounds
ES-08 ES-08
OS-59 112.19 Pounds 80.72 Pounds
ES-09 ES-09
7/1/2020 Page 9 of 29
Facility Name: Arauco North America, Inc.-
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) -2018
OS-60 60.58 Pounds 60.58 Pounds
ES-10 ES-10
OS-61 3.36 Pounds 2.74 Pounds
ES-12 ES-12
OS-63 112.19 Pounds 80.72 Pounds
ES-15 ES-15
OS-64 3.36 Pounds 2.74 Pounds
ES-17 ES-17
OS-69 10,462.16 Pounds 8,538.34 Pounds
ES-02-B ES-02-B
OS-75 28.89 Pounds 39.56 Pounds
ES-02-A ES-02-A
OS-76 0.090000 Pounds 0.130000 Pounds
I-DFP-1 I-DFP-1
OS-78 26.28 Pounds 26.28 Pounds
I-MDFR-1 I-MDFR-1
I-MDFR-2 I-MDFR-2
I-MDFR-3 I-MDFR-3
I-MDFR-4 I-MDFR-4
OS-79 7.69 Pounds 7.65 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.012300 Pounds 0.076500 Pounds
ES-21 ES-21
OS-82 3.83 Pounds 4.23 Pounds
I-Irrigation fugitiv I-Irrigation fugitiv
OS-83 4.81 Pounds 4.81 Pounds
I-Wastewater ponds I-Wastewater ponds
OS-88 8.58 Pounds 8.53 Pounds
ES-02-D ES-02-D
TOTAL in Current Inventory: 45,013.93 Pounds TOTAL in Previous Inventory: 37,893.93 Pounds
7/1/2020 Page 10 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) -2018
Hexachlorodibenzo-p-dioxin 1,2,3,6,7,8
OS-75 0.052000 Pounds 0.072000 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 0.05 Pounds TOTAL in Previous Inventory: 0.07 Pounds
Hexane,n-
OS-3 195.'00 Pounds 183.05 Pounds
1420 - 1420
1430 - 1430
OS-41 0.420000 Pounds 0.420000 Pounds
I-GAS I-GAS
OS-46 1.16 Pounds 9.99 Pounds
Pr-Heat l Pr-Heat l
OS-79 184.55 Pounds 183.64 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-88 205.84 Pounds 204.83 Pounds
ES-02-D ES-02-D
TOTAL in Current Inventory: 586.96 Pounds TOTAL in Previous Inventory: 581.93 Pounds
Hydrogen chloride(hydrochloric acid)
OS-3 1,048.00 Pounds 861.78 Pounds
1420 1420
1430 1430
OS-75 51.37 Pounds 70.34 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 1,099.37 Pounds TOTAL in Previous Inventory: 932.13 Pounds
Mang' nlisted Compounds-Specify Compound(Component
OS-3 23.00 Pounds 19.21 Pounds
1420 1420
1430 1430
OS-36 0.005250 Pounds 0.045330 Pounds
3201 3201
7/1/2020 Page 11 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
OS-46 0.000200 Pounds 0.002100 Pounds
Pr-Heat 1 Pr-Heat 1
OS-75 0.857000 Pounds 1.17 Pounds
ES-02-A ES-02-A
OS-79 0.039000 Pounds 0.038800 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.000940 Pounds 0.005820 Pounds
ES-21 ES-21
TOTAL in Current Inventory: 23.90 Pounds TOTAL in Previous Inventory: 20.48 Pounds
MEK(methyl ethyl ketone,2-butanone)
OS-3 1,668.00 Pounds 1,419.60 Pounds
1420 1420
1430 1430 1
OS-4 129.08 Pounds 109.88 Pounds
DEF-2010 DEF-2010
OS-39 15.27 Pounds 13.00 Pounds
PB-BC PB-BC
OS-75 0.096000 Pounds 0.241000 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 1,812.45 Pounds TOTAL in Previous Inventory: 1,542.72 Pounds
Mercury Unlisted Compounds-Specify Compound (Component of
OS-46 0.000200 Pounds 0.001400 Pounds
Pr-Heat 1 Pr-Heat 1
TOTAL in Current Inventory: 0.00 Pounds TOTAL in Previous Inventory: 0.00 Pounds
Mercury,vapor(Component of HGC)
OS-3 0.268000 Pounds 0.220660 Pounds
1420 1420
1430 1430
OS-36 0.003600 Pounds 0.031020 Pounds
7/1/2020 Page 12 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Numlber(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
3201 3201
OS-75 0.022000 Pounds 0.030000 Pounds
ES-02-A ES-02-A
OS-79 0.026700 Pounds 0.026500 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.000470 Pounds 0.002910 Pounds
ES-21 ES-21
TOTAL in Current Inventory: 0.32 Pounds TOTAL in Previous Inventory: 0.31 Pounds
Methanol(methyl alcohol)
OS-3 19,295.00 Pounds 15,611.00 Pounds
1420 1420
1430 1430
OS-4 25,607.40 Pounds 21,054.60 Pounds
DEF-2010 DEF-2010
OS-21 1,077.90 Pounds 917.50 Pounds
3501 3501
OS-22 1,611.44 Pounds 1,371.77 Pounds
3515 3515
OS-23 49.34 Pounds 42.00 Pounds
3525 3525
OS-24 131.57 Pounds 112.00 Pounds
3535 3535
OS-25 198.85 Pounds 169.28 Pounds
3545.20A 3545.20A
OS-26 59:80 Pounds 50.91 Pounds
3565 3565
OS-27 1 325.93 Pounds 277.46 Pounds
3555 3555
OS-28 80.74 Pounds 68.73 Pounds
3575 3575
7/l/2020 Page 13 of 29
Facility Name: Arauco North America,Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission hate (Prev) -2018
OS-29 882.12 Pounds 750.92 Pounds
3585 3585
OS-30 105.15 Pounds 89.51 Pounds
3595 3595
OS-35 799.15 Pounds 680.29 Pounds
3577 3577
OS-39 7,484.75 Pounds 6,380.05 Pounds
PB-BC PB-BC
OS-53 1,654.28 Pounds 1,350.08 Pounds
ES-03 ES-03
OS-54 1,654.28 Pounds 1,350.08 Pounds
ES-04 ES-04
OS-55 95.28 Pounds 81.21 Pounds
ES-05 ES-05
OS-57 1,417.62 Pounds 1,417.62 Pounds
ES-07 ES-07
OS-58 340.23 Pounds 340.23 Pounds
ES-08 ES-08
OS-59 86.98 Pounds 62.58 Pounds
ES-09 ES-09
OS-60 272.61 Pounds 272.61 Pounds
ES-10 ES-10
OS-61 15.10 Pounds 12.33 Pounds
ES-12 ES-12
OS-62 4.80 Pounds 3.91 Pounds
ES-13 ES-13
OS-63 86.98 Pounds 62.58 Pounds
ES-15 ES-15
OS-64 15.10 Pounds 12.33 Pounds
ES-17 ES-17
OS-69 506,732.64 Pounds 413,552.67 Pounds
7/1/2020 Page 14 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission bate-2019 Emission hate (Prev) -2018
ES-02-B ES-02-B
OS-75 8.67 Pounds 21.82 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 570,093.60 Pounds TOTAL in Previous Inventory: 466,116.06 Pounds
Methyl chloride(chloromethane)
OS-75 0.756000 Pounds 1.04 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 0.76 Pounds TOTAL in Previous Inventory: 1.04 Pounds
Methylene chloride
OS-3 234.00 Pounds 192.12 Pounds
1420 1420
1430 1430
OS-75 11.45 Pounds 15.68 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 245.45 Pounds TOTAL in Previous Inventory: 207.80 Pounds
MIBK(methyl isobutyl ketone)
OS-3 243.00 Pounds 207.02 Pounds
1420 1420
1430 1430
TOTAL in Current Inventory: 243.00 Pounds TOTAL in Previous Inventory: 207.02 Pounds
Naphthalene(Component of 83329/POMTV)
OS-3 27.00 Pounds 22.47 Pounds
1420 1420
1430 1430
OS-7 0.000880 Pounds 0.00 183 0 Pounds
I-ODG I-ODG
OS-36. 0.008430 Pounds 0.072770 Pounds
3201 3201
OS-41 0.090000 Pounds 0.090000 Pounds
I-GAS I-GAS
OS-46 0.000400 Pounds 0.003400 Pounds
7/1/2020 Page 15 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
Pr-Heat l Pr-Heat l
OS-75 2.43 Pounds 3.33 Pounds
ES-02-A ES-02-A
OS-76 0.010000 Pounds 0.010000 Pounds
I-DFP-1 I-DFP-1
OS-79 0.062500 Pounds 0.062200 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-88 0.070000 Pounds 0.070000 Pounds
ES-02-D ES-02-D
TOTAL in Current Inventory: 29.68 Pounds TOTAL in Previous Inventory: 26.11 Pounds
Nickel metal(Component of NIC)
OS-3 2.00 Pounds 1.89 Pounds
1420 1420
1430 1430
OS-36 0.029040 Pounds 0.250510 Pounds
3201 3201
OS-75 0.129000 Pounds 0.177000 Pounds
ES-02-A ES-02-A
OS-79 0.215300 Pounds 0.214300 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.000470 Pounds 0.002910 Pounds
ES-21 ES-21
TOTAL in Current Inventory:2.37 Pounds TOTAL in Previous Inventory: 2.54 Pounds
Nickel Unlisted Compounds(Component of NIC-Specify)
OS-46 0.001400 Pounds 0.011700 Pounds
Pr-Heat 1 Pr-Heat 1
TOTAL in Current Inventory: 0.00 Pounds TOTAL in Previous Inventory: 0.01 Pounds
7/l/2020 Page 16 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) -2018
NOx
OS-3 172.60 Tons 139.96 Tons
1420 1420
1430 1430
OS-4 1.21 Tons 1.00 Tons
DEF-2010 DEF-2010
OS-7 0.020000 Tons 0.050000 Tons
I-ODG I-ODG
OS-36 0.690000 Tons 5.96 Tons
3201. 3201
OS-51 5.40 Tons
ES-02-A ES-02-A
OS-69 86.21 Tons 80.42 Tons
ES-02-B ES-02-B
OS-75 5.40 Tons 7.39 Tons
ES-02-A ES-02-A
OS-76 0.170000 Tons 0.240000 Tons
I-DFP-1 I-DFP-1
OS-79 5.13 Tons 5.10 Tons
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.350000 Tons 2.15 Tons
ES-21 ES-21
OS-88 2.86 Tons 2.84 Tons
ES-02-D ES-02-D
TOTAL,in Current Inventory: 280.04 Tons TOTAL,in Previous Inventory: 245.11 Tons
Phenol
OS-3 1,449.00 Pounds 1,172.00 Pounds
1420 1420
1430 1430
OS-4 1,006.01 Pounds 827.15 Pounds
7/l/2020 Page 17 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) -2018
DEF-2010 DEF-2010
OS-39 652.32 Pounds 555.30 Pounds
PB-BC PB-BC
OS-62 21.58 Pounds 17.61 Pounds
ES-13 ES-13
OS-69 16,136.27 Pounds 15,485.68 Pounds
ES-02-B ES-02-B
OS-75 0.352000 Pounds 0.887000 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 19,265.53 Pounds TOTAL in Previous Inventory: 18,058.63 Pounds
Phosphorus Metal,Yellow or White
OS-75 3.22 Pounds 4.41 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 3.22 Pounds TOTAL in Previous Inventory: 4.41 Pounds
PM(T )
OS-3 27.06 Tons 5 21.94 Tons
1420 ,' 1420
1430 1430
OS-4 10.33 Tons 8.50 Tons
DEF-2010 DEF-2010
OS-21 0.040000 Tons 0.040000 Tons
3501 3501
OS-22 0.020000 Tons 0.010000 Tons
3515 3515
OS-23 0.020000 Tons 0.010000 Tons
3525 3525
OS-24 0.020000 Tons 0.010000 Tons
3535 3535
OS-25 0.020000 Tons 0.020000 Tons
3545.20A 3545.20A
OS-26 1.97 Tons 1.68 Tons
7/1/2020 Page 18 of 29
. Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit lelumber(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) -2018
3565 3565
OS-27 0.010000 Tons 0.010000 Tons
3555 3555
OS-28 1.77 Tons 1.51 Tons
3575 3575
OS-29 9.69 Tons 8.25 Tons
3585 3585
OS 30 0.010000 Tons 0.010000 Tons
3595 3595
OS-35 0.050000 Tons 0.040000 Tons
3577 3577
OS-36 0.050000 Tons 0.450000 Tons
3201 3201
OS-39 15.75 Tons 13.41 Tons
PB-BC PB-BC
OS-43 1.34 Tons
3593
OS-51 8.18 Tons
ES-02-A ES-02-A
OS-53 2.04 Tons 2.03 Tons
ES-03 ES-03
OS-54 1.93 Tons 1.93 Tons
ES-04 ES-04
OS-55 0.090000 Tons 0.080000 Tons
ES-05 ES-05
OS-57 2.95 Tons 2.94 Tons
ES-07 ES-07
OS-58 3.16 Tons 3.15 Tons
ES-08 ES-08
OS-60 1.58 Tons 1.58 Tons
ES-10 ES-10
7/1/2020 Page 19 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) - 2018
OS-61 0.040000 Tons 0.040000 Tons
ES-12 ES-12
OS-62 - 0.070000 Tons 0.070000 Tons
ES-13 ES-13
OS-64 0.040000 Tons 0.040000 Tons
ES-17 ES-17
OS-69 61.14 Tons 49.89 Tons
ES-02-B ES-02-B
OS-74 0.260000 Tons 0.260000 Tons
ES-01 ES-01
OS-75 8.18 Tons 11.20 Tons
ES-02-A ES-02-A
OS-76 0.010000 Tons 0.020000 Tons
I-DFP-1 I-DFP-1
OS-79 0.390000 Tons 0.390000 Tons
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.020000 Tons 0.150000 Tons
ES-21 ES-21
OS-88 0.030000 Tons 0.030000 Tons
ES-02-D ES-02-D
TOTAL in Current Inventory: 156.92 Tons TOTAL in Previous Inventory: 131.03 Tons
PM10
OS-3 27.06 Tons 21.94 Tons
1420 1420
1430 1430
OS-4 1033 Tons 8.50 Tons
DEF-2010 DEF-2010
OS-21 0.040000 Tons 0.040000 Tons
3501 3501
OS-22 0.020000 Tons 0.010000 Tons
7/1/2020 Page 20 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53' .
Pollutant
OS ID Emission
Source'ID Emission Rate-2019 Emission Rate (Prev) -2018
3515 3515
OS-23 0.020000 Tons 0.010000 Tons
3525 3525
OS-24 0.020000 Tons 0.010000 Tons
3535 3535
OS-25 0.020000 Tons 0.020000 Tons
3545.20A 3545.20A
OS-26 1.97 Tons 1.68 Tons
3565 3565
OS-27 0.010000 Tons 0.010000 Tons
3555 3555
OS-28 1.77 Tons 1.51 Tons
3575 3575
OS-29 9.69 Tons 8.25 Tons
3585 3585
OS-30 0.010000 Tons 0.010000 Tons
3595 3595
OS-35 0.050000 Tons 0.040000 Tons
3577 3577
OS-36 0.050000 Tons 0.450000 Tons
3201 3201
OS-39 15.75 Tons 13.41 Tons
PB-BC PB-BC
OS-43 0.860000 Tons
3593
OS-51 8.18 Tons
ES-02-A ES-02-A
OS-53 2.04 Tons 2.03 Tons
ES-03 ES-03
OS-54 1.93 Tons 1.93 Tons
ES-04 ES-04
7/1/2020 Page 21 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03440T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) -2018
OS-55 0.090000 Tons 0.080000 Tons
ES-05 ES-05
OS-57 2.95 Tons 2.94 Tons
ES-07 ES-07
OS-58 3.16 Tons 3.15 Tons
ES-08 ES-08
OS-60 1.58 Tons 1.58 Tons
ES-10 ES-10
OS-61 0.040000 Tons 0.040000 Tons
ES-12 ES-12
OS-62 0.070000 Tons 0.070000 Tons
ES-13 ES-13
OS-64 0.040000 Tons 0.040000 Tons
ES-17 ES-17
OS-69 61.14 Tons 49.89 Tons
ES-02-B ES-02-B
OS-74 0.260000 Tons 0.260000 Tons
ES-01 ES-01
OS-75 8.18 Tons 11.20 Tons
ES-02-A ES-02-A
OS-76 0.010000 Tons 0.020000 Tons
I-DFP-1 I-DFP-1
OS-79 0.390000 Tons 0.390000 Tons
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.020000 Tons 0.150000 Tons
ES-21 ES-21
OS-88 0.030000 Tons 0.020000 Tons
ES-02-D ES-02-D
TOTAL in Current Inventory: 156.92 Tons TOTAL in Previous Inventory: 130.54 Tons
7/1/2020 Page 22 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
PM2.5
OS-3 27.06 Tons 21.94 Tons
1420 1420
1430 1430
OS-4 3.57 Tons 2.93 Tons
DEF-2010 DEF-2010
OS-21 0.040000 Tons 0.040000 Tons
3501 3501
OS-22 0.020000 Tons 0.010000 Tons
3515 3515
OS-23 0.020000 Tons 0.010000 Tons
3525 3525
OS-24 0.020000 Tons 0.010000 Tons
3535 3535
OS-25 0.020000 Tons 0.020000 Tons
3545.20A 3545.20A
OS-26 1.97 Tons 1.68 Tons
3565 3565
OS-27 0.010000 Tons 0.010000 Tons
3555 3555
OS-28 1.77 Tons 1.51 Tons
3575 3575
OS-29 9.69 Tons 8.25 Tons
3585 3585
OS-30 0.010000 Tons 0.010000 Tons
3595 3595
OS-35 0.050000 Tons 0.040000 Tons
3577 3577
OS-36 0.050000 Tons 0.450000 Tons
3201 3201
OS-39 5.34 Tons 4.55 Tons
PB-BC PB-BC
7/1/2020 Page 23 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) -2018
OS-43 0.480000 Tons
3593
OS-51 7.03 Tons
ES-02-A ES-02-A
OS-53 2.04 Tons 2.03 Tons
ES-03 ES-03
OS-54 1.93 Tons 1.93 Tons
ES-04 ES-04
OS-55 0.090000 Tons 0.080000 Tons
ES-05 ES-05
OS-57 2.95 Tons 2.94 Tons
ES-07 ES-07
OS-58 3.16 Tons 3.15 Tons
ES-08 ES-08
OS-60 1.58 Tons 1.58 Tons
ES-10 ES-10
OS-61 0.040000 Tons 0.040000 Tons
ES-12 ES-12
OS-62 0.070000 Tons 0.070000 Tons
ES-13 ES-13
OS-64 0.040000 Tons 0.040000 Tons
ES-17 ES-17
OS-69 61.14 Tons 49.89 Tons
ES-02-B ES-02-B
OS-74 0.260000 Tons 0.260000 Tons
ES-01 ES-01
OS-75 7.03 Tons 9.63 Tons
ES-02-A ES-02-A
OS-76 0.010000 Tons 0.020000 Tons
I-DFP-1 I-DFP-1
OS-79 0.390000 Tons 0.390000 Tons
7/1/2020 Page 24 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) -2018
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.020000 Tons 0.150000 Tons
ES-21 ES-21
OS-88 0.020000 Tons 0.020000 Tons
ES-02-D ES-02-D
TOTAL in Current Inventory: 137.44 Tons TOTAL in Previous Inventory: 114.16 Tons
Polycyclic Organic Matter(Inc PAH,dioxins,etc.NC&AP 42 histc
0S-3 116.00 Pounds 95.37 Pounds
1420 1420
1430 1430
OS-7 0.000870 Pounds 0.001790 Pounds
I-ODG I-ODG
OS-46 0.000400 Pounds 0.003500 Pounds
Pr-Heat 1 Pr-Heat 1
OS-75 4.09 Pounds 5.60 Pounds
ES-02-A ES-02-A
OS-76 0.010000 Pounds 0.010000 Pounds
I-DFP-1 I-DFP-1
OS-79 0.064400 Pounds 0.064100 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
TOTAL in Current Inventory: 120.17 Pounds TOTAL in Previous Inventory: 101.05 Pounds
Propionaldehyde
OS-3 566.00 Pounds 457.99 Pounds
1420 1420
1430 1430
OS-4 103.65 Pounds 85.22 Pounds
DEF-2010 DEF-2010
OS-69 81.78 Pounds 81.78 Pounds
ES-02-B ES-02-B
7/1/2020 Page 25 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate-2019 Emission Rate (Prev) -2018
OS-75 0.57 1000 Pounds 1.44 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 752.00 Pounds TOTAL in Previous Inventory: 626.43 Pounds
S02
OS-3 0.080000 Tons 6.87 Tons
1420 1420
1430 1430'
OS-51 6.53 Tons
ES-02-A ES-02-A
OS-69 6.53 Tons 6.09 Tons
ES-02-B ES-02-B
OS-75 0.410000 Tons 0.560000 Tons
ES-02-A ES-02-A
OS-76 0.010000 Tons 0.020000 Tons
I-DFP-1 I-DFP-1
OS-80 0.020000 Tons 0.140000 Tons
ES-21 ES-2.1
OS-88 0.030000 Tons 0.030000 Tons
ES-02-D ES-02-D
TOTAL in Current Inventory: 13.61 Tons TOTAL in Previous Inventory: 13.71 Tons
Toluene
OS-3 16.00 Pounds 12.89 Pounds
1420 1420
1430 1430
OS-36 0.047010 Pounds 0.410000 Pounds
3201 3201
OS-41 169.64 Pounds 169.64 Pounds
I-GAS I-GAS
OS-46 0.002200 Pounds 0.018900 Pounds
Pr-Heat l Pr-Heat l
OS-75 0.766000 Pounds 1.05 Pounds
7/1/2020 Page 26 of 29
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission hate -2019 Emission hate (Prev) -2018
ES-02-A ES-02-A
OS-76 0.030000 Pounds 0.040000 Pounds
I-DFP-1 I-DFP-1
OS-79 0.348600 Pounds 0.346900 Pounds
ES-18 ES-18
ES-19 ES-19
ES-20 ES-20
OS-80 0.043800 Pounds 0.272000 Pounds
ES-21 ES-21
OS-88 0.390000 Pounds 0.390000 Pounds
ES-02-D ES-02-D
TOTAL in Current Inventory: 187.27 Pounds TOTAL in Previous Inventory: 185.06 Pounds
Vinyl chloride
OS-75 0.602000 Pounds 0.824000 Pounds
ES-02-A ES-02-A
TOTAL in Current Inventory: 0.60 Pounds TOTAL in Previous Inventory: 0.82 Pounds
VOC
OS-3 163.45 Tons 132.25 Tons
1420 1420
1430 1430
OS-4 1.88 Tons 4.00 Tons
DEF-2010 DEF-2010
OS-21 15.12 Tons 12.87 Tons
3501 3501
OS-22 59.30 Tons �nJ
3515 I 3515
OS-23 0.830000 Tons 0.710000 Tons
3525 3525
OS-24 6.41 Tons 5.45 Tons
3535 3535
OS-25 2.98 Tons 2.53 Tons
3545.20A 3545.20A
7/1/2020 Page 27 of 29
Facility Name: Arauco North America, Inc. -
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev)-2018
OS-26 1.16 Tons 0.990000 Tons
3565 3565
OS-27 2.51 Tons 2.13 Tons
3555 3555
OS-28 1.57 Tons 1.33 Tons
3575 3575
OS-29 8.51 Tons 7.25 Tons
3585 3585
OS-30 0.590000 Tons 0.500000 Tons
3595 3595
OS-35 27.06 Tons 23.04 Tons
3577 3577
OS-36 0.040000 Tons 0.330000 Tons
3201 3201
OS-39 9.29 Tons 7.91 Tons
PB-BC PB-BC
OS-43 0.060000 Tons
3593
OS-46 0.030000 Tons 0.230000 Tons
Pr-Heat 1 Pr-Heat 1
OS-51 933.80 Tons
ES-02-A ES-02-A
OS-53 10.54 Tons 8.60 Tons
ES-03 ES-03
,OS-54 10.54 Tons 8.60 Tons
ES-04 ES-04
OS-55 0.610000 Tons 0.520000 Tons
ES-05 ES-05
OS-57 0.850000 Tons 0.850000 Tons
ES-07 ES-07
OS-58 0.840000 Tons 0.840000 Tons
7/1/2020 Page 28 of 29
•
Facility Name: Arauco North America, Inc.
Facility ID: 1900015 Permit Number(s): 03449T53
Pollutant
OS ID Emission
Source ID Emission Rate -2019 Emission Rate (Prev) -2018
ES-08 ES-08
OS-59 0.550000 Tons 0.400000 Tons
ES-09 ES-09
OS-60 0.840000 Tons 0.840000 Tons
ES-10 ES-10
OS-61 0.050000'Tons 0.040000 Tons
ES-12 ES-12
OS-62 0.060000 Tons 0.050000 Tons
ES-13 ES-13
OS-63 0.550000 Tons 0.400000 Tons
ES-15 ES-15
OS-64 0.050000 Tons 0.040000 Tons
ES-17 ES-17
OS-6 9933.80 Tons U 762.09 Tons
ES-02-B ES-02-B
OS-75 0.280000 Tons 0.380000 Tons
ES-027A ES-02-A
OS-76 0.010000 Tons 0.020000 Tons
I-DFP-1 I-DFP-1
OS-78 0.020000 Tons 0.020000 Tons
I-MDFR-1 I-MDFR-1
I-MDFR-2 I-MDFR-2
I-MDFR-3 I-MDFR-3
I-MDFR-4 I-MDFR-4
OS-80 0.030000 Tons 0.170000 Tons
ES-21 ES-21
OS-88 0.310000 Tons 0.310000 Tons
ES-02-D ES-02-D
TOTAL in Current Inventory: 2,194.46 Tons TOTAL in Previous Inventory: 985.75 Tons
7/1/2020 Page 29 of 29
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment/Process: Two Stage Dryer System(softwood Bring) -
Equipment ID Number: ES-02B
Emission Point: CD-18
Control Device. CD-021CD-14&CD-18
2019 Actual Process Throughput:
100%Sofwood Production= 239,750 ODMT/yr
MDF Production= 151,449 MSF 3/4"/yr
Furnace Wood Combustion Throughput 522,509 MMBiu/yr _
Hours ofOperatimn= 7,503 hr/yr
Bioflter Uptinic= 0 person
Ratio ofMDFTO HDF= 100%MDF
VOC Control Efficintcy= 0.0%
Methanol Control ElRcivm,y= 0.0%
Formaldehyde Control ElTciendy- 0.01/.
2019 Actual Emissions Summary:
Control
Efficiency
Compound Emission Factor RMerence Uncontrolled Emissions Controlled Emissions
PM 0.51 Ib/ODMT 1 122,272.5 Ib/rl__61.14 my 122,272.5 lb/yr 61.14 ipy
PM,..", 0.51 Ib/ODMT 1 122,272.5 Iblyr 61.14 1py 122,272.5 Ib/yr 61.14 Ipy
NO 11.33 Ib/MMBnt 1 172,428.0 Ib/r 86.21 1py 172,428.0 lblyr 86.21 ipy _
CO 0.60 Ib/MMBtu 2 313 505.5 lb/yr 156.75 ipy 313 505.5 Wye 156.75 Ipy VOC avg 135.45
SO, 2.50E-02 Ib/MMBtu 2 13,062.7 Iblyr 6.53 tpy 13,062.7 1b/ 6.53 ipy
VOC 7.79 Ib/ODMT 3 1867 602.4 Ib/vr 933.80 1py 1867 602.4 Ih/vr 933.90 Ipy
Lead 4.80E-05 Ib/MMBtu 1 25.08 Ib/r 1.25E-02 Ipy 25.08 lb/yr 0.01 I
CO'. 4 I09,494,574.2 Ib/yr 54,747.3 1py 109.494,574.2 lb/yr 54,747.3 tpy hum 13,20181.1 data(production rate mteastms BDMTdv),Appendix S.
CO, 206.793 Ib/MMBm 5 108,051,431.0 Ib/yr 54,025.7 1py 108,051,431.0 lb/yr 54,025.7 1py average 26.3533 ODMT/Irr
CH, 0.016 Ib/MMBIu 5 8,293.9 Hily, 4.15 1py 9,293.9 Iblyr 4.15 ipy
N_,O 0.008 1b/MMBbt 5 4,147.0 Ih/yr 2.07 ipy 4,147.0 lbtyr 2.07 tpy hdd Outlet
- - - - -total lh/yr HCHO 35.7 1.15 96.8%
Acetaldeh do cr 1.93E-02 lb/ODT 6 5,099.10 lb/yr 2.5 ipy 5,099.10 lb/yr 2.55 ipy 6,295.55 McOH 69.3 55.7'19.6%
AcGaldehvde(press) 7.90E-03 1b/MSF 7 1,196.45 lblyr 0.6 Ipy 1196.45 Ib/yr 0.60 ipy Total 105 56.85 45.9%
Acomem 7.311E-04 Ib/MSF 7 110.56 Iblyr 0.1 1pv 110.56 Ility, 0.06 tpy
Cumene d 3.74E-03 Ib/ODT 8 987.98 lb/r 0.5 IPY 987.98 lblyr 0.49 tpy 996.27
Cumene ucss 5.48E-05 Ib/MSF 7 8.30 lb/yr 4.15E-03 Ipy 8.30 lb/w 4.15E-03 1py
Funnaldch de 4.36E-02 Ib/ODMT 3 10462.16 Ib/yr 5.21 v 10462.16 Ih1vr triv
Methanol 2.11E+00 lb/ODMT 3 506732.64 lb/vr 253.4 Ipy 506,7.32.64 Ib/yr try
Na hthalerm 6.60E-04 Ib/ODT 7 174.42 Ib/r 0.1 tpy 174.42 Ili/ 0.09 TpY
Phenol d ern 9.48E-03 Ib/ODT 6 2.505.84 Ib/ 1.3 1 2,505.84 Ibt 1.25 t 16,136.27
Phenol cress 9.00E-02 Ib/MSF 9 13.630.43 Ib/vr 6.8 I 13 630.43 Ib/ G.82 I
Pro ionaldJr do d" 1.10E-03 Ib/ODT 7 290.71 Ib/ 11.1 1 v 29U.71 Ib/ U.IS t
Pm ioualdehvde(press) 5.411E-041b/MSF 7 81.78 lb/yr 4.09E-021 v 81.78 lb/yr 0.04 ipy _
References:
i.Emission factors from Air Permit 03449T45,Table 2.2.B.1.
2.Emission factors based on AP42,Chapter 1,Section 6,Table 1.6-2(S picmber 2003 Revision).Lead is f sin Table 1.6-4.
3.Source Testing Conducted at the Moncure mill.VOC IL st d;na form May 31,20181aiing.Fornmldehyde rand mdhanol dma Imo June I3,20IS Iesling.
- 4.Global warning Potentials or.obtainttl from 40 CFR 98,Subpart A,Table A-I:
CO,: I
CIL: 25
N,O: • 298
5.Emission factors based on 40 CFR 98,Subpart C,Tables C-I and C-2 for Wood and Wood Residuals.
6.Emission factors per NCASI TB770,Table 6.1.2 Mill 132 average.January 1999.
7.NCASI SARA 313 Guidance for Wood Pmducls Facilities,updated Mama 2011. _
8.NCASI emission factor database cuniene ouissions from ftberlwanl refiner wet wood(50%moisture).
9.NCASI Technical Bulletin 770,Volatile Organic Compotmd Emissions front Wood Products Manufacturing Facilities,Part III-Malium Density Fiberboanl(01/1999),
Mill 142 Press Emissions,Table 5.1.5,Board Press Emissions,Mill 100.
tort twF�sme
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment/Process: Two Stage Dryer System(natural gas firing)
Equipment ID Number: ES-02C-1,ES-02C-2,ES-02D
Emission Point: CD-18
Control Device: CD-02/CD-14&CD-18 -
2019 Actual Process Throughput:
Backup Natural Gas-fired Dryer Burners= 114 MMscf/yr
VOC Control Efficiency= 0%
PM/Metals Control Efficiency= 0%
2019 Actual Emissions Summary:
Control
Efficiency
Compound Emission Factor (%) Reference Uncontrolled Emissions Controlled Emissions.
NO, 50 lb/MMscf - 1 5,718 Ib/yr 2.86 tpy 5,717.75 Ib/yr 2.86 tpy
CO 84 lb/MMscf - 1 9,606 lb/ r 4.80 tpy 9,605.83 lb/ r 4.80 tpy
PM 0.52 lb/MMscf - 1 59 lb/ r 0.03 tpy 59.46 lb/ r 0.03 tpy
PMio/2.5 0.43 lb/MMscf - 1 49 lb/yr 0.02 tpy 49.17 lb/yr 0.02 tpy
SOS 0.60 lb/MMscf. - 1 69 lb/yr 0.03 tpy 68.61 lb/yr 0.03 tpy
VOC 5.5 lb/MMscf - 1 629 lb/ r 0.31 tpy 628.95 lb/ r 0.31 tpy
Benzene 2.10E-03 lb/MMscf - 1 0.24 lb/ r 1.20E-04 tpy 0.24 lb/ r 1.20E-04 tpy
Benzo(a)pyrene 1.20E-06 lb/MMscf - 1 0.00 lb/ r 6.86E-08 tpy 0.00 Ib/ r 6.86E-08 tpy .
Cobalt compounds 8.40E-05 lb/MMscf - 1 0.01 lb/ r 4.80E-06 tpy 0.01 lb/ r 4.80E-06 tpy
Formaldehyde 7.50E-02 lb/MMscf - 1 8.58 lb/ r 0.00 tpy 8.58 lb/ r 4.29E-03 tpy
Hexane 1.80E+00 lb/MMscf - 1 205.84 lb/ r 0.10 tpy 205.84 lb/ r 0.10 tpy
Naphthalene 6.10E-04 lb/MMscf - 1 0.07 lb/ r 3.49E-05 tpy 0.07 lb/ r 3.49E-05 tpy
Selenium compounds 2.40E-05 1b1MMscf - 1 0.00 lb/ r 1.37E-06 tpy 0.00 lb/ r 1.37E-06 tpy
Toluene I 3.40E-03 lb/MMscf 1 1 0.39 lb/ r 0.00 tpy 0.39 lb/ r 1.94E-04 tpy
References:
1. Emission factors based on AP-42�Fifth Edition,Chapter 1,Section 4,July 1998.Taken from DAQ Natural Gas Combustion Emission Calculator Revision
01/05/2017 spreadsheet online. PMIO is assumed to be eqeual to PM1.5.
1 of 1 MDF-ES-02C&D
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Fiber Sifter System Filter
Equipment ID Number: ES-03
Emission Point: EP-03
Control Device: CD-03
2019 Actual Process Throughput:
Operation= 7,022 hr/yr
Annual Refiner Production= 239,750 ODMT/yr
2019 Actual Emissions Summary:
Control
Efficiency Uncontrolled and Controlled
Compound Emission Factor (%) Reference Emissions
PM 0.58 lb/hr - 1 4,072.73 lb/ r 2.04 tpy
PMI0i2.5 0.58 lb/hr - 1 4,072.73 lb/yr 2.04 tpy
Total VOC/WPP1 VOC 8.79E-02 lb/ODMTj 2 21,083.05 lb/yr 10.54 tpy
Cumene 3.65E-05 lb/ODMT - 3 8.76 lb/yr 4.38E-03 tpy
Formaldehyde 8.90E-03 lb/ODMT - 2 2,133.78 lb/yr 1.07 tpy
Methanol 6.90E-03 lb/ODMT - 2 1,654.28 lb/yr .0.83 tpy
References:
1. Emission factors from source testing in 2003. All PM is assumed to be PM,.5.
2. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,
Part III—Medium Density Fiberboard(01/1999),Table 5.2.3,Former Mat Vacuum System Emissions,Mill 132.
VOC: Converted from VOC as C to VOC as propane+methanol+formaldehyde.
3. Cumene emissions from PB dryers drying raw, dry wood(<20%moisture)NCASI database.
1 of 1 MDF-ES-03
PB and MDF,Moncure;NC
Permit Number 03449T51
Emission Unit Equipment: Forming Line Clean-Up Filter
Equipment ID Number: ES-04
Emission Point: EP-04
Control Device: CD-01
2019 Actual Process Throughput:
Operation= 7,022 hr/yr
Annual Refiner Production= 239,750 ODMT/yr
2019 Actual Emissions Summary:
Control
Efficiency Uncontrolled and Controlled
Compound Emission Factor (%) Reference Emissions
PM 0.55 lb/hr - 1 3,862.07 lb/ r 1.93 t y
PM10i2.5 0.55 lb/hr - 1 1 3,862.07 lb/yr 1.93 tpy
VOC -25A as carbon 8.79E-02 lb/ODMTI 2 21,083.05 lb/yr 10.54 t
Cumene 3.65E-05 lb/ODMT - 3 8.76 lb/ r I 4.38E-03 tpy
Formaldehyde 8.90E-03 lb/ODMT - 2 2,133.78 lb/yr I 1.07E+00 tpy
Methanol 6.90E-03 lb/ODMT - 1 2 1,654.28 lb/ r I 8.27E-01 t
References:
1. Emission factors from source testing in 2003. All PM is assumed to be PM2.5•
2. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,
Part III—Medium Density Fiberboard(0l/1999),Table 5.2.3,Former Mat Vacuum System Emissions,Mill 132.
VOC: Converted from VOC as C to VOC as propane+methanol +formaldehyde.
3. Cumene emissions from PB dryers drying raw,dry wood(<20%moisture)NCASI database.
1 of 1 MDF-ES-04
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Mat Reject Sysetm Filter
Equipment ID Number: ES-05
Emission Point: EP-05
Control Device: CD-05
2019 Actual Process Throughput:
Operation= 395 hr/yr
Mat Reject Production I= 13,809 ODMT/yr
2019 Actual Emissions Summary:
Control
Efficiency
Compound Emission Factor M Reference Uncontrolled and Controlled Emission
PM 0.48 lb/hr 2 189.36 lb/ r 9.47E-02 tpy C3H8 44 amu
PM10/2.5 0.48 lb/hr 2 189.36 1b/yr 9.47E-02 tpy Carbon in Propan 36 amu
VOC-WPP1 8.79E-02lb/ODMT 3 1,214.32 ib/ r 6.07E-01 tpy 1 ton 0.907 tonne
Cumene 4.0313-05 lb/ODMTI 4 1 0.56 lb/ r 2.78E-04 tpy
Fonnaldeh de I 8.90E-03 lb/ODMTI 3 1 122.90 lb/ r 6.14E-02 tpy
Methanol 6.90E-03 lb/ODMTJ 3 95.28 Ib/ r 4.76E-02 tpy
References:
1.Value is a function of mat reject time. Calculated by the following equation:
[Annual Press Production Hrs/6,145]*Mat Reject Operation Hours
2.Emission factors from source testing in 2003.All PM is assumed to be PIy15. —
3.NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part
III—Medium Density Fiberboard(01/1999),Table 5.2.3,Former Mat Vacuum System Emissions,Mill 132.
VOC:Converted from VOC as C to VOC as propane+methanol+formaldehvde.
4.Cumene emissions from PB dryers drying raw,dry wood(<20%moisture)NCASI database.
• k*
1 of 1 MDF-ES-05
_ l
PB and NIDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment/Process: Board Cooler
Equipment ID Number: ES-06B
Emission Point:
Control Device: CD-02, CD-14
2019 Actual Process Throughput:
Annual Press Production= 151,449 MSF 3/4"/yr
2019 Actual Emissions Summary:
Emissions are included in the dryer calculations. See tab MDF-ES-02C&D.
1 of 1 MDF-ES-06B
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Saw System Filter(Diagonal Saw,Trim Saw,Finishing Saws)
Equipment ID Number: ES-07
Emission Point: EP-07
Control Device: CD-07
2019 Actual Process Throughput:
Operation= 7,022 hr/yr
.gal Trim Reclaim(3% of Press Production)= 4,543 MSF 3/4"/yr
Annual Trim Reclaim= 5,670 ODMT/yr
2019 Actual Emissions Summary:
on ro
Efficiency Uncontrolled and Controlled
Compound Emission Factor M Reference Emissions
PM 0.84 lb/hr - 1 5,898.43 lb/yr 2.95 tpy
PM10i2.5 0.84 lb/hr - 1 5,898.43 lb/yr 2.95 tpy
VOC-WPP1 3.74E-01 lb/MSF - 2 1,700.23 lb/ r 0.85121
Formaldehyde 1.80E-02 lb/O MT - 2 102.07 lb/yr 0.05 tpy
Methanol I 2.50E-01 lb/ODMTI 2 1 1,417.62 lb/yr 0.71 tpy
References:
1. Emission factors from source testing in 2003.All PM is assumed to be PM,.5.
2. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing
Facilities,Part III—Medium Density Fiberboard(01/1999),Table 5.2.4,Miscellaneous Source Emissions,Mill 132
(Saw Reclaim Sysetm Baghouse Exhaust).
VOC: Converted from VOC as C to VOC as propane+methanol+formaldehyde.
1 of 1 MDF-ES-07
PB and MDF,Moncure,NC
Permit Dumber 03449T51
Emission Unit Equipment: Sander System No. 1 Exhaust Filter
Equipment ID Number: ES-08
Emission Point: EP-08
Control Device: CD-08
2019 Actual Process Throughput:
Operation= 7,022 hr/yr
Annual Sander Production-- 189,016 ODMT/yr
Annual Sander Production--' 151,449 MSF 3/4"/yr
2019 Actual Emissions Summary:
on ro
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 0.90 lbs/hr - 1 6,319.75 lb/ r 3.16 tpy
PM10i2.5 0.90 lb/hr 1 6,319.75 lb/yr 3.16 tpy
VOC 1.11E-02 lb/MSF - 2 1,682.21 lb/jr 0.84121
Formaldehyde 4.00E-04-lb/MSF - 2 60.58 lb/ r 3.03E-02 tpy
Methanol 1.80E-03 lb/ODMT - 2 340.23 lb/yr 1.70E-01 tpy
References:
1. Emission factors from source testing in 2003. All PM is assumed to be PM2.5-
2. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part
III—Medium Density Fiberboard(01/1999),Table 5.2.4,Miscellaneous Source Emissions, Mill 132 (Primary Sander
Baghouse Exhaust).
VOC: Converted from VOC as C to VOC as propane+methanol+formaldehyde.
1 of 1 MDF-ES-08
PB and MDF,.Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Saw System Filter(Diagonal Saw,Trim Saw,Finishing Saws)
Equipment ED Number: ES-07
Emission Point: EP-07
Control Device: CD-07
2019 Actual Process Throughput:
Operation= 7,022 hr/yr
.gal Trim Reclaim(3%of Press Production)= 4,543 MSF 3/4"/yr
Annual Trim Reclaim= 5,670 ODMT/yr
2019 Actual Emissions Summary:
on ro
Efficiency Uncontrolled and Controlled
Compound Emission Factor M Reference Emissions
PM 0.84 lb/hr - 1 5,898.43 lb/yr 2.95 tpy
PM10/2.5 0.84 lb/hr - 1 5,898.43 lb/yr 2.95 tpy
VOC-WPP1 3.74E-01 lb/MSF - 2 1,700.23 lb/ r 0.85
Formaldehyde, I 1.80E-02 lb/ODMTj 2 102.07 lb/ r 0.05 t
Methanol 2.50E-01 lb/ODMTI 2 1 1,417.62 lb/yr 0.71 tpy
References:
1. Emission factors from source testing in 2003. All PM is assumed to be PM2.5-
2. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing
Facilities,Part III—Medium Density Fiberboard(01/1999),Table 5.2.4,Miscellaneous Source Emissions,Mill 132
(Saw Reclaim Sysetm Baghouse Exhaust).
VOC: Converted from VOC_as C to VOC as propane+methanol+formaldehyde.
1 of 1 MDF-ES-07
PD and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Sander System No. 1'Exhaust Filter
Equipment ID Number: ES-08
Emission Point: EP-08
Control Device: CD-08
2019 Actual Process Throughput:
Operation= 7,022 hr/yr
Annual Sander Production= 189,016 ODMT/yr
Annual Sander Production= 151,449 MSF 3/4"/yr
2019 Actual Emissions Summary:
o-r ro
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 0.90 lbs/hr - 1 6,319.75 lb/yr 3.16 tpy
PM10 2.5 0.90 lb/hr - 1 6,319.75 lb/yr 3.16 tpy
VOC 1.11E-02 lb/MSF - 2 1,682.21 lb/ r 0.84 tpy
Formaldehyde 4.00E-04 lb/MSF - 2 60.58 lb/ r 3.03E-02 tpy
Methanol 1.80E-03 lb/ODMT - 2 340.23 lb/yr 1.70E-01 tpy
References:
1. Emission factors from source testing in 2003.All PM is assumed to be PM2.5.
2. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part
III—Medium Density Fiberboard(01/1999),Table 5.2.4+,,Miscellaneous Source Emissions,Mill 132 (Primary Sander
Baghouse Exhaust).
VOC: Converted from VOC as C to VOC as propane+methanol+formaldehyde.
1 of 1 MDF-ES-08
PP and NIDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment:Recycled Fiber Silo No. 1 Filter
Equipment ID Number: ES-09
Emission Point: EP-09
Control Device: CD-09
2019 Actual Process Throughput:
Operation= 395 hr/yr
Mat Reject Production 1= 12,606 ODMT/yr
2019 Actual Emissions Summary:
on ro
Efficiency Uncontrolled and Controlled
Compound Emission Factor (%) Reference Emissions
PM 0.02lb/hr - _ 2 7.89lb/yr 3.95E-03 tpy
PM10i2.5 0.02 lb/hr - 2 1 7.89 lb/yr 3.95E-03 tpy
WPP1 VOC 8.79E-02 Ib/ODMTJ 3 1,108.53 lb/yr 0.55
Formaldeh de 8.90E-03 lb/ODMTI 3 112.191b/yr 5.61E-02 tpy
Methanol 6.9013-03 Ib/ODMTJ 3 86.98lb/yr I 4.35E-02 y
References:
1. Source Testing Conducted at the Moncure mill. VOC test data form May 31,2018 testing. Formaldehyde and methanol data from June 13,2018 testing.
[Annual Press Production(ODMT)/Annual Press Hours]*Mat Reject Operation Hours
2. Bin vent filter estimate of 37.5 gr/10,000 DSCFM based on recent permit applications. All PM is assumed.to be PK.5.
3. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing
Facilities,Part III—Medium Density Fiberboard(0l/1999),Table 5.2.3,Former Mat Vacuum System Emissions,
Mill 132.
1 of 1 MDF-ES-09
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Sander System No. 2 Exhaust Filter
Equipment ID Number: ES-10
Emission Point: EP-10
Control Device: CD-10
2019 Actual Process Throughput:
Operation= 7,022 hr/yr
Annual Sander Production-- 151,449 MSF 3/4"/yr
2019 Actual Emissions Summary:
on ro
Efficiency Uncontrolled and Controlled
Compound Emission Factor (%) Reference Emissions
PM 0.45 lb/hr - 1 3,159.87 lb/ r 1.58 tpy
PM10i2.5 0.45 lb/hr - 1 3,159.87 lb/yr 1.58 tpy
WPP1 VOC 1.11E-02 lb/TMSF - 2 1,682.21 lb/yr 0.84
Formaldehyde 4.00E-04 lb/MSF 2 60.58 lb/H 3.03E-02 tpy
Methanol 1.80E-03 lb/MSF - 2 272.61 lb/ 1.36E-01 t
References:
1. Emission factors from source testing in 2003. All PM is assumed to be PM2.5-
2. NCASI Technical.Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,
Part III—Medium Density Fiberboard(01/1999),Table 5.2.4,Miscellaneous Source Emissions,Mill 132(Primary Sander
Baghouse Exhaust).
VOC: Converted from VOC as C to VOC as propane+methanol +formaldehyde.
1 of 1 MDF-ES-10
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Sander Dust Silo No. 1 Filter
Equipment ID Number: ES-12
Emission Point: EP-12
Control Device: CD-1.2
2019 Actual Process Throughput:
Operation= 3,511 hr/yr
Annual Press Dust Silo No.1 Production 1= 8,391 ODMT/yr
2019 Actual Emissions Summary:
Control
Efficiency Uncontrolled and Controlled
Compound Emission Factor M Deference Emissions
PM 0.02 lb/hr - 2 70.22 lb/ r 0.04 t y
PMJ-012.5 0.02 lb/hr - 2 70.22 lb/yr 0.04 tpy
Total VOC/WPP1 VOC 1.11E-02 lb/ODMTI 3 1 93.21 lb/Z 0.05 t
Formaldehyde 4.00E-04 lb/ODMTI 3 3.36 lb/yr 1.68E-03 t
Methanol 1.80E-03 lb/ODMTI 3 1 15.10 lb/ r 7.55E-03 IpX
References: >
1. Sanderdust throughput is assumed to be 7% of annual MDF plant production. Throughput is divided in Half to assume
equal throughput through the two silos.
2. Bin vent filter estimate of 37.5 gr/10,000 DSCFM based on recent permit applications. All PM is assumed to be PM2.5-
3. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,
Part III—Medium Density Fiberboard(01/1999),Table 5.2.4,Miscellaneous Source Emissions,Mill 132 (Primary Sander
Baghouse Exhaust).
VOC: Converted from VOC as C to VOC as propane+methanol+formaldehyde.
1 of 1 MDF-ES-12
PB and NEDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Dry Sawdust Silo Filter
Equipment ID Number: ES-13
Emission Point: EP-13
Control Device: CD-13
2019 Actual Process Throughput:
Operation= 7,022 hr/yr
Dry Sawdust Production 1= 11,988 ODMT/yr
2019 Actual Emissions Summary:
Control
Efficiency Uncontrolled and Controlled
Compound Emission Factor (%) Reference Emissions
PM 0.02 lb/hr - 2 140.44 lb/yr 0.07 t y
PM 10/2.5 0.02 lb/hr - 2 140.44 lb/yr 0.07 tpy
Total VOC/WPP1 VOC 1.01E-02 lb/ODMTI1 3 121.39 lb/ r 0.06121
Methanol I 4.00E-04 lb/ODMTI 1 3 4.80 lb/yr 0.00 tpy
Phenol I 1.80E-03 lb/ODMTI1 3 1 21.58 lbbT 0.01121
References:
1. Dry sawdust throughput based on 5%of annual MDF plant production in ODMT/yr.
2• Bin vent filter estimate of 37.5 gr/10,000 DSCFM based on recent permit applications. All PM is assumed to be PM2.5.
3. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part
III—Medium Density Fiberboard(01/1999),Table 5.2.4,Miscellaneous Source Emissions, Mill 132 (Primary Sander
Baghouse Exhaust). -
VOC-. Converted from VOC as C to VOC as propane+methanol+formaldehyde.
1 of 1 MDF-ES-13
PB and N1DF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Recycled Fiber Silo No.2 Filter
Equipment ID Number: ES-15
Emission Point: EP-15
Control Device: CD-15
2019 Actual Process Throughput: YF;
Operation= 395 hr/yr
Mat Reject Production ' 12,606 ODMT/yr
2019 Actual Emissions Summary:
Control
Efficiency Uncontrolled and Controlled
Compound Emission Factor (%) Reference Emissions
PM 0.02 lb/hr - 2 . 7.89 lb/yr 0.00 t y
PM10i2.5 0.02 lb/hr - 2 7.89 lb/yr 0.00 tpy
WPP1 VOC I 8.79E-02 lb/ODMTI 3 1 1,108.53 lb/ r 0.55 t
Formaldehyde 8.90E-03 lb/ODMTI 3 1 112.19 lb/ r 0.06 t y
Methanol 6.90E-03 lb/O MTJ 3 86.98 lb/ r 0.04 tpy
References:
1• Recycled fiber throughput calculated by multiplying the annual MDF plant production by the ratio of the material reject
system operating time to the forming line operating time.Throughput is divided in half to assume equal throughput
through the two silos.
2. Bin vent filter estimate of 37.5 gr/10,000 DSCFM based on recent permit applications. All PM is assumed to be PM2.5-
3. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,
Part III—Medium Density Fiberboard(01/1999), Table 5.2.3,Former Mat Vacuum System Emissions,Mill 132.
VOC: Converted from VOC as C to VOC as propane+methanol+formaldehyde.
1 of 1 / MDF-ES-15
PD and AIDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Sander Dust Silo No.2 Filter
Equipment ID Number: ES-17
Emission Point: EP-17
Control Device: CD-17
2019 Actual Process Throughput:
Operation= 3,511 hr/yr
Annual Press Dust Silo No.1 Production 1= 8,391 ODMT/yr
2019 Actual Emissions Summary:
Con
Efficiency Uncontrolled and Controlled
Compound Emission Factor (%) Reference Emissions
PM 0.02 lb/hr - 2 70.22 lb/yr 0.04 t y
PM 10/2.5 0.02 lb/hr - 2 70.22 lb/yr 0.04 tpy
Total VOC/WPP1 VOC 1.11E-02 lb/ODMTI 3 93.21 lb/ 0.05 t
Formaldeh de 4.00E-04 lb/ODMT 3 3.36 lb/yr 1.68E-03 t y
Methanol 1.80E-03 lb/ODMTI 3 1 15.10 lb/ r 0.01 t
References:
1. Sanderdust throughput is assumed to be 7%of annual MDF plant production. Throughput is divided in half to assume
equal throughput through the two silos.
2. Emission factors from source testing in 2003.All PM is assumed to be PM2.5.
3. NCASI Technical Bulletin 770,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,
Part III—Medium Density Fiberboard(01/1999),Table 5.2.4,Miscellaneous Source Emissions,Mill 132 (Primary Sander
Baghouse Exhaust).
VOC: Converted from VOC as C to VOC as propane+methanol+formaldehyde.
1 of 1 MDF-ES-17
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipmer Ness Burners
Equipment ID Number:ES-18,ES-19,ES-20
Emission Point: EP-18,EP-19,EP-21
Control Device: N/A
2019 Actual Process Throughput:
Boiler Natural Gas Throughput= 103 MMscf/yr
Boiler Natural Gas Throughput= 104,576 MMBtu/yr
Natural Gas Heating Value= 1,020 Btu/scf
2019 Actual Emissions Summary:
Control
Efficiency Uncontrolled and
Compound Emission Factor M Reference Controlled Emissions
PM 7.45E-03 lb/MMBtu 1 0.39 tpy
PM10 7.45E-031b/MMBtu - 1 0.39 tpy
PM2.5 7.45E-03 Ib/MMBtu - 1 0.39 tpy
VOC 5.88E-051b/MMBtu - 1 0.00 tpy
CO 8.24E-021b/MMBtu - 1 4.3IE+00 tpy
NO, 9.80E-021b/MMBtu - 1 5.13 tpy
SO2 5.88E-05 lb/MMBtu - 1 3.08E-03 tpy
Lead 4.90E-07 lb/MMBtu 1 2.56E-05 tpy
CO2e _ 2 6,123 tpy
CO2 116.98 lb/MMBtu 3 6,116 tpy
CH, 2.20E-03 lb/MMBtu 3 0.12 tpy
N2O 2.20E-04lb/MMBtu 3 0.01 tpy
pound/year
Arsenic 2.0E-04lb/MMscf 4 1.03E-05 tpy 0.0205
Benzene 2.1 E-03 lb/MMscf 4 1.08E-04 tpy 0.2153
Beryllium 1.2E-05lb/MMscf 4 6.15E-07 tpy 0.0012
Cadmium l.1E-03lb/MMscf - 4 5.64E-05 tpy 0.1128
Chromium 1.4E-03lb/MMscf - 4 7.18E-05 tpy 0.1435
Cobalt 8.4E-051b/MMscf - 4 4.31E-06 tpy 0.0086
Formaldehyde 7.5E-02lb/MMscf 4 3.84E-03 tpy 7.6894
Hexane 1.8E+00lb/MMscf - 4 9.23E-02 tpy 184.5455
Manganese 3.8E-041b/MMscf - 4 1.95E-05 tpy 0.0390
Mercury 2.6E-04lb/MMscf - 4 1.33E-05 tpy 0.0267
Naphthalene 6.1E-04 lb/MMscf - 4 3.13E-05 tpy 0.0625
Nickel 2.1E-03lb/MMscf - 4 1.08E-04 tpy 0.2153
POM 6.28E-04 lb/MMscf - 5 3.22E-05 tpy 0.0644
Selenium 2.4E-05 lb/MMscf - 4 1.23E-06 tpy 0.0025
Toluene 3.4E-03lb/MMscf - 4 1.74E-04 tpy 0.3486
Zinc 2.9E-02 lb/MMscf 4 1.49E-03 tpy 2.9732
References:
I. Emission factors based on AP-42,Chapter 1,Section 4.All PM(total,condensible,and filterable)is
assumed to be less than 1.0 micron in diameter. Units are conveted from lb/MMscf to lb/MMBtu by
dividing by a factor of 1,020. NCB and CO emissions are based on emission factors from small
uncontrolled boilers(<100 MMBtu/hr).
2. Global warming potentials are obtained from 40 CFR 98,Subpart A,Table A-1:
CO2: 1
CH4: 25
N2O: 298
3. Emission factors based on 40 CFR 98,Subpart C,Tables C-1 and C-2 for Natural Gas..
4. Emission factors obtained from AP-42,Section 1.4,July 1998,Tables 1.4-3 and 1.4-4.
5. POM=PAC(NCASI SARA guidance)+naphthalene
7 of I MDF-ES-18,19,20
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: MDF Emergency Generator(Diesel)
Equipment ID Number: ES-21
Emission Point: EP-21
Control Device: N/A
2019 Actual Process Throughput:
Hours of Operation= 14.0 hr/yr
HP Rating= 1;592 hp
Annual Output= 22,288 hp-hr
2019 Actual Emissions Summary:
Control
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 2.20E-03 lb/h -hr 1 49.03 lb/yr 0.02 tpy
PMmnS 2.20E-03 lb/hp-hr 1 49.03 lb/yr 0.02 tpy
S0, 2.05E-03 lb/hp-hr 1 45.69 lb/yr 0.02 tpy
NOx 3.10E-02 lb/hp-hr 1 1 690.93 Ib/yr 0.35 tpy
VOC 2.47E-03 lb%hp-hr 1 55.05 lb/yr 0.03 tpy
CO 6.68E-03 lb/h -hr 1 148.88 lb/yr 0.07 tpy
Acetaldehyde 1.76E-07 lb/h -hr 1 3.93E-03 lb/yr 1.97E-06 tvy
Acrolein 5.52E-08 lb/h -hr 1 1.23E-03 lb/yr 6.15E-07 tpy
Arsenic unlisted 2,80E-08 lb/hp-hr 1 6.24E-04 lb/yr 3.12E-07 tpy
compounds
Benzene 5.43E-06 Ib/hp-hr 1 1.21E-01 lb/yr 6.05E-05 tpy
Benzo(a)pyrene 1.80E-09 Ib/hp-hr 1 4.01E-05 Ib/yr 2.00E-08 tpy
Beryllium metal, 2.10E-08lb/hp-hr 1 4.68E-041b/yr 2.34E-07 tpy
unreacted
Cadmium metal 2,10E-08 lb/hp-hr I 4.68E-04 Ib/yr 2.34E-07 tpy
elemental unreacted
Chromic Acid(VI) 2.10E-08 lb/h hr 1 4.68E-04 lb/yr 2.34E-07 tpy
Formaldehyde 5.52E-07 lb/h -hr 1 1.23E-02 lb/yr 6.15E-06 tpy
Lead and Lead 6.30E-08 lb/hp-hr I 1.40E-03 lb/yr 7.02E-07 tpy
compounds
Manganese unlisted 4.20E-08 Ib/hp-hr 1 9.36E-04 lb/yr 4.68E-07 tpy
compounds
Mercury vapor 2.10E-08 Ib/h -hr 1 4.68E-04 lb/yr 2.34E-07 tpy I
Na thalene 9.10E-07 lb/h -hr I 2.03E-02 lb/yr 1.01E-05 tpy
Nickel metal 2.10E-08 lb/11 -hr 1 4.68E-04 lWyr 2.34E-07 tpy
Selenium compounds 1.05E-07 Ib/h -hr 1 2.34E-03 lb/yr 1.17E-06 tpy
Total PAH 1.48E-06 lb/h -hr 1 3.31E-02 lb/yr 1.65E-05 tpy
Toluene 1.97E-06 lb/h -hr 1 4.38E-02 lb/yr 2.19E-05 tpy
X lens 1.35E-06 lb/h -hr I I 3.01E-02 IbLLr 1.51E-05 tpy
References:
1. Emission factors obtained from NC DAQ spreadsheet for calculation of air emissions from internal combustion engines.
1 Oft MDF-ES-21
P)B and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: resin Tanks
Equipment ID Number: MDFR-1,MDFR-2,MDFR-3
Emission Point:
Control Device: N/A
2019 Actual Process Throughput:
Number of Tanks= 3.0 #
Actual Hours of Operation= 8,760.0 hr/yr
2019 Actual Emissions Summary:
on ro
Efficiency Uncontrolled and Controlled
Compound Emission Factor M Reference Emissions
VOC - 0.0012 lb/hr/tank - 1 31.54 lb/yr 1.58E-02 tpy
lb/yr
Formaldehyde 0.001 lb/hr/tank - 1 26.28 lb/yr 1.31E-02 tpy 26.28
Phenol 0.0002 lb/hr/tank - 1 5.26 lb/yr 2.63E-03 tpy 5.26
References:
1. Emission Factor based on 40 CFR 63 Subpart DDDD,Plywood and Composite Wood Products (PCWP)
Rule,Table 2A.
1 of 1 MDF-I-MDFR-1-4
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Spray Fields
Equipment ID Number: I-Irrigation fugitive
Emission Point:
Control Device: N/A
2019 Actual Process Throughput:
Spay and Pond Concentration= 0.2 mg/L
1.67E-06 Ib/gal
Gallons Irrigated= 2,295,500.0 gaVyr
2019 Actual Emissions Summary: r
Control
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
VOC 1.67E-06 lb/gal - 1 3.83 Ib/ r 1.92E-03 tpy
Formaldehyde 1.67E-06 lb/gal - 1 3.83 lb/yr I 1.92E-03 tpy
References:
1. Concentration from 2011 Formaldehyde test.Using half of detection limit since concentration was below the detection limit of
0.4 mg/L.
1 of 1 MDF-Irrig
S
$o................
T 44=� =4� ^444g4�444v$g4c`44� _ ci g� gYYYQYY Y I Y Y YY YY YY
o� ` woww uw �uw u��_;oowrn�'`�n ucu o,E wwu wwwuw w we w u wwu 1PIT
12
y_o
64 -�fj-
a U
_ C
R If
""�
c�o�i P c m �R Ems'y`'NY,y 6�u zA�� _ - __ -
n n 2 c a r c
R"w uu uu u _ u uu 44 ,wnw4ww - w - Rgg
z 4R
'oa 5,'S,
'E tbzz M _ „3�= _ �� off'-e_ _
5 pEp=q j +" UU J
w..2 _ -F . 0 E 2 " -__ ' 00 . 0.�O �E E E< E a c F u_c u u o
auz.n. uz Zmn'ciu c�uo FFz z=yrN „a 7'- `�0 xoRuz .� uuz' � mm 5i�5�u�cc°.E z`'Z� �:,FK „i7�V
' s
E;ms o6aoosoo
�0000000-00000000
gg4444�q$Qv�4� � E ��_ RYYYYgQ Y Y Y Y YYY
www wwu ww w n w ww w m u w wwm w www .
6. _ � -------- ----- ti
V s U
Till,t -
0
e v ..0 C o- a o v S'.y&"`✓v"' YV v " _-'�E -�u z.9
c c cc c c c caa �.Q
a_ ° a4R4vv4 94444494 --- �$ 44 3 �4
6 ww w wm w w u. _w w- owwwoo na m�r?wmTec �q yZ o "c = .s - uww w oww
Q, gg'
.ii
aD<
y•• , ���c E c a C�,�S m C�� E � <� 5 E _ �o� ,
zAS
o"" '° g a` �€ e �� 000y oo
auzw uu uZ' Zn z Z ^
auz� `uui�X"
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Press and Board Cooler
Equipment ID Number: DEF-2010,PB-BC
Emission Point:
Control Device: N/A -
2019 Actual Process Throughput:
Press Production= 138,792 MSF 3/4"/yr
Press Operation= 6,097 hr/yr -
Avg Hourly Press Production= 22.8 MSF 3/4"/hr
Abort/Bypass Operation= 6,097 hr/yr
2019 Actual Emissions Summary:
Control
Press Board Cooler Efficiency Press Board Cooler Uncontrolled and Controlled
Compound Emission Factor Emission Factor (%) Reference Reference Emissions Press tpy BC typ
PM 3.391b/hr 0.23 lb/MSF - 1 5 52,175 lb/ r 26.09 tpy 10.334415 15.753
PM'o 3.39 Ib/hr 0.23 lb/MSF - 1 5,6 52,175 lb/yr 26.09 tpy 10.334415 15.753
PM'.S 1 1.17 lb/hr 0.08 lb/MSF - 1 1 5,6 1 17,8201b/yr 8.91 tpy 3.566745 5.343
NO, 0.40 Ib/hr - lb/MSF - -1 1 N/A 12420.51 lb/yr 1.21 tpy 1.2102545 #VALUE!
CO 0.04lb/hr 0.15 lb/MSF - 1 5 21,063 lb/ r 10.53 tpy 0.12194 10.409
WPPI VOC 1.60 Ib/hr 0.13 lb/MSF - 3 5,7 240,802 lb/ r 1 120.40 tpy 4.88092242 9.292
Press lb/yr BC Ib/yr
Acetaldehyde 1.04E-01 lb/hr 1.30E-03 lb/MSF - 1 8 814.52 Ib/ r 0.41 tpy 634.09 180.43
Acrolein 2.30E-02lb/hr 3.60E-04lb/MSF - 3 8 190.20lb/ r 0.10 tpy 140.23 49.97
Cumene 5.48E-05 lb/MSF 5.48E-05 lb/MSF - 1 4 15.21 Ib/ r 0.01 tpy 7.61 7.61
Formaldehyde 1.59 lb/hr 0.03 lb/MSF - 3 8 1.3,442 Ib/ r 6.72 tpy 9694.23 3747.38
Methanol 4.20 Ib/hr 0.05 lb/MSF - 3 8 33,102 lb/ r 16.55 tpy 25607.40 7494.75
Methyl Ethyl Ketone 9.30E-04 lb/MSF 1.10E-04 lb/MSF - 2 5 144.34 lb/ r 0.07 t y 129.08 15.27
Phenol 1.65E-01 lb/hr 4.70E-03 lb/MSF - 3 8 1658.33 lb/ r 0.83 tpy 1006.01 652.32
Pro ionaldeh de 1.70E-02 Ib/hr - lb/MSF - 1 N/A 103.65 lb/ r 5.18E-02 tpy 103.65 #VALUE!
References:
1. December 21,2005 Stack Testing. Assume P4=PM,and assume PM>.5=condensible PM.
2. Emission factor obtained from NCASI TB 771,Table 6.3.1,January 1999.
3. VOC is WPPI VOC=VOC as propane+methanol+formaldehyde-0.65*methanol.Methanol and formaldehyde values from July 2018 stack test,VOC from 2005 stack test.
4. NCASI emission factor database cumene emissions from PB dry material dryer* 1.5 ODMT/MSF.
5. AP-42 Wood Products Industry-Particleboard Manufacturing, 10.6.2 June 2002.
6. Assume PM10=PM,and assume PK.5=condensible PM.
7. July 2018 stack test.VOC is WPPI VOC=VOC as propane+methanol+formaldehyde-0.65*methanol.
8. Emission factors obtained from NCASI SARA 313 Guidance Updated 2011 -Median Values.
1 of 1 PB-Press
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: i PB Plant Wcllons Furnace
Equipment ID Number: 3201(1420 or 1430)
Emission Point:
Control Device: N/A
2019 Actual Process Throughput:
Heat Input°= 40.0 MMBtu/hr
Heating Value of Wood= 8,000.0 BnJlb dry basis
Calculated Firing Rate= 0.0 ton(hr
Wellons Gas Consumed= 13.8 MMscf/yr
Wellons Bypass Hours= 6,097.0 hr/yr
Heating Value of Green Wood= 8.7E-03 MMBt✓Ib
Bypass Wood Combusted= 0.0 Ib/yr
Bypass Wood Combustion= 0.0 MMBht/yr
2019 Actual Emissions Summary:
Emissions from Wood:
rat ru
Efficiency Uncontrolled and Controlled
Compound Emission Factor (%) Reference Emissions
PM 5.60E-01 IbfMMBtu 1 0.00 Ib/r 0.00 ray
PMio 5.00E-01 lb/MMBtu 1 0llo lb/yr 0.00 lay
PM,' 4.30E-01 Ib/MMBm 1 0.00 lb/yr 0.00 toy
CO 6.00E-01 Ib/MMBtu 1 0.00 Ib/r 0.00 lay
NOx 3.30E-01 Ib/MMBt) 1 0.00 Ib/r 0.00 tov
SO,. 2.50E-021b/MMBIu 1 0.0016/yr 0.00E+00 toy
VOC 1.70E-02 Ib/MMBm I 0.00 Ib/r 0.00E+00 lay
Lead 1.77E-05 Ib/MMBtu 4 0.00E+00 Ib/r 0.00E+00 toy
Acetaldehyde 1.22E-04 Ib/MMBtu 2 0.00E+00 Ib/r 0.00E+00 lay
Acrolain 3,16E-05 Ib/MMBm 2 0.00E+00 Ib/r 0.00E+00 tpy
Antimony 4.23E-07 Ib/MMBm 3 0.00E+0Q Ib/r 0.00E+00 toy _
Arsenic 3.02E-06 Ib/MN1Btu 4 0.0013+00 lb/yr 0.00E+00 toy
Benzene 2.35E-04 lb/MMBm 2 0.00E+00Ib r 0.00E+00 tpy
Benno a rene 2.60E-06 Ib/NIMBm l 0.00E+00 lb/yr 0.00E+00 tpy
Beryllium 4.27E-05 lb/MMBm 4 O.00E+00 Iblyr 0.00E+00 tpy
Cadmium 4.67E-06 Ib/MMBtt 4 0.00E+00 Ib/r 0.00E+00 lay
Chlorine 7.90E-04 Ib/MMBtuu 1 0.00E+00 Ib/r 0.00E+00 toy
Chlorobenze 1.66E-05 Ib/IvlMBm 2 0.00E+00 Ib/r 0.00E+00 my
Chloroform 3.52E-05 Ib/MMBtu 2 0.00E+00 Ib/r 0.00E+00 toy
Chromium 3.46E-05 Ib/MNIBtu 4 0.00E+00 Ib/r 0.00E+00 tov
Chromium VI 6.97E-061b/MMBm 4 0.00E+00 Ib/r 0.00E+00 toy
Cobalt 1.96E-05 Ib/MMBm 4 0.00E+00 Ib/r 0.00E+00 toy
Eth(benzene 1.76E-05 Ib/I IMBtu 2 0.00E+00 Ib/r 0.00E+00 toy
Formaldehyde 8.83E-04 Ib/MMBm 2 0.00E+00 Ib/r 0.00E+00 tpy
Hydrogen Chloride 1.57E-03 Ib/MMBtu 2 0.00E+00 Ib!r 0.00E+00 tov
Manganese 1.81E-03 Ib/MMBm 4 0.00E+00 Ib/r 0.00E+00 toy
Mercury 5.00E-07 Ib/MMBtu 4 0.00E+00 Ib/r 0.00E+00 tpy
Methyl ethyl ketone. 5.39E-06 Ib/MMBm - 2 0.00E+00 Ib/yr 0.00E+00 tpy
MEK
Naphthalene 7.44E-05 Ib/MMBtu 2 0.00E+00 Ib/r 0.00E+00 ray
Nickel 2.26E-05 Ib/MMBtu 4 0.00E+00 lb/yr 0.00E+00 tpy
Phenol 1.98E-05 Ib/MMBm 2 0.00E+00 Ib/r 0.00E+00 ray
POM 1.06E-04 Ib/MMBm 1.2 0.00E+00 Ib/r 0.00E+00 lay
Selenium 2.53E-06 Ib/MMBtu 4 0.00E+00 Ib/r 0.00E+00 1py
Trichloro0uoromethane 4.05E-05 Ib/MMBm 2 0.00E+00 Ib/r 0.00E+00 1py
Styrene 6.30E-05 Ib/MMBm - ! 2 0.00E+00 16/r 0.00E+00 tpy
Toluene 2.34E-05 lb/MMBm 2 0.00E+0016f 0.00E+00 lay
X lene 5.22E-06 Ib/NINIBm 2 0.00E+00 Ib/r 0.00E+00 lay
Emissions from NG:
Compound Emission Factor Control Reference Uncontrolled and Controlled Emissions
Efficiency
%)
PM 7.60 Ib/MMscf 5 105 lb/yr 0.05 tpy
PMjo 7.60 Ib/MMscf - 5 105 Ib/yr 0.05 tpy
PM._.s 7.60 Ib/MMscf 5 I05 Ib/yr 0.05 tpy
CO 84.00 Ib/MMscf 5 1,161 Ib/r 0.58 toy
NOx 100.00 Ib/NrMscf 5 1,383 lb/yr 0.69 lay
S02 0.60 Ib/MMscf - 5 8 Ib/yr 0.00 toy
VOC 5.50 Ib/MMscf 5 76 Ib/r 0.04 tpy
Lead 5.00E-04 Ib/MMscf 5 0.01 Ib/r 3,46E-06 toy
Ib/yr
Arsenic 2.00E-04 Ib/MMscf 5 0.00 Ib/r 1.38E-06 toy 0.002765
Barium 4,40E-03 Ib/MMscf 5 0.06 Ib/r 3,04E-05 toy 0.060839
Benzene 2.10E-03 Ib/NlMscf 5 0.03 lb/yr 1.45E-05 lay 0.029037
Cadmium 1.10E-03 Ib/MNtscf 5 0.02 Iblyr 7.60E-06 toy 0.015210
Chromium 1.40E-04 Ib/MMscf 5 0.00 Ib/r 9.68E-07 my 0.001936
Cobalt 8.40E-05 Ib/NIMscf 5 0.00 Ib/r 5.81E-07 lay 0.001161
Formaldehyde 7.50E-02 Ib/MMscf 5 1.04 Ib!r 5.19E-04 tpy 1.037026
Manganese 3,80E-04 Ib/MMscf 5 0.01 Ib/r 2.63E-06 toy 0.005254
Mercury 2.60E-04 Ib/MMscf 5 0.00 lb/r LM-O6 0.003595
Na hd)alene 6.10E-04 Ib/NINiscf 5 0.01 Ib/r 4.22E-06 0.008434
Nickel 2.10E-03 Ib/MMscf 5 0.03 Ib/r 1.45E-05 my 0.029037
Toluene 3.40E-03 Ib/MMscf 5 0.05 Ib/r 2.35E-05 toy 0.047012
References:
1.Emission factor obtained from AP-42,Section 1.6,09/03,Wood Residue Combustion in Boilers,Tables 1.6-1-3.
2.Emission factor obtained from NCASI TB 973,Table 7.1 Uncontrolled,February 2010.
3.Emission factor obtained from NCASI TB 973,Table 7.2 Control:Fabric Filter,February 2010.
4.Emission factor obtained from NCASI TB 973,Table 7.2 Control:Mechanical Collector,February 2010
5.AP-42 Section 1.4.July 1998.
6.Wellons contributes 24 MMBtdhr to Core Layer Dryer(74 MMBttdhr total,normal operation)and contributes 16 MMBm/hr to
Surface Layer Dryer(56 MMBtt/hr total,normal operation).Beginning July 2007 exhaust from this source goes through the PB
dryers and Wet ESP.However,during startup,the exhaust is bypassed to atmosphere.As designed,this bypass occurs for 0.25-0.5
hour prior to dryers being started.The emissions are counted in the dryers exhaust except startup.Startup emissions are accounted
for in this calculation.
1 or 1 Pa-Woliona Furnace
' 1'0 avd NIDF,NIwwn,XC
Peruilr\'umber OJJJ9T51
Emtzdov UWl Equip- PB M.Porlleleb0vrd D-
EqWpmeulNXumbrr; 1430,1420,3201(1 Cure Lvyrr DrSer,I S d-Layer DO'er,eW%%Vella.)
Dmivlav NM':
Camr91 D-1 . C0.1431,CDM-\UP,CD-1421
2019.4mOl Pe -Tbr hpul:
Drym Pmducliw- 138,192 NISF 3/4-/yr
173,7M OD%ffl r '
PBB a-Y- 44.5 Wit,
DyZ0,-6ov11 - 6,097 bnyr
IlofvH W..ofG-Wood- 0.008)NMBOS
If.,Fucl and Swdmdusl Combuafov- 76,733,6198 Ibyr
v'uwrd Oaa UmBvlbaclmpl- 1.61 M\IwFYr '
FbB Fucl and SavJadusl Combustion- 667.E .6 NWBwyr
N.-I Gaz 11.9.,Value- 1,020.0 Bm'xf
Told D;a It-lnpol- 160\L\IDmLr
Xawm1°.U(bucf;p)- 10.3 bryr
2019 M-I EOIUU.Hummarr:
\Vuvd Xawrat G. ENulco<5' Woad arum%Gva K'vvd Uvc"vtmlleduvvd CvvmBrd Taml
Cvm avvd Emlal9v!'vemr Emhzlou F9clar (•/.) Referrmx Refercvve CvvmvDcd EmWam Emlo-zlvm Cu94ro1lcd Emizdom
Pm(wm11 &W @fir 7-MNINxf 2 1 54,111.2 Ibr 27A6 Ul 12.11 Ibr 001 U, 14.123 Ibbr 27A6 1 v -
P.M-" ,ible,OUT 6.54 Mhr ib1131zer E 1 _ 39.8073 M 19,90 M r 39307 Ibvr 1-0
PN filtmbl<OUT 235 @fir MNf\1xf - 'E 1 14303.9 Ibr 7.15 s Ib'r ICM0 1-, 1.15
PM,.fuull &89 lhlr 7.6016NOfxf 2.IS I 34.111.2 My, 27.06 V, 1122 M 0.01 v 543D Ibr 27.06
P\2�„wvdcvsible.lamll 634 Mlsr MNLlxf - 2 1 3980I.1 Ib'r 19.90 M' 39,807 Ib WA v -
PM„filxmble.OUT, 2.15 Ibbr - MNLNwf 2 1 2430},9 Ib:r 7.13 1 ih'r 14304 Ibvr 7.15 I
py
P\I-,som11 &89 Mfir 160 MW.f 2,3 1 54.1111 @ 27.06 i 12.22 Mvr Oal 0, 54.123 lb'r 27.06
P.N-.wMwdble,mml 6.54 @'hr - I6111xr 2 1 39.807.3 Myr 19.90 v Ib'r 311.907 Ibvr 19.90 y
PN._.fihmablc.r9ml1 2.02 lbbr Ib\Mxf 2.3 1 133013 Ibl'\m 6.15 v .Ib 12101 @ r 6.15 I v
.NO, 56.70 Mlu 50,00 MABIwf 2 1 N$J I8.7 M 17216 v 80.39 Ib' 0.04 345.1W My, 172.0ipy
CO 123.70 Iblu KIM MNlllzef 2 1 ]65.101.5 Mvr 382.55 135.06 Ib'r 0.07 I 765140 @ r 38+.62 1 v
8Ov 0.0I I6-hr 0.60 IbNlNlxf 4 I 152.2 @ r 0.08 0.96 M'r O.Ou v ISJ I6'r 0.08 v '
VOC aeC JO30 166r. - IbNL\Ixf 2 1 24519b.0 1b IL+,65 Ibr 2"'6 @vr 12L63 r
VOC va Pm ane 49.26 IT,lv - M"VIlwf Cnlculamd 1 299.806.3 MY, 139.90 0, M r I299.8o6 Ibvr 149.90 i
IVPPI VOC Sl.]I Ibfir - Ib1LNfxf 2 6 326,9 3 Ibvr 16J.4f M r 326"Ibvr 163.43 s
Lead 4.951A6 M 1 9 1 330E1�16vr 1.63M3 M'vr 3Ib'vr L65EA3
s...•Idchvd< 1.06E•00 IbN - Ib1LNwf 5 1 6.41-3 MW 3.23E+00 Ibr 6452 M'yr 3.23 Ov .32
A-m 1.62EA4 @h1.1113w - M1Llfscf 7 1 1.08EW2 Ibr 5AIE4)2 v Ib'r loe Ib'r 0.05 v I0H.15
Arcmnc au 1.91E-02 @fir - Ib1L\Iwf 8 1 1.20E-Ibr 5.98EA2 1 r 120 @lr 0.06 v 119.69
A.Icio 3.25EAl Whr Ib1L\Iwf 3 1 1.98EW316' 9.H9E01 Ih'r 1978@vr 0.99 19]8.2
Arsenic 3.21EA7 MNMBw - MNI\Iwf 9 1 2.14E-01 4W 1.07E44 JO, WYr 2.14EA1 1 r 1.07EA4 v 0.2143
Bcmme 2.33Fi04 @NINBm 2.IOEAI Ib\I\Ixf ] 1 ISM-Ib 7.84E-02 338E-03 Ib'r L69E-W 1 v 157 Ib'r 0.08 I 156.89
Dcum(a) 2.60EA6 @M1L\1Bw I.±oE-06 WN.Nxf 45% I 955E-01 Ibr 4.JIEA4 LO6E-06 @'r 531E-I0 116 437E61 t 0.934]
Bmmivu 2.44E-03 Id\D1Bw Ib'3f31xf I 1.6313 01 Ibr r H.14E-03 W r 16 1 0.01 i 16.2]J
Cadmium 3.)lE-07 Ih\L\IBw IbNLNxf 1 2.JWE Ibvr 1.25EA4 v Mw 2,49EA1 Ibvr 1.25E-0, 0.241
Chlorine 7.90E-04 MIL11Dw lhll\Ixf - 4 I 517E+03 Ibvr 2.64E-01 U, M'r 527 Ibvr 0.M 527.4
Chlm9fazm 2.80E-05 Mh L\ft{w IbNiNiwf - 4 1 117-1 Myr 9.35E43 Uy @ r 19 16 r 0.01 Oy t&693
Chmmium S.u4E-07 M\MlBw Mlillxf 9 1 537MI IWw 2.6812 4 1 Ib r 5.37E-01 1- 2.68E-01 I OS368
Chromium VI 2.73EAI I6MNIBm IbMNxf 9 1 1.82E-0I Ibr 9.08EAJ Ib v 1.82E-01 Mvr 9.08EA3 0.1816
C It 4.68E07 MMMB. 8.40FA5 MN1Mwf 9 I 3.12EOI M r 1.56EA4 L33E-04 M'r USE- v 3,13E01 lb 1.56E-04s 03126
Cumwe 339E-03 MODNIT I1,1131wf 10 I 5,89E-02 MM 2.94E-01 Wvr 589 Ibvr 0.29 589.99
F.-I,e ,O 2.24E.00 Ibbr 7.50E-02 IhMNxf 5 1 1.361104 IV,, 6.82EM0 I v 1.21E41 MNr 6.03E-05 0, 13,634 Ibr 6.82 s 13634
II dm tlsloddc 1.57E-03 MNMBW IbN!\twf 7 1 1,05E•o3 M'r 5.24E-0I Ibvr I-.8 Ibvr 0.32 v 1048.1
Mau•avme JSOE-0S IbNINDw IbNlNlxf 9 1 2.34EM1 1b'vr 1.17E-02 M r 23 1h r 1.17E02 - 23.366
\IMmml 3.1711 0 Mfir IhNM1xf 5 I 1.93E+04 M r 9.65E400 Ib'r 19.295 Ibvr 9.63/ 19295
\INmirot va 1.45E400 @fir - MNMxf - 8 1 8.84E+03 M 4.42E+00 v Ibr Im S.SU lb- 4.4s 9.3.1
Mmwry 4.02E47 MMMUw Mml.f - 9 1 2.68EA1 Ibvr 134E-04 v Ib'r U,
2.68EA1 Mvr 134E04 v 0.2694
\Idyl ethyl lOO,O(NIIX) 9.60E-03 M'ODNIT - Ib'\f\fxf 11 I 1.67EM3 Ibvr 834EA1 by - Myr - 1.66.Mb r 0.81 1667.6
NnhyllmburyllCct°"` 1.40E-03 I6DD\1T - Ih1Mxf 2,43E+02M 1.22E-01 - Ib' - 243 M' 0.12
'Ie11 1 K n r` n&
\IcW Iwv Chlodde 330E04 @NINBm - IMLNwf 7 1 234E402 Ibr 1.17EA1 I r 234 Ibr 0.12 v 111.66
n-Raavc 2.88E-04 MNIMBm I.BOF.400 MI Nxf - 7 1 1.92E.02 Ibr 9.61EA2 2.89E+00 Ibr IA5E03 Uy 195 Mvr 0.10 0, 195.16
hlw- 7,44E05 MNLV1Bw 6.10EA4 NNLllxf 45X 7 1 2.7311-Ibr 1.37E-02 539E-04 M'vr 2.7011-U, 27 Ibvr 0.01 0, 27.30 -
Niekcl 343G WUMBO Ib11Mxf 9 1 2,30E10 I r 1.11EA3 s v W r 2 1-1 I.ISEAI 2.3032
Phuwl 2.3HE01 Ibbr IbN\Ixf 5 1 1.4513 01 M'r 7.24E41 It I.-@' 0.7E Vy 1449.E
MM 114E04 MNIMBW Ibllll.f 4 1 1.16EM2 My, 5.80E-02i 16'vr 116 Wvr 0.0E TO, 116 _
P awl 3.20E-06 IhNINIBm Ib:NNlxf 4 1 2.14E•00 M'r 1.01E-03 Ibvr 2 Ibvr 1.07E-03iv 2.1363
P iowldchvda 930F.-01 Mhr MNINxf 5 1 5.MEW2 Mvr 2.83EAI Oy M'vr 50 @vr 0.28 S ..
Selrninm 3.1IEA7 Ib'\I\IBw 2.40EA5 IbNLN1xf I 3.41E-0I MW 1.71E-04 U, 3.86E-05 Ibvr 1.93E-08 3AIE41 Ibvr 1.71E-04 v 03412
5 mac 6.30EA5 Ib\I\2Bw MNIMxf 7 1 4.21Er01 N'r 2.10E-02 Mvr 42 @vr 0.02/ 42D59
Tolurnc 2.34EA5 Ib\L\IBw 1.40EA}WN\1xf _ 7 I L56E401 Ibvr 7.81E-01 5.47EA3 Ibvr ±73EA6 16 @vr 0.01 15.627
X Irne 512EA6 IbNMBw IbM\Ixf - 7 1 3.48E460 Ibvr 134E03 lov M'vr J Ib'vr I.74EA3 v 3.4849
Re(ertvter; ,
1.Emission facwrsobmivd fmm MJ2,CUP-.B 61.4.T9kw fmos DAQV.&h.LJ.ly I"It.
2.Fmissiov Lxton fmmalsskI mg 102009.Asavzdevmb0iblePM.-Mammble P\bn
3.PN1z,uas nolmrnsuml iv We±009 zest Thu mlio of0.86 P\hJp\I�n fmm N'-4±Scdoo 1.6,ioble l.6-I u-ssappBW m We teued Bbcrublc P3l�e value
4.Emission lama.9M1mind fmm M-f25alion 1.6,0903.1Vo0d Residue Camlwstioa
3.Emisdonf-fro RTO Ulas klmtin812-3.
6.%WPI V0 -VOC ar Pmpanc+.11-1+ll.. hyde-0.65emc0urol a1 POP--0.65•accmnem TO,—
7,Emission Faeson obmi.W fmm XCASI TD 973,Tebk 7.1 U'rconwllad,Fc,.q 2010.
8.Am9w sspmpaveand mnbarol as pmpawuem udwlamdand uxJ far W9\YPP1 YOL'eslwtasi0v only.
9.F.miss ft F.-bbi-I fmm RCMI Tit 973,Tablu 7.2 C1"w1:UP.Fc.q 2010. ,
10.Cumwe wiaion fcl°r bi-d fmm\CASTemiman fxmr dambax far, fibezb°md mfizrcruet-1(50%m0i-).
11.zN'Cc\51 TD171,V°Ia6le Oq.6.Compwvd Fmimom fmm IVO Ipmducm\lavufcmdeg F-i-.Pan W-Pmtielebomdf0l/19991.Tvbly 6.2.1.8 if-Pi.Fumidz(Dry),%-.0 Emhs
li.Emission fclor VOC a1VOC(-]firing)=VWa.s pmpwv+Fovwldchydv as Fommldchydc+05e MNmnol oz NlcOmnol
Il.All PNI ZIVBT EST vsmmd a be P\fin
SCASI Tcehniml Della 770,V.hliW OgaOk Compound EmiWs fmm%V9I wet\lanuf sine Farifi6¢Pan III-Nldium .
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: PB Fire Pump
-Equipment ID Number: I-DFP-1
Emission Point:
Control Device: N/A
2019 Actual Process Throughput:
Diesel High Heat Value= 0.138 MMBtu/gal
Hours of Operation= 31.6 hr/yr
Yearly MMBtu Throughput= 76.8 MMBtu/yr
Heat Input I= 2.429 MMBtu/hr
Fuel Consumption 2= 17.6 gal/hr
2019 Actual Emissions Summary:
on ro
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions-
PM 0.31 lb/MMBtu - 3 , 23.79 lb/ r 0.01 tpy
PM10/2.5 0.31 lb/MMBtu - 3 23.79 lb/yr 0.01 tpy
SO, 0.29 lb/MMBtu - 3 22.26 lb/yr 0.01 tpy
NOX 4.41 lb/MMBtu - 3 338.50 lb/yr 0.17 tpy
VOC 0.36 lb/MMBtu - 3 27.63 lb/yr 0.01 tpy
CO 0.95 lb/MMBtu 3 72.92 lb/jr 0.04
Acetaldehyde 7.67E-04 lb/MMBtu - 3 0.06 lb/ r 2.94E-05 tpy
Acrolein 9.25E-05 lb/MMBtu - 3 0.01 lb/ r 3.55E-06 tpy
Benzene 9.33E-04 lb/MMBtu - 3 0.07 lb/ r 3.58E-05 tpy
Butadiene- 1,3 3.91E-05 lb/MMBtu - 3 0.00 lb/yr 1.50E-06 tpy
Formaldehyde 1.18E-03 lb/MMBtu - 3 0.09 lb/yr 4.53E-05 tpy
Napthalene 8.48E-05 lb/MMBtu - 3 0.01 lb/yr 3.25E-06 tpy
POM 8.32E-05 lb/MMBtu - 3 0.01 lb/ r 3.19E-06 tpy
Toluene 4.09E-04 lb/MMBtu - 3 0.03 lb/ r 1.57E-05 tpy
Xylene 2.85E-04 lb/MMBtu - 3 0.02 lb/ r 1.09E-05 tpX
References:
1. Heat input for fire pump calculated by:347 hp-out*7000 Btu-in/hp-hr.
2. Fuel consumption for fire pump was calcultated by 2,429,000 Btu/11r*gal/441,000 Btu.
3. Emission factors obtained from AP-42;Section 3.3,Tables 3.3-1 and 3.3-2' October 1996. All PM is assumed to be
X
1 of 1 PB-I-DFP-1
PD and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: PB Emergency Generator(Diesel)
Equipment ID Number: I-ODG
Emission Point:
Control Device: N/A
2019 Actual Process Throughput:
Diesel High Heat Value= 0.138 MMBtu/gal
Hours of Operation= 8.8 hr/yr
Yearly MMBtu Throughput= 10.4 MMBtu/yr
Heat Input 1= 1..183 MMBtu/hr
Fuel Consumption 2= 8.57 gal/hr
2019 Actual Emissions Summary:
on ro
Efficiency
Compound Emission Factor (%) -Reference Uncontrolled and Controlled Emissions
PM 0.31 lb/MMBtu - 3 3.23 lb/ r 0.00 tpy
PM10i2.5 0.31 lb/MMBtu - 3 3.23 lb/yr 0.00 tpy
SOZ 0.29 lb/MMBtu - 3 3.02 lb/yr 0.00 tpy
NOX 4.41 lb/MMBtu - 3 45.92 lb/yr 0.02 tpy
VOC 0.36 lb/MMBtu - 3 3.75 Ib/yr 0.00 tpy
CO 0.95 lb/MMBtu - 3 9.89 lb/ r 0.00
Acetaldehyde 7.67E-04 lb/MMBtu - 3 0.01 lb/ r 3.99E-06 tpy
Acrolein 9.25E-05 lb/MMBtu - 3 9.63E-04 lb/ r 4.82E-07 tpy
Benzene 9.33E-04 lb/MMBtu - 3 0.01 lb/ r 4.86E-06 tpy
Butadiene- 1,3 3.91E-05 lb/MMBtu - 3 4.07E-04 lb/yr 2.04E-07 tpy
Formaldehyde 1.18E-03 lb/MMBtu - 3 0.01 lb/yr 6.14E-06 tpy
Napthalene 8.48E-05 lb/MMBtu - 3 8.83E-04 lb/yr 4.41E-07 tpy
POM 8.32E-05 lb/MMBtu - 3 8.66E-04 lb/ r 4.33E-07
Toluene 4.09E-04 lb/MMBtu - 3 0.00 lb/ r 2.13E-06 t
Xylene 2.85E-04 lb/MMBtu - 3 0.00 lb/ r 1.48E-06
References:
1. Heat input for emergency generator calculated by:465 hp-out*2544.434 Btu-in/hp-hr.
2. Fuel consumption for emergency generator was calcultated by 1,183,161.81 Btu/hr*gal/141,000 Btu.
3. Emission factors obtained from AP-42, Section 3.3,Tables 3.3-1 and 3.3-2,October 1996. All PM is assumed to be
1 of 1 PB-I-ODG
PD and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Gasoline Tank
Equipment ID Number: I-GAS
Emission Point:
Control Device: N/A
2019 Actual Process Throughput:
Total VOC Emissions '= 10.70 lbs
0.01 tpy
Throughput= 7,991.0 gal/yr
Actual Hours of Operation=. 8,760.0 hr/yr
2019 Actual Emissions Summary:
on ro
Vapor Weight Efficiency
Compound 2 Percent M Reference Uncontrolled and Controlled Emissions
Benzene 3.25% - 3 0.35 lb/yr 1.74E-04 tpy
Chlorobenzene 0.03% - 3 3.21E-03 lb/yr 1.61E-06 tpy
Cumene 0.33% - 3 0.04 %.:lb/yr 1.77E-05 tpy
Ethyl benzene 4.07% - 3 0.44 lb/yr 2.18E-04 tpy
Hexane,n- 3.91% - 3 0.42 lb/yr 2.09E-04 tpy
Naphthalene 0.80% - 3 0.09 lb/yr 4.28E-05 tpy
Styrene 0.17% - 3 0.02 lb/yr 9.10E 06 tpy
Toluene 15.22% - 3 1.63 lb/yr 8.14E-04 tpy
Trimeth 1 pentane 0.68% - 3 0.07 lb/ r 3.64E-05 tpy
Xylenes 21.69% - 3 2.32 lb/yr 1.16E-03 tpy
References:
1. RVP-10 gasoline 500 gallon,outside, above-ground tank,painted white put into service mid-2003.
2. EPA SPECIATE database in AIRCHIEF, Oct. 1993.
3. Emissions estimated by EPA Tanks Program,V.4.09d.
1 of 1 PB-I-GAS
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Rock-Metal Separator
Equipment ID Number: 3501
Emission Point: -
Control Device: CD-SC,CD-3501 `
2019 Actual Process Throughput:
Process Material=green sawdust
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill I= 67,362 tpy
Test Process Rate 2'3= 17,440 lb/hr
Test PM Emissions 3= 1.10E-02 lb/hr
Test Formaldehyde Emissions3= 8.50E-03 lb/hr
2019 Actual Emissions Summary:
Control
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 1.26E-03 lb/ton - 2,4 85 lb/ r 0.04 tpy
PMio i 2.5 1.26E-03 lb/ton - 2,4 85 lb/yr 0.04 tpy
Revised VOC 0.449 lb/ton - 2,-3,5 30,247 lb/yr 15.12 tpy
..._ .� lb/yr
Formaldehyde 9.75E-04 lb/ton - 2 66 lb/ r 0.03 tpy 65.6628
Methanol 1.60E-02 lb/ton - 6 1,078 L r 0.54 y 1077.8
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.41.
2. Emission factor based on oven-dried(OD)process material rates.Amount of material processed through each unit bagfilter is
calculated based on%of total material processed by mill.
3. Values obtained from Weyco-Moncure emission tests in April 1994 and April 1995.
4. PM is assumed to equal PMio and PM2.5. Amount of material processed through each unit bagfilter is calculated based on%of
total material processed by mill.
5. WPP 1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane-0.65*acetone as propane.
6. NCASI TB 711,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 6.2.1,Summary of Particleboard Rotary Furnish Dryer Emissions(Pre-Dryer,Mill 039).
1 of 1 PB-3501
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Fines Transport
Equipment ID Number: 3515
Emission Point:
Control Device: CD-3500,CD-3525,CD-3512B,CD-3515 .
2019 Actual Process Throughput:
Process Material= dry sawdust
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill = 100,715 tpy
Test Process Rate 2'3= 53,059 lb/hr
Test PM Emissions 3= 8.91 E-03 lb/hr
Test Formaldehyde Emissions3= 3.00E-02 lb/hr
2019 Actual Emissions Summary:
--Control
Efficiency.
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 3.36E-04 lb/ton - 2,3 33.83 lb/ r 0.02 tpy
PM10/2.5 3.36E-04 lb/ton - 2,3 33.83 lb/yr 0.02 tpy
WPP1 VOC 1.18 lb/ton - 1 2,4 118,603.8 lb/yr 59.30 tpy
lb/yr
Formaldehyde 1.13E-03 lb/ton - 2 113.9 lb/ r 0.06 tpy 113.89
Methanol 1.60E-02 lb/ton - 5 1,611.4 lb/yr 0.81 tpy 1611.44
References:
I. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.613. -
2. Emission factor based on.oven-dried(OD)process material rates.Amount of material processed through each unit bagfilter is
calculated based on%of total material processed by mill.
3. PM is assumed to equal PM10 and PM2.5. Amount of material processed through each unit bagfilter is calculated based on%of total
4. WPP 1 VOC=VOC as propane+methanol+formaldehyde-O.65*methanol as propane-0.65*acetone as propane.
5. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 6.2.1,Summary of Particleboard Rotary Furnish Dryer Emissions(Pre-Dryer,Mill 039).
1 of 1 PB-3515
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Surface Formers,Mat Dumps,Wet Transport
Equipment 1D Number: 3525
Emission Point:
Control Device: CD-3520A,CD-3520B,CD-3521,CD-3525
2019 Actual Process Throughput:
Process Material= green wood
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill I= 5,422 tpy
Test Process Rate 2'3= 2,000 lb/hr
Test PM Emissions3= 6.00E-03 lb/hr
Test Formaldehyde Emissions = 4.70E-02 lb/hr
2019 Actual Emissions Summary:
--Control —
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 6.00E-03 lb/ton - 2,4 32.53 lb/ r 0.02 tpy
PM10i2.5 6.00E-03 lb/ton - 2,4 32.53 lb/yr 0.02 tpy
Revised VOC 0.307 lb/ton - 2,3,5 1,663.70 Ib/yr 0.83 tpy
lb/yr
Formaldehyde 4.70E-02 lb/ton - 2 254.83 lb/ r 1 0.13 tpy 254.827
Methanol 9.10E-03lb/ton - 6 49.34lb/yr 0.02 y 49.3388
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.033.
2. Emission factor based on oven-dried(OD)process material rates.Amount of material processed through each unit bagfilter is
calculated based on%of total material'processed by mill.
3. Values obtained from Weyco-Moncure emission tests in April 1994 and April 1995.
4. PM is assumed to equal PMIO and PM2.5. Amount of material processed through each unit bagfilter is calculated based on%of
total material processed by mill.
5. WPP 1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
6. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 5.1.3,Rotary Face Dryer Emissions,Mill 010.
1 of 1 PB-3525
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment:Dry Material Transport
Equipment 1D Number: 3535
Emission Point:
Control Device: CD-3530,CD-3531,CD-3533,CD-3535
2019 Actual Process Throughput:
Process Material=dry wood waste
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mi111= 14,458 tpy
Test Process Rate2,3= 7,798 lb/hr
Test PM Emissions3= 8.10E-03 lb/hr
Test Formaldehyde Emissions3= 8.61E-02 lb/hr
2019 Actual Emissions Summary:
on ro -
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions.
PM 2.08E-03lb/ton - 2,3 30 lb/yr 0.02 tpy
PM10/2_5 2.08E-03 lb/ton - 2,3 30 lb/yr 0.02 tpy
WPP1 VOC 1.081 lb/ton - 2,4 12,811 lb/ r 6.41 tpX
_ lb/yr
Formaldehyde 2.21 E702 lb/ton - 2 319 lb/yr 0.16 tpy 319.2755
Methanol 9.10E-03 lb/ton - 5 132 1!/ r 0.07 131.57
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.613.
2. Emission factor based on oven-dried(OD)process material rates.Amount of material processed through each unit bagfilter is
calculated based on%of total material processed by mill.
3. PM is assumed to equal PM10 and PM2.5. Amount of material processed through each unit bagfilter is calculated based on%of
total material processed by mill.
4. WPP1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
5. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 5.1.3,Rotary Face Dryer Emissions,Mill 010.
1 of 1 PB-3535
PB and MDF,Moncure,NC
Permit Number 03449`I'51
Emission Unit Equipment:Steinemann Sander
Equipment ID Number: 3545
Emission Point:
Control Device: CD-2006,CD-3570,CD-3575
2019 Actual Process Throughput:
Process Material=dry sanderdust
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill = 21,852 tpy
Test Process Rate Z'3= 8,298 lb/hr
Test PM Emissions 3= 8.30E-03 lb/hr
Test Formaldehyde Emissions3= .1.58E-01 lb/hr
2019 Actual Emissions Summary:
Control
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 2.00E-031b/ton - 2,4 44 lb/yr 0.02 tpy
PM1012.i 2.00E-03 lb/ton - 2,4 44 lb/yr 0.02 tpy
WPP1 VOC 0.273 lb/ton - 2,3,5 5,955 Ib/yr 2.98 tpy
lb/yr
Formaldehyde 3.81 E-02 lb/ton - 2 832 lb/yr 0.42 tpy 832.1436
Methanol 9.10E-03 lb/ton - 6 199 lb/jr 0.10. 198.8502
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.133.
2. Emission factor based on oven-dried(OD)process material rates.Amount of material processed through each unit bagfilter is
calculated based on%of total material processed by mill.
3. Values obtained from Weyco-Moncure emission tests in April 1994 and April 1995.
4. PM is assumed to equal PMIO and PM2.5. Amount of material processed through each unit bagfilter is calculated based on%of
total material processed by mill.
5. WPP1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
6. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 5.1.3,Rotary Face Dryer Emissions,Mill 010.
1 of 1 PB-3545
J
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: PB Sanderdust Transport
Equipment ID Number: 3565
Emission Point:
Control Device: CD-5001,CD-3570,CD-3575
2019 Actual Process Throughput: _
Process Material=dry Sanderdust
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill'= 6,572 tpy
Test Process Rate2'3= 2,070 lb/hr
Test PM Emissions3= 6.20E-01 lb/hr
Test Formaldehyde Emissions= 4.31 E-02 lb/hr
2019 Actual Emissions Summary:
on ro
Efficiency
Compound Emission Factor (%) Refer6nce Uncontrolled and Controlled Emissions
PM 5.99E-01 lb/ton - 2,3 3,937 lb/ r 1.97 tpy
PM10i2.5 5.99E-01 lb/ton - 2,3 3,937 lb/yr 1.97 tpy
WPP1 VOC 1 0.353 lb/ton - 1 2,4 1 2,320 lb/yr 1.16 tpy
lb/yr
Formaldehyde 4.16E-021b/ton - 2 274 lb/ r 0.14 tpy 273.6717
Methanol 9.10E-03lb/ton - 5. 60 lb/ 0.03 59.80457
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.04.
2. Emission factor based on oven-dried(OD)process material rates.Amount of material processed through each unit bagfilter is
calculated based on%of total material processed by mill.
3. PM is assumed to equal PM O and PM,.5. Amount of material processed through each unit bagfilter is calculated based on%of
4. WPP1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
5. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 5.1.3,Rotary Face Dryer Emissions,Mill 010..
1 of 1 PB-3565
PB and M DF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Board Trim Transfer
Equipment ID Number: 3555 .
Emission Point:
Control Device: CID-3522,CD4005
2019 Actual Process Throughput:
Process Material= dry sawdust
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill'= 35,817 tpy
Test Process Rate2'3= 12,762 lb/hr
Test PM Emissions 3= 4.51E-03 lb/hr
Test Formaldehyde Emissions3= 1.30E-02 lb/hr
2019 Actual Emissions Summary:
Control
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 7.07E-04lb/ton - 2,3 25 Ib/ r 0.01 tpy
PM10i2.5 7.07E-041b/ton - 2,3 25 lb/yr 0.01 tpy
WPP1 VOC 0.140lb/ton - 2,4 5,016 lb/yr 2.51 tpy
Ilb/yr
Formaldehyde 2.04E-03 lb/ton - 2 73 lb/ r 0.04 tpy 72.96995
Methanol 9.10E-03 lb/ton - 5 326 lb/ r 0.16 325.9349
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.613.
2. Emission factor based on oven-dried(OD)process material rates.Amount of material processed through each unit bagfilter is
calculated based on%of total material processed by mill.
3. PM is assumed to equal PM()and PM2.5. Amount of material processed through each unit bagfilter is calculated based on%of total
material processed by mill.
4. WPP1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
5. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 5.1.3,Rotary Face Dryer Emissions,Mill 010.
1 of 1 PB-3555
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Sanderdust Silo
Equipment ID Number: 3575
Emission Point:
Control Device: CD-3570,CD-3575
2019 Actual Process Throughput:
Process Material=dry sanderdust
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill = 8,872 tpy
2019 Actual Emissions Summary:
on ro
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 0.400 lb/ton 80,99.9% 2 3,549 lb/yr 1.77 tpy
PM10i2.5 0.400 lb/ton 80,99.9% 2 3,549 lb/yr 1.77 tpy
WPP1 VOC 0.353 lb/ton - 3 3-,136 lb/yr 1.57 tpy
lb/yr
Formaldehyde 4.20E-02 lb/ton - 4 373 lb/yr 0.19 tpy 372.628
Methanol 9.10E-03 lb/ton - 5 81 lb!/ r 0.04 80.7362
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.054.
2. No test was conducted. Emission factor based on control equipment manufacturer efficiency guarantee for cyclone at 80%plus
fabric filter at 99.9%.
3. WPP1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
4. No test was conducted. Emission factor based on engineering judgement for a similiar source(3565).
5. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
1 of 1 PB-3575
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Flakers
Equipment ID Number: 3585
Emission Point:
Control Device: CD-3585
2019 Actual Process Throughput:
Process Material= dry flakes
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill = 96,936 tpy
2019 Actual Emissions Summary:
on ro
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 0.20 lb/ton 99.99% 2 19,387 lb/ r 9.69 tpy
PM10/2.5 0.20 lb/ton 99.99% 2 19,387 lb/yr 9.69 tpy
WPP1 VOC 0.18 lb/ton - 3 1 17,028 lb/yr 8.51 tpy
Ib/yr
Formaldehyde 1.37E-03lb/ton - 5 133 lb/yr 0.07 tpy 132.802
Methanol 9.10E-03lb/ton - 6 882 lb/yr 0.44 882.117
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.59.
2. No test was conducted. Emission factor based on control equipment manufacturer efficiency guarantee for fabric filter at 99.99%.
3. WPP1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
4. No test was conducted. Emission factor based on engineering judgement for a similiar source.
5. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(O1/1999),Table 5.2.1,Combined Flaker Emissions,Mill 039.
1 of 1 PB-3585
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Dry Material Transport
Equipment ID Number: 3577
Emission Point:
Control Device: CD-3532,CD-3577
2019 Actual Process Throughput:
Process Material=dry wood waste
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill = 49,947 tpy
2019 Actual Emissions Summary:
on ro
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 2.08E-03 lb/ton - 2 104 Ib/yr 0.05 tpy
PM10/2.; 2.08E-03 lb/ton - 2 104 lb/yr 0.05 tpy
WPP1 VOC 1.084 lb/ton - 3 54,122 Ib/yr 27.06 tpy
lb/yr
Formaldehyde 0.022 lb/ton - 2 1,099 lb/ r 0.55 tpy 1098.83
Methanol 1.60E-02 lb/ton - 4 799 Ib/ r 0.40 799.147
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.304.
2. No test was conducted. Emission factor based on engineering judgement for a similiar source(3535).
3. WPP1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
4. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 6.2.1,Summary of Particleboard Rotary Furnish Dryer Emissions(Pre-Dryer,Mill 039).
1 of 1 PB-3577
1
PB and MDF,Moncure,NC _
Permit Number 03449T51
Emission Unit Equipment: Dry Material Transport
Equipment ID Number: 3577
Emission Point:
Control Device: CD-3532,CD-3577
2019 Actual Process Throughput:
Process Material=dry wood waste
Operating Hours= 6,097 br/yr
Wood Processed by Mill=- 164,298 BDT/yr
Wood Processed by Mill = 49,947 tpy
2019 Actual Emissions Summary:
on ro
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 2.08E-03 lb/ton - 2 104 lb/yr 0.05 tpy
PM1012.5 2.08E-03 lb/ton - 2 104 lb/yr 0.05 tpy
WPP1 VOC 1.084 lb/ton 3 54,122 lb/yr 27.06 tpy
_ lb/yr
Formaldehyde 0.022 lb/ton - 2 1,099 lb/yr 0.55 t 1098.83
Methanol 1.60E-02 lb/ton - 4 799 lb/ r 0.40 t 799.147
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.304.
2. No test was conducted. Emission factor based on engineering judgement for a similiar source(3535).
3. WPPI VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
4. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 6.2.1,Summary of Particleboard Rotary Furnish Dryer Emissions(Pre-Dryer,Mill 039).
1 of 1 PB-3577
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Fines Transport
Equipment ID Number: . 3595
Emission Point:
Control Device: CD-3595
2019 Actual Process Throughput:
Process Material= dry sawdust
Operating Hours= 6,097 hr/yr
Wood Processed by Mill= 164,298 BDT/yr
Wood Processed by Mill = 6,572 tpy
2019 Actual Emissions Summary:
on ro
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 2.04E-03lb/ton - 2 13 lb/yr 6.69E-03 tpy
PM10/2.5 2.04E-03 lb/ton - 2 13 lb/yr 6.69E-03 tpy
WPPI VOC 0.18 lb7ton. - 3 1,175 lb/yr 0.59 tpy
lb/yr
Formaldehyde 2.04E-03 lb/ton - 2 13 lb/ r 6.69E-03 tpy 13.39
Methanol 1.60E-021b/ton - 4 105 lb/yr 5.26E-02 tDv 105.15
References:
1. Quantity of wood processed by mill was converted to tons per year by being multiplied by 0.04.
2. No test was conducted. Emission factor based on engineering judgement for a similiar source(3555).
3. WPP1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol as propane.
4. NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV—Particleboard
(01/1999),Table 6.2.1,Summary of Particleboard Rotary Furnish Dryer Emissions(Pre-Dryer,Mill 039).
z
-J
1 of 1 PB-3595
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Short Cycle Laminating Presses
Equipment ID Number: 3593 &3594(Two Identical Units)
Emission Point:
Control Device: CD-3593
2019 Actual Process Throughput:
Wemhoner Steinemann -
Short Cycle Short Cycle.
Laminating Laminating
Press [3593] Press [3594]
Annual Operating Hours= 0 0 hr/yr
Production= 0 0 MSF Board Feet/yr
2019 Actual Emissions Summary: -
control
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM 0.86lb/hr - 1 0.000lb/yr 0.000 tpy
PM10 0.55 lb/hr - 1 0.000 lb/yr 0.000 tpy
PM,5 10.31 lb/hr - 1 0.000 lb/yr 0.000 tpy
WPP1 VOC 0.036 lb/hr - 1,2 0.000 lb/jr 0.000 1EX
r, lb/yr
Formaldeh de 0.02 lb/hr - 1 0.000 lb/ r =000 tpy 0
References:
1 Emission factors from a similar source were used. The similar press is 9MM in/yr,whereas Uniboard's press has
a design of approximately 17.6 MM in/yr,therefore, emission factors from similar source are multiplied by
2. WPP1 VOC=VOC as propane+methanol+formaldehyde.
1 of 1 PB-3593&3594
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Ponds 2-5 and Evaporator
Equipment ID Number: I-Wastewater ponds
Emission Point:
Control Device: N/A
2019 Actual Process Throughput:
Spray and Pond Concentration= 0.2 mg/L
1.67E-06 lb/gal
Pond Capacity= 2,879,000 gal/yr
2019 Actual Emissions Summary:
Control
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
Ponds 2-5
VOC 1.67E-06 lb/gal 1 4.81 lb/ r 2.40E-03 tpy
Formaldeh de 1.67E-06 lb/gal 1 4.81 Ib/yr 2.40E-03 tpy
References:
1. Concentration from 2011 Formaldehyde test.Using half of detection limit since concentration was below the detection limit of r
0.4 mg/L.
r
1 of 1 PB-Ponds
FORMALDEHYDE
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Formaldehyde was produced as a byproduct during drying,blending,forming,pressing,and fuel combustion.
Category Throughput Production Factor Formaldehyde
Manufactured
PB Fire Pump and Backup Generator 87 MMBtu r 1.18E-03 Ib/MMBtu 1 0.10
PB Thermal Oil.Heater 0.64 MMscf r 7.50E-02 Ib/MMscf 2 0.05
PB Laminating Press 0 hrs/ r 2.00E-02 Ib hr 8 0
PB RK MT Separator 67,362 ton/r 9.75E-04 lb/ton 15 66
PB Dryers(all NG) 6,097 hrs/r 2.24E+00 Ib/hr 11 13,657
1.6 MMscf r 7.50E-02 Ib MMscf 2 0
PB Wellons Bypass-Wood 0 MMBtu r 8.83E-04 Ib MMBtu 13 0
PBWellons Bypass-Gas 14 MMscf/r 7,50E-02Ib MMscf 2 1
PB Fines System 100,715 ton/r 1.13E-03 lb/ton 9 114
PB Wet Mat'I System 5,422 ton r 4.70E-02 lb/ton 9 255
PB Dryer Mat'I System 14,458 ton/r 2.21E-02 lb/ton 9 319
PB Steinemann Sander 21,852 ton r 3.81E-02 lb/ton 9 832
PB SanderdustSystem 6,572 ton/r 4.16E-02 lb/ton 9 274
PB Board Trim Transfer 35,817 ton r 2.04E-03 lb/ton 9 73
PB Press 6,097 hr r 1.59E+00 Ib hr 11 9,694
PB Board Cooler 138,792 MSF/ r 2.70E-02 Ib MSF 12 3,747
PB Sanderdust Silo 8,872 ton/ r 4.20E-02 lb/ton 10 373
PB Flakers 96,936 ton/r 1.37E-03 Ib/ton 15 133
PB Fines Transport 6,572 ton/ r 2.04E-03 lb/ton 10 13
PB Dry Waste System 49,947 tan r 2.20E-02 lb/ton 9 1,099
MDF Natural Gas comb in backup TOH .
216.9 MMscf r 7.50E-02 Ib MMscf 2 16
MDF Emergency Generator 22,288 h -hr r 5.52E-07 Ib h -hr 16 0.0
MDF Dryer Exhaust Biofilter 239,750 ODMT/ r 4.36E-02 Ib ODMT 4 10,462
MDF Press O.00E+00 Ib MSF 4 0
MDF Fiber sifters stem filter 239,750 ODT/r 8.90E-03 Ib ODT 6 2,134
MDF Forming Line Clean-Up Filter 239,750 ODT/r 8.90E-03 Ib ODT 6 2,134
MDF Mat rejects stem Filter 13,809 ODT/r 8.90E-03 Ib ODT 6 123
MDF Saw System Filter 5,670 ODT/r 1.80E-02 Ib/ODT 6 102
MDF Sander System No.1 Exhaust Filter 151449 MSF/r 4.00E-04 Ib/MSF 6 61
MDF Recycled Fiber Silo No.1 Filter 12,606 ODT/r 8.90E-03 Ib ODT 6 112
MDF Sander System No.2 Exhaust Filter 151449 MSF r 4.00E-04 Ib/MSF 6 61
MDF Sander Dust Silo No.1 Filter 8,391 ODT/r 4.00E-04 Ib/ODT 6 3
MDF Dry Sawdust Silo Filter 11,988 ODT r 0.00E+00 Ib ODT 6 0
MDF Recycled Fiber Silo No.2 Filter 12,606 ODT/ r 8.90E-03 Ib ODT 6 112
MDF Sander Dust Silo No.2 Filter 8,391 ODT/ r 4.00E-04 Ib ODT 6 3
MDF Resin Tanks-Fugitive 3#tanks 1.00E-03lb/hr/tank (7) 26
Total Manufactured 46,000
Manufacturing Threshold 25,000
Reporting Required? Yes
Notes:
1.Emission Factor from AP-42,Table 3.3-1 and 3.3-2,October 1996
2.AP-42 Section 1.4.July 1998
3.Emission factors from NCASI TB 770,Table 6.4.2,Mill 142 No.1 Board Cooler,January 1999
4.Source Testing Conducted at the Moncure mill. VOC test data form May 31,2018 testing. Formaldehyde and methanol data from Jun(
S.Emission Factor based on NCASI TB 770,Table 6.3.1 Mill 404,January 1999
6. NCASI Technical Bulletin 770,Mill 132 emission factors,January 1999.
7.Emission Factor based on PCWP Rule Table 2A
8.Emissions estimates from a similar source
9. Weyco-Moncure emission tests in April 1994 and April 1995
10. Emission factor based on engineering judgement for a similar source.
11.VOC is WPP1 VOC=VOC as propane+methanol+formaldehyde-0.65*methanol.Methanol and formaldehyde values from July 201E
12.Emission factors obtained from NCASI SARA 313 Guidance Updated 2011-Median Values.
13.Emission Factors from NCASI TB 973,Table 7.1-Uncontrolled,February 2010
14.Emission factors from NC DAQ's fuel oil spreadsheet-based on AP-42,5th edition,Section 1.3.
15.NCASI TB 771,Volatile Organic Compound Emissions from Wood Products Manufacturing Facilities,Part IV-Particleboard(01/1999),
16.Emission factors from NC DAQ's diesel engine spreadsheet.
Processed
Formaldehyde was not processed at this facility in concentrations greater than 0.1%.
Otherwise Used
Formaldehyde was not otherwise used at this facility.
C:10aenrMlmeNeMppDmoLLoceMScroaortlWlMam\WeICncM1nlContoM.OWooMHOWB9WUE11010 Wo AEI TRI B-1 7/20/2020
LEAD AND LEAD COMPOUNDS
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Lead(Pb)compounds were produced as a byproduct during fuel combustion.
Category Throughput Concentration Conversion Ratio Leaa LOmpounds
lb Plpmpnt) Manufactured
MDF and PB Natural Gas Combustion 232.96 MMscf/yr 3.12E+00 Ib/109 W gas (1) 1.08 lb PbO/lb Pb 0.78 lb PbC/yr
MDF Hog Fuel Combustion in Teaford: 50,218,276 Ib r 5.17E-06 lb Pb/lb(dry) 1 1.08 lb PbO/lb Pb 140.20 lb Pb0/ r
MDF Sanderdust Combustion in Teaford: 9,565,386 Ib r 6.23E-07 I Pb/lb(dry) 1 1.08 lb Pb0/lb Pb 5.985 lb Pb0/ r
PB Diesel Use 632 al r 3.20E-08 lb Pb al 1 1.08 lb PbO/lb Pb 0.000 lb Pb0/ r
PB Hog Fuel Combustion in Wellons: 0 Ib r 5.17E-06 lb Pb/lb(dry) 1 1.08 lb PbO/lb Pb 0.00 lb Pb0/ r
PB Sanderdust Combustion in dryers: 76 735 698 Ib r 6.23E-07 Ib Pb Ib d 1 1.08 lb PbO/lb Pb 48.017 lb Pb0/ r
PB Wellons Bypass 011blyr 6.23E-07 Ib Pb/lb d (1) 1,08 Ib PbO/lb Pb 0.000 Ib PbO/yr
Total Manufactured 195.0 Ib r
Manufacturing Threshold 100 Ib/ r
Reporting Required? Yes
Notes:
1. Mean Pb concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting
' - 1
Processed
Lead present in wood was processed to make PB and MDF.
Product Name Product Lead Corn ounds
Usage Content Usage
(Ib/yr)
MDF Press Production 264,279 ODT/ r 6.23E-07 Ib Pb/lb wood 1 659 Ib/ r
PB Press Production 179,311 ODT/yr 6.23E-07 Ib Pb/lb wood (1) 447 Ib/yr
Total Processed 1,105 Ib/ r
Processed Threshold 100.0 Ib/ r
Reporting Required? Yes
Notes:
1. Mean Pb concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2017,last updated March 2010.
Otherwise Used
Lead was otherwise used as a trace element in fuels.
Category Product Usage Concentration Lead Usage
MDF and PB Natural Gas Combustion 233 MMscf/yr 5.00E-02 Ib 109 ft3 as 11 0.73 lb Pb/ r
MDF Hog Fuel Combustion in Teaford: 50,218,276 Ib r 5.17E-06 lb Pb/lb(dry) 1 129.81 lb Pb/ r
MDF Sanderdust Combustion in Teaford: 9,565,386 Ib r 6.23E-07 lb Pb/lb(dry) 1 5.54 lb Pb/ r
PB Diesel Use 632 al r 3.20E-08 lb Pb al 1 0.000 lb Pb/ r
PB Hog Fuel Combustion in Wellons: 0 Ib r 5.17E-06 lb Pb/lb d 1 0.00 lb Pb/ r
PB Sanderdust Combustion in dryers: 76,735,698 lb r 6.23E-07 Ib Pb/lb d 1 44.46 lb Pb/ r
PB Wellons B ass 0 Ib r 6.23E-07 Ib Pb/lb d (1) 0.00 Ib Pb/yr
Total Otherwise Used 180.5
Otherwise Used Threshold 106
Reporting Required? Yes
Notes:
1. Mean Pb concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2017,last updated March 2010.
C:WsenMlmnFlol4ppDalaLLxoMlicrosoMW vWonslWotCacM1olConlenLOUYcakW 0W 09W UE12010 Moncure AEI TRI Calcs 2020-00171,od CompowJ-1 7/20/2020
METHANOL
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufacturing
Methanol was produced as a byproduct during drying,blending,forming,pressing,and wood combustion.
Category Throughput Production Factor Methanol
Manufactured
(lb/yr)
MDF Dryer&Press Exhaust(Biofilter) 239,750 ODMT r 2.11E+00 Ib/CDMT 1 506,733.
MDF Fiber sifters stem filter 239,750 CDT r 6.90E-03 Ib/CDT S 1654'
MDF Forming Line Clean-Up Filter 239,750 ODT/r 6.90E-03 Ib/ODT 5 1654
Mat rejects stem.Filter 239,750 CDT/r 6.90E-03 Ib/ODT 5 1654
MDF Saw System Filter 5,670 ODT/r 2.50E-01 lb/CDT 5 1418
MDF Sander System No.1 Exhaust Filter 151449 MSF/r 1.80E-03 Ib MSF 5 273
MDF Recycled Fiber Silo No.1 Filter 12,606 ODT r 6.90E-03 Ib/ODT 5 87
MDF Sander System No.2 Exhaust Filter 151449 MSF r 1.80E-03 Ib/MSF 5 273
MDF Sander Dust Silo No.1 Filter 8,391 ODT r 1.80E-03 Ib/ODT 5 15
MDF Dry Sawdust Silo Filter 11988 ODT r 1.80E-03 Ib/ODT 5 22
MDF Rec cled
Fiber Silo No.2 Filter 12,606 ODT r 6.90E-03 lb/CDT 5 87
MDF Sander Dust Silo No.2 Filter 8,391 CDT r 1.80E-03 lb/CDT 5 15
PB Dryers 6,097 hr r 3.17E+00 Ib hr 6 19,327
PB Press 6,097 hr/r 4.20E+00 Ib/hr 6 25,607
PB Board Cooler 138,792 MSF/yr 5.40E-02 Ib/MSF (7) .7,495
Total Manufactured 558,819
Manufacturing Threshold 25,000
Reporting Required? Yes
Notes:
1.Source Testing Conducted at the Moncure mill. VOC test data form May 31,2018 testing. Formaldehyde and methanol dat
2.Emission factors from NCASI TB 770,Table 6.4.2,Mill 142 No.1 Board Cooler
3.Emission factors per NCASI TB770,Table 6.1.2 Mill 132 average.January 1999
4.Emission Factor based on NCASI TB 770,Table 6.3.1 Mill 404,January 1999
Technical
Bulletin
770,
Volatile
Organic
Compound
Emissions
from
Wood
Products
Manufactu
ring
Facilities,
Part III—
Medium
Density
Fiberboard
(01/1999),
Table
5.2.4, n
Miscellane
ous
Source
Emissions,
Mill 132
(Saw
Reclaim
6.Emission factors from Stack testing 12/2005
7.AP-42 Wood Products Industry-Particleboard Manufacturing,10.6.2 June 2002.
Processed
Methanol was not processed at tHis facility in concentrations greater than 1%.Resin storage,and blending and forming
emissions are due to resin evaporation and are not counted in the manufacturing thresholds.
Otherwise Used
Methanol was not otherwise used at this facility.
C{UsenMhmWeMppDateLLacohNrromR�W'vdm nVNelCecha\CaNem.ONloakWOW00WIlElt018 Wo AE1—Cats RJ IN 1e 1 B-1 712012D20
ACETALDEHYDE
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
i
Manufactured
Acetaldehyde was produced as a byproduct during drying,pressing,and fuel combustion.
Category Throughput Production Factor Acetaldehyde
Manufactured
MDF Backup Generator 22,288 hp-hr/yr 1.76E-07 Ib/hp-hr (1) 0.00
MDF Dryer Outfeed Scrubbers 151,449 MSF 3/4"/yr 7.90E-03 lb/MSF (2) 1,196
239,750 ODMT/yr 1.93E-02 Ib/ODT (4) 5,099
MDF Teaford Abort 32,720 MMBtu/ r 1.22E-04 Ib/MMBtu (3) 4
PB Fire Pump and Backup Generator 87 MMBtu/ r 7.67E-04 Ib/MMBtu (1) 0.07
PB Dryers 6,097. hr/yr 1.06E+00 Ib/hr (5) 6,463
PB Wellons Bypass 0 MMBtu/yr 1.22E-04 Ib/MMBtu (3) 0.0
PB Press 6,097 hr/yr 1.04E-01 Ib/hr (5) 634
PB Board Cooler 138,792 MSF 3/4"/yr 1.30E-03 lb/MSF (2) 180
Total Manufactured 13,577
Manufacturing Threshold 25,000
Reporting Required? I No
1
Notes:
1. > mission factors obtained from NC DAQ spreadsheet for calculation of air emissions from internal combustion
2. NCASI SARA 313 Guidance for Wood Products Facilities,updated March'2011.
3. Emission factors from NCASI TB 973,Table 7.1 Uncontrolled,February 2010.
4. Emission factors per NCASI T13770,Table 6.1.2'Mill 132 average. January 1999.
5. Emission factors from PB Dryer RTO inlet stack testing 12/2005.
Processed
Acetaldehyde was not incorporated into the final product,therefore it was not processed at this site.
Otherwise Used
Acetaldehyde was not otherwise used on the plant site in concentrations greater than 0.1%.
C:\Users\mlmahlerWppData\Loc ftMicrosofilWindows\INetCache\Content.ONIooMHDW69WUE12019 Moncure ASEiRl dalcs_2020-031Mcetaldehyde 7/20/2020
ACROLEIN
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Acrolein was produced as a byproduct during drying,pressing,and fuel combustion.
Category Throughput Production Factor Acrolein
Manufactured
MDF Backup Generator 22,288 hp-hr/ r 5.52E-08 Ib/hp-hr (1) 1.23E-03
MDF Dryer Outfeed Scrubbers 151,449 MSF 3/4"/ r 7.30E-04 lb/MSF (2) 111
MDF Teaford Abort 32,720 MMBtu/yr 1.84E-06 Ib/MMBtu (3) 6.02E-02
PB Fire Pump and Backup Generator 40 MMBtu/ r 9.25E-05 Ib/MMBtu (1) 0.004
PB Dryers 6,097 hr/yr 3.25E-01 Ib/hr• (4) 1,982
PB Wellons Bypass 0 MMBtu/yr 3.16E-05 Ib/MMBtu (3) 0.0
PB Press 6,097 hr/ r.. 2.30E-02 lb/MSF (4) 140
PB Board Cooler 138,792 MSF 3/4"/yr 3.60E-04 lb/MSF (2) 50
L
Total Manufactured 2,282
anufacturing Threshold' 25,000
Reporting Required? No
Notes:
1. Emission factors obtained from NC DAQ spreadsheet for calculation of air emissions from internal combustion engines
2. NCASI SARA 313 Guidance for Wood Products Facilities,updated March 2011.
3. Emission factors from NCASI TB 973,Table 7.1 Uncontrolled,February 2010.
4. Emission factors from PB Dryer RTO inlet stack testing 12/2005.
Processed
Acrolein was not incorporated into the final product,therefore it was not processed.
Otherwise Used
Acrolein was not otherwise used on the plant site in concentrations greater than 1.0%.
r
C:\Users\mlmahlerlAppData\LocaMAcmwft\WindowsUNetCeche%Contenl.OullooWDW69WUE\2019 Moncure AEI TRI(RIM112020-031TAcrolein 7120/2020
AMMONIA
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Ammonia is manufactured by pressing operations with urea-formaldehyde resins. Following NCASI guidance:
Category Throughput Production Factor Ammonia Manufactured
HbLvrl
Press 443,590 ODT/yr 2.80E+00 mg/kg wood (1) 2,484
Total Manufactured 2,484
Manufacturing Threshold 25,000
Reporting Required? No
1.NCASI Chemical Specific Information for SARA Section 313 Form R issued 2017,last updated March 2010.
Processed
Ammonia was not incorporated into the final product,therefore it was not processed.
Otherwise Used
Ammonia was not otherwise used on the plant site in concentrations greater than 1.0%.
C:\Users\mlmahler\AppDato\LocaMAicrosofl\WindowsUNetCache\Conlent.OuVook\HDW69WUE\2019 Moncure AEI TRI(RICs12020-0317Wmmonia 7/20/2020
BARIUM COMPOUNDS
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Barium(Ba)compounds are manufactured as a byproduct of the combustion of wood.
(lb compound/lb Barium Compound
Category Throughput Concentration element) Manufactured
MDF Hog Fuel Combusted in Teaford 123,384,36 Ib/ r 7.10E-05 Ib Ba/lb 1 1.12 lb BaO/lb Ba 9812 lb Ba0/ r
MDF Sanderdust Combustion in Teaford 9,565,386 Ib/ r 1.01E-05 lb Ba/lb 2 1.12 lb BaO/Ib Ba 108 lb BaO/ r
Hog Fuel Combusted in Wellons 0 lb/ r 7.10E-05 Ib Ba/lb 1 1.12 lb BaO/lb Ba 0 lb Ba0/ r
PB Sanderdust Combustion in dryers 76,735,698 Ib/yr 1:01E-05 lb Ba/lb (2) 1.12 lb BaC/lb Ba 864 lb Ba0/ r
MDF backup TOH burners 232.96 mmsc yr 4.40E-03 lb Ba mmscf (3) 1.12 lb Ba0 Ib Ba 1 lb BaO/yr
Total Manufactured 10,784 Ib/ r
Manufacturing Threshold 25,000 Ib/ r.
Reporting Required? No
Notes:
1. Mean Ba concentrations in bark from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated March 2014.Table 2
2. Mean Ba concentrations in stem wood from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated March 2014.Tablt
3. Ba emission factor from natural gas from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated March 2014.Table 5
Processed
Barium compounds were not processed at this site.
Otherwise Used
Barium compounds were not otherwise used at this site.
t
C:lUsersMlmahlerWppDaWlLxullMicrowfhWind—.sINatCech.\CantenLO.U.kWDW69WUE12019 Mon....AEI TRI Cd.s 2020-031T a compounds 7/20/2020
BENZO(g,h,i)PERYLENE
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Benzo(g,h,i)perylene(BP)was produced as a byproduct during fuel combustion.
enzo g, ,i pert'ene
Category Throughput Production Factor Manufactured
MDF-Wood Combustion in Teaford 71,417 ODT/yr 1.50E-07 Ib/ODT (1) 1.07E-02 Ib/ r
PB-Wood Combustion in Wellons 0 ODT/yr 1.50E-07 Ib/ODT (1 0.00E+00 Ib/ r
Wood Combustion Fly Ash 3,112,488 lb ash/yr 1.80E-08 lb/lb ash (2) 5.60E-02 Ib/ r
Wood Combustion Bottom Ash 2,074,992 lb ash/yr 1.50E-07 lb/lb ash (2) 3.11E-01 Ib/ r
Diesel Fuel Combustion(engines)' 1,762 gal/yr 2.26E-06 Ib/103 gal 1) 3.98E-06 Ib/ r
Natural Gas Combustion 233 MMcf 1.20E-06 Ib%MMcf (1) 2.80E-04 Ib/yr
Total Manufactured 0.4 Ib/yr
Manufacturing Threshold 10 Ib/yr
Reporting Required? No
Notes:
1. Mean BP emission factor from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated Marc
2. Mean BP emission factor from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated Marc
Wood ash includes bottom ash and fly ash. Total ash was estimated as 40%bottom ash and 60%fly ash as provided in the NCASI chemical sp(
for dioxin and dioxin-like compounds.
Processed
Benzo(g,h,i)perylene was not processed at this facility.
Otherwise Used
Trace quantities of Benzo(g,h,i)perylene have been listed as being present in No.2 fuel oil.
Product Name Product Benzo(g,h,i)perylene
Usages Content Usage
(Ib/yr) (ppm) (lb/yr)
No.2 Fuel Oil 12,424 0.05 0.001
Total Otherwise Used 0.0
Otherwise Used Threshold 10
Reporting Required? No
Notes:
1. No.2 fuel oil typical density of 7.05 lb/gal(AP-42).
2. Median BP concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting for
Panel Plants,last updated February 2006.
C:lUsemlmlmahler%AppDatalLomWicmwftlWindows\INetCachelContent.OutlmklHDW69W UE12010 Moncure AEIBRI C10Ics-2020-03170enmperylene 7/20/2020
DIISOCYANATE COMPOUNDS
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE, NORTH CAROLINA
2019
Manufactured
Diisocyanate compounds were not manufactured at this facility.
Processed
Diisocyanate was not processed at this facility.
Otherwise Used
Diisocyanate compounds were not otherwise used at this facility.
C:\Users\mlmahlerWppData\LocaRMicrosoft\Windows\INetCache\Conlent.Outl00k\HDW69WUE\2019 Menel BAENRI Calcs_2020-03170isocyanate 7/20/2020
DIOXIN AND DIOXIN-LIKE COMPOUNDS
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019.
i
Manufactured
Dioxin and dioxin-like compounds(PCDD/F)were produced as a byproduct during fuel combustion.
Category Throughput Concentration
Manufactured
MDF-Wood Combustion in Teaford 68,260 ODT r 5.01E-07 ODT (1) 0.0342 g/yr
PB-Wood Combustion in Wellons 0 ODT r 5.01E-07 ODT (1) 0.0000 g/yr
Wood Combustion Fly Ash 3,112,488 lb ash r 4.60E-11 g/g ash (2) 0.0649 g/yr
Wood Combustion Bottom Ash 2,074,992 lb ash r 2.09E-12 g/g ash (2) 0.0020 g/yr
No. 2 Fuel Oil Combustion 1,7621gallyr 1.20E-08 al oil (3) 0.0 g/yr
Total Manufactured 0.1011 g/yr
Manufacturing Threshold 0.1000 g/yr
Reporting Required? Yes
Notes:
1. PCDD/F concentrations calculated using the sum of the median CDD/F isomer concentrations from NCASI Chemical Specific Informatic
2019,last updated March 2014.Table 2.
2. PCDD/F concentrations calculated using the sum of the median CDD/F isomer concentrations from NCASI Chemical Specific Informatic
2019,last updated March 2014.Table 5.Wood ash includes bottom ash and fly ash. Total ash was estimated as 40%bottom ash and 60�
sheet for dioxin and dioxin-like compounds.
3. PCDD/F concentrations for fuel oil calculated using the sum of the median CDD/F isomer concentrations from NCASI Chemical Specific
issued 2019,last updated March 2014.Table 6.
Processed
Dioxin and dioxin-like compounds were not processed at this facility.
Otherwise Used
Dioxin and dioxin-like compounds were not otherwise used at this facility.
C:\Users\mlmahleAAppData\LocaRMiewsoft\WindowsllNetCache\Content.OutlooklHDW69WUE12019 Moncu,5AENRI Calcs-2020-031701oxin 7/2 012 0 2 0
HEXACHLOROBENZENE
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA f
2019
Manufactured
Category Throughput Concentration
FIV-
Manufactured
Wood Combustion 71417 tonlyr 1.20E-07 lb/ton (1) 0.01 Ib/yr
Total Manufactured 0 Ib/yr
Manufacturing Threshold 101b/yr
Reporting Required? No
1. Hexachlorobenzene concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Repo
Processed
Hexachlorobenzene was not processed at this facility.
Otherwise Used
Hexachlorobenzene was not otherwise used at this facility.
C:\Users\mlmahlerWppDalalLocahMicrosoft\Windows\INetCachelContent.Oullook\HDW69WUE12019 MoncuBAEilml Calcs 2020-0317\Hexachlombenzene 7/20/2020
HYDROCHLORIC ACID
SARA 313 THRESHOLD CALCULATIONS
Arauco-.MONCURE,NORTH CAROLINA
2019
Manufactured
Hydrochloric acid (HCl)was produced as a byproduct during fuel combustion.
Category Throughput Concentration
Manufactured
MDF Dryer Outfeed Scrubbers 555,230 MMBtu r 1.57E-03 Ib/MMBtu (1) 131 Ib/yr
PB Dr ers 345,311 MMBtu r 1.57E-03 Ib/MMBtu (1) 542 Ib/yr
Wellons Bypass 0 MMBtu r 1.57E-03 Ib/MMBtu (1) 0 Ib/yr
Total Manufactured 673 Ib/yr
Manufacturing Threshold 25,000 Ib/yr
'Reporting Required? No
Notes: '
.1. HCl emissions from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting, issued 2019,last up
Processed
Hydrochloric acid was not processed at this facility.
Otherwise Used
Hydrochloric acid was not otherwise used at this facility.
C:\Users\mlmahler\A.ppData\LocaRMiemsoft\Windows\INetCache\Content.Outlook\HDW69WUE\2019 Moncu$Ae it l Calcs-2020-03171HCI 7/20/2020
HYDROCHLORIC ACID
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Hydrochloric acid (HCl)was produced as a byproduct during fuel combustion.
Category Throughput Concentration
Manufactured
MDF Dryer Outfeed Scrubbers 555,230 MMBtu r 1.57E-03 Ib/MMBtu (1) 131 Ib/yr
PB Dryers 345,311 MMBtu r 1.57E-03 Ib/MMBtu (1) 542 Ib/yr
Wellons Bypass 0 MMBtu r 1.57E-03'lb/MMBtu (1) 0 Ib/yr
Total Manufactured 673 Ib/yr
Manufacturing Threshold 25,000 Ib/yr
Reporting Required? No
Notes:
1. HCI emissions from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting, issued 2019,last up
Processed
Hydrochloric acid was not processed at this facility.
Otherwise Used
Hydrochloric acid was not otherwise used at this facility.
}
C:\Users\mlmahler\AppData\Local\Microsoft\Windows\INelCache\Content.Outlook\HDW69WUE\2019 Moncul5FCENRI Ca1cs_2020MMHCI 7/20/2020
MANGANESE COMPOUNDS
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Manganese Compounds(MnO)were produced as a byproduct during fuel combustion.
Category Throughput Concentration Conversion Ratio Manganese Compounds
Ib compound/lb m n Manufactured
MDF and PB Natural Gas Combustion 232.96 MMscf/r 1.81E-03 Ib MMBtu 2 1.29 lb MnO/lb Mn 555 lb MnO/yr
MDF Hog Fuel Combustion in Teaford: 50,218,276 Ib/r 1.30E-04 lb Mn/lb (1) 1.29 lb MnO/lb Mn 8,435 lb MnO/yr
MDF Sanderdust Combustion in Teaford: 9,565,386 Ib r 1.02E-04 lb Mn/lb 1 1.29 lb MnO/lb Mn 1,255 lb MnO/r
Diesel Fuel Combustion en ines 1,762 al r 4.40E-08 lb Mn/lb (1,3) 1.29 lb MnO/lb Mn 0.001 lb MnO/r
PB Hog Fuel Combustion in Wellons 0 Ib/vr 1.30E-04 lb Mn/lb 1 1.29 lb MnO/lb Mn 0 lb MnO/r
PB Sanderdust Combustion in dryers: 76,735 698 Ib/vr 1.02E-04 lb Mn/lb 1 1.29 ib MnO/lb Mn 10,067 lb MnO r
Total Manufactured 20,311 Ib/yr
Manufacturing Threshold 25,000lb/ r
Reporting Required? No
Notes:
1.Mean Mn concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated March 2014. '
2.Emission factor obtained from NCASI TB 973,Table 7.2 Control:Mechanical Collector,February 2010.
3.No.2 fuel oil typical density of 7.05 lb/gal(AP-42).
Processed
Manganese was not processed at this facility in concentrations greater than 1.0%.
Otherwise Used
Manganese was not otherwise used at this facility in concentrations greater than 1.0%.
Total Otherwise Used 0 Ib/yr
Otherwise Used Threshold 10,000 Ib/yr
Reporting Required? No
Notes:
1.Mean Mn concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting
issued 2017,last updated March 2010.
2.AP-42 Section 1.4.July 1998,no natural gas value listed in TRI guidance
CWsasNJmaNr4ypDala'imuMWosMWugwsYNetCaNe',CWanLOWookWb.YeeNM1lE�S1BAbncuie AEI Rli Caka�OAd�IMivpanme CanpvunEa B-t 7r20/2020
MERCURY AND MERCURY COMPOUNDS
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Mercury compounds were produced as a byproduct during fuel combustion. Elemental mercury was not manufactured at this facility.
Category Throughput Concentration Hg oxidized Conversion Ratio Mercury Compounds
N (lb compound/lb Manufactured
MDF and PB Natural Gas Combustion 232.96 MMscf/yr 1.50E-01 lb H /1012 scf (1) 23.0% 1.08 lb HgO/lb Hg 8.68E-06 lb HgO/yr
MDF Hog Fuel Combustion in Teaford: 50,218,276 Ib/yr 1.25E-08 lb Hg/lb(dry) (1) 66.2% 1.08 lb HgO/lb Hg 0.2 lb HgO/yr
MDF Sanderdust Combustion in Teaford: 9,565,386 Ib/yr 3.70E-09 lb Hg/lb(dry) (1) 66.2% 1.08 lb HgO/Ib Hg 0.02 lb HgO/yr
PB Diesel Use 1,762 gal/yr 1.40E-09 lb Hg/gal (1) 23.0% 1.08 lb HgO/lb Hg 6.13E-07 lb HgO/yr
PB Hog Fuel Combustion in Wellons: 0 Ib/yr 1.25E-08 lb Hg/lb(dry) (1) 66.2% 1.08 lb HgO/ib Hg 0.00E+00 lb HgO/yr
PB Sanderdust Combustion in dryers: 76,735,698 Ib/yr 3.70E-09 lb Hg/lb(dry) (1) 66.2% 1.08 lb HgO/lb Hg 0.2 lb HgO/yr
Total Manufactured 0.4 Ib r
Manufacturing Threshold 10Ib r
Reporting Required? No
Notes:
1. Mean Hg concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated March 2014.
Processed
Mercury present in wood was processed to make PB and MDF.
Product Name Product Mercur Com ounds
Usage Content Usage
(lb/yr)
MDF Press Production 264,279 ODT/r 2.30E-09 lb Hg/lb wood 1 1.2 Ib r
PB Press Production 179,311 ODT/yr 2.30E-09 lb HgZlb wood (1) 0.8 Ib/yr
Total Processed 1.2 Ib r
Processed Threshold 10.0 Iblyr
Reporting Required? No
Notes:
1. Mean Hg concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated March 2014.
Otherwise Used
Mercury was otherwise used as a trace element in fuels.
Mercury Usage
Category Product Usage Mercury Content Ib r
MDF backup TOH burners 233 MMscf/yr 1.50E-01 lb Hg/1012 scf (1) 0.0 lb Hg/yr
MDF Hog Fuel Combustion in Teaford 50,218,276 Ib/yr 1.25E-08 lb Hg/lb(dry) (1) 0.3 lb Hg/yr
MDF Sanderdust Combustion in Teaford 9,565,386 Ib/yr 3.70E-09 lb Hg/lb(dry) (1) 0.03 lb Hg/yr
PB Thermal Oil Heater 1,762 gal/yr 1.40E-09 lb Hg/gal - (1) 0.0 lb Hg/yr
PB Hog Fuel Combustion in Wellons 0 Ib/yr 1.25E-08 lb Hg/lb(dry) (1) 0.00 lb Hg/yr
PB Sanderdust Combustion in dryers 76,735,698 Ib/yr 3.70E-09 lb Hg/lb(dry) (1) 0.26 lb Hg/yr
Total Otherwise Used 0.6 Ib r
Otherwise Used Threshold 10 Ib r
Reporting Required? No
Notes:
1. Mean Hg concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated March 2014.
C:111aersMlmaM1leMppDahLLoaAMicrosoft\WvgovSUNelCeclwlCONen1.ONbakWOW00NA1E12018 MOMure AEI TRI Caks_30360J1TAfartury CompouMa6-'I 7/20/2020
NAPHTHALENE
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufacturing
Naphthalene was produced as a byproduct during drying,blending,forming,pressing,and fuel combustion.
Category Throughput Production Factor Naphthalene
Manufactured
MDF Generator 22,288 h -hr/ r 9.10E-07 Ib/hp-hr (1) 0.02
MDF Nat Gas Combustion 217 MMscf/yr 6.10E-04 Ib/MMscf (2) 0.13
MDF Dryer Outfeed Scrubbers 555,230 MMBtu/yr 7,44E-05 Ib/MMBtu (3) 41
PB Fire Pump and Backup Generator 87 MMBtu/yr 8.48E-05 Ib/MMBtu (1) 0.007
PB Natural Gas Combustion 16 MMscf/yr 6.10E-04 Ib/MMscf (2) 0.01
PB Dryers 670,670 MMBtu/yr 7.44E-05 Ib/MMBtu (3) 49.9
PB Wellons Bypass 0 MMBtu/yr 7.44E-05 Ib/MMBtu (3) 0.0
PB Gas Tank 11 Ibs of VOC 0.80 % 1 (4) 0.1
Total Manufactured 91
Manufacturing Threshold 25,000
Reporting Required? No
Notes:
1.NC DAQ emissions calculation spreadsheet for engines.
2.Emission factor obtained from NCASI TB 973,Table 7.1 Uncontrolled,February 2010.
3.Mean Naphthalene concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated Marcl
4.VOC Emissions estimated by EPA Tanks Program,V.4.09d
5.Emission factors from NC DAQ's fuel oil spreadsheet-based on AP-42,5th edition,Section 1.3.
Processed
Naphthalene was not processed at this facility.
Otherwise Used
Naphthalene was not otherwise used on the plant site in concentrations greater than 0.1%.
C:\UsersVdmahler%AppData\Local\Microsoft\Windom\INetCache\Conlent.Oullook\HDW69WUE\2019 Moncure AEI TRI Ell.1020-0317\Naphlhalene 7/20/2020
PHENOL
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured,
Phenol was produced as a byproduct during drying, pressing,and fuel combustion.
Phenol
Manufactured
Category Throughput Production Factor (lb/yr)
264,279 ODT/yr 9.48E-03 Ib/ODT (1) 2,506
MDF Dryer Outfeed Scrubbers 32,720 MMBtu/ r 1.98E-05 Ib/MMBtu (2) 1
151,449 MSF/yr 9.00E-02 Ib/MSF (3) . 13,630
PB Dryers 6,097 hr/yr 2.38E-01 Ib/hr (4) 1,451
PB Press 6,097 hr/yr 1.65E-01 Ib/hr (4) 1,006
138,792lb/MSF 4.70E-03lb/MSF (4) 652
PB Wellons By2ass 0 MMBtu/yr 5.29E-04 Ib/MMBtu (2) 0
Total Manufactured 19,246
Manufacturing Threshold 25,000
Reporting Required? No
Notes:
1.AP-42-Could not find these factors to create a more specific reference
2.Emission factors from NCASI TB 973,Table 7.1-Uncontrolled,February 2010
3. Emission factors per NCASI T6770,Table 6.1.2 Mill 132 average.January 1999
4. Mean Phenol concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued
Processed
Phenol was not processed at this facility in concentrations greater than 1.0%.
Otherwise Used
Phenol was not otherwise used at this facility in concentrations greater than 1.0%.
C:\Users\mlmahlerlAppData\LocaftMicrosoft\Windows\INetCache\Content.Outlook\HDW69WUE\2019 MoncuBAS ITRI Calcs_2020-0317\Phenol 7/20/2020
POLYCHLORINATED BIPHENYLS
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Category Throughput Production Factor Phenol
Manufactured
MDF Dryer Outfeed Scrubbers 555,230 MMBtu/yr 8.15E-09 Ib/MMBtu (1) 4.53E-03
Total Manufactured .4.53E-03
Manufacturing Threshold 10
Reporting Required? No
Notes:
1. Emission factors from AP-42-DAQ spreadsheet
Processed
Polychlorinated biphenyls were not processed at this facility.
Otherwise Used
Polychlorinated biphenyls were not otherwise used at this facility.
C:\Users\mlmahler\AppData\LocahMicrosoft\Windows\lNetCache\ConteLOut[ook1HDW69WUE\2019 Moncu8AEI1rRI Calcs 2020-0317\PCBs 7/20/2020
POLYCYCLIC AROMATIC COMPOUNDS
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019 r
Manufactured
Polycyclic aromatic compounds(PACs)were produced as a byproduct during fuel combustion.
PACS
Category Throughput Concentration Manufactured
MDF and PB Natural Gas Combustion 233 MMscf/ r 1.76E-05 Ib MMcf (1) 0.0 Ib/ r
MDF Hog Fuel Combustion in Teaford 50,218,276 Ib r 3.42E-05 Ib ODT (1) 0.4 Ib/yr
MDF Sanderdust Combustion in Teaford 9,565,386 Ib r 3.42E-05 Ib ODT (1) 0.1 Ib/yr
PB&MDF Diesel Use(Engines) 1,762 al r 1.50E-05 Ib M al (1) 0,0 Ib/ r
PB Hog Fuel Combustion in Wellons 0 Ib r 3.42E-05 Ib ODT (1) 0.0 Ib/yr
PB Sanderdust Combustion in dryers 76,735,698 Ib r 3.42E-05 Ib ODT (1) 0.7 Ib/yr
PB Wellons Bygass 0 Iblyr 3.42E-05 lb ODT (1) 0,0 Ib/yr
Total Manufactured 1.2 Ib/yr
Manufacturing Threshold 1 100 Ib/yr
Reporting Required? No
Notes:
1. Mean PAC concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated March
Processed.
Polycyclic aromatic compounds were not processed at this facility.
Otherwise Used
Polycyclic aromatic compounds were otherwise used as a trace element in fuels used at this facility.
PAXITTS
Category Product Usage PAC Content (lb/yr)
Diesel Use 1,762 gallyr 1.00E-05 lb PAC Ib (1,2) 0.1 lb PAC/yF
Total Otherwise Used 0.1 Ib/yr
Otherwise Used Threshold 100 Ib/yr
Reporting Required? No
Notes:
1. Mean PAC concentrations from NCASI Chemical Specific Information for SARA Section 313 Form R Reporting issued 2019,last updated March.
2. No.2 fuel oil typical density of 7.05 lb/gal(AP-42).
I
C:\Usem%mlmahlerWppData\Lom Mlcrosoft\Windows\INetCache\Content.Oullook\HDW69WUE\2019 Moncure AEI QRYC1Ics_2020-0317\PACs 7/20/2020
PROPIONALDEHYDE
SARA 313 THRESHOLD CALCULATIONS
Arauco-MONCURE,NORTH CAROLINA
2019
Manufactured
Propionaldehyde was produced as a byproduct during drying and wood combustion.
Category Throughput Production Factor Propionaldehyde
Manufactured
MDF Teaford Bypass 32,720 MMBtu/ r 3.21E-05 Ib/MMBtu (1) 1
MDF Dryer 264,279 ODT/ r 1.10E-03 Ib/ODT (2) 291
MDF Press 151,449 MSF/ r -5.40E-04 Ib/MSF (2) 82
PB Dryers 6,097 hr/ r 9.30E-02 Ib/hr (3) 567
PB Press 6,097 hr/yr 1.70E-02 Ib/hr (3) 104
Total Manufactured 374
Manufacturing Threshold 25,000
Reporting Required? No
Notes:
1. Emission factors from NCASI TB 973,Table 7.1-Uncontrolled, February 2010
2. Mean Propionaldehyde concentrations fromNCASI Chemical Specific Information for SARA Section 313 Form R Reportingissued 2019,last
Processed
Propionaldehyde was not processed at this facility.
Otherwise Used
Propionaldehyde was not otherwise used at this facility.
C.\UsemkmlmahlerlAppDatalLomllMicrosoft%WlndowsllNetCache\Content.OutlooklHDW69WUE12019 Moncure AEaRI JoIcs_2020-0317Wmpionaldehyde 7/20/2020
Pe
be pi—J30,2121
Arlo n,l/snlee
i"M 11111711 ,il& x" I IOWA—
PnvanA Re1
A-m V.T I- W-end v11 for e
b,
...............
W.17—B .11—1,—1.14 dili-b,,11.1—i.l.I,—
nk
4 In nn II IM1+ I
XOpnwionel UP'..C..MIS M..,ogl
NMI,
0
-------LO b;h,
It
nn Tim
d-L
1 silo Fil,n on Tim
22 b—
ft—". 1 Fibnl c on Tim0.— 11i
GnJ.+IN+I silo 2 lib, 1"', 1
nFTnrunl
tt—w
T.,ml Annual 5--1—b— Z..
I AnnualTI,11.,1
1b,;h...IlipZy by thv
--------------------
1b.— 1 2; 1PSDA.._.
I A..5_Z�1L�11?a"__i"'.1
Lly,
NITIF B.— CB.1.1 Oil
I
yr Hun Ti c
W-1,
11b"
1hi1J1111-.Ai,
14.1
Mnrrrornme
"I P 21
1— ISLA
b.ob.,
-H..) 48 Ibty
7111 b"
IMr
SandMOU(kR
17b.10
(mm.
MiLl,1 3300U1.1 ...
7440 MD—d—11DI; 3M15111'.1-0.02--
P"tiol
_ PB and MDF,Moncure,NC
Permit Number 03449T51
Expires June 30,2021
Air Emissions Inventory Inputs: 2019 Calendar Year
Parameter Quantity Units Source of Input/Notes
PB Prooduction.
Total Natural Gas Usage(from PSNC website) 160,779 1 ccf
Press and Ba filters
PB Production 245,632 m3 Monthly production report from AMS
179,311 ODT/yr Monthly production report from AMS
PB Production 138,792 MSF 3/4"/r
Wood Processed by Mill 164,298 BDT/yr
Operating Hours 6,097 Itr/r Monthly production report from AMS
PGT_Press_Emmisions tag in historian-run for 1-hr intervals and get total for
Press Abort Operating Hours 6,097 hr/ year.
Sanderdust Combusted in D crs: 76,735,698 Ib/r
BackupNatural Gas Usage in D ers: 1.608 1 MMscf/r 10%of total natural gas throughput
Wellons Bypass
Wellons Gas Firing 14 MMscf/r 86%of total natural gas throughput
Pulled from Historian tag PB_OH_PID_GASFLOW_CV r@r 15 minute intervals,
zero values counted and subtracted from total count,divided by 4 to turn into
Wellons Burner Hours 6,097.0 hr/r hours
Ho•Fuel Combusted in Wellons: 0 Ib/r
Backup Diesel Generator and Fire Pump
Fire Pump Engine Op.Hours 31.61br/yr
Backup Generator 0 .Hours 8.8 hr/r
Diesel Fuel Heating Value 0.138 MMBtu/al 40 CFR 98,Subpart C,Table C-1
Gasoline Tank
Tank Throu li ut 7,991.0 gal/r
Total VOC Emissions I I Ilbs Emissions estimated by EPA Tanks program.
Laminating Presses(TFL)
4,524 hrs/yr X Operational Uptime from AMS Monthly Operating Report
Wemhoner Operating Hours 0 lrr/ (started'running end of May 2018)
Wemhoner Annual Production 0 in AMS Monthly Operating Report
Wemhoner Annual Production 0 MSF Board Feet
Steinemann Operating Hours 0 hr/r 8,760 hrs/yr X Operational Uptime from AMS Monthly Operating Report
Steinemann Annual Production 0 rn1 AMS Monthly Operating Report
Steinemann Annual Production 0 MSF Board Feet
Thermal Oil Heater
Natural Gas Usa a 0.643 MMscf/ 4%of total natural.gas throw h ut
TFL Diesel Usage 1 0 gal/yr I From Mark Noyes and Gaines Oil
MDF Production
Total Natural Gas Usage from PSNC website) 2,168,804 Icef
Log Pro essing Line
Log Throu h ut 0.0 tons/ear
Chip Throughput 0 1 tons/year
Bark Throughput 0.0 tons/year
New MDF Plant Cyclones and Ba houses MDF Production Report
Annual Press Production: 268,033 In; MDF production and quarterly reports,AMS Reports
Refiner Abort Cyclone Operation Time 146 hr/yr Refiner Abort Spreadsheet/Semiannual Reports/Production Limit Calcs Report
Fiber Sifter System Filter Operation Time 7,022 hr/r Production Limit Calcs Report
Forming Line Clean-Up Filter Operation Time 7,022 h#yr Production Limit Calcs Report
Biofilter Operating Hours 0 hr/yr
Mat rejects stern Filter Operation Time 395 lir/yr Production Limit Calcs Report
Mat Reject Production 13,909 ODMT/yr Calculated
Saw System Filter Operation Time 7,022 hr/yr Production Limit Calcs Report
Sander System No.I Exhaust Filter Operation Time 7,022 hr/r
Recycled Fiber Silo No.1 Filter Operation Time 395 hr/r Receives Mat Reject
Sander System No.2 Exhaust Filter Operation Time 7,022 hr/r
Sander Dust Silo No.I Filter Operation Time 3,511 hr/r Operate half of sander ran time(switches between silos)
Dry Sawdust Silo Filter Operation Time 7,022 hr/yr
Recycled Fiber Silo No.2 Filter Operation Time 0 hr/ Offline
Sander Dust Silo No.2 Filter Operation Time 3,511 hr/r
MDF Teaford MDF Production Report
Run a historian report using tag U00_MMBTU_TOT with an interval of 1 hour
for the entire reporting year.Then sum the column of mtnbm values for the
Total Annual Teaford Energy Production 522,509 MMBtu/r annual total.Subtract Teaford Abort Total
Total Annual Teaford Bypass Heat Input 32,720 MMBtu/yr From PSD avoidance limitation calculations.
Divide total energy production(rnrnbtu/yr)by conversion factor for wood(17.48
mmbtu/ton);then multiply by 2000 lbs/ton to convert to Ibs;then multiply by the
Hog Fuel Combusted in Teaford: 50,218,276 lb/yr percentage of hog fuel as solid fuel(84%)
Divide total energy production(tmnbtu/yr)by conversion factor for wood(17.48
mmbtu/ton);then multiply by 2000 lbs/ton to convert to lbs;then multiply by the
Sanderdust Combusted in Teaford:1 9,565,386 1 lb/r I percentage of sander dust as solid fuel(16%)
MDF Press and Dryer Scrubbers MDF Production Report
MDF Operating Hours 7,503 hr/r
Teaford Abort Hours: 2,727 hr/r PSD Avoidance Reports
Annual Dryer Production(Normal) 0 ODMT/r
Annual Dryer Production(Biofilter Down) 239,750 ODMT/r ?
Annual Press Production: 151,449 MSF 3/4"/r
Amoral Sander Production 189,016 ODMT/r
Annual Sander Production 151,449 MSF 3/4"/r
Backup natural as-fired dryer burners 1 114 MMscf/
MDF Backup Natural Gas Burners-Hot Oil
#of Burners: 3#
Burner Natural Gas Use: 103 MMscf/r
Total Backup Natural Gas Fired Burner Capacity(ES-
02C and ES-02D): 87.0 MMBtu/hr New 35(2x)mmBTU burners replaced 78.5 mmBTU burner in January 2018
Percent of Total Natural Gas Burner Capacity
(ES-02C and ES-02D): 52.7%
Total Thermal Oil Heater Natural Gas Fired Burner
Capacity(ES-18,19,and 20):I 78.0 MMBta/hr INess Burner permit descriptor change.Ness units replaced in 2019
Percent of Total Natural Gas Burner Capacity
(ES-18,19,and 20), 47.3 %
MDF Backup Diesel Generator
Generator Run Time: 14 1 hr/r Weekly meter reading logs
Fugitive Emissions: Resin Tanks
Resin Tanks in Operation: 3# 1 Matched number with permit
Fugitive Emissions:Ponds and Spray Fields
Pond Capacity: 2,879,000 aU r
Gallons Irrigated:1 2,295,500 1 gal/yr
Off-site Transfers:POTW
Wastewater Shipped Off-Site 1 30,380,808 al/r I Wastewater shipment records
Miseelaneous Facility Information
Natural Gas Heating Value 1 1,020 Btu/scf Pull from gas bills
Fuel Oil Heating Value 1 0.138 MMBtu/al 140 CFR 98,Subpart C,Table C-1
Ash Sent Off-site 1 2,594 ton/r
Prior Year Data
PB Production 118,149 MSF/ From rior yearspreadsheet
MDF Production 1 151,449.2 MSF/yr From prior year spreadsheet
t of 4 Inventory&TRI Inputs
Pre
Pre
Pre
Pre
total san.
10%o
total saro
total sam
Pre
2%of pr
total saro
Pr
72436 MMB'
Pr
2 of 4 Inventory&TRI Inputs
16399.4898 mmbtu
221218 mmbtu
3 of 4 Inventory&TRI Inputs
hog fuel(Jeff
TF[r-935260 pam McMillian) 954.48 lb/ttr
24 days/month
7175 hrs/yr
848. Ib/yr
Sanderdust(Jeff
McMillian) 4450lb/hr
24 days/month
7175 firs/yr
5049 Op firs in 2015 7 a 0 lb/yr
or 1708050
Sanderdust(Myron
Miller) 250001 m^3 l Ib/ft^3
74493 MDF and 43904 HDF in 20151 ft^3=0.02832 m^3
8 7 lb
;ss production Hrs
:ss production Hrs
;ss production Hrs
ss production Hrs
der production Itrs
f press production
der production firs
der production firs
sss production Hrs
ess production lus
der production hrs
2013
ess production hrs 1949
TU/yr for Teaford
Percent of Total
2013
ess production Itrs 1949
tmnBtu/hr #REF!
tmnBtu/hr #REF!
mtnBtu/hr
See individual spreadsheet
4 of 4 Inventory&TRI Inputs
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment: Refiner Abort Cyclone/Dryer
Equipment ID Number: ES-01
Emission Point: CD-01
Control Device: CD-01
2019 Actual Process Throughput:
Operation= 146 hr/yr
2019 Actual Emissions Summary:
CUM PM
Efficiency Uncontrolled and Controlled
Compound - Emission Factor (%) Reference Emissions
PM 3.52 lb/hr - 1 512.16 lb/yr 0.26 tpy
PM10 i 2.5 3.52 lb/hr - 1 512.16 1b/yr 0.26 tpy
Note: Exhaust from the Refiners is routed through the dryers during.normal operation. Emissions during normal
operation are included in the emissions from the dryer.
References:
1. Per Oregon DEQ Emission Factors for Wood Products(AQ-EF02), 0.2 lb PM/bone dry ton for high-efficiency cyclones Y
handling green wood. Annual throughput estimated at 2% of design throughput.Hourly throughput estimated at 17.6 tons
per hour. PM2.5 is assumed equal to PM and PM10.
1 ON MDF-ES-01
ma.p m .ae 1 Iry _. v°Wn°� ••• y! r_vp
cm�wmm cns P88n e. rynwwJ �'R�nw�4 t>.°�veu� yal��ry ��v R. RaommaRewnm
C oa�W�
_ _ _ �4•ln
u�anmu
l [
2019 Actual Emissions Summary(Controlled)
MDF Mill
Refiner Energy System MDF Dryer
Board Cooler Press Sander Sander
Startup Wood-Fired ' Burners Forming Recycled Sander Dust
Cyclone Burner(Wood Enclosure,Energy Fiber Sifter Mat reject Saw System System No.1 System No.2
y (W System,Dryers- (Natural Gas System Filter Line Clean- system Filter Board Cooler Filter Exhaust Fiber Silo Exhaust Silo No.1
(Refiner Burning in Wood Combustion Backup Up Filter Filter No.1 Filter Filter Filter
Compounds CAS Abort) Teaford) Burners)
No.
EP-01 ES-02A ES-02B ES 02C,,ES EP-03 EP-04 EP-05 EP-06B EP-07 EP-08 EP-09 EP-10 EP-12
Criteria Compounds
CO - - 9.82 156.75 4.80 - - - - - - - -NO, - - 5.40 86.21 2.86 - - - - - - - - -
PM - 0.26 8.18 61.14 0.03 2.04 1.93 0.09 - 2.95 3.16 0.00 1.58 0.04
PMio - 0.26 8.18 61.14 0.02 2.04 1.93 0.09 - 2.95 3.16 0.00 1.58 0.04
PMz.5 - 0.26 7.03 61.14 0.02 2.04 1.93 0.09 - 2.95 3.16 0.00 1.58 0.04
SOz - - 0.41 6.53 0.03 - - - - - - - - -
VOC - - 0.28 933.80 0.31 10.54 10.54 0.61 - 0.85 0.84 0.55 ��.84 0.05
Lead - - 7.85E-04 1.25E-02 - - - - - - - - -
HAPs/TAPs
Formaldehyde 50-00-0 - 1.44E-02 5.23E+00 4.29E-03 1.07E+00 1.07E+00 6.14E-02 - 3.03E-02 5.61E-02 3.03E-02 1.68E-03
Lead and Lead Compounds - - 2.72E-04 - - - - - - - - - - -
Man anese - - 4.29E-04 - - - - - - - - - - -
Methanol 67-56-1 - 4.33E-03 2.53E+02 8.27E-01 8.27E-01 4.76E-02 - 7.09E-01 1.70E-01 4.35E-02 1.36E-01 7.55E-03
1 of 4 Emissions Summary
PB'Mill
MDF Diesel Sawdust Flying Cut Off Saw
TFL Nat.Gas Surface Material Surface Formers Steinemann
Recycled Sander Dust MDF Fuel-fired Rock and Pretrim Saws &
Dry Sawdust Resin Tanks- Spray Field- Thermal Oil Laminating Wellons Transport(SL and Mat Dumps ' Finishing
Fiber Silo Silo No.2 Thermal Oil Emergency Metal PB Dryers Production Collection
Silo Filter Fugitive Fugitives Heater(4.7 Presses Furnace Fines from (Wet Material Sander
No.2 Filter Filter Heaters Generator MMBtu/hr Separator (Dry Material
1592 HP ) Ba house Screening) Transport) Baghouse
( ) g Transport System)
EP-13 EP-15 EP-17 EP-18,19,20 ES-21 MDFR-1,2, I-Irrigation Pr-Heatl 3593,3594 3501 1430,1420, 3201 3515 3525 3535 3545
3,4 fugitive 1410,3201
- - 4.31 0.07 - - 0.00 - - 382.62 0.58 - - - -
- - 5.13 0.35 - - 0.00 - - 172.60 0.69 - - - -
0.07 0.00 0.04 0.39 0.02 - - 0.00 0.00 0.04 27.06 0.05 0.02 0.02 0.02 0.02
0.07 0.00 0.04 0.39 0.02 - - 0.00 0.00 0.04 27.06 0.05 0.02 0.02 0.02 0.02
0.07 0.00 0.04 0.39 0.02 - - 0.03 0.00 0.04. 27.06 0.05 0.02 0.02 0.02 0.02
- 1 0.00 0.02 - - 0.00 - - 0.08 0.00 - - - -
0.06 0.55 0.05 0.00 0.03 0.02 0.00 0.03 0.00 15.12 163.45 0.04 59.30 0.83 6.41 2.98
- - 2.56E-05 - - - 0.00E+00 - - 1.65E-03 0.00 - - -
- 5.61E-02 1.68E-03 3.84E-03 6.15E-06 1.31E-02 1.92E-03 2.41E-05 0.00E+00 3.28E-02 6.82E+00 5.19E-04 5.69E-02 1.27E-01 1.60E-01 4.16E-01
- - - - 7.02E-07
- - 1.95E-05 4.68E-07 - - 1.22E-07 - - 1.17E-02 2.63E-06 - - -
2.40E-03 4.35E-02 7.55E-03 - - - - - - 5.39E-01 9.65E+00 8.06E-01 2.47E-02 6.58E 02 9.94E-02
2 of 4 Emissions Summary
C •.� M
j
Sander Filter Oversize PB Diesel
Steinemann Schelling Diesel Fuel-
Calibrating Saw Board PB Press and Transport to PZKR Green Pallmann Mill Gasoline fired Fire Fuel-fired Dry Waste Wastewater
3545&3565 (Dry Material Emergency System Lagoons-
Sander Trim Board Cooler Sanderdust Chip Makers (Dry
Mill Tank Pump Engine Generator
Baghouse Transfer ( (347 HP (Hammermill) Fugitives
Silo) Transport) ) (465 HP)
3565 3555 DEF,PBBC 3575 3585 3595 I-GAS I-DFP-1 I-ODG 3577 I-Wastewater Total Emissions Total Emissions Total Emissions
Ponds DF PB (Facility-Wide)
- 10.53 - - - - 0.04 0.00 - - 175.8 tpy 393.8 tpy 569.5 tpy
- - 1.21 - - - - 0.17 0.02 - - 99.9 tpy 174.7 tpy 274.6 tpy
1.97 0.01 26.09 1.77 9.69 0.01 - 0.01 0.00 0.05 - 81.9 tPY 66.8 tpy 148.8 tpy
1.97 0.01 26.09 1.77 9.69 0.01 - 0.01 0.00 0.05 - 81.9 tpy 66.8 tpy 148.7 tpy
1.97 0.01 8.91 1.77 9.69 0.01 - 0.01 0.00 0.05 - 80.8 tpy 49.7 tpy 130.5 tpy
- - - - - - - 0.01 0.00 - - 7.0 tpy 0.1 "tT)V2.30E+01.
7.1 tpy
1.16 2.51 120.40 1.57 8.51 0.59 - 0.01 0.00 27.06 2.40E-03 959.9 t y 410.01,369.9 tpy
- - - - - - - - 0.0 y 0.00.0 tDv
1.37E-01 3.65E-02 6.72E+00 1.$6E-01 6.64E-02 6.69E-03 - 4.53E-05 6.14E-06 5.49E-01 2.40E-03 7.64E+00 .1.53E+01 y
2.72E-04 y0.00E+002.72E-04E-04 1.17E-021.21E-02
2.99E-02 1.63E-01 1.66E+01 4.04E-02 4.41E-01 5.26E-02 - - - 4.00E-01 - 2.56E+02 t y I 2.89E+01tplr 2.85E+02 t y
3 of 4 Emissions Summary
NC DEQ
DeMinimis Reporting Required?
(lb/yr) (Y/N)?
No Deminimis Value
No Deminimis Value
No Deminimis Value
No Deminimis Value
No Deminimis Value
No Deminimis Value
No Deminimis Value
No Deminimis Value
No Deminimis Value
No Deminimis Value
10 Yes
1 No
10 Yes
1000 Yes
4 of 4 Emissions Suaunmy
PB and MDF,Moncure,NC
Permit Number 03449T51
Emission Unit Equipment/Proces Teaford Energy System(Abort)
Equipment ID Number: ES-02A
Emission Point:
Control Device: CD-02A
2019 Actual Process Throughput:
Energy System(Teaford)Production= 32,720 MMBtu/yr
PM/Metals Control Efficiency= 0%
VOC Control Efficiency= 46%
2019 Actual Emissions Summary:
Control
Efficiency
Compound Emission Factor (%) Reference Uncontrolled and Controlled Emissions
PM, 0.50 lb/MMBtu 2 16,360.21 Ib/yr 8.18 tpy
PM,.5 0.43 Ib/MMBtu 2 14,069.78 Ib/yr 7.03 tpy
NOx 0.33 Ib/MMBtu 2 10,797.74 Ib/yr 5.40 tpy
CO 0.6lb/MMBtu 1 19,632.25lb/yr 9.82
FIL-ead
0.025 Ib/MMBtu I 818.01 Ib/yr 0.41 tpy
O.Ol7 Ib/MMBtu 3 556.25 lb/yr 0.28 tDy
4.80E-05 Ib/MMBtu 1 1.57E+00 lb/r 7.85E-04 tpy
4 6,856,738 lb/yr 3,428.37 tpy
206.793 Ib/MMBtu 5 6,766,365 1b/yr 3,383.18 tpy
0.016 Ib/MMBtu 5 519.38 Ib/yr 0.26 tpy
N,O 0.008 Ib/MMBtu 5 259.69 Ib/yr 0.13 tpy
<.,
Acetaldehyde 1.22E-04 Ib/MMBtu 46% 6 2.17E+00 lb/r 1.09E-03 2.172
Aceto henone 1.84E-06 Ib/MMBtu 6 6.02E-02 lb/r 3.01E-05 tpy 0.060
Acrolein 3.16E-05 Ib/MMBtu 46% 6 5.62E-01 lb/ r 2.81E-04 tpy 0.562
Antimony&Compounds. 4.98E-07 Ib/MMBtu 7 1.63E-02 lb/yr 8.15E-06 tpy 0.016
Arsenic&Compounds 1.84E-06 Ib/MMBtu 7 6.02E-02 Ib/r 3.01E-05 tpy 0.060
Benzene 2.35E-04lb/MMBtu 6 7.69E+00lb/ 3.84E-03 tpy 7.689
Benzo a rene 2.60E-06 Ib/MMBtu 8 8.51E-02 lb/r 4.25E-05 tvv 0.085
Beryllium 3.41E-07 Ib/MMBtu 7 .1.12E-02 Ib/ r 5.58E-06 tpy 0.011
Cadmium 1.85E-06 Ib/MMBtu 7 6.05E-02 Ib/r 3.03E-05 toy 0.061
Carbon tetrachloride 1.26E-05 lb/MMBtu 6 4.12E-01 Ib/r 2.06E-04 tpy 0.412
Chlorine 7.90E-04 Ib/MMBtu 8 2.58E+01 lb/r 1.29E-02 tpy 25.849
Chlorobenzene 1.66E-05 Ib/MMBtu 6 5.43E-01 lb/r 2.72E-04 tpy 0.543
Chloroform 3.52E-05 Ib/MMBtu 6 1.15E+00 Ib/r 5.76E-04 tpy 1.152
Chromium 5.06E-06 Ib/MMBtu 7 1.66E-01 Ib/r 8.2811-05 tpy 0.166
Chromium VI 2.35E-07 lb/MMBm 7 7.69E-03 IbJ r 3.84E-06 tpy 0.008
Cobalt compounds 1.97E-07 Ib/MMBtu 7 6.45E-03 lb/r 3.22E-06 tpy 0.006
Dinitro henol 2,4- 1.30E-07 Ib/MMBtu 6 4.25E-03 Ib/r 2.13E-06 tpy 0.004
DEHP 4.70E-08 Ib/MMBtu 8 1.54E-03 lb/r 7.69E-07 tpy 0.002
Ethyl benzene 1.76E-05 Ib/MMBtu 6 5.76E-01 lb/i• 2.88E-04 tpy 0.576
Ethylene dichloride 2.90E-05 Ib/MMBtu 8 9.49E-0I lb/r 4.74E-04 0.949
Formaldehyde 8.83E-04 Ib/MMBtu 6 2.89E+01 lb/r 1.44E-02 tpy 28.892
12 3,6,7,8-HCDD 1.60E-06 lb/MMBn1 8 5.24E-02 Ib/T 2.62E-05 tpy 0.052
Hydrogen chloride 1.57E-03 lb/MMBtu 6 5.14E+01 Ib/r 2.57E-02 tpy 51.371
Lead and Lead compounds 1.66E-05 lb/MMBtu 7 5.43E-01 Ib/r 2.72E-04 tpy 0.543
Manganese&compounds 2.62E-05 Ib/MMBtu 7 8.57E-01 Ib/r 4.29E-04 tpy 0.857
Mercury 6.61E-07 Ib/MMBtu 7 2.16E-02 lb/ r 1.08E-05 tpy 0.022
Methanol 4.87E-04 Ib/MMBtu 46% 6 8.67E+00 Ib/ r 4.33E-03 8.669
COPS►' of RECORD Date Submitted: 6/30/2020 09:26: 13
Inventory Certification Form(Title V) (4Lff�
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
These forms must be completed and returned even if the facility did not operate or emissions were zero
The legally defined "Responsible Official" of record for your facility is Jeff McMillian
This person or one that meets the definition below must sign this certification form.
Phe official submitting the information must certify that he/she complies with the requirements as specified in Title 15A NCAC
?Q.0520(b)which references and follows the federal definition. 40 CFR Part 70.2 defines a responsible as meaning one of the
following:
1. For a corporation: a president, secretary,treasurer,or vice-president of the corporation in charge of a principal business
function,or any other person who performs similar policy or decision making functions for the overall operation of one or
more manufacturing,production,or operating facilities applying for a or subject to a permit and either
i. the facilities employ more than 250 persons or have gross annual sales or expenditures exceeding$25 million(in
second quarter 1980 dollars); or
H. the delegation of authority to such representatives is approved in advance by the permitting authority;
2. For partnership or sole proprietorship;a general partner or the proprietor,respectively;
3. For a municipality, state, federal,or other public agency includes the chief executive officer having responsibility for the
overall operations of a principal geographic unit of the agency(e.g., a Regional Administrator of EPA).
CERTIFICATION STATEMENT:
(Important:Legally Responsible Official.read and sign after all submissions are final.)
I certify that I am the responsible official for this facility, as described above, and hereby certify that the information contained in
this air emissions report, including attached calculations and documentation, is true, accurate and complete. (Subject to legal
penalties of up to$25,000 per occurrence and possible imprisonment as outlined in G.S. § 143-215.3(a)(2))
Responsible Official's Signature Below (use blue ink): Date Signed: (Pilo Ujo
Printed Name: Jeff McMillian
Signature: it it A a�.�
This form applie to qitle V facilities. If this facility is not classified asTitle V,please telephone your regional office Emission
Inventory Contact at once for proper forms.
Email address of Responsible Official: Jeff.McMillian@arauco.com
NC Dept of Environmental Quality
JUL 15 2020
Information on this Form cannot be held confidential
Kalcigh Regional Office
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
Listing of Emission Sources and Control Devices on Permit.See instructions
*ES ID on *ES Description *CS ID *CS Description *CD ID's
Air Permit
Core layer single pass,rotary drum
(#1)dryer with one wood suspension CD-1421,CD-
dust/natural gas-fired burner(50 Three multi-cyclones,Wet electrostatic 143 1420 million Btu per hour maximum rated CS-56 precipitator CD-PB-
heat input) [PSD,MACT Subpart WESP
DDDD]
Surface layer triple pass,rotary drum
(0)dryer with one wood suspension CD-1421,CD-
1430 dust/natural gas-fired burner(60 CS-56 Three multi-cyclones,Wet electrostatic 1431,CD-PB-
million Btu per hour maximum rated precipitator WESP
heat input) [PSD,MACT Subpart
DDDD]
One"Wellons"unit operating as a:a)
wood suspension dust-fired burner
(40 million Btu per hour maximum
rated heat input);or ab)natural gas-
fired burner(21.8 million Btu per
hour maximum rated heat input);
exhausting to either surface layer
3201 triple pass,rotary drum(#3)dryer[ID
No. 1430] and/or core layer single
pass,rotary drum(#1)dryer[ID No.
1420]and/or core layer single pass,
rotary drum(#2)dryer[ID No.
1410]c)natural gas-fired indirect
heat exchanger(21.8 million Btu per
hour maximum rated heat
input)[PSD,MACT Subpart DDDD]
3501 Sawdust Rock and Metal Separator CS-29 Cyclone and Bagfilter(2,410 square feet of CD-SC,CD-3501
[PSD,MACT Subpart DDDD] filter area)for rock/inetal separator PB process
Surface Material Transport(SL fines CD-3500,3412,
3515 from screening operation) [PSD, CS-35 Six Simple cyclones and Bagfilter for the Fi T CD-3512B,CD-
MACT Subpart DDDD] nes ransport system 3515
Surface Formers and Mat Dumps Three Cyclones,Bagfilter(6,918 square feet CD-3520A,CD-
3525 [PSD,MACT Subpart DDDD] CS-14 of filter area) 3520B,CD-3521,
CD-3525
Flying Cut Off Saw'Pretrim Saws & CD-3530 CD-
Three Cyclones,Bagfilter(6,918 square feet '
3535 Production Collection[PSD,MACT CS-15 of filter area) 3531,CD-3533,
Subpart DDDD] CD-3535
Particleboard Mill Steinemann
3545 Finishing Sander[PSD,MACT CS-30 Bagfilter(6,918 square feet of filter area)aka CD-5001
Subpart DDDD] ID 3565
Particleboard Mill Steinemann Bagfilter(6,924 aquare feet of filter area)aka
3565 Calibrating Sander[PSD,MACT CS-31 ID 3545 CD-2006
Subpart DDDD]
Sander Filter Transport for Filters Cyclone,Bagfilter(1,159 square feet of filter
3575 3545 &3565 [PSD,MACT Subpart CS-17 3540B,CD-3575
DDDD] area)
Simple cyclone,Bagfilter(4,068 square feet
Dry waste tranport system[PSD CD-3532 CD-
MACT Subpart DDDD] CS-19 of filter area)for dry waste hammermill 3577
transport
3585 1 PZKR Green Chip Makers[PSD, CS-32 Bagfilter(4,880 square feet of filter area)aka CD-3585
MACT Subpart DDDD] ID 3585
3593 Short Cycle Laminating Press CS-36 Reverse flow bagfilter(Maximum air-to-cloth CD-3593
ratio of 4.1 ACFM/total filter surface area).,
3594 Short Cycle Laminating Press CS-36 Reverse flow bagfilter(Maximum air-to-cloth CD-3593
ratio of 4.1 ACFM/total filter surface area).,
3595 Oversize material Pallmann mill CS-16 Two Simple cyclones,Bagfilter(5,767 square CD-3595
[MACT Subpart DDDD] feet of filter area)
Wood chip piles-Medium Density
6001 Fiberboard Mill[MACT Subpart
DDDD]
6003 Wood Fuel Pad and Boiler Transfers
[MACT Subpart DDDD]
7001 or SP-1 Truck/Rail Chip Handling System,
Enclosed[MACT Subpart DDDD]
Wood chip piles-Medium Density
7002-A Fiberboard Mill[MACT Subpart
DDDD]
Wood chip piles-Medium Density
7002-B Fiberboard Mill[MACT Subpart
DDDD]
Wood chip piles-Medium Density
7002-C Fiberboard Mill[MACT Subpart
DDDD]
Wood chip piles-Medium Density
7002-D Fiberboard Mill [MACT Subpart
DDDD]
Truck/Rail Sawdust Handling
7004 or SP-2 System,Enclosed[MACT Subpart
DDDD]
7005-D Sawdust transport to A-frame
[MACT Subpart DDDD]
7005-E Sawdust transport to A-frame
[MACT Subpart DDDD]
7005-F Sawdust transport to A-frame
[MACT Subpart DDDD]
7005-G Sawdust transport to A-frame
[MACT Subpart DDDD]
7006 Wood Fuel Pad and Boiler Transfers
[MACT Subpart DDDD]
7007 Wood Fuel Pad and Boiler Transfers
[MACT Subpart DDDD]
7010 Particle Board Mill Truck Dump
[MACT Subpart DDDD]
7012 Dump bunkers and CL dryer dump
[MACT Subpart DDDD]
7014 Dump bunkers and CL dryer dump
[MACT Subpart DDDD]
7019 Fiber dump and reject filter bins
[MALT Subpart DDDD]
7022 Wood Fuel Pad and Boiler Transfers
[MALT Subpart DDDD]
7024 Particleboard Mill feed bins'[MACT
Subpart DDDD]
7025 Scale transfer conveyors[MACT
Subpart DDDD]
7026 Fiber dump and reject filter bins
[MACT Subpart DDDD]
7027 Hog fuel hopper[MACT Subpart
DDDD]
7029 Dump bunkers and CL dryer dump
[MACT Subpart DDDD]
7040 Particleboard Mill chip transfer
[MACT Subpart DDDD]
7044 Particleboard Mill chip transfer
[MACT Subpart DDDD]
7046 Particleboard Mill chip transfer
[MACT Subpart DDDD]
7048 Particleboard Mill chip transfer
[MACT Subpart DDDD]
7050 Particleboard Mill chip transfer
[MACT Subpart DDDD]
7052 Wood residue bunkers [MACT
Subpart DDDD]
7054 Wood residue bunkers [MACT
Subpart DDDD]
7055 Wood residue bunkers [MACT
Subpart DDDD]
7056 Wood residue bunkers [MACT
Subpart DDDD]
DEF-2010 Particleboard Press [PSD,MACT
Subpart DDDD]
Venturi and packed bed scrubber(35 gallons
Refiner[PSD,MACT Subpart per minute minimum injection rate),Ventun'
ES-01 DDDD] CS-50 and packed bed scrubber(35 gallons per CD02,CD14
minute minimum injection rate),
Energy System consisting of one Urea/water injection system,Venturi and
packed bed scrubber(35 gallons per minute
ES-02-A dry/wet wood/woodwaste-fired CS-42 minimum injection rate),Venturi and packed CD02-A,CD02,
burner(205 million Btu per hour heat CD14
input) [PSD,MACT Subpart DDDD] bed scrubber(35 gallons per minute minimum
injection rate),
Venturi and packed bed scrubber(35 gallons
Two Stage Dryer System[PSD per minute minimum injection rate),Venturi
ES-02-B MACT Subpart DDDD] CS-50 and packed bed scrubber(35 gallons per CD02,CD14
minute minimum injection rate),
Venturi and packed bed scrubber(35 gallons
Backup natural gas-fired dryer burner per minute minimum injection rate),Urea/water CD02,CD02-A,
ES-02-C-1 (35 million Btu per hour heat input) CS-41 injection system,Venturi and packed bed CD14
[PSD,MACT Subpart DDDD] scrubber(35 gallons per minute minimum
injection rate),
Venturi and packed bed scrubber(35 gallons
Backup natural gas-fired dryer burner per minute minimum injection rate),Urea/water CD02,CD02-A,
ES-02-C-2 (35 million Btu per hour heat input) CS-41 injection system,Venturi and packed bed CD14
[PSD,MACT Subpart DDDD] scrubber(35 gallons per minute minimum
injection rate),
Backup natural gas-fired dryer burner Venturi and packed bed scrubber(35 gallons
ES-02-D (17 million Btu per hour heat input) CS-50 per minute minimum injection rate),Venturi CD02,CD14
[PSD,MACT Subpart DDDD] and packed bed scrubber(35 gallons per
minute minimum injection rate),
ES-03 Fiber Sifter System[PSD,MACT CS-43 Fabric Filter(12,290 square feet of filter area), CD03
Subpart DDDD]
ES-04 Forming Line Clean-Up System CS-44 Fabric Filter(9,346 square feet of filter area), CD04
[PSD,MACT Subpart DDDD]
ES-05 Mat Reject System[PSD,MACT CS-45 Fabric Filter(9,346 square feet of filter area), CD05
Subpart DDDD]
Venturi and packed bed scrubber(35 gallons
MDF Board Cooler and Press Hall per minute minimum injection rate),Venturi
ES-06-B [PSD,MACT Subpart DDDD] CS-50 and packed bed scrubber(35 gallons per CD02,CD14
minute minimum injection rate),
ES-07 Saw System[PSD,MACT Subpart CS46 Fabric Filter(6,793 square feet of filter area), CD07
DDDD]
ES-08 Sander System No.1 [PSD,MACT CS-47 Fabric Filter(12,290 square feet of filter area), CD08
Subpart DDDD]
ES-09 Recycled Fiber Silo No.1 [PSD, CS48 Bin Vent Filter(226 square feet of filter area), CD09
MACT Subpart DDDD]
ES-10 Sander System No.2 [PSD,MACT CS-49 Fabric Filter(12,290 square feet of filter area), CD10
Subpart DDDD]
ES-12 Sander Dust Silo No. 1 [PSD,MACT CS-52 Bin Vent Filter(226 square feet of filter area), CD12
Subpart DDDD]
ES-13 Dry Sawdust Silo[PSD,MACT CS-53 Bin Vent Filter(226 square feet of filter area), CD13
Subpart DDDD]
ES-15 Recycled Fiber Silo No.2 [PSD, CS-54 Bin Vent Filter(226 square feet of filter area), CD15
MACT Subpart DDDD]
Venturi and packed bed scrubber(35 gallons
MDF Press and Press Hall[PSD per minute minimum injection rate),Venturi
ES-16 MACT Subpart DDDD] CS-50 and packed bed scrubber(35 gallons per CD02,CD14
minute minimum injection rate),
ES-17 Sander Dust Silo No.2 [PSD,MACT CS-55 Bin Vent Filter(226 square feet of filter area), CD17
Subpart DDDD]
Natural gas-fired hot oil heater(30.4
ES-18 million Btu per hour maximum heat
input) [PSD,NSPS De,MACT
DDDDD]
Natural gas-fired hot oil heater(30.4
ES-19 million Btu per hour maximum heat
input) [PSD,NSPS Dc,MACT
DDDDD]
Natural gas-fired hot oil heater(30.4
ES-20 million Btu per hour maximum heat
input) [PSD,NSPS Dc,MACT
DDDDD]
Diesel Fuel-fired Emergency
ES-21 Generator(1592 Brake Horsepower
output) [PSD,MACT ZZZZ]
EVAP-1.19C Wastewater evaporator[MACT
DDDD]
Diesel Fuel-fired Fire Pump Engine
I-DFP-1 (347 Brake Horsepower output)
[MACT ZZZZ,NSPS IIII]
I-GAS One 500 gallons above ground
gasoline storage tank
I-Irrigation Spray Irrigation Field Fugitives
fueitiv
I-MDFR-1 MDF resin storage tank[MACT
DDDD]
I-MDFR-2 MDF resin storage tank[MACT
DDDD]
I-MDFR-3 MDF resin storage tank[MACT
DDDD]
I-MDFR-4 MDF resin storage tank[MACT
DDDD]
Diesel-fired emergency generator
I-ODG (465 horsepower,3026 million Btu
per hour heat input)[MACT ZZZZ]
I-Spray Paints and striping for marking wood
Paints panels[MACT DDDD]
I-TANKI Above ground propane storage tank,
1000 gallons
I-TANK2 Above ground propane storage tank,
1000 gallons
I-TANK3 Above ground propane storage tank,
1000 gallons
I-TANK4 Above ground propane storage tank,
1000 gallons
I-VENTS Roof ventilators
I-Wastewater Fugitives from wastewater lagoons
ponds
PB-BC Particleboard Cooler[PSD] [MACT
Subpart DDDD]
Natural gas or No.2 fuel oil-fired hot
oil heater(4.7 million Btu per hour
Pr-Heatl heat input)used with short cycle
laminating presses [Case-by-Case
MACT]
SP Fuel Sawdust and Chip Storage Piles
[MACT Subpart DDDD]
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
Emission Source& Operating Scenario List- See Instructions
*ES Group ID *ES ID SOS ID SOS Description
GR2 I-MDFR-1,I-MDFR-2,1- 78 MDF Resin Tanks
MDFR-3,I-MDFR-4
GR3 ES-18,ES-19,ES-20 79 MDF Backup Natural Gas-fired Thermal
Oil Burners
G-51 1420, 1430 3 particleboard dryers
3201 36 Wellons Bypass for PB process
3501 21 Rock and metal separator sawdust cleaning
system
3515 22 Fines transport systems
3525 23 Wet(green)material transport systems
3535 24 Dry material transport systems
3545 25 Steinmann sander for PB process
3555 27 Board trim and transfer system
3565 26 PB sanderdust transport for sander
3575 28 Sanderdust silo transport system
3577 35 Dry waste hammermill tranport system
3585 29 Maker exhaust system
Wemhoner-Short cycle laminating press
3593 43 designed to laminate MDF and/or
Particleboard with overlay
Short Cycle Laminating press designed to
3594 48 laminate MDF and/or Particleboard with
overlay
3595 30 Dry material SL mill transport
6001 NONE NONE
6003 NONE NONE
7001 or SP-1 NONE NONE
7002-A NONE NONE
7002-B NONE NONE
7002-C NONE NONE
7002-D NONE NONE
7004 or SP-2 NONE NONE
7005-D NONE NONE
7005-E NONE NONE
7005-F NONE NONE
7005-G NONE NONE
7006 NONE NONE
'7nn7 ATnTTU MnATL
7014 NONE NONE
7015 NONE NONE
7019 NONE NONE
7022 NONE NONE
7024 NONE NONE
7025 NONE NONE
7026 NONE NONE
7027 NONE NONE
7029 NONE NONE
7040 NONE NONE
7044 NONE NONE
7046 NONE NONE
7048 NONE NONE
7050 NONE NONE
7052 NONE NONE
7054 NONE NONE
7055 NONE NONE
7056 NONE NONE
DEF-2010 4 Particleboard press
50 Refiners
ES-01
74 Refiner Startup Cyclone
51 Wood Burning in Energy Plant
ES-02-A Energy System Bypass Mode
75 (25MMBtu/hr)
ES-02-B 69 Two Stage Dryer System-Wood Drying
MDF Backup Natural Gas Dryer Burners
ES-02-C-1 86 (ES-02C and ES-02D)Combined 87
mmBTU/hr Firing Rate
MDF Backup Natural Gas Dryer Burners
ES-02-C-2 87 (ES-02C and ES-02D)Combined 87
mmBTU/hr Firing Rate
MDF Backup Natural Gas Dryer Burners
ES-02-D 88 (ES-02C and ES-02D)Combined 87
mmBtu/hr Firing Rate
ES-03 53 Fiber Sifter System
ES-04 54 Forming Line Clean-Up System
ES-05 55 Mat Reject System
ES-06-B 56 MDF Board Cooler
ES-07 57 Saw System Filter
ES-08 58 Sander System No.l Exhaust Filter
ES-09 59 Recycled Fiber Silo No. I Filter
ES-10 60 Sander System No.2 Exhaust Filter
ES-12 61 Sander Dust Silo No. 1 Filter
ES-13 62 Dry Sawdust Silo Filter
ES-15 63 Reject Fiber Silo No.2 Filter
ES-16 49 Scrubber controlling press
ES-17 64 Sander Dust Silo No.2 Filter
ES-21 80 MDF Emergency,Generator Operation
EVAP-1.19C 85 Wastewater evaporator
I-DFP-1 76 Diesel-fired fire pump engine operation
I-GAS 41 DOUBLE WALLED STORAGE TANK
I-Irrigation fugitiv 82 Fugitives from spray irrigation system
I-Spray Paints NONE NONE
I-TANK1 NONE NONE
I-TANK2 NONE NONE
I-TANK3 NONE NONE
I-TANK4 NONE NONE
I-VENTS NONE NONE
I-Wastewater ponds 83 Fugitives from wastewater ponds
PB-BC 39 Particle Board Cooler
Natural gas or No.2 fuel oil-fired oil heater
Pr-Heatl 46 (4.7MMBTU.hr)used with short cycle
laminating presses
SP NONE NONE
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) Group GR2 consisting of I-MDFR-1, I-MDFR-2, I-MDFR-3, I-MDFR-4
or Emission Source Group ID
2. Emission Source Description : MDF Resin Tanks
3. Operating Scenario ID/ OS - 78/1\4DF Resin Tanks
Description:
4. SCC Number/Description: 40799999/1\4iscellaneous ; Other Not Classified
5. Throughput/units in 2019: 8736 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm)
Rectangle(L x Vl�
(in 0.1 feet)
FUGRE FUGITIVE (NO
S STACK) 1 72 Area= 1 Resin Fugitive
Operating Scenario: OS - 78 Emission Source/Group ID: GR2
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% I.June-Aug. 25% Sept:-Nov. 25%
2019 1 2019 2019 12019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants
Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08
NOx NOx 08
TSP TSP 08
PM10 PM10 08
PM2.5 PM2.5 08
S02 S02 08
VOC VOC 0.02 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 26.28 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) Group GR3 consisting of ES-18, ES-19, ES-20
or Emission Source Group ID
Z. Emission Source Description : MDF Thermal Oil Heaters
3. Operating Scenario ID/ OS - 79/MDF Backup Natural Gas-fired Thermal Oil Burners
Description:
4. SCC Number/Description: 10300602/Natural Gas ; 10-100 Million Btu/hr
5. Throughput/units in 2019: 103' E6FT3S/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one EPP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/see) Rate(Acfm)
Rectangle(L x Vl�
(in 0.1 feet)
ES 19 VERTICAL 10 1 72 0.1 4.71 Thermal Oil Heater
STACK No. 2
ES 18 VERTICAL 10 1 72 0.1 4.71 Thermal Oil Heater
STACK No. 1
1 72 0.1 4.71 Thermal Oil Heater
ES20 VERTICAL 10
STACK No. 3
Operating Scenario: OS - 79 Emission Source/Group ID: GR3
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
t2. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 1 2019 2019
U. Actual Emissions per Pollutant Listed :
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 4.31 08
NOx NOx 5.13 08
TSP TSP 0.39 08
PM10 PM10 0.39 08
PM2.5 PM2.5 0.39 08
S02 S02 0 08
VOC VOC 0 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor COIItr01
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Arsenic Unlisted
Compounds ( Specify & ASC-Other 0.0205 08
Component of ASC)
Benzene 71-43-2 0.2153 08
Beryllium Compound,
Unlisted (Specify& BEC-Other 0.0012 08
Component of BEC)
Cadmium Metal
(elemental unreacted, 7440-43-9 0.1128 08
Component of CDC)
Chromium Unlisted CRC_
Compounds (Specify& Other 0.1435 08
Component of CRC)
Cobalt Unlisted COC-
Compound (Specify& Other 0.0086 08
Component of COC)
Manganese Unlisted
MNC-
Compounds (Specify & 0.039 08
Component of MNC) Other
Mercury,vapor 7439-97-6 0.0267 08
(Component of HGC)
Naphthalene (Component of POMTV) 91-20-3 0.0625 08
Nickel metal(Component 7440-02-0 0.2153 08 ,
of NIC)
Polycyclic Organic Matter
(Inc PAH, dioxins, etc. NC - POM 0.0644 08
& AP 42 historic
amorphous glob)
Toluene 108-88-3 0.3486 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory- Calendar Year 2019
1.Emission Source ID(from permit) Group G-51 consisting of 1420, 1430
or Emission Source Group ID
Z. Emission Source Description : particleboard dryers
3. Operating Scenario ID/ OS - 3/particleboard dryers
Description:
4. SCC Number/Description: 30700610/Particleboard Manufacture ; Direct Wood-fired Rotary Dryer,
Hardwoods
5. Throughput/units in 2019: 100 E3FT2/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-56 CD-1421 High efficiency multi-cyclone with 4 tubes, each 80 inches in
diameter
2 CS-56 CD-1431 High efficiency multi-cyclone with 2 tubes, each 132 inches in
diameter
3 CS-56 CD-PB-WESP Wet electrostatic precipitator
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Aefm)
Rectangle(L x W)
(in 0.1 feet)
1515 VERTICAL 114.8 12 200 36.8 249718.91 vertical erp on
STACK dryers
Operating Scenario: OS - 3 Emission Source/Group ID: G-51
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 1 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 2019
13. Actual Emissions per Pollutant Listed :
kttach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code Met after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Emissions- Emission
Criteria pollutant Control Emission Ef
(NAAQS) Criteria Estimation Efficiency
Pollutants Code pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 382.62 08 0
NOx NOx 172.6 08 0
TSP TSP 27.06 08 98
PM10 PM10 27.06 08 98
PM2.5 PM2.5 27.06 08 80
S02 S02 0.08 08 0
VOC VOC 163.45 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS eth Efficiency Factor Control
(Pounds/Ycar) Mod Code (Net after all controls)
(See Instructions)
2019
Acetaldehyde 75-07-0 6452 08 0
Acrolein 107-02-8 1978 08 0
Arsenic Unlisted
Compounds ( Specify & ASC-Other 0.214 08 0
Component of ASC)
Benzene 71-43-2 157 08 0
Benzo(a)pyrene
(Component of POMTV & 50-32-8 1 08 0
POM7) .
Bromine 7726-95-6 16 08 0
Cadmium Metal
(elemental unreacted, 7440-43-9 0.249 08 0
Component of CDC)
Chlorine 7782-50-5 527 08 0
Chromium (VI) & CHROM6 0.182 08 0
compounds CPDS
Chromium Unlisted CRC-
Compounds (Specify & Other 0.537 08 0
Component of CRC)
Cobalt Unlisted COG
Compound (Specify & Other 0.313 '08 0
Component of COC)
Cumene 98-82-8 589 08 0
Formaldehyde 50-00-0 13634 08 0
Hexane, n- 110-54-3 195 08 0
Hydrogen chloride 7647-01-0 1048 08 0
(hydrochloric acid)
Manganese Unlisted _
Compounds (Specify & MNC 23 08 0
Component of MNC) Other
Mercury, vapor(Component of HGC) 7439-97-6 0.268 08 0
Methanol 67-56-1 19295 08 0
Methyl ethyl ketone 78-93-3 1668 08 0
Methyl isobutyl ketone 108-10-1 243 08 0
Methylene chloride 75-09-2 234 08 0
Naphthalene (Component 91-20-3 27 08 0
of POMTV)
Nickel metal(Component of NIC) 7440-02-0 2 08 0
Phenol 108-95-2 1449 08 0
Polycyclic Organic Matter
(Inc PAH, dioxins, etc. NC POM 116 08 0
& AP 42 historic
amorphous glob)
Propionaldehyde 123-38-6 566 08 0
Toluene 108-88-3 16 08 0
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) 3201
or Emission Source Group ID
Z. Emission Source Description : One "Wellons" unit operating as a: a)wood suspension dust-fired burner
(40 million Btu per hour maximum rated heat input); or a b) natural gas-
fired burner(21.8 million Btu per hour maximum rated
3. Operating Scenario ID/ OS - 36/Wellons Bypass for PB process
Description:
4. SCC Number/Description: 30704002/Wood Bulk Handling and Storage- Wood/Bark ; Stockpiles
5. Throughput/units in 2019: 13.8 E6FT3S/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP) Information: (Sources vented to more than one EPP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate(Acrm)
Rectangle(L x W)
(in 0.1 feet)
3235 VERTICAL 50 3.6 950 36.8 22474.7 ERP for Wellons
STACK Bypass
Operating Scenario: OS - 36 Emission Source/Group ID: 3201
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 3 ) Days per Week ( 1 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG GHG Estimation Emission Ef
Pollutants CAS Efficiency
Pollutants Method Code after Factor Control
.(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019 -
CIO CO, .0.58 08
NOx NOx 0.69 08
TSP TSP 0.05 08
PM10 PM10 0.05 - 08
PM2.5 PM2.5 0.05 08
S02- S02 0 08
VOC VOC 0.04 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Arsenic Unlisted
Compounds ( Specify & ASC-Other 0.00277 08
Component of ASC)
Benzene 71-43-2 0.02904 08
Cadmium Metal
(elemental unreacted, 7440-43-9 0.01521 08
Component of CDC)
Chromium Unlisted CRC-
Compounds (Specify & 0.00194 08
Component of CRC) Other
Cobalt Unlisted
Compound (Specify& COC- 0.00116 08
Component of COC) . Other
Formaldehyde 50-00-0 1.03703 08
Manganese Unlisted
Compounds (Specify & MNC_
0.00525 08
Mercury,vapor 7439-97-6 0.0036 08
(Component of HGC)
Naphthalene (Component 91-20-3 0.00843 08
of POMTV)
Nickel metal (Component 7440-02-0 0.02904 08
of NIC)
Toluene 108-88-3 0.04701 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AFRO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) 3501
or Emission Source Group ID
2. Emission Source Description : Sawdust Rock and Metal Separator [BACT]
3. Operating Scenario ID/ OS -21/Rock and metal separator sawdust cleaning system
Description:
4. SCC Number/Description: 30704003/Wood Bulk Handling and Storage- Wood/Bark; Unloading
5. Throughput/units in 2019: 67362 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-29 CD-SC High efficiency cyclone - 72 inches in diameter
2 CS-29 CD-3501 Reverse flow bag filter with 2,410 square feet of surface area
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate Acfm
Rectangle(L x W) ( )
(in 0.1 feet)
ERP for
4003 VERTICAL 45 4 68 21.1 15909.02 Rock/Metal
STACK separator PB
process
Operating Scenario: OS -21 Emission Source/Group ID: 3501
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 . 0
TSP TSP 0.04 04 , 99.96
PM10 PM10 0.04 04 99.96
PM2.5 PM2.5 0.04 04 0
S02 S02 .08. 0
VOC VOC 15.12 08 0,
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 5040-0 65.66278 04 0 AFTER
Methanol 67-56-1 1077.797 04 0 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory- Calendar Year 2019
1.Emission Source ID (from permit) 3515
or Emission Source Group ID
Z. Emission Source Description : Surface Material Transport(SL fines from screening operation) [PSD,
MACT Subpart DDDD]
3. Operating Scenario ID/ OS -22/17ines transport systems
Description:
4. SCC Number/Description: 30704005/Wood Bulk Handling and Storage -Wood/Bark ; Conveyors
5. Throughput/units in 2019: 100715 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-35 CD-3500 Simple cyclone - 72 inches in diameter
2 CS-35 3412 Simple cyclone
3 CS-35 CD-3512B Simple cyclone - 72 inches in diameter
4 CS-35 CD-3515 Reverse flow fabric filter with 5,767 square feet of surface area
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x Vl�
(in 0.1 feet)
VERTICAL ERP for fines
3515 STACK 58.3 5 68 33.3 39230.63 transport PB
process
Operating Scenario: OS -22 Emission Source/Group ID: 3515
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar xYear 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec March-May o June-Aug. o Sept.-Nov. o2019 V25% 2019 25/0 2019 25/0 2019 25/o
13. Actual Emissions ner Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.02 08 99
PM10 PM10 0.02 08 99
PM2.5 PM2.5 0.02 08 99
S02 S02 08 0 .
VOC VOC 59.3 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Code Efficiency Factor Control
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 113.89 08 AFTER
Methanol 67-56-1 1611.437 08 0 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) 3525
or Emission Source Group ID
2. Emission Source Description : Surface Formers and Mat Dumps [BACT]
3. Operating Scenario ID/ OS - 23/Wet(green)material transport systems
Description:
4. SCC Number/Description: 30704005/Wood Bulk Handling and Storage - Wood/Bark ; Conveyors
5. Throughput/units in 2019: 5422 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash" Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-14 CD-3520A Simple cyclone - 96 inches in diameter
2 CS-14 CD-3520B Simple cyclone- 96 inches in diameter
3 CS-14 CD-3521 Simple cyclone- 96 inches in diameter
4 CS-14 CD-3525 Reverse flow fabric filter with 6,918 square feet of surface area
�.Emission Release Point(ERP)Information: (Sources vented to more than one EPP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate (Aefm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL ERP for wet
3525 STACK 10 1 72 10 471.23 material trransport
PB
Operating Scenario: OS -23 Emission Source/Group ID: 3525
10. Operating Sch'edule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec ° March-May ° June-Aug. , ° Sept.-Nov. 25%
2019 25 O 2019 25/0 2019 25%O 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.02 08 99.9
PM10 PM10 0.02 08 99.9
PM2.5 PM2.5 0.02 08 0
S02 S02 08 0
VOC VOC 0.83 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Code Efficiency ) Factor Control
(Pounds/Year) (Net after all controls
(See Instructions)
2019
Formaldehyde 50-00-0 254.8266 08 0 AFTER
Methanol 67-56-1 .49.33877 08 0 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) 3535
or Emission Source Group ID
Z. Emission Source Description : Flying Cut Off Saw, Pretrim Saws, &Production Collection [BACT]
3. Operating Scenario ID/ OS - 24/Dry material transport systems
Description:
4. SCC Number/Description: 30704005/Wood Bulk Handling and Storage- Wood/Bark ; Conveyors
5. Throughput/units in 2019: 14458 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-15 CD-3530 Simple cyclone - 84 inches in diameter
2 CS-15 CD-3531 Simple cyclone - 108 inches in diameter
3 CS-15 CD-3533 Simple cyclone- 108 inches in diameter
4 CS-15 CD-3535 Reverse flow fabric filter with 6,918 square feet of filter area
�. Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL ERP for dry
3535 STACK 53.3 5 68 34.1 40173.11 material transport
PB
Operating Scenario: OS -24 Emission Source/Group ID: 3535
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25o�a Sept.-Nov. —
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.02 08 99.96
PM10 PM10 0.02 08 99.96
PM2.5 PM2.5 0.02 08 0
S02 S02 08 0
VOC VOC 6.41 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 319.2755 04 0 AFTER
Methanol 67-56-1 131.57 08 0
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) 3545
or Emission Source Group ID
2. Emission Source Description : Particleboard Mill Steinemann Finishing Sander [BACT]
3. Operating Scenario ID/ OS - 25/Steinmann sander for PB process
Description:
4. SCC Number/Description: 30703099/Furniture & Wood Working Operations -Miscellaneous ;
Sanding/Planning Operations: Specify
5. Throughput/units in 2019: 21852 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-30 CD-5001 Reverse flow fabric filter with 6,918 square feet of surface area
a. Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
3565 VERTICAL 53.3 5 68 32.1 37816.92 ERP for Steinmann
STACK Sander PB
Operating Scenario: OS -25 Emission Source/Group ID: 3545
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission , Control
GHG GHG Estimation Emission Ef
CAS Efficiency Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Emissions- Emission
Criteria pollutant Control Emission Ef
(NAAQS) Criteria Estimation Efficiency
Pollutants
Code pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.02 08 99.99
PM10 PM10 0.02 08 99.99
PM2.5 PM2.5 0.02 08 0
S02 S02 08 0
VOC VOC 2.98 08 0
HAP/TAP CAS Emissions E Emission Estimation Control Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 832.1436 04 0 AFTER
Methanol 67-56-1 198.8502 04 0 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) 3555
or Emission Source Group ID
2. Emission Source Description : Schelling Saw Board Trim [BACT]
3. Operating Scenario ID/ OS -27/Board trim and transfer system
Description:
4. SCC Number/Description: 30700805/Sawmill Operations ; Planning/Trimming: Cyclone Exhaust
5. Throughput/units in 2019: 35817 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-18 CD-3522 High efficiency cyclone - 120 inches in diameter
2 CS-18 CD-4005 Reverse flow bag filter with 6,918 square feet of surface area
�. Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL ERP for board trim
3555 STACK 54.2 5 68 17.5 20616.7 and transfer system
PB
Operating Scenario: OS -27 Emission Source/Group ID: 3555
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
l3. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG Emission Ef
CAS GHG Estimation Efficiency
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.01 08 99.99
PM10 PM10 0.01 08 99.99
PM2.5 PM2.5 0.01 08 0
S02 S02 - 08 0
VOC VOC 2.51 08 0
Emission
HAP/TAP CAS Emissions Estimation Control Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Mod Cd Efficiency Factor Control
o oe
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 72.96995 04 0 AFTER
Methanol 67-56-1 325.9349 08 0 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AFRO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory- Calendar Year 2019
1. Emission Source ID(from permit) 3565
or Emission Source Group ID
2. Emission Source Description : Particleboard Mill Steinemann Calibrating Sander [BACT]
3. Operating Scenario ID/ OS - 26/PB sanderdust transport for sander
Description:
4. SCC Number/Description: 30704005/Wood Bulk Handling and Storage -Wood/Bark ; Conveyors
5. Throughput/units in 2019: 6572 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency 100
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-31 CD-2006 Reverse flow bag filter with 6,918 square feet of surface area
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm)
Rectangle(L x Vl�
(in 0.1 feet)
VERTICAL ERP for PB
3545 STACK 54 5 68 35.8 42175.88 sanderdust
transport
Operating Scenario: OS - 26 Emission Source/Group ID: 3565
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept,-Nov. 25%
2019 1 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 1.97 08 99.96
PM10 PM10 1.97 08 99.96
PM2.5 PM2.5 1.97 08 0
S02 S02 08 0
VOC VOC 1.16 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 273.6717 04 0 AFTER
Methanol 67-56-1 59.80457 04 0 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory- Calendar Year 2019
1.Emission Source ID(from permit) 3575
or Emission Source Group ID
Z. Emission Source Description : Sander Filter Transport for Filters 3545 & 3565 [BACT]
3. Operating Scenario ID/ OS -28/Sanderdust silo transport system
Description:
4. SCC Number/Description: 30704001/Wood Bulk Handling and Storage -Wood/Bark ; Storage Bins
5. Throughput/units in 2019: 8872 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash I Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-17 3540B Cyclone
2 CS-17 CD-3575 Reverse flow bag filter with 1,159 square feet of surface area
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL ERP for sanderdust
3575 STACK 34 2 68 36.1 6804.68 silo transport PB
Operating Scenario: OS -28 Emission Source/Group ID: 3575
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End- , 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dee 250, March-May 25% 25%25% Sept.-Nov.40 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG GHG Estimation Emission Ef
CAS Efficiency
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
20.19
Emissions- Emission
Criteria Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 1.77 '08 99.9
PM10 PM10 1.77 08 99.9
PM2.5 PM2.5 1.77 08' 0
S02 S02 08 0
VOC VOC 1.57 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 372.6285 04 0 AFTER
Methanol 67-56-1 80.73616 04 0 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AFRO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) 3577
or Emission Source Group ID
2. Emission Source Description : Dry waste tranport system [BACT]
3. Operating Scenario ID/ OS - 35/Dry waste hammermill tranport system
Description:
4. SCC Number/Description: 30704005/Wood Bulk Handling and Storage -Wood/Bark ; Conveyors
5. Throughput/units in 2019: 49947 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-19 CD-3532 Simple cyclone- 60 inches in diameter
2. CS-19 CD-3577 Reverse flow bag filter with 4,068 square feet of surface area
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/see) Rate (Acrm)
Rectangle(L x V1�
(in 0.1 feet)
VERTICAL ERP for dry waste
3577 STACK 53 11.5 68 194 1209034.07 hammermill
transport
Operating Scenario: OS - 35 Emission Source/Group ID: 3577
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
t1.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG GHG Estimation Emission Ef
Pollutants CAS Efficiency
Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO, CO 08 0
NOx, NOx 08 0
TSP TSP 0.05 08 99
PM10 PM10 0.05 08 0
PM2.5 PM2.5 0.05 08 0
S02 S02 08 0
VOC VOC 27.06 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 1098.827 04 0 AFTER
Methanol 67-56-1 799.1467 04 0 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) 3585
or Emission Source Group ID
2. Emission Source Description : PZKR Green Chip Flakers [BACT]
3. Operating Scenario ID/ OS - 29/171aker exhaust system
Description:
4. SCC Number/Description: 30704005/Wood Bulk Handling and Storage- Wood/Bark ; Conveyors
5. Throughput/units in 2019: 96936 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used) .
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-32 CD-3585 Reverse flow bag filter with 4,880 square feet of surface area
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
3585 VERTICAL 41 5 68 18.9 22266.03 ERP for flaker
STACK exhaust system PB
Operating Scenario: OS -29 Emission Source/Group ID: 3585
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 1 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 9.69 08 99.99
PM10 PM10 9.69 08 99.99
PM2.5 PM2.5 9.69 08 0
S02 S02 08 0
VOC VOC 8.51 08 0
Emissions Emission Control
HAP/TAP. CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 132.8023 04 0 AFTER
Methanol 67-56-1 882.1174 04 0 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) 3593
or Emission Source Group ID
Z. Emission Source Description : Short Cycle Laminating Press
3. Operating Scenario ID/ OS - 43/Wemhoner- Short cycle laminating press designed to laminate
Description: MDF and/or Particleboard with overlay
4. SCC Number/Description: 30700799/Plywood Operations ; Other Not Classified
5. Throughput/units in 2019:
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-36 CD-3593 Reverse flow bagfilter(Maximum air-to-cloth ratio of 4.1
ACFM/total filter surface area).
1.Emission Release Point(ERP)Information: (Sources vented to more than one EPP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL ERP for
3593 STACK 20 2.4 68 36.84 10000 Laminating Press/
Bagfilter
Operating Scenario: OS -43 Emission Source/Group ID: 3593
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 1 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG Emission Ef
CAS GHG Estimation Efficiency
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See hnstructions) all controls)
2019
CO CO 08
NOx NOx 08
TSP TSP 08
PM10 PM10 08
PM2.5 PM2.5 08
S02 S02 08
VOC VOC 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants(In Alphabetical Order) (see instructions) HAP/TAPS thd C Efficiency Factor Control
(Pounds/Year) Meoode (Net after all controls)
(See Instructions)
2019
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) 3594
or Emission Source Group ID
2. Emission Source Description : Short Cycle Laminating Press
3. Operating Scenario ID/ OS -48/Short Cycle Laminating press designed to laminate MDF and/or
Description: Particleboard with overlay
4. SCC Number/Description: 30700799/Plywood Operations ; Other Not Classified
5. Throughput/units in 2019:
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-36 CD-3593 Reverse flow bagfilter(Maximum air-to-cloth ratio of 4.1
ACFM/total filter surface area).
�.Emission Release Point(ERP)Information: (Sources vented to more than one EU use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL ERP for
3593 STACK 20 2.4 68 36.84 10000 Laminating Press/
Bagfilter
Operating Scenario: OS -48 Emission Source/Group ID: 3594
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25%o June-Aug. 25% Sept.-Nov. 25%
2019 2019 1 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- . Emission Control
.GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(TonsNear) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(TonsNear) (See Instructions) all controls)
2019
CO CO 08
NOx NOx 08-
TSP TSP 08
PM10 PM10 08
PM2.5 PM2.5 08
S02 S02 08
VOC VOC 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Mthod Code Efficiency Factor Control
e
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) 3595
or Emission Source Group ID
2. Emission Source Description : Surface Hammermill and Surface PZKR's
3. Operating Scenario ID/ OS - 30/Dry material SL mill transport
Description:
4. SCC Number/Description: 30704005/Wood Bulk Handling and Storage -Wood/Bark ; Conveyors
5. Throughput/units in 2019: 6572 TON/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-16 CD-3595 Reverse flow bagfilter (Maximum air-to-cloth ratio of 3.0
ACFM/total filter surface area).
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feettsec) Rate Acfm
Rectangle(L x W) ( )
(in 0.1 feet)
VERTICAL ERP for dry
3595 STACK 44 11.5 68 4 24928.53 material SL mill
transport PB
Operating Scenario: OS - 30 Emission Source/Group ID: 3595
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec ° March-May ° June-Aug. ° Sept.-Nov. °
2019 25/0 2019 25/° 2019 25/O 2019 25/°
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG Emission Ef
CAS GHG Estimation Efficiency
Pollutants Pollutants Method Code civet after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.01 08 99.96
PM10 PM10 0.01 08 99.96
PM2.5 PM2.5 0.01 08 0
S02 S02 08 0
VOC VOC 0.59 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 13.39 04 0 AFTER
Methanol 67-56-1 105.15 04 0 AFTER
COPY Of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) DEF-2010
or Emission Source Group ID
2. Emission Source Description : Particleboard Press [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 4/Particleboard press
Description:
4. SCC Number/Description: 3070065I/Particleboard Manufacture ; Batch Hot Press,Urea Formaldehyde
Resin
5. Throughput/units in 2019: 138792 E3FT2/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information:None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one EPP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
2010 VERTICAL 114 12 72 10 67858.4 ERP for PB press
STACK
Operating Scenario: OS -4 Emission Source/Group ID: DEF-2010
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dee 25% March-May 25% June-Aug. 250�o ISept.-Nov. 25%
2019 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation 'Efficiency
Emission Ef
Pollutants Pollutants Method Code civet after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 0.12 08
NOx NOx' 1.21 08
TSP TSP 10.33 08
PM10 PM10 10.33 08
PM2.5 PM2.5 3.57 08
S02 S02 08
VOC VOC 1.88 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Acetaldehyde 75-07-0 634.09 08
Acrolein 107-02-8 140.23 08
Cumene 98-82-8 7.61 08
Formaldehyde 50-00-0 9694.23 08
Methanol 67-56-1 25607.4 08
Methyl ethyl ketone 78-93-3 . 129.08 08
Phenol 108-95-2 1006.01 08
Propionaldehyde 123-38-6 103.65 08
COPS' of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-0.1
or Emission Source Group ID
Z. Emission Source Description : Refiner [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 50/Refiners
Description:
4. SCC Number/Description: 3070.0950/Fiberboard-Medium Density (MDF) Manufacture ; Continuous
Hot Press,OF Resin
5. Throughput/units in 2019: 7357 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ED Control Device Description
(as listed in permit)
1 CS-50 CD02 Venturi scrubber
2 CS-50 CD14 Venturi scrubber
�.Emission Release Point(ERP)Information: (Sources vented to more than one EPP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm)Rectangle(L x W)
(in 0.1 feet)
ES02 VERTICAL 120.01 8.63 171.05 26.25 92128.08 Scrubber No. 1
STACK Discharge Stack
ES 14 VERTICAL 120.01 8.63 171.05 26.24 92128.08 Scrubber No. 2
STACK Discharge Stack
Operating Scenario: OS - 50 Emission Source/Group ID: ES-01
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 251/1. March-May 1 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 1 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0 08 90
PM10 PM10 0 08 90
PM2.5 PM2.5 08 90
S02 S02 08 0
VOC VOC 08 0
Emissions Emission Control
HAP/TAP Emission EF
CAS HAP/TAPS Estimation Efficiency Pollutants (In Alphabetical Order) (see instructions) Method Code y Factor Control
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-01
or Emission Source Group ID
Z. Emission Source Description : Refiner [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 74/Refiner Startup Cyclone
Description:
4. SCC Number/Description: 30700805/Sawmill Operations ; Planning/Trimming: Cyclone Exhaust
5. Throughput/units in 2019: 146 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft lF) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
ES 1 VERTICAL 10 1 72 0.1 4.71 Refiner Abort
STACK Cyclone
Operating Scenario: OS - 74 Emission Source/Group ID: ES-01
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Emissions- Emission
Criteria pollutant Control Emission Ef
(NAAQS) Criteria Estimation Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08
NOx NOx 08
TSP TSP 0.26 08
PM10 PM10 0.26 08
PM2.5 PM2.5 0.26 08
S02 S02 08
VOC VOC 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AFRO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-02-A
or Emission Source Group ID
2. Emission Source Description Energy System consisting of one dry/wet wood/woodwaste-fired burner
(205 million Btu per hour heat input) [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 5l/Wood Burning in Energy Plant
Description:
4. SCC Number/Description: , 10300903/Wood ; Wood-fired Boiler
5. Throughput/units in 2019: 32720 E6BTU/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-42 CD02-A Urea/water injection system
2 CS-42 CD02 Venturi scrubber
3 CS-42 CD14 Venturi scrubber
�.Emission Release Point(ERP) Information: (Sources vented to more than one EPP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate (Acfm)
Rectangle(L x Vl�
(in 0.1 feet)
ES14 VERTICAL 120.01 8.63 171.05 26.24 92128.08 Scrubber No. 2
STACK Discharge Stack
ES02 VERTICAL 120.01 8.63 171.05 26.25 92128.08 Scrubber No. 1
STACK Discharge Stack
Operating Scenario: OS - 51 Emission Source/Group ID: ES-02-A
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 1 2019 2019
13. Actual Emissions per Pollutant Listed :
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 9.82 08 0
NOx NOx 5.4 08 95
TSP TSP 8.18 08 0
PM10 PM10 8.18 08 0
PM2.5 PM2.5 7.03 08 0
S02 S02 6.53 08 0
VOC VOC 933.8 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AFRO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory- Calendar Year 2019
1.Emission Source ID(from permit) ES-02-A
or Emission Source Group ID
Z. Emission Source Description : Energy System consisting of one dry/wet wood/woodwaste-fired burner
(205 million Btu per hour heat input) [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 75/Energy System Bypass Mode (25MMBtu/hr)
Description:
4. SCC Number/Description: 10300903/Wood ; Wood-fired Boiler
5. Throughput/units in 2019: 32720 E6BTU/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feettsec) Rate (Acfm)
Rectangle(L x Vl�
(in 0.1 feet)
ES-02B VERTICAL Energy System Idle
Bypass STACK 20 1 900 100 4712.38 Run
Operating Scenario: OS - 75 Emission Source/Group ID: ES-02-A
l0. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
l2. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 1 25%
2019 1 2019 2019 2019
l3. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Code Pollutants Method Code (Net after Factor Control
Pollutants (Tons/Year) (See Instructions) all controls)
2019
CO CO 9.82 08
NOx NOx 5.4 08
TSP TSP 8.18 08
PM10 PM10 8.18 08
PM2.5 PM2.5 7.03 08
S02 S02 0.41 08
VOC VOC 0.28 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Acetaldehyde 75-07-0 2.172 08
Acrolein 107-02-8 0.562 08
Arsenic Unlisted
Compounds ( Specify & ASC-Other 0.06 08
Component of ASC)
Benzene 71-43-2 7.689 08
Benzo(a)pyrene
(Component of POMTV & 50-32-8 0.085 08
POM7)
Beryllium Compound,
Unlisted (Specify& BEC-Other 0.011 08
Component of BEC)
Cadmium Metal
(elemental unreacted, 744043-9 0.061 08
Component of CDC)
Chlorine 1 7782-50-5 1 25.849 1 08
Chromium Unlisted CRC-
Compounds (Specify& 0.166 08
Component of CRC) Other
Cobalt Unlisted COC-
Compound (Specify& 0.006 08
Component of COC) Other
Ethylene dichloride (1,2- 107-06-2 0.949 08
dichloroethane)
Formaldehyde 50-00-0 28.892 08
Hexachlorodibenzo-p-
dioxin 1,2,3,6,7,8 57653-85-7 0.052 08
(Component of CLDC)
Hydrogen chloride 7647-01-0 51.371 08
(hydrochloric acid)
Manganese Unlisted MNC-
Compounds (Specify& Other 0.857 08
Component of MNC)
Mercury,vapor. 7439-97-6 0.022 08
(Component of HGC)
Methanol 67-56-1 8.669 08
Methyl chloride 74-87-3 . 0.756 08
Methyl ethyl ketone 78-93-3 0.096 08
Methylene chloride 75-09-2 11.452 08
Naphthalene (Component 91-20-3 2.434 08
of POMTV)
Nickel metal(Component of NIC) 7440-02-0 0.129 08
Phenol 108-95-2 0.352 08
Phosphorus Metal,Yellow 7723-14-0 3.223 08
or White
Polycyclic Organic Matter
(Inc PAH, dioxins, etc.NC pOM 4.09 08
&AP 42'historic
amorphous glob)
Propionaldehyde 123-38-6 0.571 08
Toluene 108-88-3 0.766 08
Vinyl chloride 75-01-4 0.602 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Ain Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) ES-02-B
or Emission Source Group ID
2. Emission Source Description : Two Stage Dryer System [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 69/Two Stage Dryer System-Wood Drying
Description:
4. SCC Number/Description: 3 070092 1/Fiberboard-Medium Density (MDF) Manufacture ; Direct Wood-
fired Tube Dryer, Unspecified Pines
5. Throughput/units in 2019: 7503 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-50 CD02 Venturi scrubber
2 CS-50 CD14 Venturi scrubber
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate Acfm
Rectangle(L x W) ( )
(in 0.1 feet)
VERTICAL Scrubber No. 1
ES02 STACK 120.41 8.63 171.05 26.25 92128.08 Discharge Stack
ES 14 VERTICAL 120.01 8.63 171.05 26.24 92128.08 Scrubber No. 2
STACK Discharge Stack
Operating Scenario: OS - 69 Emission Source/Group ID: ES-02-B
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec o March-May o June-Aug. o Sept.-Nov. o
2019 25/0 2019 25/0 2019 25/0 2019 25/o
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 156.75 08 0
NOx NOx 86.21 08 0
TSP TSP 61.14 10 90 AFTER
PM10 PM10 61.14 10 90 AFTER
PM2.5 PM2.5 61.14 10 90 AFTER
S02 S02 6.53 08 0
VOC VOC 933.8 10 90 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Efficiency Factor Control
(Pounds/Year) Code (Net after all controls)
(See Instructions)
2019
Acetaldehyde 75-07-0 5099 08 90 AFTER
Acrolein 107-02-8 110.56 08 0
Cumene 98-82-8 996.28 08 90 AFTER
Formaldehyde 50-00-0 10462.16 08 90 AFTER
Methanol 67-56-1 506732.64 08 90 AFTER
Phenol 108-95-2 16136.27 08 90 AFTER
Propionaldehyde 123-38-6 81.78 08 0
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) ES-02-C-1
or Emission Source Group ID
2. Emission Source Description : Backup natural gas-fired dryer burner(35 million Btu per hour heat
input) [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 86/MDF Backup Natural Gas Dryer Burners (ES-02C and ES-02D)
Description: Combined 87 imnBTU/hr Firing Rate
4. SCC Number/Description: 10200602/Natural Gas ; 10-100 Million Btu/hr
5. Throughput/units in 2019: 45.757 E6FT3S/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-41 CD02 Venturi scrubber
2 CS-41 CD02-A Urea/water injection system
3 CS-41 CD14 Venturi scrubber
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow. ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate (Acfm)
Rectangle(L x W)
(in 0.1 feet)
ES02 VERTICAL 120.01 8.63 171.05' 26.25 92128.08 Scrubber No. 1
STACK Discharge Stack
ES 14 VERTICAL 120.01 8.63 171.05 26.24 92128.08 Scrubber No. 2
STACK Discharge Stack
Operating Scenario: OS - 86 Emission Source/Group ID: ES-02-C-1
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput: _
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 12019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
CO CO 08 0
NOx NOx 08 0
NOx NOx 08 0
TSP TSP 08 98
TSP TSP 0 08 98
PM10 PM10 08 0
PM10 PM10 08 0
PM2.5 PM2.5 08 0
PM2.5 PM2.5 08 0
S02 S02 08 0
S02 S02 08 0
VOC VOC 08 0
VOC VOC 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Efficiency Factor Control
(Pounds/Year) Mod Code (Net after all controls)
(See Instructions)
2019
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) ES-02-C-2
or Emission Source Group ID
Z. Emission Source Description : Backup natural gas-fired dryer burner(35 million Btu per hour heat
input) [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 87/1\4DF Backup Natural Gas Dryer Burners (ES-02C and ES-02D)
Description: Combined 87 mmBTU/hr Firing Rate
4. SCC Number/Description: 10200602/Natural Gas ; 10-100 Million Btu/hr
5. Throughput/units in 2019: 45.757 E6FT3S/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
.3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-41 CD02 Venturi scrubber
2 CS-41 CD02-A Urea/water injection system
3 CS-41 CD14 Venturi scrubber
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate(Acfm)
Rectangle(L x Vl�
(in 0.1 feet)'
ES02 VERTICAL 120.01 8.63 171.05 26.25 92128.08 Scrubber No. 1
STACK Discharge Stack
ES14 VERTICAL 120.01 8.63. 171.05 26.24 92128.08 Scrubber No. 2
STACK Discharge Stack
Operating Scenario: OS - 87 Emission Source/Group ID: ES-02-C-2
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.- .. 25%
2019 1 2019 2019 2019
13.. Actual Emissions uer Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Emissions- Emission Control Criteria
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
CO CO 08 0
NOx NOx 08 0
NOx NOx 08 0
TSP TSP 08 98
TSP TSP 0 08 98
PM10 PM10 08 0
PM10 PM10 08 0
PM2.5 PM2.5 08 0
PM2.5 PM2.5 08 0
S02 S02 08 0
S02 S02 08 0
VOC VOC 08 0
VOC VOC 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) ES-02-D
or Emission Source Group ID
Z. Emission Source Description : MDF Dryer Burners (Natural Gas)
3. Operating Scenario ID/ OS - 88/MDF Backup Natural Gas Dryer Burners (ES-02C and ES-02D)
Description: Combined 87 mmBtu/hr Firing Rate
4. SCC Number/Description: 10200602/Natural Gas ; 10-100 Million Btu/hr
5. Throughput/units in 2019: 114 E6FT3S/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-50 CD02 Venturi scrubber
2 CS-50 CD14 Venturi scrubber
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate(Actm)
Rectangle(L x W)
(in 0.1 feet)
ES02 VERTICAL 120.01 8.63 171.05 26.25 92128.08 Scrubber No. 1
STACK Discharge Stack
ES 14 VERTICAL 120.01 8.63 171.05 26.24 92128.08 Scrubber No. 2
STACK Discharge Stack
Operating Scenario: OS - 88 Emission Source/Group ID: ES-02-D
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start& End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 1 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 1 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Code Pollutants Method Code (Net after Factor Control
Pollutants (Tons/Year) (See Instructions) all controls)
2019
CO CO 4.8 08
NOx NOx 2.86 08
TSP TSP 0.03 08 98
PM10 PM10 0.03 08 98
PM2.5 PM2.5 0.02 08 80
S02 S02 0.03 08
VOC VOC 0.31 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Mthod Code Efficiency Factor Control
e
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
Benzene 7.1-43-2 0.24 08 0
Cobalt Unlisted COC-
Compound (Specify & Other 0.01 08 0
Component of COC)
Formaldehyde 50-00-0 8.58 08 0
Hexane, n- 110-54-3 205.84 08 0
Naphthalene (Component 91-20-3 0.07 08 0
of POMTV)
Toluene 108-88-3 0.39 08 0
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory- Calendar Year 2019
1.Emission Source ID (from permit) ES-03
or Emission Source Group ID
2. Emission Source Description : Fiber Sifter System [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 53/Fiber Sifter System
Description:
4. SCC Number/Description: 30703002/Furniture &Wood Working Operations -Miscellaneous ; Wood
Waste Storage Bin Loadout
5. Throughput/units in 2019: 7022 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-43 CD03 Fabric Filter(12,290 square feet of filter area)
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
ES03 VERTICAL 49.7 8.69 68.09 0.1 355.86 Fiber Sifter Filter
STACK
Operating Scenario: OS - 53 Emission Source/Group ID: ES-03
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
H. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Itstructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 2.04 08 99 AFTER
PM10 PM10 2.04 08 99 AFTER
PM2.5 PM2.5 2.04 08 99 AFTER
S02 S02 08 0
VOC VOC 10.54 08 99 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Cumene 98-82-8 8.76 08 99 AFTER
Formaldehyde 50-00-0 2133.78 08 99 AFTER
Methanol 67-56-1 1654.28 08 99 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory- Calendar Year 2019
1.Emission Source ID (from permit) ES-04
or Emission Source Group ID
Z. Emission Source Description : Forming Line Clean-Up System [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 54/Forming Line Clean-Up System
Description:
4. SCC Number/Description: 3 0703 002/Furniture &Wood Working Operations -Miscellaneous ; Wood
Waste Storage Bin Loadout
5. Throughput/units in 2019:, 7022 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-44 CD04 Fabric Filter(9,346 square feet of filter area)
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL Forming Line
ESO4 STACK 56.1 9.42 68.09 0.1 418.16 Cleanup Filter
Operating Scenario: OS - 54 Emission Source/Group ID: ES-04
l0.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day. ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
t1. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants
Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 1.93 08 99 AFTER
PM10 PM10 1.93 08 99 AFTER
PM2.5 PM2.5 1.93 08 99 AFTER
S02 S02 08 0
VOC VOC 10.54 08 99 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Cumene 98-82-8 8.76 08 99 AFTER
Formaldehyde 50-00-0 2133.78 08 99 AFTER
Methanol 67-56-1 1654.28 08 99 AFTER
COPY of'RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-05
or Emission Source Group ID
Z. Emission Source Description : Mat Reject System [PSD,MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 55/Mat Reject System
Description:
4. SCC Number/Description: 30703002/Furniture & Wood Working Operations -Miscellaneous ; Wood
Waste Storage Bin Loadout
5. Throughput/units in 2019: 395 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-45 CD05 Fabric Filter(9,346 square feet of filter area)
�. Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft /F) (Feet/sec) Rate (Acfm)
Rectangle(L x W) ll
(in 0.1 feet)
ES05 VERTICAL 56 9.42 68.09 0.1 418.16 Mat Reject System
STACK Filter
Operating Scenario: OS - 55 Emission Source/Group ID: ES-05
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG GHG Estimation Emission Ef
CAS Efficiency Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants
Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.09 08 99 AFTER
PM10 PM10 0.09 ' 08 99 AFTER
PM2.5 PM2.5 0.09 08 99 AFTER
S02 S02 08 0
VOC VOC 0.61 08 99 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Cumene 98-82-8 0.56 08 0
Formaldehyde 50-00-0 122.9 08 99 AFTER
Methanol 67-56-1 95.28 08 99 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) ES-06-B.
or Emission Source Group ID
2. Emission Source Description : MDF Board Cooler and Press Hall [PSD,MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 56/MDF Board Cooler
Description:
4. SCC Number/Description: 30700971/Fiberboard-Medium Density (MDF) Manufacture ; MDF Board
Cooler,OF Resin
5. Throughput/units in 2019: 114 E3FT2/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-50 CD02 Venturi scrubber
2 CS-50 CD14 Venturi scrubber
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
ES02 VERTICAL 120.01 8.63 171.05 26.25 92128.08 Scrubber No. 1
STACK Discharge Stack
ES 14 VERTICAL 120.01 8.63 171.05 26.24 92128.08 Scrubber No. 2
STACK Discharge Stack
Operating Scenario: OS - 56 Emission Source/Group ID: ES-06-B
l0.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
ll.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 1 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 1 12019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Emission Ef
(NAAQS) Criteria Estimation Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08' 0
TSP TSP 08 90
PM10 PM10 0 08 90
PM2.5 PM2.5 08 90
S02 S02 08 0
VOC VOC ' 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Code Efficiency Factor Control
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
COPY ofRECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) ES-07
or Emission Source Group ID
2. Emission Source Description : Saw System [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 57/Saw System Filter
Description:
4. SCC Number/Description: 30700898/Sawmill Operations ; Other Not Classified
5. Throughput/units in 2019: 7022 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-46 CD07 Fabric Filter(6,793 square feet of filter area)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft ' (F) (Feet/sec) Rate (Acfm)
Rectangle(L x V1)
(in 0.1 feet)
ES07 VERTICAL STACK 56.5 10.27 68.09 0.1 497.02 Saw System Filter
Operating Scenario: OS - 57 Emission Source/Group ID: ES-07
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 1 25%
2019 1 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 2.95 08 99 AFTER
PM10 PM10 2.95 08 99 AFTER
PM2.5 PM2.5 2.95 08 99 AFTER
S02 S02 08 0
VOC VOC 0.85 08' 99 AFTER
Emission
HAP/TAP CAS Emissions Estimation Control Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Code Efficiency Factor Control
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 102.07 08 0
Methanol 67-56-1 1417.62 08 99 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) ES-08
or Emission Source Group ID
2. Emission Source Description : Sander System No.1 [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 58/Sander System No.1 Exhaust Filter
Description:
4. SCC Number/Description: 30700702/Plywood Operations ; Sanding Operations
5. Throughput/units in 2019: 7022 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-47 CD08 Fabric Filter(12,290 square feet of filter area)
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): lF) (Feet/sec) Rate (Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL Sander Exhaust
ES-08 STACK 51.71 " 4.27 68.09 82.91 71236.7 Fan
Operating.Scenario: OS - 58 Emission Source/Group ID: ES-08
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11. Typical Start& End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG GHG Estimation Emission Ef
Pollutants CAS Efficiency
Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 3.16 08 99 AFTER
PM10 PM10 3.16 08 99 AFTER
PM2.5 PM2.5 3.16 08 99 AFTER
S02 S02 08 0
VOC VOC 0.84 08 99 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 60.58 08 99 AFTER
Methanol 67-56-1 340.23 08 99 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-09
or Emission Source Group ID
Z. Emission Source Description : Recycled Fiber Silo No.I [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 59/Recycled Fiber Silo No. 1 Filter
Description:
4. SCC Number/Description: 30704004/Wood Bulk Handling and Storage- Wood/Bark ; Loading
5. Throughput/units in 2019: 395 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3.Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-48 CD09 Bin Vent Filter(226 square feet of filter area)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate (Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL Reject Fiber Silo
ES09 STACK 84.51 1.08 68.09 0.1 5.49 No. 1 Filter
Operating Scenario: OS - 59 Emission Source/Group ID: ES-09
[0. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 1 25% June-Aug. 250% Sept.-Nov. 25%
2019 1 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0 08 99 AFTER
PM10 PM10 0 08 99 AFTER
PM2.5 PM2.5 0 08 99 AFTER
S02 S02 08 0
VOC VOC 0.55 08 99 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Code Efficiency Factor Control
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 112.19 08 99 AFTER
Methanol 67-56-1 86.98 08 99 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-10
or Emission Source Group ID
2. Emission Source Description : Sander System No. 2 [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 60/Sander System No. 2 Exhaust Filter
Description:
4. SCC Number/Description: 30700702/Plywood Operations ; Sanding Operations
5. Throughput/units in 2019: 7022 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-49 CD10 Fabric Filter(12,290 square feet of filter area)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/see) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
ES 10 VERTICAL 51.71 4.27 68.09 82.32 70729.76 Finish Sander and
STACK Panel Sawing Filter
Operating Scenario: OS - 60 Emission Source/Group ID: ES-10
M Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 12011. 2019 12019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG Emission Ef
CAS GHG Estimation Efficiency
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 1.58 08 99 AFTER
PM10 PM10 1.58 08 99 AFTER
PM2.5 PM2.5 1.58 08 99 AFTER
S02 S02 08 0
VOC VOC 0.84 08 99 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 60.58 08 99 AFTER
Methanol 67-56-1 272.61 08 99 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AFRO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-12
or Emission Source Group ID
2. Emission Source Description : Sander Dust Silo No. 1 [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 61/Sander Dust Silo No. 1 Filter
Description:
4. SCC Number/Description: 30700807/Sawmill Operations ; Sanderdust: Cyclone Exhaust
5. Throughput/units in 2019: 3511 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-52 CD12 Bin Vent Filter(226 square feet of filter area)
a.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate (Acfm)
Rectangle(L x W)
(in 0.1 feet)
ES 12 VERTICAL 87.99 1.08 68.09 0.1 5.49 Sander Dust Silo
STACK No. 1 Filter
Operating Scenario: OS - 61 Emission Source/Group ID: ES-12
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.04 08 99 AFTER
PM10 PM10 0.04 08 99 AFTER
PM2.5 PM2.5 0.04 08 99 AFTER
S02 S02 08 0
VOC VOC 0.05 08 99 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 3.36 08 99 AFTER
Methanol 67-56-1 15.1 08 99 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-13
or Emission Source Group ID
1. Emission Source Description : Dry Sawdust Silo [PSD,MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 62/Dry Sawdust Silo Filter
Description:
4. SCC Number/Description: 30700803/Sawmill Operations ; Sawdust Pile Handling
5. Throughput/units in 2019: 7022 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-53 CD13 Bin Vent Filter(226 square feet of filter area)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL Sawdust and Reject
ES 13 STACK 89.99 1.08 68.09 0.1 5.49 Fiber Silo Filter
Operating Scenario: OS - 62 Emission Source/Group ID: ES-13
l0. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
H.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency, Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Emission Ef
(NAAQS) Criteria Estimation Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.07 08 99 AFTER
PM10 PM10 0.07 08 99 AFTER
P_M2.5 PM2.5 0.07 08 99 AFTER
S02 S02 08 0
VOC VOC 0.06 08 99 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Mthod Code Efficiency Factor Control
e
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
Methanol 67-56-1 4.8 08 99 AFTER
Phenol 108-95-2 21.58 08 0
COPY of RECORD .Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: .Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) ES-15
or Emission Source Group ID
Z. Emission Source Description : Recycled Fiber Silo No. 2 [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 63/Reject Fiber Silo No. 2 Filter
Description:
4. SCC Number/Description: 30703002/Furniture &Wood Working Operations -Miscellaneous ; Wood
Waste Storage Bin Loadout
5. Throughput/units in 2019: 395 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-54 CD15 Bin Vent Filter(226 square feet of filter area)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL Reject Fiber Silo
ES 15 STACK 84.51 1.08 68.09 0.1 5.49 No. 2 Filter
Operating Scenario: OS - 63 Emission Source/Group ID: ES-15
t0. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Code Pollutants Method Code (Net after Factor Control
Pollutants Tons/Year all controls
( ) (See Instructions) )
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 08 0
PM10 PM10 08 0
PM2.5 PM2.5 08 0
S02 S02 08 0
VOC VOC 0.55 08 99
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 112.19 08 99
Methanol 67-56-1 86.98 08 99
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-16
or Emission Source Group ID
2. Emission Source Description : MDF Press [PSD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 49/Scrubber controlling press
Description:
4. SCC Number/Description: 30700950/Fiberboard-Medium Density(MDF) Manufacture ; Continuous
Hot Press,OF Resin
5. Throughput/units in 2019: 151449 E3FT2/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-50 CD02 Venturi scrubber
2 CS-50 CD14 Venturi scrubber
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/see) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
ES02 VERTICAL 120.01 8.63 171.05 26.25 92128.08 Scrubber No. I
STACK Discharge Stack
ES 14 VERTICAL 120.01 8.63 171.05 26.24 92128.08 Scrubber No. 2
STACK Discharge Stack
Operating Scenario: OS -49 Emission Source/Group ID: ES-16
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 12019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOX NOX 08 0
TSP TSP 0 08 90
PM10 PM10 08 90
PM2.5 PM2.5 08 90
S02 S02 08 0
VOC VOC 08 0
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Code Effift aciency ) Factor Control
(Pounds/Year) et er all controls
(See Instructions)
2019
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) ES-17
or Emission Source Group ID
Z. Emission Source Description : Sander Dust Silo No. 2 [P.SD, MACT Subpart DDDD]
3. Operating Scenario ID/ OS - 64/Sander Dust Silo No. 2 Filter
Description:
4. SCC Number/Description: 30700807/Sawmill Operations ; Sanderdust: Cyclone Exhaust
5. Throughput/units in 2019: 3511 HR/yr
(e.g.production or fuel use):
6. Fuel Information %aSulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented 100
to Control Device or Stack):
3. Control Device Information
Order CS-ID CD ID Control Device Description
(as listed in permit)
1 CS-55 CD 17 Bin Vent Filter(226 square feet of filter area)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate (ncfm)
Rectangle(L x W)
(in 0.1 feet)
VERTICAL Sander Dust Silo
ES 17 STACK 87.99 1.08 68.09 0.1 5.49 No. 2 Filter
Operating Scenario: OS - 64 Emission Source/Group ID: ES-17
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 250% March-May 1 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Emission Ef
(NAAQS) Criteria Estimation Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08 0
NOx NOx 08 0
TSP TSP 0.04 08 99 AFTER
PM10 PM10 0.04 08 99 AFTER
PM2.5 PM2.5 0.04 08 99 AFTER
S02 S02 08 0
VOC VOC 0.05 08 99 AFTER
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 3.36 08 99 AFTER
Methanol 67-56-1 15.1 08 99 AFTER
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) ES-21
or Emission Source Group ID
2. Emission Source Description : Diesel Fuel-fired Emergency Generator(1592 Brake Horsepower output)
[PSD, MACT ZZZZ]
3. Operating Scenario ID/ OS - 80/MDF Emergency Generator Operation
Description:
4. SCC Number/Description: MOW ; Diesel
5. Throughput/units in 2019: 14 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
l
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft lF) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
MDF - VERTICAL ERP for MDF
EDG STACK 12.5 3.8 895 254.7 173315.44 Diesel Emergency
Generator
Operating Scenario: OS - 80 Emission Source/Group ID: ES-21
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 250/. March-May 1
25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
(NAAQS) Pollutant Criteria Estimation Efficiency Emission Ef
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 0.07 08
NOx NOx 0.35 08
TSP TSP 0.02 08
PM10 PM10 0.02 08
PM2.5 PM2.5 0.02 08
S02 S02 0.02 08
VOC VOC 0.03 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Acetaldehyde 75-07-0 0.00393 08
Acrolein 107-02-8 0.00123 08
Arsenic Unlisted
Compounds ( Specify& ASC-Other 0.00062 08
Component of ASC)
Benzene 71-43-2 0.121 08
Benzo(a)pyrene
(Component of POMTV & 50-32-8 0.00004 08
POM7)
Beryllium metal
(unreacted) (Component 7440-41-7 0.00047 08
of BEC)
Cadmium Metal
(elemental unreacted, 7440-43-9 0.00047 08
Component of CDC)
Chromic acid (VI)
Formaldehyde 50-00-0 0.0123 08
Manganese Unlisted MNC-
Compounds (Specify & Other 0.00094 08
Component of MNC)
Mercury,vapor 7439-97-6 0.00047 08
(Component of HGC)
Nickel metal(Component 7440-02-0 0.00047 08
of NIC)
Toluene 108-88-3 0.0438 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) EVAP-1.19C
or Emission Source Group ID
2. Emission Source Description : Wastewater evaporator [MACT DDDD]
3. Operating Scenario ID/ OS 85/Wastewater evaporator
Description:
4. SCC Number/Description: 40282599/Wastewater, Points of Generation ; Specify Point of Generation
5. Throughput/units in 2019:
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
EVAP-1 FUGITIVE (NO 1 72 Area= 1 Wastewater
STACK) Evaporator
Operating Scenario: OS - 85 Emission Source/Group ID: EVAP-
1.19C
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 1 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef-
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
.2019
CO CO 08
NOx NOx 08
TSP TSP 08
PM10 PM10 08
PM2.5 PM2.5 08
S02 S02 08
VOC VOC 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
COPY Of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) I-DFP-1
or Emission Source Group ID
2. Emission Source Description : Diesel Fuel-fired Fire Pump Engine (347 Brake Horsepower output)
[MACT ZZZZ,NSPS IIII]
3. Operating Scenario ID/ OS - 76/Diesel-fired fire pump engine operation
Description:
4. SCC Number/Description: 203 0010 1/Distillate Oil (Diesel) ; Reciprocating
5. Throughput/units in 2019: 31.6 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
a.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry, lines):
ERP ID ERP Type Height Diameter Temperature , Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
ESDFPI VERTICAL 16 0.417 1076 231.74 1899 Diesel-fired Fire
STACK Pump Stack
Operating Scenario: OS - 76 Emission Source/Group ID: I-DFP-1
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions uer Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG Emission Ef
CAS GHG Estimation Efficiency
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 0.04 08
NOx NOx 0.17 08
TSP TSP 0.01 08
PM10 PM10 0.01 08
PM2.5 PM2.5 0.01 08
S02 S02 0.01 08
VOC VOC 0.01 08
Emissions' Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Acetaldehyde 75-07-0 0.06 08
Acrolein 107-02-8 0.01 08
Benzene 7143-2 0.07 08
Formaldehyde 50-00-0 0.09 08
Naphthalene (Component 91-20-3 0.01 08
of POMTV)
Polycyclic Organic Matter
(Inc PAH, dioxins, etc. NC POM 0.01 08
& AP 42 historic
amorphous glob)
Toluene 108-88-3 0.03 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) I-GAS
or Emission Source Group ID
2. Emission Source Description : One 500 gallons above ground gasoline storage tank
3. Operating Scenario ID/ OS -41/DOUBLE WALLED STORAGE TANK
Description:
4. SCC Number/Description: 39090012/Fuel Storage -Fixed Roof Tanks ; Dual Fuel (Gas/Oil): Working
Loss
5. Throughput/units in 2019: 7991 GAL/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuetis used)
(Btu/units)
7. Capture Efficiency
(%,of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
'Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
HORIZONTAL
GAS DOWNWARD- DOUBLE
TANK FACING VENT 5 3.5 70 0.1 57.72 WALLED
GASOLINE
TANK
Operating Scenario: OS -41 Emission Source/Group ID: I-GAS
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ,( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
CAS
GHG GHG Estimation Efficiency
Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all'controls)
2019
CO CO 08
NOx NOx 08
TSP TSP 08
PM10 PM10 08
PM2.5 PM2.5 08
S02 S02 08
VOC VOC 08
Emission
HAP/TAP CAS Emissions . Estimation Control Emission EF
Pollutants (In Alphabetical Order) . (see instructions) HAP/TAPS. Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Benzene 7143-2 0.35 08
Cumene 98-82-8 0.04 08
Hexane, n 110-54-3 0.42 08
Naphthalene (Component 91-20-3 0.09 08
of POMTV)
Toluene 108-88-3 169.64 08
COPS' of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) I-Irrigation fugitiv
or Emission Source Group ID
2. Emission Source Description : Spray Irrigation Field Fugitives
3. Operating Scenario ID/ OS - 82/Fugitives from spray irrigation system
Description:
4. SCC Number/Description: 68282599/Wastewater, Points of Generation ; Specify Point of Generation
5. Throughput/units in 2019: 2.2955 E6GAL/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or.Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/sec) Rate(Aefm)
Rectangle(L x W)
(in 0.1 feet)
FUGITIVE (NO Fugitive emission
Fugitive STACK) 1 70 Area= 1 from ponds and
irrigation fields
Operating Scenario: OS - 82 Emission Source/Group ID: I-Irrigation
fugitiv
L0.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
H.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
U. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 250% March-May 25% 25%25% Sept.-Nov. 25%
2019 2019 20 1 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08
NOx NOx 08
TSP TSP 08
PM10 PM10 08
PM2.5 PM2.5 08
S02 S02 08
VOC VOC 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order)_ (see instructions) HAP/TAPS Mthod CodEfficiency ) Factor Control
e e (N
(Pounds/Year) et after all controls
(See Instructions)
2019
Formaldehyde 50-00-0 3.83 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory- Calendar Year 2019
1.Emission Source ID (from permit) I-LPA
or Emission Source Group ID
Z. Emission Source Description : Log Processing Area
3. Operating Scenario ID/ OS - 81/Never Commissioned
Description:
4. SCC Number/Description: Not required 6y facility, will be completed by DAQ
5. Throughput/units in 2019:
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3.Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information:(Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate (Aefm)
Rectangle(L x W)
(in 0.1 feet)
Operating Scenario: OS - 81 Emission Source/Group ID: I-LPA
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 -) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 250/. March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant i Emission Ef
(NAAQS) ' Criteria Estimation Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08
NOx NOx 08
TSP TSP 08
PM10 PM10 08
PM2.5 PM2.5 08 '
S02 S02 08
VOC VOC 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
COPS' of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point.Source Emissions Inventory- Calendar Year 2019
1.Emission Source ID (from permit) I-ODG
or Emission Source Group ID
1. Emission Source Description : Diesel-fired emergency generator(465 horsepower, 3026 million Btu per
hour heat input)[MACT ZZZZ]
3. Operating Scenario ID/ OS - 7/Diesel-fired emergency generator
Description:
4. SCC Number/Description: 2020.0102/Distillate Oil (Diesel) ; Reciprocating
5. Throughput/units in 2019: 8.8 HR/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate(Acfm)
Rectangle(L x W)
(in 0.1 feet)
ODG HORIZONTAL 12.5 3.8 895 254.7 173315.44 erp for PB diesel
STACK generator
Operating Scenario: OS - 7 Emission Source/Group ID: I-ODG
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
13. Actual Emissions ner Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG Emission Ef
CAS GHG Estimation Efficiency
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) . Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 0 08
NOx NOx 0.02 08
TSP TSP 08
PM10 PM10 08
PM2.5 PM2.5 08
S02 S02 08
VOC VOC 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Efficiency Factor Control
(Pounds/Year) Method Code (Net after all controls)
(See Instructions)
2019
Acetaldehyde 75-07-0 0.01 08
Acrolein 107-02-8 0.00096 08
Benzene 71-43-2 0.01 08
Formaldehyde 50-00-0 0.01 08
Naphthalene (Component 91-20-3 0.00088 08
of POMTV)
Polycyclic Organic Matter
(Inc PAH, dioxins, etc. NC POM 0.00087 08
& AP 42 historic
amorphous glob)
Toluene 108-88-3 0 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID(from permit) I-Wastewater ponds
or Emission Source Group ID
2. Emission Source Description : Fugitives from wastewater lagoons
3. Operating Scenario ID/ OS - 83/Fugitives from wastewater ponds
Description:
4. SCC Number/Description: 68282599/Wastewater, Points of Generation ; Specify Point of Generation
5. Throughput/units in 2019: 2.879 E6GAL/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used).
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one EPP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/sec) Rate (Acfm)
Rectangle(L x W)
(in 0.1 feet)
FUGITIVE (NO Fugitive emission
Fugitive STACK) 1 70 Area= 1 from ponds and
irrigation fields
O Emission Source/Group ID: I-
perating Scenario: OS - 83
Wastewater ponds
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec u March-May u June-Aug. o Sept.-Nov. u
2019 25/0 2019 25/0 2019 25% 2019 25/o
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Emission Ef
(NAAQS) Criteria Estimation Efficiency
Code ode Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08
NOx NOx 08
TSP TSP 08
PM10 PM10 08
PM2.5 PM2.5 08
S02 S02 08
VOC VOC 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Code Efficiency Factor Control
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
Formaldehyde 50-00-0 4.81 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015.
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
1.Emission Source ID (from permit) PB-BC
or Emission Source Group ID
Z. Emission Source Description : Particleboard Cooler [BACT]
3. Operating Scenario ID/ OS - 39/Particle Board Cooler
Description:
4. SCC Number/Description: 30700661/Particleboard Manufacture ; Particleboard Board Cooler,Urea-
Formaldehyde Resin
5. Throughput/units in 2019: 138792 E3FT2/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash' Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%.of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
I.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter ft (F) (Feet/see) Rate Acfm
Rectangle(L x W) ( )
(in 0.1 feet)
FUGITIVE (NO Fugitives from
erp-pbc STACK) 1 72 Area= 1 particleboard
y cooler
Operating Scenario: OS - 39 Emission Source/Group ID: PB-BC
10. Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11. Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 2019 2019 2019
B. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG CAS GHG Estimation Efficiency Emission Ef
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 10.41 08
NOx NOx 08
TSP TSP 15.75 08
PM10 PM10 15.75 08
PM2.5 PM2.5 5.34 08
S02 S02 08
VOC VOC 9.29 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (See instructions) HAP/TAPS Method Code (NEfficiency ) Factor Control
Pounds/Year et after all controls
(See Instructions)
2019
Acetaldehyde 75-07-0 180.43 08
Acrolein 107-02-8 49.97 08
Cumene 98-82-8 7.61 08
Formaldehyde 50-00-0 2747.38 08
Methanol 67-56-1 7484.75. 08
Methyl ethyl ketone 78-93-3 15.27 08
Phenol 108-95-2 652.32' 08
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory- Calendar Year 2019
1.Emission Source ID(from permit) Pr-Heatl
or Emission Source Group ID
2. Emission Source Description : Natural gas or No. 2 fuel oil-fired hot oil heater(4.7 million Btu per hour
heat input)used with short cycle laminating presses [Case-by-Case
MACT]
3. Operating Scenario ID/ OS - 46/Natural gas or No.2 fuel oil-fired oil heater(4.7MMBTU.hr)
Description: used with short cycle laminating presses
4. SCC Number/Description: 10200603/Natural Gas ; < 10 Million Btu/hr
5. Throughput/units in 2019: 0.6 E6FT3S/yr
(e.g.production or fuel use):
6. Fuel Information %Sulfur %Ash Heat Content
(If fuel is used)
(Btu/units)
7. Capture Efficiency
(%of Emissions from this Process Vented
to Control Device or Stack):
3. Control Device Information :None
Order CS-ID CD ID Control Device Description
(as listed in permit)
�.Emission Release Point(ERP)Information: (Sources vented to more than one ERP use additional entry lines):
ERP ID ERP Type Height Diameter Temperature Velocity Volume Flow ERP Description
(in feet) Circle(enter#): (F) (Feet/scc) Rate (Acfm)
Rectangle(L x W)
(in 0.1 feet)
PR- VERTICAL 20 3 68 23.57 10000 ERP for Thermal
HEAT 1 STACK . Heater
Operating Scenario: OS -46 Emission Source/Group ID: Pr-Heatl
10.Operating Schedule:(Source/OperatingScenario that best characterizes Calendar Year 2019)
Hours per Day ( 24 ) Days per Week ( 7 ) Weeks per Year ( 52 )
11.Typical Start&End Times For Operating Scenario: Start: 0 End: 2359
12. Seasonal Periods Percent Annual Throughput:
Jan-Feb +Dec 25% March-May 25% June-Aug. 25% Sept.-Nov. 25%
2019 1 2019 2019 12019
13. Actual Emissions per Pollutant Listed
Attach calculations and documentation of emission factors or other estimation methods used.
Emissions- Emission Control
GHG Emission Ef
CAS GHG Estimation Efficiency
Pollutants Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
Criteria Emissions- Emission Control
Pollutant Criteria Estimation Emission Ef
(NAAQS) Efficiency
Pollutants Code Pollutants Method Code (Net after Factor Control
(Tons/Year) (See Instructions) all controls)
2019
CO CO 08
NOx NOx 0 08
TSP TSP 0 08
PM10 PM10 0 08
PM2.5 PM2.5 0 08
S02 S02 08
VOC VOC 0.03 08
Emissions Emission Control
HAP/TAP CAS Estimation Emission EF
Pollutants (In Alphabetical Order) (see instructions) HAP/TAPS Method Code Efficiency Factor Control
(Pounds/Year) (Net after all controls)
(See Instructions)
2019
Arsenic Compounds -
Arsine gas (Component of 7784-42-1 0.0001 08
ASC)
Benzene 71-43-2 0.0014 08
Beryllium Compound,
Unlisted (Specify & BEC-Other 0 08
Component of BEC)
Cadmium Unlisted CDC-
Compounds (Specify & Other 0.0007 08
Component of CDC)
Chromium Unlisted CRC-
Compounds (Specify & Other 0.0009 08
Component of CRC)
Cobalt Unlisted
COC=
Compound (Specify& 0.0001 08
Component of COC) Other
Manganese Unlisted
MNC-
Compounds (Specify& 0.0002 08
Component of MNC) Other
Mercury Unlisted HGC-
Compounds (Specify& Other 0.0002 08
Component of HGC)
Naphthalene (Component 91-20-3 0.0004 08
of POMTV)
Nickel Unlisted
Compounds (Specify& NIC-Other 0.0014 08
Component of NIC)
Polycyclic Organic Matter
(Inc PAH, dioxins, etc. NC POM 0.0004 08
& AP 42 historic
amorphous glob)
Toluene 108-88-3 0.0022 08
Facility Total CY 2019 Emissions Summary
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
North Carolina Department of Environmental Quality
Division of Air Quality
Air Pollutant Point Source Emissions Inventory-Calendar Year 2019
Record Facility-Wide Totals From all Permitted and Non-Permitted AirPollutant Emission Sources
Green House Gases Pollutants(GHG
Actual Emissions'(Tons/Year)
Pollutant I CAS 12019 2018 1%Change
Criteria Pollutants
Actual Emissions(Tons/Year)
Pollutant CAS 2019 2018 % Change
CO CO 579.34 493.3 17.441727%
NOx NOx 280.04 245.13 14.241425%
PM(TSP) TSP 156.92 131.05 19.740553%
PM 10 PM 10 156.92 130.56 20.18995%
PM2.5 PM2.5 137.44 114.18 20.371346%
S02 S02 13.61 13.75 -1.0181843%
VOC VOC i 2194.46 985.75 122.61831%
Hazardous Air Pollutants RAPS and/or Toxic Air Pollutants TAPS
Actual Emissions(Pounds/Year)
Pollutant I CAS 12019 12018 % Change
Pollutant Group:Arsenic&Compounds(total mass of elemental AS,arsine and all inorganic compounds)Group Sum:.29799
Arsenic Compounds-Arsine gas 7784-42-1 1.0E-4 .0011 -90.909096%
(Component of ASC)
Arsenic Unlisted Compounds( ASC-Other 0.29789 .30594 -2.6312332%
Specify&Component of ASC)
Pollutant Group:Beryllium&compounds(Total mass)Group Sum:.01267
Beryllium Compound,Unlisted BEC-Other 0.0122 .0163 -25.153378%
(Specify&Component of BEC)
Beryllium metal(unreacted) 7440-41-7 4.7E-4 .00291 -83.84879%
(Component of BEC)
Pollutant Group:Cadmium&compounds(total mass inc elemental metal)Group Sum:.43918
Cadmium Metal(elemental 7440-43-9 0.43848 .53403 -17.892258%
unreacted,Component of CDC)
Cadmium Unlisted Compounds I nR n QQ cIA40/
Hexachlorodibenzo-p-dioxin 57653-85-7 0.052 .072 27.777773%
1,2,3,6,7,8(Component of CLDC)
Pollutant Group:Chromium(VI),Non-Specific Compounds,as Chrom(VI)(Component CRC)Group Sum:0.0
Chromium(VI)Non-Specific,
Unlisted(Specify&Component of NSCR6-Other 0.0 Not reported N/A
NSCR6&CRC)
Pollutant Group:Chromium(VI)Soluble-Chromate Compounds(Component of CRC}Group Sum:.00047
Ch SolCR6&CRC)romic acid(VI)(Component of 7738-94-5 4.7E-4 .00291 -83.84879%
Pollutant Group:Chromium 7 All/Total(Inc Chromium(VI)categories,metal and Others)Group Sum:.84981
Chromic acid(VI)(Component of 7738-94-5 4.7E-4 .00291 -83.84879%
SolCR6&CRC)
Chromium.(VI)Non-Specific,
Unlisted(Specify&Component of NSCR6-Other 0.0 Not reported N/A
NSCR6&CRC)
Chromium Unlisted Compounds CRC-Other 0.84934, .8353 1.6808324%
(Specify&Component of CRC)
Pollutant Group:Cobalt compounds Group Sum:.33886
Cobalt Unlisted Compound COC-Other 0.33886 .29622 14.394706%
(Specify&Component of COC)
Pollutant Group:Manganese&compounds Group Sum:23.90239
Manganese Unlisted'Compoundg MNC=Other 23.90239 20.47805 16.721998%
(Specify&Component of MNC) .
Pollutant Group:Mercury&Compounds-all total mass,inc Hg Vapor Group Sum:.32097
Mercury Unlisted Compounds HGC-Other 2.0E-4 .0014 85.71429%
(Specify&Component of HGC)
Mercury,vapor(Component of 7439-97-6 0.32077 .31169 3.1116407%
HGC)
Pollutant Group:Nickel&Compounds,sum total mass,inc elemental Group Sum:2.37521
Nickel Unlisted Compounds(Specify&Com ponent of NIC) NIC-Other 0.0014 .0117 88.03419%
Nickel metal(Component ofNIC) 17440-02-0 12.37381 2.53842 ' -6.484739%
Pollutant Group:Polycyclic Organic Matter(7 PAH Compounds for NIF)Group Sum:1.08504
Benzo(a)pyrene(Component of -50-32-8 F
8504 90115 F2O145%
POMTV&POM7)
Pollutant Group:Polycyclic Organic Matter(Specific Compounds from OAQPS for TV)Group'Sum:30.76125
Benzo(a)pyrene(Component of 50-32-8 1.08504 .90115 20.466145%
POMTV&POM7)
Naphthalene(Component of POMTV) 9.1-20-3 29.67621 26.1092 13.661893%
Acetaldehyde 75-07-0 12367.766 10205.8104 21.183569%.
Acrolein 107-02-8 2279.3342 1870.32563 21.868307%
Benzene 71-43-2 165.72574 141.48751 17.131008% '
Bromine 7726-95-6 16.0 13.38 19.581465%
Chlorine 7782-50-5 552.849 469.035 17.869453%
Chromium(VI)&compounds CHROM6CPDS 0.19 Not reported N/A
Cumene. 98-82-8 1618.62 1268.9 27.560877%
Ethylene dichloride(1,2= 107-06-2 A.949 1.299 -26.943806%
dichloroethane)
Formaldehyde 50-00-0 45013.926 37893.92602 18.789291%
Hexane,n- 110-54-3 586.963 581.934 0.86418587%
Hydrogen chloride(hydrochloric acid) 7647-01-0 1099.371 932.125 17.94244%
•
Methanol 67-56-1 1570093.6 1466116.05504 122.307226%
Methyl isobutyl ketone 108-10-1 243.0 207.02 17.379961%
Methylene chloride 75-09-2 245.452 207.801- 18.1.18778%
Phenol 108-95-2 19265.531 18058.627 6.683256%
Phosphorus Metal,Yellow or 7723-14-0 3.223 4.413 -26.965784%
White
Polycyclic Organic Matter(Inc
PAH,dioxins,etc.NC&AP 42 POM 120.16567 101.05139 18.915405%
historic amorphous glob)
Propionaldehyde 123-38-6 752.001 626.428 20.04588%
Toluene 108-88-3 187.26761 1185.0662 11.189529%
Vinyl chloride 75-01-4 0.602 1.824 -26.941748%
COPY of RECORD Date Submitted: 6/30/2020 09:26:13
As entered in AERO
Facility Name: Arauco North America, Inc. Facility ID : 1900015
985 Corinth Road Permit : 03449
Moncure,NC 27559 County : Chatham
DAQ Region : RRO
Comments From Facility: