Loading...
HomeMy WebLinkAboutAQ_F_0400009_20221206_CMPL_NOV ,p a. 4/, ROY COOPER Governor' ELIZABETH S. B[SEI MICHAEL ABRACZINSKAS N 0 R T H C.ARC-)LiNAA Direct.�r Environmental Quality 6 December 2022 CERTIFIED MAIL RETURN RECIEPT REQUESTED Mr. Charles Horne, President Hornwood Inc. 766 Hailey's Ferry Road Lilesville, NC 28091-9759 Subject: Notice of Violation 15A NCAC 02D .0611 "Condenser/Mist Eliminator Requirements" Hornwood Inc Air Permit 04888R17 Lilesville, NC, Anson County Facility ID No. 04-00009; Fee Category: Small Dear Mr. Horne: On 8 November 2022, Mike Turner and Jeffrey Cole of the Fayetteville Regional Office Division of Air Quality (FRO DAQ) conducted an air quality compliance inspection at the Hornwood, Inc. facility in Lilesville, Anson County, NC. During the inspection, the inspectors noted the Condenser/Mist Eliminator(CS ID No. CD 2) logbook showed there were seven separate entries on 24 October 2022 where the pressure drop across CD-2 was over 8 inches of water. There were also six separate entries on 1 November 2022 where the pressure drop ranged from 8.02 inches of water to 8.9 inches of water. The records over these time periods did not note that any corrective actions were taken by the facility personnel, including implementing wash procedures to clean the filters inside CD-2. Your current permit contains specific condition and limitation A.11, 15A NCAC 02D .0611 — "Condenser/Mist Eliminator Requirements", which states the Permittee shall implement the wash procedure when the pressure drop across the mist eliminator increases to 7.5 to 8.0 inches of water. " Failure to implement the wash procedure when the pressure drop exceeded 7.5 to 8.0 inches of water constitutes violations of 15A NCAC 02D .0611 "Condenser/Mist Eliminator Requirements." As stated in the subject above, this letter represents a Notice of Violation for the cited violations. These violations, and any future violation of an air quality regulation, are subject to the assessment of civil penalties according to North Carolina General Statute 143-215.114A. In addition, each day of continuing violation after written notification from the Division of Air Quality shall be considered a separate offense. Be advised a Notice of Violation letter was issued to Hornwood, Inc. on 26 April 2019 for this same violation. This pattern of failure to comply with applicable air quality regulations is a concern to this office. Please submit a written response, due no later than 20 December 2022, documenting the reasons you violated the above-cited permit requirements, the steps your facility ED` E —' North Cairolinzi Department of Environ ne-�tal Quaiity J Division of,air Qj_�aiity Faycttevillc:Regional Office 22`;Gn?,en Street,Suite i(4 I Fayetteville-North Carolina 28301 Orpartmrnf n4 Environmeolal t?uaEity 910.433,3300 1 j 1:j10.485,/46; F Mr. Charles Horne 6 December 2022 Page 2 has taken or plans to take to ensure future compliance with these requirements, and the date by which you anticipate achieving compliance. The DAQ appreciates your immediate attention to this environmental concern. We strongly recommend that you carefully examine your current air permit. If you have any questions about your permit or the cited violations, please contact Mike Turner, Environmental Specialist, or Stephen Allen, Acting Compliance Coordinator, at (910) 433-3300. Sincere , Heather S. Carter Regional Supervisor Division of Air Quality, NCDEQ HSC/wmt cc: Laserfiche DENorth Carolina Department of Environmental Quality I Division of Air Quality Fayetteville Regional office 225 Green Street,suite 71.1 I Fayetteville,North Carolina 28:301 nepartmmi of FoWo mtttat Qiwtlity 40-o*" 910.433.3300 T 1 910.485.7467 F